Thermal Process Validation Cooker Characterisation Temperature Distribution vs Heat Distribution
|
|
- Randolf Randolph Robertson
- 5 years ago
- Views:
Transcription
1 Thermal Process Validation Cooker Characterisation Temperature Distribution vs Heat Distribution Graham Bown, Thermal Process Specialist Food Manufacturing Technology: Process Support HPF MIG: 28 Jan 2016
2 The Issue Cooking assumes the same thermal process is delivered to each particulate / container so even-heating is a pre-requisite to satisfactory pasteurising and sterilising Applies to all cooking vessels including closed pasteurisers and sterilisers; batch and continuous (meat ovens, retorts, hydrostats etc) Closed cookers that contain air must avoid static air or air pockets to ensure heat transfer rates (to the product) are the same throughout the cooker Traditionally determined by studying temperature distribution throughout the cooker (eg, minimum 5 strategic points per retort basket) But air can be at the correct temperature and may only deliver 1/100 th to 1/1,000th of the energy otherwise delivered by the heating medium (steam, superheat water etc) So measuring temperature environment may not detect low heat transfer rates!
3 A Solution Measure the rate of heat transfer throughout the cooker Applied by measuring f h 1 throughout the cooker Has the advantage of indicating heat transfer rate with time throughout the cook Uses product simulants to avoid variables associated with real products and complex packages Uses lots of loggers 1: f h is the time taken to reduce the temperature difference between the heating temperature and a measured point, buy a factor of 10
4 Impact of air on f h in 3 retort styles Ongoing lab trials using PP blocks and identical loggers have shown: Style Time / temp Pressure % air 1 f h Time to F 0 >3min Pure steam Steam / air Raining Water 121.1C No over pressure None (!) 20.7min 25.9min 1.5bg 18% 21.7min 27.1min 3.0bg 49% 22.2min 27.8min 1.5bg 18% 21.2min 26.2min 3.0bg 49%?? Observations, in this instance: Presence of air reduces heat transfer rates (extends f h ) Presence of 49% air extends time to F 0 >3min by 1.9min all else equal Difficult to calculate f h (and j) consistently subjective asymptote selection based on the same Pure Steam time / temperature profile - using CTemp to calculate lethality for different f h values 1: Daulton s laws of partial pressure
5 Temperature vs Heat distribution Temperature Temperature with position and time Sensitive to time Limited use beyond first 5 min Relative to SP & MTI Indicates venting performance Heat Heat transfer rates with position and time Integrates over cycle Sensitive only during constant cooker temp Sensitive to cooker performance Calculations can be subjective Heat distribution Temperature distribution
6 Why now and Why us? US FDA is requesting Heat Distribution from those who use Steam /Air retorts, to support process filings both internally in the USA and from those that export to the USA IFTPS has issued a series of Thermal Process Protocols 1 including one for Heat Distribution to apply to all cookers that do not use pure steam (including Raining water and water spray retorts) US FDA may be about to adopt the IFTPS protocols EU directives re HACCP and English law Due Diligence defence suggest the need to evaluate and perhaps mitigate against the risks of air within cookers No evidence of food safety incidents due to entrapped / uncontrolled air probably because of the high level of industry awareness and good retort design 1: Guidelines For Conducting Thermal Processing Studies, IFTPS (2014)
7 Heat Distribution IFTPS: Experimental design Study minimum 5 points per basket positions as Temp Distribution Study all baskets per retort cycle At last 2 retort cycles (same start point, load, IT) Study full load and all permitted part load arrangements Include loggers at MTI & control probe & close to the fan (steam / air) Corroborate with pressure and heating media flowrates 5 basket retort requires at least 53 loggers!
8 Heat Distribution IFTPS: Success criteria To verify all positions are equal: Prior temperature distribution ΔT<±0.5 C Per retort: f h %CV 5% 1 (note: from a minimum of 2 cycles) If %CV>5%: Check accuracy, placement etc Run further trials Remedial engineering to improve slowest to heat location Slowest to heat location is the place to conduct heat penetration studies If %CV>5% and can t be improved: Slowest to heat location is the place to conduct heat penetration studies 1: %Coefficient of variance = σ x 100
9 Some issues Compliant temperature distribution is a prerequisite May double the data analysis required Requires the use of a simulant (bentonite, silicones, plastics) Requires works to demonstrate simulant function Involves additional costs and effort Logger conduction errors can become significant (impact on f h ) ComSol modelling accounts for errors associated with loggers with different length probes
10 A Campden View with your help - please FMT-PS is preparing a view on Heat Distribution: Should it / can it replace Temperature Distribution? Are the US FDA concerns real and appropriate in an EU context? Can the IFTPS protocols be implemented practically? Review Success criteria in a practical context (experimental error?) Does it change our view on cooker control and design? How to relate previous successful Temperature Distribution studies and reconcile differences with results from Heat Distribution studies? We will appreciate your inputs please - so we can represent an Industrial perspective Flora and Graham are to speak to the 2016 IFTPS Conference in 4 weeks Have you already had some experience with Heat Distribution that you can share with us - please? What do you need to know about Heat Distribution? Can we help?
