For inspection purposes only.

Size: px
Start display at page:

Download "For inspection purposes only."

Transcription

1 ISO/IEC Accredited Legal Entity, UKAS Accredited Testing Laboratory No Exova (UK) Ltd trading as Exova Catalyst & Exova Catalyst Ireland Unit C5, Emery Court, The Embankment Business Park, Stockport, SK4 3GL 70 Montrose Avenue, Hillington Park, Glasgow, G52 4LA T: (or from overseas) E: john.healey@exova.com Your Exova Catalyst Ireland Contact: John Healey ( ) Stack Emissions Testing Report Commissioned by Fingal Timoney & Company Installation Name & Address Landfill Site Lusk Dublin Industrial Emissions Licence: W Stack Reference Dates of the Monitoring Campaign 18th October 2016 Job Reference Number CEK2280 Report Written by Stephen Dick Team Leader MCERTS Level 2 MM TE1 TE2 TE3 TE4 Report Approved by John Healey Regional Manager MCERTS Level 2 MM TE1 TE2 TE3 TE4 Report Date 11th November 2016 Version Version 2 Signature of Report Approver CATRT (Version BP) CEK2280 Fehily Timoney & Co ( Landfill) Report v2 EPA Export :14:57:11

2 CONTENTS TITLE PAGE CONTENTS Summary of Sampling Deviations 2 EXECUTIVE SUMMARY Monitoring Objectives Monitoring Results Monitoring Dates & Times Process Details Monitoring & Analytical Methods Sampling Location Plant Photos / Sample Points APPENDIX 1 Monitoring Personnel & List of Equipment APPENDIX 2 Raw Data, Sampling Equations & Charts Opinions and interpretations expressed herein are outside the scope of Exova Catalyst Ireland's ISO accreditation. This test report shall not be reproduced, except in full, without the written approval of Exova Catalyst Ireland. The testing performed fully meets the technical requirements in Irish EPA Guidance Note, AG2. This version of the test report supersedes the previous version of the test report. Please destroy all previous versions to ensure no confusion arises from having multiple test reports in existence. CATRT (Version BP) Page 2 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:11 Industrial Emissions Licence: W000903

3 Executive Summary (Page 1 of 7) MONITORING OBJECTIVES, 18th October 2016 Overall Aim of the Monitoring Campaign Exova Catalyst Ireland were commissioned by Fingal Timoney & Company to carry out stack emissions testing for Fingal County Council on the at. The aim of the monitoring campaign was to demonstrate compliance with a set of emission limit values (ELVs) as specified in the Site's Permit. Special Requirements There were no special requirements. Target s Hydrogen Fluoride Hydrogen Chloride TA Luft Class I TA Luft Class II TA Luft Class III Oxides of Nitrogen (as NO₂) Carbon Monoxide CATRT (Version BP) Page 3 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:11 Industrial Emissions Licence: W000903

4 Executive Summary (Page 2 of 7) MONITORING RESULTS, where MU = Measurement Uncertainty associated with the Result Concentration Mass Emission Hydrogen Fluoride ¹ g/hr Hydrogen Chloride ¹ g/hr TA Luft Class I ¹ g/hr TA Luft Class II ¹ < g/hr < TA Luft Class III ¹ < g/hr < Oxides of Nitrogen (as NO₂) ¹ g/hr Carbon Monoxide ¹ g/hr Oxygen Water Vapour Stack Gas Temperature Stack Gas Velocity Volumetric Flow Rate (ACTUAL) Volumetric Flow Rate (REF) ¹ Dry 5.48 NOTE: VOLUMETRIC FLOW RATE & VELOCITY DATA TAKEN FROM THE PRELIMINARY VELOCITY TRAVERSE. ¹ Reference Conditions (REF) are: 273K, 101.3kPa, dry gas, 5% oxygen. % v/v % v/v C m/s * The MU is calculated from values in LFTGN 08 [2010]. i.e. 20% of the Result for CO, 30% of the Result for NOx & 40% of the Result for TVOCs) 13.4 m³/hr 7912 m³/hr Result ** The result is considered to be an 'Approach to Limit' if it is above the Limit, but below the Limit once the MU is subtracted from it. The Result is considered to be NonCompliant if, even after subtracting the MU from the Result, the Result is still above the Limit in LFTGN 08 [2010] or the calculated MU (See the Measurement Uncertainty Calculations in Appendix 2 of this Test Report) is above 6% for CO, 10% for NOx & 15% for TVOCs MU * +/ +/ Limit ** 4500 Result MU Limit CATRT (Version BP) Page 4 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:11 Industrial Emissions Licence: W000903

5 Executive Summary (Page 3 of 7) MONITORING DATE(S) & TIMES, 18th October 2016 Concentration Mass Emission Sampling Date(s) Sampling Times Duration mins Hydrogen Fluoride R g/hr /10/ :05 14:35 30 Hydrogen Chloride R g/hr /10/ :30 14:00 30 TA Luft Class I R g/hr /10/ :17 14:17 60 TA Luft Class II R1 < 1.42 g/hr < /10/ :17 14:17 60 TA Luft Class III R1 < 1.42 g/hr < /10/ :17 14:17 60 Oxides of Nitrogen (as NO₂) R g/hr /10/ :20 14:20 60 Carbon Monoxide R g/hr /10/ :20 14:20 60 Oxygen R1 % v/v /10/ :20 14:20 60 Velocity & Volumetric Flow Rate R1 18/10/ :05 13:10 All results are expressed at the respective reference conditions. CATRT (Version BP) Page 5 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:11 Industrial Emissions Licence: W000903

6 Executive Summary (Page 4 of 7) PROCESS DETAILS, 18th October 2016 Standard Operating Conditions Process Status Capacity (of 100%) and Tonnes / Hour Continuous or Batch Process Feedstock (if applicable) Abatement System Abatement System Running Status Fuel Plume Appearance Value Power Generation Max 1000KW / Operating 500KW Continuous N/A N/A N/A Landfill gas None Visible CATRT (Version BP) Page 6 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:11 Industrial Emissions Licence: W000903

7 Executive Summary (Page 5 of 7) MONITORING & ANALYTICAL METHODS, 18th October 2016 Monitoring Analysis Standard Technical Procedure ISO Testing Testing Lab Analytical Procedure Analytical Technique ISO Analysis Analysis MCERTS Lab Testing LOD (Average) Hydrogen Fluoride ISO CATTP10 Yes CAT CATAP01 IC Yes CAT Yes Hydrogen Chloride EN 1911 TA Luft Class I CEN/TS TA Luft Class II CEN/TS TA Luft Class III CEN/TS Water Vapour EN Oxides of Nitrogen (as NO₂) Carbon Monoxide Oxygen EN EN CATTP11 CATTP16 CATTP16 CATTP16 CATTP05 CATTP21 CATTP21 Velocity & Vol. Flow Rate EN (MID) CATTP41 Yes CAT Yes CAT CATAP017 IC Yes CAT Yes Yes CAT M109(N) GC MS No RPS No Yes CAT M109(N) GC MS No RPS No Yes CAT M109(N) GC MS No Yes CAT CATTP05 Gravimetric Yes Yes CAT Chemiluminescence by Horiba PG250 Yes CAT NDIR by Horiba PG250 EN CATTP21 Yes CAT Dry Zirconia Cell by Horiba PG250 ANALYSIS LABORATORIES Pitot Tube and Thermocouple (with short name reference as appears in the table above) Exova Catalyst (CAT) ISO Accreditation Number: 4279 RPS Laboratories Ltd (RPS) ISO Accreditation Number: 0605 SUMMARY OF SAMPLING DEVIATIONS Run Deviation All s All There are no deviations associated with the sampling employed. RPS No CAT Yes 0.1 % v/v Yes 0.41 Yes 0.62 Yes 0.1 % Yes 1.2 m/s CATRT (Version BP) Page 7 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:11 Industrial Emissions Licence: W000903

8 Executive Summary (Page 6 of 7) SUITABILITY OF SAMPLING LOCATION Duct Characteristics Location of Sampling Platform Value General Platform Information Value Type Depth Width Area Port Depth Orientation of Duct Sample Port Size m m m² cm Circular Vertical 4" BSP Permanent / Temporary Platform Inside / Outside On Roof Outside Platform Details Irish EPA Technical Guidance Note AG1 / EN Platform Requirements Value Sufficient working area to manipulate probe and operate the measuring instruments Platform has 2 levels of handrails (approx. 0.5m & 1.0m high) Platform has vertical base boards (approx. 0.25m high) Platform has chains / self closing gates at top of ladders There are no obstructions present which hamper insertion of sampling equipment Safe Access Available Easy Access Available Sampling Location / Platform Improvement Recommendations All platforms should be designed in accordance with the requirements in EPA Guidance Note AG1 and EN EN Homogeneity Test Requirements There is no requirement to perform a EN Homogeneity Test on this Stack. No No No No Yes Yes Yes Sampling Plane Validation Criteria (from EN 15259) Criteria in EN Traverse 1 Required Compliant Lowest Differential Pressure Pa > 5 Pa Yes Mean Velocity m/s Lowest Gas Velocity m/s Highest Gas Velocity m/s Ratio of Above : < 3 : 1 Yes Maximum Angle of Swirl NM NM NM NM NM NM NM No Local Negative Flow Yes Yes Where NM = Not Measured as no Isokinetic sampling was performed. CATRT (Version BP) Page 8 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:11 Industrial Emissions Licence: W000903

9 Executive Summary (Page 7 of 7) PLANT PHOTOS Photo 1 Photo 2 Photo 3 SAMPLE POINTS A1 Line A where = isokinetic point sampled at = isokinetic point not sampled at = combustion gases sample point = nonisokinetic sample point CATRT (Version BP) Page 9 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

10 APPENDICES APPENDIX CONTENTS APPENDIX 1 Stack Emissions Monitoring Personnel, List of Equipment & Methods and Technical Procedures Used APPENDIX 2 Summaries, Calculations, Raw Data and Charts CATRT (Version BP) Page 10 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

