ProJet MJP 2500, MJP 2500 Plus & MJP 2500W
|
|
- Ronald Skinner
- 6 years ago
- Views:
Transcription
1 Facility Requirements Guide ProJet MJP 2500, MJP 2500 Plus & MJP 2500W Facility Requirements Guide p/n 33-D131 Rev C Original Instructions Please refer back to for the most up-to-date facility requirements guide About This Manual This document includes the overall facility requirements that will be needed to have a successful installation when our authorized 3D Systems representatives arrive to install your 3D printer system.
2 What is a Facility Requirements Guide This guide provides important information on selecting a facility location and planning for the installation of 3D Systems ProJet MJP 2500 Professional Printing System. It also presents planning guidelines to facilitate fast, convenient installation and operation of your 3D printer system. What s Inside: Descriptions of hardware, software, part material, networking components, and documentation that comprise the ProJet MJP 2500 Professional Printing System. An overview of the site requirements in typical engineering and design work spaces. These involve basic access, electrical, and environmental conditions for configuring a safe and efficient work area. A checklist is included to ensure that the facility is adequately prepared for installation of your 3D printer system. Information on how to obtain assistance from 3D Systems Customer Support Team.
3 Common Symbols Used Throughout 3D Systems Manuals The ProJet MJP 2500 Professional Printing System is part of 3D Systems Multi-Jet-Printing (MJP) product line. UV RADIATION HAZARD: Invisible UV radiation is accessible in the vicinity of this sign or behind the panel. Radiation can cause eye injury or blindness, burn injury and/or fire. Access panels are for service only and should be opened only by certified service personnel (ProJet 2500/2500 Plus only) ELECTRICAL SHOCK HAZARD: High voltage electricity is accessible in the vicinity of this sign or behind the access panel. High voltage can cause severe burns or death, as well as fires. Access panels are for service only and should be opened only by certified service personnel or trained maintenance personnel. HOT SURFACE HAZARD: A hot surface is accessible in the vicinity of this sign or behind the access panel. Avoid contact. Hot surfaces can cause burn injury or fire. Allow surface to cool before touching. Access panels are for service only and should be opened only by certified service personnel or trained maintenance personnel. THIS GLOBAL HARMONIZED SYSTEM LABEL FOR LOW LEVEL TOXICITY. THIS INCLUDES RESPIRATORY, SKIN, AND EYE IRRITATION, SKIN SENSITISERS AND CHEMICALS HARMFUL IF SWALLOWED, INHALED OR IN CONTACT WITH SKIN. CAUTION: Indicates the possibility of loss of data or damage to equipment. WARNING: INDICATES THE POSSIBILITY OF INJURY OR DEATH TO PERSONNEL. HAND ENTANGLEMENT WARNING: GEARS OR MOVING PARTS HAZARD IN THE VICINITY OF THIS SIGN OR BEHIND THE ACCESS PANEL. ACCESS PANELS ARE FOR SERVICE ONLY AND SHOULD BE OPENED ONLY BY AUTHORIZED SERVICE PERSONNEL. WEAR GLOVES: Wear the appropriate gloves when required. For example, when touching surfaces that may contain or have been exposed to materials, wear nitrile gloves. Heat gloves are necessary when touching surfaces that may be hot to ensure burns don t occur. ULTRAVIOLET RADIATION INSIDE: Exposure may cause eye damage. Do not operate without covers. Wear UV eye protection. NOTE: A note signifies important information but not information of a critical content.
4 The ProJet Professional Printing System Your ProJet MJP 2500 Series Printer ships with the following: One crated ProJet MJP 2500 Professional Printing System containing the following accessories and materials. Two Build Platforms (one on the printer and one in an accessory box) Region-specific country kit consisting of one power cable Two full cartridges of VisiJet Part Material and two full cartridge of Support Material One pack of nitrile gloves 10 Waste Bags 2 cartridge holders SIM card (ProJet MJP 2500 Plus only)
5 Preparation for Shipment Arrival The following topics should be arranged PRIOR TO THE ARRIVAL OF THE SYSTEM, to simplify installation of the ProJet MJP 2500 Professional Printing Systems. Make sure the following resources are available: A forklift or similar, heavy-duty equipment required for unloading the 3D printer system crate from the truck to the de-crating location. (Forklift is not required to move 3D printer system into where it will be installed once the crate is removed.) Network connection(s) Power outlet(s) - a dedicated circuit to power the 3D printer system Storage cabinetry for extra 3D printer system material containers and other consumables At least one (1), networked graphics workstation or CAD/CAM/CAE terminal meeting the requirements described in Client Workstation Requirements. NOTE: Retain the shipping crate, ramps, brackets and hardware in the event the ProJet MJP 2500 Professional Printing System needs to be shipped in the future. These crates are designed to allow fast, easy removal and packaging of the product. If 3D printer system needs to be shipped, contact 3D Systems Customer Support for shipping instructions.