11 IFTPS protocol: Comments so far Use actual retorts to perform heat penetration trials, loaded under actual conditions, using worst-case actual products packed in actual packaging under actual conditions. Use local environment loggers adjacent to every simulant block Use identical loggers in identical simulant blocks designed to reflect product f h Are 5 strategically placed simulants in each product stack enough? Are 2 or 3 replicate trials enough? Protocol applies equally to all cooker types that contain air by design or by poor practice (eg poorly vented steam retorts) Re-validate if programmed pressure changes or if product response to pressure changes (eg pouch geometry via filling conditions) Even carefully regulated trials produce %CV>1% amongst the blocks so consider extending cooker allowance in success criteria Need non-subjective method to calculate f h and estimate j
12 Timetable: Commit IFTPS paper 12 February (!) Draft White Paper: Heat Distribution: A Campden perspective IFTPS conference 23 to 25 February 29 April Presentation at next MIG 26 May Publish White Paper 30 June Appreciate any contributions during the next 2 weeks - please: graham.bown@campdenbri.co.uk
CHAPTER 13, SUBJECT 3 PROTOCOL FOR CARRYING OUT HEAT-PENETRATION STUDIES
13 3 1 CHAPTER 13, SUBJECT 3 Various methods and equipment may be employed in order to collect accurate heat-penetration data. The overall objective of these guidelines is to recommend procedures for carrying
More informationValidation of heat processes
5 Validation of heat processes G.S. Tucker, Campden & Chorleywood Food Research Association, Chipping Campden 5.1 Introduction: the need for better measurement and control There is an extensive range of
More informationTEMPERATURE AND HEAT DISTRIBUTION PROTOCOL FOR PROCESSING IN DISCONTINUOUS AGITATING RETORTS
Institute For Thermal Processing Specialists www.iftps.org 304 Stone Road West, Suite 301 Guelph, ON N1G 4W4 Phone (519) 824-6774. Fax (519) 824-6642 TEMPERATURE AND HEAT DISTRIBUTION PROTOCOL FOR PROCESSING
More informationCollecting data for modeling: Product heat penetration, equipment temperatures, and residence time
Collecting data for modeling: Product heat penetration, equipment temperatures, and residence time Presentation to the GMA Science Forum April 4, 2012 V1 David Anderson Food Safety Manager Del Monte Foods
More informationHazard Analysis Worksheet. Table #A-3 provides 6D process times for a range of cooking temperatures, with L. monocytogenes as the target pathogen.
Chapter 16: Pathogen Survival Through Cooking (A Biological Hazard) Hazard Analysis Worksheet STEP #10: UNDERST THE POTENTIAL HAZARD. Pathogen survival through a cook step can cause consumer illness. Cooking
More informationHeat Sterilization. Module- 40 Lec- 40. Dr. Shishir Sinha Dept. of Chemical Engineering IIT Roorkee
Heat Sterilization Module- 4 Lec- 4 Dr. Shishir Sinha Dept. of Chemical Engineering IIT Roorkee Sterilization is the total elimination of all microorganisms including spores Typically the last things to
More informationVerify Thermometer Accuracy at Your Critical Control Point! FEATURES CALIBRATION SERVICE
Verify Thermometer Accuracy at Your Critical Control Point! The Tel-Tru Check-Set Series of Thermometer Calibrators provides accurate, unambiguous, and cost-effective calibration and accuracy verification
More informationPRINCIPLES OF THERMAL PROCESSING
PRINCIPLES OF THERMAL PROCESSING The canning of foods has been practiced for almost 200 years, but the science supporting the canning process has been understood for only about half of that time. In this
More informationAseptic Process Validation
Aseptic Process Validation IMB GMP Information Seminar 27 th September 2012 Gerard Sheridan, Inspector Date Insert on Master Slide Slide 1 Overview Guidance Best Practices Common Deficiencies Slide 2 Aseptic
More informationMadgeTech Data Loggers
MadgeTech Data Loggers Patrick Gallagher Office: 603-456-2011 Cell: 724-591-4231 Email: pat@madgetech.com 879 Maple St Contoocook, NH 03278 www.madgetech.com -- Quality Assurance Quality assurance, or
More informationOven Validations and In-Bakery Data Collection at ARYZTA Bakeries for Baked Goods. Wafa Birbari, Ph.D. October 2018
Oven Validations and In-Bakery Data Collection at ARYZTA Bakeries for Baked Goods Wafa Birbari, Ph.D. October 2018 https://www.fda.gov/downloads/food/guidanceregulation/fsma/ucm517402.pdf HACCP Food Safety
More informationE3T Energy. Microwave Assisted Thermal Sterilization - MATS. Emerging Technologies Showcase. January 21, 2015
Microwave Assisted Thermal Sterilization - MATS Showcase January 21, 2015 Bill Wilson, P.E. Washington State University Extension Energy Program 1 GoToWebinar Logistics Minimize or maximize control panel
More informationValidation and Complete Routine Control Sets
Validation and Routine Control Sets Complete Validation Sets Complete Routine Control Sets Description: Validation data loggers with evaluation software and an extensive range of accessories German TÜV
More informationPROCESS VALIDATION ROCHAPON WACHAROTAYANKUN, PH.D.