11 APPENDIX 1 STACK EMISSIONS MONITORING PERSONNEL Position Name MCERTS Accreditation MCERTS Number Technical Endorsements Team Leader Stephen Dick MCERTS Level 2 MM TE1 TE2 TE3 TE4 Trainee Kyle Barbour MCERTS Trainee MM None LIST OF EQUIPMENT Extractive Sampling Instrumental Analysers Miscellaneous Items Equipment Type Equipment I.D. Equipment Type Equipment I.D. Equipment Type Equipment I.D. Control Box DGM (1) CAT 7.38 Horiba PG250 CAT 9.10 Digital Manometer (1) CAT 3.54 Control Box DGM (2) Horiba PG350E Digital Manometer (2) CAT 3.34 Box Thermocouples (1) CAT 3.57 Servomex 4900 Digital Temperature Meter CAT 3.34 / 3.54 Box Thermocouples (2) Eco Physics CLD 822Mh Stopwatch CAT Umbilical (1) CAT 3.57 ABB AO2020URAS26 Barometer CAT Umbilical (2) Servomex 5200MP Stack Thermocouple (1) CAT Oven Box (1) CAT JCT JCC P1 Cooler CAT Stack Thermocouple (2) CAT Oven Box (2) Gasmet DX4000 Stack Thermocouple (3) Heated Probe (1) CAT 5.4 Gasmet Sampling System 1m Heated Line (1) Heated Probe (2) CAT 5.8 Bernath 3006 FID CAT 8.4 1m Heated Line (2) Heated Probe (3) CAT 5.11 Ankersmid APP100 CAT m Heated Line (3) SPitot (1) CAT 21P.33 Mass Flow Controller (1) CAT m Heated Line (1) CAT 20.4 SPitot (2) CAT 21S.28 / 21S.4 Mass Flow Controller (2) CAT m Heated Line (1) LPitot Mass View (1) CAT m Heated Line (1) CAT 20.8 Site Balance CAT 14.4 Mass View (2) CAT m Heated Line (2) 500g / 1Kg Check Weights CAT 17.4 Easylogger ENEL12 Bit CAT 11.6 Dual Channel Heater Controller CAT 3.15 Last Impinger Arm CAT 4.22 / 4.44 / Easylogger ENEL12 Bit CAT Single Channel Heater Controller Callipers CAT Bioaerosols Temperature Logger Laboratory Balance Tubes Kit Thermocouple Electronic Refrigerator Tape Measure CAT 16.3 Hydrogen Fluoride Hydrogen Chloride TA Luft Class I TA Luft Class II TA Luft Class III Water Vapour Oxides of Nitrogen (as NO₂) Carbon Monoxide Oxygen Velocity & Vol. Flow Rate METHODS & TECHNICAL PROCEDURES USED Standard ISO EN 1911 CEN/TS CEN/TS CEN/TS EN EN EN EN EN (MID) Technical Procedure CATTP10 CATTP11 CATTP16 CATTP16 CATTP16 CATTP05 CATTP21 CATTP21 CATTP21 CATTP41 CATRT (Version BP) Page 11 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

12 PRELIMINARY STACK SURVEY: CALCULATIONS General Stack Details Stack Details (from Traverse) Stack Diameter / Depth, D Stack Width, W Stack Area, A Average Stack Gas Temperature, T a Average Stack Gas Pressure Average Stack Static Pressure, P static Average Barometric Pressure, P b Average Pitot Tube Calibration Coefficient, C p m m m² C Pa kpa kpa Value Stack Gas Composition & Molecular Weights Component Conc ppm Conc Dry % v/v Conc Wet % v/v Volume Fraction r Molar Mass M Density kg/m³ p Conc kg/m³ p i CO₂ (Estimated) O₂ N₂ Moisture (H₂O) Where: p = M / p i = r x p Calculation of Stack Gas Densities Determinand Dry Density (STP), P STD Wet Density (STP), P STW Dry Density (Actual), P Actual Average Wet Density (Actual), P ActualW kg/m³ Result kg/m³ kg/m³ kg/m³ Where: P STD = sum of component concentrations, kg/m³ (not including water vapour) P STW = sum of all wet concentrations / 100 x density, kg/m³ (including water vapour) P Actual = P STD x (T STP / (P STP )) x ((P static + P b ) / T a ) P ActualW (at each sampling point) = P STW x (T s / P s ) x (P a / T a ) Calculation of Stack Gas Volumetric Flowrate, Q Duct gas flow conditions Temperature Total Pressure Moisture Oxygen (Dry) C kpa % % Actual REF ¹ Gas Volumetric Flowrate (from Traverse) Result Gas Volumetric Flowrate (Actual) Gas Volumetric Flowrate (STP, Wet) Gas Volumetric Flowrate (STP, Dry) Gas Volumetric Flowrate REF ¹ m³/hr m³/hr m³/hr m³/hr CATRT (Version BP) Page 12 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

13 PRELIMINARY STACK SURVEY: VELOCITY TRAVERSE TO EN (MID) (1 of 1) Value Value Date of Survey 18/10/2016 Initial Pitot Leak Check Time of Survey 13:05 13:10 Final Pitot Leak Check Atmospheric Pressure kpa Orientation of Duct Average Stack Static Pressure Pa 36 Pitot Tube, C p Result of Pitot Stagnation Test Pass Number of Lines Available Are Water Droplets Present? No Number of Lines Used Device Used SType Pitot with KIMO MP 200 (500Pa) Sampling Line A Traverse Depth P Temp Wet Density Velocity Swirl Point m Pa C kg/m³ m/s STATIC (: Pa) 36.0 Mean Pass Pass Vertical CATRT (Version BP) Page 13 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

14 PRELIMINARY STACK SURVEY: VELOCITY TRAVERSE TO EN (MID) MEASUREMENT UNCERTAINTY (1 of 1) Performance characteristics (Uncertainty Components) Standard Uncertainty on the coefficient of the Pitot Tube Standard Uncertainty associated with the mean local dynamic pressures Resolution Calibration Drift Lack of Fit Overall corrections to dynamic measurements Standard uncertainty associated with the molar mass of the gas φo₂,w φco₂,w Oxygen, dry Carbon Dioxide, dry Water Vapour Oxygen, wet Carbon Dioxide, wet Standard uncertainty associated with the stack temperature Standard uncertainty associated with the absolute pressure in the duct Atmospheric Pressure Static Pressure Standard uncertainty associated with the density in the duct Standard uncertainty associated with the local velocities Standard uncertainty associated with the mean velocity Standard uncertainty associated with the mean velocity (95% Confidence) Standard uncertainty associated with the mean velocity (95% Confidence), relative Standard uncertainty associated with the volume flow rate (95% Confidence) u²(a)/a² u²(qv,w)/q²v,w u²(qv,w) u(qv,w) Standard uncertainty associated with the volume flow rate (95% Confidence), relative Uncertainty Value u(k) u( pi) Pa u(res) u(cal) u(drift) u(fit) u(cf) u(m) u(φo₂,d) u(φco₂,d) u(φh₂o) u(φo₂,w) u(φco₂,w) u(tc) K u(pc) Pa u(patm) u(pstat) u(ρ) u(vi) Pa u(v) m/s Uc(v) m/s Uc,rel(v) 3.51 % Uc(qV,w) m³/hr Uc,rel(qV,w) 5.73 % CATRT (Version BP) Page 14 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

15 HYDROGEN FLUORIDE: RESULTS SUMMARY, Sample Runs Mean Concentration Uncertainty Mass Emission ± g/hr Uncertainty ±g/hr Mean Water Vapour % v/v Uncertainty ±% v/v Blank Runs Concentration General Sampling Information Standard Technical Procedure Name of Analytical Laboratory Analytical Laboratory's Procedure ISO Accredited Analysis? Date of Sample Analysis Probe Material Filter Housing Material Impinger Material Absorption Solution Positioning of Filter Filter Size and Material Blank 1 Maximum < 0.05 < 0.05 Value ISO CATTP10 CAT CATAP01 Yes 02/11/2016 Quartz Quartz Glass Polyethylene 0.1 mol/l Sodium Hydroxide Out Stack 0.1μm Glass Fibre Number of Sampling Lines Used 1 / 1 Number of Sampling Points Used 1 / 1 FORMAT: Number Used / Number Required FORMAT: Number Used / Number Required Sample Point I.D.'s A1 Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 15 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

16 HYDROGEN FLUORIDE: SAMPLING DETAILS Sample Runs Sampling Times 14:05 14:35 Sampling Dates 18/10/2016 Sampling Device DGM Duration mins 30 DGM Start Volume m³ DGM End Volume m³ DGM Start Temperature C 15.0 DGM End Temperature C 15.0 Start H mmh₂o 15.0 End H mmh₂o 15.0 DGM Y d Barometric Pressure kpa Volume Sampled (STP, Dry) m³ Volume Sampled (STP, Wet) m³ Volume Sampled (REF) m³ Sample Flow Rate l/min Laboratory Result for Front Impingers Laboratory Result for Back Impinger Volume in Front Impingers Volume in Back Impinger /ml /ml ml ml Mass in Front Impingers Mass in Back Impinger < 7.8 Total Mass Collected Calculated Concentration 1.79 Liquid Trap Start Mass g Liquid Trap End Mass g Silica Trap Start Mass g Silica Trap End Mass g Total Mass Of Water Vapour g 42.7 Calculated Water Vapour % v/v Where: DGM stands for Dry Gas Meter Blank Runs Blank 1 Blank Dates 18/10/2016 Average Volume Sampled (REF) m³ Laboratory Result for Impingers Volume in Impingers Total Mass Collected Calculated Concentration /ml ml < < 15.7 < 0.05 CATRT (Version BP) Page 16 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

17 HYDROGEN FLUORIDE: QUALITY ASSURANCE Sample Runs Leak Test Results Mean Sampling Rate l/min PreSampling Leak Rate l/min 0.06 PostSampling Leak Rate l/min 0.11 Allowable Leak Rate l/min 0.23 Leak Test Acceptable Yes Absorption Efficiency Absorption Efficiency % Allowable Absorption Efficiency % 95 Absorption Efficiency Acceptable Yes Water Droplets Are Water Droplets Present No MU (Concurrent Water Vapour) Measurement Uncertainty (MU) % 5.1 Allowable MU % 20 MU Acceptable % Yes Silica Gel (Concurrent Water Vapour) Less than 50% Faded % Yes Test Conditions Ambient Temperature Recorded? Yes Blank Runs Leak Test Results Blank 1 Expected Sampling Rate l/min PreSampling Leak Rate l/min 0.08 PostSampling Leak Rate l/min 0.10 Allowable Leak Rate l/min 0.20 Leak Test Acceptable Yes Validity of Blank vs ELV Blank 1 Allowable Blank 0.5 Blank Acceptable Yes Method Deviations Nature of Deviation (x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run) 1 Run Number There are no deviations associated with the sampling employed. x x CATRT (Version BP) Page 17 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

