1 MEMORANDUM TO: FROM: Susan Thorneloe, EPA Paul Lemieux, EPA Aaron Osborne DATE: November 23, 2004 SUBJECT: Investigation of Previous BDR Disposal Incidents As ERG continues to develop the Building Decontamination Residue Decision Support Tool (BDR DST), we have investigated several previous biological/chemical contamination cleanup efforts to assist in the development of guidance in the event of future decontamination activities. This memorandum summarizes the findings of this investigation applicable to the development of the BDR DST. Five incidents involving biological/chemical contamination are discussed in this memorandum. The incidents were chosen based on availability of applicable information, such as, building decontamination methods, BDR removal techniques, PPE worn during BDR handling, waste classification (e.g., municipal, infectious, hazardous), and any additional information related to worker safety, packaging, storage, and transportation of the BDR. The sources of this information are cited throughout the memorandum. Several key findings of this research are: For the cases examined, BDR was not completely decontaminated prior to removal from the facility. This impacts worker safety concerns during the removal, packaging, storage, and transportation of BDR and influences the waste classification of the BDR for final disposal. Anthrax contaminated wastes were treated as infectious waste, and the associated regulations (DOT, etc.) were applied to the storage, packaging, and shipping of anthrax contaminated wastes. PCB and explosive residue contaminated wastes were classified as hazardous waste, and the associated regulations were applied to storage, packaging, and shipping of these wastes. Note that no case studies were found for the cleanup of facilities contaminated with chemical agents (e.g., VX, mustard). PCB and explosive residue contamination cleanups were used as the best available case studies. While bleach solutions were found to be 100% effective at eliminating anthrax on hard surfaces, neither bleach nor foams were 100% effective at eliminating anthrax in carpet and porous surfaces. Therefore, porous surfaces will be contaminated during the storage, packaging, and shipment.
2 Page 2 Incident #1 Reston Ebola, Reston, VA, 1989 Incident Summary: A research lab was contaminated with the Ebola virus when infected monkeys were imported from the Philippines. The strain of Ebola was later found to be non-infectious to humans. Decontamination Method: The facility was first hosed down with a bleach solution. Later, final decontamination consisted of fumigation with paraformaldehyde at 10,000 ppm for 48 hours. BDR Handling: All straw, bedding, and porous material was removed and sent to incineration. The source was not clear whether this happened prior to bleach decontamination or not. It is clear that this occurred prior to fumigation. PPE: During the decontamination process workers wore (the source does not clearly say what was worn during BDR removal): Green surgical scrubs; Tyvek suits; Triple gloves (one heavy latex glove like those used when washing dishes); Tennis shoes and rubber boots; Clear plastic helmet; and Positive pressure HEPA filtered air supply. After use, PPE was collected as infectious waste, bagged, and shipped for incineration. Workers complained about poor dexterity while trying to perform decontamination activities in this PPE. Shipping Information: Contaminated waste was drenched in bleach and double bagged. The bags were placed in paraffin-impregnated hatboxes. The boxes were double bagged and placed in Styrofoam chests. Lots of absorbent material (e.g., kitty litter) was also placed in the bags and in the hatboxes. Wastewater Disposal: Wastewater from the first decontamination with bleach apparently went down the drain. All drains in the facility were thoroughly drenched with bleach. Wastewater from personnel decontamination was collected and sent for some unknown special treatment. Additional Safety Information: Only two people were allowed in the facility at a time. It took 30 minutes to suit up workers in this level PPE, and approximately the same time to decontaminate them after work. Workers were only allowed to work for one-hour intervals, then they were required to sit down and rest for 30 minutes.
3 Page 3 Sources: U.S. Department of Health and Human Services, Proceedings of the Seminar on Responding to Consequences of Chemical and Biological Terrorism, Bethesda, MD, July 11-14, Alexander, L Decontaminating Civilian Facilities: Biological Agents and Toxins, Institute of Defense Analysis, Alexandria, VA. Incident #2 State Department Mail Facility, Sterling, VA, 2001 Incident Summary: A letter containing anthrax spores contaminated the facility. Two postal workers died from inhalation anthrax. Decontamination Method: Hot spots were first cleaned with a bleach solution, followed by fumigation with vaporized hydrogen peroxide. BDR Handling: Our strategy is to dispose of as much of the contents of the building as possible, thereby significantly reducing the exposed surface area for fumigation. (U.S. Department of State, 2002) BDR items removed included documents, furniture, insulation, and drywall. The BDR removal occurred before hot spots were decontaminated with bleach. Some of the BDR was sent directly to an incinerator in Macon, GA. Other BDR items were sent to an autoclave in Jacksonville, FL, and subsequently landfilled or returned for use. Additional Information: In response to this incident and the release of anthrax at several other facilities, EPA released guidance for these decontamination efforts. The key points from this guidance document are summarized later in this memorandum. Sources: Laris, M Crews Begin Cleanup of State Department Mail Site in Northern Virginia, Washington Post, December 17, U.S. Department of State, Press Releases, Decontamination of Sterling Mail Facility. December 16, Incident #3 Hart Senate Office Building, Washington, DC, 2001 Incident Summary: A letter containing anthrax spores was opened in Senator Tom Daschle s office. The entire building required extensive decontamination.