Basic GMP Requirement PROCESS VALIDATION ROCHAPON WACHAROTAYANKUN, PH.D. Topic Process validation What and Why? Principle of process validation Manufacturing process validation Aseptic process validation
More informationImplementing a Food Safety Intervention Strategy
Implementing a Food Safety Intervention Strategy When planning an intervention, the most important variables to consider are the method, stage and time of application, equipment design and maintenance,
More informationValidation Considerations for New Technologies:
Validation Considerations for New Technologies: A Practitioner s Perspective 2012 GMA Science Forum Hormel Foods Originate, don t imitate George A. Hormel 1860-1946 So, What s New? Marketing just heard
More informationData Logger Systems. Medical CSSD Pharmaceutical Food
Data Logger Systems for Thermal Process Validation Medical CSSD Pharmaceutical Food Flexible Data Logger Systems For Thermal Validations ebro offers flexible measurement and documentation systems for validating
More informationEBI 12 The new data logger generation
EBI 12 The new data logger generation 3 EBI 12 The new data logger generation High quality stainless steel housing Application range from -90 C to 150 C High temperature accuracy up to 0.05 C Extended
More informationThermal Validation Solutions. TrackSense Pro. Pro. The ultimate solution in wireless thermal validation
TrackSense Pro TrackSense Pro The ultimate solution in wireless thermal validation Ultimate Solution in Wireless Thermal Validation Ellab has incorporated the latest in electronic technology and innovation
More informationAppendix A Compliance Guidelines For Meeting Lethality Performance Standards For Certain Meat And Poultry Products
Food Safety and Inspection Service United States Department of Agriculture Washington, D.C. 20250-3700 January 1999 Updated June 1999 Appendix A Compliance Guidelines For Meeting Lethality Performance
More informationBuying a New Lab or Industrial Furnace?
Buying a New Lab or Industrial Furnace? What should be considered when the time comes to purchase a new lab or industrial furnace? This article covers some of the questions that arise when specifying a
More informationCAE: Thermal Analysis
CAE: Thermal Analysis Using Digital Validation techniques to Reduce Product development cycle time Jayasimha Chalasani Mahindra Satyam Integrated Engineering Solutions Tool Snaps Analysis Snaps Brief Introduction
More informationThe HPA Guidelines for Assessing the Microbiological Safety of Ready-to-eat Foods placed on the market and. Hospital Guidelines
The HPA Guidelines for Assessing the Microbiological Safety of Ready-to-eat Foods placed on the market and Hospital Guidelines HPA FW&E Microbiology Service Developing Guidelines in Partnership FSA, Defra,
More informationTHERMAL PROPAGATION IN LITHIUM-ION BATTERIES
THERMAL PROPAGATION IN LITHIUM-ION BATTERIES Fredrik Larsson, PhD March 2018 Research Institutes of Sweden SAFETY AND TRANSPORT ELECTRONICS Gasoline very dangerous We have learnt how to make it safe Li-ion
More informationHACCP Principles & Application Guidelines
1 U.S. Food and Drug Administration Protecting and Promoting Your Health HACCP Principles & Application Guidelines Adopted August 14, 1997 NATIONAL ADVISORY COMMITTEE ON MICROBIOLOGICAL CRITERIA FOR FOODS
More informationTypes of Thermometers Used in the Seafood Industry
Types of Thermometers Used in the Seafood Industry Publication FST-295P Abigail Villalba, Extension Specialist, Virginia Seafood Agricultural Research and Extension Center, Virginia Tech Robert Lane, Extension
More informationMODEL VALIDATION FOR TEMPERATURE PROFILE INSIDE FFB DURING STERILIZATION FOR PALM OIL MILL PROCESS
MODEL VALIDATION FOR TEMPERATURE PROFILE INSIDE FFB DURING STERILIZATION FOR PALM OIL MILL PROCESS Arif bin Ab Hadi, Prof Dato Ir. Abd. Wahab Mohammad and Prof Ir. Mohd Sobri Takriff Department of Chemical
More informationNotified Bodies Recommendation Group
Notified Bodies Recommendation Group Recommendation for the Interpretation and Implementation of the Commission Recommendation on audits and assessments performed by notified bodies in the field of medical
More informationTop Seven Risks to Consider When Selecting a Life Science LMS