6 Facility Guidelines This section provides details relating to site selection, site preparation and readiness of the facility to accept and install the ProJet 2500 Professional Printing System. Discuss the appropriate equipment locations with a 3D Systems' Certified Partner, so that the equipment is located in a convenient, appropriate location based on your organization's needs. When planning an installation, consider. Electrical Requirements Space Planning Access Area Surrounding 3D Printer System Network Interface Post Processing Accessories (Oven and Freezer) Material Storage Unit Portability Material Bottle Disposal Client Workstation Requirements Printer Weights and Printer Dimensions Electrical Requirements for the ProJet MJP 2500 Series Printer: Space Planning An additional 100 or 220 VAC outlet is recommended for service needs. The outlet location must be near the 3D printer system and remain accessible to the end user at all times. A phone near the 3D printer system is recommended to facilitate 3D printer system support. Each location of the 3D printer system requires a standard wall power outlet or power drop to power the 3D printer system. AC Voltage and Current Requirements: Each 3D printer system requires use of a dedicated circuit that will allow for VAC, 50/60 Hz, 15A, single phase or VAC, 50 Hz, 10A, single phase Single C14 receptacle. All ProJet MJP 2500 series printers relies on a connection to the mains protective earth (ground). This provides a one level of protection to the user (Basic Insulation). The installation of The ProJet MJP 2500 Professional Printing System shall comply with the National Standards of the country in which it is placed. Protected Power/Un-interruptible Power Many customers face AC power quality issues requiring the use of a UPS (Uninterruptible Power Supply) and generator to correct. The primary function of a UPS is to hold up AC power for a limited period of time by using energy from rechargeable batteries. For brief power outages, a UPS is sufficient; the amount of holdup time may also be scaled with additional battery packs according to customer needs. For extended power outages, some combination of UPS and on-site generator is required. The secondary benefits of a UPS often include line conditioning (correcting for voltage sags and swells) and line surge protection. A double-conversion, true sine-wave UPS is recommended as it provides additional immunity from powerline perturbations. 3D Systems has tested the product with the following UPS models: North America Manufacturer Model Voltage In Voltage Out kw Input Connector Output Connector(s) APC SURTA3000XL L5-30P 5-20R Eaton 9PX3000RT L5-30P 5-20R, L5-30R Liebert GXT4-3000RT L5-30P 5-20R, L5-30R
7 Worldwide Manufacturer Model Voltage In Voltage Out kw Input Connector Output Connector(s) APC SRT3000XLW-IEC 208/ C20 IEC C13, IEC C19 Eaton 9PX3000GRT 208/ C20 IEC C13, IEC C19 Any UPS unit will impose additional facilities considerations including battery storage, floor space, interconnect and electrical receptacle requirements. For example, the above North-America UPS models require an L5-30 receptacle. If additional or substitute cordsets are required, the cordset shall be rated greater than or equal to the input current rating of the product at the voltage applied. For example, a C13 to C14 cordset will be required if the UPS provides C13 receptacles (typical in markets outside North America). Recognizing that customer needs and facilities differ greatly, 3D Systems encourages customers to contact one of the above UPS manufacturers for a power protection solution tailored to the customer and site needs. ProJet XL Finisher (Optional) Power Requirements The ProJet XL Finisher must be hardwired and installed by a Certified Electrician. For more information about the ProJet XL Finisher click here. Client Workstation Requirements Before a print can be printed on the printer, the print data file must be saved or exported to the industry-standard.stl file format, and submitted over the network. 3D SPRINT client software is located on 3DS Central can be installed on each intended users workstation to allow them to select, preview, and submit jobs; as well as manage the print queue. For more information on sending a file to the 3D printer system see the ProJet MJP 2500 User s Guide available on: (Acrylate) (Wax) Prior to installing the software, ensure that the initially selected workstation meets the following minimum specifications. Although the ProJet 2500 client software will run on less powerful computers, meeting the minimum recommended configuration will ensure acceptable performance. It is recommended that this workstation be further enhanced with the recommended requirements for maximum performance, particularly with more powerful processors and added memory. System Requirements OS CPU RAM Minimum - Windows 7 (64-bit) -Windows 8 (64-bit) -Windows 10 (64-bit) - Intel or AMD processor with a minimum of 2.0GHz -4 GB Recommended - Multiple core processor - Hyper threading and clock speeds above 3GHz can be beneficial but should be paired with a good balance of cores. - 8GB or more - Virtual Memory: In Win 7, Win 8, Win 10, it is recommended to use the default option; "Automatically manage paging file size for all drives"
8 Hard Disk Display/GPU Other -30 GB of available hard-disk space for cache -Temporary file cache requires about 3GB free disk space for optimal print file transfers -Open GL 2.1 and GLSL 1.20 enabled graphics card -Screen resolution 1280x960 -Internet Explorer 9 or newer -Microsoft.NET Framework 4.5 (installed with application) -3 button mouse with scroll -Keyboard -SSD or 10,000RPM HDD -NVidia or AMD GPU with 1GB of RAM or more -Screen resolution 1280x1024 or higher -Google Chrome or Internet Explorer 11 I/O -Either ethernet or wireless connection -Ethernet may be more stable depending on the facility Network Interface The ProJet 2500 Professional Printing System requires an Ethernet network connection to transfer print jobs from workstation(s) to the printer. An established TCP/IP network is setup and enabled. An RJ45 Ethernet network connection for each printer to be installed at the delivery site must be installed, tested and functioning. The printer can use either DHCP or a static assigned IP address. A DHCP server automatically programs an IP address; otherwise, a network administrator can manually assign a permanent IP address for each printer that is to be connected to the network. Write IP address(es) here: Space Planning Included in this guide is information and dimensions required to help plan installation of the printer. Crated Clearance The 3D printer system is intended to be lifted from the shipping truck using a forklift. Have a forklift available for the 3D Systems Customer Support Engineer (CSE) or reseller when installation occurs. The crate can then be removed, and the ramps placed as shown below. Store crate pieces where it will be easy to access should the printer need to be sent back or shipped to another location. Based on the crate size, you must have at least 192 (488mm) (approx. 16 ) to accommodate the pallet, ramps and printer, the required footprint to uncrate is approximately 7 x 16.(2.13x4.88m) CAUTION: NEVER unpack, assemble, or connect any component of the shipment without the aid of a qualified, 3D Systems Customer Support Engineer or certified partner. 3D Systems accepts no responsibility for damaged, defective, or incomplete systems uncrated by anyone other than 3D Systems Customer Support Engineer or certified partner.
