Reagents. Specifications and Certificate of Analysis. Green chemistry. Tablet reagents. Tube tests

Size: px
Start display at page:

Download "Reagents. Specifications and Certificate of Analysis. Green chemistry. Tablet reagents. Tube tests"

Transcription

1 Reagents Green chemistry For decades, the Tintometer Group has been known as a producer of reagents for water analysis, which are supplied under the brand name Lovibond. The wide range of applications requires different types of reagents. Also, users tend to have personal preferences as to which dosage system to use. Our broad product range covers blistered tablet reagents, powder reagents packed in aluminium foil and precise dosing liquid reagents in dropper bottles. With all our reagents, we strive to keep the formulations as environmentally friendly as possible. Hazardous substances are whenever possible replaced by harmless and functionally identical substitutes. Where the required chemistry of the detection method makes the use of these substances absolutely necessary, the concentration levels are lowered to the minimum rate, without compromising the accuracy of the analysis results. For example, our reagents for Pool & Spa water testing are free from boric acid, which is still frequently being used as an additive in the industry. The European Union (EU) has classified boric acid as a dangerous substance. The Lovibond DPD No. 1 tablets are not only 100% free from boric acid, they also guarantee compliance with the buffering effect required by the standard. This characteristic makes the tablet a leader in its field. Tablet reagents Our test tablets are manufactured in Germany under tightly controlled conditions on most modern machinery. Maintaining the highest quality standards permits Tintometer to guarantee our tablet reagents for a minimum of 5 years, and some for as long as 10 years. We can make this promise because each tablet is hermetically sealed within an individual aluminium foil pocket, protecting against challenging environmental conditions. This packaging keeps each tablet in perfect condition, right up until the time it is needed by the user. Test tablets remain the most consistent and reliable reagent format available, consistently outperforming other reagent formats, and delivering maximum accuracy for the user. The aluminium foil blister packaging brings added convenience to the tradition of protection achieved in the Lovibond long established tablet production technology. With the blister strip, the user just pushes the tablet through the protective foil, straight into the sample. Simple, time-saving and practical. This type of packaging, long established in pharmaceutical applications, combines all the advantages of protective foil, with convenience for the user. There are no safety risks if the tablets are used in line with the instructions supplied. Safety data sheets are available for all reagents. Specifications and Certificate of Analysis To express the high quality standard of Lovibond tablet reagents, specifications for each type of tablet as well as a Certificate of Analysis for each lot is available in the down-load area at Tube tests Lovibond tube tests enable the user to easily perform highly sensitive and precise water testing. When using tube tests measurement is considerably faster and easier, particularly in the case of standard and serial tests. The tube tests contain a precisely measured amount of reagent, thereby avoiding the presence of superfluous chemicals and optimising test safety. Up to six different measuring ranges are available for the various tests. The tubes are made of special optical glass with a 16 mm in diameter. They are supplied in a storage and dispatch box together with the digestion or auxiliary reagents. This packaging unit contains 24 or 25 reaction vials and up to 2 zero vials for photometer system calibration General Catalogue March 2017