Top Seven s to Consider When Selecting a Life Science LMS THE UNINTENDED CONSEQUENCES OF UNINFORMED DECISIONS IN THIS PAPER: Identifying and avoiding gaps in LMS functionality that may lead to critical
More informationFlow Modeling for Chemical Processing
Flow Modeling for Chemical Processing Dr. Kevin W. Linfield, P.E. Engineering Director Livonia, Michigan ChemShow Nov 16-19, 2009 Booth #444 1 Outline Introduction Flow Problems in Chemical Processing
More informationTECHNICAL PAPER [Stockpile density]
TECHNICAL PAPER [Stockpile density] By BULK TESTING International Alain DELOYE CS 74114 F- 76020 Rouen Cedex adeloye@bti-europe.eu Tel 33 235 71 17 60 Abstract Reporting tonnages of stockpiled material
More informationWireless Data Logger System
Wireless Data Logger System for Thermal Process Validation Medical / CSSD / Pharmaceutical / Food Flexible Data Logger System For Thermal Validations ebro offers a flexible measurement and documentation
More informationSyl-Off Emulsion, Platinum-Catalyzed Silicone Release Coatings from Dow Corning
Syl-Off Emulsion, Platinum-Catalyzed Silicone Release Coatings from Dow Corning Release System Information Guide Features Low silicone coat weights possible A wide range of substrates possible Cured coatings
More informationIndustry Best Practices
Industry Best Practices E. Coli O157 Surveillance and Prevention Briefing Arlington VA, January 23, 2008 Beef Best Practice Overview Coordinated through Beef Industry Food Safety Council (BIFSCO) Best
More informationThe National Renderers Association, The World Renderers Organization & The North American Rendering Industry. Tom Cook, President
National Renderers Association The National Renderers Association, The World Renderers Organization & The North American Rendering Industry Tom Cook, President National Renderers Association The Rendering
More informationThermal Validation Solutions. TrackSense Pro. Pro. The ultimate solution in wireless thermal validation
Thermal Validation Solutions TrackSense Pro TrackSense Pro The ultimate solution in wireless thermal validation The Ultimate Solution in Wireless Thermal Validation TrackSense Pro Ellab has incorporated
More informationPlastic Filter Housings
PFG754 Plastic Filter Housings For a range of liquid applications Our plastic filter housings are ideal for use within a wide range of industries where filtered liquids must remain free of contamination.
More informationPDA: A Global. Association. Matrix Approach to Media Fills. (c) 2012 Catalent Pharma Solutions. All rights reserved.
PDA: A Global Matrix Approach to Media Fills Association (c) 2012 Catalent Pharma Solutions. All rights reserved. Overview Guidance Overview Matrix Introduction Why Matrix Media Fills Sample Matrix New
More informationPresentation to Institute of Technology Tralee. 26 th March 2013
Presentation to Institute of Technology Tralee 26 th March 2013 Metal Improvement Company LLC A Subsidiary of Curtiss-Wright Corporation Our Corporate Profile Today A strategically focused multinational
More informationThe Bowie & Dick test is used by manufacturers
Keywords steam steriliser performance evaluation helix test Performance Evaluation of Hospital Steam Sterilisers Using the European Helix Test A.C.P. de Bruijn*, A.W. van Drongelen The Bowie & Dick test
More informationTechnology Overview. Ethylene Oxide
Technology Overview Ethylene Oxide The Synergy Health Ethylene Oxide processing service offers: Cycle optimisation Improved turnaround times Flexible validation options Parametric release Research & development
More informationSupplier and External Manufacturer Requirements Manual
Supplier and External Manufacturer Requirements Manual ArdentMills.com TP0115 2017 Ardent Mills Introduction One of the core values of Ardent Mills is nourishing people and ensuring that our food and animal
More informationLifecycle of NIR Analytical Methods: Regulatory Perspective
Lifecycle of NIR Analytical Methods: Regulatory Perspective Bogdan Kurtyka, Ph.D. FDA/OPQ/OPF IFPAC Annual Meeting January 27, 2015 Outline Method lifecycle Impact of selected elements of lifecycle on
More informationUnannounced Visits. Welcome! We will start the webinar presentation at 9am. Copyright 2014 BSI. All rights reserved.