4 Page 4 Decontamination Method: Hard surfaces were first decontaminated with a bleach solution. The solution was 1 part household bleach, 1 part white vinegar, and 8 parts water. The building was later fumigated with chlorine dioxide gas. Several mailrooms through which the letter was shipped were decontaminated using an anti-bacterial foam. BDR Handling: Moving furniture, papers, and other BDR items around was found to reaerosolize anthrax; therefore, BDR items were removed prior to vapor phase decontamination. However, prior to disposal, BDR items were rinsed with a 500-ppm aqueous chlorine dioxide solution. All BDR was sent to an incinerator. The source indicates that larger items were also incinerated, but does not provide the specific size reduction techniques. PPE: In response to the incident, CDC issued official guidance stating workers performing environmental sampling for anthrax (i.e., testing to see if decontamination was effective) should wear the following PPE: Powered air-purifying respirator with full facepiece and HEPA filter; Disposable PPE with integral hood and bootie; and Disposable gloves made of lightweight nitrile or vinyl so as not to compromise dexterity. After use, PPE was collected and shipped to a medical waste incineration. Wastewater Disposal: Decontamination wastewater was collected and sampled. Even though sampling did not detect anthrax, the water was steam sterilized as a conservative step. The source specifically states that the water was not sent to a POTW for final disposal, but does not state the final destination of the water. Additional Information: In response to this incident and the release of anthrax at several other facilities, EPA released guidance for these decontamination efforts. The key points from this guidance document are summarized later in this memorandum. Sources: Vogt, B. and Sorensen, J How Clean is Safe? Improving the Effectiveness of Decontamination Structures and People Following Chemical and Biological Incidents. Oak Ridge National Laboratory, Oak Ridge, TN. Powell, M Disposal of Wastes From Anthrax Contaminated Sites, HAZWOPER Training, Palm Beach, FL, October 4, 2002.
5 Page 5 Incident #4 Mercury Released in a School, Indiana, 1999 Incident Summary: A student brought 50 cc of mercury to school and played with it throughout the day. Decontamination Method: A commercial vendor preformed the decontamination. The vendor first identified where mercury contamination was located using a field screen with a black light. A substance that absorbs mercury, Mercsorb, was applied to contaminated areas and subsequently vacuumed up. A special powder that turns blue in the presence of mercury was also used to determine if mercury was present in the air. BDR Handling: Books, clothes, and carpet were thrown away prior to decontamination efforts, but other items, such as desks, were decontaminated. PPE: Cleanup personnel wore (the source does not clearly say what was worn during BDR removal): Saranix suits; Booties; Double layered latex gloves; and Respirators. Wastewater Disposal: People were decontaminated over a storm drain. Source: Vogt, B. and Sorensen, J How Clean is Safe? Improving the Effectiveness of Decontamination Structures and People Following Chemical and Biological Incidents. Oak Ridge National Laboratory, Oak Ridge, TN. Incident #5 PCBs Released at the Commerce Building, Washington, DC, 1999 Incident Summary: An electrical surge caused capacitors to leak oil containing PCBs. Parts of the building were closed for three months to clean up the PCBs. Decontamination Method: Absorbent materials were used to collect standing pools of liquid. Surfaces were then decontaminated using solvent (turpentine, PipeX, and MetalX) rinses. BDR Handling: Non-metal items were discarded. Metal items were decontaminated. Additional Information: In response to several other PCB leaks, guidance was released on the PCB decontamination. The key points from this guidance document are summarized later in this memorandum.
6 Page 6 Source: Vogt, B. and Sorensen, J How Clean is Safe? Improving the Effectiveness of Decontamination Structures and People Following Chemical and Biological Incidents. Oak Ridge National Laboratory, Oak Ridge, TN. Guidance Documents on Anthrax Decontamination This information is from the following EPA guidance documents on anthrax decontamination. They were written in response to the anthrax releases at the Hart Senate Office Building and other facilities. Arduino, M. and Sweeney, M., Draft Interim Recommendations for the Cleanup of Commercial and Residential Buildings Following Bacillus anthracis Spore Release. U.S. Environmental Protection Agency. U.S. EPA, Federal Anthrax Decontamination Efforts. Decontamination Method: The following conditions apply to the use of a bleach solution for anthrax decontamination: Only hard surfaces may be treated. A bleach solution close to but not above ph 7 (neutral) and 5,000 to 6,000 parts per million (ppm) should be prepared by mixing one part bleach (5.25%-6.00%) to one part white vinegar to eight parts water. Bleach and vinegar must not be combined together directly; rather some water must first be added to the bleach (e.g., two cups water to one cup of bleach), then vinegar (e.g., one cup), and then the rest of the water (e.g., six cups). The ph of the solution should be tested with a paper test strip. Treated surfaces must remain in contact with the bleach solution for 60 minutes (repeated applications will be necessary to keep the surfaces wet). (U.S. EPA, 2004.) BDR Handling: Porous surfaces (carpets, drapes, ceiling tiles, wallpaper) can be treated with bleach solutions to decrease spore count, but must be removed and properly discarded after treatment, because decontamination methods are not 100% effective on porous BDR. Anthrax contaminated solid and liquid wastes must be handled in a manner no less stringent than as medical waste. Disposal of porous items should only occur after a personnel decontamination station has been established. This implies that workers disposing of BDR will be wearing extensive PPE.