2 Liquid reagents As a rule, liquid reagents do not consist of a single preparation but comprise several components that need to be added to the sample in a certain order. As both the size and the number of drops have a decisive effect on the resultant colour complex, the reagents need to be added with a high degree of precision. The shelf life of liquid reagents is reduced by temporary contact with oxygen in the air when the bottle is opened as well as by unsuitable storage environments (presence of sunlight or high temperatures). Provided that the bottles are stored within the temperature range +6 C to +10 C, the Lovibond DPD and Phenol Red solutions can be used for a period of two years from the production date. VARIO Powder Packs The fast and easy use of VARIO Powder Packs has made them extremely popular for water testing applications in many countries throughout the world. The Lovibond Powder Pack programme provides users with a real alternative to existing measurement systems. The Vario Powder Packs are produced to the same high quality standards that have made Tintometer's tablet reagents so successful for several decades. Parameters from aluminium and chlorine through to sulphate are just some of the well-known tests that are included in the VARIO Powder Pack range. Their chemical properties make them compatible to Hach devices. * Detailed information see pages Membrane filter set For use when preparing samples for photometric measurements Advantages removes turbid materials from samples differentiates between dissolved and total substances 0.45 µm mesh meets the requirements of the official German unitary procedure for water testing To prevent the effects of light scatter, it must be ensured that all turbid materials are removed from the sample before photometric measurements are carried out. This can be achieved with the Lovibond membrane filter set. Where certain methods are employed (e.g., iron, manganese, CSB, etc.) a membrane filter set must be used to differentiate samples in terms of dissolved and total substances. The filter mesh size of 0.45 µm is in accordance with the official German unitary procedure for water testing. Order code: (covers 25 x 0.45 µm membrane filters and two 20 ml syringes) Photometry * HACH is a registered trademark of Hach Company, Loveland, Colorado. The use of the HACH trademark does not imply any affiliation with or approval by Hach Company regarding the formulation, testing or compatibility of these products for use in HACH brand spectrophotometers or other devices or systems. 83 General Catalogue March 2017

3 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Alkalinity-M mg/l Acid/Indicator 1, 2, 5 24 mm ø Alkalinity-M HR mg/l Acid/Indicator 1, 2, 5 24 mm ø Alkalinity-P mg/l Acid/Indicator 1, 2, 5 24 mm ø Aluminium VARIO mg/l Eriochrome cyanine R 2 24 mm ø Aluminium mg/l Eriochrome cyanine R 2 24 mm ø Ammonia mg/l Indophenole blue 2, 3 24 mm ø Ammonia VARIO mg/l Salicylate 2 24 mm ø Ammonia VARIO LR mg/l Salicylate 2 16 mm ø Ammonia VARIO HR 1-50 mg/l Salicylate 2 16 mm ø Arsenic (III, V) mg/l Silver diethyldithiocarbamate 1 20 mm o MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 84 General Catalogue March 2017

4 Display Reagent Form of reagent/quantity Order code CaCO 3 ALKA-M-PHOTOMETER Tablet / BT CaCO 3 ALKA-M-HR-PHOTOMETER Tablet / BT CaCO 3 ALKA-P-PHOTOMETER Tablet / BT Al VARIO Aluminum ECR/F20 Powder Pack / 100 VARIO Aluminum Hexamine/F20 Powder Pack / 100 VARIO Aluminum ECR Masking Reagent Liquid reagent / 25 ml Set Al ALUMINIUM No. 1 Tablet / BT ALUMINIUM No. 2 Tablet / BT Combi pack # ALUMINIUM No.1 / No.2 each BT Combi pack # ALUMINIUM No.1 / No.2 each BT Photometry NH 4 - N AMMONIA No. 1 Tablet / BT AMMONIA No. 2 Tablet / BT Combi pack # AMMONIA No.1 / No.2 each BT Combi pack # AMMONIA No.1 / No.2 each BT Ammonia conditioning powder (for seawater) Powder / 15 g / 50 Tests NH 4 - N VARIO Ammonia Salicylate F10 Powder Pack / 100 VARIO Ammonia Cyanurate F10 Powder Pack / 100 Set NH 4 - N VARIO Ammonia Salicylate F5 Powder Pack / 50 VARIO Ammonia Cyanurate F5 Powder Pack / 50 VARIO Am Diluent Reagent LR Reaction tube / 50 VARIO Deionised Water (for Zero) Bottle, 100 ml Set (Tube test) NH 4 - N VARIO Ammonia Salicylate F5 Powder Pack / 50 VARIO Ammonia Cyanurate F5 Powder Pack / 50 VARIO Am Diluent Reagent HR Reaction tube / 50 VARIO Deionised Water (for Zero) Bottle, 100 ml Set (Tube test) As for chemicals see manual, reagents at specialized chemistry dealer a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 85 General Catalogue March 2017