9 Crate Dimensions and Weight Requirement Metric English Crated size 1435mm x 927.1mm x mm (L x W x H) 56.5 x 36.5 x Crated weight 324kg 715 lbs. Uncrated size mm x 741.7mm x mm (L x W x H) 44 x 29 x 41.8 Uncrated weight 211kg 465 lbs. Floor Flatness / Level 2.5cm over 12m 1 over 3
10 Unit Portability The ProJet 2500 Printing System is equipped with four caster-type rollers and four leveling feet. Leveling can be adjusted by locking the casters in place while adjusting leveling feet as required until 3D printer system is level. Access Area Surrounding Uncrated 3D Printer System At least 12" (30cm) of unobstructed floor space is recommended behind and on either side of the printer for airflow with 18" (46cm) in front of the printer to be able to open the material drawer. It is recommended that 36" (91cm) either behind or in front of the printer for service access. Behind would allow service to obtain access from the back, if the space is left in front, the printer will need to be moved out away from wall using that space in front to do so.
11 Freezer A freezer is recommended but not mandatory for easy part removal. If you decide to include a freezer as part of your post processing equipment ensure that it will accommodate the maximum build size of 12 x 6 x 8 (L x W x H). Any standard freezer capable of accommodating this size will be sufficient. Material Storage VisiJet part and VisiJet support materials should be stored in a conveniently located storage cabinet in proximity to the printer. A cabinet is recommended to protect against long term exposure to external UV light sources, including sunlight, overhead lighting, or other UV light sources. Storage temperature of the material should not exceed the specified maximum of 35 C (95 F). VisiJet part material should be stored away from strong oxidizing agents, such as hydrogen peroxide, bromine, or chromic acid.
12 NOTE: When storing material cartridges that have been used but still have materials in the cartridges, do not lay the cartridges on their side in storage. Store box with side spacers installed. *DO NOT rest on nose of cartridge. Also, in the case where used cartridges with materials are removed from the MDM and are still warm, it must be stored with the cap vented. If the warm cartridge is not vented, the wax will contract during cooling and the cartridge's bottom may become flat which will prevent re-engagement in the MDM. More detailed information on the VisiJet build material and VisiJet support material, relevant applicable safety precautions and remediation, and specific storage and disposal requirements, can be found in the Global Harmonized Standards / Safety Data Sheets (GHS/MSDS). Your organizations' Facilities Manager (or equivalent) should maintain a copy of the two GHS/MSDS documents, and provide ready, convenient access to these documents. To obtain the VisiJet material GHS/MSDS from 3D Systems, go to If further information is needed, please contact 3D Systems' Customer Hotline within the U.S. at (800) (or from outside the U.S.A. at +49 (0) ), or by visiting 3D Systems website. Material Cartridge Disposal Used part material cartridges must be disposed of in a manner consistent with local and other applicable laws and regulations governing such materials. Refer to the VisiJet materials' GHS/SDS Global Harmonized Standards/Safety Data Sheets prior to shipment of the printer. Discuss your organization's methods for disposing or recycling of such material with your facilities manager, or for more information, contact 3D Systems' Customer Support Hotline.
13 Operating Environment Locate the 3D printer system in a convenient location meeting the requirements specified in this document. To ensure optimum performance, it is important that the printer be installed in a clean, dry, air-conditioned room. Avoid placing the printer in any environment with airborne contaminants, including cigarette smoke, fumes, and mechanical particulates that can adversely affect the long term functioning of the equipment. Each 3D printer system undergoes an operational test at the factory, and is shipped with (2) full cartridges of part material and (2) full cartridges of support material. Caution: Estimated printing times can be off if ambient temperature exceeds what is required. Using VisiJet M2G-DUR (ProFlex) and VisiJet M2G-CL (Armor) The (2) engineering materials, VisiJet M2G-DUR (ProFlex) and VisiJet M2G-CL (Armor) use advanced chemistry that produces a stronger odor that may not be suitable for all office environments. There are no safety hazards in the odor but this could be a nuisance, especially to people who are generally hypersensitive to strong odors. Air Conditioning A number of the ProJet MJP 2500 System s internal electronic components as well as the part material, are sensitive both to ambient temperature and, to some extent, humidity. In addition, the build process itself can be temperature-sensitive within certain limits. The operating temperature range should be between C (64-82 F); optimal temperatures being C (64-75 F). The facility air conditioning system where the printer is operating should be capable of dissipating 1.0 kw (3412 Btu or 0.28 ton U.S. refrigeration) of heat or equivalent to temperature requirements. Ensure that any air conditioning ducting does not vent directly onto the 3D printer system. Its is recommended to place the machine in a room that has (4) air turnover cycles per hour. Humidity Humidity should be maintained at 30 to 70% RH. Lighting The 3D printer system is equipped with its own internal light build chamber, and back lit operating panel control with display. Normal area lighting is necessary for operation and service of this system. Indoor lighting such as fluorescent or LED is the best lighting for the system. Do not place the printer next to a window that receives partial or direct sunlight. Vibration and Shock The printer consists of many precision mechanical and sensing systems that are sensitive to vibration during the build process. To maximize the quality and accuracy of the build, it is required that the unit not be near heavy machinery or any source causing high vibration or shock (i.e. exterior walls near train tracks or airports). Location Do not place the printer next to a window that receives partial or direct sunlight. Noise < 65 dba estimated (at medium fan setting)
14 Thank You 3D Systems is confident that you will be very satisfied with the purchase of your ProJet MJP 2500 Professional Printing System. Enjoy the ability to produce high quality parts from your 3-D digital data. We are dedicated to developing a relationship that extends beyond the terms of the sale. Please take the time to contact 3D Systems with questions, comments or suggestions about your ProJet MJP 2500 Professional Printing System, or other products or services. 3D Systems strives for higher quality, better products, and comprehensive services to benefit our customers.
