1 Checklist of Common Critical Data Issues: EPA s Hazardous Air Pollutants for Coal- and Oil-fired Electric Utility Steam Generating Units Information Collection Request This document contains a checklist of common "critical" errors in sampling/analytical procedures and electronic data entry observed by EPRI. Critical errors are those that EPRI estimates will have a significant negative impact on the quality or usability of the data. For power plants participating in the EPRI data review, respondents should review this checklist before sending files. This will allow EPRI to put resources to the best use and improve the overall quality of the ICR data. The checklist may be updated as new findings are noted. Checklist of s: ICR Electronic Reporting ERT: will not calculate emissions in Each file should be checked using the EPA s ERT application. This behavior is often due to one of lb/mmbtu or will not print a Test Report the following: Methods, locations, runs or parameters without an associated emissions value SCC code not entered File size too large - EPA has requested that test report and other supporting information not be attached to the ERT but uploaded separately. For Method 10 and 25A data, it is necessary to add ppm units to the method setup in order for the ERT to properly calculate lb/mmbtu. On the ERT- Main Menu, select Locations/Methods under the Setup/Test Plan module. In Section 7b, click Add Emissions/Concentrations. In the pull-down menu at the top of the dialog box, select the method for which you d like to add an emission concentration. Then, click the << button. Select ppm from the menu on the left and click >. Click the Save Selected Items button to close out of the window and save your changes. If these items are fixed and the Test Report still will not print, contact EPA for assistance. ERT: incorrect detection limit format entered The correct format is a numerical value representing the detection limit. No data quality flags or in Emissions field other text characters should be in this field. For each emission value, a detection flag should be entered in the Flag field (see next item). ERT: contents of Flag field differ from EPA The Flag field should contain one of the following for every emission value: ADL, BDL, or DLL. requirements Check that all detection flags are assigned correctly. DLL indicates a multi-fraction method in which one fraction is above the detection limit and the other fraction is below detection limit. No other text should go in the Flag field! The only exception is for Method 23 dioxin/furan/pcb values that the lab has identified as EMPC. EPA has provided guidance to leave the Flag field empty, and enter EMPC in the Comment field.

2 ERT: incorrect detection limit entries for In the Comments field, list each individual fraction in brackets using the format [##] (if above multi-fraction methods (e.g., metals by detection limit) or [<##] (if below detection limit). Sum the detected values and detection limits to Method 29) obtain the value entered into the Emissions field. ERT: errors in emissions calculations Check that lb/mmbtu emission rates reported by the ERT are correct (i.e., that the calculation of emission rate from mass and gas volume corresponds to the lb/mmbtu value calculated in the stack test report). Various mistakes have been noted in the lb/mmbtu calculations, including the use of the wrong F-factor (i.e., wrong O 2 basis) and incorrect entry of process paramete rs. OTM: older versions of spreadsheet do not If possible, use the latest version of the Emissions (OTM) spreadsheet posted on EPA s ICR support additional test runs website. Do not insert columns, as this will cause problems for EPA s data extraction procedures. OTM: incorrect detection limit format In the OTM spreadsheet, values below detection limits should be entered in the Calculated Emission Rate field in brackets using the format [<##]. OTM: contents of Data Flag field differ from The Data Flag field (found in the May 18, 2010 and later versions of the EPA spreadsheet) should EPA requirements contain one of the following for every emission value: ADL, BDL, or DLL. In earlier versions, there is no Data Flag column and this information will have to be entered into the Other Supporting Information column. Check that all detection flags are assigned correctly. DLL indicates a multi- limit and the other fraction is below fraction method in which one fraction is above the detection detection limit. No other text should go in the Data Flag field! Results for the individual fractions should be entered in the Other Supporting Information field. ERT: EPA s Electronic Reporting Tool Table Version: August 17, 2010 Other important reporting issues: One issue that we have noted in most ICR data sets is the omission of the detection limit methodology requested by EPA for this ICR. Because laboratories are not consistent in how they derive detection or reporting limits, and EPA may use the reported nondetect values to determine regulatory limits, it is very important for the appropriate use of the ICR data that this information be provided. EPA has not provided guidance on the level of detail required. EPRI recommends including a concise statement of the basis of the values used to represent nondetects in the Comments field of the Electronic Reporting Tool and in the Other Supporting Information column of the OTM spreadsheet. A more detailed explanation of the methodology can be included in the Test Report.

3 Checklist of s: Method 26 or 26A Acid Gases (HCl and HF) Sodium hydroxide impinger used to If HCl and HF were measured using sodium hydroxide (NaOH)impingers, a note should be added to the measure acid gases ERT Comment field that this methodology was used. EPA initially recommended measuring acid gases and cyanide (HCN) in a combined Method 26/CTM-033 train using only NaOH impingers. This methodology generally resulted in HCl and HF detection limits about 100 times higher than the typical detection limit for Method 26, which uses sulfuric acid impingers for HCl and HF. EPA now recommends using a sulfuric acid impinger to measure acid gases. Quality control samples fail method Verify for all HCl and HF: laboratory control sample (LCS) spike recoveries between %, matrix spike/matrix spike duplicate recoveries between %, duplicate analyses of samples should agree within 5%. Results outside these ranges indicate uncertainty in the results due to inaccuracy or impreciseness and this should be noted in the ERT comments field. Incorrect probe/filter temperature for The Method 26 probe and filter should be heated above 248 F. Temperatures significantly lower than Method F can potentially lead to moisture condensation and a low bias in the sample results. Method 26 requires temperature to be above 248 F, not within the 248±25 F range specified by Method 5. Several sites have incorrectly performed Method 26 by adhering to the latter criterion. Chec klist of s: CTM-033 Hydrogen Cyanide (HCN) Sodium hydroxide impinger ph <12 Quality control (QC) samples fail method Verify that the final ph of the sodium hydroxide (NaOH) impinger liquid as received by the laboratory was >12. Low ph can result in low capture efficiency (i.e., a low bias in measured value). Note ph<12 in the Other Test Methods (OTM) Other Supporting Information column Verify: laboratory control sample (LCS) spike recoveries between %; matrix spike/matrix spike duplicate recovery between %; duplicate analyses of samples relative percent difference (RPD) <25%. Failure to meet these indicates greater uncertainty and potential bias in the results. QC values not meeting should be noted in the OTM Other Supporting Information column.

