HACH CHEMISTRIES, REAGENTS AND STANDARDS
|
|
- Alban Sullivan
- 6 years ago
- Views:
Transcription
1 HACH CHEMISTRIES, REAGENTS AND STANDARDS Hach has more than 60 years of history dedicated to formulating and packaging highquality reagents for water analysis. We understand your applications and formulate our reagents to ensure exceptional performance and deliver results you can trust, time after time. Our expertise extends beyond chemistry formulation to the complete reagent system. Hach chemistries are rigorously tested in combination with our packaging and instruments to ensure the highest possible system performance. No other company can offer these advantages.
2 2 REFERENCE GUIDE Powder Pillows Powder Pillows lowprice methods with long shelf life Powder Pillows are available for a large of parameters and measuring ranges. Hermetically sealed in aluminium foil pillows, the Permachem reagents have a shelf life of many years. The reagent is simply poured into the measuring cuvette together with the sample. The evaluation can be carried out visually, e.g. with a colour disk, or with a Hach photometer. Parameter Measuring range Method Method PC II DR900 DR1900 DR3900 DR6000 GHS Aluminium mg/l Al Aluminon n n n n n Aluminium mg/l Al Eriochrome Cyanine R n n n GHS02,, Ammonia mg/l NH 3 N Salicylate n n n n n Ammonium compounds, quaternary mg/l as CTAB Direct Binary Complex n n n Barium mg/l Ba Turbidimetric n n n Benzotriazole, Tolyltriazole Tolyltriazole mg/l Benzotriazole UV Photolysis n n n n Boron mg/l B Carmine n n n Chloramine, mono mg/l Cl 2 Indophenol n n n n n Chlorine, free mg/l Cl 2 DPD , 100 n n n n n Chlorine, free mg/l Cl 2 DPD n n n n n Chlorine, free, Chlorine dioxide mg/l Cl 2 DPD , Chlorine, total mg/l Cl 2 DPD , Chlorine, total, Bromine, Iodine Cl 2 DPD , 1000 n n n n 1000 n n n n 100 n n n n n Chlorine dioxide mg/l ClO 2 DPD/Glycine n n n n n Chromium mg/l Cr (VI) 1,5Diphenylcarbohydrazide Chromium, total mg/l Cr Alkaline Hypobromite Oxidation Cobalt, Nickel mg/l Co PAN , n n n n n, n n n n, 100 n n n n,, Copper mg/l Cu Bicinchoninate n n n n n Copper µg/l Cu Porphyrin n n n n GHS02, Cyanide mg/l CN Pyridine Pyrazalone n n n n Cyanuric acid 5 50 mg/l Turbidimetric n n n Iron mg/l Fe FerroMo n n n n, PC II: Single Parameter Colorimeter, DR900: MultiParameter Colorimeter, DR1900: Portable VIS Spectrophotometer, DR3900: Benchtop VIS Spectrophotometer, DR6000: Benchtop UVVIS Spectrophotometer : product is not subject to classification Hazard descriptions: see page 9
3 REFERENCE GUIDE 3 Powder Pillows Parameter Measuring range Method Method PC II DR900 DR1900 DR3900 DR6000 GHS Iron mg/l Fe FerroVer n n n n n, Iron mg/l Fe TPTZ n n n n n, Iron mg/l Fe FerroZine n n n n Iron, ferrous mg/l Fe (II) 1,10 Phenanthroline Manganese mg/l Mn Periodate Oxidation Molybdenum mg/l Mo Mercaptoacetic Acid Molybdenum, Molybdate n n n n, n n n n n GHS02, n n n n, mg/l Mo Ternary Complex n n n n n Nickel mg/l Ni Heptoxime n n n, Nitrate mg/l NO 3 N Cadmium Reduction Nitrate mg/l NO 3 N Cadmium Reduction 8039 HR n n n n n,, n n n n,, Nitrite mg/l NO 2 N Diazotisation n n n n Nitrite mg/l NO 2 Ferrous Sulphate n n n n Oxygen scavengers µg/l Carbohydrazide Iron Reduction n n n n Phenols mg/l Phenol 4Aminoantipyrine n n n, Phosphate, Phosphate, Phosphate, mg/l PO 4 Ascorbic Acid n n n n n mg/l PO 4 Ascorbic Acid n n n n n mg/l PO 4 Ascorbic Acid n n n n Phosphonates mg/l PO 4 Persulfate UV Oxidation n n n n n GHS03,, Potassium mg/l K Tetraphenylborate n n n, Silica mg/l SiO 2 Silicomolybdate n n n n n Silica mg/l SiO 2 Heteropoly Blue n n n n, Silver mg/l Ag Colorimetric n n n, Sulphate 2 70 mg/l SO 4 SulfaVer 4, turbidimetric Total Kjeldahl Nitrogen (TKN) n n n n n mg/l TKN Nessler n n n n GHS02,, Zinc mg/l Zn Zincon n n n n n GHS02,,,
4 4 REFERENCE GUIDE Swiftests The right amout of DPD with the Swiftest The Swiftest is a powder dispenser that releases the correct amount of DPD (N,Ndiethylpphenylenediamine) at the press of a button. It contains enough reagent for 250 chlorine tests (free or total chlorine). As a practical, attractively priced alternative, the Swiftest is ideal for laboratories with a high sample throughput, and for analysis in the field. Product description Measuring range Method Method Swiftest DPD Free chlorine reagent dispenser and reagent vial DPD Total chlorine, Swiftest dispenser reagent (refill) DPD Free chlorine, Swiftest dispenser reagent (refill) Swiftest DPD Total chlorine reagent dispenser and reagent vial mg/l Cl 2 DPD , mg/l Cl 2 DPD , mg/l Cl 2 DPD , mg/l Cl 2 DPD , PC II DR900 DR1900 DR3900 DR6000 GHS 250 n n n n n 250 n n n n n, 250 n n n n n 250 n n n n n, PC II: Single Parameter Colorimeter, DR900: MultiParameter Colorimeter, DR1900: Portable VIS Spectrophotometer, DR3900: Benchtop VIS Spectrophotometer, DR6000: Benchtop UVVIS Spectrophotometer : product is not subject to classification Hazard descriptions: see page 9