15 3D Printer System Advance Preparation Checklist NOTE: Unless governed by prior arrangement, 3D Systems is not responsible for loading the ProJet MJP 2500 client software on the user s workstation(s). Thus, BEFORE THE 3D PRINTER SYSTEM ARRIVES, ensure that your workstation is capable of supporting the requirements of both the client software and communication with the printer via your network. Review this list with a network administrator, IT department, facilities manager or other responsible person within your organization. Complete and place a check mark next to each item. Once everything is complete, photocopy this page, and fax it to the number checked or provided on the last page of this document. If no number is provided or relevant, then fax to (U.S.A). Please complete the following (if making a copy to fill in, please print): Company Name: Telephone (with area code) Contact (Print full name): Date faxed: Please place a check in each box once that item is complete. Final installation site selected. The intended physical location for each ProJet 2500 Professional Printing System(s) should be selected in advance, and checked for adherence to the guidelines set out in this guide. If required by the shipper, a method of removing the crate from the shipper s truck has been arranged (forklift is required) and is available to transfer the crate(s) to the de-crating location. Operating system and workstation configurations are compatible and meet the minimum requirements as stated in the Client Workstation Requirements section. NETWORK CONNECTION IS INSTALLED. An RJ45 (UTP, female connection jack) Ethernet network connection for EACH 3D printer system that is to be installed at the delivery site must be installed, tested and functioning. TCP/IP is installed and enabled. DCHP or Static IP Dedicated material storage space selected. Material disposal information in place according to local regulations. Static IP address(es) has/have been allocated for each 3D printer system ordered. A permanent IP address on the network is assigned (presumably by a Network Administrator) to each 3D printer system that is to be connected to the network. Write IP address here: Test each IP address by pinging it, or by temporarily connecting a network resource (such as a workstation or a 3D printer system) and pinging from another workstation on the network. Dedicated line, with a surge-and-spike-protected electrical power circuit for each 3D printer system, meeting one of the following specifications (Place check mark beside the appropriate specification: 115 VAC, 50/60 Hz (dedicated 20 amp breaker) 230 VAC 50/60 Hz (dedicated 15 amp breaker)
16 Provide un-interruptable power (active battery back-up) Before the printer is installed into this facility, we acknowledge that the installation site complies with the specifications stated in the ProJet 2500 Facility Requirements Guide. Once the printer is installed, we agree not to alter any of the required specifications listed in this manual without consulting with a 3D Systems Customer Service Representative or certified partner. If alterations are made without consulting 3D Systems, it may void the system s warranty. Customer Signature: Date: Please return a copy of the check list by FAXING it to the appropriate fax number provided in Contacts.
17 Contacting 3D Systems The first point of contact should be your Customer ResellerCertified Partner Attached below is your partner information. ACCOUNT REPRESENTATIVES Place Business Card here and staple to document. STAPLE CARD HERE If you should need to contact 3D Systems headquarters: 3D Systems Corporation 333 Three D Systems Circle Rock Hill, SC Toll-Free Number: (800) Phone Number: (803) Web: more info@3d systems.com For Customer Support: Region Telephone North America (800) DWW-MJM Customer Support@3dsystems.com Europe +49 (0) For localized service or support, contact the appropriate 3D Systems regional facilities listed below: Region Telephone France Fax Number hotline.fr@3dsystems.com Germany hotline.de@3dsystems.com Hong Kong asian.info@3dsystems.com Italy Marketing.IT@3dsystems.com Japan japan.info@3dsystems.com Portugal Spain
18 UK Contact the following Account Representative: Name: Address: Tel: Fax: Returning the Advance Preparation Checklist? Return the completed checklist via the method chosen below: Fax to the Account Representative s fax number (above): Fax to the office fax number (see above) Fax or mail to:
19 Limitation of Liability 3D Systems is not, in any event, liable for any damages, including lost profits, cost of cover, or other special, incidental, consequential, or indirect damages arising from the use of this document, however caused and on any theory of liability. This limitation will apply even if 3D Systems or an certified partner or representative has been otherwise advised of the possibility of such damage. This document, in whole or in part, may be changed or modified at any time at the sole discretion of 3D Systems, without notice.
20
E-Series Installing E-Series U Cabinet
E-Series Installing E-Series 3040 40U Cabinet September 2018 215-13048_A0 doccomments@netapp.com Table of Contents 3 Contents Overview and specifications... 4 Cabinet features... 4 Power requirements
More informationApplied Biosystems QuantStudio 12K Flex Real-Time PCR System
USER GUIDE Applied Biosystems QuantStudio 12K Flex Real-Time PCR System SITE PREPARATION Publication Part Number 4470654 Rev. B Revision Date 5 May 2012 This guide contains the information needed to prepare
More informationPre-Installation Guide and Checklist Fast T-Jet Blazer
Pre-Installation Guide and Checklist Fast T-Jet Blazer April 2008 Version 2 3 Fast T-Jet Blazer Pre-Installation Guide and Checklist The material in this Guide is believed to be accurate and complete with
More informationJ60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
J60 Lithium Ion UPS 350VA Model User & Installation Manual www.xpcc.com 2018. All rights reserved. (Rev 5/24/18) Table of Contents Package Contents...3 Product Introduction...3 Product Overview...3 Installation
More informationCRON HDI-920 Site Planning. Customer Responsibilities
Customer Responsibilities CRON HDI-920 Site Planning You are responsible for providing the following items below to help ensure a trouble free installation. Adequate delivery access (i.e. Company Loading
More informationC60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
For more information, visit www.247technology.com/on-line-ups/c60-standby-ups C60 Standby UPS 800VA Models User & Installation Manual 2015. All rights reserved. (Rev 6/23/15) Table of Contents Package
More informationSite Preparation Guide for CX3-Series Storage Systems in a 40U-C Cabinet
Site Preparation Guide for CX3-Series Storage Systems in a 40U-C Cabinet P/N 300-003-846 REV A02 Tools Required Scissors Mechanical Lift OR Pallet Jack Copyright 2006-2007 EMC Corporation. All rights reserved.
More informationSite Preparation Guide. Objet500/350 3D Printing System. DOC Rev. E
Site Preparation Guide Objet500/350 3D Printing System DOC-07023 Rev. E Copyright Copyright 2018 Stratasys Ltd. All rights reserved. This documentation contains proprietary information of Stratasys Ltd.
