WELLMATE COMPOSITE PRESSURE TANKS WATER PURIFICATION TANKS & SYSTEMS - WELLMATE
|
|
- Florence Johnson
- 6 years ago
- Views:
Transcription
1 WELLMATE COMPOSITE TANKS WATER PURIFICATION TANKS & SYSTEMS - WELLMATE
2 RESIDENTIAL COMMERCIAL AGRICULTURAL For well systems, water storage, and pressure boosting. PENTAIR WELLMATE OFFERS DEALERS MORE ADVANTAGES, MORE SOLUTIONS FOR MORE. A GROWING CUSTOMER BASE. In the residential, commercial, and agricultural markets of the world, Pentair Wellmate composite tanks have long been the tank of choice for their unmatched performance over steel. As the recognized leader in composite pressure tank design, Pentair Wellmate Water Systems give you more to sell. With unique features that translate into real benefits for your customers, Wellmate by Pentair sets you apart from the competition. A MATERIAL DIFFERENCE. From the high-density polyethylene inner liner, to the fiberglass-wound and epoxy resin-sealed outer shell, Pentair Wellmate tanks do not contain steel, so they will not rust. What they can do is make everything easier. Wellmate Tanks by Pentair require little or no maintenance because they won t dent and they do not have paint to scratch and touch up. Their light weight half that of steel tanks makes them easier and faster to install. In fact, most can be handled by a single installer, keeping costs down. Pentair Wellmate Tanks are certified to CE and NSF/ANSI std. section 8 and Annex G and are 00% lead-free. In addition, they will not introduce undesirable chemicals or elements into the water. A PRODUCT THAT S WORTH MORE. Innovative Pentair Wellmate solutions for water storage and pressure boosting applications offer you a world class product that s worth more. From initial design through promised delivery, quality is a hallmark of Wellmate by Pentair Tanks. State-of-the-art equipment, the best materials and an ISO-900 certified manufacturing facility guarantee that our one-piece composite construction is second to none. ONGOING DEALER SUPPORT. As a Pentair Wellmate dealer, you ll enjoy total dealer support. Wellmate Tanks by Pentair are only sold through a network of select professional dealers, giving you a real opportunity to make your mark. In addition, Pentair Wellmate dealers enjoy the benefits of sales training programs, seminars and technical support, as well as marketing support and dealer incentive programs. Want to know more about Wellmate by Pentair and the edge it gives its dealers? Call your Pentair Wellmate distributor or visit com for more information. TABLE OF CONTENTS - LOW-PROFILE SERIES - WM -SERIES 7-8 UT -SERIES 9-0 HP-SERIES - E-SERIES UNIVERSAL/HP AERATION TANKS RESIDENTIAL TANK REPLACEMENT GUIDE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE
3 LP-SERIES (STANDARD ) CLASSIC LOW-PROFILE CAPTIVE AIR TANKS BIG ON PERFORMANCE, SMALL ON SPACE. PEU AIR CELL Designed for height-restricted applications such as mobile homes, crawl spaces and closets, our compact LP-Series pressure tanks give you added flexibility in smallspace residential applications. Plus they offer you these distinct advantages: Air Cell, easier to service in the field. Lightweight easier to maneuver. Mobile Homes Crawl Spaces Closets Available in CLASSIC drain assembly, polyether urethane (PEU) air cell. Highest Drawdown in the Industry for its Profile. HERE ARE THE FEATURES THAT SET US APART Durable, polyether urethane (PEU) air cell is fully replaceable. One-piece seamless inner shell is molded of high-density polyethylene. Outer shell is composed of continuous fiberglass strands sealed with high-grade epoxy resin. Sturdy, molded polymeric base is corrosion and impact proof. Bottom inlet/outlet assembly is custom molded of highimpact PVC. SPECIFICATIONS CLASSIC DRAWDOWN 0/0 SETTING** GAL/LITER SYSTEM CONNECTION WM-LP / WM-LP / 7 / 8 / 8..8 /.9 / 0. /. /.7 " male NPT.7 / 0. WM-0LP / WM-LP-0. / / 8 / / 9. / 8 / 7. /.7 " male NPT 9. /. NOTE: Maximum external operating temperature 0 F (9 C). Maximum internal operating temperature 00 F (8 C). Minimum operating temperature 0 F ( C). * Diameter, height and weight may vary slightly without notice. ** In keeping with current industry standards, drawdown factors are based on Boyle s law. Actual drawdowns will vary depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system. WATER PURIFICATION TANKS & SYSTEMS - WELLMATE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE
4 CLASSIC WM-SERIES (CLASSIC ) CAPTIVE AIR TANKS HERE ARE THE FEATURES THAT SET US APART Durable, polyether urethane (PEU) air cell is fully replaceable. EASY TO INSTALL, MAINTAIN, AND SERVICE. Our WM-Series offers features and benefits that steel tanks just can t match. From their corrosion-proof composite construction to their lighter weight, easier maintenance and less expensive installation,wm-series pressure tanks are the preferred choice of professionals, especially when the following advantages are added to the mix: Available in CLASSIC drain assembly, polyetherurethane (PEU) air cell. Residential Light Commercial Pressure Boosting One-piece seamless inner shell is molded of highdensity polyethylene. Outer shell is composed of continuous fiberglass strands sealed with highgrade epoxy resin. Sturdy, molded polymeric base is corrosion- and impact-proof. Bottom inlet/outlet onepiece drain is custom molded of high-impact PVC. PEU AIR CELL Replaceable Air Cell for easier field servicing. Easy to carry. Easy and Less Costly to Install usually requiring only one person and fewer man-hours. Greater Drawdown than Comparably-Sized Steel Tanks for greater