5 REFERENCE GUIDE 5 Accuvacs Accuvac analysing without pipetting The secret of the Accuvac is the vacuum in the sealed glass cuvette containing a measured amount of reagent. The test is carried out by immersing the tip of the Accuvac in the sample, then breaking it by applying moderate pressure. The vacuum draws the sample into the cuvette, whilst ensuring thorough mixing. The resulting colour is measured visually or photometrically Chlorine, free, Chlorine dioxide Parameter Measuring range Method Method Chlorine, total Bromine Iodine mg/l Cl mg/l Br mg/l I Chromium mg/l Cr (VI) mg/l Cl 2 DPD , DPD 8167 Chlorine 1,5Diphenylcarbohydrazide PC II DR900 DR1900 DR3900 DR6000 GHS 25 n n n n n 25 n n n n n n n n n n Copper mg/l Cu Bicinchoninate n n n n n Fluoride mg/l F SPADNS n n n n n Iron mg/l Fe FerroVer n n n n n, Iron mg/l Fe Iron mg/l Fe (II) Nitrate mg/l NO 3 N Nitrite mg/l NO 2 N Oxygen, dissolved Oxygen, dissolved TPTZ n n n n n, 1,10 Phenanthroline n n n n, Cadmium Reduction n n n n n, Diazotisation n n n n µg/l O 2 Indigo Carmine n n n n mg/l O 2 HRDO n n n n n,, Ozone mg/l O 3 Indigo n n n n n Ozone mg/l O 3 Indigo n n n n n Ozone mg/l O 3 Indigo n n n n Phosphate, Phosphate, mg/l PO 4 Ascorbic Acid n n n n n mg/l PO 4 Molybdovanadate n n n n GHS Sulphate 2 70 mg/l SO 4 SulfaVer n n n n n PC II: Single Parameter Colorimeter, DR900: MultiParameter Colorimeter, DR1900: Portable VIS Spectrophotometer, DR3900: Benchtop VIS Spectrophotometer, DR6000: Benchtop UVVIS Spectrophotometer : product is not subject to classification Hazard descriptions: see page 9
6 6 REFERENCE GUIDE Liquid Reagent Tests Reagent solutions, economic liquid reagent tests and rapid liquid systems Reagent tests for the determination of numerous parameters required in drinking, waste and process water applications as well as product and monitoring. A costeffective solution for your highvolume testing and serial analysis. Parameter Measuring range Ammonia mg/l NH 3 N Cadmium µg/l Cd Method Method Chlorine, free DPD , mg/l Cl 2 HPT210 Chlorine, free mg/l HPT310 Chlorine, free + total PC II DR900 DR1900 DR3900 DR6000 GHS Nessler Dithizone ,, DPD, DPD RS, mg/l Cl Chlorine, total DPD 8370, mg/l Cl LCW510 Chlorine/Ozone mg/l Cl 2 / O 3 (round cuvette) GHS GHS DPD Chlorine dioxide Chlorophenol Red mg/l ClO 2 HPT240 Chlorine dioxide Amaranth Method 100 mg/l ClO Cobalt, Nickel mg/l Co Fluoride mg/l F Formaldehyde µg/l CH 2 O PAN , ,, SPADNS MBTH Hardness µg/l Chlorophosphonazo CaCO Hardness, Ca and Mg mg/l Ca as CaCO Hydrazine µg/l N 2 H 4 LCW025 Hydrazine mg/l N 2 H 4 LCW058 Hydrogen peroxide Iron mg/l Fe Calmagite Colorimetric pdimethylaminobenzaldehyde 4Dimethylaminobenzaldehyde GHS05 60 GHS g/l H 2 O 2 Peroxomolybdate 40 GHS05 FerroZine PC II: Single Parameter Colorimeter, DR900: MultiParameter Colorimeter, DR1900: Portable VIS Spectrophotometer, DR3900: Benchtop VIS Spectrophotometer, DR6000: Benchtop UVVIS Spectrophotometer : product is not subject to classification Hazard descriptions: see page 9
7 REFERENCE GUIDE 7 Liquid Reagent Tests Parameter Measuring range LCW021 Iron mg/l Fe Lead µg/l Pb Manganese mg/l Mn LCW532 Manganese mg/l Mn LCW032 Manganese mg/l Mn (round cuvette or 10 mm rectangular cuvette) Mercury µg/l Hg Method Iron(II) ions react with FerroZine to form a violet complex compound Method PC II DR900 DR1900 DR3900 DR6000 GHS 50 GHS05 LeadTrak , PAN , 1(2pyridylazo)2 naphthol (PAN) 50 GHS02,, Formaldoxime LCA706 50,, Cold Vapour Concentration GHS03,,, ph ph Colorimetric Phenol Red Phosphate, Phosphate, Phosphate, LCW250 Reducing agent mg/l DEHA Molybdovanadate mg/l PO Amino Acid mg/l PO Molybdovanadate mg/l PO 4 Iron Reduction Method Silica µg/l Heteropoly Blue SiO Silica µg/l Heteropoly Blue SiO Silica µg/l Heteropoly Blue SiO 2, LCW028 Silica Molybdenum Blue 50 mg/l SiO Sulphide µg/l Methylene Blue S 2 LCW053 Sulphide mg/l S 2 Dimethylpphenylenediamine HPT430 Sulphite mg/l Hach Method SO 3 LCW054 Sulphite mg/l Hach Method SO Tannin & Lignin mg/l as Tannic Acid Tyrosine , Trihalomethanes µg/l THM Plus CHCl Volatile acids mg/l HOAc Esterification ,