More informationSite Preparation Guide. Objet260 3D Printing System. DOC Rev. E
Site Preparation Guide Objet260 3D Printing System DOC-37011 Rev. E Copyright Copyright 2017 Stratasys Ltd. All rights reserved. This documentation contains proprietary information of Stratasys Ltd. This
More informationTable of contents. 1. Introduction
2 Year Warranty Table of contents 1. Introduction 1-1. Transportation 1-2. Preliminary steps 1-3. Initial setup 1-4. Important safety instructions 1-5. Maintenance, service and faults 2. Operation 2.1
More informationSite Preparation Guide. Stratasys J750 3D Printing System. DOC Rev. D1
Site Preparation Guide Stratasys J750 3D Printing System DOC-08015 Rev. D1 Copyright Copyright 2016 Stratasys Ltd. All rights reserved. This documentation contains proprietary information of Stratasys
More informationPre-installation Manual CONCEPT 301 D/401 D/501 D
Pre-installation Manual CONCEPT 301 D/401 D/501 D Pre-installation Manual CONCEPT 301 D/401 D/501 D Concept 301 D T11416 Edition BA, January 2015 This book has part No 10077155 0-2 This manual is published
More informationGerber. Scientific Products. Dear Gerber Sabre Customer:
Gerber Scientific Products 151 Batson Drive, Manchester, CT 06040 (860) 643-1515 Dear Gerber Sabre Customer: Thank you for purchasing the Sabre, Gerber Scientific Products advanced, high-speed, three-dimensional
More informationSite Preparation Guide. Eden260VS 3D Printing System. DOC Rev. H
Site Preparation Guide Eden260VS 3D Printing System DOC-09669 Rev. H Copyright Copyright 2018 Stratasys Ltd. All rights reserved. This documentation contains proprietary information of Stratasys Ltd. This
More informationSaphyr System Safety Guide for Saphyr P/N 60325
Saphyr System Safety Guide for Saphyr P/N 60325 Document Number: 30253 Document Revision: A For Research Use Only. Not for use in diagnostic procedures. Copyright 2019 Bionano Genomics Inc. All Rights
More informationGerber M Series Site Requirements
Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick
More informationRapID Raw Materials Verification System
RapID Raw Materials Verification System Pre-Installation Guide NOTICE: This document contains references to Cobalt or Cobalt Light Systems. Please note that Cobalt Light Systems was purchased by Agilent
More information! CAUTION: Read and follow these instructions.
OmniLog SAFETY AND INSTALLATION INSTRUCTIONS! CAUTION: Read and follow these instructions. Avoid Contact with Hazardous Live Parts WARNING: Risk of electrical shock. Refer servicing to qualified personnel.
More informationAPC Step-Down Transformer. Models: AP9626, AP9627, and AP9628
User Manual English APC Step-Down Transformer Models: AP9626, AP9627, and AP9628 990-7820F 06/2006 Introduction Introduction The APC step-down transformers are used to convert a higher input voltage (208-200
More informationWenger Corporation 2011 Printed in USA 02/11 Part #185A462-01
User Instructions Diva Air Transporter contents Introduction.......................................2 General......................................2 Manufacturer.................................2 European
More informationGerber Scientific Products
Page 1 of 9 Sabre Series Router Pre-Installation Checklist Gerber FastFact # 5003 Supplied by: Gerber Service Last Modified: June 28, 2012 Summary: This document provides the Pre-Installation for your
More informationTeraFrame HD Cabinet System Supplemental Installation Guide
TeraFrame HD Cabinet System Supplemental Installation Guide 800-834-4969 techsupport@chatsworth.com www.chatsworth.com 2010 Chatsworth Products, Inc. All rights reserved. CPI, TeraFrame and MegaFrame are
More informationMaintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual
Maintenance Bypass Breaker Cabinet 90881 Series Configuration 5 Installation and Operation Manual 03/13/2012 2 755-00084-C5 R03 Copyright 2012 C&C Power, Inc. All rights reserved. C&C Power, Inc. 395 Mission
More informationPre-Installation Guide
Pre-Installation Guide PlateWriter 2000 InterPlater 85/135 HD Pre-Installation Guide PlateWriter TM 2000 0-2 2007 Glunz & Jensen A/S. All rights reserved. PlateWriter TM 2000 Pre-Installation Guide Part
More informationAgilent Technologies 7620-AS Sample Changer Site Preparation Checklist Hardware Site Preparation Specification
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation
More informationRENA XPS-3000 Base. User Guide. SC2000 Media Transport System
SC2000 Media Transport System User Guide Please refer to your PS-2000 User Guide for information on the print system that may be attached to this base. NOTE: The SC2000 is also available in a stand-alone
More informationXSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual
XSTi Standby UPS 400VA, 600VA, 800VA Models User & Installation Manual www.xpcc.com 2015. All rights reserved. (Rev 12/14/15) Table of Contents Package Contents... 3 Product Introduction... 3 Product Overview...
More informationMaintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual
Maintenance Bypass Breaker Cabinet 90881 Series Configuration 2 Installation and Operation Manual 03/13/2012 2 755-00084-C2 R03 Copyright 2012 C&C Power, Inc. All rights reserved. C&C Power, Inc. 395 Mission
More informationAgilent 16047D Test Fixture
Agilent 16047D Test Fixture Operation and Service Manual Third Edition Agilent Technologies Japan, Ltd. Agilent PN 16047-90300 May 2000 Printed in Japan Notices The information contained in this document
More informationSby SR Instruments, Inc.