7 Page 7 Because dirt and other material on a surface will decrease the efficiency of decontamination agents, all surfaces should be precleaned with a surfactant prior to decontamination. Similar to asbestos abatement, strategies must be developed for the minimization of anthrax aerosolization: Do not use compressed air for cleaning; Only use wet operations or HEPA filters; and Do not dry sweep or dry dust. Objects with internal cooling fans (computers) may be a contamination concern, and should be specially treated for decontamination or disposal PPE: PPE should be selected based on HAZWOPER standards. Contaminated clothing and PPE must be either disposed of as pathological waste or sent to an autoclave. People cleaning areas adjacent to, but not identified as contaminated with anthrax, should wear the following PPE: Filtering full face piece respirator (N-95); and Nitrile or vinyl gloves. Packaging, Storage, and Transportation: Wastes must be: DOT Division 6.2 (Infectious Substances) requirements should be followed for the packaging of anthrax contaminated wastes. For storage, wastes must be: Properly packaged; Protected from weather; Protected from unauthorized human access; Protected from vermin access; and Stored in a manner following any state specific regulations, such as, time limits. DOT Hazardous Materials Regulations (49 CFR ) should be followed to the transportation of anthrax contaminated wastes. Additional Information: All HAZWOPER standards apply, including: Health and safety plan development; Medical surveillance; PPE program; and Appropriate training. The contaminated area should be sealed the same way an asbestos abatement area would be sealed.
8 Page 8 All ducts should be tested for contamination. Decontaminating vents may be especially difficult if they are lined with fiberglass. Waste packaging fell under DOT Division 6.2 (Infectious Substances) requirements Transportation fell under DOT Hazardous Materials Regulations (49 CFR ) Guidance Document on PCB Decontamination - This information is from the Mitchel report document written in response to several PCB contamination incidents. Hazardous contamination levels were taken from OSHA s website. Mitchel, Scadden, and Weston. PCB Decontamination Methods for Achieving TSCA Compliance During Facility Decommissioning Projects. NDIA Environmental Symposium and Exhibition, Austin, TX, April 25, OSHA, Chemical Agent Multi Media/Toxicity Table. Decontamination Method: PCB contaminated materials can be decontaminated using double wash-rinses with solvents. BDR Handling: The easiest and most cost effective way to dispose of porous surfaces contaminated with PCB is disposal as hazardous waste. Decontamination is difficult and more expensive. Materials containing less than 50 mg of PCB/kg of bulk media and less than 10- micrograms of PCB/100 cm 2 of exterior surface can be disposed of in a regular municipal landfill. Above these concentrations, BDR items must be treated as hazardous waste. Similar hazardous contamination levels have been developed by DOD for several chemical agents. The following are maximum concentrations for disposal at a nonhazardous waste facility: Mustard 0.3 mg/kg GA 68 mg/kg GB 32 mg/kg GD/GF 5.2 mg/kg VX 1.1 mg/kg Lewisite 3.7 mg/kg
9 Page 9 Guidance Document on Explosive and Chemical Agent Disposal The following information is from the Navy s guidance document on the disposal and decontamination of explosives and chemical agents. Naval Sea System Command (NAVSEA), Ammunition and Explosive Safety Ashore, OP 5, Revision 7, Change 3. BDR Handling: M8 Chemical Test Strips may be used to determine if an item is contaminated with a chemical agent. Contaminated BDR should be treated as hazardous waste in accordance with all applicable regulations. Packaging, Storage, and Transportation: A fence should be placed around the storage facility at a minimum of 30 feet from the facility. All items should be properly tagged, including its type and degree of contamination and appropriate handling restrictions. Extensive information on shipping regulations for explosives are also contained in the manual, similar to DOT regulations. Wastewater Disposal: Discharging ammunition or material contaminated with explosive or chemical agents into watersheds, sewers, streams, lakes, or waterways is prohibited.
Guidelines for Collecting Qualitative Environmental Samples of Anthrax
Guidelines for Collecting Qualitative Environmental Samples of Anthrax Adapted from Centers for Disease Control Procedures for Collecting Environmental Samples of Anthrax (October 23, 2001 draft) Maryland
More informationMold Remediation. 1. Purpose and Requirements. 2. Scope. 3. General Responsibilities HS13_IAQ_SOP_002. Occupational Safety & Health
Occupational Safety & Health HS13_IAQ_SOP_002 1. Purpose and Requirements When mold growth occurs indoors, adverse health problems may be reported by some building occupants, particularly those with allergies
More informationMold Remediation. Containment guidelines: based on the size of the infected area.
Mold Remediation Containment guidelines: based on the size of the infected area. Level 1 (10 sq. ft. or less): e.g. ceiling tiles, small areas on walls Moldy materials that can be cleaned should be cleaned
More informationBP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8
Safety Manual Page 1 of 8 1. Purpose This policy assists in protecting USPL workers from exposure to lead and to gain compliance with state and federal regulations. 2. Scope The OSHA requirements and this
More informationBP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8
BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8 1. Purpose This policy assists in protecting USPL workers from exposure to lead and to gain compliance with state and federal regulations.