8 8 REFERENCE GUIDE Test N Tubes Test N Tubes Safe and convenient testing Test N Tube cuvette tests are completely equipped with all premeasured reagents, optimised for reliable measuring results and easy handling. Capped 16 mm vials provide a selfcontained package for mixing and measurement. All necessary reagents and vials are contained in the package. Parameter Measuring range Method Method Ammonia mg/l NH 3 N Salicylate , Ammonia mg/l NH 3 N Salicylate , Chlorine mg/l Cl 2 DPD , COD mg/l O 2 Dichromate , , COD mg/l O 2 Dichromate , , COD mg/l O 2 Dichromate without mercury (not approved for USEPA reporting purposes) COD mg/l O 2 Dichromate without mercury (not approved for USEPA reporting purposes) , , , , COD mg/l O 2 Dichromate , , COD mg/l O 2 Manganese (III) , , DR900 GHS n n GHS05 50 n 25 n, 25 n, 25 n 25 n, 25 n, 25 n GHS Nitrate mg/l NO 3 N Chromotropic Acid n Nitrite mg/l NO 2 N Diazotization n Nitrogen, total mg/l N Persulphate Digestion , 15349, n GHS03,, DR900: MultiParameter Colorimeter Please note: Some methods require reagent blanks. For these, the varies. : product is not subject to classification Hazard descriptions: see page 9
9 REFERENCE GUIDE 9 Test N Tubes Parameter Measuring range Method Method Nitrogen, total mg/l N Persulphate Digestion , DR900 GHS n GHS03,, Phosphate, mg/l PO 4 Ascorbic Acid n Phosphate, + total mg/l PO 4 Ascorbic Acid n GHS03,, Phosphate, mg/l PO 4 Molybdovanadate n GHS Phosphate, total mg/l PO 4 PhosVer 3 with Acid Persulfate Digestion Phosphate, total mg/l PO 4 Molybdovanadate with Acid Persulfate Digestion n GHS03,, n GHS03,, TOC mg/l C Direct n GHS03,, TOC mg/l C Direct n GHS03,, TOC mg/l C Direct n GHS03,, GHS s GHS01 GHS02 GHS03 GHS04 GHS05 GHS06
10 10 REFERENCE GUIDE Standard Solutions Single parameter for Analytical Assurance Regular use of standard solutions can ensure laboratory process, increase your confidence, and help provide evidence of performance to inspectors, regulators, and clients. Single parameters are available in a variety of analytes and concentrations for proof of accuracy. Parameter Product description Concentration GHS Alkalinity Sulphuric acid standard solution, N, 100 ml MDB N GHS05 Alkalinity Sulphuric acid standard solution, N, 1 L N GHS05 Ammonia Ammonia standard solution, 10 mg/l NH 3 N, 500 ml 10 mg/l NH₃N Ammonia Ammonia standard solution, 1mg/L NH 3 N, 500 ml 1 mg/l NH₃N Ammonia Ammonia standard solution, 100 mg/l NH 3 N, 500 ml 100 mg/l NH 3 N AOX LCA390 Addista Mono standard for AOX cuvette test LCK390 Lot specific concentration BOD LCA555 Addista Mono standard for BOD cuvette test LCK mg/l O 2 GHS03, BOD BOD standard solution, 300 mg/l O 2, 10 ml, 16 pcs. 300 mg/l O 2 BOD BOD standard solution, 3000 mg/l O 2, 10 ml, 16 pcs mg/l O 2 Chlorine LCA310 Addista Mono standard for chlorine cuvette test LCK mg/l Cl 2 Chlorine Chlorine standard solution, 5075 mg/l Cl 2 (NIST) mg/l Cl 2 Chlorine Chlorine standard solution, 2530 mg/l Cl 2 (NIST), 20 pcs mg/l Cl 2 GHS05 Chlorine SpecCheck Gel secondary standard Kit, LR chlorine, DPD, 02.0 mg/l Cl mg/l Cl 2 COD COD standard solution, 300 mg/l O 2 (NIST), 200 ml 300 mg/l O 2 COD COD standard solution, 1000 mg/l O 2 (NIST), 200 ml 1000 mg/l O 2 COD COD standard solution, 300 mg/l O 2 (NIST), 500 ml 300 mg/l O 2 Colour Colour standard solution, 500 Pt Co Units, 1 L 500 Pt Co units GHS05 Colour Colour standard solution, 15 Pt Co Units, 1 L 15 Pt Co units GHS05 Conductivity Sodium chloride standard solution, 1000 µs/cm (NIST), 100 ml 1000 µs/cm Conductivity Sodium chloride standard solution, 1000 µs/cm (NIST), 500 ml 1000 µs/cm Conductivity Sodium chloride standard solution, 1990 µs/cm (NIST), 1 L 1990 µs/cm Conductivity Sodium chloride standard solution, 100 µs/cm (NIST), 500 ml 100 µs/cm Conductivity Sodium chloride standard solution, µs/cm (NIST), 500 ml µs/cm Iron Iron standard solution mg/l Fe (NIST), 100 ml 100 mg/l Fe GHS05 Nitrite Nitrite standard solution, 250 mg/l NO 2 N, APHA, 500 ml 250 mg/l NO 2 N Phosphate Phosphate standard solution, 15 mg/l PO 4, 100 ml 15 mg/l PO 4 Phosphate Phosphate standard solution, 50 mg/l PO 4 (NIST), 500 ml 50 mg/l PO 4 Phosphate Phosphate standard solution, 1 mg/l PO 4, 500 ml 1 mg/l PO 4 Silica Silica standard solution, 1 mg/l SiO 2 (NIST), 500 ml 1 mg/l SiO 2 Sulphate Sulphate standard solution, 1000 mg/l SO 4 (NIST), 500 ml 1000 mg/l SO 4 Sulphate Sulphate standard solution, 50 mg/l SO 4 (NIST), 500 ml 50 mg/l SO 4 Surfactants, nonionic LCA333 Addista Surfactants standard for LCK333 1g/L TRITON x g/l TRITON x 100 Varies Sulphuric acid standard solution, 5.25 N, 100 ml 5.25 N GHS05 Varies Sulphuric acid standard solution, N, 1 L N GHS05 Varies Sodium hydroxide standard solution, 6 N, 1 L 6.0 N GHS05 Varies Sulphuric acid 0.04 N, 500 ml 0.04 N GHS05 Varies Potassium hydroxide standard solution, 8.00 N, 500 ml 8.00 N : product is not subject to classification Hazard descriptions: see page 9
11 REFERENCE GUIDE 11 Hach Spectrophotometers and Colorimeters DR6000 UVVIS Spectrophotometer DR3900 VIS Spectrophotometer DR1900 Portable VIS Spectrophotometer DR900 MultiParameter Colorimeter Pocket Colorimeter II Single Parameter Colorimeter