Part No.: MAN947IFS_170629 Page 1 of 12 Sby SR Instruments, Inc. SRV947IFS REMOTE DISPLAY PLATFORM SCALE Operating and Service Manual Part No.: MAN947IFS_170629 Page 2 of 12 TABLE OF CONTENTS TABLE OF
More informationPOWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL
POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL Copyright: November 20, 2018 Revised: Serial No. Gripnail Corporation An Employee Owned Company 97 Dexter Road East Providence, Rhode Island 02914-2045
More informationInstallation and Operation Manual
Installation and Operation Manual Maintenance Bypass Panel Model: SU2030KMBP Tripp Lite follows a policy of continuous improvement. Product specifications are subject to change without notice. 1111 West
More informationSite Preparation Guide. Scodix Ultra Press and Scodix Ultra-Pro Press and Scodix Ultra Foil Station
Site Preparation Guide Scodix Ultra Press and Scodix Ultra-Pro Press and Scodix Ultra Foil Station Important Notice Copyright 2012-2015 Scodix Ltd. All rights reserved. All product names are trademarks
More informationProJet D Professional Printer. Facility Requirements Guide. Original Instructions. Rev. D, P/N 40-D096
ProJet 7000 3D Professional Printer Facility Requirements Guide Original Instructions Rev. D, P/N 40-D096 1. ProJet 7000 Facility Requirements Guide.......................................................................
More informationPre-installation Manual. Plate Processor 68/85 Thermal
Pre-installation Manual Plate Processor 68/85 Thermal Pre-installation Manual Plate Processor 68/85 Thermal T1965 Edition DC, October 2011 Part No 51280 68/85 PLATE PROCESSOR INTRODUCTION RESERVATIONS
More informationSymmetra PX kw 208 V. Receiving and Unpacking 08/2015.
Symmetra PX 10 40 kw 208 V Receiving and Unpacking 08/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred
More informationProJet D Professional Printer. Facility Requirements Guide. Original Instructions. Rev. C, P/N 40-D069
ProJet 6000 3D Professional Printer Facility Requirements Guide Original Instructions Rev. C, P/N 40-D069 1. Table of Contents............................................................................................
More informationAgilent 16048D Test Leads
Agilent 16048D Test Leads Operation and Service Manual Fourth Edition Agilent Technologies Japan, Ltd. Agilent PN 16048-90031 May 2000 Printed in Japan Notices The information contained in this document
More informationTRS100 Rapid Assay System Pre-Installation Guide
TRS100 Rapid Assay System Pre-Installation Guide NOTICE: This document contains references to Cobalt or Cobalt Light Systems. Please note that Cobalt Light Systems was purchased by Agilent in July 2017.
More informationSite Preparation Guide for
Site Preparation Guide for Scodix S52 / S74 / S75 Presses and Scodix Rainbow Station Scodix S52 / S75 Pro Press Scodix S74 Pro Press Scodix Rainbow Station Important Notice Copyright 2010 2014 Scodix Ltd.
More informationLatex 600 and Scitex LX printer family. Site preparation guide
Latex 600 and Scitex LX printer family guide 2010 Hewlett-Packard Development Company, L.P. 2nd edition Legal notices The information contained herein is subject to change without notice. The only warranties
More informationKeysight 16380C Capacitance Standard Set
Keysight 16380C Capacitance Standard Set Operating Note Notices The information contained in this document is subject to change without notice. This document contains proprietary information that is
More informationAgilent 16048B Test Leads Operating Note Third Edition Agilent Part No May 2000
Agilent 16048B Test Leads Operating Note Third Edition Agilent Part No. 16048-90012 May 2000 Printed in Japan Notices The information contained in this document is subject to change without notice. This
More informationXN24 for Package Production. Site Preparation Guide XN24
Site Preparation Guide 10-2014 XN24 Contents 1. Preface... 4 2. Change record...5 3. Introduction...6 3.1 Welcome...6 3.2 About Installation...6 4. Responsibilities... 4.1 Esko Responsibilities... 4.2
More informationUser Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000
Table of Contents Network Pro Series Tower and Rack-Mount Convertible UPS User Manual 1 Introduction ------------------------------------------------------------------------------------2 2 IMPORTANT SAFETY
More informationModel 5200 Cargo Lift Installation and Operation Manual
Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household
More informationOperation and Service Manual
Agilent 16092A Test Fixture Operation and Service Manual Third Edition Agilent Part No. 16092-90010 February 2000 Printed in Japan Notices The information contained in this document is subject to change
More informationTube Revolver. Catalog # & Operation Manual User Manual
Tube Revolver Catalog #88881001 & 88881002 Operation Manual 9240-11-021 User Manual Preface Important Read this instruction manual. Failure to read, understand and follow the instructions in this manual
More informationFPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units
FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units OFFICE MODULE. BOH ENVIRONMENTAL LLC 14520 Avion Parkway, Suite 220 Chantilly, Va.
More informationXBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.
XBDM-HW63 63A Model User & Installation Manual www.xpcc.com 2016. All rights reserved. (Rev 3/02/16) Table of Contents Introduction...3 Product Overview... 3 Installation and Operation...4 Inspection...4
More informationWARRANTY AND SERVICE POLICY
WARRANTY AND SERVICE POLICY Version 2.2.1 (English) Valid for all HARDATA.TV models: HARDATA PLAYOUT series, HARDATA SMART series, HARDATA SMART FLOW series, HARDATA INGEST series, HARDATA OFFICE series
More informationMODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2
FALCON ELECTRIC INC. OWNER S MANUAL SG Series Maintenance Bypass Option 1KVA 3KVA MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2 OM48030 Rev. B 01/17/03 FALCON Electric Inc., 5106 Azusa Canyon Road,
More information42U SmartRack White Standard-Depth Rack Enclosure Cabinet with doors, side panels & shock pallet packaging
42U SmartRack White Standard-Depth Rack Enclosure Cabinet with doors, side panels & shock pallet packaging MODEL NUMBER: SR42UWSP1 Description 42U White SmartRack Enclosure ships mounted on a special pallet
More informationModel 5000 Cargo Lift Installation and Operations Manual
Model 5000 Cargo Lift Installation and Operations Manual Congratulations on the purchase of your new SpaceLift Products 5000 cargo lift system. Expect to receive many years of reliable service moving household
More informationElveflow Flow Reader
Elveflow Flow Reader USER GUIDE October 2014 READ THIS MANUAL CAREFULLY BEFORE USING THE INSTRUMENT This manual must be read by any person who is or will be responsible for using, maintaining or repairing
More informationAssembly Instructions Legacy Basic Acoustical Shell
Assembly Instructions Legacy Basic Acoustical Shell Contents Important User Information...........................2 Safety Precautions.................................3 Required Tools.....................................3
More informationDUST FREE ACTIVE Total Home Air Purification
DUST FREE ACTIVE Total Home Air Purification Installation & Operation Manual This manual covers the following models: DF ACTIVE 6" - #13070 DF ACTIVE 12" - #13071 GENERAL This device is designed to be
More informationLow-profile, 11U high cabinets hold networking equipment, servers, and phone equipment.