4 Checklist of s: Method 29/5 Metals and Particulate Matter (PM) Blank contamination for metals Calculate the ratio of the sample mass to the blank mass for each metal. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was very low. In either case, a note should be included in the ERT Comments field indicating that the reported mass may not be accurate due to the sample value being close to the blank value. Front half and back half metals results not EPA is requiring both components of the analysis (filter and impinger catch) to be reported in the ERT reported Comments field. For example: 5.8, [<0.5]. If the lab did not report front/back half results, note this in the Comments field. Incorrect summation of front/back half Sum fractions using the detection limit to represent masses below detection limit. Do not use zero to results represent nondetects. Blank correction performed incorrectly EPA states that blank correction should be performed per Method 29. When blank correction results in a value below the limit of detection, the detection limit should be used as the concentration value in summing the front half and back half fractions. Elevated manganese Highly elevated Mn has been observed when a permanganate impinger was included i n the sampling train. Back half sample Mn >50% of the front half Mn indicates likely contamination. In this case, a note regarding sample contamination should be made in the Comments field of the ERT. Quality control samples fail method Verify for all metals: laboratory control sample (LCS) spike recoveries between %, matrix spike/matrix spike duplicate recoveries between %. Recoveries outside of these ranges indicate a potential bias and this should be noted in the ERT Comments field. Method 5 PM results not reported Filterable PM results from the Method 5 filter associated with the Method 29 trains should be reported in the ERT. EPA does not require the PM results to be reported if a Method 5/OTM-28 train was run simultaneously with the Method 29 train. Incorrect filter temperature for Method The Method 5 filter associated with the Method 29 train should be heated at 248±25 F, not 320±25 F. 5/29 filter Several sites with wet stacks have mistakenly operated the filter at 320 F; for wet stacks; it is the Method 5 filter associated with OTM-28 that is held at 320 F. ERT: EPA s Electronic Reporting Tool

5 Checklist of s: Method 30B Mercury (Hg) Emissions calculated incorrectly Quality control (QC) samples fail method Incorrect sample mass entry for values below detection limit The Hg concentration reported for each run should be the average of the paired tubes (i.e., the average of the unspiked tube and the corrected value from the spiked tube). The Hg concentration for the tube should include the mass of Hg collected on the first bed and the second bed. For a Method 30B run to be valid, it must pass all three of the following QC : (1) Average of the first bed spike recovery for the three runs must be %. (2) Breakthrough to the second bed must be <10% (or <20% if concentration is <1 µg/m 3 ). (3) The paired trap agreement must be within 10% relative difference (RD), or 20% RD if concentration measured is < 1 µg/m 3. If a run is invalid, note this in the Other Supporting Information column of the Other Test Methods (OTM) spreadsheet. Verify that the sample mass falls within the calibration curve. Method 30B indicates that the lowest point of the calibration curve must be at least 5 times the Method Detection Limit and that all analyses of field samples must fall within the calibration curve. For very low mass emitters, it may be difficult to collect enough Hg on the first bed to exceed the lowest point on the calibration curve. Likewise, for samples with very low breakthrough to the second bed, the sample mass for the second bed may not exceed the lowest point on the calibration curve. In such cases, follow the specific instructions given in Section 11.3 of Method 30B for when the sample mass falls between the method detection limit (MDL) and the lowest point on the calibration curve.

6 Checklist of s: Method 5 at 320 F/OTM-28 Filterable and Condensable Particulate Matter (CPM) Incorrect filter temperature used Failure to report all PM fractions requested by EPA Blank correction performed incorrectly Blank contamination ERT: EPA s Electronic Reporting Tool EPA required that units with a wet stack perform Method 5 at a temperature of 320±25 F. This method should have been performed in conjunction with OTM-28. Running the method with the normal filter temperature of 248±25 F may produce a high bias in filterable PM and a low bias in CPM. EPA requested that the following four Particulate Matter (PM) results be reported in the ERT: 1. Filterable Particulate (from Method 5 train) 2. Organic Condensable Particulate (organic fraction of OTM-028) 3. Inorganic (Aqueous) Condensable Particulate (inorganic fraction of OTM-028) 4. Total Particulate (sum of the following fractions of the Method 5/OTM-028 train): a. Filterable Particulate b. Organic Condensable PM c. Inorganic Condensable PM OTM-28 requires that blank correction should be limited to g for the sum of the organic and inorganic CPM fractions. If the sum of the blank fractions exceeds g, the most accurate method of blank-correction is to allocate the g in proportion to the relative blank masses of the two fractions. However, this approach is not contained in OTM-28, which only addresses correction of the total CPM. Evaluate the ratio of the sample mass to the blank mass. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was very low. In either case, a note should be included in the ERT Comments field indicating that the reported mass may not be accurate due to the sample value being close to the blank value.

7 Checklist of s: OTM-27/OTM-28 PM2.5/Condensable Particulate Matter (CPM) Incorrect PM method used EPA required that units with a dry stack perform OTM-27 in conjunction with OTM-28. Failure to report all PM fractions requested EPA requested that the following six Particulate Matter (PM) numbers be reported in the Electronic by EPA Reporting Tool (ERT): 1. Filterable PM2.5 (Filterable PM < 2.5 from OTM-27) 2. Organic Condensable Particulate (organic fraction of OTM-028) 3. Inorganic (Aqueous) Condensable Particulate (inorganic fraction of OTM-028) 4. Total PM2.5 (sum of filterable PM < 2.5, Organic Condensable Particulate, Inorganic Condensable Particulate) 5. Filterable Particulate (sum of PM<2.5 and PM>2.5) 6. Total Particulate (sum of the following fractions of the OTM-027/028 train): a. Filterable PM > 2.5 b. Filterable PM < 2.5 c. Organic Condensable PM d. Inorganic Condensable PM Blank correction performed incorrectly OTM-28 requires that blank correction should be limited to g for the sum of the organic and inorganic CPM fractions. If the sum of the blank fractions exceeds g, the most accurate method of blank-correction is to allocate the g in proportion to the relative blank masses of the two fractions. However, this approach is not contained in OTM-28, which only addresses correction of the total CPM. Blank contamination The ratio of the sample mass to the blank mass should be evaluated. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was very low. ERT: EPA s Electronic Reporting Tool. In either case, a note should be included in the ERT Comments field indicating that the reported mass may not be accurate due to the sample value being close to the blank value.

8 Checklist of s: Method 23 Dioxins/Furans and PCBs Blank contamination The ratio of the sample mass to the blank mass should be evaluated for each compound. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was very low. In either case, a note should be included in the ERT Comments field indicating that the reported mass may not be accurate due to the sample value being close to the blank value. Incorrect reporting of non-detect values Do not use zero to represent nondetected congeners. Use the Estimated Detection Limit (EDL) for the specific sample and congener, as reported by the laboratory. Quality control indicators fail method Verify for all dioxin/furan congeners: internal standard/surrogate recoveries between % for tetra through hexa-cdds and -CDFs, and between % for hepta and octa -CDDs and -CDFs. Verify for all PCB congeners: internal standard recoveries and lab control sample (LCS) spike recoveries meet the laboratory s stated acceptance. Recoveries outside these ranges indicate higher uncertainty in the results and the out-of-range QC results should be noted in the ERT Comments field. Other dioxin/furan parameters not reported or reported incorrectly EMPC values not correctly coded ERT: EPA s Electronic Reporting Tool. EPA requires Other dioxin/furan congener groups (e.g., Other hexa-cdd) to be reported in the ERT, but Total dioxin/furan congener groups do not need to be reported. The calculation of the Other category is typically performed by subtracting the individual target congener results from the Total categories normally reported by laboratories. EPA has not provided guidance on how to handle values below detection limits in this computation. Do not report zeros for the Other dioxin/furan congener groups. Some laboratories assign an EMPC (Estimated Maximum Potential Concentration) flag to dioxin/furan results that do not meet all of the Method 23 for positive identification as a target compound. EPA has provided guidance that EMPC values should be indicated as follows: omit any entry into the Flag field of the ERT and enter EMPC in the Comments field. Note that some laboratories may use other symbols to indicate EMPC, but the same guidance would apply.