Unannounced Visits Welcome! We will start the webinar presentation at 9am Copyright 2014 BSI. All rights reserved. Unannounced Visits John Howlett Head of Notified Body Vicky Medley Head of QMS Copyright
More informationZealaFoam A Functional Alternative to Polystyrene Foam
ZealaFoam A Functional Alternative to Polystyrene Foam Outline Biopolymer Network Ltd The ZealaFoam process Fish box production and testing Scale up and current research Biopolymer Network Limited Biopolymer
More informationDETERMINATION OF OPTIMUM STERILIZATION CONDITION BASED ON CALCULATED HEAT TRANSFER RATE FOR PALM OIL MILL PROCESS
DETERMINATION OF OPTIMUM STERILIZATION CONDITION BASED ON CALCULATED HEAT TRANSFER RATE FOR PALM OIL MILL PROCESS Arif bin Ab Hadi, Dato Ir. Abd. Wahab Mohammad and Ir. Mohd Sobri Takriff Department of
More informationSurface pasteurisation of shell eggs
Journal of Food Engineering 53 (2002) 193 197 www.elsevier.com/locate/jfoodeng Surface pasteurisation of shell eggs C. James *, V. Lechevalier, L. Ketteringham MAFF Advanced Fellowship in Food Process
More informationSA Good Agric. Practices and how it relates to Globally recognized GAP s
SA Good Agric. Practices and how it relates to Globally recognized GAP s -International food safety restrictions and requirements when exporting- International Harmonization Workshop on Commercial Quality
More informationTMI-Orion Pharmaceutical Medical
INDUSTRY FLYER TMI-Orion Pharmaceutical Medical HIGH TECH DATA LOGGING SOLUTIONS www.tmi-orion.com TMI-Orion Pharmaceutical Medical TMI-Orion presents a full range of high tech data loggers designed for
More informationTMI-Orion Pharmaceutical Medical
INDUSTRY FLYER TMI-Orion Pharmaceutical Medical HIGH TECH DATA LOGGING SOLUTIONS www.tmi-orion.com TMI-Orion Pharmaceutical Medical TMI-Orion presents a full range of high tech data loggers designed for
More informationProfile the easy way..
Profile the easy way.. The need for continuous monitoring The classical way to obtain a temperature profile is to attach thermocouple sensors to the PCB and record the temperature profile using a heat
More informationImplementation Plan Project Operations Personnel Training
Implementation Plan Project 2010-01 Operations Personnel Training Implementation Plan for PER-005-2 Operations Personnel Training Approvals Required PER-005-2 Operations Personnel Training Prerequisite
More informationMILLING INDUSTRY QUALITY ASSURANCE PRINCIPLES AND PRACTICES. Philip Randall (with contributions from Quentin Johnson)
MILLING INDUSTRY QUALITY ASSURANCE PRINCIPLES AND PRACTICES Philip Randall (with contributions from Quentin Johnson) WWW.DIFFEN.COM/DIFFERENCE/QUALITY_ ASSURANCE_VS_QUALITY_CONTROL Quality Assurance is
More informationGFSI BENCHMARKING REQUIREMENTS GFSI GUIDANCE DOCUMENT VERSION 7.2 PART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS
GFSI BENCHMARKING REQUIREMENTS GFSI GUIDANCE DOCUMENT VERSION 7.2 PART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS The GFSI Benchmarking Requirements version 7.2 Part III - EI Processing of animal
More informationTMI-Orion Pharmaceutical Medical
INDUSTRY FLYER TMI-Orion Pharmaceutical Medical HIGH TECH DATA LOGGING SOLUTIONS www.tmi-orion.com TMI-Orion Pharmaceutical Medical TMI-Orion presents a full range of high tech data loggers designed for
More informationNarrative. Description of Process: REVISED JUNE 2017 Commercial Processing Example: Shrimp (Wild), Cooked, Frozen. ABC Shrimp Company, Anywhere, USA
National Seafood HACCP Alliance for Training and Education REVISED JUNE 2017 Commercial Processing Example: Shrimp (Wild), Cooked, Frozen Example: This is a Special Training Model for illustrative purposes
More informationPART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS
PART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS GFSI TECHNICAL EQUIVALENCE GFSI Guidance Document PART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS Certification Programme Scope and Key Elements
More informationGFSI BENCHMARKING REQUIREMENTS GFSI Guidance Document Version 7.2 PART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS
GFSI BENCHMARKING REQUIREMENTS GFSI Guidance Document PART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS PART III - EI PROCESSING OF ANIMAL PERISHABLE PRODUCTS Certification Programme Scope and Key
More informationSTATEMENT OF COMPLIANCE (HACCP-PREERQUISITES LETTER) December 2016
STATEMENT OF COMPLIANCE (HACCP-PREERQUISITES LETTER) December 2016 1 APPROVALS AND CERTIFICATIONS Frigorífico Marfrig Global Foods S.A., Establishment Nº2500 is approved by the European Commission (Food
More information2016 VMA Technical Seminar Fugitive emission testing and certification of valves What we will have to do next? David Bayreuther March 10, 2016
2016 VMA Technical Seminar Fugitive emission testing and certification of valves What we will have to do next? David Bayreuther March 10, 2016 Outline Sources of emissions History of legislation Review
More informationSTATEMENT OF COMPLIANCE (HACCP-PREERQUISITES LETTER) July 2015
STATEMENT OF COMPLIANCE (HACCP-PREERQUISITES LETTER) July 2015 1 APPROVALS AND CERTIFICATIONS Frigorífico Tacuarembó S.A., Establishment Nº12 is approved by the European Commission (Food and Veterinary
More informationApproaches to minimize Printed Circuit Board (PCB) warpage in Board Assembly Process to improve SMT Yield
Approaches to minimize Printed Circuit Board (PCB) warpage in Board Assembly Process to improve SMT Yield Initiative Leaders: Srini Aravamudhan & Chris Combs, Intel; inemi Staff: Haley Fu The Project Development
More informationTMI-Orion Pharmaceutical Medical
INDUSTRY FLYER TMI-Orion Pharmaceutical Medical HIGH TECH DATA LOGGING SOLUTIONS www.tmi-orion.com TMI-Orion Pharmaceutical Medical TMI-Orion presents a full range of high tech data loggers designed for
More informationPOL: 08:VP:003:03:NIBT PAGE : 1 of 7
POL: 08:VP:003:03:NIBT PAGE : 1 of 7 Northern Ireland Blood Transfusion Service POLICY DOCUMENT Document Details Document Number: POL:08:VP:003:03:NIBT No. of Appendices: 2 Supersedes Number: 08:02:VP:003:NIBT
More informationPerformance Evaluation Performance (PEP) Preliminary Results Report 3 & 5 July 2017
Performance Evaluation Performance (PEP) Report 3 & 5 July 217 Solar Cooker: CooKit Manufacturer: Solar Cookers International Cookware: Granite Ware Greenhouse material: Plastic Bag (oven bag) Standard
More informationCV-1500 CONTROLLED VOLATILITY ELECTRICALLY CONDUCTIVE RTV SILICONE ADHESIVE/SEALANT
ADVANCED ENGINEERING CV-1500 CONTROLLED VOLATILITY ELECTRICALLY CONDUCTIVE RTV SILICONE ADHESIVE/SEALANT DESCRIPTION APPLICATION One-part, black, electrically conductive RTV silicone Non-corrosive and
More informationCV-2646 CONTROLLED VOLATILITY ELECTRICALLY CONDUCTIVE RTV SILICONE
ADVANCED ENGINEERING CV-2646 CONTROLLED VOLATILITY ELECTRICALLY CONDUCTIVE RTV SILICONE DESCRIPTION APPLICATION Two-part, tan-colored electrically conductive RTV silicone 100:0.5 Mix Ratio (Base: Curing
More informationHow Packaging Regulations Can Drive Packaging Innovation
How Packaging Regulations Can Drive Packaging Innovation Lithium Battery Panel Discussion for the 2018 Labelmaster Dangerous Goods Symposium 7 September 2018 James Jones Director Product & Quality Management
More informationCreating Hazard Analysis and Critical Control Point (HACCP) Plans that are FSIS-Compliant
Creating Hazard Analysis and Critical Control Point (HACCP) Plans that are FSIS-Compliant Every meat and poultry processor in the United States must create a Hazard Analysis and Critical Control Point
More informationq Conclusions q Oil Shale panorama Different Process industrial scale q The Ecoshale TM In-Capsule Process
AGENDA q Oil Shale panorama Different Process Methods@ industrial scale q The Ecoshale TM In-Capsule Process q Technology concept q Ecoshale TM Technology vs. Other Ex Situ Processes q Ecoshale TM Technology
More informationWritten By Dr. Robert Ramaley (Univ. NE Med CTR), Mia Ware, Dan Pearson, and Christopher R. Dwyer* (Raven Biological Laboratories)
Performance Comparison for Three Types of Biological Indicators Used in Steam Sterilization Processes: Spore Strips, Crushable Self-contained, and Sealed Glass Ampoule Written By Dr. Robert Ramaley (Univ.