18 HYDROGEN FLUORIDE: MEASUREMENT UNCERTAINTY CALCULATIONS Value Measured Quantities Symbol Symbol Standard uncertainty Sampled Volume (Actual) Sampled Gas Temperature Sampled Gas Pressure Sampled Gas Humidity Leak Laboratory Result V m uv m m³ T m ut m K 2.0 ρ m uρ m kpa 0.5 H m 0.0 uh m % v/v 1.0 L 0.97 ul % L r 2.65 ul r % Uncertainty as a Percentage Measured Quantities Requirement of Standard Sampled Volume (Actual) Sampled Gas Temperature Sampled Gas Pressure Sampled Gas Humidity Leak Laboratory Result % % % % % % % % % % % 2.65 No Requirement Measured Quantities Symbol Sampled Volume (STP) Leak Laboratory Result Sampled Volume (STP) Leak Laboratory Result Uncertainty in Measurement V m m³ L L r Measured Quantities Measured Quantities Uncertainty in Result Oxygen Correction Part of MU Budget Sensitivity Coefficient O₂ Correction Factor Stack Gas O₂ Content MU for O₂ Correction Overall MU For O₂ Measurement 1.04 % v/v % 3.24 Combined uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty % % % % CATRT (Version BP) Page 18 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

19 HYDROGEN CHLORIDE: RESULTS SUMMARY, Sample Runs Mean Concentration Uncertainty ± Mass Emission g/hr Uncertainty ±g/hr Water Vapour Mean % v/v Uncertainty ±% v/v Blank Runs Blank 1 Maximum Concentration < 0.05 < 0.05 General Sampling Information Value Standard EN 1911 Technical Procedure CATTP11 Name of Analytical Laboratory Analytical Laboratory's Procedure ISO Accredited Analysis? Date of Sample Analysis Probe Material Filter Housing Material Impinger Material Absorption Solution Positioning of Filter Filter Size and Material Number of Sampling Lines Used Number of Sampling Points Used Sample Point I.D.'s CAT CATAP017 Yes 03/11/2106 Titanium Titanium Borosilicate Glass HPLC Grade Water Out Stack 0.1μm Glass Fibre 1 / 1 1 / 1 A1 FORMAT: Number Used / Number Required FORMAT: Number Used / Number Required Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 19 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

20 HYDROGEN CHLORIDE: SAMPLING DETAILS Sample Runs Sampling Times 13:30 14:00 Sampling Dates 18/10/2016 Sampling Device DGM Duration mins 30 DGM Start Volume m³ DGM End Volume m³ DGM Start Temperature C 14.0 DGM End Temperature C 15.0 Start H mmh₂o 15.0 End H mmh₂o 15.0 DGM Y d Barometric Pressure kpa Volume Sampled (STP, Dry) m³ Volume Sampled (STP, Wet) m³ Volume Sampled (REF) m³ Sample Flow Rate l/min Laboratory Result for Front Impingers Laboratory Result for Back Impinger Volume in Front Impingers Volume in Back Impinger /ml /ml ml ml Mass in Front Impingers Mass in Back Impinger 11.6 Total Mass Collected Calculated Concentration 1.00 Liquid Trap Start Mass g Liquid Trap End Mass g Silica Trap Start Mass Silica Trap End Mass Total Mass Of Water Vapour g g Calculated Water Vapour % v/v g Where: DGM stands for Dry Gas Meter Blank Runs Blank 1 Blank Dates Average Volume Sampled (REF) Laboratory Result for Impingers Volume in Impingers Total Mass Collected Calculated Concentration 18/10/2016 m³ /ml < 0.05 ml < 15.7 < 0.05 CATRT (Version BP) Page 20 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

21 HYDROGEN CHLORIDE: QUALITY ASSURANCE Sample Runs Leak Test Results Mean Sampling Rate l/min PreSampling Leak Rate l/min 0.10 PostSampling Leak Rate l/min 0.11 Allowable Leak Rate l/min 0.23 Leak Test Acceptable Yes Absorption Efficiency Absorption Efficiency % 96.5 Allowable Absorption Efficiency % N/A ¹ Absorption Efficiency Acceptable N/A ¹ ¹ The concentration in the last absorber was less than 5 times the analytical detection limit Water Droplets Are Water Droplets Present No MU (Concurrent Water Vapour) Measurement Uncertainty (MU) % 5.1 Allowable MU % 20 MU Acceptable % Yes Silica Gel (Concurrent Water Vapour) Less than 50% Faded % Yes Test Conditions Ambient Temperature Recorded? Blank Runs Leak Test Results Yes Blank 1 Expected Sampling Rate PreSampling Leak Rate PostSampling Leak Rate Allowable Leak Rate Leak Test Acceptable l/min l/min 0.08 l/min 0.10 l/min 0.20 Yes Validity of Blank vs ELV Blank 1 Allowable Blank 5.0 Blank Acceptable Yes Method Deviations Nature of Deviation (x = deviation applies to the associated run, wx = deviation also applies to the concurrent water vapour run) 1 Run Number There are no deviations associated with the sampling employed. wx CATRT (Version BP) Page 21 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

22 HYDROGEN CHLORIDE: MEASUREMENT UNCERTAINTY CALCULATIONS Measured Quantities Symbol Value Symbol Standard uncertainty Sampled Volume (Actual) Sampled Gas Temperature Sampled Gas Pressure Sampled Gas Humidity Leak Laboratory Result V m T m ρ m H m L 0.94 L r 2.50 uv m m³ ut m K 2.0 uρ m kpa 0.5 uh m % v/v 1.0 ul % ul r % Uncertainty as a Percentage Measured Quantities Requirement of Standard Sampled Volume (Actual) Sampled Gas Temperature Sampled Gas Pressure Sampled Gas Humidity Leak Laboratory Result % 2.00 % 0.70 % 0.49 % 1.00 % 0.94 % % 1% 1% 1% 2% No Requirement Measured Quantities Sampled Volume (STP) Leak Laboratory Result Measured Quantities Sampled Volume (STP) Leak Laboratory Result Symbol V m L L r Uncertainty in Measurement m³ Uncertainty in Result Sensitivity Coefficient Oxygen Correction Part of MU Budget Measured Quantities O₂ Correction Factor Stack Gas O₂ Content MU for O₂ Correction Overall MU For O₂ Measurement 1.03 % v/v % 3.23 Combined uncertainty 0.04 Expanded uncertainty (95% confidence) Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty Expanded uncertainty (95% confidence) Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty % 7.0 % 7.7 % 7.7 % 7.7 CATRT (Version BP) Page 22 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

23 TA LUFT CLASS I : RESULTS SUMMARY, Sample Runs Mean Toluene Total General Sampling Information Standard Technical Procedure Value CEN/TS CATTP16 Name of Analytical Laboratory RPS Analytical Laboratory's Procedure M109(N) ISO Accredited Analysis? See Executive Summary Date of Sample Analysis 08/11/2016 Probe Material Stainless Steel Sample Tube Type Coconut Shell Charcoal Dynamic Dilution Employed Yes Number of Sampling Lines Used 1 / 1 Number of Sampling Points Used Sample Point I.D.'s Reference Conditions 1 / 1 Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. A1 FORMAT: Number Used / Number Required FORMAT: Number Used / Number Required CATRT (Version BP) Page 23 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

24 TA LUFT CLASS I : SAMPLING DETAILS RUN 1 Value Sampling Times 13:17 14:17 Sampling Dates 18/10/2016 Sampling Device MV Duration mins 60 N₂ to Stack Gas Dilution Ratio : 1 4 Volume Sampled (REF) m³ Where: MV stands for Mass View (Mass Flow Controller Technology) Toluene Total Lab Result (Front) Lab Result (Back) Lab Result (Total) LOD (Front) LOD (Back) LOD (Total) Concentration Reported Concentration (Blank Reviewed) Reported LOD Adsorption Efficiency % 7.0 < Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 24 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

25 TA LUFT CLASS I : SAMPLING DETAILS BLANK 1 Value Sampling Dates 18/10/2016 Sampling Device MV Average Volume Sampled (REF) m³ Where: MV stands for Mass View (Mass Flow Controller Technology) Lab Result (Front) Lab Result (Back) Lab Result (Total) Concentration Toluene < 5.0 < < Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 25 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

26 TA LUFT CLASS I : QUALITY ASSURANCE (PAGE 1 OF 2) Sample Runs Leak Test Results Mean Sampling Rate PreSampling Leak Rate PostSampling Leak Rate Allowable Leak Rate Leak Test Acceptable Adsorption Efficiency l/min l/min l/min l/min Yes Toluene % Allowable Adsorption Efficiency % Adsorption Efficiency Acceptable #REF! Temperature at Sample Tubes Temperature Allowable Temperature Temperature Acceptable Test Conditions Ambient Temperature Recorded? C 14 C 40 Yes Yes CATRT (Version BP) Page 26 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

27 TA LUFT CLASS I : QUALITY ASSURANCE (PAGE 2 OF 2) Blank Runs Leak Test Results Blank 1 Expected Sampling Rate Sampling Leak Rate l/min l/min Allowable Leak Rate l/min Leak Test Acceptable Yes Validity of Blank vs ELV Blank 1 Allowed Allowable for Toluene 1.4 N/A Allowable for TOTAL Method Deviations Nature of Deviation (x = deviation applies to the associated run) There are no deviations associated with the sampling employed. 1 x Run Number CATRT (Version BP) Page 27 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

28 TA LUFT CLASS I : MEASUREMENT UNCERTAINTY CALCULATIONS Measured Quantities Symbol Value Symbol Standard uncertainty Sampled Volume (STP) Leak Laboratory Result V m L L r uv m ul ul r m³ % % Uncertainty as a Percentage Measured Quantities Requirement of Standard Sampled Volume (STP) Leak Laboratory Result % 2.00 % 0.00 % % 5% No Requirement Measured Quantities Symbol Uncertainty in Measurement Sensitivity Coefficient Sampled Volume (STP) Leak Laboratory Result Measured Quantities Sampled Volume (STP) Leak Laboratory Result O₂ Correction Factor Stack Gas O₂ Content MU for O₂ Correction V m m³ L L r Measured Quantities Uncertainty in Result Oxygen Correction Part of MU Budget 1.03 % v/v Overall MU For O₂ Measurement % Combined uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty NOTE: Uncertainties reported in mg/m ³ are based upon the summation of all Speciated VOCs Measured % 20.0 % 20.0 % 20.0 % 20.0 CATRT (Version BP) Page 28 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