More informationWork Plan for Window Removal and Remediation Rooms: 200 Wing classrooms, Cafeteria and Kitchen Thomas Prince School Princeton, Massachusetts
1) Introduction Work Plan for Window Removal and Remediation Rooms: 200 Wing classrooms, Cafeteria and Kitchen Thomas Prince School Princeton, Massachusetts Triumvirate Environmental Inc. (TEI) shall perform
More informationSTANDARD OPERATING PROCEDURES FOR MOLD REMEDIATION
West Virginia University Environmental Health and Safety STANDARD OPERATING PROCEDURES FOR MOLD REMEDIATION Revised February 2016 West Virginia University P.O Box 6551 Morgantown WV 26506 # 304-293-3792
More informationStandard Operating Procedure PCB Fluorescent Light Ballast Management
Page # 1 of 5 Implementation SOP Owner Devlin Piplic Approval Standard Operating Procedure PCB Management 1. Purpose This Standard Operating Procedure (SOP) outlines the work instructions for the handling
More informationDUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM
DUQUESNE UNIVERSITY ASBESTOS OPERATIONS & MAINTENANCE PROGRAM Revised January 2017 Prepared by: Environmental Health and Safety Department TABLE OF CONTENTS Page Introduction 1 Scope 1 Policy Statement
More informationSUNY Interim Guidance on Ebola Cleaning and Disinfection for Non-Healthcare and Non-Laboratory Settings
EBOLA VIRUS ENVIRONMENTAL CLEANING AND DISINFECTION FOR NON-HEALTHCARE AND NON-LABORATORY SETTINGS REFERENCES: NYSDOH Guidance for Local Health Departments on Ebola Virus Environmental Cleaning and Disinfection
More informationBiological and Regulated Medical Waste Plan
Biological and Regulated Medical Waste Plan TUFTS ENVIRONMENTAL HEALTH AND SAFETY OCTOBER 2016 Table of Contents I. Purpose... 3 II. Responsibilities... 3 III. Sink and sewer discharge of specific medical
More informationGUIDELINES FOR TRANSPORTING ANTHRAX AND ANTHRAX-CONTAMINATED OBJECTS AND MATERIALS
RESEARCH AND SPECIAL PROGRAMS ADMINISTRATION GUIDELINES FOR TRANSPORTING ANTHRAX AND ANTHRAX-CONTAMINATED OBJECTS AND MATERIALS What regulations apply to the transportation of anthrax and other infectious
More informationUniversity of Toronto Asbestos Management Program PROCEDURAL CHECKLIST FOR TYPE 1 ASBESTOS ACTIVITIES
University of Toronto Asbestos Management Program PROCEDURAL CHECKLIST FOR TYPE 1 ASBESTOS ACTIVITIES Project Description: Date Work Conducted: Completed by: (Name and Dept) NOTIFICATION/AWARENESS: 1.
More informationCHAPTER 9. Emergency Response. Chapter 9. National Pesticide Applicator Certification Core Manual
CHAPTER 9 Emergency Response Chapter 9 National Pesticide Applicator Certification Core Manual CHAPTER 9 Emergency Response This module will help you: Know how to implement and execute an emergency response
More informationPIGEON DROPPINGS CLEAN UP WORK TABLE OF CONTENTS
PIGEON DROPPINGS CLEAN UP WORK TABLE OF CONTENTS PAGE PIGEON DROPPINGS CLEAN UP WORK... 1 1 GENERAL... 1 1.1 GENERAL CONDITIONS AND RELATED WORK... 1 1.2 DESCRIPTION OF WORK... 1 1.3 DOCUMENTS TO BE SUBMITTED...
More informationTechnical Issues Associated with Treatment of Ebola Virus- Contaminated Waste
Technical Issues Associated with Treatment of Ebola Virus- Contaminated Waste P. Lemieux and J. Wood US EPA Presentation for Research Priorities to Inform Public Health and Medical Practice for Domestic
More informationFlood / Mold Remediation (FMR) 29 CFR
Flood / Mold Remediation (FMR) 29 CFR 1910.141 METHODIST UNIVERSITY Environmental Health and Safety Office Flood / Mold Remediation (FMR) 29 CFR 1910.141 OSHA Workplace Sanitation and Health Hazards Revision
More informationPCBs in Building Materials. John Gorman Jim Haklar USEPA
PCBs in Building Materials John Gorman Jim Haklar USEPA PCBs in Building Materials What are PCBs Sources of PCBs in Building Materials Regulatory Requirements Levels of PCBs Found Removal & Clean-up Standards
More informationUNIVERSITY OF TOLEDO
UNIVERSITY OF TOLEDO SUBJECT: MOLD PREVENTION AND REMEDIATION Procedure No: HM-08-035 PROCEDURE STATEMENT In accordance with guidance provided by the US Environmental Protection Agency (EPA), Centers for
More informationPROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA
The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending
More informationAsbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Materials
Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Materials Revised November 21, 2013 Application Code of Practice Where asbestos is present or believed to be present in a workplace
More informationCertification Number: NAT Lead Renovation, Repair and Painting Program
Certification Number: NAT-117534-2 Lead Renovation, Repair and Painting Program August 2018 Lead Renovation, Repair and Painting Program TABLE of CONTENTS I. Purpose II. Risk Identification III. Responsibilities
More informationComprehensive Procedures for Collecting Environmental Samples for Culturing Bacillus anthracis Revised April 2002
Comprehensive Procedures for Collecting Environmental Samples for Culturing Bacillus anthracis Preface Environmental sampling to determine the presence of Bacillus anthracis spores in indoor environments
More informationSAFE WORK PROCEDURE LOCATION WRITTEN BY: APPROVED BY: DATE CREATED LAST REVISION. Schools in PTSD Lorie Carriere School Principal August 30, 2011 New
Page 1 of 6 LOCATION WRITTEN BY: APPROVED BY: DATE CREATED LAST REVISION Schools in PTSD Lorie Carriere School Principal August 30, 2011 New PERSONAL PROTECTION EQUIPMENT (PPE) Safety glasses or face shield
More informationBelmont University Universal Waste Policy
Purpose: Belmont University Universal Waste Policy Universal Wastes are specific categories of common Hazardous Wastes that are regulated so that management of those items is less burdensome. None of the
More informationAsbestos Abatement Standard Procedures Indoor Environment Group, Inc.