efficiency. Won t Rust in Corrosive Environments particularly important in agricultural and livestock applications, and coastal regions. CPVC Drain Assembly (threaded) SPECIFICATIONS CLASSIC DRAWDOWN 0/0 SETTING** GAL/LITER SYSTEM CONNECTION WM- / WM000. / / 8 / 8.. /. / /.7 /. " male NPT. /. WM- / WM / 7 / 8 / 8..9 /. / / 8.7 /. " male NPT 7.7 / 8. WM-9 / WM00 9. / / 8 / /. / /.7/. " male NPT.7 /. WM-WB / WM / 78 / 8 / 8.. /. /. / 0. /.7 /" male NPT / 9. WM-0WB / WM0 0.0 / 7 / 8 / / 8. /. / 0. /.7 /" male NPT 0 /.7 WM- / WM / 0 / 8 / 8..8 / 90. / / 7. /.7 /" male NPT.7 / 9.8 WM-WB / WM / 8 / 8 / 8..0 / 98. /. / 0. /.7 /" male NPT 7.7 /.0 WM-WB / WM / / 8 / 8..9 /.9 / 7. / 89. /.7 /" male NPT 9 /. NOTE: Maximum external operating temperature 0 F (9 C). Maximum internal operating temperature 00 F (8 C). Minimum operating temperature 0 F ( C). * Diameter, height and weight may vary slightly without notice. ** In keeping with current industry standards, drawdown factors are based on Boyle s law. Actual drawdowns will vary depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system. WATER PURIFICATION TANKS & SYSTEMS - WELLMATE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE
5 UT-SERIES HERE ARE THE FEATURES THAT SET US APART UNIVERSAL RETENTION TANKS Vacuum breaker required. Standard " ID / " Quick Connect Socket. DO YOU HAVE CONTACT WITH CHEMICALS, CHLORINE, HYDROGEN SULFIDE? GO WITH THE PROS AND CHOOSE UT. There s no better tank choice for water treatment than our UT-Quick Connect Series. Composite construction makes the entire line impervious to the chemicals found in aggressive water. Plus the following advantages give our UT-Quick Connect Series the kind of application versatility dealers want: Inlet/Outlet PVC Pipe Connections allow straight through T connection on bottom of tank for ease of piping. Blowdown Valve for easy removal of sludge from bottom of tank. Hydropneumatic Convertible optional air volume control assembly and micronizer allow for quick and easy tank conversion. Dealers no longer need to stock more than one kind of air-overwater pressure tank. Contact Tank for Water Treatment Hydropneumatic (with purchased accessories) One piece, seamless inner shell molded of premium, high-density polyethylene which provides impact and corrosion resistance. Miles of fiberglass filament covered with epoxy resin produce superior strength in a light-weight design. Additional drain port. Curved bottom dome design maximizes contact time and facilitates sludge removal. " socket inlet/outlet PVC pipe connections offer maximum application flexibility. CHEMICAL TANK PUMP WATER IN TO BLOWDOWN VALVE SPECIFICATIONS QUICK CONNECT SYSTEM CONNECTION TOP BOTTOM UT-0 / WM-UT-0 / CE 0 / 7 / 00 /.0 /. /. /.8 /" Socket Q.C. /" Socket /. UT-0 / WM-UT-0 / CE 0 / 7 / 00 /.0 / 7. /. /.8 /" Socket Q.C. /" Socket 8 /.7 UT-0SQ / WM-UT-0-SQ / CE 0 / 7 / 00 /.0 / / 9 /. /" Socket Q.C. /" Socket /.0 UT-80 / WM-UT-00 / CE 80 / 0 7 / 00 /.0 /.7 / 9 /. /" Socket Q.C. /" Socket / 9. UT-0 / WM-UT-0 / CE 0 / 7 / 00 /.0 / 7. / 8 /. /" Socket Q.C. /" Socket / 8. NOTE: Maximum external operating temperature 0 F (9 C). Maximum internal operating temperature 00 F (8 C). Minimum operating temperature 0 F ( C). *Diameter, height and weight may vary slightly without notice. ACCESSORIES (For Hydropneumatic Conversion) (Consult factory for correct size) Air Volume Control Assembly Part #CH99- Part #CH9 Vacuum Breaker /" NPT Air Volume Control Assembly Vacuum Breaker NOTE: Flexible connectors must be installed between hard piping and tank openings. These pressure vessels are rated for an internal negative pressure of " HG (7 Pa) vacuum below atmospheric.if negative pressure could ever exceed " Hg (7 Pa), an adequate vacuum breaker must also be properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty. 7 WATER PURIFICATION TANKS & SYSTEMS - WELLMATE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE 8
6 HP-SERIES HERE ARE THE FEATURES THAT SET US APART HYDRO-PNEUMATIC AIR/WATER TANKS THE TOUGHEST TANKS FOR YOUR MOST DIFFICULT INSTALLS. Iron and sulfur removal? Methane and other undesirable well gases? You need our HP-Quick Connect Series of hydropneumatic tanks. These high performance tanks can be used for aggressive water, or as an open system where air is introduced to oxidize and aerate. All this, plus these other key advantages: Large Drawdown Ratio for increased efficiency. Adapter and UT Drain Assembly (sold separately) allows you to add " riser pipe to increase aeration of water. See page. Self-Adjusting Air Volume Control for system flexibility and ease of installation. Sulfer and Iron Water Treatment Hypochloride Environments Release of Methane or Other Well Gases " vent line. 0 rotating threadless connection. Top-mounted air volume control provides 0% or more drawdown than similar sized conventional tanks. Miles of fiberglass filament covered with epoxy resin produce superior strength in a light-weight design. Self-adjusting air volume control a Pentair Wellmate exclusive. One piece, seamless inner shell molded of premium, high-density polyethylene which provides impact and corrosion resistance. Convex bottom design with top-mounted air volume control maximizes drawdown. 7 " socket inlet/outlet PVC pipe connections offer maximum application flexibility. 