12 SL1000 PORTABLE PARALLEL ANALYSER (PPA) Water quality testing. Dramatically streamlined. The new Hach SL1000 Portable Parallel Analyser (PPA) performs common water tests with less than half the manual steps. It produces highly accurate results with less opportunity for errors in a fraction of the time and allows for up to six parameters to be tested simultaneously. Less variability Avoid manual steps that can introduce variability, even when performed by experienced testers. Automation and internal temperature make the entire process consistent and repeatable, while applying the same processes and reagents as current Hach methods. Chemkey technology Chemkey reagents contain the same chemicals and execute the same process steps that you have trusted for decades now delivered in a simple, selfcontained package. EPAapproved for reporting of Free and Total Chlorine in drinking water applications. Less headache A single instrument combines colorimetric and electrochemical testing in a field kit that requires fewer bulky accessories. There are no powder pillows or glass vials to handle. All chemicals and processes are entirely contained inside the Chemkey. Faster testing Perform up to four colorimetric and two probebased measurements in parallel, and complete the entire test suite in 25% of the time. Improve efficiency by completing more tests on site with faster results. DOC Sep15
Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside!
Laboratory & Field Instruments: See Inside! Quick Reference Guide See pages 86-87. for Spectrophotometers and Colorimeters See pages 88-90. for Turbidimeters See pages 90. Pour-Thru See pages 91. Quick
More informationCatalogue. Laboratory Water Analysis Photometric and Electrochemical Instruments, Reagents and Services
Catalogue Laboratory Water Analysis Photometric and Electrochemical Instruments, Reagents and Services 2 INTRODUCTION HACH LANGE Photometric and Electrochemical Instruments, Reagents & Services With high
More informationDR/800 Series Colorimeters Multi-parameter analysis in the palm of your hand!
DATA SHEET DR/800 Series Colorimeters Multi-parameter analysis in the palm of your hand! Features and Benefits Choose from Three Models Depending on your testing needs, you can select a DR/820, DR/850
More informationHACH LCK CUVETTE TEST SYSTEM
HACH LCK CUVETTE TEST SYSTEM Hach offers a perfectly coordinated system of photometers and reagents, required accessories and services. For all key parameters from Ammonium to Zirconium. Systematic quality
More informationThermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries
Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries Please visit our website at thermofisher.com/mastermethods for the latest instructions for Thermo
More informationDR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis
DR/800 Series Colorimeters High-Value, High-Capability Instruments for Water Quality Analysis DR/800 Series Colorimeters Hach DR/800 Series Colorimeters combine ease of use, multiple testing capabilities
More informationNEW. Multiparameter Photometers. with Advanced Optics and ph Meter
NEW Multiparameter Photometers with Advanced Optics and ph Meter Multiparameter Photometers The HI83300 family of multiparameter photometers features nine models to cover a wide variety of applications.
More informationWhy Hach Reagents? Alphabetical Listing of Reagents
Why Hach Reagents? Hach Chemical Reagents Formulated to minimize interferences, test complexity and analysis time Confirmed test performance by chemists who understand your application Designed for Maximum
More informationPortable photometer for field and laboratory use
Portable photometer for field and laboratory use MACHEREY-NAGEL www.mn-net.com MN Application with VISOCOLOR reagents The photometer PF-11 offers an easy start into photometric water analysis. When evaluated
More informationAQUALYTIC. Parameter, Ranges and Reagents for. Chloride 530 Silver nitrate/turbidity mg/l Cl
AQUALYTIC Parameter, Ranges and Reagents for Test λ a) / nm Method Range Display Alkalinity-m (total) 610 Acid/Indicator 1, 2 5-200 mg/l CaCO 3 Alkalinity-p 560 Acid/Indicator 1, 2 5-500 mg/l CaCO 3 Aluminium
More informationLaboratory & Field Instruments: Spectrophotometers & Colorimeters
Laboratory & Field Instruments: Spectrophotometers & Colorimeters See Inside! DR Family of Spectrophotometers See pages 60-71. DR 3800 Benchtop Spectrophotometer See page 69. TNTplus Reagents Bar-coded
More informationHI801 iris Spectrophotometer
HI801 Spectrophotometer with advanced split beam optical system, customizable methods and rechargeable battery iris portable spectrophotometer is unlike any of the products we have created in the past.
More informationDelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers
DelAgua Safe Water Reagent Identification Chart for Lovibond Tintometer photometers For Use: Identify the parameter required, ensure the parameter matches your photometer, codes required for the test are
More informationAvailable tests for the photometer MD600 / MaxiDirect New Tests
Available tests for the photometer MD600 / MaxiDirect New s 20 Acid demand ph 4.3 T 610 Acid / Indicator 1, 2 0.1-4 mmol/l ALKA-M PHOTOMETER 513210BT 30 Alkalinity-m T (total) 610 Acid / Indicator 1, 2
More informationWater Analysiss. Solutions for photometry
Water Analysiss Reag gents OR Reag NANOCOLOR OR Solutions for photometry Bar coded tube tests with pre-dosed reagents For highest accuracy and sensitivity in water analysis NANOCONTROL for analytical quality
More informationRECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed
Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part
More informationDR 1900 PORTABLE SPECTROPHOTOMETER
DR 1900 PORTABLE SPECTROPHOTOMETER Applications Drinking Water Wastewater Field Use Industrial Water Power Carry more water methods with you wherever you need them most. The DR 1900 combines the ruggedness
More informationComparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.
Comparator 2000+ The system for colorimetric water analysis Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing
More informationChemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits
Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Page A2 A4 A6 A20 A1 Single Parameter Simple and Economical Analysis HANNA instruments test kits are the
More informationDR/2010. In the field or in the lab
DR/2010 In the field or in the lab Convenient, easy to use with factory-installed procedures, unitdose reagents, illustrated manuals and on-screen prompting software available in six different languages.
More informationTest sticks and test papers for semi-quantitative determinations
QUANTOFIX test sticks for semi-quantitative determinations QUANTOFIX test sticks meet the most important requirements for a modern quick-test: rapid dip and read convenient the analysis can be carried
More informationPhotometer-System using Dual Beam Technology
Tintometer Photometer-System using Dual Beam Technology Dual Beam Technology and Interference Filters for best accuracy 44 Applications Waste Water Drinking Water Industrial Process Water Scientific Applications
More informationThermo Scientific Orion AQUAfast AQ3700 Colorimeter
Thermo Scientific Orion AQUAfast AQ3700 Colorimeter Featuring tests for nitrogen, phosphate and COD NEW Reagents for AQ3700 New Test Range, mg/l Reagent Type AC3002AD Acid demand ph 4.3 0.1 to 4 Tablet
More informationSP600. Spectrophotometer. Instruction Manual
SP600 Spectrophotometer Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the
More informationChecker. Handheld Colorimeters
Checker Handheld Colorimeters Features Easier to use and more accurate than chemical test kits High accuracy Large, easy to read digits Auto shut off Eliminates subjectivity Dedicated to a single parameter
More informationEnvironment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra
Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D
More informationEnvironment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand
Environment, Central Mine Planning and Design Institute Last Amended on - Page 1 of 9 1. POLLUTION & EFFLUENTS 1. Effluent / Waste Water Ammonical Nitrogen Free Ammonia IS 3025 (Part 34):1988, Nessler
More informationSpectrophotometer AL800/SpectroDirect
Spectrophotometer AL800/SpectroDirect GB Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must
More informationDescription Number Price Digital Titrator Rapid, accurate results Easily monitor total chromium for process control
Chromate Description Method Platform Range # Tests Number Price DIGITAL TITRATOR TITRATION 8211 Chromate Reagent Set PP, DT 20-400 mg/l CrO 2-4 100 2272400 (1) Dissolved Oxygen 3 Powder Pillows PP 100
More informationMC500 Multi-Parameter Colorimeter
MC500 Multi-Parameter Colorimeter Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Keep reagents out
More informationPhotometry. Reagents
Wave lengths λ / nm Test Range Method Cuvette AL100 AL250 AL250+ AL400 AL450 AL800 Acid capacity KS4.3 0.1-4 mmol/l - - 605 610 610 615 Acid/Indicator 1, 2 24 mm ø Alkalinity-m (total) 5-200 mg/l 610-605
More informationDetermination Art. No. Total range Cell size [mm]
Spectroquant Prove The following methods with the corresponding method numbers are programmed into the photometer. The measurements can be made without any further adjustments. In addition several applications
More informationCOD: CHEMICAL OXYGEN DEMAND
S E C T I O N 2 C O N T E N T S N A V I G A T I O N Introduction...................... 2.2 Bench Meters..................... 2.4 Certified Reagents.............. 2.12 Thermo-Reactor................. 2.13
More informationPrecise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure
Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Reliable water analysis Precise & Affordable A complete line of Spectrophotometers, Colorimeters and Turbidity
More informationEPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)
NORTH TEXAS MUNICIPAL WATER DISTRICT - Wylie Water Analysis Jan-2018 Mineral Analysis Raw Treated Standards Residue on Evaporation 412 456 500 1000 Silica (SiO2) 3.63 3.41 Iron (Fe) 0.378 0.259 0.3 0.3
More informationDR 6000 UV-VIS SPECTROPHOTOMETER