The following work procedures are specified on all full containment asbestos abatement projects that we design. A. Preliminary Air Sampling: Many buildings contain background fiber levels prior to, or
More informationSafety Data Sheet 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Safety Data Sheet 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: CS-177 Quaternary Ammonium Disinfectant Manufacturer: Issue Date: February 215 6429 West Jones Avenue P.O. Box 81 Zellwood,
More informationSafe Pesticide Practices
Agricultural Extension Service The University of Tennessee PB654 Safe Pesticide Practices Safe Pesticide Practices Gene Burgess, Professor Entomology & Plant Pathology Safe use of pesticides is everyone
More informationAnimal cell and tissue culture. Lab 1
Animal cell and tissue culture Lab 1 Tissue culture Laboratory Safety Outline Lab Safety Biohazards Biosafety Levels Biosafety Cabinets Decontamination Biological Waste Introduction A cell culture laboratory
More informationBayer Environmental Science
Revision Date: 06/01/2010 SECTION 1. CHEMICAL PRODUCT AND COMPANY INFORMATION Product name NORTICA MSDS Number 102000023882 EPA Registration No. 432-1512 Bayer Environmental Science 2 T.W. Alexander Drive
More informationINTRODUCTION TO THE PROGRAM
INTRODUCTION TO THE PROGRAM Structure and Organization Information in this program is presented in a definite order, so that employees will see the relationships between the various groups of information
More informationTexas A&M University Commerce April 11, 2014
Laboratory Biosafety Texas A&M University Commerce April 11, 2014 Bruce Whitney, Ph.D. Chief Research Compliance Officer brucewhitney@tamus.edu Laboratory Biosafety Development of Biosafety Practices Biological
More informationOur Job: Prevent dis-ease as well as disease
Our Job: Prevent dis-ease as well as disease 1 Kansas Ebola Virus Preparedness and Response Plan: Revised 15 October 2014 2 Background and Situation Update 3 West Africa (As of 12 October 2014) Total Cases
More information_KleenGrow_ _1_81820_.pdf
81820-2 20180321_1_81820_.pdf Plants, Cut Flowers, Nursery Stock in Greenhouses and in Irrigation Lines. Hard, Non-Porous Surfaces in Greenhouses, Storage Barns and Coolers. Didecyl dimethyl ammonium chloride...
More informationStandard Operating Procedure Safe Autoclave Operations
Standard Operating Procedure Safe Autoclave Operations The purpose of this instructional document is to introduce and familiarize the reader to the standard operating procedures for the safe use of autoclaves.
More informationDetermination of Clearance Criteria Following Mercury Decontamination Projects
Determination of Clearance Criteria Following Mercury Decontamination Projects PO-115 American Industrial Hygiene Conference and Exposition May 13-16, 2006 David Regelbrugge, CIH, CSP Gary N. Crawford,
More information"ASBESTOS AWARENESS IN THE WORKPLACE"
MAJOR PROGRAM POINTS "ASBESTOS AWARENESS IN THE WORKPLACE" Training For THE OSHA ASBESTOS STANDARD Quality Safety and Health Products, for Today...and Tomorrow Outline of Major Points Covered in the "Asbestos
More informationProject 6668 Second beach Concession-Stanley Park Drive,Vancouver, BC Division 02080
PART 1 GENERAL 1.0 Instructions To Bidders Hazardous Materials Contractors are responsible for the information as provided in the City of Vancouver Invitation to Tender including all available documents,
More informationSECTION 1 IDENTIFICATION SECTION 2 HAZARD(S) SECTION 3 COMPOSITION. Ascent Battery Supply, LLC 1325 Walnut Ridge Drive Hartland, WI 53029
SAFETY DATA SHEET (SDS) Ascent Battery Supply, LLC 1325 Walnut Ridge Drive Hartland, WI 53029 LITHIUM THIONYL CHLORIDE The information and recommendations below are believed to be accurate at the date
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET 1. CHEMICAL PRODUCT AND COMPANY INFORMATION Product Name: HEAT TRANSFER 21 Manufacturer Information: Product Use: Holly Refining & Marketing Tulsa, LLC 1700 South Union Ave.
More informationENVIRONMENTAL MANAGEMENT GUIDE FOR SMALL LABORATORIES
United States Office of the EPA 233-B-00-001 Environmental Protection Administrator May 2000 Agency (2131) ENVIRONMENTAL MANAGEMENT GUIDE FOR SMALL LABORATORIES 3.5 Biologically Active Substances and Wastes
More informationInspection Checklist for NIH BL3 Laboratories (7 CFR 331; 9 CFR 121; 42 CFR 73; NIH Guidelines)
12(a) 12(a) 12(b) 12 (c)(3) An individual or entity required to register under this part must develop and implement a written biosafety plan that is commensurate with the risk of the agent or toxin, given
More informationUNIVERSITY OF ROCHESTER MEDICAL CENTER
Date:06 March 2006 Author: Shelley Secor-Socha Principle Investigator: Sally Quataert Approval: 1. General Information Staphylococcal Enterotoxin (SEB) is a single polypeptide chain containing 239 amino
More informationWHO NEEDS TO KNOW THIS PROGRAM All NYU employees that generate, handle or transport RMW should be familiar with this written program.
