Vertical access challenges? The SHU fits.

Size: px
Start display at page:

Download "Vertical access challenges? The SHU fits."

Transcription

1 VERTICAL ACCESS PLATFORM ATTACHMENT No more using ladders or standing on mid-rails, buckets and planks on the platform. SHU facilitates safe, OSHA compliant access to narrow spaces, for example ceiling grids and joists. SHU safely increases working height and can be used with the rails up or lowered with our fall protection system. Step into our SHU. NOW AVAILABLE ON GENIE SCISSORS Vertical access challenges? The SHU fits. FEATURES SAFE ANSI A92.6 Compliant CSA B354.2 Compliant OSHA Compliant Fall protection anchorage Safety cutout disables lift operation while on SHU platform when rails are lowered PRODUCTIVE SHU platform adds 20 of height Safe access to narrow areas Reduces the need for ladders Eliminates standing on railings, buckets or planks Provides access to small overhead spaces, for example ceiling grids and joists When needed, rails can be lowered for additional access INNOVATIVE Customer and market driven design in response to real industry challenges Reduces risk of injury Easily replaces existing extension deck Retrofit to 2004 and newer, 30 and 46 wide Genie scissor lifts [414]

2 VERTICAL ACCESS PLATFORM ATTACHMENT NOW AVAILABLE ON GENIE SCISSORS SHU SPECIFICATIONS: 30 WIDE A - Added Height 20 in 0.51 m B - Platform Width 21.5 in 0.55 m C - Platform Length 24.8 in 0.63 m D - Added Length 28.1 in 0.71 m E - Outside Width 27.5 in 0.70 m F - Guardrail Height in 1.00 m G - Mid-Rail Height 18.4 in 0.47 m H - Mid-Rail Height (Scissor) 18.1 in 0.46 m Weight 155 lb kg Scissor Capacity 440 lb kg SHU Capacity 250 lb kg Specifications Subject to Change / Patent Pending F B G A C D H STANDARDS COMPLIANCE ANSI A92.6 CSA B354.2 OSHA Compliant G EASY INSTALLATION Remove existing extension deck and roller bracket assembly Lift and position the SHU onto the top of the scissor platform Insert platform roller wheels and brackets, reinstall roller bracket assembly Secure the SHU to the platform using the provided hardware Connect provided cutout switch to quick connect A E H PATENT PENDING SPEC# sales@manliftmfg.com [414]

3 OPERATION SAFETY GUIDE OPERATION ENABLED OPERATION ENABLED SHU UNLOADED / RAILS UP Drive / lift / lower is enabled to maneuver scissor lift; this is the standard drive position OPERATION ENABLED SHU UNLOADED / RAILS DOWN Drive / lift / lower is enabled to maneuver stowed SHU through narrow areas such as doorways OPERATION DISABLED SHU LOADED / RAILS UP Drive / lift / lower is enabled to allow maneuverability into working position SHU LOADED / RAILS DOWN Drive / lift / lower is disabled for added safety while SHU is loaded and rails are down PATENT PENDING SPEC# sales@manliftmfg.com [414]

4 1 of 2 August 16, 2013 Subject: Attachment of the Man Lift Manufacturing SHU Platform. Subject to the terms and conditions of this letter, Genie Industries Inc. approves the use of Genie Scissors when modified in accordance with Man Lift Manufacturing (MLM) requirements for installation and use of the SHU platform. The machine with the SHU attachment must be used in accordance with the instructions in the Genie Scissor Operator s Manual and MLM SHU Manual. Warning: Failure to comply with all restrictions, instructions and warnings contained in this letter, the Genie Scissor Lift Operators Manual, the Man Lift SHU Operator s manual(s) and decals and the applicable installation, safety or owner s manual could result in death or serious injury. Application Description: This applies only to SHU vertical access platform attachment, a device manufactured by Man Lift Manufacturing and is only applicable to the Genie models listed on the installation instructions provided by Man Lift Manufacturing. Owner/Employer/User/Operator Requirements: 1) No modification to the Genie equipment, or use of it outside the proposed application, is permitted outside the approval criteria contained hereinafter. 2) A copy of this letter must accompany the operators manual at all times in the weather resistant storage compartment located on the equipment at the job-site where this modification/application is approved and authorized by the user/employer. 3) Operators must be trained and qualified how to safely operate the modified equipment, or use it in the proposed application, and be familiar with the specific model of Genie equipment as follows: a) Be familiar, and comply, with the equipment operating and safety manuals. b) Understand all control functions, decals and warnings. c) Be aware of and understand all safety devices specific to the equipment being used. d) Be instructed regarding the specific hazards associated with using the Genie equipment, in its modified state, or in the proposed application, and utilize all means, including those provided by the user/employer, to avoid them. 4) The user/employer and the operator shall comply with all applicable jobsite, local, state, provincial, or federal rules, regulations, and standards related to the use of the equipment and its modification. 5) The Genie equipment must be in proper working condition and configuration. Additional Requirements: Installation and use of the SHU must comply with requirements provided by Man Lift Manufacturing NE 76th Street Redmond, WA USA Phone:

5 2 of 2 In consideration for Genie s authorization herein, the equipment owner hereby agrees to indemnify and hold harmless Genie Industries Inc. and its parent and affiliated companies against any and all liability, claims, suits, losses, costs and legal fees caused by, arising out of, or resulting from the approved modification/application of the Genie equipment; any negligent act in the operation of the equipment by the owner, user and/or operator; the failure to comply with the criteria set forth in this letter related to the modification/application; the design, manufacture and installation of any modification; the safety rules and operating instructions in the Operator's Manual; the design and placement of any safety decals; the operation of the equipment by the owner, user and/or operator; and any negligent act or omission related to the equipment, its use or its modification. BY PROCEEDING WITH THE MODIFICATION/APPLICATION AUTHORIZED HEREIN, YOU AGREE TO THE CONTENTS OF THIS LETTER AND ITS CONDITIONS. IF YOU DO NOT AGREE, DO NOT PROCEED WITH THE PROPOSED MODIFICATION/APPLICATION NE 76th Street Redmond, WA USA Phone:

6 SHU 30 ORDER INFORMATION Order Date Requested Delivery Date Quantity Unit Price Total Price P.O. Number Sales Representative CUSTOMER / BILLING INFORMATION Contact Name Company Name Street Address Street Address Line 2 City State Zip Code Phone Number Address SHIPPING INFORMATION Same As Billing Contact Name Company Name Street Address Street Address Line 2 City State Zip Code (check here) Notes: Retrofit to 2004 and newer, 30 wide Genie scissor lifts. You will be contacted by an MLM representative to complete the order and arrange shipping. SHU 32 and SHU 46 available soon. PATENT PENDING FORM#091913

7

8 What s Your Access Challenge? Man Lift Mfg. Co. is a designer and manufacturer of aerial access and material handling solutions. MLM has been providing lift and access equipment for the most unique, hazardous and challenging environments since 2000 and is a reliable partner to leaders in aerospace, commercial aviation, oil and gas, and industrial manufacturing. Our turnkey solutions encompass in house design, manufacturing, testing and certification. All of our solutions fit within our core mission of providing: Safe. Productive. Innovative Access Solutions Manufactured and supported in the USA.

9 SAFE Lift, access and material handling solutions for hazardous locations EX Explosion Proof Electrically Insulated Magnetically Shielded Heat Shielded Cleanroom Safe MSHA Mining Electric Conversion PRODUCTIVE Application specific solutions designed and built to maximize productivity Machinery Carts High Capacity Pedestal Mount Vertical Mast & Tower Modified Platforms Modified Controls INNOVATIVE Advancements in lift, access and material handling technology SHU: Vertical Access Platform Attachment OMNI: Multi-Directional Steering PROXY: Collision Avoidance System XA: Extreme Aircraft Scissor Lift AGV: Automatic Guided Vehicle

10 MAN LIFT MFG. CO S. PENNSYLVANIA AVE. CUDAHY, WI (414) MANLIFTMFG.COM

A suspended load has a dynamic effect on machine stability, so extreme caution should always be exercised when operating with suspended loads.

A suspended load has a dynamic effect on machine stability, so extreme caution should always be exercised when operating with suspended loads. Arrow Material Handling CE60 TH Truss Boom Approval page 1 of 13 March 1 st, 2016 Subject: The use of an Arrow Material Handling Extendable Truss Boom Model CE60 TH on the following Genie telehandler models;

More information

BOOM-SUPPORTED ELEVATING WORK PLATFORM PROGRAM

BOOM-SUPPORTED ELEVATING WORK PLATFORM PROGRAM Page: 1 of 7 1.0 PURPOSE and APPLICABILITY 1.1 It is the policy of the University of Pennsylvania in coordination with the Office of Environmental Health and Radiation Safety to provide the University

More information

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY AERIAL WORK PLATFORM POLICY 09/06/17 Last Revision

FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY AERIAL WORK PLATFORM POLICY 09/06/17 Last Revision FACILITIES MANAGEMENT OFFICE OF ENVIRONMENTAL HEALTH AND SAFETY AERIAL WORK PLATFORM POLICY 09/06/17 Last Revision 1. Intent This program has been developed to reduce the risk of physical injury or property

More information

TECH TIPS. Booms/Scissors. Service Call: Platform repair instructions of steel guard rails on Terex/Genie Aerial Work Platforms and Scissors

TECH TIPS. Booms/Scissors. Service Call: Platform repair instructions of steel guard rails on Terex/Genie Aerial Work Platforms and Scissors TECH TIPS Service Call: Platform repair instructions of steel guard rails on Terex/Genie Aerial Work Platforms and Scissors Tools Needed: See attached document for required tools Model: Booms/Scissors

More information

Effective Date: 10-January Table of Contents

Effective Date: 10-January Table of Contents Version: 3 Page: 1 of 8 Table of Contents 1.0 Introduction... 2 1.1 Purpose... 2 1.2 Scope... 2 1.3 Definitions... 2 1.4 Responsibilities... 2 Environmental Health and Safety Office (EHSO) and Emory Healthcare

More information

SafeDeck Supported Scaffold System

SafeDeck Supported Scaffold System SafeDeck Supported Scaffold System Table of Contents Origination 1 Range of Motion 1 Installation Efficiency 2 Third-Party Testimonial 2 SafeDeck Specifications 3 Competent Person 4 Tools Required 4 Components

More information

AERIAL LIFT MANUAL. Environmental Health & Safety. Oklahoma State University

AERIAL LIFT MANUAL. Environmental Health & Safety. Oklahoma State University Environmental Health & Safety Oklahoma State University AERIAL LIFT MANUAL Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu Reviewed