9 Checklist of s: Method 0010 Semivolatile Organic Compounds (SVOC) Blank contamination Evaluate the ratio of the sample mass to the blank mass for each compound. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was very low. In either case, note in the ERT Comments field that the reported mass may not be accurate due to the sample value being close to the blank value. Incorrect list of SVOC compounds Refer to EPA FAQ Questions Test-014 and Test-041 for guidance on which SVOC compounds to report. reported Please be aware that the laboratory may have reported compounds that are not Haza rdous Air Pollutants (HAPs). Incorrect summation of fractions for multi- The reported mass should be the sum of the individual fractions of the train. For fractions with results fraction methods below detection limit, the detection limit should be used in the summation and the DLL flag used in the Flag field. In no case should a zero value be used for a fraction.

10 Blank contamination Checklist of s: Method 0031 VOCs Evaluate the ratio of the sample mass to the blank mass for each compound. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was very low. In either case, a note should be included in the Other Test Methods (OTM) Other Supporting Information column indicating that the reported emissions may not be accurate due to the sample value being close to the blank value. It is very important to review the blank data for detected VOCs and to add a note to the Other Test Methods (OTM) Other Supporting Information field if the results are suspected to be due to contamination. Common laboratory solvents that are frequently seen as contaminants in Method 0031 include methylene chloride, acetone, and toluene. Low level detections are often due to the presence of these solvents in the sample recovery or laboratory areas. In some cases, gross contamination has been noted in ICR samples. Incorrect reporting of VOC compounds Incorrect summation of fractions for multifraction methods Benzene, chloromethane, and bromomethane are commonly detected as artifacts in Method 0031 samples and may not be derived from the emissions source. If these chemicals were detected, the possibility of sample field contamination should be investigated. A positive field blank result is evidence of contamination. However, since many contractors do not uncap the field blank tubes while in the field, a negative result in the field blanks does not rule out cross-contamination from solvents used in the field. Refer to EPA FAQ Questions Test-014 and Test-041 for guidance on which VOC compounds to report. Please be aware that the laboratory may have reported compounds that are not Hazardous Air Pollutants (HAPs). The reported mass should be the sum of the individual fractions of the train. For fractions with results below detection limit, the detection limit should be used in the summation and the DLL flag used in the Flag field. In no case should a zero value be used for a fraction.

11 Incorrect reporting of results Checklist of s: Method 18 Methane (CH 4 ) If Method 18 was performed with the direct interface method, EPA requires the concentrations to be reported as measured in the Emissions field, including negative values. All runs should be flagged as ADL in the Other Test Methods (OTM) spreadsheet Data Flag column. If Method 18 was performed as a bag sample and the results were below detection limit, then the detection limit should be reported in the OTM spreadsheet as [<XX] in the Emissions field, and a BDL flag should be entered in the Data Flag column. Quality control samples fail method If Method 18 was performed with the direct interface method, the system span recovery should be between %. If Method 18 was performed as a bag sample, then the bag recovery should be between %. Results that meet the recovery should still be corrected fo r the recovery. Recoveries outside these ranges indicate a likely bias in the results and should be noted in the OTM Other Supporting Information column. Background ( zero gas ) levels equivalent Evaluate the ratio of the sample concentration to the zero gas concentration for each run. A ratio of less to measured levels than approximately five indicates that either the zero gas or sampling system contained significant contamination or the sample mass was very low. In either case, a note should be included in OTM Other Supporting Information column indicating that the reported mass may not be accurate due to the sample value being close to the zero gas value. Checklist of s: Method 25A Total Hydrocarbons (THC) Incorrect reporting of results Method 25A is a direct interface method. EPA requires the concentrations to be reported as measured, including negative values. All runs should be flagged as ADL in the ERT Flag field. Background ( zero gas ) levels equivalent to measured levels ERT: EPA s Electronic Reporting Tool. Evaluate the ratio of the sample concentration to the zero gas concentration for each run. A ratio of less than approximately five indicates that either the zero gas or sampling system contained significant contamination or the sample mass was very low. In either case, a note should be included in the ERT Comments field indicating that the reported mass may not be accurate due to the sample value being close to the zero gas value.

12 Checklist of s: Method 0011 Formaldehyde Blank contamination Quality control samples fail method Evaluate the ratio of the sample mass to the blank mass. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was very low. In either case, a note should be included in the Other Test Methods (OTM) Other Supporting Information column indicating that the reported emissions may not be accurate due to the sampl e value being close to the blank value. Verify that lab control sample (LCS) spike recoveries meet the laboratory s stated acceptance. Checklist of s: Method 316 Formaldehyde Blank contamination Quality control samples fail method Evaluate the ratio of the sample mass to the blank mass. A ratio of less than approximately five indicates that either the blank contained significant contamination or the sample mass was ve ry low. In either case, a note should be included in the Other Test Methods (OTM) Other Supporting Information column indicating that the reported emissions may not be accurate due to the sample value being close to the blank value. Verify that lab control sample (LCS) spike recoveries meet the laboratory s stated acceptance.

Data Quality Issue No. 1: Incorrect Filter Temperature for Filterable Particulate Tests

Data Quality Issue No. 1: Incorrect Filter Temperature for Filterable Particulate Tests October 27, 2010 Mr. William Maxwell U.S. Environmental Protection Agency Subject: Evaluation of Data Quality Issues for the EGU ICR Part III Data Dear Mr. Maxwell: Since May 2010, EPRI has been engaged

More information

EPRI Hazardous Air Pollutants Information Collection Request Data Review Summary

EPRI Hazardous Air Pollutants Information Collection Request Data Review Summary EPRI Hazardous Air Pollutants Information Collection Request Data Review Summary June 30, 2010 (revised July 1) Paul Chu, Naomi Goodman, Babu Nott, Chuck Dene, George Offen, Christina Kemp Webcast Presenters

More information

PM 2.5 and CPM Emission Measurements Understanding the Limitations and Implications

PM 2.5 and CPM Emission Measurements Understanding the Limitations and Implications PM 2.5 and CPM Emission Measurements Understanding the Limitations and Implications Vipin Varma and Ashok Jain NCASI AWMA Louisiana Section A Multi-Media Forum October 30, 2013 Outline PM 2.5 Definitions

More information

Project Summary Products of Incomplete Combustion from Direct Burning Of Pentachlorophenol-treated Wood Wastes

Project Summary Products of Incomplete Combustion from Direct Burning Of Pentachlorophenol-treated Wood Wastes United States Environmental Protection National Risk Management Research Laboratory Agency Research Triangle Park, NC 27711 Research and Development EPA/600/SR-98/013 Project Summary Products of Incomplete

More information

A G. The Avogadro Group, LLC. Air Quality Consulting and Source Emissions Testing