8 Blowdown port with " NPT connection. MICRONIZER INLET 8 7 TO SERVICE SPECIFICATIONS QUICK CONNECT DRAWDOWN 0/0 SETTING** GAL/LITER SYSTEM CONNECTION TOP BOTTOM HP-7/WM-HP-0 0 / 7 / 00 /.0. /.0 /.7 /. /.8 /" vent line /" Socket /.8 HP-9/WM-HP-0 0 / 7 / 00 / /. /. /. /.8 /" vent line /" Socket 9 /. HP-8SQ/WM-HP-0SQ 0 / 7 / 00 / / 0. /. / 90 /. /" vent line /" Socket /. HP-8/WM-HP / 0 7 / 00 / / 7. / / 7 /. /" vent line /" Socket / 0.0 HP-/WM-HP-0 0 / 7 / 00 /.0. / 9. / 7. / 8 /. /" vent line /" Socket / 9.0 NOTE: Maximum external operating temperature 0oF (9oC). Maximum internal operating temperature 00oF (8oC). Minimum operating temperature 0oF (oc). * Diameter, height and weight may vary slightly without notice. ** In keeping with current industry standards, drawdown factors are based on Boyle s law. Actual drawdowns will vary depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system. ACCESSORIES Part #CH99- Part #CH9 Vacuum Breaker /" NPT Vacuum Breaker NOTE: Flexible connectors must be installed between hard piping and tank openings. These pressure vessels are rated for an internal negative pressure of " HG (7 Pa) vacuum below atmospheric.if negative pressure could ever exceed " Hg (7 Pa), an adequate vacuum breaker must also be properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty. 9 WATER PURIFICATION TANKS & SYSTEMS - WELLMATE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE 0
7 E-SERIES CAPTIVE AIR AND RETENTION TANKS STORAGE. MINIMUM HEADACHES. Wider pressure switch settings on our E-Series tanks allow for maximum water storage during periods of peak demand. As a captive air tank, the E-Series can handle up to psi/8. bar operating pressure. Plus the highvolume, high-pressure tanks offer these benefits: Retention Tank Capability without the air cell, can function as a high capacity retention tank for water storage and treatment. Polyether Urethane (PEU) Air Cell offers a longer life than bladders or diaphragms. Wider Range of Pressure Settings for greater application versatility. Pre-Installed Inlet/Outlet Assembly with system connections to save time and money. High Volume Water Storage Water Storage Treatment HERE ARE THE FEATURES THAT SET US APART Air cell polyether urethane (PEU) captive air tank only. Vessel fiberglass and epoxy filament wound onto a onepiece molded liner. Base glass filled sheet molding compound. CAPTIVE AIR TANK RETENTION TANK Our E-Series tanks are also available as a retention tank for water storage/treatment. SPECIFICATIONS DRAWDOWN 0/0 SETTING** GAL/LITER SYSTEM CONNECTION TOP BOTTOM CAPTIVE AIR TANK WM-0 87 / 707 / 8 / 8.. /09 0 / 7 79 / 0 7. / 9 N/A " FNPT / 0. WM-80 / 999 / 8 / / 9 / 9 8 / / 0 N/A " FNPT 9 /. RETENTION TANK RT / 707 / 8 / 8. N/A 0 / 7 79 / 0 7. / 9 " NPSM " MNPT / 0. RT-70 / 999 / 8 / 8. N/A / 9 8 / / 0 " NPSM " MNPT 9 /. NOTE: Maximum external operating temperature 0 F (9 C). Maximum internal operating temperature 00 F (8 C). Minimum operating temperature 0 F ( C). * Diameter, height and weight may vary slightly without notice. ** In keeping with current industry standards, drawdown factors are based on Boyle s law. Actual drawdowns will vary depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system. WATER PURIFICATION TANKS & SYSTEMS - WELLMATE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE
8 UT/HP AERATION TANKS /" vent line. 0 rotating threadless connection. Vacuum breaker required.* (Refer to note below) RESIDENTIAL TANK REPLACEMENT GUIDE HOW TO AIR OUT UNDESIRABLE GASES. Got a problem with undesirable well gases? These tanks have been designed to introduce air to oxidize and aerate, minimizing or even eliminating both methane gas and hydrogen sulfide gas which is detectable by its rotten egg odor. These tough-performing tanks also offer the following: Large Drawdown Ratio for increased efficiency. Self Adjusting Air Volume Control System for flexibility and ease of installation. Water level. Cap and pipe with /" drilled holes to distribute flow (minimum -7 holes required). Riser tube of " pipe (customer supplied). Adapter P/N CH08. Vacuum breaker required for HP applications. 7 Air volume control system Adjustment knob 8 Air Inlet Indicator INLET TO SERVICE PENTAIR WELLMATE WM-0 WM-0 WM-/ WM000 QC WM-LP/ WM-LP-07 QC WM-/ WM007 QC WM-9/ WM00 QC WM-0LP/ WM-LP-0 QC WM-/ WM00 QC WM- WM00 QC WM-WB WM080 QC WM-0WB WM0 QC WM- WM000 QC WM-WB WM00 QC Gallons Champion Amtrol ProLine Amtrol Well-Flow Amtrol WellXTrol Amtrol Clayton Mark WM-WB WM00 QC CH00 CH00 CH00 n/a CH0 CH80 n/a n/a CH80 CH000 CH0 n/a CH7 CH00 CA00 CA00 CA00 n/a CA0 CA80 n/a n/a CA000 CA000 CA0 n/a CA700 CA00 WF- WF- WF- n/a WF0 WF00 n/a n/a n/a WF0 WF00 n/a WF0 WF0 WX-0 WX-0 WX-0 n/a WX-0 WX-0 n/a n/a WX-0 WX-0 WX- n/a WX- WX-0 CM00 CM00 CM-00 n/a CM-0 CM-0 n/a n/a n/a CM-0 CM- n/a CM-0 CM-0 Elbl D8 D8 DV0 n/a DV80 n/a n/a n/a n/a DV00 n/a n/a n/a DV0 Challenger Flexcon JR JR PC n/a PC PC n/a n/a PC PC PC n/a PC PC Composite Construction for increased tank life. WARNING: To avoid health or environmental hazards from gas accumulation, plumb the top fitting to vent off gas to a safe area. Well-Rite Flexcon JR JR WR n/a WR0 WR80 n/a n/a WR0 WR0 WR00 n/a WR0 WR0 *Pentair Wellmate does not guarantee sizing requirements or the successful removal of odors and gases. It is the responsibility of the contractor or water treatment specialist to assess the many variables involved and select the proper tank. Flex-Lite n/a n/a FL- n/a FL-7 n/a n/a n/a FL- FL-7 FL- FL-8 FL-0 FL-0 Aqua Air Goulds V8P VP V n/a V0 V00 n/a n/a n/a V0 V00 n/a V0 V0 Myers MIL MIL MPD n/a MPD0 n/a n/a n/a n/a n/a n/a n/a MPD8 MPD9 ConAire Sta-Rite CA-9 n/a n/a n/a CA- n/a n/a n/a n/a CA-0 n/a n/a CA-0 n/a Pro Source Fiberwound n/a n/a PSC-- n/a PSC-0- PSC-0-9 n/a PSC--0 PSC-0- PSC-8- PSC-0-0 PSC-80- PSC-8- PSC-9- SPECIFICATIONS ACCESSORIES Vertical Steel Sta-Rite