More information

PORTABLE LADDER SAFETY

PORTABLE LADDER SAFETY LADDER AND SCAFFOLD SAFETY PLAN Ladder & Scaffold Safety Falls can result in serious injury or death. Falls from a higher elevation account for approximately 10% of workplace fatalities and 5.2% of nonfatal

More information

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR

INCLINATOR ELEVETTE. Planning Guide. CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR INCLINATOR ELEVETTE Planning Guide CABLE DRUM 1000 lb. (454 Kg) AMERICA S MOST CUSTOMIZABLE ELEVATOR Introduction It started over 90 years ago with a passion to help an ailing friend access his multi-level

More information

Load Handling (Hoisting) Policy

Load Handling (Hoisting) Policy 1.0 PURPOSE This policy is to promote safe load handling (hoisting) practices and reduce the frequency and severity of incidents. The purpose is to protect personnel from injury, the environment from harm,

More information

ASSEMBLY.

ASSEMBLY. ASSEMBLY www.proscaf.com ASSEMBLY SECTION Points to Consider These assembly instructions are generic and may not apply to all applications. If you have questions regarding specific applications contact

More information

1 IMHOFF CUSTOM SERVICES INC. AERIAL LIFT POLICY

1 IMHOFF CUSTOM SERVICES INC. AERIAL LIFT POLICY 1 IMHOFF CUSTOM SERVICES INC. AERIAL LIFT POLICY Purpose and Applicability The purpose of this Program is to ensure that Imhoff Custom Services Inc. employees who operate aerial or scissor lifts have the

More information

Operation Manual. Roof Purlin & Roller Door Locator Attachment Model A-400

Operation Manual. Roof Purlin & Roller Door Locator Attachment Model A-400 Operation Manual Roof Purlin & Roller Door Locator Attachment Model A-400 Serial Numbers A400-1 onwards Page 1 Contents Introduction... 3 Work Area Safety... 4 Tip over Hazard... 4 Dropping Hazard... 4

More information

Safe Work Procedure for installation of

Safe Work Procedure for installation of Safe Work Procedure for installation of external cladding This procedure has been formulated to cover safe systems of work for the installation of external cladding. This instruction will be used to reduce

More information

SAFE WORK PROCEDURE: MOBILE ELEVATED WORK PLATFORMS (MEWP)

SAFE WORK PROCEDURE: MOBILE ELEVATED WORK PLATFORMS (MEWP) Rev: 01 Date: March 2017 Page: 1 of 8 SAFE WORK PROCEDURE: MOBILE ELEVATED WORK PLATFORMS (MEWP) A. OVERVIEW: Safe Work Procedures are crucial to preventing workplace injuries and accidents. Safe Work

More information

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR SERIES MDS-96-BK, SM, DR OWNER S MANUAL Introduction... 1 Bill of Materials... 2 Assembly Instructions. 3 Warranty....12 IMPORTANT NOTES, WARNINGS AND SAFETY INSTRUCTIONS Ensure that all employees understand

More information

EASTERN MICHIGAN U N I V E R S I T Y AERIAL WORK PLATFORMS PROGRAM

EASTERN MICHIGAN U N I V E R S I T Y AERIAL WORK PLATFORMS PROGRAM EASTERN MICHIGAN U N I V E R S I T Y AERIAL WORK PLATFORMS PROGRAM Department of Public Safety Health and Safety Office 1200 Oakwood Ypsilanti, Ml 48197 734.487.0794 January 2007 EASTERN MICHIGAN UNIVERSITY

More information

Product Selection Guide

Product Selection Guide Product Selection Guide Basic Trailer Unloading Mobile Ramp Fixed Position Loading Dock Portable Loading Docks Portable Loading Dock Railcar Unload Implements Utility Vehicles Mobile Loading Dock Specialty

More information

Mechanical Post Lift. Owner s Manual

Mechanical Post Lift. Owner s Manual Table Owner s Manual Model: Serial Number: Date placed in service: Presto ECOA Lifts 50 Commerce Way, Norton, MA 02766 Phone: 800.343.9322 Fax: 888.788.6496 www.prestolifts.com Email: service@prestolifts.com

More information

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR VESTIL MANUFACTURING CORP. 2999 N. Wayne St., Angola, IN 46703 Ph: 260-665-7586 Fax: 260-665-1339 E-mail: sales@vestil.com Website: www.vestil.com SERIES MDS-96-BK, SM, DR OWNER S MANUAL Introduction...

More information

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

Dandy Leveler UDLV-150 & UDLV-500 (New Style) Owner s Manual Dandy Leveler UDLV-150 & UDLV-500 (New Style) Model # Serial # Southworth Products Corp P.O. Box 1380/Portland, Maine 04104-1380 Phone 800-743-1000 FAX 207-797-4734 www.southworthproducts.com

More information

Scissor Lift Safety. Supervisor Manual 29 CFR , 451, 452, 454. Page 0

Scissor Lift Safety. Supervisor Manual 29 CFR , 451, 452, 454. Page 0 Scissor Lift Safety 29 CFR.1926.450, 451, 452, 454 Supervisor Manual Page 0 Table of Contents Purpose... 2 Program Responsibilities... 2 Management... 2 Supervisors... 2 Employees... 2 Definitions... 3

More information

Lenovo 42U 1200mm Deep Racks Product Guide

Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200 mm Deep Static and Dynamic Rack offerings are industry-standard 19-inch server cabinets that are designed for high availability server environments.