A G. The Avogadro Group, LLC. Air Quality Consulting and Source Emissions Testing A G The Avogadro Group, LLC Air Quality Consulting and Source Emissions Testing ALL THESE TEST RESULTS ARE THE SAME POLLUTANT FROM THE SAME BOILER!! Different test methods CAN = different results! Recent

More information

Serving the Power Industry

Serving the Power Industry 1 14 C COMPOUNDS OF INTEREST Organic Carbon Gases primary form for PWRs 14 CH 4 and other hydrocarbons Inorganic Carbon Gases primary form for BWRs 14 CO 2, 14 CO not formed in appreciable quantities Particulate

More information

Metro Vancouver Metrotower III 4730 Kingsway Burnaby, BC V5H 0C6

Metro Vancouver Metrotower III 4730 Kingsway Burnaby, BC V5H 0C6 METRO VANCOUVER WASTE-TO-ENERGY FACILITY COMPLIANCE TESTING REPORT November 2017 Emission Survey Prepared For: Metro Vancouver Metrotower III 4730 Kingsway Burnaby, BC V5H 0C6 Prepared by: A. Lanfranco

More information

Project Summary. Field Evaluation of EPA Method 0040 (Volatiles Using Bags)

Project Summary. Field Evaluation of EPA Method 0040 (Volatiles Using Bags) United States National Exposure Environmental Protection Research Laboratory Agency Research Triangle Park NC 27711 Research and Development EPA/600/SR-98/030 May 1998 Project Summary Field Evaluation

More information

FINAL REPORT: June 30, Advanced Technology Systems, Inc. 639 Alpha Drive Pittsburgh, PA 15238

FINAL REPORT: June 30, Advanced Technology Systems, Inc. 639 Alpha Drive Pittsburgh, PA 15238 FINAL REPORT: DEVELOPMENT OF ANALYTICAL METHODS FOR THE QUANTIFICATION OF THE CHEMICAL FORMS OF MERCURY AND OTHER TARGET POLLUTANTS IN COAL- FIRED BOILER FLUE GAS DOE Contract No. DE-AC22-92PC92583--01

More information

Can your unit pass a Particulate Emission Compliance Test?

Can your unit pass a Particulate Emission Compliance Test? Source Emissions Testing and Emissions Specialists Can your unit pass a Particulate Emission Compliance Test? Kevin Crosby The Avogadro Group, LLC California - Oregon - Arizona McIlvaine Hot Topic Hour,

More information

Continuous Emissions Monitoring in Support of the Cement MACT

Continuous Emissions Monitoring in Support of the Cement MACT Continuous Emissions Monitoring in Support of the Cement MACT McIlvaine Webinar on Cement MACT March 30, 2011 Topics Covered Overview of Portland Cement MACT Mercury monitoring on cement kilns PM CEMS

More information

Florida Department of Environmental Protection. Field and Lab Audits

Florida Department of Environmental Protection. Field and Lab Audits Florida Department of Environmental Protection Field and Lab Audits What is an Audit? Check that data and processes are of sufficient quality for environmental decision-making Data Quality Objectives (DQOs)

More information

Joette L. Steger, Joan T. Bursey, and David Epperson

Joette L. Steger, Joan T. Bursey, and David Epperson United States National Exposure Environmental Protection Research Laboratory Agency Research Triangle Park, NC 27711 Research and Development EPA/600/SR-97/140 April 1998 Project Summary Acetonitrile Field

More information

Your Technology Resource

Your Technology Resource Volume 2, No. 2 Your Technology Resource Analytical Techniques for MACT Industrial Boilers Emissions Standards by Dr. David Edelman, Practical Analytical Solutions On September 13, 2004, the EPA promulgated

More information

PM 10 /PM 2.5 Test Method

PM 10 /PM 2.5 Test Method PM 10 /PM 2.5 Test Method MARAMA Webinar 10/20/2011 Ron Myers EPA/OAQPS myers.ron@epa.gov Presentation Topics Condensable PM test method Particle sizing test method Timeline Implications of new test methods

More information

The following table summarizes the average test results for the three tests conducted by ORTECH and the corresponding emission criteria:

The following table summarizes the average test results for the three tests conducted by ORTECH and the corresponding emission criteria: EXECUTIVE SUMMARY ORTECH Environmental (ORTECH) was requested by Clean Harbors to conduct a comprehensive emission testing program at the incineration facility located at 4090 Telfer Road in Corunna, Ontario.

More information

Gap Filling HAPs. For Point Sources in the 2008 National Emissions Inventory

Gap Filling HAPs. For Point Sources in the 2008 National Emissions Inventory Gap Filling HAPs and other HAP additions by EPA For Point Sources in the 2008 National Emissions Inventory 1 Pollutants Included in the NEI Criteria Pollutants/Precursors (CAPs) Required To Be Reported

More information

Environmental Performance Test of Hazardous Waste Incinerator in Indonesia

Environmental Performance Test of Hazardous Waste Incinerator in Indonesia Environmental Performance Test of Hazardous Waste Incinerator in Indonesia Prof. Kardono, Ph.D. Environmental Technology Center Agency for the Assessment and Application of Technology (BPPT) Jakarta, INDONESIA

More information

A Summary of the Changes in the Newly Promulgated GC/MS Method for Volatile Organics in Wastewater

A Summary of the Changes in the Newly Promulgated GC/MS Method for Volatile Organics in Wastewater EPA Method 624.1 A Summary of the Changes in the Newly Promulgated GC/MS Method for Volatile Organics in Wastewater Harry McCarty and Kevin Roberts CSRA, Alexandria, VA The best laid schemes o' Mice an'

More information

APPENDIX B SOURCE TEST METHODS

APPENDIX B SOURCE TEST METHODS SOURCE TEST METHODS This appendix provides information on source test methods for the Canada, the United States, and Mexico. Source test methods used nationally by Canada are presented in Table B.1, and

More information

GENERAL TESTING AND REPORTING REQUIREMENTS

GENERAL TESTING AND REPORTING REQUIREMENTS GENERAL TESTING AND REPORTING REQUIREMENTS Ohio EPA requires that an Ohio Intent to Test ( ITT ) form be filed with the appropriate Ohio EPA representative at least 30 days (or more if required by regulation)

More information

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR White paper WP/ANALYTICAL/002 EN ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field

More information

Method 0040 for Volatile Total Organics as Unspeciated Mass in Stack Gas Emissions

Method 0040 for Volatile Total Organics as Unspeciated Mass in Stack Gas Emissions Method 0040 for Volatile Total Organics as Unspeciated Mass in Stack Gas Emissions Sampling and Field Procedure for Volatile Unspeciated Mass from Method 0040 Samples in Stack Gas Sample Name: Sampler:

More information

Data Validation Report

Data Validation Report AECOM 978-95-21 tel 25 Apollo Drive 978-95-211 fa Chelmsford, MA 1824 Data Validation Report Project: Laboratory: PPG Dennis Collins Park (1 st Street Park) TestAmerica Laboratories, Inc., Edison, NJ Laboratory