SR n/a n/a PS0-T0 n/a PSPT-T0 PSP7T-T0 n/a n/a n/a PSP0-T0 PSP00-T n/a PSP0-T PSP0-TR0 QUICK CONNECT " RISER TUBE LENGTH (INCHES) / AVC (TUBE ONLY) (INCHES) AVC LENGTH (INCHES) UT-0 / HP-7 0 / Part # CH99- Part # CH9 Part # CH08 Vacuum Breaker /" NPT Adapter Vertical Steel ProSource Vertical Steel ProSource PLUS PS-S0 PS-S0 PS-S0 n/a PS9S-T0 PS-T0 n/a n/a PS-T0 PS0-T0 PS-T n/a PS8-T PS9-TR0 n/a n/a n/a n/a PSP9T-0 PSP9S-T0 PSP-T0 n/a n/a PSP-T0 PSP0-T0 PSP-T n/a PSP8-T PSP9-TR0 UT-0SQ / HP-8SQ 0 / UT-0 / HP-9 0 / Perma Tank State PIL- PIL- PAD- n/a PAD-0 n/a n/a n/a n/a PAD- n/a n/a PAD-8 PAD-9 UT-80 / HP-8 80 / UT-0 / HP- 0 / Vacuum Breaker NOTE: Maximum external operating temperature 0 F (9 C). Maximum internal operating temperature 00 F (8 C). Minimum operating temperature 0 F ( C). Diameter, height and weight may vary slightly without notice. In keeping with current industry standards, drawdown factors are based on Boyle s law. Actual drawdowns will vary depending upon system variables, including the accuracy and operation of the pressure switch and gauge and operating temperature of the system. NOTE: Flexible connectors must be installed between hard piping and tank openings. These pressure vessels are rated for an internal negative pressure of " HG (7 Pa) vacuum below atmospheric. If negative pressure could ever exceed " Hg (7 Pa), an adequate vacuum breaker must also be properly installed. Failure to install flex connection properly, or improper installation of a vacuum breaker when required, may void the warranty. WATER PURIFICATION TANKS & SYSTEMS - WELLMATE WATER PURIFICATION TANKS & SYSTEMS - WELLMATE
9 TWO OF THE MOST COMMON HYDROPNEUMATIC Tank Sizing Information There are three factors to consider when selecting the proper size Pentair Wellmate for your water system: The pump delivery rate in gallons/liters per minute (GPM/LPM). The recommended minimum running time of the pump. The minimum (cut-in) and maximum (cut-out) system pressure parameters. Once these factors are known, the following calculations will determine, in most cases, the correct model to meet your specifications.* Shallow Well or Pressure Boosting System CALCULATING DRAWDOWN ) Pump delivery rate GPM/LPM ) Desired minimum pump running time in minutes Minutes ( minute, seconds =.7 minutes). ) Multiply line # by line #. Gallons/Liters This is the minimum drawdown or available water volume required.* CALCULATING TANK SIZE ) Minimum system pressure (cut-in) PSIG/kPa/bar ) Maximum system pressure (cut-out) PSIG/kPa/bar ) Using table #, find the drawdown Factor factor applicable to lines # and #. 7) Divide line # by line # to Gallons/Liters determine the minimum total Wellmate volume required. 8) Refer to the design data and select Model the Wellmate model with the lowest total capacity that is greater than or equal to line #7. Deep Well System EXAMPLE: An application using an 8 GPM pump with a minimum run time of minute and a 0-0 PSIG system pressure range; 8 GPM x minute.0 (factor) =.7 gallon minimum tank capacity *If a volume of water needed is greater than the amount calculated on line #, enter that amount on line # in place of the calculated volume. TABLE # DRAWDOWN FACTORS SYSTEM (CUT-OUT) PSIG/(kPa)/bar 0 (8).8 (7).7 0 (07).0 (). 0 (7).7 ().0 MINIMUM SYSTEM (CUT-IN) PSIG/(kPa)/bar 0 (). (80).80 0 (). (9).8 70 (8).8 7 (8).7 80 (). 8 (87).8 90 ().0 9 (). 00 (90).89 0 (7) 7. 0 (79) 7.8 0/(07)/.0 /()/. 0/(7)/.7 /()/.0 0/()/. /(80)/.80 0/()/. /(9)/.8 70/(8)/.8 7/(8)/.7 80/()/. 8/(87)/.8 90/()/.0 9/()/. 00/(90)/.89 0/(7)/7. 0/(79)/7.8 /(79)/7.9 0/(88)/8.7 /(8)/ In keeping with current industry standards, drawdown factors are based on Boyle s law. Actual drawdowns will vary depending upon system variables, including the accuracy and operation of the pressure switch and gauge, actual precharge pressure, and operating temperature of the system. WATER PURIFICATION 70 NORTH GLEN PARK ROAD, MILWAUKEE, WI , CUSTOMER CARE: , All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. WM08 DE 0 Pentair Residential Filtration, LLC. All Rights Reserved. MKT-BRO-0-EN-B
Featuring Antimicrobial Protection
Featuring Antimicrobial Protection Well Above The Rest Amtrol Inc. invented the first pre-pressurized well tank over 50 years ago. This revolutionary product featured an innovative design using a hoop
More informationFeaturing Antimicrobial Protection
Featuring Antimicrobial Protection Well Above The Rest Amtrol Inc. invented the first pre-pressurized well tank over 50 years ago. This revolutionary product featured an innovative design using a hoop
More informationWater Treatment. Water Conditioning Parts - Aquatrol Pressure Tanks
Water Treatment Pressure Tanks Aquatrol Pressure Tanks offer a reliable and cost-effective alternative for all of your light residential to heavy-duty commercial applications. Aquatrol tanks are available
More informationValve Nest Filter with Time Clock Control Installation and Operation Manual
Valve Nest Filter with Time Clock Control Installation and Operation Manual Effective 5/24/12 Effective 5/24/12 Table of Contents Operating Data. 1 Pre-Installation Data... 2 Filter Parameters Installation
More informationRead Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED
Chapter 17 Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.1.1 Applicability The regulations in this chapter apply to any private potable water supply system where plumbing fixtures are
More informationSECTION CHEMICAL FEED SYSTEM
SECTION 11800 PART 1 GENERAL 1.1 SUMMARY A. This section includes the requirements for the chemical feed system shall be a complete turnkey system inclusive of all necessary fluid handling and ancillary