More information

Walking & Working Surfaces / Back Safety and Ergonomics

Walking & Working Surfaces / Back Safety and Ergonomics Walking & Working Surfaces / Back Safety and Ergonomics 29 CFR 1910.21-30 29 CFR 1910.66-67 67 29 CFR 1926.450-454 454 29 CFR 1926.1050-1060 1060 Scope Federal regulations cover the rules for the design

More information

AR SCAFFOLDING AR ALUMINUM MOBILE AR STEEL MOBILE

AR SCAFFOLDING AR ALUMINUM MOBILE AR STEEL MOBILE SAFETY RULES and INSTRUCTIONS FOR AR SCAFFOLDING AR ALUMINUM MOBILE AR STEEL MOBILE INTERIOR or EXTERIOR USE ! WARNING! Improper assembly, dismantling or use of Multi-Use Scaffold may result in serious

More information

Educational Course Application

Educational Course Application STATE OF WISCONSIN Department of Safety and Professional Services Educational Course Application Personal information you provide may be used for secondary purposes [Privacy Law, s. 15.04(1)(m)]. Safety

More information

Guardrail Clamping System. Installation Instructions

Guardrail Clamping System. Installation Instructions VersiShield Guardrail Clamping System Installation Instructions WARNING THIS DEVICE SHOULD ONLY BE USED UNDER THE CLOSE SUPERVISION OF AN OSHA CERTIFIED COMPETENT PERSON. The VersiShield Guardrail Clamp

More information

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW WE CARE FIXFAST Providing maximum safety with minimum fuss to workers at height. Our extensive range of safe access products and fall protection systems are designed

More information

(Insert Company Name)

(Insert Company Name) Site Specific Fall Protection Plan for Residential Construction (Insert Company Name) This Fall Protection Plan Is Specific For The Following Project: Location of Job Date Plan Prepared or Modified Plan

More information

CONTRACT PROPOSAL/CONTRACT ACCEPTANCE HIGDON LOOP ROAD BRIDGE

CONTRACT PROPOSAL/CONTRACT ACCEPTANCE HIGDON LOOP ROAD BRIDGE CONTRACT PROPOSAL/CONTRACT ACCEPTANCE PROJECT # 2017-NC-001 For Construction of HIGDON LOOP ROAD BRIDGE located in Nelson County Kentucky 09/2017 REQUEST FOR BIDS HIGDON LOOP ROAD BRIDGE REPLACEMENT Nelson

More information

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2)

Installation Manual. Orion. TL-3 Steel Barrier. VHD (v2) Installation Manual Orion TL-3 Steel Barrier VHD (v2) 300914 Table of Contents Orion Introduction.......... 3 Limitations & Warnings. 4 Before Installation..... 3 System Design & Design Considerations

More information

Having our roots throughout North America gives Nation Ramps clients the flexibility they deserve.

Having our roots throughout North America gives Nation Ramps clients the flexibility they deserve. Having our roots throughout North America gives Nation Ramps clients the flexibility they deserve. Nation Ramps has the capability to deliver our ramps anywhere in North America at some of the most competitive

More information

Loading Dock Buyers Guide

Loading Dock Buyers Guide Loading Dock Buyers Guide Basic Trailer Unloading Mobile Ramp Fixed Position Loading Dock Portable Loading Docks Portable Loading Dock Railcar Unload Implements Utility Vehicles Mobile Loading Dock Specialty

More information

MANDATORY SERVICE BULLETIN SB12-07 *MANDATORY SERVICE BULLETIN* KODIAK. REVISION: 00 DATE: September 26, 2012

MANDATORY SERVICE BULLETIN SB12-07 *MANDATORY SERVICE BULLETIN* KODIAK. REVISION: 00 DATE: September 26, 2012 KODIAK MANDATORY SERVICE BULLETIN SB12-07 NUMBER: SB12-07 REVISION: 00 DATE: September 26, 2012 SUBJECT: EXTERNAL CARGO COMPARTMENT JACK POINT REMOVAL *MANDATORY SERVICE BULLETIN* EFFECTIVITY: KODIAK 100

More information

MUNICIPALITY PERMIT Issued by the City of Holyoke 63 Canal Street, Holyoke, MA Phone (413) FAX (413)

MUNICIPALITY PERMIT Issued by the City of Holyoke 63 Canal Street, Holyoke, MA Phone (413) FAX (413) MUNICIPALITY PERMIT Issued by the City of Holyoke 63 Canal Street, Holyoke, MA 01040 Phone (413) 322-5645 FAX (413) 539-6807 DPW OFFICIAL USE ONLY Permit Number Date Issued Expiration Date (If Applicable)

More information

Having our roots throughout North America gives Nation Ramps clients the flexibility they deserve.

