Instruments and Reagents for Water Analysis

Size: px
Start display at page:

Download "Instruments and Reagents for Water Analysis"

Transcription

1 Instruments and Reagents for Water Analysis

2 Table of Contents Methods of Analysis...2 Quick Reference by Parameter...4 Visual Systems MiniKits / Test Kits Aqua Comparator...8 Comparator and Nesslerizer System...18 Colorimeters Series 942, Single Parameter Colorimeter...24 SC400, Single Parameter Colorimeter...28 MC500, Multi-Parameter Colorimeter...32 Spectrophotometers SP600 Spectrophotometer...38 Reagents for Colorimeters and Spectrophotometers...44 COD Reactor TR125 Thermoreactor...64 Turbidimeters TB200 Portable Turbidimeter...66 TB300 Lab Turbidimeter...68 BOD Oxi700 BOD System...70 Electrochemistry ph COND DO Floc Testers / Jar Testers ET740 For Laboratory...,.. 79 ET750 For Laboratory......,...79 ET730 Portable...79 Pool and Spa Products...80

3 Methods of Analysis Colorimetric Methods These tests are generally simple and easy to run the basic concept is one of adding a specific reagent which reacts with the analyte being tested to create a color. The intensity of this color is then measured. You can visually compare the intensity of the color developed against a known standard with our Aqua Comparator or Comparator 705. Or for even better accuracy, you can measure the color using a colorimeter (see our SC400, 942 or MC500) or our SP600 Spectrophotometer. As you will see, Orbeco-Hellige has a full line of colorimetric water quality tests. Titrations Titrations are simple chemical tests in which a solution or tablet of a known concentration is added slowly to a sample of unknown concentration. At a given point, (called the end point) the color of the sample will rapidly change, such as from red to blue. An easy calculation will then allow determination of the concentration of the analyte. Orbeco s MiniKits (Page 8) are convenient, innovative titration kits that use tablets as the titrant. Electrochemical Methods Some parameters in water such as ph, ORP and Conductivity can be measured using an electrochemical meter. These are precise instruments which (in effect) measure the flow of electricity through a water sample. In addition, other electrochemical instruments can measure Dissolved Oxygen in the sample using membrane technology. Orbeco s line of Electrochemical Instruments can be found starting on Page 76 of this catalog. 2 Phone: / Fax:

4 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Respirometric Methods BOD is a measurement of the oxygen update (or demand) of microbiological organisms in a wastewater sample. Orbeco- Hellige offers an innovative product called the Oxi700 which allows precise BOD measurement without error prone sample dilutions. In addition, it can start providing BOD data within 1 day of initiating the test. The Oxi700 can be found on Page 72 of this catalog and is the perfect tool for process control purposes. Turbidimetric Methods Turbidity is basically a measurement of the cloudiness of the water. Sources of water cloudiness may include dissolved organic and inorganic materials. To meet US EPA guidelines, turbidity detection has to be done by measuring the diffraction of a white light source at a 90 degree angle. Orbeco offers several different turbidimeters, starting on Page 68. For more information about the Methods of Analysis, instruments, or reagents please contact our Customer Service department. You can reach us by: Phone: or (Toll-Free USA) Fax: E-mai: service@orbeco.com Web: We will be happy to assist you.

5 Quick Reference By Parameter Parameter Mini Kits and Test Kits Comparator 705 Aqua Comparator Test Kits 942 Colorimeter SC400 Colorimeter MC500 Colorimeter SP600 Spectrophotometer Acid Demand p p Alkalinity-M (Total) p p p p p Alkalinity-P p p p p Aluminum p p p p p Ammonia p p p p Ammonia Nitrogen p Arsenic p p Barium p Biquanide (See PHMB) p p Boron p p Bromine p p p Cadmium p p Chloride p p p p Chlorine p p p p p p Chlorine Dioxide p p p p p Chromate p Chromium p p p COD p p p p Color (of Water) p p Copper p p p p p Cyanide p p p Cyanuric Acid p p p p DEHA p p p p Fluoride p p p p p p Formaldehyde p Hardness, Calcium p p p p Hardness, Total p p p p Hazen p (Pt-Co-Units ; APHA) p Hydrazine p p p p Hydrogen Peroxide p p p Iodine p p p Iron (Fe 2+, Fe 3+ ), soluble p p p p p p Lead p p p Magnesium p Manganese p p p p p 4 Phone: / Fax:

6 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Parameter Mini Kits and Test Kits Comparator 705 Aqua Comparator Test Kits 942 Colorimeter SC400 Colorimeter MC500 Colorimeter SP600 Spectrophotometer Molybdate p p p p Nickel p p Nitrate p p p p Nitrite p p p p p Nitrogen p p Organophosphonate (OP) p p Oxygen, Active p Oxygen, Dissolved p p Ozone p p p p ph p p p p p ph in Soil p Phenols p p PHMB (Biguanide) p Phosphate p p p p p p Potassium p p p Silica p p p p p p Sodium Hypochlorite (See Chlorine) Spectral p Absorption-Coefficient Sulfate p p p p Sulfide p p p Sulfite p p p p p Surfactants (anionic) p p Tannin p p TOC p Turbidity (nephelometric) p Turbidity p (attenuated radiation method) Q.A.C. (Quanternary p Ammonium Comp.) Urea p p Zinc p p p p Quick Reference By Parameter

7 Minikits and Test Kits Highlights Easy to use with exact reagent dosing Cost effective Tablet reagents have a guaranteed shelf life of 5 years Easy and safe storage The MINIKITS are designed for rapid water testing. Most of the MINIKITS are based on titrimetric methods. Tablet Count Method: In the tablet count method, the liquid titration solution and indicator are replaced by Orbeco-Hellige tablet reagents. A specified number of tablets are added to a defined sample volume until a chemically induced color change takes place. The concentration of the parameter being measured is calculated from the number of tablets required. The measuring range can be expanded by varying the sample volume. Speed Test: The speed test is based on reverse titration. After adding a reagent tablet to a calibrated test tube, the water sample is added slowly until the color of the solution changes (i.e. from red to blue). The user can then read the result of the liquid level. Yes/No Test: A Yes/No test can determine if a specific ingredient is present in the water and/or if its concentration is higher or lower than a defined level. Arsenic Test Kit The Arsenic Test Kit is able to accurately detect very low ranges of arsenic, and can be used to determine the presence of arsenic in drinking water. The kit includes enough materials to perform 100 tests. Meets WHO requirements for drinking water. This Test Kit is able to detect levels as low as mg/l Arsenic. To minimize the potential danger to the user, the Test Kit does not use a highly toxic lead acetate for sulfide removal. Instead, the removal of interfering sulfide ions is integrated into the test procedure. To avoid irritation of the skin, the acid substance is in the form of a solid. The unbreakable plastic reaction bottle is safe and convenient for on-site testing purposes. During the test procedure, the developing arsine gas is tightly sealed inside the reaction bottle. Unable to escape, it cannot harm the user. P/N L Turbidity Method: A two-section calibrated tube is filled with sample and a reagent tablet is added. The reagent creates a level of turbidity that is proportional to the concentration of the parameter being measured. The inner tube, which has a black dot on its base, is lowered until the dot is obscured by the turbidity. The result is read from the water level in the inner tube. 6 Phone: / Fax:

8 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Minikits Parameter Test Kit P/N Method Range Replacement Reagents P/N Alkalinity, Total L Speed Test mg/l mmol/l RT557-0 Alkalinity Caustic/P L Tablet Count mg/l RT510-1 RT511-0 Alkalinity-P L Tablet Count mg/l RT510-1 Alkalinity-M L Tablet Count mg/l mmol/l RT511-0 Calcium Hardness L Speed Test mg/l mmol/l RT558-0 Calcium Hardness L Tablet Count mg/l mmol/l RT519-1 Chloride L Tablet Count mg/l RT513-1 Cyanuric Acid L Turbidity mg/l RT132-0 Hardness, VLR (Total) L Tablet Count 1-10 mg/l, mmol/l RT535-1 Hardness, LR (Total) L Tablet Count 1-50 mg/l, mmol/l RT517-0 Hardness (Total) L Yes / No Limit 4 mg/l, 8 mg/l, or 20 mg/l RT or 0.08 or 0.2 mmol/l Hardness (Total) L Speed Test mg/l mmol/l RT559-0 Hardness (Total) L Tablet Count mg/l mmol/l RT516-1 Nitrite L Tablet Count mg/l RT520-1 RT521-1 Organophosphonate L Tablet Count 1-20 mg/l L RT296-1 QAC (Quaternary L Tablet Count mg/l RT541-0 Ammonium Comp.) Yes / No (limit 200 mg/l) Sulfate, LR L Tablet Count mg/l RT522-1 RT523-1 Sulfate L Turbidity mg/l RT545-1 Sulfite, LR L Tablet Count 2-50 mg/l RT527-1 RT528-1 (For testing Bolier water) RT533-1 Sulfite, HR L Tablet Count mg/l RT527-1 RT528-1 (For testing Bolier water) RT533-1 Tannin Index L Tablet Count units RT350-0 RT351-1 Minikits and Test Kits Test Kits Arsenic Test Kit L mg/l Reorder as a complete Test Kit Organic Matter 815 Visual Comparison See Kit In Sand Soil ph Test Kit 694 Reorder as a complete Test Kit

9 Aqua Comparator Highlights Easy to use Economical Continuous color disc TM Powder Pack chemistries available 8 Phone: / Fax:

10 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The Aqua Comparator is an accurate, easy to use test kit for water analysis. Simply add the reagent to the sample cell, rotate the disc until the color matches the sample and read the concentration value. The instructions provide a step-by-step explanation of how to conduct the water test, ensuring that even "non-chemists can achieve reliable and accurate measurements quickly. Test Kit includes: Comparator, Color Disc, Sample Cells, Instructions, Reagents, and Carrying Case. Aqua Comparator Test Kits Parameter Form of Range (Accuracy ± 5% Full Scale) Part Reagent Number Alkalinity (Total) Tablet mg/l CaCO 3 L Aluminum Tablet mg/l Al L Ammonia Tablet 0-1 mg/l N L Ammonia Powder Pack mg/l N L Bromine Tablet 0-5 mg/l Br L Chlorine, Free & Total (DPD) Tablet mg/l Cl 2 L Chlorine, Free & Total (DPD) Tablet 0-1 mg/l Cl 2 L Chlorine, Free & Total (DPD) Tablet 0-2 mg/l Cl 2 L Chlorine, Free (DPD) Powder Pack mg/l Cl 2 L Chlorine, Total (DPD) Powder Pack mg/l Cl 2 L Chlorine, Free + Total (DPD) Powder Pack mg/l Cl 2 L Chlorine, Free & Total (DPD) Tablet 0-4 mg/l Cl 2 L Chlorine HR (KI) Tablet mg/l Cl 2 (Total) L Chlorine Dioxide Tablet mg/l ClO 2 L Chlorine UHR, Sodium Hypochlorite Tablet 2-18 % L Copper HR, Free & Total Tablet 0-5 mg/l Cu L Copper HR, Free Powder Pack 0-5 mg/l Cu L Copper LR, Free & Total Tablet 0-1 mg/l Cu L Copper LR, Free Powder Pack 0-1 mg/l Cu L DEHA Tablet / Liquid mg/l DEHA L Iron HR Tablet 1-10 mg/l Fe L Iron LR Tablet mg/l Fe L Iron (TPTZ) Powder Pack mg/l Fe L Molybdate Tablet mg/l MoO 4 L Molybdate LR Tablet 0-10 mg/l MoO 4 L Nitrate HR Tablet mg/l NO 3 L Nitrite LR Tablet mg/l N L Nitrite Powder Pack mg/l N L ph (Phenol red) Tablet ph L ph Tablet ph L ph Tablet ph L ph Tablet 4-10 ph L Phosphate Powder Pack mg/l PO 4 L Phosphate Tablet 0-80 mg/l PO 4 L Phosphate LR Tablet 0-4 mg/l PO 4 L Silica HR Powder Pack mg/l SiO 2 L Silica VLR Tablet 0-1 mg/l SiO 2 L Sulfite LR Tablet mg/l SO 2-3 L Zinc Tablet 0-1 mg/l Zn L Aqua Comparator

11 Aqua Comparator Parameters, Test Kits, Discs, and Replacement Reagents Parameter Range Readings (Accuracy ± 5% Full Scale) Test Kit P/N Alkalinity (Total) mg/l 20 /30 / 40 / 50 / 60 / 70 / 80 / 90 / 100 / 110 / 120 / 130 L CaCO / 150 / 160 / 170 / 180 / 190 / 200 / 220 / 240 Aluminum mg/l Al 0 / 0.01 / 0.02 / 0.03 / 0.04 / 0.05 / 0.06 / 0.07 / L / 0.09 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 Ammonia 0-1 mg/l N 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / L / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.9 / 0.95 / 1.0 Ammonia mg/l N 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5 L Bromine 0-5 mg/l Br 0 / 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 1.2 / 1.4 / 1.6 / 1.8 / 2 / 2.5/ L / 3.5 / 4 / 4.5 / 5 Chlorine (Free, Combined**, mg/l Cl / 0.03 / 0.04 / 0.05 / 0.06 / 0.07 / 0.08 / 0.09 / 0.1 / 0.11 / 0.12 / 0.13 / 0.14 / 0.15 / 0.16 / 0.17 / 0.18 / 0.19 / L and Total) 0.2 / 0.22 / 0.24 / 0.26 / 0.28 / mg/l Cl 2 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5 / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.85 L / 0.95 / mg/l Cl / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / 1.0 / 1.1 / 1.2 / 1.3 / 1.4 / 1.6 / 1.8 / 2.0 L mg/l Cl 2 0 / 0.2 / 0.4 / 0.6 / 0.8 / 1 / 1.2 / 1.4 / 1.6 / 1.8 / 2 / L (Free, Combined, Total) 2.2 / 2.4 / 2.6 / 2.8 / 3 / 3.2 / 3.4 / 3.5 L (Free) L147051(Total) 0-4 mg/l Cl 2 0 / 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 1.2 / 1.4 / 1.6 / 1.8 / 2.0 / 2.5 / 3.0 / 3.5 / 4.0 L Chlorine HR mg/l Cl 2 10 / 20 / 30 / 40 / 50 / 60 / 70 / 80 / 90 / 100 / 110 / 120 / L (Total) 130 / 140 / 150 / 160 / 170 / 180 / 190 / 200 / 250 / 300 * RAPID: fast dissolving tablet **May be calculated by subtracting Free from Total Chlorine 10 Phone: / Fax:

12 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Aqua Comparator Discs Continuous Color Scale Economical Precise Disc P/N Reagents # of Tests Reagent P/N L Alkacheck Tablets 100 RT320-0 L Aluminum No. 1 Tablets 100 RT546-0 Aluminum No. 2 Tablets 100 RT547-0 Aluminum Reagent Set 100 each RS5460 L Ammonia No. 1 Tablets 100 RT258-0 Ammonia No. 2 Tablets 100 RT259-0 Ammonia Reagent Set 100 each RS5540 Ammonia Nitrogen Reagent Set RS5500 L DPD No.1-RAPID* Tablets 100 RT131-0BT L DPD No.1 Tablets 100 RT106-0BT DPD No.3 Tablets 100 RT108-0BT Chlorine Reagent Set RS1060 L DPD No.1-Rapid* Tablets 100 RT131-0BT DPD No.3-Rapid* Tablets 100 RT129-0BT DPD No.4-Rapid* Tablets 100 RT157-0BT L DPD No. 1-RAPID* Tablets 100 RT131-0BT DPD No. 3-RAPID* Tablets 100 RT129-0BT DPD No. 4 RAPID* Tablets 100 RT157-0BT L DPD Free Cl 2 Reagent 100 RP009-0 DPD Total Cl 2 Reagent 100 RP008-0 L DPD No.1-RAPID* Tablets 100 RT131-0BT DPD No. 3-RAPID* Tablets 100 RT129-0BT DPD No. 4 RAPID* Tablets 100 RT157-0BT L Chlorine HR (KI) Tablets 100 RT300-0 Acidifying GP Tablets 100 RT548-0 Each Aqua Comparator Disc contains a continuous color scale, making it easy to obtain an exact color match between the standard and sample. These discs are specially manufactured to retain their color stability, ensuring reliable, reproducible results. Aqua Comparator Chlorine Reagent Set 100 each RS5480 Material Safety Data Sheets:

13 Aqua Comparator Parameters, Test Kits, Discs, and Replacement Reagents Parameter Range Readings (Accuracy ± 5% Full Scale) Test Kit P/N Chlorine, UHR 2-18 % 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 / 11 / 12 / 13 / 14 / 15 / 16 / 18 L Sodium Hypochlorite (Total) Chlorine Dioxide mg/l 0.01 / 0.02 / 0.03 / 0.04 / 0.05 / 0.06 / 0.07 / 0.08 / 0.09 / L ClO / 0.11 / 0.12 / 0.13 / 0.14 / 0.15 / 0.16 / 0.17 / 0.18 / 0.19 / 0.2 Copper HR 0-5 mg/l Cu 0 / 0.5 / 1.0 / 1.5 / 2.0 / 2.5 / 3.0 / 3.5 / 4.0 / 4.5 / 5.0 L (Free and Total) Copper HR, 0-5 mg/l Cu 0 / 0.5 / 1.0 / 1.5 / 2.0 / 2.5 / 3.0 / 3.5 / 4.0 / 5.0 L (Free) Copper LR 0-1 mg/l Cu 0 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / 1.0 L (Free and Total) Copper LR 0-1 mg/l Cu 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5/ L (Free) 0.6 / 0.7 / 0.8 / 0.9 / 1.0 DEHA mg/l 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5 L DEHA Fluoride mg/l F 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 1.2 / 1.4 / 1.6 / 1.8 / Iron LR 0-1 mg/l Fe 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / L / 0.55 / 0.6 / 0.65 / 0.7 / 0.75 / 0.8 / 0.9 / 1.0 Iron HR 1-10 mg/l Fe 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5 / 5.5 / 6 / 6.5 / L / 7.5 / 8 / 8.5 / 9 / 10 Iron (TPTZ) mg/l Fe 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / L / 1.1 / 1.2 / 1.3 / 1.4 / 1.5 / 1.6 / 1.7 / 1.8 Manganese LR mg/l Mn 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / / 0.55 / 0.6 / 0.7 * RAPID: fast dissolving tablet **May be calculated by subtracting Free from Total Chlorine 12 Phone: / Fax:

14 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Plastic Cells with Lids Part Number: L Disc P/N Reagents # of Tests Reagent P/N L Chlorine HR (KI) Tablets 100 RT300-0 Acidifying GP Tablets 100 RT548-0 Chlorine HR Reagent Set 100 each RS5480 Accessories: Dilution set for sample preparation L L DPD No. 1 Tablets 100 RT106-0BT Glycine Tablets 100 RT217-0 Volume: 10 ml Path Length: 13.5 mm Available as a 10 pack Chlorine Dioxide Reagent Set RS7731 L Copper No. 1 Tablets 100 RT355-0 Copper No. 2 Tablets 100 RT356-0 Copper Reagent Set RS3550 L Copper Reagent 100 RP030-0 L Copper No. 1 Tablets 100 RT355-0 Copper No. 2 Tablets 100 RT356-0 Comparator Housing Part Number: L Aqua Comparator Copper Reagent Set 100 each RS3550 L Copper Reagent 100 RP030-0 L DEHA Tablets 100 RT322-0 DEHA solution 15 ml L L SPADNS Reagent 250 ml L L Iron LR Tablets 100 RT537-0 Iron (II) LR Tablets 100 RT542-0 L Iron HR Tablets 100 RT538-0 L Iron TPTZ Reagent 100 RP055-0 Iron Ferro Reagent 100 RP056-0 L Manganese LR 50 RS5090 Reagent Set Accessories: Rochelle Salt Solution 30 ml L needed for samples with hardness values above 300 mg/l CaCO 3 Front view of comparator Back view of comparator Material Safety Data Sheets:

15 Aqua Comparator Parameters, Test Kits, Discs, and Replacement Reagents Parameter Range Readings (Accuracy ± 5% Full Scale) Test Kit P/N Manganese VLR mg/l Mn 0.02 / 0.03 / 0.04 / 0.05 / 0.06 / 0.07 / 0.08 / 0.09 / 0.1 / / 0.12 / 0.13 / 0.14 / 0.15 / 0.16 / 0.18 / 0.2 Molybdate mg/l MoO 4 0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 45 / 50 / 55 / 60 / L / 70 / 75 / 80 / 85 / 90 / 95 / 100 Molybdate LR 0-10 mg/l MoO 4 0 / 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 / 10 L Nitrate HR mg/l NO 3 10 / 20 / 30 / 40 / 50 / 60 / 70 / 80 / 90 / 100 L Nitrate LR 0-1 mg/l N 0 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / Nitrite LR mg/l N 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5 L Nitrite mg/l N 0 / 0.01 / 0.02 / 0.03 / 0.04 / 0.05 / 0.06 / 0.07 / 0.08 / 0.09 / 0.10 L / 0.12 / 0.13 / 0.14 / 0.15 / 0.16 / 0.17 / 0.18 / 0.19 / / 0.22 / 0.23 / 0.24 / 0.25 / 0.26 / 0.27 / 0.28 / 0.29 / 0.30 Ozone (DPD) mg/l O 3 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5 / 0.55 / 0.6 / 0.65 / 0.7 L ph ph 5.2 / 5.3 / 5.4 / 5.5 / 5.6 / 5.7 / 5.8 / 5.9 / 6.0 / 6.1 / L / 6.3 / 6.4 / 6.5 / 6.6 / 6.7 / ph 6.0 / 6.1 / 6.2 / 6.3 / 6.4 / 6.5 / 6.6 / 6.7 / 6.8 / 6.9 / 7.0 / L / 7.2 / 7.3 / 7.4 / 7.5 / ph 6.5 / 6.6 / 6.7 / 6.8 / 6.9 / 7.0 / 7.1 / 7.2 / 7.3 / 7.4 / L / 7.6 / 7.7 / 7.8 / 7.9 / 8.0 / 8.1 / 8.2 / 8.3 / ph 4 / 4.5 / 5 / 5.5 / 6 / 6.5 / 7 / 7.5 / 8 / 8.5 / 9 / 9.5 / 10 L * RAPID: fast dissolving tablet **May be calculated by subtracting Free from Total Chlorine 14 Phone: / Fax:

16 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Disc P/N Reagents # of Tests Reagent P/N L Manganese LR (PP) Reagent Set RS5090 Accessories: Rochelle Salt Solution 30 ml L needed for samples with hardness values above 300 mg/l CaCO 3 L Molybdate No. 1 Tablet 100 RT306-0 Molybdate No. 2 Tablet 100 RT307-0 Molybdate Reagent Set 100 each RS3060 L Molybdate No. 1 Tablet 100 RT306-0 Molybdate No. 2 Tablet 100 RT307-0 Molybdate Reagent Set 100 each RS3060 L Nitracheck No. 1 Tablet 100 RT750-0 Nitracheck No. 2 Tablet 100 RT751-0 Nitrate, HR Reagent Set 100 each RS7701 L Nitrite LR Tablets 100 RT231-0 Nitrate-Test tablets 100 (bottle) L Nitrate Test powder 15 g L Nitrate/Nitrite Tube Test 24 L L Nitrite LR Tablets 100 RT231-0 L Nitrite 3 Powder Packs 100 RP098-0 L DPD No. 4-RAPID* Tablets 100 RT157-0BT Glycine Tablets 100 RT217-0 L Bromocresol Purple 100 RT173-0 L Bromothymol Blue 100 RT164-0 L Phenol Red-RAPID* 100 RT179-0BT L ph Universal 100 RT544-0 Reagent Tablets with Part Numbers ending with BT are part of Orbeco-Hellige s new line of Blister Packaging. Our tablets are manufactured in Germany under tightly controlled conditions using state-of-the art technology. Each tablet is hermetically sealed within an aluminum foil pocket, making it easy for the user to simply push the tablet through the protective foil and straight into the sample. We guarantee a minimum shelf life of 5 years, and in some cases, a shelf life of up to 10 years. Aqua Comparator Material Safety Data Sheets:

17 Aqua Comparator Parameters, Test Kits, Discs, and Replacement Reagents Parameter Range Readings (Accuracy ± 5% Full Scale) Test Kit P/N Phosphate 0-80 mg/l PO 4 0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 45 / 50 / 55 / L / 65 / 70 / 75 / 80 Phosphate LR 0-4 mg/l PO 4 0 / 0.25 / 0.5 / 0.75 / 1.0 / 1.25 / 1.5 / 1.75 / 2.0 / 2.25 / L / 2.75 / 3.0 / 3.25 / 3.5 / 3.75 / 4.0 Phosphate mg/l PO 4 0 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / 1 / 1.1 / 1.2 L / 1.4 / 1.5 / 1.6 / 1.7 / 1.8 / 1.9 / 2 / 2.1 / 2.2 / 2.3 / 2.4 / 2.5 Silica LR mg/l SiO / 0.5 / 0.75 / 1.0 / 1.25 / 1.5 / 1.75 / 2.0 / 2.5 / 3.0 / 3.5 / 4 L Silica HR mg/l SiO 2 0 / 10 / 20 / 30 / 40 / 50 / 60 / 70 / 80 / 90 / 100 L Silica VLR 0-1 mg/l SiO 2 0 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.35 / 0.4 / 0.45 / 0.5 / L / 0.7 / 0.8 / 0.9 / 1.0 Sulfite LR mg/l SO / 1 / 1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 4.5 / 5 / 6 / 7 / 8 / 9 / 10 L Zinc 0-1 mg/l Zn 0 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / 0.9 / 1.0 L * RAPID: fast dissolving tablet **May be calculated by subtracting Free from Total Chlorine 16 Phone: / Fax:

18 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Disc P/N Reagents # of Tests Reagent P/N L Phosphate HR Tablets 100 RT198-0 L Phosphate No. 1 LR Tablets 100 RT304-0 Phosphate No. 2 LR Tablets 100 RT305-0 Phosphate Reagent Set RS3040 L Phosphate 3 Powder Pack 100 RP155-0 L Silica No. 1 Tablets 100 RT313-0 Silica No. 2 Tablets 100 RT314-0 Silica P/R Tablets 100 RT315-0 Silica Reagent Set 100 each RS Silica HR Reagent Set 100 RS5700 L Silica No. 1 Tablets 100 RT313-0 Silica No. 2 Tablets 100 RT314-0 Silica P/R Tablets 100 RT315-0 Silica Reagent Set 100 each RS3130 L Sulfite LR Tablets 100 RT802-0 L Copper/Zinc LR Tablets 100 RT262-0 EDTA Tablets 100 RT239-0 Dechlor Tablets 100 RT235-0 Zinc Reagent Set 100 each RS2620 Some of our Aqua Comparator Test Kits use Orbeco-Hellige s line of Powder Pack reagents. Powder Pack TM reagents are pre-measured, unit dose powder reagents, making it quick and easy to accurately perform tests. For a complete list of available Powder Pack reagents, please see pages These reagents have been specially formulated to provide accurate results with Orbeco-Hellige, Hach and other manufacturer s spectrophotometers, colorimeters and test kits. Aqua Comparator Material Safety Data Sheets:

19 Comparator 705 Highlights Easy to use Compensation for colored or turbid samples Integrated prism Consistancy guaranteed with our permanent colored glass standards 18 Phone: / Fax:

20 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Hand-held and completely portable, the Comparator 705 from Orbeco-Hellige is ideal for testing water, wastes, boiler and cooling water, process fluids, swimming pools, spas and more. It is ideal for the lab, plant, field or classroom. Users will find this system extremely easy to use, and to be uncompromising in terms of precision and reproducibility of results. The comparator incorporates a magnifying prism which brings the colors of the standards and test sample side-by-side and into one image, helping the user to make an exact color match. The Comparator 705 can be used for a wide variety of color measurement applications. For more information, please contact our sales department or visit our website at Comparator and Accessories Item P/N Comparator H Comparator 705 with 2 Sample Cells 705-AHT Sample Cell, 13 mm, 10 ml volume 600-T13P Daylight Illuminator 700-DA1 Portable Daylight Unit 700-DA2 Nesslerizer System 711-A1 Set of Nessler Tubes, 200 mm path length w/ Plungers L Glass stirring rod, 12 cm length L Plastic Stirring Rod L Brush, 11 cm length L P/N: 711-A1 Includes Nesslerizer, 2 Nessler Tubes and 2 Plungers. Comparator 705 and Nesslerizer Systems P/N: 700-DA1 P/N: 700-DA2 While working in the laboratory or out in the field, Orbeco-Hellige strongly recommends the use of one of our daylight units. They provide uniform lighting conditions regardless of conditions and help achieve reproducible results.

21 Comparator 705 Parameter Disc P/N Standards Range Method Chlorine 330-D 0 / 0.1 / 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / mg/l Acid o-tolidine 1.5 / 2.0 / D 0 / 0.2 / 0.5 / 1.0 / 2.0 / 3.0 / mg/l Acid o-tolidine 4.0 / 6.0 / 8.0 / D 0 / 0.05 / 0.1 / 0.2 / 0.3 / 0.4 / mg/l Acid o-tolidine 0.5 / 0.6 / 0.8 / D 0 / 5.0 / 15.0 / 25.0 / 50.0 / 75.0 / / mg/l Acid o-tolidine / / D 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 1.5 / 2.0 / 2.5 / 3.0 / mg/l DPD 431-D 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.8 / 1.0 / 1.5 / mg/l DPD 432-D 0.1 / 0.2 / 0.25 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / 0.8 / mg/l Acid o-tolidine 433-D 0 / 0.1 / 0.2 / 0.25 / 0.3 / 0.4 / 0.5 / 0.6 / 0.7 / mg/l DPD 533-D / 0.3 / 0.5 / 0.7 / 0.9 / 1.0 / 3.0 / 5.0 / 7.0 / mg/l Acid o-tolidine / 0.05 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 / 0.6 / 0.8 / mg/l O-Tolidine Chromate / 0.01 / 0.02 / 0.03 / 0.04 / 0.05 / 0.06 / mg/l Carbazide 0.08 / 0.10 / 0.12 Color of Water / 2.5 / 5 / 7.5 / 10 / 12.5 / 15 / 17.5 / 20 / Color Units Pt - Co / 5 / 10 / 15 / 20 / 30 / 40 / 50 / 60 / Color Units Pt - Co A 0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / Color Units Pt - Co / 10 / 20 /30 / 40 / 50 / 60 / 70 / 80 / Color Units Pt - Co / 200 / 250 / 300 / 400 / Color Units Pt - Co Fluoride / 0.1 / 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 1.2 / 1.4 / mg/l Scotts-Sanchis Test discs The accuracy of results can only be ensured by using our permanent color standards. Glass standards are fade-free, resistant to chemicals and scratchproof. Orbeco-Hellige standards are made from colored glass filters. and comply with international standards (ISO 7393/2) Phone: / Fax:

22 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Reagent Size Reagent Disc Outfit Required Accessories Part Number Ortho-Tolidine Solution 2 oz. R DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Ortho-Tolidine Solution 2 oz. R DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Ortho-Tolidine Solution 2 oz. R DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Ortho-Tolidine Solution 2 oz. R DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size DPD No. 1 Tablets 50 Tablets 431-IT 430-DA 13mm Plastic Tubes (600-T13P) DPD No. 3 Tablets 50 Tablets 433-IT DPD No. 1 Tablets 50 Tablets 431-IT 431-DA 13mm Plastic Tubes (600-T13P) DPD No. 3 Tablets 50 Tablets 433-IT Ortho-Tolidine Solution 2 oz. R DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size DPD No. 1 Tablets 50 Tablets 431-IT 433-DA 13mm Plastic Tubes (600-T13P) DPD No. 3 Tablets 50 Tablets 433-IT Ortho-Tolidine Solution 2 oz. R DA13 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Ortho-Tolidine Solution 2 oz. R A Nesslerizer, 200 mm Tubes Reagent also available in a 4, 16, or 32 oz. size Arsenite Reagent 1 oz. R Reagent also available in a 4, 16, or 32 oz. size Carbazide Reagent Tablet 10 Tablets R TAB A Nesslerizer, 200 mm Tubes Reagent also available 40 or 80 Tablets Carbazide Diluting Reagent 4 oz. R Reagent also available in a 16, or 32 oz. size No Reagent Required Nesslerizer, 200 mm Tubes No Reagent Required Nesslerizer, 200 mm Tubes No Reagent Required Nesslerizer, 200 mm Tubes No Reagent Required Nesslerizer, 200 mm Tubes No Reagent Required Nesslerizer, 200 mm Tubes Zirconium Oxychloride 1 oz. Sodium Alizarin Monosulfonate 1 oz. R R A Nesslerizer, 200 mm Tubes Acid Diluting Solution Fluoride 16 oz. R Comparator 705 and Nesslerizer Systems Disc Outfits include the Orbeco-Hellige Color Disc and a 1 ounce starter supply of liquid reagents or tablets.

23 Comparator 705 Parameter Disc P/N Standards Range (mg/l) Method Hydrazine 376-D 0.0 / 0.01 / 0.02 / 0.04 / 0.06 / 0.08 / 0.1 / mg/l DMAB 0.2 / 0.3 / 0.5 ph 155-D 5.0 / 5.2 / 5.4 / 5.6 / 5.8 / 6.0 / 6.2 / 6.4 / ph Bromcresol Purple (Narrow Range) 160-D 4.8 / 5.0 / 5.2 / 5.4 / 5.6 / 5.8 / 6.0 / 6.2 / ph Chlorphenol Red-D 170-D 6.0 / 6.2 / 6.4 / 6.6 / 6.8 / 7.0 / 7.2 / 7.4 / ph Bromthymol Blue-D 180-D 6.8 / 7.0 / 7.2 / 7.4 / 7.6 / 7.8 / 7.9 / ph Phenol Red 8.0 / 8.2 / D 7.2 / 7.4 / 7.6 / 7.8 / 8.0 / 8.2 / 8.4 / 8.6 / ph Cresol Red-B 187-D 7.6 / 7.8 / 8.0 / 8.2 / 8.4 / 8.6 / 8.8 / 9.0 / ph Thymol Purple-D 190-D 8.0 / 8.2 / 8.4 / 8.6 / 8.8 / 9.0 / 9.2 / 9.4 / ph Thymol Blue-B 195-D 8.4 / 8.6 / 8.8 / 9.0 / 9.2 / 9.4 / 9.6 / 9.8 / ph Cresol Phthalein-D ph 250-D 2.0 / 3.0 / 4.0 / 5.0 / 6.0 / 7.0 / 8.0 / 9.0 / 10.0 / ph Wide Range (Wide Range) Indicator 250-DA1 1.0 /2.0 / 3.0 / 4.0 / 4.25 / 4.5 / 4.75 / 5.0 / 5.25 / ph Wide Range Indicator 250-DA2 5.5 / 5.75 / 6.0 / 6.25 / 6.5 / 6.75 / 7.0 / 7.25 / ph Wide Range 7.5 / 7.75 Indicator 250-DA / 8.0 / 8.25 / 8.5 / 8.75 / 9.0 / 9.25 / ph Wide Range 9.5 / 10.0 / 11.0 Indicator 250-D30 Disc Set Includes : 250-D1, 250-D2, 250-D3 Phosphate 355-D 0 / 10.0 / 20.0 / 30.0 / 40.0 / 50.0 / 60.0 / mg/l Ortho 80.0 / / D 0 / 2 / 4 / 6 / 8 / 10 / 12 / 16 / 20 / mg/l Ortho and Poly Silica 362-D 0 / 10.0 / 20.0 / 30.0 / 40.0 / 50.0 / 60.0 / mg/l S-molybdate / SO / / D 0 / 2 / 5 / 10 / 15 / 20 / 25 / 30 / 40 / mg/l 22 Phone: / Fax:

24 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Reagent Size Reagent Disc Outfit Required Accessories Part Number P-Dimethylaminobenzalheyde R GM 376-DA 13mm Plastic Tubes (600-T13P) Hydrazine Diluting Rgt. 4 oz. R Reagent also available in a 16, or 32 oz. size Bromcresol Purple Soln. 2 oz. 155-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Chlorphenol Red-D Soln. 2 oz. 160-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Bromthymol Blue-D Soln. 2 oz. 170-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Phenol Red Ind. Soln. 2 oz. 180-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Cresol Red-B Ind. Soln. 2 oz. 185-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Thymol Purple-D Soln. 2 oz. 187-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Thymol Blue-B Soln. 2 oz. 190-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Cresol Phthalein-D Soln. 2 oz. 195-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Wide Range Indicator 2 oz. 250-S DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Wide Range Indicator 2 oz. 250-S DA1A 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Wide Range Indicator 2 oz. 250-S DA2A 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size Wide Range Indicator 2 oz. 250-S DA3A 13mm Plastic Tubes (600-T13P) Reagent also available in a 4, 16, or 32 oz. size 250-D30A Molybdate Reagent 2.5 % 4 oz. R DA 13mm Plastic Tubes (600-T13P) Reagent also available in a 16, or 32 oz. size Amino Sulfonic Acid Rgt. R-262 Sulfuric Acid, 12.0 N Ammonium Molybdate,10% 4 oz. 4 oz. R R DA 13mm Plastic Tubes (600-T13P) These reagents also available in a 16, or 32 oz. size Amino Sulfonic Acid Rgt. 100 GM R GM This reagent also available in 500 GM size Hydrochloric Acid, oz. R DA 13mm Plastic Tubes (600-T13P) Ammonium Molybdate 11.4% 4 oz. R Sodium Sulfite, 22.7% 4 oz. R These reagent also available in a 16, or 32 oz. size Comparator 705 and Nesslerizer Systems Disc Outfits include the Orbeco-Hellige Color Disc and a 1 ounce starter supply of reagents or tablets.