RM140A-R3 RM140A-M-R3 RM145A-R3 RM145A-M-R3 Small Office/Home Office (SOHO) Cabinets Low-profile, 11U high cabinets hold networking equipment, servers, and phone equipment. Fit under most desktops in the
More informationLiebert NXL Power-Tie Controls
AC Power For Business-Critical Continuity Liebert NXL Power-Tie Controls and Maintenance Manual CONTACTING EMERSON NETWORK POWER FOR SUPPORT Contact Emerson Network Power Liebert Services for information
More informationXPM 2. Reflow Soldering / Curing Systems. Site Preparation & Installation
XPM 2 Reflow Soldering / Curing Systems Site Preparation & Installation Site Preparation & Installation 1 Revision Date: May 2004 Table of Contents SITE PREPARATION CHECKLIST 3 ROOM PLANNING 4 Oven Clearances
More informationModel E100 Gauss Meter
Model E100 Gauss Meter 2 Table of Contents 1 INTRODUCTION... 3 1.1 The E100 Features:... 3 1.2 The E100 Applications... 3 2 SAFETY SUMMARY... 4 3 COMPLIANCE STATEMENTS... 5 4 PRODUCT CONTENTS AND INSPECTION...
More informationGerber CAT UV. Site Requirements, Operating Performance Requirements and Warranty Limitations
Gerber CAT UV Site Requirements, Operating Performance Requirements and Warranty Limitations The information in this document is extremely important for you and us, as it specifies the requirements needed
More informationAnyvib Vibration Test Chambers
Anyvib Vibration Test Chambers WHY ANYVIB? Because anyvib is the easiest way to combine any kind of shaker with an environmental test chamber. anyvib is a new family of climatic chambers that can be interfaced
More informationTEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION. SPECIFICATION NO. TxDOT DATED: JUNE 2007 MES Class Code:
TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION SPECIFICATION NO. MES Class Code: 050000 THERMAL PROPERTY ANALYZER PUBLICATION This specification is a product of the Texas Department of Transportation
More informationVWR Zero Air Generator Models , Installation, Operation, and Maintenance Manual. Bulletin TI-ZAG3500-L1466
VWR Zero Air Generator Models 26000-020, 26000-022 Bulletin TI-ZAG3500-L1466 Installation, Operation, and Maintenance Manual Bulletin TI-ZAG3500-L1466 VWR Model 26000 Zero Air Generators Warranty United
More informationMinuteman Series. User's Manual
Minuteman Series User's Manual CONTENTS PAGE 1. Introduction..1 2. Receiving Inspection. 1 3. Warranty Registration.1 4. Safety Instruction.1 5. Selection of UPS Location.2 6. Use of External Battery Packs
More information8000 / Facility Requirements Guide. Title. Preparing Your Facility to Install the ipro SLA Center.
8000 / 9000 Facility Requirements Guide Preparing Your Facility to Install the ipro SLA Center www.3dsystems.com Title Copyright 2008-2009 by 3D Systems Corporation. All rights reserved. SLA, Accura and
More informationPMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00
PMA 31-G English 1 Information about the documentation 1.1 About this documentation Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and
More informationInstallation, Operation & Maintenance Manual
Original Instructions Installation, Operation & Maintenance Manual Sentry IC Indexing Cabinet Automatic Sampling Accessories S-AS-IOM-00462-2 11-17 Do not install, maintain, or operate this equipment without
More informationMNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1
Artwork and Signature File for: MAN-01120, MNL, SEL DIMENSIONS, SITE PLANNING GUIDE Artwork consists of: Thirty-Six (36) 8 ½ inch x 11 inch sheet(s) attached. REV AUTHORED BY DATE A.TAMBASCIO 01/20/10
More informationPalletPal Low Profile Disc Turntable
OWNER S MANUAL PalletPal Low Profile Disc Turntable Model # Serial # Date placed in Service SOUTHWORTH PRODUCTS CORP P.O. Box 1380 Portland, ME 04104-1380 Telephone: (207) 878-0700 or (800) 743-1000 Fax:
More informationMOBILE COLUMN LIFT ST ST Superior flexible solutions with an 8.5 ton or 10.0 ton lifting capacity STERTIL SUPERIOR SOLUTIONS
MOBILE COLUMN LIFT ST 1085 - ST 1100 Superior flexible solutions with an 8.5 ton or 10.0 ton lifting capacity STERTIL SUPERIOR SOLUTIONS Superior Solutions The Stertil Group provides customised and technically
More informationSelfCheck System R-Series. Site Planning Guide
SelfCheck System R-Series Site Planning Guide Copyright 2006 2007, 3M. All rights reserved. SelfCheck System R-Series Site Planning Guide 78 8129 2082 1 Rev. C 3M, Tattle-Tape, and SelfCheck are trademarks
More informationAgilent 16034E Test Fixture
Agilent 16034E Test Fixture Operation and Service Manual Third Edition Agilent PN 16034-90041 December 1999 Printed in: Japan Notices The information contained in this document is subject to change without
More informationAgilent 7696A Sample Prep WorkBench
Agilent 7696A Sample Prep WorkBench Site Preparation Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual may be reproduced in any form or by any means (including electronic
More information3601 E. 34th St. Tucson, AZ USA Tel Fax Web:
Equipment Type: Model: Electrical Requirements: Frequency: Manual Revision Date: Air Flow Sound Level Fume Hood FUME HOOD 110V 60 Hz February 15, 2018 1175-1470 cfm 65 dba Contents Warranty PAGE ii 1.0
More informationAnnex A. Statement of Requirements. Supply of IT Computer Hardware and Software to UNICEF
Annex A Annex A Statement of Requirements Supply of IT Computer Hardware and Software to UNICEF Introduction: UNICEF is the agency of the United Nations mandated to advocate for the protection of children's