Title: NYU Regulated Medical Waste Safety Written Program Effective Date: October 2002 Revision Date: April 14, 2017 Issuing Authority: Responsible Officer: VP, Facilities and Construction Management Director
More informationedna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015
edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015 MATERIALS 1. Cellulose nitrate disposable filter funnels or other field-tested,
More information2. Points of Contact Site Superintendent John Strickland
ENVIRONMENTAL PROTECTION PLAN N69450-08-D-1781/004 REPAIR FRC BUILDING 1553 MAYPORT NAVAL STATION, FLORIDA Revision 02 8/19/2010 SLONE ASSOCIATES, INC. 835 GIL HARBIN INDUSTRIAL BLVD. VALDOSTA, GEORGIA
More informationChemical Spill Response Guide. INDIANA UNIVERSITY Office of Environmental, Health, and Safety
Chemical Spill Response Guide INDIANA UNIVERSITY Office of Environmental, Health, and Safety EMERGENCY PHONE NUMBERS Police Department (IUPD).. 911 Fire Department....... 911 Ambulance... 911 NON-EMERGENCY
More informationLABORATORY WASTE DISPOSAL GUIDE
LABORATORY WASTE DISPOSAL GUIDE Purpose This guide will help lab members properly identify and manage hazardous waste in their laboratory. Identifying the types of waste generated is crucial to handling
More informationAppendix C. Yes obtain containment compatible with chemical
Appendix C Chemical Hazard Assessment Form Complete and attach a Chemical Hazard Assessment form for EACH hazardous chemical listed in the SOP. Chemical/ Reagent: Formaldehyde solutions/ Formalin CAS#:
More informationNAVSEA STANDARD ITEM. 1.1 Title: Asbestos-Containing Material (ACM); control
NAVSEA STANDARD ITEM ITEM NO: 009-10 DATE: 18 NOV 2016 CATEGORY: I 1. SCOPE: 1.1 Title: Asbestos-Containing Material (ACM); control 2. REFERENCES: 2.1 29 CFR 1915.1001, Occupational Safety and Health Standards
More informationAsbestos Management Program
Oct. 10/06 Oct 10/06 1/13 Table of Contents 1 INTRODUCTION...2 2 PURPOSE...2 3 SCOPE...2 4 ROLES & RESPONSIBILITIES...2 5 INVENTORY...6 6 ACCESS CONTROL...6 7 INSPECTION...6 8 CLASSIFICATIONS OF ASBESTOS
More information1. PRODUCT AND COMPANY IDENTIFICATION. : Product Stewardship (770)
Page 1 of 6 1. PRODUCT AND COMPANY IDENTIFICATION POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship (770) 271-5902 : CHEMTREC
More informationNARRICOT INDUSTRIES, LP MATERIAL SAFETY DATA SHEET
Product Name: NYLON TAPE & WEBBINGS Page 1/6 NARRICOT INDUSTRIES, LP MATERIAL SAFETY DATA SHEET 1. PRODUCT AND COMPANY IDENTIFICATION Product Name: NYLON TAPES AND WEBBINGS Reference Number: NI 1002 Date:
More informationMaterial Safety Data Sheet
Trade name Manufacturer Validation date Print date Responsible name In case of emergency Material Safety Data Sheet Section 1. Chemical product and company identification Anhydrous Ammonia MSDS Yara North
More information2b Product description Black irregular pieces with little or no odor.
Safety Data Sheet Product Names: AGC-30-D, AGC-30 AD, AGC-30 AW, AGC-30 W AGC-40-D, AGC-40 AD, AGC-40 AW, AGC-40 W AGC-50-D, AGC-50 AD, AGC-50 AW, AGC-50 W, AGC-40-MG (Granular Activated Carbon) Effective
More informationGlyphosate Technical
1. Chemical Product and Company Identification Product Name Formula : : C 3 H 8 NO 5 P Molecuar Weight : 169.1 Chemical Name Manufacturer : N-Phosphonomethyl glycine : Excel Crop Care Limited 184 / 87,
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET 1. CHEMICAL PRODUCT AND COMPANY INFORMATION Product Name: SN 600 4823-00 SN 700 3569-00 SN 750 3568-00 SN 850 4840-00 Manufacturer Information: Marketer Information: Product
More information2b Product description Black irregular pieces with little or no odor.
Safety Data Sheet Product Names: AGC-30-D, AGC-30 AD, AGC-30 AW, AGC-30 W AGC-40-D, AGC-40 AD, AGC-40 AW, AGC-40 HP, AGC-40 W AGC-50-D, AGC-50 AD, AGC-50 AW, AGC-50 W, AGC-40-MG (Granular Activated Carbon)
More informationMaterial Safety Data Sheet BAQUACIL DE/Cartridge Filter Cleaner
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION Material Name : Product Code : MSDS Number : 150000020147 Company : Arch Chemicals, Inc. 501 Merritt 7 PO Box 5204 Norwalk, CT 06856-5204 Telephone : 1-800-511-MSDS
More informationPost Abatement Project Report - Sample Draft Form:
Post Abatement Project Report - Sample Draft Form: 3701-3215 (B) (B) Each lead abatement contractor or lead abatement project designer shall issue a report for each lead abatement project performed. The
More informationImidacloprid Technical
1. Chemical Product and Company Identification Product Name : Formula : C 9 H 10 ClN 5 O 2 Molecuar Weight : 255.7 Chemical Name Manufacturer : 1-[(6-chloro-3-pyridinyl)methyl]-N-nitro-2-imidazolidinimine
More informationSTANDARD OPERATING PROCEDURES SOP: 1502 PAGE: 1 of 11 REV: 0.0 DATE: 10/24/94
PAGE: 1 of 11 1.0 OBJECTIVE 2.0 APPLICABILITY 3.0 DESCRIPTION 3.1 Protective Clothing and Restricted Areas 3.1.1 Protective Clothing 3.1.2 Entry and Exit Procedures CONTENTS 3.2 Sample Receipt and Handling
More informationSafe Disposal of Secondary Waste