25 Series 942 Colorimeter Highlights Direct-read digital display of procedural prompts and test results Factory calibrated, no user adjustments are ever needed. Microprocessor controlled self diagnosis of power, circuitry and lamp readiness Phone: / Fax:

26 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The Mini Analyst The Mini Analyst single parameter colorimeters are easy-to-use and portable for fast, precise water tests. Economically priced, the 942 is ideal for when a single specific test is performed frequently. All models come complete with reagents and carrying case. Orbeco-Hellige provides you with the most models available to perform water analysis covering a wide variety of uses and applications. Every Mini Analyst is designed and programmed to perform one specific test, with the highest level of accuracy and convenience. You will never have to buy reagents for tests you will never use! All models provide direct-reading in the digital display in mg/l or p.p.m. Most models use single dose reagent tablets. Tablets are convenient, easy to transport, pre-measured and hermetically sealed for a long shelf-life. Specifications Power Supply Auto-off Display Detector Light Source Calibration 3 AA batteries automatically switches off after 15 minutes of non-use. 2 line, 16 alpha numeric character LCD. Silicon photodiode. LED Automatic Zero Set and Automatic Standardization by microprocessor. Operator controlled Auto-Blank. Housing Dimensions (L x W x H) Weight Certification Rugged plastic, resistant to water, corrosion and impact x 3.6 x 2.1 inches 1 lb. 4 lbs. to ship CE Series 942, The Mini Analyst Part Number 975-TG 975-TP Description Sample Tubes, Glass (set of 4) Sample Tubes, Plastic (set of 4)

27 Series 942 Colorimeter Parameter / Model P/N Range Replacement # of Method (mg/l) Reagent P/N Tests Alkalinity (M) Alkalinity (P) Alkalinity (Total) Aluminum / ERC Ammonia, Nitrogen LR/ Indophenol Ammonia Nitrogen HR Barium / Turbidimetric Bromine / DPD Calcium Hardness Chloride / Argentometric / Chlorine (Free & Total) / / DPD Chlorine (Total) / DPD Chlorine, HR / Idometric Chlorine Dioxide / DPD Chromate / Idometric Chromium, Hexavalent / Diphenylcarb COD, LR / Micro-reflux /60MF 50 COD, MR / Micro-reflux /61MF 50 COD, HR / Micro-reflux Copper (Free & Total) / Bicinchoninate Cyanide (Free) / Cyanogen Chloride Cyanuric Acid / Turbidimetric DEHA p.p.b Fluoride / ECR HardnessLR (Total) / Calmagite Hardness (Total) Hydrazine / p.p.b Dimethylaminobenz Hydrogen Perioxide, LR / DPD Hydrogen Perioxide, HR Phone: / Fax:

28 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The Mini Analyst Parameter / Model P/N Range Replacement # of Method (mg/l) Reagent P/N Tests Iodine / DPD Iron LR (Total) / PPST Iron HR (Total) / o-phenanthroline Lead / Dithizone p.p.b Magnesium Magnesium Hardness Manganese, LR / Leucomalachite p.p.b Manganese, HR / Periodate Molybdate, LR Molybdate, MR Molybdate, MR / Thiocyanate Molybdate, HR / Thioglycollate Nickel / Dimethylgloxime Nitrate / Reduction / Nitrite, LR / Diazotization Nitrite, HR / Iodometric Organophosphonate & Phosphate (Total) Oxygen (Dissolved) / Winkler Ozone / DPD Phenol / Aminoantipyrine Phosphate LR (Ortho) / Moly. Blue Phosphate MR (Ortho) / Ascorbid Phosphate HR (Ortho) / Vanadomoly Phosphate (Total) Silica, LR / Heteropoly Blue Silica, MR Silica, HR / Molybdosilicate Sulfate / Turbidimetric Sulfite Surfactant Tannin & Lignin Zinc / Zincon Series 942, The Mini Analyst

29 SC400 Single Parameter Colorimeter Highlights Waterproof Internal data storage TM Powder Pack or tablet reagents Real time clock Portable Backlit display 28 Phone: / Fax:

30 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The SC400 is Orbeco-Hellige s new series of rugged, waterproof, single parameter colorimeters for laboratory or field testing. Available in a wide range of parameters, the SC400 mainly uses powder pack and tablet chemistries, ensuring accurate doses of reagents. The instrument features a large, backlit display for easy viewing of results, as well as a real time clock, datalogging capabilities, and a user calibration mode which allows the user to calibrate against prepared standards. Every SC400 comes complete with a battery, 3 sample cells, reagents, instruction manual, and carrying case. Specifications Users can find MSDS and information about product updates by visiting Optics Power Supply Auto-off Display temperature compensated LED and photo sensor amplifier 9V power pack battery providing 40 hours of operation automaticly switches off backlit LCD Storage ability to store up to 16 data sets Additional feature Calibration Housing real time clock and date Comes with factory calibration. Ability to set user defined calibrations. waterproof Dimensions 6.7 x 2.6 x 1.8 inches (L x W x H) Weight approx. 1/2 pound Environmental temperature: F conditions rel. humidity: 30 90%, non-condensing Certification CE SC400 Colorimeter

31 SC400 Single Parameter Colorimeter Parameter Range (mg/l) Model Number # of Tests Form of Replacement Reagent Reagents P/N Aluminum SC Powder Pack/Liquid RS5000 Ammonia SC Powder Pack RS5500 Chlorine , SC Powder Pack (Free) RP010-0 (Free and Total) Powder Pack (Total) RP012-0 Chlorine SC Powder Pack RP010-0 / RP012-0 (Free and Total) Tablet RT106-0BT / RT122-0BT Chlorine/pH , SC Powder Pack (Free) RP010-0 (Free and Total) ph Powder Pack (Total) RP012-0 Liquid L Chlorine Dioxide SC Powder Pack RP101-0 Tablet RT217-0 COD* SC Tube Test (0-150 mg/l) a, b TT ,500 ( mg/l) a, b TT ,000 ( mg/l) a, b TT20722 COD Set 0-15,000 SC400-01S See the following page for details. Copper SC Powder Pack RP030-0 Fluoride* c SC Liquid L Standard R Iron (TPTZ) SC Powder Pack RP055-0 Iron (Ferro) SC Powder Pack RP056-0 Manganese LR SC Powder Pack/Liquid RS5090 Manganese HR SC Powder Pack RS5100 Phosphate SC Powder Pack RP155-0 Silica SC Powder Pack RS5700 *This SC400 model does not come with reagents. The user must order reagents separately. a Available in 150 count pack b Mercury-Free version available c Both Reagent and Standard are required to perform test Part Number L L L L L L Description Multi Vial, 10 mm with lid, 12 pack, for use with Model Number SC Multi Vial,10 mm with lid, 5 pack, for use with Model Number SC Sample Cell, 24 mm with lid, 12 pack Sample Cell, 16 mm with lid, 10 pack Chlorine Reference Standard Kit, Confirms the Standards of Zero, 0.20 and 1.0 (For use with SC400-10). Cleaning Cloth For Sample Cells 30 Phone: / Fax:

32 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL SC400 COD Set The Orbeco-Hellige SC400 COD Set comes complete with everything you need for COD analysis. Simply add sample to the Orbeco-Hellige COD tube test vial, heat it in the TR-125 Thermoreactor, and then analyze the sample using the SC400 Single Parameter Colorimeter for COD. The COD Set comes with the SC400 COD Colorimeter, 16 mm adapter, 25 tube tests for both Low (0-150 mg/l) and Mid ( mg/l) Range COD analysis, the TR-125 Thermoreactor to aid in sample digestion, and a tube test stand. P/N: SC400-01S SC for COD Measurement Tube Tests The Orbeco-Hellige tube tests are available for the measuring the following COD ranges : mg/l mg/l mg/l Also available Mercrury-Free Their chemical properties and a 16 mm tube diameter are suitable also for use with Hach colorimeters. For more COD Reagent information, see pages 52 and 53 SC400 COD Specifications Optics temperature-compensated LEDs and photosensor amplifier in water proof sample chamber Ranges mg / l O 2 ±3.5% *) mg / l O 2 ±3.5% *) mg / l O 2 ±3.5% *) Power 9 V powerpack battery supply providing 40 hours operation Auto - OFF automatic switch-off Display backlit LCD (on keypress) Storage ability to store up to 16 data sets Additional real time clock feature and date Calibration factory calibration and user calibration. Reset to factory calibration possible Dimensions 6.7 x 2.6 x 1.8 inches (L x W x H) Weight approx. 1/2 pound (base unit) Environmental Temperature: F conditions rel. humidity: 30 90% (non condensing) Certification CE * based on the use of potassium-hydrogenephthalate standards (DIN ) SC400 Colorimeter for COD Analysis: SC (Colorimeter and case only) TR125 Specifications For more information, see page 67 Housing Front key pad Round metal block in epoxy covered housing, 24 holes 16 mm diameter Robust membrane keypad with 4 keys Temperature 70/100/120/150 C settings 158/212/248/302 F ± 0.3 C Timer Heating 30, 60, and 120 minutes with continuous operation, automatic switch-off with alarm 400 Watts electronically controlled, with overheating protection TR125 Thermoreactor: TR12500 (Thermoreactor only) SC400 Colorimeter mg/l TT20720, 25 Count TT20725, 150 Count TT20710, 25 Count, Mercury Free mg/l TT20721, 25 Count TT20726, 150 Count TT20711, 25 Count, Mercury Free TT20716, 150 Count, Mercury Free mg/l TT20722, 25 Count TT20727, 150 Count TT20712, 25 Count, Mercury Free

33 MC500 Multi-Parameter Colorimeter Highlights Industry-leading 6 wavelength photo detector array Automatic wavelength selection Infrared interface for data transfer Waterproof Internal Data Storage of 1,000 results Portable Able to test over 70 Methods 32 Phone: / Fax:

34 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The MC500 is the Muti-Parameter Colorimeter from Orbeco-Hellige. This versatile instrument tests for a wide range of water quality parameters from Alkalinity to Zinc, and its compact size makes it perfect for use in either the field or laboratory. Using Orbeco-Hellige s Open Reagent System (which uses Powder Pack TM, tablets, liquid, and ampoule reagents), the MC500 features an industry-leading 6 LED photodetector array that allows the instrument to conduct over 70 pre-programmed test methods and over 20 user defined methods. Up to 1,000 data sets can be stored in the instrument s internal memory and transfered to a computer using the Orbeco-Hellige s new Infrared Interface Module, the IRiM (See pg. 39) The MC500 comes with 3 of the 24 mm sample cells, 3 of the 16 mm sample cells, 16 mm tube adapter, 13 mm tube adapter, batteries, instruction manual, and carrying case. Specifications Display Interfaces Optics Graphic-display Infrared interface for test data transfer 1, RJ45 socket for Internet updates 2 Light-emitting diodes and photosensorintensifier featuring automatic wave length selection. Wavelength range: 1 = 530 nm IF λ = 5 nm 2 = 560 nm IF λ = 5 nm 3 = 610 nm IF λ = 6 nm 4 = 430 nm IF λ = 5 nm 5 = 580 nm IF λ = 5 nm 6 = 660 nm IF λ = 5 nm IF = interference filter Wavelength ± 1 nm Accuracy Photometric 2% FS (T = 68 F 77 F) Accuracy* Colorimetric A Resolution Operation Acid and solvent resistant, touch-sensitive keypad with audible feedback via integrated beeper Power Supply 4 batteries (Mignon AA/LR6); Operation time: approx. 26 hours continuous operation or 3500 tests Auto-Off approx. 20 minutes after last keypress with audible signal Dimensions approx x 3.7 x 1.8 (L x W x H) inches (unit) approx. 15.5x 11.6 x 4.2 inches (case) Weight (unit) approx. 1 lb (450 g) Operating Conditions Language Selection Memory Capacity Certification CE F 30 90% relative humidity non condensing English, German, French, Spanish, Italian,Portugese, and Polish approx data sets 1 optional available: IRiM (Infrared Data Transfer Module) 2 optional available: connection cable with integrated electronics * tested with standard solutions MC500 Multi-Parameter Colorimeter

35 MC500 Multi-Parameter Colorimeter Parameter Method Range # of Tests Form of Replacement (mg/l) Reagent Reagents Acid Demand, ph 4.3 Acid/Indicator mmol/l 100 Tablet RT321-0 Alkalinity-M (Total) Acid/Indicator Tablet RT321-0 Alkalinity-P Acid/Indicator Tablet RT323-0 Aluminum Eriochrome cyanide R (Tablet) Tablet RS5460 Aluminum Eriochrome cyanide R (Powder) Powder Pack RS5000 Ammonium Indophenole Tablet RS5540 Ammonium Salicylate Powder Pack RS5500 Ammonium, LR Salicylate Powder Pack RS5600 Ammonium, HR Salicylate Powder Pack RS5650 PHMB (Biguanide) Buffer/Indicator Tablet RT610-0 Boron Azomethine Tablet RS5050 Bromine DPD Tablet RT106-0BT Calcium Hardness Murexide Tablet RT565-0 Chloride Silver nitrate/turbidity Tablet RS5910 Chlorine, Free DPD Powder Pack RP010-0 Chlorine, Total DPD Powder Pack RP012-0 Chlorine DPD Tablet RS1060 Chlorine DPD Liquid RS1056 Chlorine, HR Potassium Iodide/Acid Tablet RS5480 Chlorine, UHR Potassium Iodide % NaHCl 100 Tablet RS5480 Chlorine Dioxide DPD Tablet RS1060 COD, LR Dichromate/H 2 SO Tube Test Tube Test TT20720* TT20725 COD, MR Dichromate/H 2 SO Tube Test Tube Test TT20721* TT20726* COD, HR Dichromate/H 2 SO Tube Test Tube Test TT20722* TT20727 Copper Biquinoline Tablet RS3550 Copper, Free Bicichoninate Powder Pack RP030-0 Cyanide Pyridine-barbituric acid Powder & L Liquid Cyanuric Acid Melamine Tablet RT132-0BT DEHA PPST µg/l 100 Tablet RS3220 DEHA PPST µg/l 100 Powder Pack RS6000 Fluoride SPANDS ~125 Liquid L Hardness, Total Metallphthalein Tablet RT566-0 Hardness, Total HR Metallphthalein Tablet RT566-0 Hydrazine Dimethylaminobenzaldehyde Liquid RS2910 Hydrazine Dimethylaminobenzaldehyde ~100 Liquid L Hydrazine PDMAB Ampoules L * Mercury-Free version available 34 Phone: / Fax:

36 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Parameter Method Range # of Tests Form of Replacement (mg/l) Reagent Reagents Hydrogen Peroxide DPD/Catalyst Tablet RT238-0 Iodine DPD Tablet RT106-0BT Iron (II, III) Soluble PPST Tablet RS5370 Iron (II, III) Soluble 1, 10-Phenanthroline Powder Pack RP056-0 Iron (Total) TPTZ Powder Pack RP055-0 Manganese Formaldoxime Tablet RS6080 Manganese, LR PAN Powder & RS5090 Liquid Manganese, HR Periodate Oxidation RS6500 Molybdate Thioglycolate Tablet RS3060 Molybdate, HR Mercaptoacetic acid Powder Pack RS5300 Nitrate Chromotropic acid Powder Pack RS5580 Nitrite N(1-Naphthyl) ethylenediamine Tablet RT231-0 Nitrite, LR Diazotization Powder Pack RP098-0 Nitrogen, Total LR Persulfate Digestion method Powder Pack RS5550 Nitrogen, Total HR Persulfate Digestion method Powder Pack RS5560 Oxygen, active DPD Tablet RT122-0BT Oxygen, dissolved Rhodazine D TM µg/l 30 Ampoules L Ozone DPD/Glycine Tablet RS5555 Phosphate, ortho LR Phosphormolybdic blue/ Tablet RS3040 Ascorbic acid Phosphate, ortho HR Vanado molybdate Tablet RS5810 Phosphate, ortho Ascorbic acid Powder Pack RP155-0 Phosphate, ortho Ascorbic acid Powder & RS5200 Liquid Phosphate, Acid digestion Powder & RS5250 acid-hydrolyzable Tube Test Phosphate, Total Acid persulfate digestion Powder & Tube Test RS5210 Phosphate 1, ortho Vanado molybdate Ampoules L Phosphate 2, ortho Stannous chloride Ampoules L ph-value Bromocresol purple Tablet RT570-0 ph-value Phenol Red Tablet RT177-0BT ph-value Phenol Red ml Liquid L ph-value Thymol blue Tablet RT571-0 Potassium Tetraphenylborate (Turbidity) Tablet RT567-0 Silica Silicomolybdate Powder Pack RS3130 Silica, LR Heteropoly blue Powder Pack RS5690 Silica, HR Silicomolybdate Powder Pack RS5700 Sulfate Barium sulfate (Turbidity) Tablet RT545-0 Sulfate Barium sulfate (Turbidity) Powder Pack RP216-0 Sulfide DPD/Catalyst Tablet RS2930 Sulfite DTNB Tablet RT802-0 Urea Indophenol/Urease Tablet & RS9300 Liquid Zinc Zincon Tablet RS2620 MC500 Multi-Parameter Colorimeter

37 MC500 Multi-Parameter Colorimeter Part Number MC MC L L L L L L Description MC500, Multi-Parameter Colorimeter IRiM, Infrared Data Transfer Module Verification Standard Kit, MC500 (Zero/430/530/560/580/610/660 nm) Multi Vial, Plastic, 10 mm with lid, 12 pack Multi Vial, Plastic, 10 mm with lid, 5 pack Sample Cell, Glass, 24 mm with lid, 12 pack Sample Cell, Glass, 16 mm with lid, 10 pack Cleaning Cloth For Sample Cells Verification Standard Kit The Verification Standard Kit for the MC500 is designed to confirm the accuracy and reliability of measurement results. Orbeco-Hellige recommends testing your instrument with this kit every three months to ensure the greatest accuracy. Confirms the Standards of: Zero, 430, 530, 560, 580, 610, and 660 nm The shelf life of the Verification Standard Kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. P/N L Phone: / Fax:

38 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL IRiM: Data Transfer Module The IRiM uses state-of-the-art infrared technology to transmit data from the MC500 Multi-Parameter Colorimeter to one of 3 optional interfaces. Users can choose to connect to a Computer, a USB printer or a serial printer. The interface can be easily selected, and the choice is displayed by an LED function indicator. The user can switch between the interfaces using a "Select" button. The IRiM comes with the software necessary to begin quickly and easily transfering data to your computer. As an option the data can be saved as an Excel spreadsheet or a.txt file. Measurement data can quickly be printed out, using a specified USB or serial printer connected to the IRiM. The IRiM comes ready for use, with the following accessories : USB cable, 4 batteries, screwdriver, CD-ROM, operating instructions and guarantee certificate P/N: MC Highlights Facilitates infared data transfer of data to a computer without comprimising the MC500 s waterproof housing. Option of 3 different interfaces Ability to quickly and easily save data in an Excel spreadsheet Specifications Dimensions (L x W x H) Weight Power supply Connections Controls Certification 4.8 x 3.6 x 1.65 inches ~ 0.5 lb. 4 AA alkaline batteries or, if available : USB-PC interface USB device USB host RS232 Acid & solvent-proof tactile foil keyboard CE MC500 Multi-Parameter Colorimeter P/N MC500-60

39 SP600 Spectrophotometer Highlights Pre-programmed Orbeco-Hellige methods Large, illuminated display Innovative sample chamber allows different shaped cells to be used without adapter Internal data storage Countdown function 35 user-defined methods 38 Phone: / Fax:

40 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The SP600 is a single-beam spectrophotometer. The instrument performs a self-test as soon as it is turned on, confirming proper operation and performance of all key components. Using an innovative tungsten halogen lamp with flash function, the lamp is on only momentarily during the measurement process, eliminating a warm-up period. An integrated Didymium-filter confirms the instrument is working properly and assures data integrity. Using a unique holographically-produced monochromator, the light is split into special ranges, where a moveable mirror ensures that light of the desired proper wavelength is focused automatically as it passes through the water sample. The light not absorbed by the sample travels to the silicon photodiode detector. The signal is then evaluated by a microprocessor and shown as a direct-read result in the display Tungsten halogen lamp 2. Monochromator 3. Movable mirror 4. Sample chamber 5. Silicon photodiode 6. Microprocessor unit Specifications Wavelength range Photometric range Spectral bandwidth Wavelength accuracy Wavelength reproducibility Light source Monochromator Detector 330 to 900 nm -0.3 to 2.5 Abs 10 nm ±2 nm ±1 nm Pre-adjusted tungsten halogen lamp Holographic grating Silicon photodiode Multifunctional Round vials sample chamber for 24 and 16 mm Ø, Rectangular cells mm Display Language options Backlit LCD graphic display German, English, French, Italian, Spanish, Portugese Storage capacity 1000 test data sets Serial interface RS-232 Dimensions x x 5.9 (L x W x H) inches Weight Power supply unit Certification approx. 7 pounds Input: V 1.0 A Hz Output:12 V to 30 W CE SP600 Spectrophotometer

41 SP600 Spectrophotometer An innovative, multifunctional, sample chamber eliminates the need for most adapters. Round vials measuring 16 mm and 24 mm in diameter and rectangle cells with pathlengths from 10 to 50 mm do not require any adapter. Wavelength Scanning and User Calibrations. A wavelength scan can be performed over a user-defined interval between 330 and 900 nm. With this function, an operator can measure standards of different concentrations to create user calibrations of up to 10 order polynominal. New Methods. New test methods are always being added. Users can easily add new methods to their instrument by downloading free software from our website. Data Logging and Handling. An RS-232 connection allows for the instrument to be connected with a PC or printer. Each data point is recorded with the date, time, operator number, measuring range, and method number. The instrument is able to store up to 1,000 data points in its internal memory. Low Maintenance. The only required maintenance is the eventual replacement of the halogen bulb. Users will find this to be quick and easy, as the bulb is conveniently located at the back of the SP no tools required! Multi-functional Sample Chamber Measurement Methods. The user chooses the desired method either from the alphabetical method list or by entering a numerical code. The SP600 can easily provide additional information such as the required vial, reagent type, and measuring range by using the function keys. The date and time are shown in the display by pressing the clock button. The SP600 automatically selects the correct wavelength. Zero Test. The zero test is performed with the water sample by pressing the ZERO key. Countdown Function. Some tests require a waiting period after a reagent is added to the sample. The SP600 s countdown function keeps the time for you by continuously displaying the remaining time. With ten seconds left, an alarm alerts the user, and measurment begins automatically. The result is then shown on the display. The user can turn off the countdown function to allow rapid completion of a series of samples. AC or Battery Powered. The SP600 can be run on battery power with an available battery pack Phone: / Fax:

42 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Parameter Method Range # of Tests Form of Replacement (mg/l) Reagent Reagents Acid Demand, ph 4.3 Acid/Indicator mmol/l 100 Tablet RT321-0 Alkalinity-M (Total) Acid/Indicator Tablet RT321-0 Alkalinity-P Acid/Indicator Tablet RT323-0 Aluminum T Eriochrome Cyanide R Tablet RS5460 Aluminum Eriochrome Cyanide R Powder Pack RS5000 Ammonium Indophenole Blue Tablet RS5540 Ammonium Salicylate Powder Pack RS5500 Ammonium, LR Salicylate Powder Pack RS5600 Ammonium, HR Salicylate Powder Pack RS5650 Arsenic Silver Diethyldithiocarbamate Boron Azomethine Tablet RS5050 Bromine DPD Tablet RT106-0 Cadmium Cadion Tube Test L Chloride Iron (III)-Thiocyanate Liquid L Chloride T Silver Nitrate/Turbidity Tablet RS5910 Chlorine DPD Tablet RS Chlorine DPD Liquid RS Chlorine DPD Powder Pack RP010-0 (Free and Total) RP012-0 Chlorine KI Tablet RS5480 Chlorine Dioxide DPD Tablet RS1060 Chlorine Dioxide DPD Tablet RS1060 Chromium 1, 5- Diphenylcarbozide 1, Powder Pack RP730-0 RP731-0 COD, LR Dichromate/H 2 SO Tube Test TT20720* TT20725 COD, MR Dichromate/H 2 SO Tube Test TT20721* TT20726* COD, HR Dichromate/H 2 SO Tube Test TT20722* TT20727 SP600 Spectrophotometer *Mercury-Free version available A wavelength scan is performed over the user defined interval between 330 and 900 nm. The display shows the graph of the spectrum; if the user presses a button, the display also shows a data list with the corresponding maximum and minimum absorption.

43 SP600 Spectrophotometer Parameter Method Range # of Tests Form of Replacement (mg/l) Reagent Reagents Color of Water Direct Reading Not Required Copper Biquinoline Tablet RS3550 Copper, Free Bicichoninate Powder Pack RP030-0 Cyanide Pyridine-Barbituric Acid Powder Pack L & Liquid Cyanuric Acid Melamine Tablet RT132-0BT DEHA PPST (Tablet) µg/l 100 Tablet RS3220 DEHA PPST (Powder) µg/l 100 Powder Pack RS6000 Fluoride SPANDS ~125 Liquid L Formaldehyde H 2 SO 4 /Chromotropic Acid 1-5, Liquid L Formaldehyde H 2 SO 4 /Chromotropic Acid Tube Test L Hardness, Total Metallphthalein Tablet RT566-0 Hardness, Total HR Metallphthalein Tablet RT566-0 Hazen (Pt-Co-Scale: APHA) Direct Reading Not Required Hydrazine Dimethylaminobenzaldehyde Liquid RS2910 Hydrazine Dimethylaminobenzaldehyde ~100 Liquid L Hydrogen Peroxide DPD/Catalyst Tablet RT238-0 Iodine DPD Tablet RT106-0BT Iron (II, III) Soluble PPST Tablet RS5370 Iron (II, III) Soluble 1, 10-Phenanthroline Powder Pack RP056-0 Iron (Total) TPTZ Powder Pack RP055-0 Lead 4-(2-Pyridylazo)-Resorcin Liquid L Lead 4-(2-Pyridylazo)-Resorcin Tube Test L Manganese Formaldoxime Tablet RS6080 Manganese, LR PAN Powder Pack RS5090 & Liquid Manganese, HR Periodate Oxidation Powder Pack RS6500 Molybdate Thioglycolate Tablet RS3060 Molybdate, HR Mercaptoacetic Acid Powder Pack RS5300 Nickel Dimethylglyoxime , Powder Pack & Liquid L Nitrate Chromotropic Acid Powder Pack RS5580 Nitrate 2,6-Dimethylphenole Tube Test L Nitrite N(1-Naphthyl) Ethylenediamine Tablet RT231-0 Nitrite Sulfamic Acid, , 24 Tube Test L Naphthylamine Nitrite, Total 2, 6-Dimethylphenole Powder Pack RP098-0 Nitrogen, LR (Total) Persulfate Digestion method Powder Pack RS5550 Nitrogen, HR (Total) Persulfate Digestion method Powder Pack RS5560 Ozone DPD/Glycine Tablet RS5555 Phenol 4-Aminoantipyrine Tablet RT595-0 RT Phone: / Fax:

44 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Parameter Method Range # of Tests Form of Replacement (mg/l) Reagent Reagents Phosphate, ortho LR Phosphormolybdic Blue/ Tablet RS3040 Ascorbic Acid Phosphate, ortho HR Vanado Molybdate Tablet RS5810 Phosphate, ortho Ascorbic Acid Powder Pack RP155-0 Phosphate, ortho Ascorbic Acid Powder Pack RS5200 & Liquid Phosphate, Acid digestion Powder Pack RS5250 acid-hydrolyzable & Tube Test Phosphate, Total Acid Persulfate digestion Powder Pack RS5210 & Tube Test Phosphate 1, ortho Vanado Molybdate Ampoules L Phosphate 2, ortho Stannous Chloride Ampoules L ph-value Phenol Red Tablet RT177-0BT ph-value Phenol Red ml Liquid L Potassium Tetraphenylborate (Turbidity) Tablet RT567-0 Silica Silicomolybdate Powder Pack RS3130 Silica, LR Heteropoly blue Powder Pack RS5690 Silica, HR Silicomolybdate Powder Pack RS5700 Sulfate Barium Sulfate (Turbidity) Powder Pack RP216-0 Sulfide DPD/Catalyst Tablet RS2930 Sulfite DTNB Tablet RT802-0 Surfactants (anionic) Methylene Blue Tube Test L TOC H 2 SO 4 /Persulfate/Indicator Tube Test L Turbidity Attenuated Radiation Method Not Required Urea Indophenol/Urease Tablet & RS9300 Liquid Zinc Zincon Tablet RS2620 SP600 Spectrophotometer Part Number L L L L L L L L L L Description SP600 Spectrophotometer External Battery Pack for SP600, 12 V Ni/Cd SP600 Serial Cable SP600 Carrying Case SP600 Secondary Standard Set Rectangular Cell, 10mm Rectangular Cell, 50mm Rectangular Cell, UV Quartz, 10mm SP600 Spectrophotometer Lamp Assembly, Pre-adjusted Cleaning cloth for sample cells

45 Reagents Tablet reagents Orbeco-Hellige is proud to offer a full range of reagents. From tablets, to powder packs, to liquids; we have you covered for over 100 different parameters. Specifications and Certificate of Analysis To see the high quality standards of Orbeco-Hellige s reagents, users can find specifications for each type of liquid and powder pack, as well as a Certificate of Analysis for each lot. Just visit the downloads section of our website by going to Material Safety Data Sheets (MSDS) for all reagents are also available on our website. Private Labeling Orbeco-Hellige has the capability of private labeling reagents. Please contact our sales department for further details. DPD reagents All of our DPD reagents are produced on the basis of international standard methods and the ISO standard method. The chemicals are of crystalline white nature. If a reagent (tablets or powder) is not white but has turned a grey/brown or purple color, it has deteriorated. DPD liquid reagents should be colorless when fresh and may turn a brownish color if the reagent has deteriorated. The use of deteriorated products must be avoided as they will give false results. Our test tablets are manufactured in Germany under tightly controlled conditions on the State-of-the-Art machinery. Maintaining the highest quality standards allows us to guarantee our tablets for a minimum of 5 years, and some for as long as 10 years. Each tablet is hermetically sealed within an individual aluminum foil pocket, protecting against environmental conditions. This packaging keeps each tablet in perfect condition, right up until the time it is needed by the user. Test tablets remain the most consistent and reliable reagent format available, routinely outperforming other reagent formats, and delivering maximum accuracy for the user. Our new blister packaging brings adds convenience to the protection achieved in Orbeco-Hellige s long established tablet production technology. With the new blister strip, the user just pushes the tablet through the protective foil, straight into the sample. Simple, time-saving and practical. Each tablet is contained within an individually formed foil cup, lined with the latest aluminum composite material, and guaranteeing product performance. As a result of improved sealing efficiency, the blister pack has been reduced in size to 91 x 34 mm making them even more convenient for storage and shipping. BT is added to the end of the part number to identify the new style of packaging. (For example RT106-0BT). There are no safety risks if the tablets are used in line with the instructions supplied Phone: / Fax:

46 Tube tests Liquid reagents Powder Packs Orbeco-Hellige s tube tests enable the user to easily perform highly sensitive and precise water testing. Using tube tests measurements are considerably faster and easier, particularly in the case of standard and serial tests. Tube tests contain a precisely measured amount of reagent, thereby avoiding the presence of extra chemicals and optimising test safety. Up to six different measuring ranges are available for the various tests. The tubes are made of special optical glass with a 16 mm diameter. They are supplied in a storage and dispatch box together with the digestion or auxiliary reagents. This packaging unit contains 24 or 25 reaction vials and up to 2 zero vials for photometer system calibration. As a rule, liquid reagents are comprised of several components that need to be added to the sample in a certain order. As both the size and the number of drops have a decisive effect on the color complex result, the reagents need to be added with a high degree of precision. The shelf life of liquid reagents is reduced by temporary contact with oxygen when the bottle is opened, as well as by improper storage environments (presence of sunlight or high temperatures). Provided that the bottles are stored within the temperature range 43 F to 50 F, the Orbeco- Hellige DPD and Phenol Red solutions can be used for a period of one year from the production date. The fast and easy use of Powder Packs has made them extremely popular for water testing applications in many countries throughout the world. The Orbeco-Hellige Powder Packs provide users with a real alternative to existing measurement systems. The Powder Packs are produced with the same high quality standards as our tablet reagents. Parameters from aluminum and chlorine to sulphate are just some of the well-known tests that are included in the Powder Pack range. Their chemical properties are suitable for use with Hach-Colorimeter-Systems. Reagents Orbeco-Hellige, Inc Parkland Drive Sarasota, FL

47 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell SC400 MC500 SP600 Acid Demand mmol/l Acid/Indicator 1, 2 24 mm ø Alkalinity-M (Total) mg/l Acid/Indicator 1, 2, 5 24 mm ø Alkalinity-P mg/l Acid/Indicator 1, 2, 5 24 mm ø mg/l Aluminum mg/l Eriochrome Cyanine R 2 24 mm ø Aluminum mg/l Eriochrome Cyanine R 2 24 mm ø mg/l Ammonia mg/l Indophenole Blue 2, 3 24 mm ø Ammonia mg/l Salicylate 2 24 mm ø Ammonia LR mg/l Salicylate 2 16 mm ø Ammonia HR 1-50 mg/l Salicylate 2 16 mm ø Arsenic (III, IV) mg/l 507 Silver diethyl- 20 mm o Dithiocarbamate 1 Biguanide (see PHMB) Boron mg/l Azomethine 3 24 mm ø MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 46 Phone: / Fax:

48 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of Reagent/Quantity Order code Alka-M Photometer Tablet / 100 RT321-0 CaCO 3 Alka-M Photometer Tablet / 100 RT321-0 CaCO 3 Alka-P Photometer Tablet / 100 RT323-0 Al Aluminum Reagent Set Powder Pack / 100 RS5000 Al Aluminum No. 1 Tablet / 100 RT546-0 Aluminum No. 2 Tablet / 100 RT547-0 Aluminum Reagent Set Tablet / 100 each RS5460 N Ammonia No. 1 Tablet / 100 RT258-0 Ammonia No. 2 Tablet / 100 RT259-0 Ammonia Reagent Set Tablet / 100 each RS5540 Ammonia Conditioning Reagent (for seawater) Powder / 15 g / 100 tests L N Ammonia Nitrogen Reagent Set Powder Pack / 100 RS5500 N Ammonia LR Reagent Set Powder Pack / 50 RS5600 Reagents N Ammonia HR Reagent Set Powder Pack / 50 RS5650 As See Instruction Manual For Required Reagents - - B Boron No. 1 Tablet / 100 RT579-0 Boron No. 2 Tablet / 100 RT580-0 Boron Reagent Set Tablet / 100 each RS5050 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500 Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

49 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell SC400 MC500 SP600 Bromine mg/ L DPD 5 24 mm ø mg/l mm o mg/l mm o mg/l mm ø Cadmium (Cd 2+ ) mg/l Cadion 16 mm ø Chloride mg/l Silver Nitrate/Turbidity 24 mm ø Chloride 5-60 mg/l Iron (III)-Thiocyanate 4 24 mm ø Chlorine a) mg/l DPD 1, 2 24 mm ø mg/l mm o mg/l mm o mg/l mm ø Chlorine a) mg/l DPD 1, 2 24 mm ø mg/l 24 mm ø Chlorine a) mg/l DPD 1, 2 24 mm ø mg/l mm ø multi vial Chlorine HR (KI) mg/l KI / Acid 5 16 mm ø Chlorine, UHR % Potassium Iodide 5 24 mm ø Sodium Hypochlorite MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 48 Phone: / Fax:

50 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of Reagent/Quantity Part Number Br DPD No. 1 Tablet / 100 RT106-0BT DPD No. 1 High Calcium e) Tablet / 100 RT574-0 Cd Cadmium Tube Test d) Tube test / 25 L Cl Chloride T1 Tablet / 100 RT591-0 Chloride T2 Tablet / 100 RT592-0 Cl Chloride Reagent Set Reagent test (Liquid reagent) L approx. 75 tests Cl 2 DPD No. 1 DPD No. 3 Tablet / 100 Tablet / 100 RT106-0BT RT108-0BT DPD No. 1 High Calcium e) Tablet / 100 RT574-0 Chlorine Reagent Set Tablet / 100 each RS1060 Cl 2 Chlorine Reagent Set Liquid / 15 ml each RS1056 Cl 2 DPD Free Chlorine Powder Pack / 100 RP010-0 DPD Total Chlorine Powder Pack / 100 RP012-0 Reagents Cl 2 Acidifying GP Tablet / 100 RT548-0 Chlorine HR (KI) Tablet / 100 RT300-0 Chlorine HR (KI) Reagent Set Tablet / 100 each RS5480 NaOCl Acidifying GP Tablet / 100 RT548-0 Chlorine HR (KI) Tablet / 100 RT300-0 Chlorine HR (KI) Reagent Set Tablet / 100 each RS5480 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

51 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell SC400 MC500 Chlorine Dioxide mg/l DPD/Glycine 1,2 24 mm ø mg/l mm o mg/l mm ø SP600 Chlorine Dioxide mg/l mm ø Chromium a) b) mg/l ,5-Diphenylcarbozide 1, 2 50 mm o mg/l mm ø COD LR (ISO 15705: ) b) mg/l Dichromate / H 2 SO 4 1, 2 16 mm ø COD MR (ISO 15705: ) b) mg/l Dichromate / H 2 SO 4 1, 2 16 mm ø COD HR b) mg/l Dichromate / H 2 SO 4 1, 2 16 mm ø Copper a) mg/l Biquinoline 4 24 mm ø mg/l mm o mg/l mm ø MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 50 Phone: / Fax:

52 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of Reagent/Quantity Part Number ClO 2 DPD No. 1 DPD No. 3 Tablet / 100 Tablet / 100 RT106-0BT RT108-0BT Glycine f) Tablet / 100 RT217-0 Chlorine Reagent Set # Tablet / 100 each RS1060 ClO 2 DPD Free Chlorine Reagent Powder Pack / 100 RP010-0 Glycine f) Tablet / 100 RT217-0 Chlorine Reagent Set Powder Pack / Tablet RS0100 Cr Persulfate Reagent Powder Pack / 100 RP730-0 Chromium (Hexavalent) Powder Pack /100 RP731-0 Chromium Reagent Set Powder Pack / 100 RS7300 O 2 COD Reagent Tube test / 25 Tube test / 150 TT20720 TT20725 COD Reagent, Mercury Free Tube Test / 25 TT20710 O 2 COD Reagent Tube test / 25 Tube Test / 150 TT20721 TT20726 COD Reagent, Mercury Free Tube test / 25 TT20711 Tube Test / 150 TT20716 Reagents O 2 COD Reagent Tube test / 25 Tube test / 150 TT20722 TT20727 COD Reagent, Mercury Free Tube test / 25 TT20712 Cu Copper No. 1 Tablet / 100 RT355-0 Copper No. 2 Tablet / 100 RT356-0 Copper Reagent Set Tablet / 100 RS3550 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

53 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell SC400 MC500 SP600 Copper, (Free) mg/l Bicinchoninate 24 mm ø Cyanide mg/l Pyridine-Barbituric Acid 1 24 mm ø mg/l mm o Cyanuric Acid mg/l i) Melamine 24 mm ø DEHA µg/l PPST 3 24 mm ø DEHA µg/l PPST 3 24 mm ø Formaldehyde 1-5 mg/l H 2 SO 4 / 10 mm o mg/l Chromotropic Acid 50 mm o Formaldehyde mg/l H 2 SO 4 / 16 mm ø Chromotropic Acid Fluoride mg/l SPADNS 2 24 mm ø mg/l Hardness, Calcium mg/l Murexide 4 24 mm ø Hardness,Total 2-50 mg/l Metallphthalein 3 24 mm ø mg/l i) mg/l i) Hazen (Pt-units ; APHA) mg/l Direct Reading 1, 2 24 mm ø mg/l mm o MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 52 Phone: / Fax:

54 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of Reagent/Quantity Part Number Cu Copper Reagent Powder Pack / 100 RP030-0 CN Cyanide Reagent Test - Cyanide 11/12/13 Reagent test (Powder, L Liquid reagent) / 200 tests Cys Cyanuric Acid Tablet / 100 RT132-0BT DEHA DEHA Solution Liquid reagent / 100 ml L DEHA Tablet / 100 RT322-0 DEHA Reagent Set Tablet, Liquid / 100 RS3220 DEHA DEHA Reagent Set Powder Pack, Liquid / ~200 RS6000 HCHO Formaldehyde Reagent Set d) Reagent test / L approx. 75 tests HCHO Formaldehyde Tube Test d) Tube test / 25 L F SPADNS Reagent Liquid reagent / 250 ml L Fluoride Standard Solution / 16 oz R Reagent solution and standard required Reagents CaCO 3 Calcheck Tablet / 100 RT565-0 CaCO 3 Hardcheck P / Total Hardness Tablet / 100 RT566-0 Pt-units no reagents required - - a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

55 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell SC400 MC500 Hydrazine mg/l Dimethylamino- 24 mm ø Benzaldehyde 3 SP600 Hydrazine mg/l Dimethylamino- 24 mm ø mg/l Benzaldehyde 3 Hydrazine c) mg/l PDMAB 24 mm ø Hydrongen Peroxide mg/l mg/l DPD/Catalyst 5 24 mm ø 24 mm ø mg/l mm o mg/l mm ø Iodine mg/l DPD 5 24 mm ø Iron (II, III) (Soluble) mg/l mg/l i) PPST 3 24 mm ø 24 mm ø mg/l mm o mg/l mm o mg/l mm ø Iron (II, III) mg/l ,10-Phenanthroline 2 24 mm ø (Soluble) mg/l mg/l Iron g) mg/l TPTZ g) 24 mm ø (Total) mg/l mg/l Lead (Pb 2+ ) mg/l (2-Pyridylazo)-Resorcin 10 mm o Lead (Pb 2+ ) mg/l (2-Pyridylazo)-Resorcin 16 mm ø Manganese mg/l Formaldoxime 24 mm ø mg/l MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 54 Phone: / Fax:

56 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of Reagent/Quantity Part Number N 2 H 4 Hydrazine Test Powder Powder / 30 g L Spoon L Hydrazine Reagent Set Powder / 100 RS2910 N 2 H 4 Hydrazine Reagent Solution Liquid / 100 ml L N 2 H 4 Hydrazine Reagent Ampoules / 30 L H 2 O 2 Hydrogen Peroxide LR Tablet / 100 RT238-0 I DPD No. 1 Tablet / 100 RT106-0BT Fe Iron LR Tablet / 100 RT537-0 Iron (II) LR Tablet / 100 RT542-0 Iron Reagent Set Tablet / 100 RS5370 Fe Iron Ferro Reagent Powder Pack / 100 RP056-0 Reagents Fe Iron TPTZ Reagent Powder Pack / 100 RP055-0 Pb Lead Reagent Set d) Reagent test / 50 tests L Pb Lead Tube Test d) Tube test / 25 L Mn Manganese LR No. 1 Tablet / 100 RT608-0 Manganese LR No. 2 Tablet / 100 RT609-0 Manganese Reagent Set # Tablet / 100 each RS6080 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

57 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell Manganese LR mg/l PAN 24 mm ø SC400 MC500 SP600 Manganese HR mg/l Periodate Oxidation 2 24 mm ø mg/l Molybdate 1-50 mg/l Thioglycolate 4 24 mm ø 1-30 mg/l Molybdate HR mg/l Mercaptoacetic Acid 24 mm ø Nickel mg/l Dimethylglyoxime 2, 3 50 mm o mg/l mm ø Nitrate 1-30 mg/l Chromotropic Acid 16 mm ø Nitrate mg/l ,6-Dimethylphenole 3 16 mm ø Nitrite mg/l N-(1-Naphthyl)- 24 mm ø mg/l Ethylenediamine 2,3 Nitrite mg/l Sulfanilic/ 1 16 mm ø mg/l Naphthylamine Nitrite LR mg/l Diazotation 24 mm ø Nitrogen b) mg/l ,6-Dimethylphenole 2,3 16 mm ø (Total) mg/l i) Nitrogen, LR b) mg/l Persulphate- 16 mm ø (Total) digestion method Nitrogen, HR b) mg/l Persulphate- 16 mm ø (Total) digestion method MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 56 Phone: / Fax:

58 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of reagent/quantity Part Number Mn Manganese LR Reagent Set Powder Pack, liquid / 50 RS5090 Rochelle Salt Solution h) 30 ml L Mn Manganese HR Reagent Set Powder Pack / 100 RS5100 MoO 4 Molybdate No.1 Tablet / 100 RT306-0 Molybdate No.2 Tablet / 100 RT307-0 Molybdate Reagent Set # Tablet / 100 RS3060 MoO 4 Molybdate HR Reagent Set Powder Pack / 100 RS5300 Ni Nickel Reagent Test Reagent test (Powder, L Liquid reagent) / 50 tests N Nitrate Tube Test Reagent Set Tube Test / Powder Pack RS5580 N Nitrate/Nitrate - N Tube Test Tube test L Liquid reagent / 24 N Nitrite LR Tablet / 100 RT231-0 Reagents N Nitrite/Nitrite-N Tube Test Tube test (Pulver) 24 L N Nitrite 3 Powder Pack / 100 RP098-0 N Nitrogen (Total) Tube Test Tube test (Powder, L Liquid reagent) / 24 N Total Nitrogen LR Reagent Set Digestion tubes / 50 RS5550 Powder Pack / 50 N Total Nitrogen HR Reagent Set Digestion tubes / 50 RS5560 Powder Pack / 50 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

59 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell Oxygen, Active mg/l DPD Oxygen, Dissolved c) µg/l Rhodazine D TM SC400 MC500 Ozone mg/ L DPD/Glycine 5 24 mm ø mg/l mm o SP600 Phenols mg/l Aminoantipyrine 1 24 mm ø PHMB (Biguanide) 2-60 mg/l Buffer/Indicator 24 mm ø Phosphate LR b) mg/l Phosphomolybdic acid/ 16 mm ø (Total) mg/l Ascorbic acid 2 Phosphate HR b) mg/l Phosphomolybdic acid/ 16 mm ø (Total) 5-60 mg/l Ascorbic acid 2 Phosphate LR, Ortho mg/l Phosphomolybdic acid/ 24 mm ø Ascorbic acid 2 Phosphate HR, Ortho mg/l Vanadomolybdate 2 24 mm ø 1-80 mg/l Phosphate, Ortho mg/l Ascorbic acid 2 24 mm ø Phosphate, Ortho mg/l Ascorbic acid 2 16 mm ø Phosphate-ortho 3-60 mg/l Vanadomolybdate 2 16 mm ø MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 58 Phone: / Fax:

60 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of Reagent/Quantity Part Number O 2 DPD No. 4 Tablet / 100 RT122-0BT O 2 Dissolved Oxygen Reagent Ampoules / 30 L O 3 DPD No. 1 DPD No. 3 Tablet / 100 Tablet / 100 RT106-0BT RT108-0 BT Glycine f) Tablet / 100 RT217-0 Chlorine Reagent Set # Tablet / 100 each RS1060 C 6 H 5 OH Phenol No. 1 Tablet / 100 RT595-0 Phenol No. 2 Tablet / 100 RT596-0 Phenol Reagent Set Tablet / 100 RS5950 PHMB PHMB Tablet / 100 RT610-0 P Phosphate (Total) Tube Test Tube test (Powder, L PO 4 Liquid reagent) / 24 P Phosphate (Total) Tube Test Tube test (Powder, L PO 4 Liquid reagent) / 24 PO 4 Phosphate No. 1 LR Tablet / 100 RT304-0 Phosphate No. 2 LR Tablet / 100 RT305-0 Reagents Phosphate, Ortho LR Reagent Set # 100 each RS3040 PO 4 Phosphate No. 1 HR Tablet / 100 RT581-0 Phosphate No. 2 HR Tablet / 100 RT582-0 Phosphate, Ortho HR Reagent Set # 100 each RS5810 PO 4 Phosphate 3 Reagent Powder Pack / 100 RP155-0 PO 4 Reactive Phosphorus Reagent Set (Tube test) Tube Test / 50 RS5200 Powder Pack / 50 PO 4 Ortho-Phosphate VM Tube Test Tube test / 24 L a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

61 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell SC400 MC500 Phosphate b) acid hydrolyzable: Acid digestion 16 mm ø acid hydrolyzable mg/l Ascorbic acid 2 and total mg/l total: Acid-/ 16 mm ø mg/l Persulphate digestion mg/l Ascorbic acid 2 SP600 Phosphate (Total) b) mg/l Acid-/ 16 mm ø Persulphate digestion mg/l Ascorbic acid 2 16 mm ø Phosphate, Ortho c) 5-40 mg/l Vandomolybdate 2 Phosphate, Ortho c) mg/l Stannous Chloride 2 ph value Bromcresol Purple 5 24 mm ø ph value Phenol Red 5 24 mm ø ph value Phenol Red 5 24 mm ø ph value Thymol Blue 5 24 mm ø Potassium mg/l Tetraphenylborate- 24 mm ø 1-10 mg/l Turbidity 4 24 mm ø Silica mg/l Silicomolybdate 2,3 24 mm ø mg/l Silica LR mg/l Heteropolyblue 2 24 mm ø Silica HR 1-90 mg/l Silicomolybdate 2,3 24 mm ø mg/ L mm ø MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 60 Phone: / Fax:

62 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of reagent/quantity Part Number Total & Acid Hydrolysable Tube Test / 50 RS5250 P Phosphorous Reagent Set Powder Pack / 50 PO 4 P PO 4 P Total Phosphate Reagent Set Tube Test / 50 RS5210 PO 4 PO 4 Phosphate (ortho) 1 Reagent Ampoules / 30 L PO 4 Phosphate (ortho) 2 Reagent Ampoules / 30 L ph Bromocresol Purple / Photometer Tablet / 100 RT570-0 ph Phenol Red / Photometer Tablet / 100 RT177-0BT ph Phenol Red Solution Liquid reagent / 15 ml L ph Thymol Blue / Photometer Tablet / 100 RT571-0 Reagents K Potassium T Tablet / 100 RT567-0 SiO 2 Silica No. 1 Silica No.2 Tablet / 100 Tablet / 100 RT313-0 RT314-0 Silica PR (in presence of phosphate) Tablet / 100 RT315-0 Silica Reagent Set # Tablet / 100 each RS3130 SiO 2 Silica LR Reagent Set Powder Pack / 100 RS5690 Liquid reagent / 50 ml SiO 2 Silica HR Reagent Set Powder Pack / 100 RS5700 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

63 Reagents By Parameter Wave lengths λ / nm Test Range Method Sample Cell SC400 MC500 Spectral 0-50 m Direct reading 1 50 mm o Absorption-coefficient ISO 7887: Sulfate mg/l Bariumc Sulfate- 24 mm ø mg/l Turbidity 2 Sulfate mg/l Barium Sulfate- 24 mm ø Turbidity 2 Sulfide mg/l DPD/Catalyst 3, 4 24 mm ø SP600 Sulfite mg/l DTNB 24 mm ø mg/l mm o mg/l mm ø Surfactants (anionic) mg/l Methylene Blue 1 16 mm ø TOC b) mg/l H 2 SO 4 / Indicator 16 mm ø Turbidity Attenuated Radiation 50 mm o Method Urea mg/l Urease / Indophenol 24 mm ø mg/l Zinc mg/l Zincon 3 /EDTA 24 mm ø mg/l MSDS (Material Safety Data Sheets): Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 62 Phone: / Fax:

64 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Display Reagent Form of reagent/quantity Part Number - no reagents required - - SO 4 Sulfate 4 Reagent Powder Pack / 100 RP216-0 SO 4 Sulfate Turbidity Tablet / 100 RT545-0 S Sulfide No. 1 Tablet / 100 RT293-0 Sulfide No. 2 Tablet / 100 RT294-0 SO 3 Sulfite LR Tablet / 100 RT802-0 MBAS Tenside (Anionic) Tube Test d) Tube test / 25 L TOC TOC Tube Test d) Tube test / 25 L Aluminum screwcaps / 6 pc. L FAU no reagents required - - Reagents CH 4 N 2 O Urea Reagent 1 Liquid reagent / 15 ml L Urea Reagent 2 Liquid reagent / 10 ml L Ammonia No. 1 Tablet / 100 RT258-0 Ammonia No. 2 Tablet / 100 RT259-0 Urea Reagent Set # each 100 RS9300 Zn Copper/Zinc LR Tablet / 100 RT262-0 EDTA Tablet / 100 RT239-0 Dechlor (in case of zinc in presence of chlorine) Tablet / 100 RT235-0 Zinc Reagent Set Tablet / 100 RS2620 a) determination of free, combined and total b) Reactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MC500: Adapter is necessary for Vacu-vials (Order code L192075) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of chlorine dioxide / ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution # no BT blister tablets, including stirring rod, 10 cm

65 TR125 Thermoreactor Highlights Easy to use 24 hole capacity Continuous operation timer with automatic turn-off function Overheating protection 64 Phone: / Fax:

66 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL First Edition 65 The TR125 Thermoreactor is for chemical digestion of samples that require it, such as in the determination of COD, TOC, Total Phosphate and Total Nitrogen. The required temperatures and reaction times are pre-programmed, and easy to select by using the keypad. Users can pre-select reaction times of 30, 60 and 120 minutes or can set it to operate continuously. When digestion is complete, the reactor automatically turns off and will sounds an alarm. The Chemical Oxygen Demand (COD) test is widely used as a measure of organic contamination by determing the quantity of oxygen required for oxidation of reduced species including organic matter, in a water sample using a specific oxidizing agent, temperature and time reduction. COD testing is more reliable and is preferred to BOD testing as test results are more reproducible and are ready in two hours (or less) rather than 5 days. In addition, COD testing is a better indicator of organic pollutants in industrial wastewater containing cyanides and heavy metals. COD testing affords rapid response to changing conditions before critical problems develop. The TR125 COD reactor is fitted with 24 holes for 16 mm diameter vials. Specifications Housing Round metal block in epoxy covered housing, 24 holes 16 mm diameter Front Robust membrane keypad with 4 keypad keys Temperature 70/100/120/150 C settings 158/212/248/302 F ± 0.3 C Timer Heating Prep. time Power supply Weight 30, 60, and 120 minutes with continuous operation, automatic turn-off with alarm 400 Watts electronically controlled, with overheating protection approx. 10 minutes 230 V/115 V/50-60 Hz 7.9 pounds Dimensions x 6.10 x 3.74 inches (L x W x H) Certification CE TR125 Thermoreactor Part Number TR12500 SC400-01S Description TR125 Reactor, 24 Tube Capacity SC400 COD Set, see page 31 for more information