29 TA LUFT CLASS II : RESULTS SUMMARY, Sample Runs Mean TA Luft Class II < 1.42 < 1.42 Total < 1.42 < 1.42 General Sampling Information Value Standard CEN/TS Technical Procedure CATTP16 Name of Analytical Laboratory Analytical Laboratory's Procedure ISO Accredited Analysis? Date of Sample Analysis RPS M109(N) See Executive Summary 08/11/2016 Probe Material Stainless Steel Sample Tube Type Coconut Shell Charcoal Dynamic Dilution Employed Yes Number of Sampling Lines Used Number of Sampling Points Used 1 / 1 1 / 1 FORMAT: Number Used / Number Required FORMAT: Number Used / Number Required Sample Point I.D.'s Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. A1 CATRT (Version BP) Page 29 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

30 TA LUFT CLASS II : SAMPLING DETAILS RUN 1 Value Sampling Times 13:17 14:17 Sampling Dates 18/10/2016 Sampling Device MV Duration mins 60 N₂ to Stack Gas Dilution Ratio : 1 4 Volume Sampled (REF) m³ Where: MV stands for Mass View (Mass Flow Controller Technology) Lab Result (Front) Lab Result (Back) Lab Result (Total) LOD (Front) TA Luft Class II < 5.0 < < < Total < < LOD (Back) LOD (Total) Concentration Reported Concentration (Blank Reviewed) Reported LOD Adsorption Efficiency % Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 30 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

31 TA LUFT CLASS II : SAMPLING DETAILS BLANK 1 Value Sampling Dates 18/10/2016 Sampling Device MV Average Volume Sampled (REF) m³ Where: MV stands for Mass View (Mass Flow Controller Technology) Lab Result (Front) Lab Result (Back) Lab Result (Total) Concentration TA Luft Class II < 5.0 < < Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 31 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

32 TA LUFT CLASS II : QUALITY ASSURANCE (PAGE 1 OF 2) Sample Runs Leak Test Results Mean Sampling Rate l/min PreSampling Leak Rate l/min PostSampling Leak Rate l/min Allowable Leak Rate l/min Leak Test Acceptable Yes Adsorption Efficiency TA Luft Class II % Allowable Adsorption Efficiency % 95 Adsorption Efficiency Acceptable #REF! Temperature at Sample Tubes Temperature C 14 Allowable Temperature C 40 Temperature Acceptable Yes Test Conditions Ambient Temperature Recorded? Yes CATRT (Version BP) Page 32 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

33 TA LUFT CLASS II : QUALITY ASSURANCE (PAGE 2 OF 2) Blank Runs Leak Test Results Blank 1 Expected Sampling Rate l/min Sampling Leak Rate l/min Allowable Leak Rate l/min Leak Test Acceptable Yes Validity of Blank vs ELV Allowable for TA Luft Class II Allowable for TOTAL Blank 1 Allowed 1.4 ###### Method Deviations Nature of Deviation (x = deviation applies to the associated run) There are no deviations associated with the sampling employed. 1 x Run Number CATRT (Version BP) Page 33 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

34 TA LUFT CLASS II : MEASUREMENT UNCERTAINTY CALCULATIONS Measured Quantities Symbol Value Symbol Standard uncertainty Sampled Volume (STP) Leak Laboratory Result V m uv m m³ 0.0 L ul % L r ul r % Measured Quantities Uncertainty as a Percentage Requirement of Standard Sampled Volume (STP) Leak Laboratory Result % % % % % No Requirement Measured Quantities Symbol Sampled Volume (STP) Leak Laboratory Result Sampled Volume (STP) Leak Laboratory Result V m m³ L Measured Quantities Measured Quantities O₂ Correction Factor Stack Gas O₂ Content MU for O₂ Correction Overall MU For O₂ Measurement Uncertainty in Measurement L r % v/v % 3.22 Uncertainty in Result Oxygen Correction Part of MU Budget Sensitivity Coefficient Combined uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty NOTE: Uncertainties reported in mg/m ³ are based upon the summation of all Speciated VOCs Measured % 20.0 % 20.0 % 20.0 % 20.0 CATRT (Version BP) Page 34 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

35 TA LUFT CLASS III : RESULTS SUMMARY, Sample Runs Mean TA Luft Class III < 1.42 < 1.42 Total < 1.42 < 1.42 General Sampling Information Standard Technical Procedure Value CEN/TS CATTP16 Name of Analytical Laboratory RPS Analytical Laboratory's Procedure M109(N) ISO Accredited Analysis? See Executive Summary Date of Sample Analysis 08/11/2016 Probe Material Stainless Steel Sample Tube Type Coconut Shell Charcoal Dynamic Dilution Employed Yes Number of Sampling Lines Used Number of Sampling Points Used 1 / 1 1 / 1 FORMAT: Number Used / Number Required FORMAT: Number Used / Number Required Sample Point I.D.'s Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. A1 CATRT (Version BP) Page 35 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

36 TA LUFT CLASS III : SAMPLING DETAILS RUN 1 Value Sampling Times 13:17 14:17 Sampling Dates 18/10/2016 Sampling Device MV Duration mins 60 N₂ to Stack Gas Dilution Ratio : 1 4 Volume Sampled (REF) m³ Where: MV stands for Mass View (Mass Flow Controller Technology) Lab Result (Front) Lab Result (Back) Lab Result (Total) LOD (Front) LOD (Back) LOD (Total) Concentration Reported Concentration (Blank Reviewed) Reported LOD TA Luft Class III < 5.0 < < < Total < < Adsorption Efficiency % Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 36 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

37 TA LUFT CLASS III : SAMPLING DETAILS BLANK 1 Value Sampling Dates 18/10/2016 Sampling Device MV Average Volume Sampled (REF) m³ Where: MV stands for Mass View (Mass Flow Controller Technology) Lab Result (Front) Lab Result (Back) Lab Result (Total) Concentration TA Luft Class III < 5.0 < < Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 37 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

38 TA LUFT CLASS III : QUALITY ASSURANCE (PAGE 1 OF 2) Sample Runs Leak Test Results Mean Sampling Rate l/min PreSampling Leak Rate l/min PostSampling Leak Rate l/min Allowable Leak Rate l/min Leak Test Acceptable Yes Adsorption Efficiency TA Luft Class III % Allowable Adsorption Efficiency % 95 Adsorption Efficiency Acceptable #REF! Temperature at Sample Tubes Temperature C 14 Allowable Temperature C 40 Temperature Acceptable Yes Test Conditions Ambient Temperature Recorded? Yes CATRT (Version BP) Page 38 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

39 TA LUFT CLASS III : QUALITY ASSURANCE (PAGE 2 OF 2) Blank Runs Leak Test Results Blank 1 Expected Sampling Rate l/min Sampling Leak Rate l/min Allowable Leak Rate l/min Leak Test Acceptable Yes Validity of Blank vs ELV Blank 1 Allowed Allowable for TA Luft Class III Allowable for TOTAL 1.4 ###### Method Deviations Nature of Deviation (x = deviation applies to the associated run) There are no deviations associated with the sampling employed. 1 x Run Number CATRT (Version BP) Page 39 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

40 TA LUFT CLASS III : MEASUREMENT UNCERTAINTY CALCULATIONS Value Measured Quantities Symbol Symbol Standard uncertainty Sampled Volume (STP) Leak Laboratory Result V m uv m m³ L ul % L r ul r % Measured Quantities Sampled Volume (STP) Leak Laboratory Result Uncertainty as a Percentage % 2.00 % 0.00 % Requirement of Standard 2% 5% No Requirement Measured Quantities Symbol Uncertainty in Measurement Sensitivity Coefficient Sampled Volume (STP) Leak Laboratory Result Measured Quantities Sampled Volume (STP) Leak Laboratory Result O₂ Correction Factor Stack Gas O₂ Content MU for O₂ Correction V m m³ L L r Measured Quantities Overall MU For O₂ Measurement 1.03 % v/v Uncertainty in Result Oxygen Correction Part of MU Budget % Combined uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty Expanded uncertainty (95% confidence), without Oxygen Correction Expanded uncertainty (95% confidence), with Oxygen Correction Expanded uncertainty (95% confidence), estimated with Method Deviations Reported Uncertainty NOTE: Uncertainties reported in mg/m ³ are based upon the summation of all Speciated VOCs Measured % 20.0 % 20.0 % 20.0 % 20.0 CATRT (Version BP) Page 40 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

41 OXIDES OF NITROGEN (as NO₂): RESULTS SUMMARY, Sample Runs Mean Concentration Uncertainty ± Mass Emission g/hr Uncertainty ±g/hr General Sampling Information Standard Technical Procedure Value EN CATTP21 Probe Material Stainless Steel Filtration Type / Size 0.1µm Glass Fibre Heated Head Filter Used Yes Heated Line Temperature 180 C Date & Result of Last Converter Check 15/04/ % Span Gas Type Nitrogen Monoxide Span Gas Reference Number CYL Span Gas Expiry Date 15/07/2019 Span Gas Start Pressure (bar) 20 Gas Cylinder Concentration (ppm) Span Gas Uncertainty (%) 2 Zero Gas Type Nitrogen (5 Grade) Number of Sampling Lines Used 1 / 1 Number of Sampling Points Used 1 / 1 NOTE: Dilution performed to achieve correct span value FORMAT: Number Used / Number Required FORMAT: Number Used / Number Required Sample Point I.D.'s A1 Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 41 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

42 OXIDES OF NITROGEN (as NO₂): DATA TREND Graphical Trend of Data Oxides of Nitrogen (as NO₂) At Reference Conditions COVER ME WITH CHART/S :20 13:22 13:24 13:26 13:28 13:30 13:32 13:34 13:36 13:38 13:40 13:42 13:44 13:46 13:48 13:50 13:52 13:54 13:56 13:58 14:00 14:02 14:04 14:06 14:08 14:10 14:12 14:14 14:16 14:18 Concentration () 14:20 CATRT (Version BP) Page 42 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