More information

STEPS TO DMR-QA SUCCESS. BY: Marcy Bolek

STEPS TO DMR-QA SUCCESS. BY: Marcy Bolek STEPS TO DMR-QA SUCCESS BY: Marcy Bolek marcy@alloway.com Presentation Overview Purpose of DMR-QA Preparation DMR-QA Ethics Analysis Ammonia BOD Residual Chlorine ph TSS Quality Control Reporting What

More information

Measurement of Hydrogen Cyanide Air Emissions in Refinery Operations

Measurement of Hydrogen Cyanide Air Emissions in Refinery Operations Measurement of Hydrogen Cyanide Air Emissions in Refinery Operations www.trcsolutions.com November 10, 2016 oduction 2011 ICR for Refinery Sector requested HCN emissionss from FCCU Requested Method was

More information

Ensuring Data Integrity

Ensuring Data Integrity Ensuring Data Integrity Gina Plantz Severn Trent Laboratories, Inc. gplantz@stl-inc.com NEWMOA Vapor Intrusion Seminar Chelmsford, MA April 12 th, 2006 Focus Areas Measurement of VOCs & non-vocs Soil Gas,

More information

METHOD 30B DETERMINATION OF TOTAL VAPOR PHASE MERCURY EMISSIONS FROM COAL-FIRED COMBUSTION SOURCES USING CARBON SORBENT TRAPS

METHOD 30B DETERMINATION OF TOTAL VAPOR PHASE MERCURY EMISSIONS FROM COAL-FIRED COMBUSTION SOURCES USING CARBON SORBENT TRAPS METHOD 30B DETERMINATION OF TOTAL VAPOR PHASE MERCURY EMISSIONS FROM COAL-FIRED COMBUSTION SOURCES USING CARBON SORBENT TRAPS Disclaimer: EPA is considering taking direct final action later this year to

More information

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER

INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER 1 INDUSTRIAL MEASUREMENTS USING FTIR GAS ANALYZER Brief introduction, thoughts and experiences MOTIVATION FOR EMISSION MEASUREMENTS 2 Condition of environment Air quality Emission studies Dispersion models

More information

Method Determination of Condensible Particulate Emissions from Stationary Sources

Method Determination of Condensible Particulate Emissions from Stationary Sources EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER TEST METHOD Method 0 - Determination of Condensible Particulate Emissions from Stationary Sources 1. APPLICABILITY AND PRINCIPLE 1.1 Applicability. 1.1.1

More information

Greenhouse Gas Regulation (new Federal)

Greenhouse Gas Regulation (new Federal) Mercury & Air Toxics (MATS) Interstate Transport (CAIR/CSAPR) Regional Haze/Visibility Portland Cement NESHAP Greenhouse Gas Regulation (new Federal) Mercury & Air Toxics (MATS) Finalized December 2011

More information

Page 1 of 26 Revision October 2001

Page 1 of 26 Revision October 2001 Page 1 of 26 Table of Contents Section Page No I. PURPOSE AND SCOPE... 3 II. AUTHORITY... 3 III. REFERENCE... 3 IV. RESPONSIBILITY... 3 V. POLICY... 3 VI. PROCEDURE... 4 A. Introduction... 4 B. Data Validation

More information

Available Laboratory Methods for Soil Gas Analysis

Available Laboratory Methods for Soil Gas Analysis Available Laboratory Methods for Soil Gas Analysis US EPA Soil Gas Sample Collection & Analysis Workshop San Diego, CA March 21-22, 2007 Gina M. Plantz NewFields Environmental Forensics Practice, LLC gplantz@newfields.com

More information

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015 John Downs Environmental Manager, B&W PGG, KVB-Enertec Products January 29, 2015 Introduction What is a CEMS? Regulatory Drivers for CEMS Quality Assurance of CEMS Summary & Question A continuous emission

More information

PREPARATION AND REVIEW OF EMISSION TEST REPORTS. U. S. EPA Contract No. 68-D EMB Work Assignment No Prepared by:

PREPARATION AND REVIEW OF EMISSION TEST REPORTS. U. S. EPA Contract No. 68-D EMB Work Assignment No Prepared by: GUIDEBOOK PREPARATION AND REVIEW OF EMISSION TEST REPORTS U. S. EPA Contract No. 68-D9-0055 EMB Work Assignment No. 2-98 Prepared by: Entropy Environmentalists, Inc. Research Triangle Park, North Carolina

More information

SERVICE PROVIDERS AND SERVICE CONTRACTS

SERVICE PROVIDERS AND SERVICE CONTRACTS SERVICE PROVIDERS AND SERVICE CONTRACTS Table of Contents Service Provider and Service Contract Records... 3 Property Service Provider Records... 4 Contacts... 7 Service Providers...11 Service Contracts...13

More information

Compliance of Biomass Plants with PM2.5 and MACT Emission Limits: The Risks of Emission Testing

Compliance of Biomass Plants with PM2.5 and MACT Emission Limits: The Risks of Emission Testing Source Emissions Testing and Emissions Specialists Compliance of Biomass Plants with PM2.5 and MACT Emission Limits: The Risks of Emission Testing Craig Thiry Business Development Director Kevin Crosby

More information

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS MS 1596: 2003 DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS Presented BY: UiTM A&A Laboratory Malaysia s 1 st University Affiliated Environmental

More information

EPA vs. EN standards

EPA vs. EN standards EPA vs. EN standards 1 Tasks Goal: Determination of differences and similarities of EN and EPA to get a guideline what to change to be consistent within the EN CEMS framework Text comparison Approx. 1

More information

Mercury Sampling: A Comparison of Common Test Methods

Mercury Sampling: A Comparison of Common Test Methods Mercury Sampling: A Comparison of Common Test Methods Tina Sanderson, B.Sc. QSTI Senior Specialist Emission Testing ORTECH Consulting Inc. AWMA Ontario Section Air and Acoustic Monitoring Conference October

More information

Investigation Requirements for Ethanol-Blended Fuel Releases Petroleum Remediation Program

Investigation Requirements for Ethanol-Blended Fuel Releases Petroleum Remediation Program Investigation Requirements for Ethanol-Blended Fuel Releases Petroleum Remediation Program Guidance Document 4-21 This guidance document describes site investigation requirements for ethanol-blended fuel

More information

New Developments in Thermal Desorption (TD) Tube & Canister Technologies for Collection & Analysis of Soil Gas

New Developments in Thermal Desorption (TD) Tube & Canister Technologies for Collection & Analysis of Soil Gas New Developments in Thermal Desorption (TD) Tube & Canister Technologies for Collection & Analysis of Soil Gas Presented by Roy Smith, M.Sc., MBA, C.Chem. Why Use TD Tube or Canister Sampling For Collection

More information

Case Study: Pulse Jet Fabric Filter & Dry Sorbent Injection for Biomass Boiler Application

Case Study: Pulse Jet Fabric Filter & Dry Sorbent Injection for Biomass Boiler Application Case Study: Pulse Jet Fabric Filter & Dry Sorbent Injection for Biomass Boiler Application Jeffrey D. Shellenberger, 1 James B. Gilmour, 1 Aku Rainio 2 ; 1 Foster Wheeler North America Corp., Pittsburgh,