More informationInstallation. Smart-UPS VT in Parallel kva 380/400/415 V 208/220 V 200/208 V
Installation Smart-UPS VT in Parallel 10-40 kva 380/400/415 V 208/220 V 200/208 V Contents Safety... 1 IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS.............................. 1 Prepare for
More informationSymmetra PX 160 Classic Battery Cabinet
Symmetra PX 160 Classic Battery Cabinet Receiving and Unpacking 04/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries
More informationRack Power Distribution Unit AP7562, AP7563, AP7564 General Information
Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information Description This booklet provides information on installing and operating the Rack Power Distribution Units (PDUs) AP7562, AP7563,
More informationGelovit 200 en English
Gelovit 200 en English Translation of the original instructions BA 85 981 / 02 334.00001... en Gelovit 200 This unit documentation is part of the unit and must be enclosed when selling or passing on the
More informationUser s Manual. Chart Projector GCP-7000
User s Manual Chart Projector GCP-7000 ------------------------------------------------------------------------ Chart Projector GCP-7000 1 IMPORTANT NOTICE This product may malfunction due to electromagnetic
More informationTR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027
TR1 TR2 Transformer / Relay Adapter Installation Manual Rev 1.1 Feb. 22, 2016 Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027 Tel: (615) 819-0800 Fax: (615) 819-0801 www.deklintech.com
More informationInstallation Manual. MONISAFE 400A System V ( ) Nautilus Hyosung, Inc. All Rights Reserved.
MONISAFE 400A System V01.00.00 (2013.11.08) Nautilus Hyosung, Inc. All Rights Reserved. Revision History MONISAFE 400A System No. Version Date Description of Change Chapter 1 V01.00.00 2013/11/08 New Publication
More informationhp hardware support onsite global next day response
hp care pack hp hardware support onsite technical data hp hardware support onsite global next day response service overview benefits to you service highlights HP s global next day response service provides
More informationEXPRESS5800/1080Xd. Installation Procedures
EXPRESS5800/1080Xd () Installation Procedures Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials, is the valuable property
More informationThe Ton-Tel Weighbridge
The Ton-Tel Weighbridge Plug-and-Weigh Technology Built to last in a tough environment Proven reliability, lower total cost of ownership. Digital Load Cell weight sensors sealed to IP68. Plug-and-Weigh
More informationFacility Requirements Guide Viper Pro SLA System Preparing Your Facility to Install the Viper Pro SLA System
Facility Requirements Guide Viper Pro SLA System Preparing Your Facility to Install the Viper Pro SLA System IM N ARY Table of Contents Introduction... 1 Site Selection - Viper Pro SLA System...3 Site
More informationModel 5200 Cargo Lift Installation and Operation Manual
Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household
More informationBest Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)
Best Selection for Your Business Electronic Pricing Scale User s Manual (Model: TP-31) CATALOG 1. Foreword... 2 1.1. Introductions... 2 1.2. Main functions and features... 2 1.3. Specification... 2 1.4.
More informationLatex 3000 Printer series. Site Preparation Checklist
Latex 3000 Printer series Site Preparation Checklist 2015, 2017 HP Development Company, L.P. 3 Legal notices The information contained herein is subject to change without notice. The only warranties for
More informationCustomer Responsibilities
Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation of your Agilent ICP-OES, please refer to this site preparation checklist. Correct site
More informationPD662 LOOP-POWERED METER
PD662 LOOP-POWERED METER 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Programmable Noise Filter Loop-Powered Backlight Option 1.7 Volt Drop without Backlight
More informationT1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features
INSTRUCTION SHEET T1000 Transformer for Magnetic-Field Susceptibility Testing Features Up to 100 A RMS secondary current Exceeds AF Magnetic Field test requirements of DO 160 Section 19 and Boeing D6-16050-5
More informationALTRONIC RESEARCH, INC.
ALTRONIC RESEARCH, INC. P.O. BOX 249 YELLVILLE, ARKANSAS 72687-0249 U.S.A. CALORIMETRY MODEL 3500 TABLE OF CONTENTS CALORIMETRY MODEL 3500 SECTION PAGE Warranty... 3 Introduction... 4 I. Description and
More informationEPS Receiving and Unpacking 06/
EPS 8000 555 1125 kva Receiving and Unpacking 06/2015 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred
More informationWeighSouth. WBT Toploader Balance
WeighSouth WBT Toploader Balance Part List Balance...1 pc. Weighing Pan...1 pc. Draft Shield (Model WBT-100 only)...1 pc. Calibration Weight... WBT-100, WBT-602 AC Adapter...1 pc. Instruction Manual...1
More informationDandy Leveler UDLV-150 & UDLV-500 (New Style)
Owner s Manual Dandy Leveler UDLV-150 & UDLV-500 (New Style) Model # Serial # Southworth Products Corp P.O. Box 1380/Portland, Maine 04104-1380 Phone 800-743-1000 FAX 207-797-4734 www.southworthproducts.com
More informationOcé Arizona 250 GT. Site Preparation Guide. Revision B September, 2007 Part Number:
Océ Arizona 250 GT Site Preparation Guide Revision B September, 2007 Part Number: 3010105569 Océ Display Graphics Systems 2007 All Rights Reserved Table of Contents Preface Copyright...iii Document Summary...iii
More information