Having our roots throughout North America gives Nation Ramps clients the flexibility they deserve. Having our roots throughout North America gives Nation Ramps clients the flexibility they deserve. Nation Ramps has the capability to deliver our ramps anywhere in North America at some of the most competitive

More information

WORKING AT HEIGHT PROCEDURE

WORKING AT HEIGHT PROCEDURE Page 1 of 8 AL-Yamama Engineering Company HSSE Department (s) WORKING AT HEIGHT PROCEDURE Page 1 of 8 Page 2 of 8 Introduction Work at height is any work activity that is performed where the work is to

More information

PalletPal Low Profile Disc Turntable

PalletPal Low Profile Disc Turntable OWNER S MANUAL PalletPal Low Profile Disc Turntable Model # Serial # Date placed in Service SOUTHWORTH PRODUCTS CORP P.O. Box 1380 Portland, ME 04104-1380 Telephone: (207) 878-0700 or (800) 743-1000 Fax:

More information

SAFE WORK METHOD STATEMENT (SWMS)

SAFE WORK METHOD STATEMENT (SWMS) ABN: 12 345 678 910 ACN: 123 456 789 Address: Your Company Address PH: Your Company Phone E: Your Company Email Web: Your Company Website PROJECT DETAILS: Project: SAFE WORK METHOD STATEMENT (SWMS) Area:

More information

HP 3-7U Quick Deploy Rail System Installation Instructions

HP 3-7U Quick Deploy Rail System Installation Instructions HP 3-7U Quick Deploy Rail System Installation Instructions for HP products Overview This rack hardware kit supports a variety of 3-7U HP products in round-, square-, or threaded-hole racks. Use the legend

More information

Load Handling (Hoisting) Policy

Load Handling (Hoisting) Policy 1.0 PURPOSE This policy is to promote safe load handling (hoisting) practices and reduce the frequency and severity of incidents. The purpose is to protect personnel from injury, the environment from harm,

More information

Nutrient Removing Filtration System

Nutrient Removing Filtration System Nutrient Removing Filtration System Contractor Installation Manual Version 1.0 Suntree Technologies, Inc 798 Clearlake Road, Suite 2 Cocoa, Florida 32922 321.637.7552 www.suntreetech.com info@suntreetech.com

More information

INDUSTRIAL STAIRS. World s Largest Stair Manufacturer

INDUSTRIAL STAIRS. World s Largest Stair Manufacturer INDUSTRIAL STAIRS COMMERCIAL STAIRS PORTABLE STAIRS ARCHITECTURAL STAIRS World s Largest Stair Manufacturer Designed for Work, Built for Safety Mobile Work Platforms & Stairs Access when and where you

More information

INSTRUCTIONS FOR SUBMITTING SMALL CELL FACILITIES USE PERMIT APPLICATION

INSTRUCTIONS FOR SUBMITTING SMALL CELL FACILITIES USE PERMIT APPLICATION INSTRUCTIONS FOR SUBMITTING SMALL CELL FACILITIES USE PERMIT APPLICATION (1) Applicants should review Chapter 917 of the Richfield Codified Ordinances prior to submitting an application. (2) All Small

More information

To Contact PS DOORS:

To Contact PS DOORS: MODELS Stainless Steel (SS) Powder Coat Yellow (PCY) Hot Dipped Galvanized (GAL) TABLE OF CONTENTS PAGE Warranty Information General Paired LSG Information Installing the Support Channels 3 Installing

More information

Document Revision Change Table Revision Number

Document Revision Change Table Revision Number Beaumont Site Procedure No.: BMEHS-002.025 Reviewed: 01/17 Page: 1 of 7 Document Revision Change Table Revision Number Revision Description Revised By Revision Date Rev. 03 Considered as starting document

More information

Phase Shifter. No. SP-LFZ P1/6. 1. Electrical Characteristics (at -40 ~ +85 C) Nominal Characteristics Impedance

Phase Shifter. No. SP-LFZ P1/6. 1. Electrical Characteristics (at -40 ~ +85 C) Nominal Characteristics Impedance P1/6 Phase Shifter 1. Electrical Characteristics (at -40 ~ +85 C) LFP152G5E090F123TEMP 0.48 db max. at +25 C 0. 53 db max. at -40 ~ +85 C 13.0 db min. at 200.00 ~ 400.00 MHz 94.5 ± 5.5 at 2400.00 MHz 90.0

More information

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW

MODULAR ACCESS SYSTEMS PRODUCT OVERVIEW PRODUCT OVERVIEW FIXFAST USA Providing maximum safety with minimum fuss to workers at height. Our extensive range of safe access products and fall protection systems are designed for industrial, commercial

More information

Operator s Manual for Morse Heavy-Duty Kontrol-Karrier with 3-Piece Drum Holder

Operator s Manual for Morse Heavy-Duty Kontrol-Karrier with 3-Piece Drum Holder CONTENTS Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3 Operating Instructions....................

More information

General Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions.

General Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions. General Guidelines It is the user s responsibility to read and follow all instructions. Instructions for Part # WP-48-1000 Keep these instructions with the product at all times and review before each use.

More information

Operating Guidelines

Operating Guidelines Operating Guidelines Application and Fees Vendors are required to complete the Hold Harmless Agreement and Vendor Application. There is no fee required for vendors to participate in the Sampson Farmers

More information

1-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series

1-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series Contents Page Receiving Procedures.................... 1 Warranty............................. 1 Safety Information..................... 1-2 Machine Description................... 3 Operating Instructions....................