More information

EPRI COMMENTS ON PROPOSED HAPS MACT RULE

EPRI COMMENTS ON PROPOSED HAPS MACT RULE EPRI COMMENTS ON PROPOSED HAPS MACT RULE U.S. Environmental Protection Agency National Emissions Standards for Hazardous Air Pollutants from Coal and Oil- Fired Electric Utility Steam Generating Units

More information

Data Usability Summary PCB Rinse Water May/June 2011

Data Usability Summary PCB Rinse Water May/June 2011 Texas Custodial Trust 2301 West Paisano Drive El Paso, Texas 79922-1622 Data Usability Summary PCB Rinse Water May/June 2011 July 2011 6835001 Report Prepared By: Malcolm Pirnie, Inc. 211 North Florence

More information

Compliance Measurements. Mike Klein & Robert Kettig BTS (609)

Compliance Measurements. Mike Klein & Robert Kettig BTS (609) Compliance Measurements Mike Klein & Robert Kettig BTS (609) 530-4140 BTS Emission Measurement Section Bureau Chief (vacant) 1 Section Chief 1 Supervisor 5* Staff Professionals + 1-2 part time Consultants

More information

BACKGROUND DOCUMENT PROPOSED REVISION TO AP-42 EMISSION FACTORS FOR ESTIMATING PM 2.5 EMISSIONS FROM GAS-FIRED COMBUSTION UNITS

BACKGROUND DOCUMENT PROPOSED REVISION TO AP-42 EMISSION FACTORS FOR ESTIMATING PM 2.5 EMISSIONS FROM GAS-FIRED COMBUSTION UNITS BACKGROUND DOCUMENT PROPOSED REVISION TO AP-42 EMISSION FACTORS FOR ESTIMATING PM 2.5 EMISSIONS FROM GAS-FIRED COMBUSTION UNITS Submitted by: Karin Ritter American Petroleum Institute 1220 L Street NW

More information

Monitoring cement plant stack emissions using FTIR

Monitoring cement plant stack emissions using FTIR ABB MEASUREMENT & ANALYTICS WHITE PAPER Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field study Measurement

More information

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities CEM 2014 May 15-17, 2014 Istanbul, Turkey Peter G. Zemek MultiGas FT-IR Automated HCl CEM Systems MKS Instruments On-Line Product

More information

Sampling and Sample Integrity

Sampling and Sample Integrity Sampling and Sample Integrity Hazel Davidson Technical Marketing Manager Sampling and Sample Integrity BS 10175: 2011 Deviating samples Containers/Preservatives/Filtration Temperature/Transportation Storage/Holding

More information

SLEIS Walkthrough Guide. Jacquelyn Cuneo DNREC Division of Air Quality (302)

SLEIS Walkthrough Guide. Jacquelyn Cuneo DNREC Division of Air Quality (302) SLEIS Walkthrough Guide Jacquelyn Cuneo DNREC Division of Air Quality jacquelyn.cuneo@state.de.us (302) 739-9402 1 SLEIS Home Page Web address: http://apps.dnrec.state.de.us/sleis/ Welcome Application

More information

Regulation 85. Navigating Regulation 85 Part II Lab Methods and Data Submission

Regulation 85. Navigating Regulation 85 Part II Lab Methods and Data Submission Regulation 85 Navigating Regulation 85 Part II Lab Methods and Data Submission Presented By: Colorado Water Quality Monitoring Council (CWQMC) and Colorado Monitoring Framework (CMF) rk (CMF) Presenters

More information

FLEX FUEL GASIFIER SIMULATION MODEL (v1.0) USER MANUAL

FLEX FUEL GASIFIER SIMULATION MODEL (v1.0) USER MANUAL FLEX FUEL GASIFIER SIMULATION MODEL (v1.0) USER MANUAL Developed By: Gas Processing Research Laboratory Department of Chemical and Biological Engineering Illinois Institute of Technology Chicago, IL. P

More information

Allegheny County Health Department. Air Toxics Study

Allegheny County Health Department. Air Toxics Study Allegheny County Health Department Air Toxics Study Air Toxic Study Goals Measure selected air toxics in local communities Develop a cancer and non-cancer cumulative risk analysis Source apportionment

More information

Direct PM Emissions 2.5 Data, Testing, and Monitoring Issues

Direct PM Emissions 2.5 Data, Testing, and Monitoring Issues Direct PM Emissions 2.5 Data, Testing, and Monitoring Issues Ron Myers myers.ron@epa.gov Measurement Policy Group SPPD, OAQPS The Issues Collecting data needed for effective inventories and SIP development

More information

Online Gas Analyzer / Monitor

Online Gas Analyzer / Monitor Sheet No. 1 of 9 CH4 H2 SOX NOX NH3 CO2 HF HCL HCN CO O2 Providing the latest in Combustion Gas & Emission Analyzers for Boiler, Engine, Furnace, and other applications. Sheet No. 2 of 9 Vasthi OMGA 8000

More information

Transcript. The Toolkit Level 2 Spreadsheet

Transcript. The Toolkit Level 2 Spreadsheet Transcript The Toolkit Level 2 Spreadsheet Mercury:Learn Inventory Level 2 Modules Now we will look in detail at the Toolkit s spreadsheet and how its different elements work. What is described in this

More information

WM 03 Conference, February 23-27, 2003, Tucson, AZ IN-SITU CHEMICAL OXIDATION OF CHLORINATED HYDROCARBONS IN THE PRESENCE OF RADIONUCLIDES

WM 03 Conference, February 23-27, 2003, Tucson, AZ IN-SITU CHEMICAL OXIDATION OF CHLORINATED HYDROCARBONS IN THE PRESENCE OF RADIONUCLIDES IN-SITU CHEMICAL OXIDATION OF CHLORINATED HYDROCARBONS IN THE PRESENCE OF RADIONUCLIDES ABSTRACT Duane K. Root, Shaw Environmental & Infrastructure Treatability testing for In Situ Chemical Oxidation was

More information

CT DEP Reasonable Confidence Protocols. Glen Breland, VP Member CT DEP QA/QC Workgroup

CT DEP Reasonable Confidence Protocols. Glen Breland, VP Member CT DEP QA/QC Workgroup CT DEP Reasonable Confidence Protocols Glen Breland, VP Member CT DEP QA/QC Workgroup Reasonable Confidence Protocols (RCPs) Overview Why develop the RCPs? What are the RCPs? What is Reasonable Confidence?

More information

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide 3M Personal Safety Division 3M TM EVM Series Environmental Monitor EVM Series Quick Start Guide EVM and User Interface Indicators Display Softkey menus Backlight Particulate pump Left arrow key Run/Stop

More information

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide 3M Personal Safety Division 3M TM EVM Series Environmental Monitor EVM Series Quick Start Guide EVM and User Interface Indicators Display Softkey menus Backlight Particulate pump Left arrow key Run/Stop

More information

Parsons. APPENDIX E Laboratory Data Validation Reports Calscience Environmental Laboratories, Inc.