DR 6000 UV-VIS SPECTROPHOTOMETER Applications Beverage Drinking Water Industrial Water Pharmaceutical Power Wastewater The industry s most advanced lab spectrophotometer. With UV and Visible Spectrum capabilities,
More informationHaryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date
Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide
More informationMULTIPARAMETER ION SPECIFIC METERS
Instruction Manual MULTIPARAMETER ION SPECIFIC METERS Manufacturers since 1978 These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna product. Please read
More informationSuperintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal
Last Amended on - Page 1 of 16 I. WATER 1. Drinking Water ph IS 3025 (Part 2): 2004, Colour APHA (22 nd Edition) 2120 B: Turbidity (NTU) IS 3025 (Part 10): 1984 Residual, Free Chlorine IS 3025 Part 26/1986
More informationKits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT
Kits Item Product name Article Number 1 ACIDITY TEST AQUAMERCK 1.11108.0001 2 ALCOHOL TEST 15-150 MG/L REFLECTOQUANT 1.17946.0001 3 ALKALINITY TEST AQUAMERCK 1.11109.0001 4 ALUMINIUM TEST 0.020-1.20 MG/L
More informationQUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;
REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : ENVIRONMENTAL DATA - Temperature min. : C - Temperature max. : C - Altitude (m.a.s.l) : m - Plant location (geographic area, seismic zone,
More informationHANNA LITERATURE. Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry
HANNA LITERATURE Hanna publishes a wide range of catalogs and handbooks for an equally wide range of applications. The reference literature currently covers areas such as: Water Treatment Process Swimming
More informationKKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana
Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m
More informationCOLORIMETERS HACH POCKET COLORIMETER II. Fluoride 0.1 to 2.0 mg/l H
COLORIMETERS PLEASE NOTE: We offer Hach products as a convenience to our customers. We do not make recommendations for, or troubleshoot problems with Hach products. We do not make any recommendations as
More informationReagents. Development. Tablet reagents. specifications and Certificate of analysis. Tube tests
Development For more than thirty years, Tintometer in Dortmund has been manufacturing reagents for water testing and marketing these reagents around the world under the brand name Lovibond. Different forms
More informationReagents. Development. Tablet reagents. Specifications and Certificate of Analysis
Reagents Development For more than thirty years, AQUALYTIC has been manufacturing reagents for water testing and marketing these reagents around the world. Different forms of reagents are required for
More informationReagents. Development. Tablet reagents. Specifications and Certificate of Analysis
Reagents Development For more than thirty years, AQUALYTIC has been manufacturing reagents for water testing and marketing these reagents around the world. Different forms of reagents are required for
More informationGround Water & UST Samples: Containers, Preservation and Hold Times Table
Ground Water & UST Samples: Containers, Preservation and Hold Times Table North Carolina Division of Water Resources, Water Sciences Section Chemistry Laboratory Reference: 40 CFR Part 136.3 Table II Listed
More informationMadhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh
Madhya Pradesh Waste Management Project, Certificate Number TC-5022 (in lieu of T-2449) Page 1 of 8 CHEMICAL TESTING I. POLLUTION AND ENVIRONMENT 1. Waste Water (Effluent & Sewage) ph APHA 22nd Edition,
More information9100 UV-Vis Spectrophotometer
9100 UV-Vis Spectrophotometer Palintest 9100 UV-Vis Spectrophotometer UV-Vis spectroscopy from Palintest Ltd utilises the full range of formulated applications for drinking water, wastewater and industrial
More informationCERTIFICATE OF ANALYSIS
Your C.O.C. #: 32531001 Attention: Scott Churko Engineering and Operations Dpt PO Box 1390 Parksville, BC Canada V9P 2H3 CERTIFICATE OF ANALYSIS MAXXAM JOB #: B279455 Received: 2012/09/06, 09:15 Sample
More informationSchedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent
LABORATORY LOCATION: (PERMANENT LABORATORY) Page: 1 of 12 SPECTRUM LABORATORIES (PENANG) SDN. BHD. 1904 TINGKAT 1, JALAN BUKIT MINYAK TAMAN SRI MANGGA, 14000 BUKIT MERTAJAM SEBERANG PRAI TENGAH PULAU PINANG
More informationAUTOMATED WATER ANALYSIS
APPLICATION NOTE - CFA AUTOMATED WATER ANALYSIS APPLICATIONS OF CONTINUOUS-FLOW ANALYZERS In laboratories around the world, the SEAL Analytical analyzers measure all types of water - quickly, accurately
More informationSpecification and Certificate of Analysis
Reagents Green chemistry For decades, the Tintometer Group has been known as a producer of reagents for water analysis, which are supplied under the brand name Lovibond. The wide range of applications
More information2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY
THE WATER ACT, 1956 (ACT 54 OF 1956 ) AND ITS REQUIREMENTS IN TERMS OF WATER SUPPLIES FOR DRINKING WATER AND FOR WASTE WATER TREATMENT AND DISCHARGE INTO THE ENVIRONMENT 1. INTRODUCTION The provisions
More informationBe sensitive. Spectroquant test kits Assured quality. New sulfate, silicate and chloride test kits
Spectroquant test kits Assured quality For swift, secure analysis, there s no better choice than Spectroquant test kits. Consisting of validated, standard-compliant reagents, the kits are pre-programmed
More informationLovibond Water Testing. Tintometer Group. General Catalogue. General Catalogue. Instruments and Reagents for Today s Water Analysis.