5 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Biguanide (see PHMB) Boron mg/l Azomethine 3 24 mm ø Bromine mg/l DPD 5 24 mm ø mg/l mm o mg/l mm o mg/l mm ø Bromine Powder mg/l DPD 1, 2 24 mm ø Cadmium (Cd 2+ ) mg/l Cadion 16 mm ø Chloride mg/l Silver nitrate/turbidity 24 mm ø mg/l i) Chloride 5-60 mg/l Iron (III)-thiocyanate 4 24 mm ø Chloride mg/l Mercury thiocyanate / 24 mm ø Iron nitrate Chlorine a) mg/l DPD 1, 2 24 mm ø mg/l mm o mg/l mm o mg/l mm ø Chlorine HR (DPD) a) mg/l DPD 1, 2 24 mm ø MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 86 General Catalogue March 2017

6 Display Reagent Form of reagent/quantity Order code B BORON No. 1 Tablet / BORON No. 2 Tablet / BT Combi pack # BORON No.1 / No.2 each BT Combi pack # BORON No.1 / No.2 each BT Br DPD No. 1 Tablet / BT DPD No. 3 Tablet / BT Combi Pack # DPD No.1 / No.3 each BT Combi Pack # DPD No.1 / No.3 each BT DPD No. 1 HIGH CALCIUM e) Tablet / BT DPD No. 3 HIGH CALCIUM e) Tablet / BT Combi Pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT Combi Pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT DPD Nitrite Tablet / GLYCINE f) Tablet / BT Combi pack # DPD No.1 / GLYCINE each BT Combi pack # DPD No.1 / GLYCINE each BT Photometry Br Chlorine TOTAL-DPD/F10 Powder Pack / Cd Spectroquant d) Tube test / Cl CHLORIDE T1 Tablet / BT CHLORIDE T2 Tablet / BT Combi pack # CHLORIDE T1 / T2 each BT Combi pack # CHLORIDE T1 / T2 each BT Cl Chlorid-51 / Chlorid-52 Reagent test (Liquid reagent) approx Tests Cl KS251 (Chloride Reagent A) Liquid reagent / 65 ml 56L KS253 (Chloride Reagent B) Liquid reagent / 65 ml 56L Set 56R Cl 2 DPD No. 1 Tablet / BT DPD No. 3 Tablet / BT Combi pack # DPD No.1 / No.3 each BT Combi pack # DPD No.1 / No.3 each BT DPD No. 1 HIGH CALCIUM e) Tablet / BT DPD No. 3 HIGH CALCIUM e) Tablet / BT Combi Pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT Combi Pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT Cl 2 DPD No. 1 HR Tablet / BT DPD No. 3 HR Tablet / BT a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 87 General Catalogue March 2017

7 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Chlorine a) mg/l DPD 1, 2 24 mm ø mg/l mm ø Chlorine Powder MR 0,02-3,5 mg/l DPD 1, 2 24 mm ø Chlorine Powder a) mg/l DPD 1, 2 24 mm ø mg/l mm ø multy vial Chlorine HR (KI) mg/l KI / Acid 5 16 mm ø Chlorine dioxide mg/l DPD/Glycine 1,2 24 mm ø mg/l mm o mg/l mm ø Chlorine dioxide Powder mg/l DPD 1, 2 24 mm ø Chromium (III, VI) b) mg/l ,5-Diphenylcarbozide 1, 2 50 mm o mg/l mm ø COD LR (ISO 15705:2002) b) mg/l Dichromate / H 2 SO 4 1, 2 16 mm ø COD MR (ISO 15705:2002) b) mg/l Dichromate / H 2 SO 4 1, 2 16 mm ø COD HR b) mg/l Dichromate / H 2 SO 4 1, 2 16 mm ø Copper a) mg/l Biquinoline 4 24 mm ø mg/l mm o mg/l mm ø mg/l mm ø MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 88 General Catalogue March 2017