Parsons. APPENDIX E Laboratory Data Validation Reports Calscience Environmental Laboratories, Inc. Parsons APPENDIX E Laboratory Data Validation Reports Calscience Environmental Laboratories, Inc. Laboratory Data Validation Report Sixteen groundwater samples (including fourteen primary and two field

More information

Investigating the Extraction Efficiency of Dioxins in Several Types of Aqueous Matrices by Automated Solid Phase Extraction Utilizing Disks

Investigating the Extraction Efficiency of Dioxins in Several Types of Aqueous Matrices by Automated Solid Phase Extraction Utilizing Disks Investigating the Extraction Efficiency of Dioxins in Several Types of Aqueous Matrices by Automated Solid Phase Extraction Utilizing Disks James Fenster and Michael Ebitson, Horizon Technology, Inc.,

More information

QUICK START GUIDE. EVM Series Environmental Monitor

QUICK START GUIDE. EVM Series Environmental Monitor QUICK START GUIDE EVM Series Environmental Monitor EVM and User Interface Indicators Display Backlight Particulate Pump Left Arrow Key Softkey Menus Up Arrow Key Altf Key Enter Key Right Arrow Key Down

More information

Study of Air Toxics Released from the Pre- Harvest Burning of Sugarcane

Study of Air Toxics Released from the Pre- Harvest Burning of Sugarcane A&WMA International Specialty Conference Leapfrogging Opportunities for Air Quality Improvement Study of Air Toxics Released from the Pre- Harvest Burning of Sugarcane Danielle Hall, Jun Wang, Kuei-Min

More information

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis

Sampling and Analysis in Vapor Intrusion Investigations. Andy Rezendes, Technical Sales-Air Analysis Sampling and Analysis in Vapor Intrusion Investigations Andy Rezendes, Technical Sales-Air Analysis Introduction General Principles Introduction to Measurement Techniques for VOCs in Air Principles of

More information

Representing the Interests of America s Industrial Energy Users since May 20, 2011

Representing the Interests of America s Industrial Energy Users since May 20, 2011 Representing the Interests of America s Industrial Energy Users since 1978 May 20, 2011 The Honorable Lisa P. Jackson, Administrator U.S. Environmental Protection Agency Ariel Rios Building 1200 Pennsylvania

More information

Stack Testing Oversight in New Jersey

Stack Testing Oversight in New Jersey Stack Testing Oversight in New Jersey Michael Klein - Section Chief Emission Measurement Section ACE Academy May 4, 2016 Emission Measurement Section (EMS) The Emission Measurement Section is responsible

More information

Maxxam Contracted by CCME Jan 2012

Maxxam Contracted by CCME Jan 2012 CCME Volume IV Guidance Manual for Environmental Site Characterization in Support of Environmental and Human Health Risk Assessment Volume IV Analytical Methods Prepared by Barry Loescher PhD PChem September

More information

Guest Speaker: Bill Frietsche US EPA

Guest Speaker: Bill Frietsche US EPA Guest Speaker: Bill Frietsche US EPA 1 April 7: QA Systems, EPA definitions, PQAOs and common sense Mike Papp April 14: Routine Quality Control and Data Management (1-pt QC, flow rate, and instrument stability

More information

Direct Deposit. In order to use direct deposit, you must set special parameters in the general ledger, deductions, and miscellaneous parameters.

Direct Deposit. In order to use direct deposit, you must set special parameters in the general ledger, deductions, and miscellaneous parameters. Setting up Direct Deposit Direct Deposit In order to use direct deposit, you must set special parameters in the general ledger, deductions, and miscellaneous parameters. General Ledger In the Setup for

More information

Dan Deatsch Thompson Environmental Consulting

Dan Deatsch Thompson Environmental Consulting Dan Deatsch Thompson Environmental Consulting Three methods for testing particulate matter emissions Method 5 and d17 Particulate t Matter Emissions i Method 201A PM10 and PM2.5 Emissions Method 202 Condensable

More information

November Prepared By: :

November Prepared By: : U.S. EPA Region 2 Brownfields Planning Document for Site-Specific Quality Assurance Region 2 Brownfields Quality Assurance Program Prepared By: : U.S. EPA Region 2 Brownfields Quality Assurance Office

More information

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the 312 METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g., sampling) essential

More information

Field-tests at Kiviõli Keemiatööstus OÜ oil-shale processing plant in Kiviõli, Estonia

Field-tests at Kiviõli Keemiatööstus OÜ oil-shale processing plant in Kiviõli, Estonia Field-tests at Kiviõli Keemiatööstus OÜ oil-shale processing plant in Kiviõli, Estonia Introduction The field-tests for plasma-treatment of exhaust gases were carried out in several different sites of

More information

Volatile Organic Compounds in Solids PBM

Volatile Organic Compounds in Solids PBM Organics Revision Date: Aug 15, 2014 Volatile Organic Compounds in Solids PBM Parameter Analytical Method Introduction Method Summary Parameter Applicability, MDLs Volatile Organic Compounds (VOCs) in

More information

NOTIFICATION OF COMPLIANCE (NOC) WITH THE REQUIREMENTS OF 40 CFR 63 SUBPART EEE FOR THE FIXED BOX INCINERATOR #2

NOTIFICATION OF COMPLIANCE (NOC) WITH THE REQUIREMENTS OF 40 CFR 63 SUBPART EEE FOR THE FIXED BOX INCINERATOR #2 NOTIFICATION OF COMPLIANCE (NOC) WITH THE REQUIREMENTS OF 40 CFR 63 SUBPART EEE FOR THE FIXED BOX INCINERATOR #2 Prepared for: 260 Hudson River Road Waterford, New York 12188 Prepared by: Franklin Engineering

More information

Attachment 2. Quality Assurance and Operating Procedures for Sorbent Trap Monitoring Systems

Attachment 2. Quality Assurance and Operating Procedures for Sorbent Trap Monitoring Systems Attachment 2 Quality Assurance and Operating Procedures for Sorbent Trap Monitoring Systems 1.0 Scope and Application This Attachment specifies sampling, analytical, and quality-assurance criteria and

More information

2TouchPOS DataKey Module

2TouchPOS DataKey Module 2TouchPOS DataKey Module 2013 2TouchPOS 82 Saint Paul Street Rochester, NY 14604 Phone 585.325.5242 Fax 585.325.6989 Contents About this Document... 3 What is DataKey?... 4 Philosophies and Definitions...