More informationMax Head ' 1/ ' 115 1" FNPT 10' Manual On/Off Little Giant (5-MSPR) '
25/05/18 E56 Submersible Little-Giant 550486 & 505300: Utility pump where water must be transferred or recirculated, designed for continuous duty Pumps down to 1/8" Includes garden hose adapter & removable
More informationRolairtrol Air Separator For Hot and Chilled Water Systems
REMOVES ENTRAINED AIR To protect the system against damage To eliminate system noise TANGENTIAL FLOW PATTERN Increases air separation efficiency Allows use of smaller sizes than required with straight
More informationFLUIDPRO SERIES MEMBRANE AIR DRYERS WITH OPTIONAL PREFILTRATION AND OPTIONAL PURGE CONTROL ENGINEERED FILTRATION
FLUIDPRO SERIES MEMBRANE AIR DRYERS WITH OPTIONAL PREFILTRATION AND OPTIONAL PURGE CONTROL STATE-OF-THE-ART MEMBRANE TECHNOLOGY The FluidPro Membrane Air Dryer technology is proven to make it easier and
More informationEngineering Excellence
Energy Saving Compressed Air Filters NGF SERIES 20 to 1500 scfm (34 to 2459 nm 3 /h) Engineering Excellence SPX is a place where innovation is valued, and the real needs of business are understood. We
More informationNaturalSof WDR (Well Done Right) Installation and Troubleshooting Manual
NaturalSof WDR (Well Done Right) Installation and Troubleshooting Manual Contents Introduction... 3 Water Quality & Conditions... 3 Weather Considerations... 3 Professional Installers & Local Laws... 4
More informationINDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System
INDUSTRIAL SEPARATE BED DEIONIZER High Purity Industrial Packaged System (Twin System with carbon Filtration Tanks shown) 1 P age Deionization is the removal or reduction of positive ions called cations
More informationThe Culligan Hi-Flo 50 Series Industrial Water Filter System
The Culligan Hi-Flo 50 Series Industrial Water Filter System Durable High-Volume Water Filtration for Industrial Applications The Culligan Hi-Flo 50 Filter reduces contaminants* and solids that affect
More informationCulligan Medallist Series Whole House Water Filters
Culligan Medallist Series Whole House Water Filters Hey Culligan Man! Local Water Expertise Trusted Leader for 70 Years Certified Sales, Installation and Service Professionals 100% Satisfaction Guarantee**
More informationSUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH. Max. Flow 44. Max. Head 20. Voltage 115
SUMP / EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPSE3A 1/3 44 0 1½ NPT EFFLUENT PUMPS ARE SINGLE PHASE WITH PIGGYBACK FLOAT SWITCH PL-CPE4A-1 PL-CPE5A-1 PL-CPEH5A1 PL-CPSTEP51A PL-CPSTEP10A
More informationBONDSTRAND Glassfiber Reinforced Epoxy Piping Systems for Offshore Applications
BONDSTRAND Glassfiber Reinforced Epoxy Piping Systems for Offshore Applications Bondstrand Glassfiber Reinforced Epoxy Piping Systems Historically, offshore production platform, drilling rig and FPSO owners
More informationdiaphragm valves Diaphragm Valves
Diaphragm Valves Index Safety Warning Inside Front Cover 2-way Diaphragm Valves Pneumatic Actuated Valves 4 DV Series- How to Order Matrix 7 Disclaimers Inside Back Cover GO Regulator PO Box 4866 Spartanburg,
More informationINDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series
INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age filtration equipment can be engineered to solve complex commercial and industrial water treatment
More informationGrease Management. EnduraGreaseManagement.com. Rethinking Grease Interception
Grease Management EnduraGreaseManagement.com Rethinking Grease Interception Endura has the right stuff The Right Reason Guided by a philosophy of minimizing downstream toxic waste, Endura engineers have
More informationSkimmers. The Industry Standard for Performance and Reliability. For All Types of Inground and Aboveground Swimming Pools
Skimmers The Industry Standard for Performance and Reliability For All Types of Inground and Aboveground Swimming Pools Admiral S15 Admiral Skimmers Built tough for reliable service. Admiral skimmers offer
More informationBIO GT Series. Water Treatment Systems for Golf/Turf Maintenance Facilities
Water Treatment Systems for Golf/Turf Maintenance Facilities SCE Water Treatment Systems provide a better tomorrow by protecting our environment today. A Biological water treatment system can save thousands
More informationSAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)
SAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61) PART 1-GENERAL 1.01 Requirements 1. The CONTRACTOR shall provide SAFE-Tank
More informationPREMIER Low Profile Induced Draft Cooling Tower Specifications
Fa Delta Cooling Towers, Inc. 185 US Highway 206 Roxbury Township, NJ 07836 973.586.2201 973.586.2243 fax www.deltacooling.com sales@deltacooling.com PREMIER Low Profile Induced Draft Cooling Tower Specifications
More informationCOMMERCIAL WATER SOFTENER LWTF SERIES
COMMERCIAL WATER SOFTENER LWTF SERIES 30,000 TO 1,100,000 GRAINS CAPACITY WATER SOLUTIONS * COMMERCIAL GRADE PERFORMANCE * CONTINUOUS SOFT WATER * (Single, Twin, Triple or Quadruple systems) 1 P a g e
More informationA Green Solutions Company TM ENGINEERED PRODUCTS
A Green Solutions Company ENGINEERED PRODUCTS A Green Solutions Company Table of Contents The World Leader EZ-FLO Injection systems has proudly offered premium grade injectors, fertilizing products, and
More informationBuildingName The Description of the Project P DOCUMENTS
ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION
More informationYou get more for less at FSHS!