8 Display Reagent Form of reagent/quantity Order code Cl 2 DPD 1 Buffer solution Liquid reagent / 15 ml DPD 1 Reagent solution Liquid reagent / 15 ml DPD 3 Solution Liquid reagent / 15 ml Set Cl 2 VARIO Chlorine FREE-DPD/F10 Powder Pack / VARIO Chlorine TOTAL-DPD/F10 Powder Pack / Cl 2 VARIO Chlorine FREE-DPD/F10 Powder Pack / VARIO Chlorine TOTAL-DPD/F10 Powder Pack / Cl 2 ACIDIFYING GP Tablet / BT CHLORINE HR (KI) Tablet / BT Combi pack # CHLORINE HR (KI)/ACIDIFYING GP each BT Combi pack # CHLORINE HR (KI)/ACIDIFYING GP each BT Photometry ClO 2 DPD No. 1 Tablet / BT DPD No. 3 Tablet / BT Combi pack # DPD No.1 / No.3 each BT Combi pack # DPD No.1 / No.3 each BT GLYCINE f) Tablet / BT Combi pack # DPD No.1 / GLYCINE each BT Combi pack # DPD No.1 / GLYCINE each BT DPD No. 1 HIGH CALCIUM e) Tablet / BT DPD No. 3 HIGH CALCIUM e) Tablet / BT Combi Pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT Combi Pack # DPD No.1 / No.3 HIGH CALCIUM e) each BT ClO 2 Chlorine FREE-DPD/F10 Powder Pack / GLYCINE f) Tablet / BT Cr PERSULF. RTG FOR CR Powder Pack / Chromium Hexavalent Powder Pack / O 2 Reaction tube mg/l Tube test / Reaction tube mg/l, mercury free* Tube test / *without chloride removal O 2 Reaction tube mg/l Tube test / Reaction tube mg/l, mercury free* Tube test / *without chloride removal O 2 Reaction tube mg/l Tube test / Reaction tube mg/l, mercury free* Tube test / *without chloride removal Cu COPPER No. 1 Tablet / BT COPPER No. 2 Tablet / BT Combi pack # COPPER No.1 / No.2 each BT Combi pack # COPPER No.1 / No.2 each BT a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 89 General Catalogue March 2017

9 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Copper a) mg/l Bicinchoninate 24 mm ø Copper, free VARIO mg/l Bicinchoninate 24 mm ø Cyanide mg/l Pyridine-barbituric acid 1 24 mm ø mg/l mm o Cyanuric acid mg/l Melamine 24 mm ø DEHA µg/l PPST 3 24 mm ø DEHA VARIO µg/l PPST 3 24 mm ø Fluoresceine (only MD 640) ppb > 395 Fluorescence 24 mm ø Fluoride mg/l SPADNS 2 24 mm ø mg/l Formaldehyde 1-5 mg/l H 2 SO 4 / Chromotropic acid 10 mm o mg/l mm o Formaldehyde mg/l H 2 SO 4 / Chromotropic acid 16 mm ø Hardness, calcium mg/l Murexide 4 24 mm ø Hardness, calcium mg/l Murexide 4 24 mm ø Hardness, total 2-50 mg/l Metallphthalein 3 24 mm ø mg/l i) Hazen (Pt-Co-units ; APHA) mg/l Direct reading 1, 2 24 mm ø mg/l mm o MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 90 General Catalogue March 2017

10 Display Reagent Form of reagent/quantity Order code Cu KS240 (Coppercol Reagent 1) Liquid reagent / 30 ml 56L KS241 (Coppercol Reagent 2) Liquid reagent / 30 ml 56L KS242 (Coppercol Reagent 3) Powder / 10 g 56L COPPER No.2 Tablet / BT Set 56R Cu Vario Cu 1 F10 Powder Pack / CN Cyanid-11 / Cyanid-12 / Cyanid-13 Reagent test (Powder, Liquid reagent) / 200 Tests Cys CyA-TEST Tablet / BT DEHA DEHA Solution Liquid reagent / 100 ml DEHA Tablet / BT Photometry DEHA VARIO OXYSCAV 1 RGT Powder Pack / 200 VARIO DEHA 2 RGT Solution / 100 ml Set Fluoresceine no reagents required F SPADNS Reagent Liquid reagent / 250 ml Liquid reagent / 500 ml Fluoride Standard Solution / 30 ml Reagent solution and standard required HCHO Spectroquant d) Reagent test / ca Tests HCHO Spectroquant d) Tube test / CaCO 3 CALCHECK Tablet / BT CaCO 3 Combi pack # CALCIO H No.1 / No.2 each BT Combi pack # CALCIO H No.1 / No.2 each BT CaCO 3 HARDCHECK P Tablet / BT Tablet / BT Pt-Co-units no reagents required - - a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 91 General Catalogue March 2017