More information

DR1000 Flying Laboratory, Drone Environmental Monitoring

DR1000 Flying Laboratory, Drone Environmental Monitoring cccc DR1000 Flying Laboratory, Drone Environmental Monitoring 1 P a g e Mission Statement The Scentroid DR1000 is a fully capable flying laboratory, used to sample and analyze ambient air at heights of

More information

APPENDIX A TECHNICAL SUPPLEMENTS

APPENDIX A TECHNICAL SUPPLEMENTS APPENDIX A TECHNICAL SUPPLEMENTS Disclaimer The Emissions Assessment Section (EAS) has developed technical supplements for several common emission sources. The supplements are intended to help you accurately

More information

BSK Labs Frequently Asked Questions

BSK Labs Frequently Asked Questions BSK Labs Frequently Asked Questions 1. How long has BSK Laboratories been in business? BSK Analytical Laboratories began operations in 1967, as a division of BSK Associates, a civil engineering firm founded

More information

Data Pack. Methods for the Determination of Cyanide Using Amperometric Detection. June 2008

Data Pack. Methods for the Determination of Cyanide Using Amperometric Detection. June 2008 Data Pack Methods for the Determination of Cyanide Using Amperometric Detection June 2008 This Data Pack contains support data and apparatus information on three Lachat methods for the determination of

More information

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems

A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems A global monitoring systems offering. A world of advantages. Thermo Scientific Continuous Emissions Monitoring Systems Part of Thermo Fisher Scientific The complete solution Clean Air commitment. Since

More information

Presentation Overview Air Quality Regulations Evolution in the U.S. Summary of Current NESHAPS Regulations Mercury Emissions Control and Measurement T

Presentation Overview Air Quality Regulations Evolution in the U.S. Summary of Current NESHAPS Regulations Mercury Emissions Control and Measurement T A Review of the Evolution, Status and Compliance Initiatives Associated with Process Mercury Emissions Monitoring Standards in the United States CEM 2014 International Conference and Exhibition On Emissions

More information

Air Pollution Technology Fact Sheet

Air Pollution Technology Fact Sheet Air Pollution Technology Fact Sheet 1. Name of Technology: Packed-Bed/Packed-Tower Wet Scrubber This type of technology is a part of the group of air pollution controls collectively referred to as wet

More information

NPOC, VOC, TC-IC and TDN using Shimadzu TOC-V Protocols. Water Quality Analysis Laboratory at the University of New Hampshire

NPOC, VOC, TC-IC and TDN using Shimadzu TOC-V Protocols. Water Quality Analysis Laboratory at the University of New Hampshire NPOC, VOC, TC-IC and TDN using Shimadzu TOC-V Protocols Water Quality Analysis Laboratory at the University of New Hampshire Prepared by: Jeffrey Merriam Date of Last Revision: 10/26/2004 Signature of

More information

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry Introduction New environmental regulations have recently prompted many oil refineries and

More information

D.9 Particulate Nitrogen and Particulate Carbon

D.9 Particulate Nitrogen and Particulate Carbon D.9 Particulate Nitrogen and Particulate Carbon CEDR Method Codes: PN L01 PC L01 1.1 Scope and Application 1.1.1 Elemental analysis is used to determine total particulate carbon (PC) and total particulate

More information

Nonylphenols and Ethoxylates in Water by LC/MS/MS

Nonylphenols and Ethoxylates in Water by LC/MS/MS Nonylphenols and Ethoxylates in Water by LC/MS/MS Organics Revision Date: Sept 15, 2017 Parameter MDLs and EMS Analyte Codes Analytical method Introduction Method summary Nonylphenol and Nonylphenol Ethoxylates

More information

Measurement uncertainty implications for the enforcement of emission limits. Maciek Lewandowski (Environment Agency)& Michael Woodfield (AEAT) UK

Measurement uncertainty implications for the enforcement of emission limits. Maciek Lewandowski (Environment Agency)& Michael Woodfield (AEAT) UK Measurement uncertainty implications for the enforcement of emission limits Maciek Lewandowski (Environment Agency)& Michael Woodfield (AEAT) UK INTRODUCTION The second generation EC Directives such as

More information

Volatile Organic Carbon Contaminated Site Assessment

Volatile Organic Carbon Contaminated Site Assessment 92 Volatile Organic Carbon Contaminated Site Assessment Introduction Roughly 75 percent of the major cities in the U.S. depend, at least in part, on groundwater for their water supply. Various estimates

More information

Perform Time Employer Features

Perform Time Employer Features Perform Time Employer Features Welcome to Perform Time! Paycor has built Perform Time with your needs in mind. It s improved usability and expanded features set will make your job easier. Here s just a

More information

Ask The Expert Webinar Series Vapor Intrusion Assessments Part Two: Improving Data Quality Using Today s Best Practices for Sample Analysis

Ask The Expert Webinar Series Vapor Intrusion Assessments Part Two: Improving Data Quality Using Today s Best Practices for Sample Analysis Ask The Expert Webinar Series Vapor Intrusion Assessments Part Two: Improving Data Quality Using Today s Best Practices for Sample Analysis Taryn McKnight Client Relations Manager The migration of volatile

More information

Electronic Data Validation Using the Locus Environmental Information Management System. Tricia Walters Locus Technologies

Electronic Data Validation Using the Locus Environmental Information Management System. Tricia Walters Locus Technologies Electronic Data Validation Using the Locus Environmental Information Management System Tricia Walters Locus Technologies Locus Technologies 2014 Agenda Introduction Environmental Information Management

More information

Question Your Data. Jim Hays EXPERIMENT:

Question Your Data. Jim Hays EXPERIMENT: Question Your Data EXPERIMENT: A SCIENTIFIC PROCEDURE UNDERTAKEN TO MAKE A DISCOVERY, TEST A HYPOTHESIS OR DEMONSTRATE A KNOWN FACT. Jim Hays JHays@encolabs.com 2 Laboratory Certification 3 HTTP://NELAC-

More information

Eagle Business Management System - Manufacturing

Eagle Business Management System - Manufacturing Eagle Business Management System - Manufacturing Table of Contents INTRODUCTION...1 Technical Support...1 Overview...2 CREATING A BATCH...5 Creating a Simple Manufacturing Batch...5 Using Inventory Components

More information

MITIGATION MDNITDRING PROGRAM (Accompanies the Van Nuys Fire Station 39 Environmental Impact Report SCH No ) Van Nuys Fire Station 39

MITIGATION MDNITDRING PROGRAM (Accompanies the Van Nuys Fire Station 39 Environmental Impact Report SCH No ) Van Nuys Fire Station 39 MITIGATION MDNITDRING PROGRAM (Accompanies the Van Nuys Fire Station 39 Environmental Impact Report SCH No. 2015031067) Van Nuys Fire Station 39 W.O. E170094B ENGINEERING mtm CITY OF LOS ANGELES Transmittal

More information

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while Sorbents Evaluation Testing Facilities Several states have enacted Hg emission regulations that are more stringent than the CAMR milestones. For example, Massachusetts will require power plants to achieve

More information

SUGGESTIONS FOR REDUCTION OF ANALYTICAL COSTS BY ELIMINATION OF UNNECESSARY QUALITY CONTROL (QC) SAMPLES

SUGGESTIONS FOR REDUCTION OF ANALYTICAL COSTS BY ELIMINATION OF UNNECESSARY QUALITY CONTROL (QC) SAMPLES SUGGESTIONS FOR REDUCTION OF ANALYTICAL COSTS BY ELIMINATION OF UNNECESSARY QUALITY CONTROL (QC) SAMPLES Douglas M. Chatham 5413 Forest Ridge Dr., Loganville, GA 30052-3437 Environmental Specialist and

More information