43 OXIDES OF NITROGEN (as NO₂): SAMPLING DETAILS & QUALITY ASSURANCE Sampling Details Sampling Times 13:20 14:20 Sampling Dates 18/10/2016 Instrument Range ppm 250 Span Gas Value ppm Quality Assurance Conditioning Unit Temperature Average Temperature C 2.2 Allowable Temperature < C 4.0 Temperature Acceptable Yes Zero Drift CAL 1 CAL 1 Zero Down Sampling Line (Pre) ppm 0.30 Zero Down Sampling Line (Post) ppm 2.70 Zero Drift ppm 2.40 Allowable Zero Drift ± ppm Zero Drift Acceptable #REF! Span Drift Span Down Sampling Line (Pre) ppm Span Down Sampling Line (Post) ppm Span Drift ppm 6.20 Allowable Span Drift ± ppm Span Drift Acceptable #REF! Test Conditions Run Ambient Temperature Range C Method Deviations Nature of Deviation (x = deviation applies to the associated run) There are no deviations associated with the sampling employed. Run Number 1 x CATRT (Version BP) Page 43 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

44 OXIDES OF NITROGEN (as NO₂): MEASUREMENT UNCERTAINTY CALCULATIONS Performance characteristics RUN 1 Limit value (REF) TGN M2 Allowable MU 10.0 % Measured concentration (STP, dry) Ration NO / NO₂ 10 % Range Used ppm Range Used [A] Cal gas conc ppm Conversion 2.05 ppm to MCERTS Range [B] Lower of [A] or [B] Cal gas conc Performance characteristics RUN 1 Response time 60 seconds Number of readings in measurement 60 Repeatability at zero 0.40 % full scale Repeatability at span level 0.40 % full scale Deviation from linearity 0.28 % of value Zero drift 0.99 % full scale Span drift 0.00 % full scale Volume or pressure flow dependence 0.40 % of full scale Atmospheric pressure dependence 0.30 % of value/kpa Ambient temperature dependence 0.18 % full scale/10k Combined interference Dependence on voltage % range % full scale/10v Converter efficiency 95.0 % Losses in the line (leak) 0.29 % of value Uncertainty of calibration gas blending 1.40 % of value Uncertainty of calibration gas 2.00 % of value Performance characteristic RUN 1 Standard deviation of repeatability at zero use rep at span Standard deviation of repeatability at span level 0.05 Lack of fit 0.20 Drift 2.85 Volume or pressure flow dependence 0.00 Atmospheric pressure dependence 0.11 Ambient temperature dependence 0.03 Combined interference (from MCERTS Certificate) 0.43 Dependence on voltage 0.05 Converter efficiency 0.91 Losses in the line (leak) 0.53 Uncertainty of calibration gas blending 2.56 Uncertainty of calibration gas 3.66 RUN 1 Measurement uncertainty Result Combined uncertainty 5.44 Expanded uncertainty k = Uncertainty corrected to std conds. (O₂) RUN 1 Expanded uncertainty (no O₂) at 95% Confidence 3.37 % of Value Expanded uncertainty (no O₂) at 95% Confidence 2.13 % at ELV Overall Allowable uncertainty (no O₂) at 95% Confidence 10.0 % at ELV Result of Compliance with Uncertainty Requirement in M2 N/A RUN 1 Expanded uncertainty (with O₂) at 95% Confidence 6.07 % of Value Expanded uncertainty (with O₂) at 95% Confidence 5.51 % at ELV Overall Allowable uncertainty (with O₂) at 95% Confidence 11.2 % at ELV Result of Compliance with Uncertainty Requirement in M2 COMPLIANT (REF) Requirement for SRM is that Uncertainty should be <10% of the value at the ELV, on a dry gas basis, or if O₂ correction is applied less than 10% + the uncertainty associated with the O₂ correction (using sqrt of sum squares to add uncertainty components). Ref EA TGN M2. CATRT (Version BP) Page 44 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

45 CARBON MONOXIDE: RESULTS SUMMARY, Sample Runs Mean Concentration Uncertainty ± Mass Emission Uncertainty g/hr ±g/hr General Sampling Information Value Standard EN Technical Procedure CATTP21 Probe Material Stainless Steel Filtration Type / Size 0.1µm Glass Fibre Heated Head Filter Used Yes Heated Line Temperature 180 C Span Gas Type Span Gas Reference Number CYL Span Gas Expiry Date Carbon Monoxide 19/04/2019 Span Gas Start Pressure (bar) 40 Gas Cylinder Concentration (ppm) Span Gas Uncertainty (%) NOTE: Dilution performed to achieve correct span value Zero Gas Type Nitrogen (5 Grade) Number of Sampling Lines Used Number of Sampling Points Used 1 / 1 1 / 1 FORMAT: Number Used / Number Required FORMAT: Number Used / Number Required Sample Point I.D.'s A1 Reference Conditions Reference Conditions are: 273K, 101.3kPa, dry gas, 5% oxygen. CATRT (Version BP) Page 45 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

46 CARBON MONOXIDE: DATA TREND Graphical Trend of Data Carbon Monoxide COVER ME WITH CHART/S At Reference Conditions :20 13:22 13:24 13:26 13:28 13:30 13:32 13:34 13:36 13:38 13:40 13:42 13:44 13:46 13:48 13:50 13:52 13:54 13:56 13:58 14:00 14:02 14:04 14:06 14:08 14:10 14:12 14:14 14:16 14:18 Concentration () 14:20 CATRT (Version BP) Page 46 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

47 CARBON MONOXIDE: SAMPLING DETAILS & QUALITY ASSURANCE Sampling Details Sampling Times 13:20 14:20 Sampling Dates 18/10/2016 Instrument Range ppm 500 Span Gas Value ppm Quality Assurance Conditioning Unit Temperature Average Temperature C 2.2 Allowable Temperature < C 4.0 Temperature Acceptable Yes Zero Drift CAL 1 CAL 1 Zero Down Sampling Line (Pre) ppm 1.10 Zero Down Sampling Line (Post) ppm 2.60 Zero Drift ppm 3.70 Allowable Zero Drift ± ppm Zero Drift Acceptable Span Drift Span Down Sampling Line (Pre) Span Down Sampling Line (Post) Span Drift Allowable Span Drift Span Drift Acceptable #REF! ppm ppm ppm 1.10 ± ppm #REF! Test Conditions Run Ambient Temperature Range C Method Deviations Nature of Deviation (x = deviation applies to the associated run) There are no deviations associated with the sampling employed. Run Number 1 x CATRT (Version BP) Page 47 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

48 CARBON MONOXIDE: MEASUREMENT UNCERTAINTY CALCULATIONS Performance characteristics RUN 1 Limit value (REF) TGN M2 Allowable MU 6.0 % Measured concentration (STP, dry) Range Used ppm Range Used [A] Cal gas conc ppm Conversion 1.25 ppm to MCERTS Range [B] 95.0 Lower of [A] or [B] 95.0 Cal gas conc Performance characteristics RUN 1 Response time 60 seconds Number of readings in measurement 60 Repeatability at zero 0.40 % full scale Repeatability at span level 0.40 % full scale Deviation from linearity 0.37 % of value Zero drift 0.91 % full scale Span drift 0.27 % full scale Volume or pressure flow dependence 0.40 % of full scale Atmospheric pressure dependence 0.30 % of value/kpa Ambient temperature dependence 0.05 % full scale/10k Combined interference 0.73 % range Dependence on voltage 0.40 % full scale/10v Losses in the line (leak) 0.15 % of value Uncertainty of calibration gas blending 1.40 % of value Uncertainty of calibration gas 2.00 % of value Performance characteristic RUN 1 Standard deviation of repeatability at zero use rep at span Standard deviation of repeatability at span level 0.05 Lack of fit 0.20 Drift 1.77 Volume or pressure flow dependence 0.00 Atmospheric pressure dependence 0.08 Ambient temperature dependence 0.01 Combined interference (from MCERTS Certificate) 0.40 Dependence on voltage 0.05 Losses in the line (leak) 0.49 Uncertainty of calibration gas blending 4.65 Uncertainty of calibration gas 6.64 RUN 1 Measurement uncertainty Result Combined uncertainty 8.33 Expanded uncertainty k = Uncertainty corrected to std conds. (O₂) (REF) RUN 1 Expanded uncertainty (no O₂) at 95% Confidence 2.84 % of Value Expanded uncertainty (no O₂) at 95% Confidence 1.17 % at ELV Overall Allowable uncertainty (no O₂) at 95% Confidence 6.0 % at ELV Result of Compliance with Uncertainty Requirement in M2 N/A RUN 1 Expanded uncertainty (with O₂) at 95% Confidence 5.80 % of Value Expanded uncertainty (with O₂) at 95% Confidence 5.19 % at ELV Overall Allowable uncertainty (with O₂) at 95% Confidence 7.8 % at ELV Result of Compliance with Uncertainty Requirement in M2 COMPLIANT Requirement for SRM is that Uncertainty should be <6% of the value at the ELV, on a dry gas basis, or if O₂ correction is applied less than 6% + the uncertainty associated with the O₂ correction (using sqrt of sum squares to add uncertainty components). Ref EA TGN M2. CATRT (Version BP) Page 48 of 52 Job Number: CEK2280, Version 2 EPA Export :14:57:12 Industrial Emissions Licence: W000903

For inspection purposes only.

For inspection purposes only. ISO/IEC 17025 Accredited Legal Entity, UKAS Accredited Testing Laboratory No. 4279 Exova (UK) Ltd trading as Exova Catalyst & Exova Catalyst Ireland Unit C5, Emery Court, The Embankment Business Park,

More information

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report. Site Visit Report The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where noncompliance against a particular condition has not

More information

For inspection purposes only.

For inspection purposes only. ISO/IEC 17025 Accredited Legal Entity, UKAS Accredited Testing Laboratory No. 4279 Exova (UK) Ltd trading as Exova Catalyst & Exova Catalyst Ireland Unit C5, Emery Court, The Embankment Business Park,

More information

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report. Site Visit Report The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where noncompliance against a particular condition has not

More information

Document No.: NOKETL / IPPC Licence No.: W

Document No.: NOKETL / IPPC Licence No.: W Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person Air Emissions Compliance Monitoring Emissions Report Air Scientific Ltd., 32 DeGranville Court,

More information

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report. Site Visit Report The site visit process is a sample on a particular day of an installation's compliance with some of its licence conditions. Where noncompliance against a particular condition has not

More information

Facility Location: Castlefarm Centre and Clonmel Rd, Mitchelstown, Co. Cork Office: Trim Rev.No: 1

Facility Location: Castlefarm Centre and Clonmel Rd, Mitchelstown, Co. Cork Office: Trim Rev.No: 1 Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person EPA Licence Number Licence Holder Stack Reference Number Air Emissions Compliance Monitoring Emissions

More information

Office: Trim Rev.No: 1

Office: Trim Rev.No: 1 Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person EPA Licence Number Licence Holder Stack Reference Number Air Emissions Compliance Monitoring Emissions

More information

Facility Location: Rilta Environmental Limited, Block 402, Grant's Drive, Dublin. Office: Trim Rev.No: 1. For inspection purposes only.