General Catalogue Lovibond Water Testing Tintometer Group General Catalogue Instruments and Reagents for Today s Water Analysis www.lovibond.com PHILOSOPHY Water is the basis of life. And it also provides
More informationLIST OF TESTING SERVICES CHEMICAL
-MATERIAL A. Soil LIST OF TESTING SERVICES 1 Water Soluble Chloride Content in Soil BS 1377 Part 3 2 Acid Soluble Chloride Content in Soil BS 1377 Part 3 3 Water Soluble Sulphate Content in Soil BS 1377
More informationReagents. Specifications and Certificate of Analysis. Green chemistry. Tablet reagents. Tube tests
Reagents Green chemistry For decades, the Tintometer Group has been known as a producer of reagents for water analysis, which are supplied under the brand name Lovibond. The wide range of applications
More informationAppendix C: Water Quality Data
Appendix C: Water Quality Data Your Project #: 111257005 Site: TIM HORTONS SYLVIA LAKE NSD # 16300R Attention: DAVID WHETTER STANTEC CONSULTING LTD 603-386 BROADWAY AVENUE WINNIPEG, MB CANADA R3C
More informationMethod (0.1 to 8.0 mg/l Cu) TNTplus 860
Chlorine, Total, Bulk Powder, 8167 DOC316.53.01255 Bathocuproine Method 1 Method 10238 (0.1 to 8.0 mg/l Cu) TNTplus 860 Scope and Application: For water, wastewater and process water. Digestion may be
More informationSurface Water Samples: Containers, Preservation and Hold Times Table
Surface Water Samples: Containers, Preservation and Hold Times Table North Carolina Division of Water Resources, Water Sciences Section Chemistry Laboratory Reference: 40 CFR Part 136.3 Table II Listed
More informationWater and Food Analytics. Test Kits, Instruments and Accessories
Water and Food Analytics Test Kits, Instruments and Accessories How can I obtain sound analytical results quickly and reliably? Quite simply: Take advantage of more than 100 years of experience in chemical
More informationMethod Analytical principle Relation to standards. Ammonium Gas diffusion/ ph-indicator DIN EN ISO (Ammonia)
FIA List of Methods Release: 24.03.2016 Total Pyrocatechol violet APHA 3500 Al modified Aluminium 0.01 mg/l 0.05... 0.5 mg/l Al-T Water / Wastewater 0.2... 2 mg/l Al-T Ammonium Gas diffusion/ ph-indicator
More informationSCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS
SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,
More informationSustainability and environmental protection. Tintometer places great importance on sustainability and the sensitive use of natural resources.
Tintometer -Group There are very few companies which can look back over a history of more than 125 years of success. The reason we can do so lies in the world-wide appreciation of our products and the
More information1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method to mg/l Mn (LR) Powder Pillows
Manganese, LR DOC316.53.01057 1-(2-Pyridylazo)-2-Naphthol PAN Method 1 Method 8149 0.006 to 0.700 mg/l Mn (LR) Powder Pillows Scope and application: For water and wastewater; digestion is necessary for
More informationALKALINITY (ALKAPHOT)
PHOT.2.AUTO TEST INSTRUCTIONS ALKALINITY (ALKAPHOT) TEST FOR TOTAL ALKALINITY IN NATURAL AND TREATED WATERS Photometer Method AUTOMATIC WAVELENGTH SELECTION 0 500 mg/l CaCO 3 Natural and treated waters
More information3. Add 0.4 ml of. 7. Use a TenSette
Method 10129 ORGANIC CARBON, TOTAL, Low Range (0.0 20.0 mg/l C) Direct Method * For water, drinking water, and wastewater HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103-105 C. Note: See DRB 200
More informationPaSEC Colorimeter Instructions DR850
PaSEC Colorimeter Instructions DR850 OXYGEN, DISSOLVED, High Range (0 15.0 mg/l O 2 ) Dissolved Oxygen Test Colorimeter Instruction #4 Replacement: Using the AccuVac Snapper Tool Breaking the Dissolved
More informationSIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015)
SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015) ARA OCP (ARA SARUBERA GROUP OF MINES) KUJU AREA CENTRAL COALFIELDS LIMITED (A Miniratna
More informationDurban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014
Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July 2013-30 June 2014 Durban Heights WW Raw Durban Heights WW Final Determinands Units Minimum Average Percentile Maximum Minimum Average
More information3. Add 0.4 ml of. 7. Use a TenSette
Method 10173 ORGANIC CARBON, TOTAL, Mid Range (15 150 mg/l C) Direct Method * For wastewater and industrial waters HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103 105 C. Note: See DRB 200 user
More informationTintometer -Group. Reagents. Development. DPD reagents. Tablet reagents. Specifications and Certificate of Analysis
Tintometer -Group Reagents Development For more than thirty years, Tintometer in Dortmund has been manufacturing reagents for water testing and marketing these reagents around the world under the brand
More informationChecker HC. Handheld Colorimeters
Checker HC Hanna Checker HC Series The Hanna Checker HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10
More informationOverview of parameters from A-Z page All test kits at a glance. Visual test kits. ph test strips and papers page 14-17
Overview of parameters from A-Z page 2-13 All test kits at a glance Visual test kits ph test strips and papers page 14-17 ph determination made easy Merckoquant page 18-25 The universal test strip for
More informationMULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL
MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive
More informationAnalysis of dissolved nitrite (NO 2- )
Analysis of dissolved nitrite (NO 2 ) Table of content 1. PURPOSE... 2 2. PRINCIPLE... 2 3. REQUIREMENTS... 3 3.1. EQUIPMENT AND MATERIALS... 3 3.2. REAGENTS... 3 4. PROCEDURE... 3 4.1. SAMPLE PREPARATION...