11 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Hydrazine mg/l Dimethylamino- 24 mm ø benzaldehyde 3 Hydrazine mg/l Dimethylamino- 24 mm ø mg/l benzaldehyde 3 Hydrazine c) mg/l PDMAB 24 mm ø Hydrogen peroxide mg/l DPD/Catalyst 5 24 mm ø mg/l mm o mg/l mm ø Hydrogen peroxide 1-50 mg/l Peroxotitanium acid 24 mm ø mg/l i) Iodine mg/l DPD 5 24 mm ø Iron (II, III) mg/l PPST 3 24 mm ø soluble mg/l mm o mg/l mm o Iron VARIO (II, III) mg/l ,10-Phenanthroline 2 24 mm ø soluble mg/l Iron VARIO, total g) mg/l TPTZ g) 24 mm ø mg/l Iron LR (Fe 2+/3+ ) mg/l Ferrozine / Thioglycolate 24 mm ø mg/l 530 Iron LR 2 (Fe 2+ and Fe 3+ ) mg/l Ferrozine / Thioglycolate 24 mm ø Iron HR mg/l Thioglycolate 24 mm ø MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 92 General Catalogue March 2017

12 Display Reagent Form of reagent/quantity Order code N 2 H 4 Hydrazine Test Powder Powder / 30 g Spoon N 2 H 4 VARIO Hydra 2 Rgt Solution Solution / 100 ml N 2 H 4 Vacu-vial j) Test Kit / Adapter for Vacu-vials j) H 2 O 2 HYDROGENPEROXIDE LR Tablet / BT H 2 O 2 H 2 O 2 reagent solution Liquid reagent / 15 ml Photometry I DPD No. 1 Tablet / BT Fe IRON LR (Fe 2+ and Fe 3+ ) Tablet / BT IRON (II) LR (Fe 2+ ) Tablet / BT Fe VARIO Ferro F10 Powder Pack / Fe VARIO IRON TPTZ F10 Powder Pack / Fe KS61 (Ferrozine / Thioglycolate, FE5) Liquid reagent / 65 ml 56L KS63 (Thioglycolate Reagenz, FE6) Liquid reagent / 65 ml 56L KP962 (Ammonia Persulphate Powder) Powder 56P KS135 (Phenolphthalein / Indicator) Liquid reagent / 65 ml 56L KS144 (Calcium Hardness Buffer) Liquid reagent / 65 ml 56L Fe KS60 FE1 (Acetate Buffer) Liquid reagent / 65 ml 56L KS63 FE6 (Thioglycolate Reagent) Liquid reagent / 65 ml 56L KS65 FE7 (Ferrozine Reagent) Liquid reagent / 65 ml 56L Set 56R Fe KS160 TH2 FE8 (Total Hardness Buffer) Liquid reagent / 65 ml 56L KS63 FE6 (Thioglycolate Reagent) Liquid reagent / 65 ml 56L Set 56R a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 93 General Catalogue March 2017

13 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Iron, total, Fe in Mo mg/l Fe in Mo 24 mm ø Lead (Pb 2+ ) mg/l (2-Pyridylazo)-resorcine 10 mm o Lead (Pb 2+ ) mg/l (2-Pyridylazo)-resorcine 16 mm ø Manganese mg/l Formaldoxime 24 mm ø Manganese VARIO LR mg/l PAN 24 mm ø Manganese VARIO HR mg/l Periodate oxidation 2 24 mm ø Manganese mg/l Formaldoxime 24 mm ø Molybdate / Molybdenum 1-50 mg/l Thioglycolate 4 24 mm ø 1-30 mg/l mg/l Molybdate / Molybdenum mg/l Mercaptoacetic acid 24 mm ø VARIO LR mg/l Molybdate / Molybdenum mg/l Mercaptoacetic acid 24 mm ø VARIO HR mg/l Molybdate / Molybdenum HR mg/l Thioglycolate 4 24 mm ø mg/l Nickel mg/l Dimethylglyoxime 2, 3 50 mm o mg/l mm ø MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 94 General Catalogue March 2017