Facility Location: Rilta Environmental Limited, Block 402, Grant's Drive, Dublin. Office: Trim Rev.No: 1. For inspection purposes only. Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person EPA Licence Number Licence Holder Stack Reference Number Air Emissions Compliance Monitoring Emissions

More information

STACK EMISSIONS MONITORING REPORT

STACK EMISSIONS MONITORING REPORT STACK EMISSIONS MONITORING REPORT 24 Langlands Place Kelvin South Business Park East Kilbride G75 0YF Tel: 01355 246 730 Fax: 01355 249 669 Your contact at David Hay Business Manager North Tel: 01355 246

More information

AIR & EMISSIONS TESTING GROUP

AIR & EMISSIONS TESTING GROUP AIR & EMISSIONS TESTING GROUP 52 Offerton Industrial Estate Hempshaw Lane Stockport SK2 5TJ Tel: 0161 477 3004 Fax: 0161 480 4642 Your contact at Environmental Scientifics Group: Andrew Palliser Business

More information

Unit 11, Aspen Close, Swindon, SN2 8AJ T: E: Your Catalyst Contact: Stuart Davidson ( )

Unit 11, Aspen Close, Swindon, SN2 8AJ T: E: Your Catalyst Contact: Stuart Davidson ( ) Unit 11, Aspen Close, Swindon, SN2 8AJ T: 0800 328 1821 E: stuart.davidson@catenv.com Your Catalyst Contact: Stuart Davidson (07957 554 956) Stack Emissions Testing Report Commissioned by Installation

More information

Facility Location: Smithstown Facility Office: Trim Rev.No: 1. For inspection purposes only.

Facility Location: Smithstown Facility Office: Trim Rev.No: 1. For inspection purposes only. Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person EPA Licence Number Licence Holder Stack Reference Number Air Emissions Compliance Monitoring Emissions

More information

Facility Location: Smithstown Facility Office: Trim Rev.No: 1. For inspection purposes only.

Facility Location: Smithstown Facility Office: Trim Rev.No: 1. For inspection purposes only. Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person EPA Licence Number Licence Holder Stack Reference Number Air Emissions Compliance Monitoring Emissions

More information

Document No.: HAMETL / IPPC Licence No.: P

Document No.: HAMETL / IPPC Licence No.: P Report Title Company address Stack Emissions Testing Report Commissioned by Facility Name Contact Person Air Emissions Compliance Monitoring Emissions Report Air Scientific Ltd., 32 DeGranville Court,

More information

STACK EMISSIONS MONITORING REPORT

STACK EMISSIONS MONITORING REPORT STACK EMISSIONS MONITORING REPORT 24 Langlands Place Kelvin South Business Park East Kilbride G75 0YF Tel: 01355 246 730 Fax: 01355 249 669 Your contact at ESG David Hay Business Manager North Tel: 01355

More information

Air Dispersion Modelling Report

Air Dispersion Modelling Report Air Dispersion Modelling Report Johnson & Johnson Vision Care (Ireland) Industrial Emissions Licence Review IE0311829-22-RP-0002, Issue: A Issue date: 09 March 2016 Document Sign Off Air Dispersion Modelling

More information

For inspection purposes only.

For inspection purposes only. Unit 5 Caherdavin Business Centre Ennis Road Limerick Ireland +353 61 324587 Tel www.axisenv.ie Patrick Doyle, Administration Officer, Office of Climate, Licensing & Resource Use, Regional Inspectorate,

More information

Emissions Testing Report 2014

Emissions Testing Report 2014 Orora Limited 09-Apr-2014 Emissions Testing Report 2014 Orora Limited NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 This document is issued in accordance with NATA s

More information

Emissions Testing Report 2015

Emissions Testing Report 2015 Orora Limited 20-Jul-2015 Emissions Testing Report 2015 Orora Limited NATA ACCREDITATION No. 2778 (14391) Accredited for compliance with ISO/IEC 17025 This document is issued in accordance with NATA s

More information

Test Report TR1R1

Test Report TR1R1 1 CLIENT DETAILS Organisation: Company Contact: Origin Energy Services Ltd Eoghain Maguire Site Address: 101-103 Miller Street, North Sydney NSW 2060 Postal Address: Level 7, 321 Exhibition Street, Melbourne

More information

I of 23. Consent of copyright owner required for any other use. For inspection purposes only.

I of 23. Consent of copyright owner required for any other use. For inspection purposes only. Document No.: UCIRTL1260116 12016031 Industrial Emissions Licence No.: POO20-02 Wsit No: 1, Shannon, Co. Clare Sampling Line A I Point 1 Distance to duct (m) I Pa I Temp C I Velocity(m/s) 1 Oxygen (%)

More information

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW

National Physical Laboratory Hampton Road Teddington Middlesex United Kingdom TW11 0LW NPL REPORT AS 26 Validation of an Alternative Method for the measurement of SO 2 emissions using instrumental methods Rod Robinson, Marc Coleman, Matthew Williams, Robert Elliott, Martin Clack, Andrew

More information

Test Report TR1R0

Test Report TR1R0 1 CLIENT DETAILS Organisation: Company Contact: Cogent Energy Pty Ltd Eoghain Maguire Site Address: 101-103 Miller Street, North Sydney NSW 2060 Postal Address: Suite 2, Level 9, 1 Chandos Street, St Leonards

More information

EPA vs. EN standards

EPA vs. EN standards EPA vs. EN standards 1 Tasks Goal: Determination of differences and similarities of EN and EPA to get a guideline what to change to be consistent within the EN CEMS framework Text comparison Approx. 1

More information

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5938/S24635/18 DATE OF SURVEY: 12 MARCH 2018

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5938/S24635/18 DATE OF SURVEY: 12 MARCH 2018 Stephenson Environmental Management Australia CO-GENERATION PLANT STACK EMISSION TESTING - 2018 TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5938/S24635/18 DATE OF SURVEY: 12 MARCH 2018 DATE OF ISSUE: 29

More information

Method Implementation Document (MID 1948)

Method Implementation Document (MID 1948) Method Implementation Document (MID 1948) BS EN 1948 Parts 1-3: 2006 Stationary source emissions - Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs Part 1: Sampling of PCDDs/PCDFs

More information

Emissions Testing Report

Emissions Testing Report National Ceramic Industries Australia 05-May-2014 60305580 Commercial-in-Confidence Emissions Testing Report 2013-14 National Ceramic Industries Australia NATA ACCREDITATION No. 2778 (14391) Accredited

More information

15 of 23. Consent of copyright owner required for any other use. For inspection purposes only. Sampling Line A Point. Distance to duct (m) I Pa Temp C

15 of 23. Consent of copyright owner required for any other use. For inspection purposes only. Sampling Line A Point. Distance to duct (m) I Pa Temp C Sampling Line A Point Distance to duct (m) I Pa Temp C 15 of 23 Document No.: UCIRTL1260116 /2016031 Year: 201 6 Industrial Emissions Licence No.: POO20-02 Facility Location: UCB Manufacturing Ireland

More information

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5648/S24184/16 DATE OF SURVEY: 24 MARCH 2016

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5648/S24184/16 DATE OF SURVEY: 24 MARCH 2016 Stephenson Environmental Management Australia CO-GENERATION PLANT STACK EMISSION TESTING - 2016 TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5648/S24184/16 DATE OF SURVEY: 24 MARCH 2016 DATE OF ISSUE: 21

More information

Assured Monitoring Group

Assured Monitoring Group ABN: 87 604 851 078 Assured Monitoring Group SOURCE EMISSIONS MONITORING BORAL WYEE BORAL ROOFING NSW Project ID. 10986 R_0 DATE OF RELEASE: 24/08/2017 Unit 7, 142 Tennyson Memorial Avenue Tennyson Queensland

More information

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5522/S23794/15 DATE OF SURVEY: 15 JULY 2015

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5522/S23794/15 DATE OF SURVEY: 15 JULY 2015 Stephenson Environmental Management Australia CO-GENERATION PLANT STACK EMISSION TESTING TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5522/S23794/15 DATE OF SURVEY: 15 JULY 2015 DATE OF ISSUE: 31 JULY 2015

More information

Method Implementation Document for BS EN * - Application to manual stack emissions monitoring

Method Implementation Document for BS EN * - Application to manual stack emissions monitoring Method Implementation Document for BS EN 16911-1* - Application to manual stack emissions monitoring *BS EN ISO 16911-1:2013 Stationary source emissions - Manual and automatic determination of velocity

More information

ENVIRONMENTAL MONITORING OF EMISSIONS FROM PAINT MANUFACTURING PROCESS

ENVIRONMENTAL MONITORING OF EMISSIONS FROM PAINT MANUFACTURING PROCESS ODOUR & ENVIRONMENTAL ENGINEERING CONSULTANTS Unit 32 De Granville Court, Dublin Rd, Trim, Co. Meath Tel: +353 46 9437922 Mobile: +353 86 8550401 E-mail: info@odourireland.com www.odourireland.com ENVIRONMENTAL

More information

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Technical Guidance Note (Monitoring) M5 Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions Environment Agency XXXX 2018 Version X Draft for consultation Foreword

More information

3rd Quarter Emissions Testing Report 2018

3rd Quarter Emissions Testing Report 2018 OneSteel 3rd Quarter Recycling Emissions Pty Testing Ltd Report 2018 Commercial-in-Confidence Doc Commercial-in-Confidence No. 60493017_3.1_Q3_2018 60493017 3rd Quarter Emissions Testing Report 2018 OneSteel

More information

2nd Quarter Emissions Testing Report 2013

2nd Quarter Emissions Testing Report 2013 OneSteel Recycling Pty Ltd 17-Jul-2013 60290660 Commercial-in-Confidence 2nd Quarter Emissions Testing Report 2013 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance

More information

AMBIENT DUST MONITORING REPORT

AMBIENT DUST MONITORING REPORT AMBIENT DUST MONITORING REPORT 2-4 Langlands Place Kelvin South Business Park East Kilbride G75 0YF Tel: 01355 246 730 Fax: 01355 249 669 Your contact at ESG David Hay Business Manager - North Tel: 01355

More information

Emissions Monitoring: Talinga GPF

Emissions Monitoring: Talinga GPF Emissions Monitoring: Talinga GPF Origin Energy 144 Montague Road West End QLD, 4101 November 2015 Issued: 9 November 2015 Prepared by: Air Noise Environment ABN: 13 081 834 513 This document is issued

More information

2nd Quarter Emissions Testing Report 2017

2nd Quarter Emissions Testing Report 2017 OneSteel 2nd Quarter Recycling Emissions Pty Testing Ltd Report 2017 20-Jun-2017 Doc No. 60493017_2.1_Q2_2017 2nd Quarter Emissions Testing Report 2017 OneSteel Recycling Hexham NATA ACCREDITATION No.