67 TB200 Portable Turbidimeter Highlights Simple to use Easy to Calibrate Auto-ranging Features Durable Ideal for regulatory monitoring 66 Phone: / Fax:

68 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The TB200 TM Portable Turbidimeter from Orbeco-Hellige, Inc. This instrument allows fast and easy turbidity measurement in both the field and in the laboratory. Using a white light source and 90 o detection, the TB200 meets the USEPA specifications for turbidity measurement (EPA Standard 180.1). Also available in an Infrared version, the TB200-IR is ISO 7027 compliant. The instrument features an auto-ranging function that automatically selects the correct turbidity range for your sample. Calibration is simple with the included calibration standards. A power efficient microcircuit design allows the instrument to yield 5,000 tests on 4-AA alkaline batteries with an estimated 7 to 10 year bulb life. Integrated diagnostics confirm proper operation and accuracy. The instrument comes with all required items for testing including the TB200 Turbidimeter, two sample cells, batteries, calibration set, operator s manual, and carrying case. Specifications Range Resolution Auto Ranging from NTU 0.01 NTU < 100 NTU 0.1 NTU < NTU 1 NTU < NTU Accuracy (0-500 NTU) ± 2% of reading or ± 0.01 NTU ( NTU) ± 3% of reading Response Time Power Supply 14 Seconds 4-AA Batteries Dimensions 8.25 x 3.75 x 7.75 inches (L x W x H) Display 4 Digit (7segment) LCD Insulation Pollution Degree 2 Rating Operating 0 C 50 C (32 F 122 F) Temperature Range Sample 0 C 50 C (32 F 122 F) Temperature Range Principle of Operation Nephelometric Light Source TB200: Tungsten Lamp TB200-IR: (860 nm) LED Sample Cells 10 ml Conformance TB200: USEPA Method TB200-IR: ISO 7027 Certification CE TB200 Portable Turbidimeter Part Number TB TB200IR-10 TB TB Description TB200 Portable Turbidimeter TB200-IR Infrared Portable Turbidimeter Sample Cells, 3 pack Calibration Set: 0.02, 10.0 & 1000 NTU

69 TB300-IR Lab Turbidimeter Highlights Auto-ranging Data Logging Waterproof Real-time Clock 68 Phone: / Fax:

70 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The TB300-IR TM Lab Turbidimeter from Orbeco-Hellige, Inc. This instrument is designed for quick and easy turbidity measurement in the laboratory. Using an infrared (IR) light source and 90 o detection, the TB300-IR conforms with ISO 7027 specifications for turbidity measurement of colored and color-free samples. The auto-ranging function automatically selects the correct range for turbidity measurement from 0.01 to 1100 NTU. The data-logging feature enables the user to store up to 1,000 data sets with the date, time, and registration number. The instrument is power efficient, and users can choose to operate the instrument on 7 NiCd rechargable batteries or with a wall plug adapter. The TB300-IR Lab Turbidimeter comes complete with all of the items necessary for testing including the TB300-IR Lab Turbidimeter, two sample cells, batteries, calibration set, operator s manual, and carrying case. Specifications Principle Light source Keypad nephelometric (90 scattered light) IR-LED (860 nm) conditional acid and solvent resistant; membrane switch keypad with audible feedback Auto Off automatic switch off approx. 20 minutes after last key pressed Display Graphic-Display Update Software update via Internet Clock real time clock Data 1000 data sets with date, time logging and registration number Sample approx. 12 ml volume Range NTU (Auto range) Resolution 0.01 from (NTU) 0.1 NTU from NTU from Accuracy Ambient conditions Interface Power supply Weight (instrument) ± 2 % of reading (0-500 NTU) ± 5 % of reading ( NTU) temperature: 5-40 C F 30-90% relative humidity (non condensing) RS-232 for printer and PCconnection; 9-pin D-sub-mail connector; data format ASCII 7 NiCd rechargeable batteries (Type AA/Mignon with 1100mAh); wall plug mains adapter (Input: V, 50-60Hz; Output: 15V;530mA) and Lithium battery CR 2032, 3V) for data storage and real time clock. approx pounds including batteries and power pack approx x 7.67 x 2.76 inches Dimensions (L x W x H) Conformance meets ISO 7027 Certification CE TB200 TB300 Portable Lab Turbidimeter Part Number Description TB300IR-10 TB300-IR Infrared Lab Turbidimeter TB300IR-50 Sample Vials for TB300-IR, set of 12 TB300IR-60 Standard Set for TB300-IR (0.1, 20, 200, 800 NTU

71 Oxi700 BOD System Highlights Direct Sample Selection Automatic Storage of all values Easy to use Accurate and direct display of BOD values in mg/l Automatic start after temperature equalization Mercury-free Inductive stirring system with automatic re-centering of stirring rods 70 Phone: / Fax:

72 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The Oxi700 BOD System is a manometric respirometer that measures Biological Oxygen Demand according to Standard Methods 5210 D. The system includes: Complete unit with 6 sensor heads and control unit with batteries Inductive stirring unit with power supply 6 sample bottles 6 rubber gaskets 6 magnetic stirring rods, 1 overflow flask (157 ml) 1 overflow flask (428 ml) 1 bottle of potassium hydroxide solution (50 ml) 1 bottle of nitrification inhibitor solution (50mL) Instructions The Orbeco-Hellige sensor system is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. The integral pressure sensors,make it unnecessary to use mercury for pressure measurements. Measuring ranges and sample volumes The BOD level of a sample depends on the quantity of organic matter present, which can vary considerably. The Orbeco- Hellige Oxi700 is calibrated for the various sample volumes and the corresponding measuring ranges listed in the table below. The overall measuring range of the system is mg/l. For all measuring ranges, BOD is shown directly in mg/l. O 2 CO 2 Pressure Sensor Seal cup Sample Bottle Waster Water Gas Phase How it Works Respirometric methods provide direct measurements of the oxygen consumed by microorganisms from an air or oxygen-enriched environment in a closed vessel under conditions of constant temperature and agitation. Carbon dioxide produced metabolically by the bacteria is chemically bound by the potassium hydroxide solution contained in the seal cup in the bottle. The result is a pressure drop in the system, which is directly proportional to the BOD value and is measured by the Orbeco-Hellige BOD sensor. The BOD level is then displayed directly in mg/l. The BOD values are stored in the sensor memory and can be viewed on the large-format display at any time without the need for time consuming conversion using factors. This means that test series that end on a weeknd can be evaluated during the following week. The measurement period is userselectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days and manometric determination of OECD, for example, generally takes place over a period of 28 days. Oxi700 BOD System Range mg / L BOD Sample Volume ml

73 Oxi700 BOD System Temperature equalization Temperature equalization is essential prior to biological testing, as temperature has a major effect on biological activity. BOD measurements, for example, are always performed in a thermostatically controlled cabinet at a temperature of 20 C. Automatic start function Variations in sample temperature prior to testing result in pressure variations within the measuring system during the temperature equalization period in the thermostatically controlled cabinet (if BOD measurement is to take place at 20 C, for example). Such variations would normally cause errors during manometric measurement. In order to prevent such errors, the OXi700 BOD meter is equipped with an automatic start feature: measurement does not start until the temperature in the samples is the same as that in the thermostatically controlled cabinet. This rules out the possibility of temperature (and pressure) fluctuations that are not related to the manometric measurement Start Day 1 Day Day 1 Day 2 Day 3 Day 4 Day 5 Day 2 Day 3 Day 4 Day 5 Display 150 mg / l 220 mg / l 240 mg / l 250 mg / l 260 mg / l Evaluation of measurements If the measuring period is set at 24 hours, the Oxi700 BOD measuring system records a measurement once every hour. With a measuring period of 48 hours, the unit measures and stores a BOD value once every 2 hours. If the measuring period is between 3 and 28 days, one value is measured and stored each day. Current values and stored values may be called up at any time. The table/below illustrates an example of BOD 5 evaluation. The development of BOD over a period of 5 days is easily seen. Specifications Meas. principle Manometric; mercuryfree; electronic pressure sensor Ranges 0-40, 0-80, 0-200, [mg/l O 2 ] 0-400, 0-800, , mg/l Accuracy* 0.5 % full scale at 20 C (68 F) Applications BOD 5, BOD 7, OECD 301 F... Result BOD [mg/l]; 4 - digits; display 7 - segment LED Measurement BOD-range, parameter volume, duration, time of display measurement Measurement User-selectable, between period 1 and 28 days Auto result storage Storage interval Automatic start Up to 28 results, depending on measurement period hourly (1 day); every 2 hours (2 days); daily (3-28 days) - After temperature equalization of samples Power 3 alkaline-manganese supply batteries (size C) Battery life 1 year (normal use as BOD 5 meter max. one reading a day); early warning before battery fails Interface Clock Protection RS 232 for printer or PC connection Real-time clock IP 54 (sensor head) Dimensions: x 7.67 x 9.05 inches (L x W x H) including stirring unit Weight Housing Approval 8.5 lbs., unit with bottles lbs, complete with stirring unit ABS CE *No standard is available to check the accuracy of respirometric oxygen uptake measurement. Tests with a glucose-glutamic acid solution having a known theoretical BOD have shown that the variation is approximately 5% in the range of 50 to 100 mg/l BOD, and 3% for higher range. Minimum Response or sensitivity of respirometric systems is about 0.05 to 1 mg/l Phone: / Fax:

74 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Part Number Description L L L L Oxi700 BOD System (115 V / 230V, Hz) See page 71 for complete deatils. Oxi700 BOD System, with 12 sensor heads Sensor head BOD sample bottle Brown glass, 500 ml L BOD sample bottles, Brown glass, 500 ml, set of 6 bottles L Cable for connection to a PC serial 9-pins L Inductive stirring system for 6 samples, V / Hz L Stirring rod L Stirring rod remover L Rubber gasket Chemicals: L Potassium hydroxide solution 45 % L Nitrification inhibitor (N-ATH), 50 ml L Overflow flask, 21.7 ml L Overflow flask, 56 ml L Overflow flask, 94 ml L Overflow flask, 157 ml L Overflow flask, 244 ml L Overflow flask, 360 ml L Overflow flask, 428 ml L Complete set Overflow flasks L Test set, BOD CM test tablets, box with 8 tablets The Orbeco-Hellige microprocessorcontrolled inductive stirring system is non-wearing and maintenance-free. At regular intervals, the magnetic stirring rods are accelerated to the maximum speed, and then decelerates. This ensures the centralization of the stirring rods. Stirring rods that move away from the center of the bottle are re-centered quickly and reliably. The inductive actuation system guarantees maintenance-free operation. Oxi700 BOD System Advantages Maintenance-free and non-wearing Regular change in stirring speed Automatic centering of stirring rods No mechanical components in the stirring system In addition to the BOD unit for measurement and storage of BOD levels, the Orbeco-Hellige Oxi700 BOD measuring system includes sample bottles, measuring sensors, non-wearing inductive stirring system, overflow measuring flasks for monitoring of sample volumes, nitrification inhibitor and potassium hydroxide as an absorbent.

75 Series 200 Electrochemistry Instruments 74 Phone: / Fax:

76 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The Series 200 Electrochemistry instruments are rugged, high performance handheld meters that are specifically designed for use in both the laboratory and the field. The meters come standard with the following features: Waterproof housing with built-in storage compartment for probes. A built-in support arm can be flipped up to hang the meter on pipes or branches. A simple user interface, outlining the required configuration options for all three systems, facilitates meter operation both outdoors and in the laboratory ph 200 ph / redox measurement and temperature measurement (Pt1000 or NTC 30kOhm) Automatic temperature compensation (ATC) Auto Hold function Internal memory for 20 data sets Automatic buffer recognition with Tintometer standard or DIN or individual buffer 1, 2 and 3 point calibration Low battery and battery change indicator Sensor evaluation in the display based on the calibration result (from 10 to 100%) Battery operation period up to 15,000 hours Shock-absorbing rubber protective housing Waterproof Cond 200 Conductivity, Total Dissolved Solids (TDS), Salinity and Temperature measurement Dirt-insensitive up-to-date 4-pole conductivity cell offering highest precision Automatic temperature compensation (ATC) Min/Max value storage Internal memory for 20 data sets Linear and non-linear temperature compensation (EN27888) Calibration against standard solutions Low battery and battery change indicator Shock-absorbing rubber protective housing Battery operation period up to 3,000 hours Waterproof Electrodes / Measuring Probes The wide variety of high-quality electrodes and measuring probes for the Series 200 meters makes them suitable for almost any application in water analysis, industry and research. ph combination electrodes made of glass and plastic, with a gel or liquid electrolyte, as well as various temperature sensors (NTC 30kOhm, Pt1000) are considered standard for ph meters. Redox electrodes made of plastic with gel electrolyte and platinum tip have a long life and are easy to use. The galvanic, membrane-covered oxygen sensor with built-in temperature sensor allows instant measurement without the need for time-consuming polarization. The sturdy, dirt-insensitive 4-pole conductivity measuring cell with graphite electrodes is ideal for use in industrial process and waste water analysis. The temperature range from 0 to 80 C (32 to 176 o F), for a short period up to 100 C, (212 o F) make this sensor to a practice-oriented, user friendly item. The automatic Hold function "freezes" stable measuring data in the display and indicates the presence of stable and reproducible results. The internal memory allows storage of 20 data sets to facilitate subsequent evaluation. The integral automatic switch-off feature, varying from 1 to 120 minutes, increases the operating life of the units. The power consumption of all three units has been reduced to a minimum. As a result, the 4 x 1.5 V integrated batteries have an operating life of up to 15,000 hours, depending on the unit version. DO 200 Oxygen partial pressure, Oxygen concentration, Oxygen saturation, Temperature measurement Automatic absolute air pressure measurement Auto Hold function Easy calibration against oxygen in air Salinity correction Self-polarizing galvanic oxygen probe, allows instant measurement after the system is switched on Low battery and battery change indicator Sensor evaluation in the display Accessories for depth measurement Battery operation period up to 12,000 hours Shock-absorbing rubber protective housing Waterproof Series 200 Electrochemistry Instruments

77 Series 200 Model ph 200 Model Cond 200 Specifications Specifications ph 0.00 to Accuracy ± 0.01 ph (at nominal temperature, unit ± 1 digit) Temperature to C 14.0 to F Accuracy ±32.36 F (32 to 122 F), otherwise ± F Redox (ORP) to mv Relative Redox to Rel mv (based on DIN ) Accuracy ± 0.1 % FS (mv or Rel mv) Sensor DIN and connections two 4 mm banana sockets "Temp and "Ref Input resistance >1012 Ohm (typ.) Input current <1 pa Nominal 77 F temperature Operating 32 to +122 F temperature Storage -4 to +158 F temperature Power supply 4 x 1.5V battery, type AA Operating time up to >15,000h Power 0.2 ma consumption Auto-Off minutes Calibration 1-, 2- or 3-point calibration with auto buffer recognition Orbeco-Hellige buffer, DIN buffer or user-selectable buffer Certification CE Ordering Information Model ph 200 L Model ph 200, without electrode, with batteries, instruction manual, lanyard, case L Model ph 200 (SET 1) instrument, batteries, ph/temp. plastic-electrode type 230, ph-buffer-set (ph 4.00/7.00/10.00), in case, manual, guarantee sheet L Model ph 200 (SET 2) as SET1, but with ph/temp. plasticelectrode type 225, and temperature sensor Pt 1000, manual, guarantee sheet Accessories Model ph200 L ph-electrode plastic/gel-type 225 L ph/temp.-electrode type 230 plastic/gel/temperature NTC30kOhm L ph-electrode glass/gel-type 235 L Redox-electrode plastic-type 240 L Temperature sensor, PT1000 L KCl-solution, 3 molar saturated with AgCl, 100 ml L ph buffer-set 4.00/7.00/10.00 (25 C) L ph buffer 4.00 (75 F) 1 liter L ph buffer 7.00 (75 F) 1 liter L ph buffer (75 F) 1 liter L Adapter cable DIN BNC L Adapter cable DIN19262, S7 plug-head L Lanyard, Series 200 L Case, Series 200 Conductivity 0.0 to µs/cm 0 to 2000 µs/cm 0.00 to ms/cm 0.0 to ms/cm Resistance to kohm*cm TDS 0 to 1999 mg/l Salinity 0.0 to 70.0 g/kg Accuracy ± 0.5 % v. MW ± 0.5 % FS (± 3 digits) Temperature -5.0 to C 23.0 to 212 F Accuracy ±0.3K Cell constant 0.50 ± 0.10 cm-1 Temperature compensation selectable: - linear, 0.3 to 3.0 %/K - non-linear in acc. with EN no compensation Reference 68 F and 122 F temperature Calibration 1-point calibration in the range from 1000 to 2000 µs/cm Nominal 75 F temperature Operating Unit: 89.6 to +122 F temperature Measuring cell: 23 to 176 F (up to 212 F for short periods) Power supply 4 x 1.5 V battery, Type AA Operating time up to 1500 h Power ca. 2 ma, max. 4.2 ma consumption Auto-Off minutes Measuring cell 4-pole conductivity measuring cell with integrated temperaturesensor (NTC10kOhm). Electrode material: special graphite Shaft material: epoxy Temperature sensor: stainless steel Dimensions: diameter 12 mm, 120 mm long Certification CE 76 Phone: / Fax:

78 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL Model DO 200 Specifications Ordering Information Model DO 200 Ordering Information Model Cond 200 L Model Cond 200 with, batteries, 4-electrode conductivity cell, case, manual, guarantee sheet Accessories Cond200 Code Article L Electode Conductivity Cell L Calibration solution 1413µS/cm L Lanyard, Series 200 L Case, Series 200 O 2 partial pressure O 2 concentration 0.0 to hpa, 0 to 1200 hpa 0.0 to mm Hg, 0 to 900 mm Hg 0.00 to mg/l, 0.0 to 70.0 mg/l O 2 saturation 0.0 to %, 0 to 600 % Accuracy ± 1.5% ± 0.2 mg/l (0 to 25 mg/l) ± 2.5% ± 0.3 mg/l (25 to 70 mg/l) ±1Digit Temperature -5.0 to C 23.0 to F Accuracy ± 32 F Abs. air pressure Accuracy 500 to 1100 hpa ± 0.5% full scale Nominal 77 F temperature Operating 32 to +122 F temperature Storage -4 to +158 F temperature Power supply 4 x 1.5 V battery, Type AA Operating time up to h Power max ma consumption Auto-Off function minutes Dimensions 6.89 x 5.52 x 1.77 inches (L x W x H) Weight approx lbs. Electrode Self-polarising oxygen electrode with integrated NTC sensor Connection: 7-pin DIN socket Installation diameter: 12.0 ± 0.2 mm Overall length: approx. 220 mm (incl. kink protection) Operating temperature: 32 to 104 F Certification CE L Model DO 200 with batteries, oxygen sensor (1.5 m cable), electrolyte (KOH), 3 interchangeable membrane heads, case, manual, guarantee sheet L Model DO 200 as above, but with oxygen sensor 10 m cable L Model DO 200 as above, but with oxygen sensor 30 m cable Accessories Oxi200 L Oxygen sensor, 1.5 m cable L Oxygen sensor, 10 m cable L Oxygen sensor, 30 m cable L Service Set Oxygen sensor 3 interchangeable membrane heads, 100 ml plastic bottle KOH-solution 3 mol/l L Protection cap for depth measurement L Lanyard, Series 200 L Case, Series 200 Series 200 Electrochemistry Instruments

79 Floc Testers Highlights Continuous variable stirring speed Digital display Height adjustment of the stirring rods Timer 78 Phone: / Fax:

80 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL ET 740 (Laboratory) Stirring places four Stirring speed revolutions control per minute Resolution 1 revolution Timer minutes or 0-99 hours (continuous ) Power supply 115 V or 230 V Hz Weight approx lbs. Dimensions 25.4 x 13.7 x (L x W x H) inches Certification CE Model Number L ET 750 ( Laboratory) Flocculation testers are designed for a range of applications such as testing the efficiency of flocculation or precipitation agents. The ET 740 model with 4 stirring places and the ET 750 model with 6 stirring places are designed for laboratory use and are are equipped with an illuminated back panel for glare-free observation of the samples. Other features include: Continuously variable stirring speed Digital display of stirring RPM Timer function Illuminated back panel Height adjustment option for the stirring blades during operation. The ET 740 and ET 750 require 1500 ml beakers of low or high form. The beakers are not included. The flocculation tester ET 730 with 4 stirring places is primarily designed for field use. The 4 stirring points are arranged in a circle around a lamp making it easier to observe the flocculation process. State-of-the-art technology ensures maximum operating convenience and makes the unit maintenance-free. ET 730 requires 1000 ml beakers of low form. The beakers are not included. Stirring places six Stirring speed revolutions control per minute Resolution 1 revolution Timer minutes or 0-99 hours (continuous) Power supply 115 V or 230 V Hz Weight approx lbs. Dimensions 36.8 x 13.7 x (L x W x H) inches Certification CE Model Number L Floc-Testers ET 730 (Portable) Stirring places four Stirring speed control revolutions per minute Timer 1-30 minutes (continuous) Power supply 100 V V Hz Weight approx lbs. Dimensions 9.84 x 12.6 x 9.84 inches (L x W x H) Certification CE Model Number L

81 Pool and Spa Taking care of a Pool or Spa using Orbeco-Hellige s full line of pool testing products has never been quicker or easier! For over 40 years, Orbeco-Hellige and our sister companies have been manufacturing Pool and Spa testing kits that are used around the world. Our products are used to help keep pools in private homes, hotels, and those for commercial use sparkling and safe. We offer a full spectrum of pool testing products - from our easy to use visual systems to our new highly accurate Scuba TM Electronic Pool Tester and the advanced PC (Pool Control) line of water testing instruments. Each kit comes complete with everything needed to obtain easy, fast, and accurate results Phone: / Fax:

82 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL PC3 IN 1 The PC3 IN 1 is a reliable entry level photometer providing a simple but accurate means of testing Chlorine, ph, and Cyanuric Acid. Features and Benefits include: Waterproof Construction Data logging of up to 16 results Backlit LCD Display Scroll driven menu system Model Part Number LPC3 The LPC3 comes with 3 sample cells, crushing rod, 9V battery, enough reagents fro 100 tests of each parameter, and carrying case. Parameter Chlorine, Free Chlorine, Total ph-value Cyanuric Acid Range mg/l mg/l ph mg/l PC6 IN 1 The PC6 IN 1 is Orbeco-Hellige s midrange photometer providing an accurate means of testing pool water. Features and Benefits include: Robust Construction Backlit LCD Display Scroll driven menu system Model Part Number LPC6 The LPC6 comes with 3 sample cells, crushing rod, battery, enough reagents for 100 tests of each parameter, and carrying case. Parameter Chlorine, Free Chlorine, Total Bromine Alkalinity, Total-M ph-value Calcium Hardness Cyanuric Acid Range mg/l mg/l mg/l mg/l ph mg/l mg/l Pool and Spa Products PC9 IN 1 The PC9 IN 1 offers signifigantly more than any photometer in its class. Features and Benefits include: Parameter Range Balanced water calculator Chlorine, Free (Langelier Index) Chlorine, Total Storage of 1000 results Bromine Computer or printer connectivity Alkalinity, Total-M ph-value AC or Battery Power Calcium Hardness Single button test selection Ozone Copper Model Part Number LPC9 Cyanuric Acid The LPC9 comes with 3 sample cells, crushing rod, batteries, 120V AC power adapter, enough reagents for 100 tests of each parameter, and carrying case mg/l mg/l mg/l mg/l ph mg/l mg/l mg/l mg/l

83 Scuba Series The Next Generation in Electronic Pooltesters Highlights Highly Accurate Portable Waterproof - and it floats! Digital Display Quick-Dissolving Reagent Tablet with 5 year Shelf Life! Integrated Sample Chamber - No Sample Cell to lose or break! Auto-off Hi/Low if results are out of range 82 Phone: / Fax:

84 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL The Scuba TM is an electronic, state-of-the-art pool tester. A sample of the water is examined using colorimetric methods and the results are shown in the high-precision digital display. The unit has a rugged housing designed to be easy to hold (even with wet hands!) and is, of course, fully waterproof. The Scuba is available in two different versions, Scuba and Scuba+. Both instruments test for Free and Total Chlorine, ph, and Cyanuric Acid. The Scuba+ has the capability of also testing Alkalinity and Bromine. The Scuba is supplied complete with specially formulated, quick-dissolving reagent tablets identified by their white foil packaging. It also has a convenient strap, so it can be safely hung in a storage area. Easy 6-Step Operation: 1. Insert the 9V battery into the Scuba and turn it on. 2. Push the Mode button to select the required test. 3. Open the cover on the left hand side of the instrument, and swing the Scuba through the water until the sample chamber is full. 4. Close the cover and press the Zero / Test button to set the zero. 5. Open the cover, add the appropriate tablet, close the cover and gently shake the instrument to dissolve the tablet. 6. Press the Zero / Test button once more, and the display will digitally show the results in mg/l or as ph units. Pool and Spa Products Parameter Scuba Scuba+ Scuba-Alk Range Resolution Replacement Accuracy Reagent Free Chlorine p p p 0-6 mg/l 0.01 mg/l LP * Total Chlorine p p p 0-6 mg / L 0.01 mg / L LP * Bromine p 0-13mg / L 0.01 mg / L LP ** ph p p p ph 0.01 mg / L LP ± 0.2 Cyanuric acid p p mg / L 1.00 mg / L LP ± 10 mg/l Alkalinity p p mg / L 1.00 mg / L LP ±50 mg/l Ordering Information Scuba LP Scuba+ LP Scuba-Alk LP of each test for Scuba LP of each test for Scuba+ LP * 0-1 mg/l ± 0.2 mg/l; 1-2 mg/l ± 0.3 mg/l; 2-3 mg/l ± 0.4 mg/l; 3-6 mg/l ± 0.5 mg/l ** 0-2 mg/l ± 0.5 mg/l; 2-4 mg/l ± 0.7 mg/l; 4-7 mg/l ± 0.9 mg/l; 7-13 mg/l ± 1.2 mg/l

85 MINITESTER THREE-CHAMBER-Tester POOLTESTER Item Chlorine-pH Chlorine mg/l ph value Code LP Item Free Chlorine / ph HR Chlorine mg/l ph value Code LP Item Chlorine-pH HR Chlorine mg/l ph value Code LP Replacement Reagent Bromine-pH Bromine 1 8 mg/l ph value Replacement Reagent LP LP LP Each MINITester includes enough reagents for 20 tests and multi-lingual instructions in a bubble pack. Pack contains 6 units. Replacement Reagent Bromine-pH Bromine mg/l ph value Replacement Reagent Biguanide (PHMB)-pH PHMB mg/l ph value LP LP LP LP Replacement Reagent LP in 1 LP Chlorine mg/l ph value Total Alkalinity mg/l Cyanuric Acid mg/l Calcium Hardness mg/l Replacement Reagent LP Replacement Reagent Bromine-pH Bromine mg/l ph value Replacement Reagent Copper (free)-ph Copper mg/l ph value Replacement Reagent LP LP LP LP LP Each POOLTESTER includes enough reagents for 20 tests and a multi-lingual instruction manual in a plastic box. Pack contains 12 units. Each THREE-CHAMBER-TESTER includes enough reagents for 20 tests and a multi-lingual instruction manual in a bubble pack. Pack contains 6 units Phone: / Fax:

86 Orbeco-Hellige, Inc Parkland Drive Sarasota, FL POOLCHECK Item Code 5 in 1 Kit LP56230 Chlorine mg / l, ph value Calcium Hardness mg/l Total Alkalinity mg/l Cyanuric Acid mg/l Replacement Reagent LP Each kit includes the POOLCHECK unit, accessories, reagents for 20 tests and a multi-lingual instruction manual packed into a plastic case. Pack contains 12 units. Refill Packs Item Code Chlorine / ph* LP DPD No. 1 / RAPID-tablets and 30 PHENOL RED / RAPID-tablets Bromine / ph* LP DPD No. 1 / RAPID-tablets and 30 PHENOL RED / RAPID-tablets Chlorine / Bromine - ph* LP DPD No. 1 / RAPID-tablets and 50 PHENOL RED / RAPID-tablets PHMB - ph* LP PHMB-tablets and 30 PHENOL RED / RAPID-tablets Copper (free) - ph* LP COPPER / ZINC-tablets and 20 DECHLOR-tablets 20 PHENOL RED / RAPID-tablets 5 in 1* LP DPD No. 1/ RAPID-, 20 PHENOL RED / RAPID-, 10 CALC-, 20 ALKACHECK- and 20 CYANURIC ACID-tablets Tablet Reagents Item Quantity Code DPD No.1 / RAPID 100 RT131-0BT 250 RT131-1BT 500 RT131-2BT DPD No.3 / RAPID RT129-0BT RT129-1BT 500 RT129-2BT DPD No.4 / RAPID RT157-0BT RT157-1BT 500 RT157-2BT PHENOL RED/RAPID 100 RT179-0BT 250 RT179-1BT 500 RT179-2BT Biguanide (PHMB) 100 RT RT589-1 also suitable for seawater Highlights Pool and Spa Products * Each pack contains 12 units. Orbeco-Hellige -RAPID tablets DPD and PHENOL RED will dissolve quickly, have a guaranteed 10 year shelf-life and are provided in green-printed aluminum foil.. Material Safety Data Sheets:

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water. Comparator 2000+ The system for colorimetric water analysis Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing

More information

AQUALYTIC. Parameter, Ranges and Reagents for. Chloride 530 Silver nitrate/turbidity mg/l Cl

AQUALYTIC. Parameter, Ranges and Reagents for. Chloride 530 Silver nitrate/turbidity mg/l Cl AQUALYTIC Parameter, Ranges and Reagents for Test λ a) / nm Method Range Display Alkalinity-m (total) 610 Acid/Indicator 1, 2 5-200 mg/l CaCO 3 Alkalinity-p 560 Acid/Indicator 1, 2 5-500 mg/l CaCO 3 Aluminium

More information

Comparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards

Comparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards Comparator 2000+ Colorimeter for regular testing in public pools & spas with colour-stable glass standards 24 www.lovibond.com Pool & Spa Water Testing - January 2013 Comparator 2000+ With its accessories,

More information

Specification and Certificate of Analysis

Specification and Certificate of Analysis Reagents Green chemistry For decades, the Tintometer Group has been known as a producer of reagents for water analysis, which are supplied under the brand name Lovibond. The wide range of applications

More information

Lovibond Water Testing. Tintometer Group. General Catalogue. General Catalogue. Instruments and Reagents for Today s Water Analysis.

Lovibond Water Testing. Tintometer Group. General Catalogue. General Catalogue. Instruments and Reagents for Today s Water Analysis. General Catalogue Lovibond Water Testing Tintometer Group General Catalogue Instruments and Reagents for Today s Water Analysis www.lovibond.com PHILOSOPHY Water is the basis of life. And it also provides

More information

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries Please visit our website at thermofisher.com/mastermethods for the latest instructions for Thermo

More information

Sustainability and environmental protection. Tintometer places great importance on sustainability and the sensitive use of natural resources.

Sustainability and environmental protection. Tintometer places great importance on sustainability and the sensitive use of natural resources. Tintometer -Group There are very few companies which can look back over a history of more than 125 years of success. The reason we can do so lies in the world-wide appreciation of our products and the

More information

DR 1900 PORTABLE SPECTROPHOTOMETER

DR 1900 PORTABLE SPECTROPHOTOMETER DR 1900 PORTABLE SPECTROPHOTOMETER Applications Drinking Water Wastewater Field Use Industrial Water Power Carry more water methods with you wherever you need them most. The DR 1900 combines the ruggedness

More information

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Page A2 A4 A6 A20 A1 Single Parameter Simple and Economical Analysis HANNA instruments test kits are the

More information

Photometer-System using Dual Beam Technology

Photometer-System using Dual Beam Technology Tintometer Photometer-System using Dual Beam Technology Dual Beam Technology and Interference Filters for best accuracy 44 Applications Waste Water Drinking Water Industrial Process Water Scientific Applications

More information

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside!

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside! Laboratory & Field Instruments: See Inside! Quick Reference Guide See pages 86-87. for Spectrophotometers and Colorimeters See pages 88-90. for Turbidimeters See pages 90. Pour-Thru See pages 91. Quick

More information

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

HI Multiparameter Photometers with up to 44 Measurement Methods.  ISO 9001:2000 Certified HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to 44 Measurement Methods ISO 9001:2000 Certified www.hannainst.com/usa HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to

More information

MC500 Multi-Parameter Colorimeter

MC500 Multi-Parameter Colorimeter MC500 Multi-Parameter Colorimeter Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Keep reagents out

More information

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Reliable water analysis Precise & Affordable A complete line of Spectrophotometers, Colorimeters and Turbidity

More information

DR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis

DR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis DR/800 Series Colorimeters High-Value, High-Capability Instruments for Water Quality Analysis DR/800 Series Colorimeters Hach DR/800 Series Colorimeters combine ease of use, multiple testing capabilities

More information

Available tests for the photometer MD600 / MaxiDirect New Tests

Available tests for the photometer MD600 / MaxiDirect New Tests Available tests for the photometer MD600 / MaxiDirect New s 20 Acid demand ph 4.3 T 610 Acid / Indicator 1, 2 0.1-4 mmol/l ALKA-M PHOTOMETER 513210BT 30 Alkalinity-m T (total) 610 Acid / Indicator 1, 2

More information

SP600. Spectrophotometer. Instruction Manual

SP600. Spectrophotometer. Instruction Manual SP600 Spectrophotometer Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the

More information

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers DelAgua Safe Water Reagent Identification Chart for Lovibond Tintometer photometers For Use: Identify the parameter required, ensure the parameter matches your photometer, codes required for the test are

More information

Thermo Scientific Orion AQUAfast AQ3700 Colorimeter

Thermo Scientific Orion AQUAfast AQ3700 Colorimeter Thermo Scientific Orion AQUAfast AQ3700 Colorimeter Featuring tests for nitrogen, phosphate and COD NEW Reagents for AQ3700 New Test Range, mg/l Reagent Type AC3002AD Acid demand ph 4.3 0.1 to 4 Tablet

More information

NEW. Multiparameter Photometers. with Advanced Optics and ph Meter

NEW. Multiparameter Photometers. with Advanced Optics and ph Meter NEW Multiparameter Photometers with Advanced Optics and ph Meter Multiparameter Photometers The HI83300 family of multiparameter photometers features nine models to cover a wide variety of applications.

More information

Portable photometer for field and laboratory use

Portable photometer for field and laboratory use Portable photometer for field and laboratory use MACHEREY-NAGEL www.mn-net.com MN Application with VISOCOLOR reagents The photometer PF-11 offers an easy start into photometric water analysis. When evaluated

More information

Photometry. Reagents

Photometry. Reagents Wave lengths λ / nm Test Range Method Cuvette AL100 AL250 AL250+ AL400 AL450 AL800 Acid capacity KS4.3 0.1-4 mmol/l - - 605 610 610 615 Acid/Indicator 1, 2 24 mm ø Alkalinity-m (total) 5-200 mg/l 610-605

More information

Why Hach Reagents? Alphabetical Listing of Reagents

Why Hach Reagents? Alphabetical Listing of Reagents Why Hach Reagents? Hach Chemical Reagents Formulated to minimize interferences, test complexity and analysis time Confirmed test performance by chemists who understand your application Designed for Maximum

More information

Photometer-System P 620. Instruction manual

Photometer-System P 620. Instruction manual Photometer-System P 620 GB Instruction manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into

More information

Instruction Manual GB

Instruction Manual GB Instruction Manual GB Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the hands of children.

More information

Instruction Manual GB

Instruction Manual GB Instruction Manual GB Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the hands of children.

More information

INSTRUCTION MANUAL. ba76126e01 03/2013. photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y

INSTRUCTION MANUAL. ba76126e01 03/2013. photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y INSTRUCTION MANUAL photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y photoflex Series For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725

More information

HI801 iris Spectrophotometer

HI801 iris Spectrophotometer HI801 Spectrophotometer with advanced split beam optical system, customizable methods and rechargeable battery iris portable spectrophotometer is unlike any of the products we have created in the past.