More information

Powered Industrial Trucks (Forklift) Program. Elizabeth City State University Office of Environmental Health & Safety

Powered Industrial Trucks (Forklift) Program. Elizabeth City State University Office of Environmental Health & Safety Powered Industrial Trucks (Forklift) Program Elizabeth City State University Office of Environmental Health & Safety I. Purpose In accordance to the provisions of the NC OSHA Powered Industrial Truck Standard

More information

Leveling Foot RB210. Leg Extender RLT66

Leveling Foot RB210. Leg Extender RLT66 Landing for Right & Left Turn R342 ITEMS # 0254049, 0254061, 0254072, 0254076, 0016567, 0254099, 0254110, 0054116, 0254117, 0254126, 0254140, 0254150, 0254156 CUSTOM ACCESS RAMP SYSTEM MODELS # R100, R242,

More information

POOL STEP INSTRUCTIONS (NE1087WH)

POOL STEP INSTRUCTIONS (NE1087WH) POOL STEP INSTRUCTIONS (NE1087WH) 6492 The sequence of the instructions may vary at points depending on the type of step system that you have purchased. If there are different instructions for your system,

More information

OSH5063EP(PRS3607) Workplace and Work Equipment Hazard. Session 9. Working at Height

OSH5063EP(PRS3607) Workplace and Work Equipment Hazard. Session 9. Working at Height OSH5063EP(PRS3607) Workplace and Work Equipment Hazard Session 9 Working at Height 1 Introduction The most common fatal type of accident in construction remains falling from a height 2 Introduction Where

More information

PS-4045 Adjustable-Height Pallet Stand Use and Maintenance Manual

PS-4045 Adjustable-Height Pallet Stand Use and Maintenance Manual Vestil Manufacturing Co. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-339 http://www.vestilmfg.com/ e-mail: sales@vestil.com

More information

INSTALLATION MANUAL ORION BARRIER. NCHRP 350 TL-3 Portable Steel Longitudinal Barrier

INSTALLATION MANUAL ORION BARRIER. NCHRP 350 TL-3 Portable Steel Longitudinal Barrier INSTALLATION MANUAL ORION BARRIER NCHRP 350 TL-3 Portable Steel Longitudinal Barrier INSTALLATION AND MAINTENANCE MANUAL Table of Contents Orion Introduction.......... 3 System Overview..... 3 Before Installation....

More information

PAL SERIES PALLET PULLERS Instruction Manual

PAL SERIES PALLET PULLERS Instruction Manual VESTIL MNUFCTURING CORP. 2999 North Wayne Street, P.O. Box 507, ngola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com PL

More information

Floor Loading Information 30 minutes

Floor Loading Information 30 minutes Date: June 27, 2011 Models and Serial Numbers Affected: S40 : 832 to 16027 S45 : 832 to 16027 Subject: Allowable Hours: Floor Loading Information 30 minutes Issue: Genie Industries has determined that

More information

LIFT-O-FLEX EOT (Manual Rotate & LIFTER USER MANUAL. Electric Expander) We re here for you. PLACE SERIAL NUMBER LABEL HERE. Have Questions?

LIFT-O-FLEX EOT (Manual Rotate & LIFTER USER MANUAL. Electric Expander) We re here for you. PLACE SERIAL NUMBER LABEL HERE. Have Questions? PLACE SERIAL NUMBER LABEL HERE LIFT-O-FLEX EOT (Manual Rotate & Electric Expander) LIFTER USER MANUAL DOCUMENT ID: 01022018 Have Questions? We re here for you. R ON I READ BEFORE YOU BEGIN It is important

More information

COLLECTIVE POSITION ON SAFE REMOVAL OF TEMPORARY BRACES

COLLECTIVE POSITION ON SAFE REMOVAL OF TEMPORARY BRACES COLLECTIVE POSITION ON SAFE REMOVAL OF TEMPORARY BRACES Published by the Tilt-Up Concrete Association Tilt-Up Concrete Association PO Box 204 Mount Vernon, Iowa 52314 (319) 895-6911 www.tilt-up.org COLLECTIVE

More information

Scaffolding Procedures

Scaffolding Procedures Procedures Purpose It is the purpose of this company in issuing these procedures to further ensure a safe workplace based on the following formal, written procedures for scaffold work. Application This

More information

PHASE SHIFTER. No. LFP15CE-01 P1/ Electrical Characteristics (at -40 ~ +85 C) Nominal Characteristics Impedance

PHASE SHIFTER. No. LFP15CE-01 P1/ Electrical Characteristics (at -40 ~ +85 C) Nominal Characteristics Impedance No. LFP15CE-01 P1/12 PHASE SHIFTER 1. Electrical Characteristics (at -40 ~ +85 C) LFP151G9E030E111 0.70 db max. at +25 C 0. 80 db max. at -40 ~ +85 C 0.50 db max. at +25 C 0.60 db max. at -40 ~ +85 C 0.50

More information

Model TS-100 Tubing Spider Installation, Operation, Service and Parts Book Manual

Model TS-100 Tubing Spider Installation, Operation, Service and Parts Book Manual Model TS-100 Tubing Spider Installation, Operation, Service and Parts Book Manual WPI WELLKIN Inc. 8401 Industrial Dr. Pearland, TX 77584 PH: (281) 992-2064 FX: (281) 992-2076 E-mail: sales@wpiwellkin.com

More information

AMERICAN NATIONAL STANDARD FOR POWER ASSIST AND LOW ENERGY POWER OPERATED DOORS SPONSOR BHMA. bu iiders hardware man ufacturers association

AMERICAN NATIONAL STANDARD FOR POWER ASSIST AND LOW ENERGY POWER OPERATED DOORS SPONSOR BHMA. bu iiders hardware man ufacturers association ANSIIBHMA A156.19-2007 Revision ofansi/bhma A156.19-2002 AMERICAN NATIONAL STANDARD FOR POWER ASSIST AND LOW ENERGY POWER OPERATED DOORS SPONSOR all lia BHMA bu iiders hardware man ufacturers association