More informationOrange G: 102 B: 0. NAICC Annual Meeting St. Louis, MO Author, Date (Arial, Bold, 24) 1. NAICC Annual Meeting St.
Orange Pollinator R: 204 Studies Key Presentation title Points (Arial, for Bold, Auditors 32) G: 102 B: 0 NAICC Annual Meeting St. Louis, MO 2017 Author, Date (Arial, Bold, 24) 1 Acknowledgements Anna
More informationA Strategy for Controlling Histamine Formation at Tuna Precooking
PEER-REVIEWED ARTICLE Food Protection Trends, Vol 37, No. 5, p. 340 352 Copyright 2017, International Association for Food Protection 6200 Aurora Ave., Suite 200W, Des Moines, IA 50322-2864 John DeBeer,
More informationStack Testing & Parameter Monitoring in the Flexible Packaging Industry
Stack Testing & Parameter Monitoring in the Flexible Packaging Industry Avoiding Common Pitfalls Greg Verret, P.E. Principal, Air Sciences ENVIRON International Corporation (636) 498-4447 When Is Testing
More informationA Coupled Thermal and Mechanical Model of Sliding Wear
9 th International LS-DYNA Users Conference Simulation Technology (4) A Coupled Thermal and Mechanical Model of Sliding Wear S. S. Akarca, W. J. Altenhof, and A. T. Alpas Department of Mechanical, Automotive,
More informationFeb 2013 ASM Pune Chapter Conference. High Speed Tempering of Gears: A Comparative Study. Gear Technology Going Global
Feb 2013 ASM Pune Chapter Conference Authors: Gorphade, P., Gowri, S., Grenier, M (2013) High Speed Tempering of Gears: A Comparative Study Gear Technology Going Global Abstract Tempering is a time temperature
More informationPerformance Evaluation Performance (PEP) Preliminary Results Report 31 July 2017
Performance Evaluation Performance (PEP) Report 31 July 217 Solar Cooker: Sport with Reflector Manufacturer: Solavore Cookware: Granite Ware Greenhouse material: None Standard Cooking Power: 5.5 Watts
More informationTemperature mapping and autoclave validation specialists
www.thermalcompliance.co.uk Temperature mapping and autoclave validation specialists Who are we? We are Thermal Compliance, specialists in temperature mapping and autoclave validation. Founded in 2007,
More informationAchieving FSIS HACCP Validation Compliance. March 15 th and 17 th, 2016
Achieving FSIS HACCP Validation Compliance March 15 th and 17 th, 2016 Questions? Please use the Chat function on the upper right hand of your screen. Send your questions to Michelle Rossman and she will
More informationUsing Simulation Model to Reduce System Design Time and Cost
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Using Simulation Model to Reduce System Design Time and Cost Vijay Bahel
More informationPerformance Evaluation Performance (PEP) Preliminary Results Report 31 July 2017
Performance Evaluation Performance (PEP) Report 31 July 217 Solar Cooker: SK-14 Manufacturer: Muni Seva Ashram Cookware: Granite Ware Greenhouse material: None Standard Cooking Power: 347 Watts SCI Test
More informationMANAGEMENT AND REQUALIFICATION OF STERILISATION PROCESSES
SUMMARY The Annexe 1 requirement for the annual requalification of sterilization processes is a huge resource requirement as well as a significant amount of downtime for many sites running complex sterilisation
More informationBRC Storage and Distribution Quality and Safety Management System
This is an ideal package for Storage and Distribution companies looking to meet International Quality and Safety Standards. This manual meets the requirements of the British Retail Consortium Global Standard
More informationLeveraging Health Canada s Regulatory Framework to Accommodate Accelerated Product Development for Biologic Drugs
Leveraging Health Canada s Regulatory Framework to Accommodate Accelerated Product Development for Biologic Drugs Nancy Green, Ph.D. Chief, Hormones and Enzymes Division Biologics and Genetic Therapies
More informationIntroduction to Temperature Mapping of Controlled Temperature Storage Areas Temperature Mapping 101. Presented by Grant South 7 February, 2018
Introduction to Temperature Mapping of Controlled Temperature Storage Areas Temperature Mapping 101 Presented by Grant South 7 February, 2018 Welcome Introduction to temperature mapping What and why GMP
More informationIndustry Standard. Meat Retail Ready Packing Operations