More informationState of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation
Matrix: CWA (Non Potable Water) Discipline: Chemistry ASTM D516-07 ASTM D6888-09 ASTM D7511-09e2 EPA 160.4 EPA 1631E EPA 1664A EPA 1664A (SGT-HEM) EPA 180.1 Sulfate 8/1/2018 Cyanide, Amenable 8/1/2018
More informationEuropean Pharmacopoeia Solutions
European Pharmacopoeia Solutions European Pharmacopoeia Solutions Reagecon, as a specialist manufacturer of laboratory reagents has now introduced the range of Reagents and Standard solutions in Chapters
More informationTITLE: SABS PROFICIENCY TESTING SCHEME, RSA
TITLE: SABS PROFICIENCY TESTING SCHEME, RSA PRESENTED BY: Ms C. MODIKA Contact Info : +7(0) 48 6383 Fax No. ; +7(0) 48 609 Email : Modikac@sabs.co.za TANZANIA, 3 8 December 007 Mission Mission Statement
More informationThermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter. User Guide
Thermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter User Guide ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. U.S. patent 6,793,787. AQUAfast, Cahn, ionplus, KNIpHE,
More informationFormula & Equation Writing
Formula & Equation Writing Book 2 H H Al Al H Al(H) 3 H Ionic Equations Ionic Formulae Balanced Equations Formula Equations Word Equations Transition Metals Using Brackets Awkward Customers More than 2
More informationCERTIFICATE OF ANALYSIS
BAY 3, 4500 5TH STREET NE CALGARY, AB CANADA T2L 7C3 MAXXAM JOB #: A814851 Received: 2008/04/02, 13:15 Matrix: Water # s Received: 1 This report supersedes all previous reports with the same Maxxam job
More informationNichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka
Last Amended on - Page 1 of 9 I. WATER 1. Drinking Water Colour 2120 B 1 to 100 Hazen Units ph 4500 H+, B 3 to 12 Electrical conductivity 2510 B 5 to 10,000 µs/cm Turbidity 2130 B 1 to 100 NTU Chloride
More informationComparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards
Comparator 2000+ Colorimeter for regular testing in public pools & spas with colour-stable glass standards 24 www.lovibond.com Pool & Spa Water Testing - January 2013 Comparator 2000+ With its accessories,
More informationState of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation
Matrix: CWA (Non Potable Water) Discipline EPA 120.1 Chemistry Conductivity 8/1/2015 Aluminum 8/1/2015 Antimony 8/1/2015 Arsenic 8/1/2015 Barium 8/1/2015 Beryllium 8/1/2015 Boron 8/1/2015 Cadmium 8/1/2015
More informationSampling and analysis
Sampling and analysis Released: 12 December 2017 As a condition of Discharge Authorisation, we may require customers to collect samples of their trade waste discharges for laboratory analysis. The results
More informationCertificate of Analysis
Town of Niverville ATTN: RYAN DYCK/ANDREW REMPEL PO Box 267 Niverville MB R0A 1E0 Date Received: Report Date: Version: 27-APR-16 14:57 (MT) FINAL Client Phone: 204-392-3012 Certificate of Analysis Lab
More informationList of Analytical Methods for Trade Waste
List of Analytical Methods for Trade Waste Contaminant Acetaldehyde Acetone Aluminium Store on ice or refrigerate. 0.5 mg/l USEPA 8315A Store on ice or refrigerate. 40 mg/l USEPA 8315A Ammonia (NH 3 -N)
More informationCALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing
CALIFORNIA STATE ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing Basic Laboratory, Inc. 2218 Railroad Avenue Redding, CA 96001 Phone: (530) 243-7234 Field of Testing: 101 -
More informationWest Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division
West Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division to perform analyses for the purpose of determining compliance with the requirements of the state's
More informationEnvironmental Management System
Environmental Management System Moreton Bay Research Station (MBRS) Water Management Program 1. Program Scope The Water Management Program incorporates all the water used throughout the Moreton Bay Research
More informationNitrogen, Simplified TKN (s-tkn ) DOC
Nitrogen, Simplified Total Kjeldahl, TNTplus 880, 10242 DOC316.53.01258 s-tkn Method Method 10242 0 to 16 mg/l TKN TNTplus 880 Scope and Application: For water and wastewater. Digestion is required. Test
More informationThe photolab 6000 Series Spectral analysis universal and flexible
The photolab 6000 Series Spectral analysis universal and flexible The spectrophotometers of the photolab 6000 series for VIS and UV/VIS range offer the unique combination of systematic and spectral analysis
More informationPhotometer PF-12. Compact photometer PF-12
Water Analysis Photometer PF-12 Compact photometer PF-12 Maximum flexibility More than 100 preprogrammed methods Automatic wavelength adjustment Backlit graphic display with intuitive user guidance Data
More informationPrakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat
Prakruti Environmental Engineers (Environmental ), Last Amended on - Page 1 of 7 I. WATER 1. Water (Ground Water/ Surface Water/ Drinking Water/ Treated Water) ph APHA 4500-H + B, Temperature APHA 2550
More informationPrecise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure
Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Reliable water analysis Precise & Affordable A complete product line of Spectrophotometers, Colorimeters and Turbidity
More informationReagents and standards for the Pharmaceutical Industry
Reagents and standards for the Pharmaceutical Industry European Pharmacopoeia (Ph. Eur.) 8th Edition Reagents as outlined in Chapter 4 (4.1.1) of Ph. Eur. Product No. Description Pack Size 1000401 Acetic
More information