More information

4th Quarter Emissions Testing Report 2016

4th Quarter Emissions Testing Report 2016 4th Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.1_Q4_2016 4th Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391)

More information

2nd Quarter Emissions Testing Report 2016

2nd Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.2_Q2_2016 Commercial-in-Confidence 2nd Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance

More information

4th Quarter Emissions Testing Report 2015

4th Quarter Emissions Testing Report 2015 OneSteel Recycling Pty Ltd Doc No. 60290660_3.1_Q4 Commercial-in-Confidence 4th Quarter Emissions Testing Report 2015 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance

More information

3rd Quarter Emissions Testing Report 2016

3rd Quarter Emissions Testing Report 2016 3rd Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.1_Q3_2016 3rd Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391)

More information

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS

DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS MS 1596: 2003 DETERMINATION OF CONCENTRATION AND MASS FLOW OF PARTICULATE MATTER IN FLUE GAS FOR STATIONARY SOURCE EMISSIONS Presented BY: UiTM A&A Laboratory Malaysia s 1 st University Affiliated Environmental

More information

Metro Vancouver Metrotower III 4730 Kingsway Burnaby, BC V5H 0C6

Metro Vancouver Metrotower III 4730 Kingsway Burnaby, BC V5H 0C6 METRO VANCOUVER WASTE-TO-ENERGY FACILITY COMPLIANCE TESTING REPORT November 2017 Emission Survey Prepared For: Metro Vancouver Metrotower III 4730 Kingsway Burnaby, BC V5H 0C6 Prepared by: A. Lanfranco

More information

EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER NSPS TEST METHOD. Method 10 - Determination of Carbon Monoxide Emissions from Stationary Sources

EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER NSPS TEST METHOD. Method 10 - Determination of Carbon Monoxide Emissions from Stationary Sources EMISSION MEASUREMENT TECHNICAL INFORMATION CENTER NSPS TEST METHOD Method 10 - Determination of Carbon Monoxide Emissions from Stationary Sources 1. PRINCIPLE AND APPLICABILITY 1.1 Principle. An integrated

More information

Training for Personnel to the MCERTS standard Level 1 Technician and Level 2- Team Leader. Syllabus

Training for Personnel to the MCERTS standard Level 1 Technician and Level 2- Team Leader. Syllabus This course is designed to provide training for personnel that are at trainee level and wish to progress through to Level 1 and then progress to Level 2. The course duration is based on five days. Who

More information

Particulate Emission Monitor Spot Correlations. Camden Power Station Stacks 1, 2 & 3 May 2011 RPHP147

Particulate Emission Monitor Spot Correlations. Camden Power Station Stacks 1, 2 & 3 May 2011 RPHP147 Particulate Emission Monitor Spot Correlations Camden Power Station Stacks 1, 2 & 3 May 2011 P.O. Box 2459 Noordheuwel ext 4 Krugersdorp 1756 Vat No. 4670254459 STACKLABS ENVIRONMENTAL SERVICES 10 Chisel

More information

Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring

Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring Guidance for Portable Electrochemical Analyzer Testing Used for Compliance Monitoring Section I. Introduction DEQ s Air Quality Division administers the provisions of 40 CFR Part 70 as well as the minor

More information

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators Technical Guidance Note (Monitoring) M5 Monitoring of stack gas emissions from medium combustion plants and specified generators Environment Agency September 2018 Draft Version Foreword This technical

More information

PRODUCT CONFORMITY CERTIFICATE This is to certify that the

PRODUCT CONFORMITY CERTIFICATE This is to certify that the PRODUCT CONFORMITY CERTIFICATE This is to certify that the Babcock & Wilcox Model 2008-1 CEMS (EN 15267-3 Standard) & Babcock & Wilcox Stack Flow Monitor Model 110 manufactured by: Babcock & Wilcox Company

More information

EXAMPLE CALCULATIONS ASSOCIATED WITH THE MEASURMENT OF PHASE PARTITIONED SPECIES

EXAMPLE CALCULATIONS ASSOCIATED WITH THE MEASURMENT OF PHASE PARTITIONED SPECIES Note: the following are examples of the type of calculations you may be asked to perform in the TE2 narrative paper. This is not a complete exam paper. Calculation questions typically make up 20 out of

More information

METHOD 4 - DETERMINATION OF MOISTURE CONTENT IN STACK GASES. NOTE: This method does not include all the

METHOD 4 - DETERMINATION OF MOISTURE CONTENT IN STACK GASES. NOTE: This method does not include all the 347 METHOD 4 - DETERMINATION OF MOISTURE CONTENT IN STACK GASES NOTE: This method does not include all the specifications (e.g., equipment and supplies) and procedures (e.g., sampling) essential to its

More information

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the 1035 METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g.,

More information

Emission Testing August 2013 EPA 4 Benzene Combustor Inlet/Outlet Testing

Emission Testing August 2013 EPA 4 Benzene Combustor Inlet/Outlet Testing Page: 1 of 12 Gate 38B, 45 Friendship Rd Port Botany NSW 2036 Dear Mr G Millard, August 2013 EPA 4 Benzene Combustor Inlet/Outlet Testing Tests were performed 10th August 2013 to determine emissions from

More information

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682 Source Test Guidance Test plans are required to be submitted to SWCAA prior to testing. Generally the plans must be submitted 2 weeks prior to testing but may be different based on individual facility

More information

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING - ANNUAL, 2014 TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5449/S23558/14

Stephenson CO-GENERATION PLANT STACK EMISSION TESTING - ANNUAL, 2014 TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5449/S23558/14 Stephenson Environmental Management Australia CO-GENERATION PLANT STACK EMISSION TESTING - ANNUAL, 2014 TOOHEYS PTY LTD LIDCOMBE, NSW PROJECT NO.: 5449/S23558/14 DATE OF SURVEY: 4 DECEMBER 2014 DATE OF

More information

Bord Na Móna Environmental Ltd trading as ANUA

Bord Na Móna Environmental Ltd trading as ANUA trading as ANUA Technical Services Analytical Laboratory, Main Street, Newbridge, Co. Kildare Testing Laboratory Registration number: 083T is accredited by the Irish National Board (INAB) to undertake

More information

Automatic Isokinetic Sampler ST5

Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Automatic Isokinetic Sampler ST5 Description The ST5 is the next generation isokinetic sampler, developed to be efficient, rugged, accurate and user friendly. The perfect

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT NFORMITY CERTIFICATE This is to certify that the PG-250 Portable Gas Analyser Pre-conditioner PS200 manufactured by: Horiba Limited Miyanohigashi Kisshoin Minami-Ku Kyoto Japan has been assessed

More information

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic Stack Sampling emissions associated with combustion, velocity and temperature may be much higher than ambient conditions - measure to correct to standard conditions Velocity data determined from pressure

More information

GENERAL TESTING AND REPORTING REQUIREMENTS

GENERAL TESTING AND REPORTING REQUIREMENTS GENERAL TESTING AND REPORTING REQUIREMENTS Ohio EPA requires that an Ohio Intent to Test ( ITT ) form be filed with the appropriate Ohio EPA representative at least 30 days (or more if required by regulation)

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Laboratory locations: Schedule of ccreditation 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit H7 Washington usiness Centre Turbine usiness Park Turbine Way Washington Tyne & Wear SR5

More information

Fpollutant-free zero air for analytical

Fpollutant-free zero air for analytical Ambient Air Quality Monitoring System AQMS-100 Zero Air Generator PI AQMS-100 provides ultra pure Fpollutant-free zero air for analytical purpose. Remote monitoring and configuration can also be achieved

More information

Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites

Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites 1. OVERVIEW In Ireland at present industrial air emissions monitoring at licensed/permitted sites is required to be carried out by ISO17025

More information

EMIOTEST 3114 Gravimetric dust meter set

EMIOTEST 3114 Gravimetric dust meter set Technical card EMIOTEST 3114 Gravimetric dust meter set 1. Purpose and scope of application Automatic dust meter EMIOTEST 3114, in its innovative technical solution, is a portable device designed to perform,

More information

t-- L 1.2 i L +g/hr 0.8 talyst Consent of copyright owner required for any other use. For inspection purposes only. TOTAL AMINES : RESULTS SUMMARY

t-- L 1.2 i L +g/hr 0.8 talyst Consent of copyright owner required for any other use. For inspection purposes only. TOTAL AMINES : RESULTS SUMMARY ~ talyst TOTAL AMINES : RESULTS SUMMARY, Bio Scrubber (Inlet) Sample Runs Units Run 2 /Uncertainty +rng/m 0.1 t-- P Uncertainty i L +g/hr 0.8 L 1.2 NOTE Where the maximum Blank concentration is higher

More information

Stephenson ANNUAL EMISSION SURVEY SCRUBBER STACK (EPA ID 2) BITUMINOUS PRODUCTS PTY LTD REVESBY, NSW PROJECT NO.