14 Display Reagent Form of reagent/quantity Order code Fe VARIO (Fe in Mo) Rgt 1 Powder Pack / VARIO (Fe in Mo) Rgt 2 Powder Pack / Set Pb Spectroquant d) Reagent test / 50 Tests Pb Spectroquant d) Tube test / Mn MANGANESE LR 1 Tablet / BT MANGANESE LR 2 Tablet / BT Combi pack # MANGANESE LR 1 / LR 2 each BT Combi pack # MANGANESE LR 1 / LR 2 each BT Mn VARIO Ascorbic Acid Powder Pack / 100 VARIO Alkaline-Cyanide Liquid reagent / 60 ml VARIO PAN Indicator Liquid reagent / 60 ml Set VARIO Rochelle Salt Solution h) 30 ml Photometry Mn VARIO Manganese Citrate Puffer F10 Powder Pack / 100 VARIO Sodiumperiodate F10 Powder Pack / 100 Set Mn KS265 Manganese Reagent A Liquid reagent / 30 ml 56L KS266 Manganese Reagent B Liquid reagent / 30 ml 56L KS267 Manganese Reagent C Liquid reagent / 30 ml 56L Set 56R MoO 4 MOLYBDATE No.1 HR Tablet / BT MoO 4 MOLYBDATE No.2 HR Tablet / BT Mo Combi pack # MOLYBDATE No.1 HR / No.2 HR each BT Combi pack # MOLYBDATE No.1 HR / No.2 HR each BT MoO 4 VARIO Molybdenum 1 LR F20 Powder Pack / 100 Mo VARIO Molybdenum 2 LR Liquid reagent/ 50 ml required accessory: Set mixing cylinder (not included) MoO 4 VARIO Molybdenum HR1 F10 Powder Pack / 100 Mo VARIO Molybdenum HR2 F10 Powder Pack / 100 VARIO Molybdenum HR3 F10 Powder Pack / 100 Set MoO 4 KS63 (Thioglycolate Reagent) Liquid reagent / 65 ml 56L Ni Nickel-51, Nickel-52 Reagent test (Powder, Liquid reagent) / 50 Tests a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 95 General Catalogue March 2017

15 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Nickel mg/l Nioxime 24 mm ø Nitrate mg/l Zinc reduction / NED 24 mm ø 0,35-4,4 mg/l Nitrate VARIO 1-30 mg/l Chromotropic acid 16 mm ø 4,4-132 mg/l Nitrate mg/l ,6-Dimethylphenole 3 16 mm ø 2,2-62 mg/l Nitrite mg/l N-(1-Naphthyl)- 24 mm ø 0,03-0,16 mg/l ethylenediamine 2,3 Nitrite mg/l Sulfanilic/Naphthylamine 1 16 mm ø 0,1-2 mg/l mg/l mg/l 545 Nitrite LR VARIO mg/l Diazotation 24 mm ø 0,03-1 mg/l Nitrogen-total b) mg/l ,6-Dimethylphenole 2,3 16 mm ø mg/l i) Nitrogen VARIO, mg/l Persulphate- 16 mm ø total LR b) digestion method Nitrogen VARIO, mg/l Persulphate- 16 mm ø total HR b) digestion method MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 96 General Catalogue March 2017