Safe Disposal of Secondary Waste The U.S. Army Chemical Materials Agency (CMA) works with federal and state environmental regulators to dispose of chemical weapons safely. An important part of CMA s work
More informationPESTICIDE TRANSPORTATION, STORAGE AND FIRE PREVENTION
PESTICIDE TRANSPORTATION, STORAGE AND FIRE PREVENTION Pesticides Fact Sheet January 1999 Richard Beard, Extension Machinery & Equipment Specialist Howard M. Deer, Extension Pesticide Specialist Utah State
More informationEMERGENCY PHONE: or (651) (24 hours)
Material Safety Data Sheet Copyright, 2009, 3M Company. All rights reserved. Copying and/or downloading of this information for the purpose of properly utilizing 3M products is allowed provided that: (1)
More informationMaterial Safety Data Sheet
Material Safety Data Sheet Page 1 Issued: 07/29/09 Revision No: 2 (MonoFoil Technology Typical Application Strength) Revision Date: 07/29/2009 (Typical Application Strength using 2.0% MonoFoil Antimicrobial)
More informationENVIRONMENTAL HEALTH & SAFETY
ENVIRONMENTAL HEALTH & SAFETY Standard Operating Procedures for Safe Autoclave Operations The purpose of this document is to provide standard operating procedures for the safe use of autoclaves. Autoclaving
More informationGeneral Health and Safety Considerations
Participant Guide Module 7 General Health and Safety Considerations Module Objective Upon the completion of this module, participants should be able to determine the potential spill control methods, proper
More informationMcCabe Gasoline Level Indicator Paste. Safety Data Sheet
Product Identifier Trade Name: Item Number(s): MC 200 Relevant Identified Uses of the Substance or Mixture: Detects gasoline and other light hydrocarbon levels in storage tanks. Date Prepared: April 1,
More informationSafety Data Sheet 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION
Safety Data Sheet 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: CS-424 Low Foam Alkaline Detergent Manufacturer: Issue Date: February 2015 6429 West Jones Avenue P.O. Box 810 Zellwood, FL
More information1. PRODUCT AND COMPANY IDENTIFICATION. : Product Stewardship (770)
Page 1 of 6 1. PRODUCT AND COMPANY IDENTIFICATION 33587 Walker Road, Avon Lake, OH 44012 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship (770) 271-5902 : CHEMTREC 1-800-424-9300
More informationASBESTOS SCIENCE TECHNOLOGIES, INC.
ASBESTOS SCIENCE TECHNOLOGIES, INC. P.O. Box 505 Bangor, CA 95914 Phone (530) 518-0934 Email - astinc17@yahoo.com Report for Trinity Valley Elem. School Willow Creek, Ca. Mold Report - Rooms 12 through
More informationMaterial Safety Data Sheet. MSDS Prepared by: 3form Technical Support and Product Development, 3form, Salt Lake City, UT 84119
Material Safety Data Sheet Revision Date: 11/9/06 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: 3form Varia made with ecoresin Manufacturer/Supplier: 3form, Salt Lake City, UT 84119 MSDS
More informationMSDS (Material Safety Data Sheet)
MSDS (Material Safety Data Sheet) SECTION #1 PRODUCT AND COMPANY IDENTIFICATION TRADE NAME: NEVASTANE GREASE 5 P 7 CHEMICAL NAME AND SYNONYMS: MANUFACTURER/SUPPLIER S NAME: MIXTURE TOTAL LUBRICANTS CANADA
More information1. PRODUCT AND COMPANY IDENTIFICATION 2. COMPOSITION/INFORMATION ON REGULATED INGREDIENTS. Components CAS-No. Weight % Titanium dioxide
Page 1 of 6 POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 1. PRODUCT AND COMPANY IDENTIFICATION Telephone : Product Stewardship (770) 271-5902 Emergency telephone : CHEMTREC 1-800-424-9300
More informationGUIDELINES FOR LABORATORY USE OF CHEMICAL CARCINOGENS
GUIDELINES FOR LABORATORY USE OF CHEMICAL CARCINOGENS UNIVERSITY RISK MANAGEMENT Occupational Safety and Health Programs 19 Hagood Avenue, Suite 908 Charleston SC 29425 843-792-3604 Revised: January 2015
More informationAPPE NDIX F TY PE 2 ASBE STOS WORK PROCEDURES
APPE NDIX F TY PE 2 ASBE STOS WORK PROCEDURES TY PE 2 WOR K PR OCE DUR ES These procedures are to be followed by all maintenance personnel and contractors performing the following work at KPDSB buildings.
More informationSafe Use of Hazardous Materials
Annual Continuing Education Modules Safe Use of Hazardous Materials Safety This self-directed learning module contains information you are expected to know to protect yourself, our patients, and our guests.
More informationDeveloped and Presented by: Wisconsin Healthcare Engineering Association
Infection Control Risk Assessment (ICRA) Developed and Presented by: Wisconsin Healthcare Engineering Association What is an ICRA? An Infection Control Risk Assessment is a tool devised to protect patients
More information200CPEN PANTONE(R) 200 C SIMULATION
Page 1 of 6 1. PRODUCT AND COMPANY IDENTIFICATION POLYONE CORPORATION 2700 Papin Street, St. Louis, MO 63103 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship, (314) 771-1800 : CHEMTREC
More informationFor the Protection of Field and Sweet Corn Seed to discourage consumption by Black Birds Species and Crows. OTHER INGREDIENTS. 2.