You get more for less at FSHS! www.puromax.com Phone (941)625 4550 Fax (941)625-6635 4210 Whidden Blvd. Port Charlotte, FL 33980 Phone (941)625-4550 Fax (941)625-6635 www.puromax.com Contacts President
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SCP Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationROTH MultiTank. Call or visit our web site at
ROTH MultiTank Call 866-943-7256 or visit our web site at www.roth-america.com R O T H Mu lt i Ta n k Setting the standards for all other tanks. The Roth MultiTank offers undisputed best-in-class status
More informationYORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE
YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE Contents YORK Passive Chilled Beams 3 CB-PBE-YK / CB-PBR-YK Performance Data 5 CB-PBE-YK Dimensions 7 CB-PBR-YK Dimensions 8 Specifications 9 2 YORK Passive
More informationSERIES AK 1400T SINGLE STAGE PRESSURE REGULATOR TIED DIAPHRAGM SAFETY AND RELIABILITY
SERIES AK 1400T SINGLE STAGE PRESSURE REGULATOR TIED DIAPHRAGM SAFETY AND RELIABILITY Flow capacity* 200 sccm to 500 slpm (0.007 to 17.6 scfm) Vacuum to 2,300 psig (158 bar) inlet, 100 psig (7 bar) outlet
More informationHigh Pressure Filter Assemblies
High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than
More informationOdor Control Products
Adsorbers Scrubbers Biofilters Accessories Chemical Storage Tanks www.endurocomposites.com Welcome to Enduro. This catalog provides an overview to Enduro s product lines for odor control. In the following
More informationBALL VALVES SUPERIOR BALL VALVES WA SERIES (WELDED) WA Series Ball Valve. WAS Series Ball Valve (With Access Fitting)
BALL VALVES SUPERIOR BALL VALVES WA SERIES (WELDED) WAS Series (Welded with Access Fittings) Full Refrigeration Service Temperature Range of -40 F to +325 F. Forged Brass Body and Seal Cap. Design Working
More informationSoftener and Filters Components and Accessories
SECTION 12 Softener and Filters Components and Accessories Section 12 Softener and Filter Components and Accessories Catalog 999502 Effective 01/01/13 Table of Contents SOFTENER COMPONENTS AND ACCESSORIES
More informationDETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS
5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS 1.0 SCOPE 1.1 Provide
More informationdiaphragm valves DV1 Series 2-Way Diaphragm Valves Typical Applications Analytical Instrumentation Petrochemical Pharmaceutical Chemical
DV1 Series 2-Way Diaphragm Valves The DV1 Series Diaphragm Valves are totally free of springs, bellows, packing, o-rings and lubricants in the process wetted area. Metal-to-metal seals to atmosphere ensure
More informationMASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version
MASTER Water Conditioning Corp. www.masterwater.com OPERATION MANUAL PURO PRO 1200 SC Series Modular Reverse Osmosis System January 2012 Version Table of Contents Model Number... 1 Shipping Description
More informationAkiki Engineering Est.
Akiki Engineering Est. Water & Steam Experts 1.1. Filtration Catalogue October 7, 2010 Contents Commercial Sand Filter................................. 3 Commercial Carbon Filter................................
More informationA. This section is intended to provide design guidelines for Utility Direct Buried Piping and Conduit Systems.
Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to provide design guidelines for Utility Direct Buried
More informationLine Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST
Line Filters 7-0 Solid, simple, smart. Advanced reliability in compressed air. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY PARTNERSHIP SERVICEABILITY
More information.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.
Construction of Sodium Hypochlorite and Chemical Storage Buildings Page 1 of 7 1. GENERAL 1.1 Scope.1 Boiler feed tank and pumps..2 Blowdown tanks..3 Water Softener System 1.2 Quality Assurance.1 All equipment,
More informationDELTA. Cooling Towers, Inc. Delta Cooling Towers. Leader in Non-Corrosive Cooling Tower Technology
DELTA Delta Cooling Towers Leader in Non-Corrosive Cooling Tower Technology PIONEER DELTA Forced Draft, Counter Flow Design 10-100 Ton Single Modules Pioneer cooling towers are forced draft counter flow
More informationContents. dimensions and weights external loads deflection and testing installation...17
GRAVITY SEWER Contents 01 02 03 04 05 06 07 08 09 product description...2 short form specification...5 dimensions and weights....................... 6 flow/discharge charts....................... 8 external
More informationTotal Operational Efficiency
Total Operational Efficiency THE FIRST EVER CLOSED MIXING SYSTEM. Innovation that is changing the world of liquid mixing. A versatile, easy-to-use system that delivers complete mixing and more efficient
More informationAEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration
Commercial Sand Akiki Engineering Series Commercial Sand s are constructed based on efficient and economical method for reducing suspended method down to 40 microns in size on various feed water sources.