16 Display Reagent Form of reagent/quantity Order code Ni NICKEL No.1 Tablet / BT NICKEL No.2 Tablet / BT NO 3 - N NITRATE TEST Powder Powder / 15 g NO 3 NITRATE TEST Tablet Tablet / NITRITE LR Tablet / BT Nitrate test tube NO 3 - N VARIO Nitrate Chromotropic Powder Pack / 50 NO 3 VARIO Nitra X Reagent tube Reaction tube / 50 VARIO Deionised Water (for Zero) Bottle, 100 ml Set (Tube test) NO 3 - N Reaction tube, Nitrat-111 Tube test NO 3 Liquid reagent / 24 Photometry NO 2 - N NITRITE LR Tablet / BT NO 2 NO 2 - N Reaction tube, Nitrit-101 Tube test (Powder) / NO 2 NO 2 - N NO 2 NO 2 - N VARIO Nitri 3 Powder Pack / NO 2 N Digestion reagent, Tube test (Powder, Compensation reagent, Nitrat-111 Liquid reagent) / 24 N VARIO TN HYDROX. LR Tubes Digestion tubes / 50 VARIO PERSULFATE Reagent Powder Pack / 50 VARIO TN Reagent A Powder Pack / 50 VARIO TN Reagent B Powder Pack / 50 VARIO TN ACID LR/HR Tubes Reaction tubes / 50 VARIO Deionised Water (for Zero) Bottle, 100 ml Set (Tube test) N VARIO TN HYDROX. HR Tubes Digestion tubes / 50 VARIO PERSULFATE Reagent Powder Pack / 50 VARIO TN Reagent A Powder Pack / 50 VARIO TN Reagent B Powder Pack / 50 VARIO TN ACID LR/HR Tubes Reaction tubes / 50 VARIO Deionised Water (for Zero) Bottle, 100 ml Set (Tube test) a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 97 General Catalogue March 2017

17 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Oxygen, activ mg/l DPD Oxygen, dissolved c) µg/l Rhodazine D TM 13 mm ø Ozone mg/l DPD/Glycine 5 24 mm ø mg/l mm o mg/l mm ø Phenols mg/l Aminoantipyrine 1 24 mm ø PHMB (Biguanide) 2-60 mg/l Buffer/Indicator 24 mm ø Phosphate-total LR b) mg/l Phosphomolybdic acid/ 16 mm ø mg/l Ascorbic acid 2 Phosphate-total HR b) mg/l Phosphomolybdic acid/ 16 mm ø 5-60 mg/l Ascorbic acid 2 Phosphate LR, ortho ,3 mg/l Phosphomolybdic acid/ 24 mm ø mg/l Ascorbic acid 2 Phosphate HR, ortho 0,33-26 mg/l Vanadomolybdate 2 24 mm ø 1-80 mg/l Phosphate VARIO ortho ,83 mg/l Phosphomolybdenum blue/ 24 mm ø mg/l Ascorbic acid 2 Phosphate VARIO ortho ,6 mg/l Phosphomolybdenum blue/ 16 mm ø mg/l Ascorbic acid 2 Phosphate-ortho 1-20 mg/l Vanadomolybdate 2 16 mm ø 3-60 mg/l MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond 98 General Catalogue March 2017

18 Display Reagent Form of reagent/quantity Order code O 2 DPD No. 4 Tablet / BT O 2 Vacu-vial j) Liquid reagent / Adapter for Vacu-vials j) O 3 DPD No. 1 Tablet / BT DPD No. 3 Tablet / BT Combi pack # DPD No.1 / No.3 each BT Combi pack # DPD No.1 / No.3 each BT GLYCINE f) Tablet / BT Combi pack # DPD No.1 / GLYCINE each BT Combi pack # DPD No.1 / GLYCINE each BT C 6 H 5 O H PHENOLE No. 1 Tablet / BT PHENOLE No. 2 Tablet / BT Photometry PHMB PHMB PHOTOMETER Tablet / BT PO 4 - P Reaction tube, Phosphat-101, Tube test (Powder, PO 4 Phosphat- 102, Phosphat-103 Liquid reagent) / 24 PO 4 - P Reaction tube, Phosphat-101, Tube test (Powder, PO 4 Phosphat-102, Phosphat-103 Liquid reagent) / 24 PO 4 - P PHOSPHATE No. 1 LR Tablet / BT PO 4 PHOSPHATE No. 2 LR Tablet / BT Combi pack # PHOSPHATE No.1 LR / No.2 LR each BT PO 4 - P PHOSPHATE No. 1 HR Tablet / BT PO 4 PHOSPHATE No. 2 HR Tablet / BT Combi pack # PHOSPHATE No.1 HR / No.2 HR each BT PO 4 - P VARIO PHOSPHATE RGT, F10 Powder Pack / PO 4 PO 4 - P VARIO Dilution Vial 50 Tubes PO 4 VARIO PHOSPHATE RGT, F10 Powder Pack / 50 VARIO Deionised Water (for Zero) Bottle, 100 ml Set (Tube test) PO 4 - P Reaction tube Tube test / PO 4 a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 99 General Catalogue March 2017