Industry Standard Meat Retail Ready Packing Operations Contents Page No. 1. Introduction 2 2. Objective 3 3. Product Design 3 4. Control of Product Rework 4 5. Approved Suppliers 5 6. Species Contamination
More informationDeloitte Shared Services Conference 2018 Extended lab 4: Internal controls managing risk in the age of digitalisation Ani Sen Gupta and Edward
Deloitte Shared Services Conference 2018 Extended lab 4: Internal controls managing risk in the age of digitalisation Ani Sen Gupta and Edward Litchfield, Deloitte Industry context and direction of travel
More informationHow to Map a Warehouse. Mapping & Monitoring for Controlled Environments
How to Map a Warehouse Mapping & Monitoring for Controlled Environments Webinar Presenters & Humidity Experts Bruce McDuffee Steve Chenal Agenda & Takeaways Agenda Regulations & Guidance Overview Step
More informationIntroduction and Background
Introduction and Background Validation of Biotech Facilities Pacific Biotech Alliance Robert J. Mackey Pacific Biotech Alliance is an established consulting firm in the Pacific Northwest that specializes
More informationResolving Vapor Intrusion Challenges via Automated Continuous Real-Time Monitoring and Response
Resolving Vapor Intrusion Challenges via Automated Continuous Real-Time Monitoring and Response Blayne Hartman Ph.D. 858-204-6170 www.hartmaneg.com Mark Kram, Ph.D. 805-899-8142 www.groundswelltech.com
More informationComplaints Investigations Root Cause Analysis
Complaints Investigations Root Cause Analysis Dr. Ademola Daramola International Relations Specialist Drugs US FDA India Office New Delhi February 22nd 2018 Information presented in this presentation does
More informationThermal Runaway Initiation and Propagation Review and Potential Test Procedure
Thermal Runaway Initiation and Propagation Review and Potential Test Procedure Dean MacNeil Team Leader, Research Officer Energy, Mining and Environment Ottawa 613-990-1769 Co-authors : NRC : Steven Recoskie,
More informationCurrent Moist Heat Sterilization and Validation Seminar
Current Moist Heat Sterilization and Validation Seminar Keith Shuttleworth is the Senior Consultant at Keith Shuttleworth & Associates Ltd, which provides a range of specialist products, consultancy and
More informationWHY IS THERE A NEED FOR MORE ACCURACY IN DRY KILN CONTROL
WHY IS THERE A NEED FOR MORE ACCURACY IN DRY KILN CONTROL Leon Breckenridge Integrated Energy Economic Services, Inc. Yakima, Washington INTRODUCTION Section A Parameters for Measurement and Control The
More informationWCG ACADEMY COURSE OVERVIEW
WCG ACADEMY COURSE OVERVIEW Investigator Course Title Documentation of Informed Consent Duration Ethical Principles Underlying Consent Documentation Long Form Short Form Consent Records Special Considerations
More informationHistorical Review: Fast & micro Gas Chromatography
Historical Review: Fast & micro Gas Chromatography Dr. Ed Overton, Professor Emeritus Department of Environmental Sciences Louisiana State University School of the Coast & Environment Presenter: John Crandall
More informationIFSQN Validation Blog References January 2015
(1) Codex GUIDELINES FOR THE VALIDATION OF FOOD SAFETY CONTROL MEASURES CAC/GL 69-2008 Validation: Obtaining evidence that a control measure or combination of control measures, if properly implemented,
More informationPresentation to Pacific Value Chains Conference Nadi, 18 April 2013
Presentation to Pacific Value Chains Conference Nadi, 18 April 2013 PHAMA GOAL & OBJECTIVE GOAL Increased exports of high value primary products, contributing to economic growth and improved rural livelihoods.
More informationTOP FIVE TIPS. Autoclave Validation. Create & Maintain Clear Validation Protocols. Begin Your Regimen with a Bowie-Dick Test
Autoclave Validation TOP FIVE TIPS Time and Money Saving Validation Strategies 1 2 Create & Maintain Clear Validation Protocols Begin Your Regimen with a Bowie-Dick Test 3 Use Autoclave-Friendly Data Loggers
More informationRegulatory Update. Paul Sexton. QP Forum
Regulatory Update Paul Sexton QP Forum 16 th April, 2015 Content Updates on GMP Guidance Updates on EU Legislation Draft Ph Eur monograph on WFI including RO 2 Chapter 5 - Production Paragraphs 27 to 30
More information