More informationEVALUATION SUBJECT: IPEX AQUARISE CPVC HOT- AND COLD- POTABLE WATER DISTRIBUTION SYSTEM
ICC-ES Report PMG-1156 Reissued 08/2018 This report is subject to renewal 08/2019 EVALUATION SUBJECT: IPEX AQUARISE CPVC HOT- AND COLD- POTABLE WATER DISTRIBUTION SYSTEM DIVISION: 22 00 00 PLUMBING SECTION:
More informationwww.polyvalveusa.com 1 Why use Polyvalve Poly-Gas Valves? Polyvalve Poly-Gas valves are everything you d expect from the company that invented polyethylene valves. Millions of Polyvalve Poly-Gas valves
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 185 US Highway 206 Roxbury Township, NJ 07836 973.586.2201 973.586.2243 fax www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower Specifications Pioneer
More informationThe Iron Curtain Filtration System
TM The Iron Curtain Filtration System Chemical Free: No Potassium Permanganate No Salt No Chlorine Guards Against: Iron Stains Iron Tasting Water Rotten Egg Odor U.S. Patent No.: B1 5,096,596 Hellenbrand
More informationSECTION 5 E-Treat Water Conditioning Systems
SECTION 5 E-Treat Water Conditioning Systems WaTEr QualITy PrOduCTS Catalog 10 Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts
More informationPARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )
PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and
More informationFilters & Elements. People. Passion. Performance
Filters & Elements People. Passion. Performance Air Quality Solutions How clean is your compressed air? Atmospheric air naturally contains several impurities such as dust, various forms of hydrocarbons
More informationMission Statement. Profile and History. R.O. UltraTec s Advantages
2005 PRODUCT CATALOG» Reverse Osmosis Systems» Water Coolers» Filter Cartridges» Filter Housings» Filtration Systems & Water Softeners» Membrane Housings» Membranes» Pumps & Motors» Disinfection Equipment
More informationPRESSURE REGULATORS. GUIDE to REGULATORS and SERVO VALVES
Master Pneumatic regulators are made in a wide range of sizes to suit nearly all industrial requirements for pneumatic pressure regulation. Good pressure regulation is essential to the efficient use of
More informationSANITARY CONTROL VALVES & REGULATORS
SANITARY CONTROL VALVES & REGULATORS www.cashco com Innovative Solutions Get Consistent Quality By involving every employee in our ISO 9001:2008 Quality Assurance Program, you can count on the quality
More informationSECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)
SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) PART 1 GENERAL 1.1 SCOPE 1.1.1 The manufacturer shall furnish a low profile, multi-tray Air Stripper for removal of volatile organic
More informationLine filters LINE FILTERS
Line filters LINE FILTERS 4-40 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 90 years of industrial experience. It is our ambition to offer compressed air solutions that
More informationInstallation, Operation, and Maintenance Manual Aquapurion 600 GPD Line Pressure Reverse Osmosis System
Installation, Operation, and Aquapurion 600 GPD Line Pressure Reverse Osmosis System US Water Systems, Inc. 1209 Country Club Road Indianapolis, IN 46234 1-800-608-8792 support@uswatersystems.com www.uswatersystems.com
More informationPioneer Forced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower
More informationFERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS
IRRIGATION EQUIPMENT LTD. FERTILIZER T A N K S SERIES 6000 APPLICATIONS Designed specifically for fertigation in agriculture Simple, efficient and trouble free operation. Standard models apply fertilizer
More informationINIZIATIVE INDUSTRIALI
INIZIATIVE INDUSTRIALI S.p.A. Sarplast is a company located in Santa Luce (Pisa, Italy) which has over 35 years experience in the design, manufacturing and supply of Glass-Fiber Reinforced Plastic (GRP)
More informationSafety Barrier Solutions
S E P A R A T I N G P E O P L E F R O M H A Z A R D S Safety Barrier Solutions NO DRILLING OR WELDING NO HOT WORK PERMIT REQUIRED COST EFFECTIVE MEET SAFETY STANDARDS The Kee Safety Concept KEE SAFETY
More informationFilters & Elements. People. Passion. Performance
Filters & Elements People. Passion. Performance Air Quality Solutions How clean is your compressed air? Atmospheric air naturally contains several impurities such as dust, various forms of hydrocarbons
More informationANDERSON GREENWOOD OS&Y GAUGE VALVES SERIES M5K/M5AK/M5YK
SERIES M5K/M5AK/M5YK Root isolation valves with outside screw and yoke, bolted bonnet construction for pressures up to 6, psi (414 barg) FEATURES M5YK GENERAL APPLICATION M5K-L M5K series gauge valves
More informationProLine Pipes Brochure 2018
ProLine Pipes Brochure 2018 ProLine Pipes With ProLine pipes, EPS Group has introduced the latest high-tensile, high-impact upvc threaded pipes popularly known as column pipes for submersible pumps. ProLine
More informationOBSOLETE. bladder tank assemblies
October 9, 2006 Foam 180a 1. DESCRIPTION The Viking consists of an inner tank (bladder) fabricated of aflexible material (Buna-N over nylon) and an outer tank fabricated from carbon steel. A sight gauge
More informationPit Systems & Accessories. Water Treatment Systems. Mi-T-M Water Treatment Systems provide a better tomorrow by protecting our environment today.
Mi-T-M WATER TREATMENT WATER TREATMENT Water Treatment Mi-T-M Water Treatment provide a better tomorrow by protecting our environment today. Use an in-ground pit system to pre-treat wastewater efficiently
More information3M Purification Inc. 3M High Flow Series Filter Systems
3M Purification Inc. 3M High Flow Series Filter Systems 3M High Flow Series Filter System The 3M High Flow series filter system is an advanced design that uses 3M innovation and 3M Purification Inc. s
More informationImproved Water Quality in the Home
Improved Water Quality in the Home Aqua Flo Point-of-Use 69 Aqua Flo Point-of -Use Water Filters Novo offers a wide range of point-of-use filtration solutions. Aqua Flo Economy - A full line of quality
More informationOutstanding Productivity. Exceptional Results. Tough Truck. Proven Value. Industry Leading. Customer Preferred.
PE 4500 SERIES Tough Truck. Proven Value. The Crown PE 4500 Series delivers proven performance in the toughest applications, making this versatile pallet truck a rock-solid investment in your operational
More informationsanitary control valves & regulators
sanitary control valves & regulators Reputation Built on Quality, Dependability, Service. Get Consistent Quality By involving every employee in our ISO 9001:2000 Quality Assurance Program, you can count
More informationYARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES
Protecting pipeline components from damaging particles with minimal pressure drop FEATURES Body material - ASTM and/or ASME as permitted under boiler code and power piping code. Provides assurance of quality
More informationHIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)
PART 1-GENERAL INTEGRALLY MOLDED FLANGED OUTLET (IMFO ) - COMPLETE DRAIN HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61) 1.01 Requirements 1. The
More informationmott corporation High Purity Products IGS Porous Metal Filters and Flow Restrictors.
mott corporation High Purity Products IGS Porous Metal Filters and Flow Restrictors. IGS Porous Metal Filters and Flow Restrictors. Integrating the best of high flow rates, material range and configuration
More informationFusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units
Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units Clarus Environmental Overview Clarus Environmental is a division of the Zoeller Company, an industry leader in pumps
More informationBetapure CMP Series. CMP Filter Capsules. Superior Reduction Of Large Particle Counts For Improved Yields. Features & Benefits.