24(c) Special Local Need Registration SLN VA 120001 (For Distribution and Use Only Within the State of Virginia) This SLN expires and must not be used or distributed after July 1, 2020 Avipel Hopper Box
More informationMaterial Safety Data Sheet
Material Safety Data Sheet 1. CHEMICAL PRODUCT & COMPANY IDENTIFICATION Page: 1 24-Hour Emergency Phone Number: 989-636-4400 The Dow Chemical Company, Midland, MI 48674 Customer Information Center: 800-258-2436
More informationMaterial Safety Data Sheet. CHEMTREC (24 Hrs) at 1 (800) United States, Canada, Puerto Rico, and Virgin Islands
NAPCO CHEMICAL COMPANY, INC. Water and Wastewater Treatment Chemicals * Feed Systems * Test Kits P.O. Box 1239 Spring, TX 77383-1239 * (281)651-6800 * 1 (800) 929-5976 Revision Date: June 13, 2012 1. PRODUCT
More informationPROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA
The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending
More informationVersion 3.0 Print Date 10/01/2012 Revision Date 09/13/2012 MSDS Number SITE_FORM Number
1. PRODUCT AND COMPANY IDENTIFICATION Product information Trade name : Use of the : Drain Cleaner Substance/Mixture Company : S.C. Johnson & Son, Inc. 1525 Howe Street Racine WI 53403-2236 Emergency telephone
More informationHazard Waste Management Training. This training is a one-time requirement for personnel generating waste at WCU
Hazard Waste Management Training This training is a one-time requirement for personnel generating waste at WCU Hazard Waste Compliance WCU is classified as a hazardous waste generator by the U.S. Environmental
More informationBiosafety Checklist. 07-BiosafetyChecklist-LTC-SOP-v2.0-17Feb of 6
Title: Biosafety Checklist Origination Date: 31 Jan 1997 Total Pages: 5 Effective Date: 17 Feb 2012 SOP Number LTC-SOP-07 v2.0 Supersedes SOP Written By: ACTG/IMPAACT Lab Tech Committee Dated: 01 Jun 2004
More informationBASF Corporation Title: ASBESTOS HANDLING, REMOVAL AND DEMOLITION
Procedure No.: IH-6 Page: 1 of 16 Preparer: Owner: Approver: RECORD OF REVISIONS Date Details of Change 11/02/01 Added a Record of Revisions table. 08/14/08 Review of entire procedure. Deleted 4.3.3 and
More informationInspection Checklist for BSL-3 Laboratories Non-Smile Resource
SMILE Johns Hopkins University Baltimore, MD USA Inspection Checklist for BSL-3 Laboratories Non-Smile Resource Author: CDC.gov Document Number: Fac1.0-19 Effective (or Post) Date: 17 February 2009 Document
More informationProject 6668 Kerrisdale Senoirs Centre-5851 West Boulevard,Vancouver, BC Division 02080
PART 1 GENERAL 1.0 Instructions To Bidders Hazardous Materials Contractors are responsible for the information as provided in the Invitation to Tender including all available documents, meeting minutes,
More information1. PRODUCT AND COMPANY IDENTIFICATION
Page 1 of 7 POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 1. PRODUCT AND COMPANY IDENTIFICATION Telephone : 1 (440) 930-1000 or 1 (866) POLYONE Emergency telephone : CHEMTREC 1-800-424-9300
More informationSafety Data Sheet. In Case of Emergency Call: CHEMTREC or (24 Hours/Day, 7 Days/Week)
Safety Data Sheet Charcoal, Activated, Powder, Darco G60 1. PRODUCT AND COMPANY IDENTIFICATION Product Name: Charcoal, Activated, Powder, Darco G60 Synonyms/Generic Names: Product Number: 1340 Product
More informationTEAL PEARL (Q )
Page 1 of 5 1. PRODUCT AND COMPANY IDENTIFICATION POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship (770) 271-5902 : CHEMTREC
More informationGraphite Engineered Solutions
1. Product and Company Identification: Product Name Product Number Brand Supplier : WonderFill : ALL Grades : Graphite Engineered Solutions Llc. : Graphite Engineered Solutions Llc. 139 Tibert Rd. Columbus,
More informationSAFETY DATA SHEET Trade Name: InstaCote CC LV Fix. Section 1 Product and company identification:
SAFETY DATA SHEET Trade Name: InstaCote Section 1 Product and company identification: Product Name: Manufactured by: Validation date: InstaCote, Vinyl Latex/modified Poly Acrylate Coating Low Viscosity
More informationPANTONE 365U
Page 1 of 6 1. PRODUCT AND COMPANY IDENTIFICATION POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship (770) 271-5902 : CHEMTREC
More informationUNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES
UNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES October 2016 Table of Contents Section Page I. Introduction.... 1 II. Characteristics of Regulated Medical Waste 1-2 III. Exclusions...2-3
More informationDecember 2009 CDC-NIH
December 00 CDC-NIH Guidelines for Biosafety Laboratory Competency, CDC and the Assocation of Public Health Laboratories, CDC MMWR Supplement/Vol. 60 April, 0 PI: BSL BMBL th Edition CDC-NIH Dec. 00 N/A
More information1. PRODUCT AND COMPANY IDENTIFICATION
Page 1 of 6 15 Corporate Drive, North Haven, CT 06473 1. PRODUCT AND COMPANY IDENTIFICATION Telephone : 1 (440) 930-1000 or 1 (866) POLYONE Emergency telephone : CHEMTREC 1-800-424-9300 (24hrs for spill,
More informationLaboratory Close-Out Guidelines
Office of Laboratory Safety 2300 I Street, NW Ross Hall, Suite B- 05 Washington, DC 20037 t. 202-994- 8258 I labsafety@gwu.edu Guidelines The Principal Investigator (PI) is responsible for leaving laboratories
More information