Stephenson ANNUAL EMISSION SURVEY SCRUBBER STACK (EPA ID 2) BITUMINOUS PRODUCTS PTY LTD REVESBY, NSW PROJECT NO. Stephenson Environmental Management Australia ANNUAL EMISSION SURVEY 2018 - SCRUBBER STACK (EPA ID 2) REVESBY, NSW PROJECT NO.: 5997/S/S25146/18 DATE OF SURVEY: 11 SEPTEMBER 2018 DATE OF ISSUE: 2 OCTOBER

More information

Kendal Power Station Units No. 2 & 6 Particulate Emission Monitor Correlations. 30th September 2016 Report No. RSL224

Kendal Power Station Units No. 2 & 6 Particulate Emission Monitor Correlations. 30th September 2016 Report No. RSL224 Kendal Power Station Units No. 2 & 6 Particulate Emission Monitor Correlations 30th September 2016 Report No. RSL224 P.O. Box 2459 Noordheuwel ext 4 Krugersdorp 1756 Vat No. 4670254459 10 Chisel Street

More information

Emission Testing June 2014 Ingal Civil Products Minto Plant

Emission Testing June 2014 Ingal Civil Products Minto Plant Page: 1 of 8 57-65 Airds Rd MINTO NSW 2566 June 2014 Minto Plant Dear Amit, Tests were performed 17 June 2014 to determine emissions to air from 2 locations at the Minto plant of. LICENCE COMPARISON...

More information

METHOD BERYLLIUM SCREENING METHOD. Analyte CAS No. Sensitivity Beryllium (Be) Dependent upon analytical procedure used

METHOD BERYLLIUM SCREENING METHOD. Analyte CAS No. Sensitivity Beryllium (Be) Dependent upon analytical procedure used 1764 METHOD 103 - BERYLLIUM SCREENING METHOD 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Beryllium (Be) 7440-41-7 Dependent upon analytical procedure used 1.2 Applicability. This

More information

Chapter 15. Air Monitoring. Source Sampling

Chapter 15. Air Monitoring. Source Sampling Chapter 5 Air Monitoring Source Sampling A representative sample is the key to the accurate measurement of emissions from a source. Different source test methods have been developed for a variety of realistic

More information

Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section

Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section Alabama Department of Environmental Management Air Division Planning Branch Emission Measurement Section Particulate Sampling Guideline & Reporting Format Revision No. 6 December 2003 PARTICULATE SAMPLING

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 13199 First edition 2012-10-15 Stationary source emissions Determination of total volatile organic compounds (TVOCs) in waste gases from non-combustion processes Nondispersive

More information

Comparison Continuous Emission Monitoring Techniques

Comparison Continuous Emission Monitoring Techniques PRODUCT DATASHEET: Comparison Continuous Comparison Continuous Emission Monitoring Techniques Overview The requirements for continuous emission monitors has changed significantly over the last 30 years.

More information

INTHUU MEASUREMENTS CC

INTHUU MEASUREMENTS CC INTHUU MEASUREMENTS CC VAT REG NO.: 4960254359 REG NO.: 2009/190265/23 P.O. Box 14769 Bredell, 1623 Plot 2/410 Seventh Road Bredell A/H, Kempton Park, 1619 Tel: +27 (0)82 572-2380 Fax: +27 (0)86 659-2231

More information

CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS

CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS Jurij ČRETNIK RACI d.o.o., Tehnološki park 24, SI-1000 LJUBLJANA, SLOVENIA jurij.cretnik@raci.si Matjaž ŠLIBAR RACI d.o.o., Tehnološki park 24,

More information

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the

METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT. NOTE: This method does not include all of the 312 METHOD 3 - GAS ANALYSIS FOR THE DETERMINATION OF DRY MOLECULAR WEIGHT NOTE: This method does not include all of the specifications (e.g., equipment and supplies) and procedures (e.g., sampling) essential

More information

Problems with Pitots. Issues with flow measurement in stacks.

Problems with Pitots. Issues with flow measurement in stacks. CEM-2004 Problems with Pitots. Issues with flow measurement in stacks. R A Robinson 1, D Butterfield 1, D Curtis 2, T Thompson 3 1 National Physical Laboratory Queens Road Teddington Middlesex TW11 0AX

More information

CO Sensor Response Study NO & NOx Analyzer Validation. June 6, 2018

CO Sensor Response Study NO & NOx Analyzer Validation. June 6, 2018 CO Sensor Response Study NO & NOx Analyzer Validation June 6, 2018 HOW TO MEASURE MULTIPLE ZONES Sensor Options Available Passive sensors Small and easy to use Rely on diffusion to reach sensor Vacuum

More information

Assured Monitoring Group

Assured Monitoring Group SOURCE EMISSIONS MONITORING KYOGLE TIMBER PLANT Assured Monitoring Group BORAL TIMBER Project ID. 11141 R_0 DATE OF RELEASE: 29/11/2017 ABN: 87 604 851 078 Unit 7, 142 Tennyson Memorial Avenue Tennyson

More information

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: SOLUTION 2.

TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: SOLUTION 2. TEST REPORT SCOPE: EMISSIONS, EFFICIENCY AND OUTPUT FUEL: EPA TEST FUEL (CRIBS) TEST STANDARD: EPA MODEL: SOLUTION 2.3-I WOOD INSERT Notice to reader: Our Solution 2.3-I wood insert was tested as part

More information

WASTE TO ENERGY FACILITY Emissions Testing Report February st Quarter Survey Operational Certificate Prepared for METRO VANCOUVER

WASTE TO ENERGY FACILITY Emissions Testing Report February st Quarter Survey Operational Certificate Prepared for METRO VANCOUVER Prepared for METRO VANCOUVER Metrotower III 4730 Kingsway Burnaby, BC V5H 0C6 WASTE TO ENERGY FACILITY Emissions Testing Report February 2019 1st Quarter Survey Operational Certificate 107051 CERTIFICATION

More information

The development of instrumentation for application to carbon capture and storage measurements

The development of instrumentation for application to carbon capture and storage measurements The development of instrumentation for application to carbon capture and storage measurements Nicholas A Martin National Physical Laboratory (NPL), Analytical Science Division, Environmental Measurements

More information

Development of tar sampling system

Development of tar sampling system Development of tar sampling system - 1 - 1. Tar sampling according to CEN/TS 15439:2006 Installation The installation should be as shown in the figure. There is a pipe in the flange in case the sample

More information

Performance Standards for Continuous Ambient Air Quality Monitoring Systems. Environment Agency Version 8 June 2012

Performance Standards for Continuous Ambient Air Quality Monitoring Systems. Environment Agency Version 8 June 2012 Performance Standards for Continuous Ambient Air Quality Monitoring Systems Environment Agency Version 8 June 2012 Foreword We set up our Monitoring Certification Scheme (MCERTS) to provide a framework

More information

TEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562

TEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562 TEST REPORT REPORT NUMBER: 102741836MID-001bR2 REPORT DATE: October 24, 2016 REVISED REPORT DATE: August 7, 2017 REVISED REPORT DATE: August 11, 2017 REVISED REPORT DATE: September 6, 2017 EVALUATION CENTER

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the PG-350E Multi-component Gas Analyser Manufactured by: Horiba Europe GmbH Julius Kronenberg Straße 9 42799 Leichlingen Germany Has been assessed

More information

TEST REPORT. REPORT NUMBER: MID-001b REPORT DATE: November 10, 2016

TEST REPORT. REPORT NUMBER: MID-001b REPORT DATE: November 10, 2016 TEST REPORT REPORT NUMBER: 102527563MID-001b REPORT DATE: November 10, 2016 EVALUATION CENTER Intertek Testing Services NA Inc. 8431 Murphy Drive Middleton, WI 53562 RENDERED TO HY-C Company, LLC 10950

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the PG 250 SRM Portable Gas Analyser manufactured by: Horiba Europe GmbH Julius Kronenberg Straße 9 42799 Leichlingen Germany has been assessed by

More information

ABSTRACT INTRODUCTION

ABSTRACT INTRODUCTION Simultaneous PM10 And PM2.5 Measurement From Stacks According to New ISO 23210 Standard Erkki J. Lamminen Dekati Ltd. Osuusmyllynkatu 13, 33700 Tampere, Finland ABSTRACT A new ISO standard 23210 for simultaneous

More information

An Overview of Mercury Monitoring Options

An Overview of Mercury Monitoring Options An Overview of Mercury Monitoring Options David Graham, Uniper Technologies Ltd. CRF 27 th Annual Meeting, Imperial College, London, 20 April 2016 Introduction What do we need to measure? Total mercury

More information

HORIBA Portable Emissions Measurement Systems (PEMS)

HORIBA Portable Emissions Measurement Systems (PEMS) HORIBA Portable Emissions Measurement Systems (PEMS) PEMS for Light Duty Vehicle Workshop DAIMLER Stuttgart September 2011 C 2011 HORIBA, Ltd. All rights reserved. Introduction PEMS for Gaseous Measurements

More information

Fully Extractive Vs. Dilution Extractive CEMS

Fully Extractive Vs. Dilution Extractive CEMS Fully Extractive Vs. Dilution Extractive CEMS Cemtek Environmental Emissions Seminar & Training Session Santa Ana, CA a technical solution to meet every need CEMTEK Environmental Inc. 3041 S. Orange Ave.

More information

Dall Energy Biomass Furnace

Dall Energy Biomass Furnace Dall Energy Biomass Furnace Test Plan Low particle, CO and NO x emission furnace Maj 2011 Project Manager: Marianne Kyed Ørbæk 1. TABLE OF CONTENTS 1. TABLE OF CONTENTS... 2 2. INTRODUCTION... 4 2.1. VERIFICATION

More information

Kerry Ingredients (Ireland) Ltd. Attachments to Objection No 8 of Appeal to Draft IPPCL No Schedule B: B.1 Emissions to Air

Kerry Ingredients (Ireland) Ltd. Attachments to Objection No 8 of Appeal to Draft IPPCL No Schedule B: B.1 Emissions to Air Attachments to Objection No 8 of Appeal to Draft PPCL No. 749 Kerry ngredients Ltd: Appeal of PPC Licence No 749 Schedule B: B.1 Emissions to Air Bl.1 Bailer Emissions Submission by Envirocon Ltd relating

More information

METHOD 5A - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM THE ASPHALT PROCESSING AND ASPHALT ROOFING INDUSTRY

METHOD 5A - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM THE ASPHALT PROCESSING AND ASPHALT ROOFING INDUSTRY 446 METHOD 5A - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM THE ASPHALT PROCESSING AND ASPHALT ROOFING INDUSTRY NOTE: This method does not include all of the specifications (e.g., equipment and

More information

Heated FID OVF Portable THC/TVOC Analyzer

Heated FID OVF Portable THC/TVOC Analyzer Heated FID OVF-3000 Portable THC/TVOC Analyzer The OVF-3000 is light weight and portable, competitively priced compact and fully heated FID (HFID) based total hydrocarbon analyzer for high accuracy, sensitivity

More information