Betapure Series Filter Capsules Features & Benefits Graded Porosity Design Superior reduction of hard and soft gel contaminants, for reduced defectivity and improved yields High contaminant holding capacity
More informationTM Series Induced Draft Cooling Tower Specifications
Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com TM Series Induced Draft Cooling
More informationBRUTALLY STRONG AS A RHINO SHOULD BE
BRUTALLY STRONG AS A RHINO SHOULD BE May 2014 DOMESTIC PRODUCT BROCHURE Tank Sizes Rhino s Range of Tanks are available in the sizes listed in the table on the right. All tanks are 2.2 metres high and
More informationIndustrial/Commercial, Hi-Rate, Permanent Media, Filtration Systems. Steel Tank Series S810
Industrial/Commercial, Hi-Rate, Permanent Media, Filtration Systems Steel Tank Series 138 - S810 Industrial/Commercial, Hi-Rate, Permanent Media, Filtration Systems EPD s rugged industrial/commercial,
More informationTRICON DOUBLE-CON PLUS
TRICON DOUBLE-CON PLUS System Specifications Iron Pipe Size Steel Conduit O.D. Steel Conduit Wall Outer Insulation (IN)* Alum./Stainless/Galv. Jacket O.D. (IN) Metal Jacket Wall Thickness 1 4.50.120 1.75
More informationTYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:
Effluent Pumps: Effluent pumps are the pumps most often used in small on-site systems. They are designed to pump effluent, the effluent flowing out of a septic tank. This effluent is relatively clear liquid
More informationAIR OPERATED DOUBLE DIAPHRAGM PUMPS
AIR OPERATED DOUBLE DIAPHRAGM PUMPS PRODUCT CATALOG A REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY
More informationAqua Clear Aqua Clear multi-lobal cross section of individual filaments has more micro-voids giving higher dirt holding capacity and lower resistance
Aqua Clear STRING-WOUND FILTER CARTRIDGES Free of extractables No leaching Twice the life of conventional cartridges Made from continuous filaments No media migration % Polypropylene Wide chemical compatibility
More informationVARIABLE SPEED AND FLOW PUMP
INTELLIPRO VSF INTELLIPRO VSF VARIABLE SPEED AND FLOW PUMP PRECISE FLOW CONTROL FOR THE HIGHEST ENERGY SAVINGS AND ULTIMATE SYSTEM PERFORMANCE. Good things happen when you go with the flow. NEW! THE WORLD
More informationA solution to your outdoor softener installation.
A solution to your outdoor softener installation. Outdoor Culligan Medallist Series Water Softener Exclusive Outdoor Culligan Medallist Series Design Technology The Outdoor Culligan Medallist Series Water
More informationGeneral - Frequently Asked Questions
SIERRA SALES SERVING THE WORLD WITH PE TANKS 215-258-5602 Fax 215-258-5606 http://petanks.com General - Frequently Asked Questions 1. What makes poly tanks a good choice for my chemical storage/application?
More informationTHE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE.
THE STRONGEST, TOUGHEST, MOST FLEXIBLE PIPE. MUNICIPAL SYSTEMS BIONAX PVCO PRESSURE PIPE FOR WATER AND SEWAGE FORCEMAINS, TRANSMISSION AND DISTRIBUTION LINES 4 through 30 (100 to 750 mm) 165, 235 & 305
More informationMiniature I/P, E/P Transducer
Miniature I/P, E/P Transducer Accurate and economical electronic pressure control The Type 550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional
More informationEssex County College - West Essex Campus Addition And Renovations Dib # / SECTION DOMESTIC WATER PIPING SPECIALTIES
Essex County College - West Essex Campus Addition And Renovations Dib # 54292 / 11-14 SECTION 221119 - DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationRelays & Volume Boosters
Relays & Volume Boosters Type 20 Type 20 HR Type 20 EX HR Type 72 Type 72 HR HR Type 79 Type 79 HR www.marshbellofram.com 800.727.5646 37 Relays - Volume Boosters Comparison Chart Maximum Type 20 Type
More informationD-10 OUTLINE SPECIFICATION FOR PRE FAB Undergrd Piping System
D-10 OUTLINE SPECIFICATION FOR PRE FAB Undergrd Piping System PREFABRICATED CONDUIT PIPING SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General
More informationSiphonic. Drain System. Engineered Water Solutions for Today s Building Design Needs
Siphonic Drain System Engineered Water Solutions for Today s Building Design Needs Table of Contents History of Siphonic Systems 2 Components of Siphonic Systems 2 Specifics of Siphonics 2 Conventional
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationECLIPSE. NSF/ANSI 61* *Non-metallic Only EXTERNAL GEAR PUMP ENGINEERED PRODUCTS. Flow: up to 33 gpm (125 lpm)
ECLIPSE EXTERNAL GEAR PUMP Flow: up to 33 gpm (125 lpm) Differential Pressure: up to 15 psi (1.3 bar) Working Pressure: up to 3 psi (2.7 bar) Temperature: from -4 to 45 F (-4 to 232 C) Viscosity: up to
More informationAIR OPERATED GAS BOOSTERS
DESIGNER AND MANUFACTURER OF HYDRAULIC AND PNEUMATIC EQUIPMENT SC HYDRAULIC ENGINEERING CORPORATION AIR OPERATED GAS BOOSTERS A High Pressure History An innovator and pioneer in the field of hydraulic
More informationA REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY
AIR OPERATED DOUBLE DIAPHRAGM PUMPS PRODUCT CATALOG A REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY
More information