More information

VHSR-SERIES RACKS FOR SHEET MATERIAL

VHSR-SERIES RACKS FOR SHEET MATERIAL VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com

More information

MTS Criterion Series 40

MTS Criterion Series 40 MTS Criterion Series 40 Manual Title Lifting and Moving Additional Instructions Information be certain. 100-231-444 C Copyright information Trademark information Proprietary information Software validation

More information

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213 Code Compliance Research Report CCRR-0213 Issue Date: 08-04-2017 Renewal Date: 08-01-2018 DIVISION: 05 50 00 METAL FABRICATIONS Section: 05 52 00 Metal Railings REPORT HOLDER: Key Link Fencing & Railing,

More information

The University of Texas at Austin. Lift Safety Plan

The University of Texas at Austin. Lift Safety Plan The University of Texas at Austin Lift Safety Plan August 2012 President s Environmental Health and Safety Statement of Commitment The University of Texas at Austin is committed to protecting the health

More information

Material Handling & Industrial Storage Solutions

Material Handling & Industrial Storage Solutions Standard Product Catalog Material Handling & Industrial Storage Solutions platforms SPG brings greater organization to your organization with material handling systems from Gillis-Jarke. Today, more than

More information

BBL-4 FORK-MOUNTED BULK BAG LIFTER USE AND MAINTENANCE MANUAL

BBL-4 FORK-MOUNTED BULK BAG LIFTER USE AND MAINTENANCE MANUAL VESTIL MANUFACTURING CORP. 2999 North Wayne Street, P.O. Box 507, Angola, IN 46703 Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868 Fax: (260) 665-1339 www.vestilmfg.com e-mail: sales@vestil.com

More information

CHAPTER 10: FALL PROTECTION

CHAPTER 10: FALL PROTECTION CHAPTER 10: FALL PROTECTION PURPOSE The fall protection program provides information and procedures to minimize the occurrence of an accidental fall or falling object, resulting in injuries on a job site.

More information

FREEMAN DISPLAY LABOR

FREEMAN DISPLAY LABOR P. O. Box 14210 Orange, CA 92863-1610 714/254-3400 Fax: 714/490-0801 FreemanAnaheimES@freemanco.com NAME OF SHOW: COMPANY NAME: BOOTH#: CONTACT NAME: PHONE#: FAX #: Straight Time- 8:00 A.M. to 5:00 P.M.

More information

ArmorZone TL-2 Barrier and End Treatment

ArmorZone TL-2 Barrier and End Treatment ArmorZone TL-2 Barrier and End Treatment Product and Installation Manual ANOTHER AMORFLEX DEVELOPMENT Table of contents Introduction 3 System Overview 3 Before Installation 3 Limitations and Warnings 4

More information

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213 Code Compliance Research Report CCRR-0213 Issue Date: 08-01-2014 Revision Date: 08-28-2018 Renewal Date: 08-01-2019 DIVISION: 05 50 00 METAL FABRICATIONS Section: 05 52 00 Metal Railings REPORT HOLDER:

More information

INTERCONNECTION APPLICATION AND AGREEMENT

INTERCONNECTION APPLICATION AND AGREEMENT INTERCONNECTION APPLICATION AND AGREEMENT With Terms and Conditions for Interconnection For a Level 1 Review (Certified Inverter-based Units under 10kW) Mailing Address PSE&G Net Metering 750 Walnut Avenue

More information

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual Contact Information Models: DBLLSG-9-GAL to DBLLSG-24-GAL DBLLSG-9-PCY to DBLLSG-24-PCY DBLLSG-9-SS to DBLLSG-24-SS

More information

EKX k. Man-Up Turret Truck (2,750-3,300 lbs.) Versatile design with modular construction and intelligent truck management system

EKX k. Man-Up Turret Truck (2,750-3,300 lbs.) Versatile design with modular construction and intelligent truck management system Versatile design with modular construction and intelligent truck management system 80 Volt 3-phase advanced AC technology providing powerful torque and high productivity Low cost of operation through two-fold

More information

PRO-SHORE. Shoring Systems

PRO-SHORE. Shoring Systems Shoring Systems Features and Benefits The new Pro-Shore Shoring System consists of special drophead post shores, aluminum ledgers (mains), and laminated wood joists (secondaries) or panels. This system

More information

Aerial and Scissor Lift

Aerial and Scissor Lift This document is intended to provide basic safety guidelines for the Physical Plant Department at Community College of Allegheny County. The information provided in this guide may vary by site. Version

More information

Scaffolding. Safety Guide. STOP! Before you climb

Scaffolding. Safety Guide. STOP! Before you climb Scaffolding Safety Guide Printed FEB 2015 rebr. AUG 2016 Contents Safety Guide Disclaimer... 1 Safety Guide Objectives... 2 Roles & Responsibilities of Workplace Parties Employers, Supervisors, Workers...