More information

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Reliable water analysis Precise & Affordable A complete product line of Spectrophotometers, Colorimeters and Turbidity

More information

IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING

IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING Micro 0 Revision 0// 8700-K Standard Kit 8700-WD Well Driller Kit 8700-KP Pool Kit Dual Wavelength Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Pool & Spa Water Treatment and Analysis The handbook includes detailed information

More information

GeneralCatalogue. GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents. Edition: April 2018

GeneralCatalogue. GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents. Edition: April 2018 Edition: April 2018 GeneralCatalogue GeneralCatalogue WaterAnalysis EnvironmentalAnalysis TestEquipment Reagents AQUALYTIC is a leading manufacturer of equipment for water and wastewater analysis, specializing

More information

DR /2400 and DREL /2400 Spectrophotometer + Portable Laboratories. Get moving with the DR/ 2400 spectrophotometer: Made-to-measure in situ analysis

DR /2400 and DREL /2400 Spectrophotometer + Portable Laboratories. Get moving with the DR/ 2400 spectrophotometer: Made-to-measure in situ analysis DR /2400 and DREL /2400 Spectrophotometer + Portable Laboratories Get moving with the DR/ 2400 spectrophotometer: Made-to-measure in situ analysis DR /2400 Spectrophotometer All systems go! DR/2400 Contemporary

More information

Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS AND SPAS, ENVIRONMENTAL, & EDUCATIONAL TESTING

Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS AND SPAS, ENVIRONMENTAL, & EDUCATIONAL TESTING Micro 7+ Advanced Photometer System Revision 05/6/3 48669-K Standard Kit IDEAL FOR DRINKING WATER, POOLS AND SPAS, ENVIRONMENTAL, & EDUCATIONAL TESTING USEPA, DIN, & ISO Compliant for Free & Total Chlorine

More information

Spectrophotometer AL800/SpectroDirect

Spectrophotometer AL800/SpectroDirect Spectrophotometer AL800/SpectroDirect GB Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10129 ORGANIC CARBON, TOTAL, Low Range (0.0 20.0 mg/l C) Direct Method * For water, drinking water, and wastewater HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103-105 C. Note: See DRB 200

More information

AUTOMATED WATER ANALYSIS

AUTOMATED WATER ANALYSIS APPLICATION NOTE - CFA AUTOMATED WATER ANALYSIS APPLICATIONS OF CONTINUOUS-FLOW ANALYZERS In laboratories around the world, the SEAL Analytical analyzers measure all types of water - quickly, accurately

More information

HACH CHEMISTRIES, REAGENTS AND STANDARDS

HACH CHEMISTRIES, REAGENTS AND STANDARDS HACH CHEMISTRIES, REAGENTS AND STANDARDS Hach has more than 60 years of history dedicated to formulating and packaging highquality reagents for water analysis. We understand your applications and formulate

More information

9100 UV-Vis Spectrophotometer

9100 UV-Vis Spectrophotometer 9100 UV-Vis Spectrophotometer Palintest 9100 UV-Vis Spectrophotometer UV-Vis spectroscopy from Palintest Ltd utilises the full range of formulated applications for drinking water, wastewater and industrial

More information

Checker. Handheld Colorimeters

Checker. Handheld Colorimeters Checker Handheld Colorimeters Features Easier to use and more accurate than chemical test kits High accuracy Large, easy to read digits Auto shut off Eliminates subjectivity Dedicated to a single parameter

More information

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric) METHOD #: 370.1 TITLE: Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric) ANALYTE: Silica, SiO 2 INSTRUMENTATION: Spectrophotometer STORET No. Dissolved 00955 1.0 Scope and Application

More information

Thermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter. User Guide

Thermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter. User Guide Thermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter User Guide ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. U.S. patent 6,793,787. AQUAfast, Cahn, ionplus, KNIpHE,

More information

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

TURBIDITY TB 300 IR TB 210 IR TB 250 WL.  General Catalogue April 2015 TURBIDITY 128 TB 300 IR TB 210 IR TB 250 WL www.lovibond.com General Catalogue April 2015 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid or solid

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10173 ORGANIC CARBON, TOTAL, Mid Range (15 150 mg/l C) Direct Method * For wastewater and industrial waters HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103 105 C. Note: See DRB 200 user

More information

CATALOG. Your Source for Water & Wastewater Testing Instruments

CATALOG. Your Source for Water & Wastewater Testing Instruments 2004 CATALOG Your Source for Water & Wastewater Testing Instruments The Analyst T Microprocessor Controlled for Direct-reading in mg/l, Absorbance & %Transm Model 75 MP Portable Water Analysis System Choose

More information

Nitrogen, Simplified TKN (s-tkn ) DOC

Nitrogen, Simplified TKN (s-tkn ) DOC Nitrogen, Simplified Total Kjeldahl, TNTplus 880, 10242 DOC316.53.01258 s-tkn Method Method 10242 0 to 16 mg/l TKN TNTplus 880 Scope and Application: For water and wastewater. Digestion is required. Test

More information

with IP67 BOOTH #2832

with IP67 BOOTH #2832 with IP67 4 BOOTH #2832 The new exact idip by Industrial Test Systems, Inc. (ITS is the first product in the recreational water testing market to provide complete wireless connectivity between the iphone,

More information

HANNA LITERATURE. Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry

HANNA LITERATURE. Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry HANNA LITERATURE Hanna publishes a wide range of catalogs and handbooks for an equally wide range of applications. The reference literature currently covers areas such as: Water Treatment Process Swimming

More information

Advancements in Field Testing Equipment

Advancements in Field Testing Equipment Advancements in Field Testing Equipment What will we be covering? Why do we field sample? What do we use to field sample? Why Do We Sample? Regulations or Permits Am I in compliance? Process control Is

More information

MULTIPARAMETER ION SPECIFIC METERS

MULTIPARAMETER ION SPECIFIC METERS Instruction Manual MULTIPARAMETER ION SPECIFIC METERS Manufacturers since 1978 These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna product. Please read

More information

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis Reagents Development For more than thirty years, AQUALYTIC has been manufacturing reagents for water testing and marketing these reagents around the world. Different forms of reagents are required for

More information

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at:

Online. Field Laboratory. Water Testing Product Sampler HFscientific.com. Visit our Web Site HFscientific.com. Visit Us at: Visit our Web Site HFscientific.com Water Quality Measurement Solutions Online Water Testing Product Sampler 2016 Field Laboratory 3170 Old Metro Parkway Ft. Myers, FL 33916 www.hfscientific.com toll free:

More information

Test sticks and test papers for semi-quantitative determinations

Test sticks and test papers for semi-quantitative determinations QUANTOFIX test sticks for semi-quantitative determinations QUANTOFIX test sticks meet the most important requirements for a modern quick-test: rapid dip and read convenient the analysis can be carried

More information

Advanced Photometer System

Advanced Photometer System Revision 06/07/2 Standard Kit Starter Kit Advanced Photometer System IDEAL FOR TESTING POOLS AND SPAS. ACCEPTED BY MOST HEALTH DEPARTMENTS FOR COMMERCIAL POOL AND SPA TESTING. USEPA, DIN, & ISO Compliant

More information

Checker HC. Handheld Colorimeters

Checker HC. Handheld Colorimeters Checker HC Hanna Checker HC Series The Hanna Checker HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10

More information

Reagents. Development. Tablet reagents. specifications and Certificate of analysis. Tube tests

Reagents. Development. Tablet reagents. specifications and Certificate of analysis. Tube tests Development For more than thirty years, Tintometer in Dortmund has been manufacturing reagents for water testing and marketing these reagents around the world under the brand name Lovibond. Different forms

More information

BOD Measurement. Cabinets. Photometer. Page 60 I Incubators. Page 56 I AL606. Page 6 I AL100. Page 10 I AL250. Page 56 I AL612

BOD Measurement. Cabinets. Photometer. Page 60 I Incubators. Page 56 I AL606. Page 6 I AL100. Page 10 I AL250. Page 56 I AL612 Content Photometer BOD Measurement Cabinets Page 6 I AL100 Page 56 I AL606 Page 60 I Incubators Page 10 I AL250 Page 56 I AL612 Page 62 I Spark-free cabinets Page 16 I AL250COD VARIO Page 18 I AL400 Page

More information

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis Reagents Development For more than thirty years, AQUALYTIC has been manufacturing reagents for water testing and marketing these reagents around the world. Different forms of reagents are required for

More information

IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING

IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING Revision 06/03/13 486696-PLUSK Kit Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS, SPAS, ENVIRONMENTAL, FOOD & BEVERAGE WATER QUALITY TESTING Use in accordance with U.S. Patent #7,333,194 &

More information

COD: CHEMICAL OXYGEN DEMAND

COD: CHEMICAL OXYGEN DEMAND S E C T I O N 2 C O N T E N T S N A V I G A T I O N Introduction...................... 2.2 Bench Meters..................... 2.4 Certified Reagents.............. 2.12 Thermo-Reactor................. 2.13

More information

QUALITY ASSESSMENT of WATER and WASTEWATER

QUALITY ASSESSMENT of WATER and WASTEWATER QUALITY ASSESSMENT of WATER and WASTEWATER Mamta Tomar LEWIS PUBLISHERS Boca Raton London New York Washington, D.C. Contents Chapter 1 Introduction 1 Chapter 2 Safety in the Laboratory 5 2.1 Basic Rules

More information

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter

HI EPA Compliant Turbidity Meter HI EPA Compliant Turbidity and Chlorine Meter HI 98703 EPA Compliant Turbidity Meter HI 93414 EPA Compliant Turbidity and Chlorine Meter SPECIFICATIONS Turbidity (HI 93414 & HI 98703) Range Range Selection ACCESSORIES HI 710005 Voltage adapter HI

More information

EPA Compliant Turbidity & Chlorine Meter

EPA Compliant Turbidity & Chlorine Meter EPA Compliant Turbidity & Chlorine Meter New Turbidity Technology from HANNA HANNA s new HI 98703 and HI 93414 utilize an EPA compliant tungsten light source and state-of-the-art optical system that allow

More information

Water Analysiss. Solutions for photometry

Water Analysiss. Solutions for photometry Water Analysiss Reag gents OR Reag NANOCOLOR OR Solutions for photometry Bar coded tube tests with pre-dosed reagents For highest accuracy and sensitivity in water analysis NANOCONTROL for analytical quality

More information

Reagents. Specifications and Certificate of Analysis. Green chemistry. Tablet reagents. Tube tests

Reagents. Specifications and Certificate of Analysis. Green chemistry. Tablet reagents. Tube tests Reagents Green chemistry For decades, the Tintometer Group has been known as a producer of reagents for water analysis, which are supplied under the brand name Lovibond. The wide range of applications

More information

Tintometer -Group. Reagents. Development. DPD reagents. Tablet reagents. Specifications and Certificate of Analysis

Tintometer -Group. Reagents. Development. DPD reagents. Tablet reagents. Specifications and Certificate of Analysis Tintometer -Group Reagents Development For more than thirty years, Tintometer in Dortmund has been manufacturing reagents for water testing and marketing these reagents around the world under the brand

More information

MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive

More information

Chemical Oxygen Demand

Chemical Oxygen Demand HI83314 Multiparameter Photometer with COD for Wastewater with Digital ph Electrode Input HI83314 photometer measures 10 different key wastewater quality parameters using 20 different methods that allow

More information

SOIL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SWIMMING POOL TEST KIT

SOIL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SWIMMING POOL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SOIL TEST KIT SWIMMING POOL TEST KIT 01 Analyzing Waters Anytime... Anywhere... AQUASOL test kits are extremely simple and easy to use & make monitoring convenient

More information

Phosphorus, Reactive (Orthophosphate)

Phosphorus, Reactive (Orthophosphate) Phosphorus, Reactive (Orthophosphate) DOC316.53.01118 USEPA 1, 2 PhosVer 3 Method 3 Method 8048 0.06 to 5.00 mg/l PO 4 (0.02 to 1.60 mg/l P) Test N Tube Vials Scope and application: For drinking water,

More information

DR/800 Series Colorimeters Multi-parameter analysis in the palm of your hand!

DR/800 Series Colorimeters Multi-parameter analysis in the palm of your hand! DATA SHEET DR/800 Series Colorimeters Multi-parameter analysis in the palm of your hand! Features and Benefits Choose from Three Models Depending on your testing needs, you can select a DR/820, DR/850

More information

Photometer PC 22. Operating Instructions

Photometer PC 22. Operating Instructions Photometer PC 22 GB Operating Instructions Front View Lid Stopper Cell Cell compartment LCD-Display Keypad Back View 9-pole D sub-coaxil connector Charging socket for mains supply Battery compartment with

More information

GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents

GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents GeneralCatalogue WaterAnalysis EnvironmentalAnalysis TestEquipment Reagents AQUALYTIC is a leading manufacturer of equipment for water and wastewater analysis, specializing in BOD measurement and photometry.

More information

COLORIMETERS HACH POCKET COLORIMETER II. Fluoride 0.1 to 2.0 mg/l H

COLORIMETERS HACH POCKET COLORIMETER II. Fluoride 0.1 to 2.0 mg/l H COLORIMETERS PLEASE NOTE: We offer Hach products as a convenience to our customers. We do not make recommendations for, or troubleshoot problems with Hach products. We do not make any recommendations as

More information

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D

More information

ALKALINITY (ALKAPHOT)

ALKALINITY (ALKAPHOT) PHOT.2.AUTO TEST INSTRUCTIONS ALKALINITY (ALKAPHOT) TEST FOR TOTAL ALKALINITY IN NATURAL AND TREATED WATERS Photometer Method AUTOMATIC WAVELENGTH SELECTION 0 500 mg/l CaCO 3 Natural and treated waters

More information

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive

More information

C 99 & C 200 Series Multiparameter Bench Photometers

C 99 & C 200 Series Multiparameter Bench Photometers Instruction Manual C 99 & C 200 Series Multiparameter Bench Photometers Manufacturers since 1978 These Instruments are in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna

More information

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Method (0.1 to 8.0 mg/l Cu) TNTplus 860 Chlorine, Total, Bulk Powder, 8167 DOC316.53.01255 Bathocuproine Method 1 Method 10238 (0.1 to 8.0 mg/l Cu) TNTplus 860 Scope and Application: For water, wastewater and process water. Digestion may be

More information

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2009. Edition: 11/07

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2009. Edition: 11/07 Pool & Spa Water Analysis Instruments and Reagents Edition: 03/2009 Edition: 11/07 Pool- & Spa Water Testing Instruments and Reagents for reliable Water Analysis There are very few companies which can

More information

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part

More information

Instruments & Testing Equipment

Instruments & Testing Equipment Product Index Page Pro Products Sales Demonstration Kits, Field Analysis Kits 349 Hach Test Kits 349 Hach Replacement Reagents 350 Water Test Strips, Soft Water Test 350 PurTest Test Kits 351 Lamotte Water

More information

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand Environment, Central Mine Planning and Design Institute Last Amended on - Page 1 of 9 1. POLLUTION & EFFLUENTS 1. Effluent / Waste Water Ammonical Nitrogen Free Ammonia IS 3025 (Part 34):1988, Nessler

More information

Be sensitive. Spectroquant test kits Assured quality. New sulfate, silicate and chloride test kits

Be sensitive. Spectroquant test kits Assured quality. New sulfate, silicate and chloride test kits Spectroquant test kits Assured quality For swift, secure analysis, there s no better choice than Spectroquant test kits. Consisting of validated, standard-compliant reagents, the kits are pre-programmed

More information

2013 Sanitation Testing Products

2013 Sanitation Testing Products 2013 Sanitation Testing Products Water Testing Leader Since 1919! LaMotte Test Methods Colorimetric There are two basic types of colorimetric tests: 1. Tests which determine the concentration of a substance

More information

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL COMPACT METER RANGE POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive

More information

DR 6000 UV-VIS SPECTROPHOTOMETER

DR 6000 UV-VIS SPECTROPHOTOMETER DR 6000 UV-VIS SPECTROPHOTOMETER Applications Beverage Drinking Water Industrial Water Pharmaceutical Power Wastewater The industry s most advanced lab spectrophotometer. With UV and Visible Spectrum capabilities,

More information

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835 LR, 10206 DOC316.53.01070 Dimethylphenol Method Method 10206 LR (0.23 to 13.50 mg/l NO 3 N or 1.00 to 60.00 mg/l NO 3 ) TNTplus 835 Scope and Application: For wastewater, drinking water, surface water

More information

T100 T100+ Testing items: Portable spectrophotometer. COD Cr. (low concentration) (high concentration) Ammonia Chromium VI Cyanide COD

T100 T100+ Testing items: Portable spectrophotometer. COD Cr. (low concentration) (high concentration) Ammonia Chromium VI Cyanide COD Testing items: COD Cr (low concentration) COD Cr (high concentration) Ammonia Chromium VI Cyanide COD Fluoride Nitrite Nitrate Inorganic phosphorus Manganese Nitrogen The following analyses can also be

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Silicate HR VARIO PP 1-100 mg/l SiO 2 Silicomolybdate 352 SiHr Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range

More information

Complete Water Analysis for POWER GENERATION

Complete Water Analysis for POWER GENERATION Complete Water Analysis for POWER GENERATION HACH: THE WATER ANALYSIS EXPERTS FOR POWER GENERATION Hach offers the most comprehensive water analysis solution for continuous power generation. With more

More information

HACH LCK CUVETTE TEST SYSTEM

HACH LCK CUVETTE TEST SYSTEM HACH LCK CUVETTE TEST SYSTEM Hach offers a perfectly coordinated system of photometers and reagents, required accessories and services. For all key parameters from Ammonium to Zirconium. Systematic quality

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Chlorine T a) 0.01-6.0 mg/l Cl 2 DPD 100 CL6 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Copper 50 T mg/l Cu a) Biquinoline

Copper 50 T mg/l Cu a) Biquinoline Copper 50 T 0.05-1 mg/l Cu a) Biquinoline 149 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium. , 8017 Dithizone Method 1 DOC316.53.01012 Method 8017 (0.7 to 80.0 µg/l) Powder Pillows Scope and Application: For water and wastewater; digestion is required to determine total cadmium. 1 Adapted from

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Swimming and Spa Pool Water Treatment The handbook includes detailed information

More information

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS Paper Presented by: Shane Jordan-Hill Author: Shane Jordan-Hill, Business Manager Environmental Analysis, Merck Millipore 6 th Annual

More information

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting. Sulfate DOC316.53.01473 USEPA 1 SulfaVer 4 Method 2 Method 8051 2 to 70 mg/l SO 4 2 Powder Pillows Scope and application: For water, wastewater and seawater. 1 USEPA accepted for reporting wastewater analyses.

More information

Complete Water Analysis for POWER GENERATION

Complete Water Analysis for POWER GENERATION Complete Water Analysis for POWER GENERATION HACH: THE WATER ANALYSIS EXPERTS FOR POWER GENERATION Hach offers the most comprehensive water analysis solution for continuous power generation. With more

More information