More information

VP2 SidePOD Instructions

VP2 SidePOD Instructions VP2 SidePOD Instructions www.siemon.com Safety Information - Read and understand all instructions for proper installation and use of this product as improper use may lead to serious injury or death - To

More information

APPLICATION FOR PORCH/DECK COVER SHEET

APPLICATION FOR PORCH/DECK COVER SHEET APPLICATION FOR PORCH/DECK COVER SHEET Project Address The following items must be completed and submitted as a packet: 1. Porch/Deck permit application 2. One (1) set of plans (for new construction),

More information

USER S MANUAL HAKI PUBLIC ACCESS STAIR

USER S MANUAL HAKI PUBLIC ACCESS STAIR USER S MANUAL HAKI PUBLIC ACCESS STAIR HAKI AB 2017 Important information HAKI s product liability and user s manuals apply only to scaffolds that are entirely composed of components that have been made

More information

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual Models: All Models Contact Information Table of Contents: Safety Precautions... 2 Product Information... 2 Support Channel

More information

Aerial Lift and Scaffolding Guidelines

Aerial Lift and Scaffolding Guidelines Aerial Lift and Scaffolding Guidelines November 2018 Aerial Lift and Scaffolding Guidelines TABLE of CONTENTS I. General II. III. IV. Roles and Responsibilities Types of Aerial Lifts Operating Requirements

More information

Multi-Purpose Scaffolding Instruction Manual

Multi-Purpose Scaffolding Instruction Manual Limited Warranty World Factory, Inc. World Factory, Inc. (Seller) warrants to the original Buyer only, that each YellowStone Product will be free from defects in material and workmanship for a period of

More information

Implement Loading Dock Buyers Guide

Implement Loading Dock Buyers Guide Implement Loading Dock Buyers Guide Basic Trailer Unloading Mobile Ramp Portable Loading Dock Mobile Loading Dock Fixed Position Loading Dock Portable Loading Docks Specialty Loading Docks Railcar Unload

More information

IMPORTANT INFORMATION - PLEASE READ PRIOR TO ORDERING

IMPORTANT INFORMATION - PLEASE READ PRIOR TO ORDERING IMPORTANT INFORMATION - PLEASE READ PRIOR TO ORDERING HANGING TRUSS & LIGHTING EQUIPMENT Freeman personnel/employees must operate all chain motors, including the final trim. Freeman personnel/employees

More information

Big Ox Energy Siouxland, LLC. Safety Management System. Authority: President

Big Ox Energy Siouxland, LLC. Safety Management System. Authority: President Issuing Dept: Safety Page: Page 1 of 5 Purpose The purpose of this program is to provide guidelines to Big Ox Energy - Siouxland LLC employees in the safe use of scaffolding, and to reduce the risk of

More information

April 2013 Vehicle Restraints 101

April 2013 Vehicle Restraints 101 April 2013 Vehicle Restraints 101 1 Germantown, WI 53022 What You Always Wanted to Know About Vehicle Restraints But Were Afraid to Ask Just what the heck is a vehicle restraint? A vehicle restraint is

More information

Forklift Safety WARNING. Failure to heed this warning may result in personal injury and/or property damage.

Forklift Safety WARNING. Failure to heed this warning may result in personal injury and/or property damage. Forklift Safety 10.6 WARNING Study, understand and follow all instructions: Provided in this complete manual Listed below On system safety labels Failure to heed this warning may result in personal injury

More information

Maximize Your Space. Mezzanines are ideal for:

Maximize Your Space. Mezzanines are ideal for: www.vertispace.ws Maximize Your Space Worker productivity and manufacturing efficiencies are under constant scrutiny in today s business world. Whether you re an operations manager charged with expanding

More information

PENTALIFT ELEVATING DOCKS

PENTALIFT ELEVATING DOCKS PRODUCT INFORMATION PENTALIFT ELEVATING DOCKS 2946 Larimer St. Denver, CO 80205 303-295-1100 / 800-373-7693 FAX 303-295-2464 Email info@snyderequipment.com www.snyderequipment.com Could This Happen At

More information

3/15/2017. New US and Canadian Aerial Work Platform Standards. Subject Matter Expertise. Overview WARNING

3/15/2017. New US and Canadian Aerial Work Platform Standards. Subject Matter Expertise. Overview WARNING New US and Canadian Aerial Work Platform Standards Tony Groat IPAF North America Manager - Session T44 To earn Professional Development Hours (PDH): 1. Log into the CONEXPO CON/AGG App 2. Go to this session

More information

Aviation & Industrial Work Stands and Lifts

Aviation & Industrial Work Stands and Lifts Aviation & Industrial Work Stands and Lifts Aviation & Industrial Work Stands Introduction...1 In-House Engineering.....2 C-5 Variable Height Engine Work Stand. 5 Multi-Height Maintenance Platform..8 FireScout

More information

Code Compliance Research Report CCRR-0171

Code Compliance Research Report CCRR-0171 Code Compliance Research Report CCRR-0171 Issue Date: 08-26-2011 Revision Date: 06-20-2018 Renewal Date: 06-30-2019 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 63 00 Plastic Railings REPORT

More information

Unispan. Self-Support System

Unispan. Self-Support System Unispan Self-Support System NEW YOU ARE IN CONTROL WITH THE HUFCOR TOUCH PAD Electric Unispan Hufcor now offers the best of both worlds by combining the convenience and simplicity of touch-of-a-button

More information

Model 292A. Surface Resistance Test Kit. Instruction Manual

Model 292A. Surface Resistance Test Kit. Instruction Manual Model 292A Surface Resistance Test Kit Instruction Manual Printed in USA Copyright 2016 Monroe Electronics, Inc. Specifications subject to change without notice. P/N 0340198 292A/100 04122016 100 Housel

More information