19 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Phosphate VARIO b) acid hydrolyzable: Acid digestion 16 mm ø acid hydrolyzable mg/l Phosphomolybdenum blue/ and total mg/l Ascorbic acid 2 total: Acid-/ 16 mm ø mg/l Persulphate digestion mg/l Phosphomolybdic acid/ Ascorbic acid 2 Phosphate VARIO total b) mg/l Acid-/ 16 mm ø Persulphate digestion mg/l Ascorbic acid 2 16 mm ø Phosphate, ortho c) 1,6-13 mg/l Vanadomolybdate mg/l Phosphate, ortho c) ,6 mg/l Stannous chloride mg/l Phosphate LR ,3 mg/l Phosphomolybdic acid/ 24 mm ø mg/l Ascorbic acid 2 Phosphate HR, ortho 1,63-26 mg/l Vanadomolybdate 2 24 mm ø 5-80 mg/l Phosphonate VARIO mg/l Persulfate UV-Oxidation 24 mm ø ph value Bromcresol purple 5 24 mm ø ph value Phenol red 5 24 mm ø ph value Phenol red 5 24 mm ø ph value Thymol blue 5 24 mm ø MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond General Catalogue March 2017

20 Display Reagent Form of reagent/quantity Order code VARIO Acid Reagent Vial 50 Tubes PO 4 - P VARIO PHOSPHATE RGT, F10 Powder Pack / 50 PO 4 VARIO Deionised Water (for Zero) Bottle, 100 ml 1N NaOH Bottle / 100 ml PO 4 - P 1,54 N NaOH Bottle / 100 ml PO 4 VARIO Potassium Persulfate F10 Powder Pack / 50 Set (Tube test) PO 4 - P VARIO Acid Reagent Vial 50 Tubes VARIO PHOSPHATE RGT, F10 Powder Pack / 50 PO 4 VARIO Deionised Water (for Zero) Bottle, 100 ml 1,54 N NaOH Bottle / 100 ml VARIO Potassium Persulfate F10 Powder Pack / 50 Set (Tube test) PO 4 - P Vacu-vial j) Test Kit / PO 4 Adapter for Vacu-vials j) Photometry PO 4 - P Vacu-vial j) Test Kit / PO 4 Adapter for Vacu-vials j) PO 4 - P KS80 (CRP Reagent) Liquid reagent / 2 x 65 ml 56L PO 4 KP119 (Ascorbic acid) Powder / 20 g 56P Set 56R PO 4 - P KS228 (Ammonia Molybdate) Liquid reagent / 65 ml 56L PO 4 KS229 (Ammonia Metavanadate) Liquid reagent / 65 ml 56L Set 56R Option Polyphosphate KS278 (50 % Sulfuric Acid) Liquid reagent / 65 ml 56L KS135 (Phenolphthalein Indicator) Liquid reagent / 65 ml 56L KS144 (Calcium Hardness Buffer) Liquid reagent / 65 ml 56L KP962 (Ammonium Persulphate Powder) Powder / 40 g 56P PO 4 VARIO Potassium Persulfate F10 Powder Pack / 100 VARIO PHOSPHATE RGT, F10 Powder Pack / 200 Set ph BROMOCRESOLPURPLE/PHOTOMETER Tablet / BT ph PHENOLRED / PHOTOMETER Tablet / BT ph PHENOLRED Solution Liquid reagent / 15 ml ph THYMOLBLUE / PHOTOMETER Tablet / BT a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 101 General Catalogue March 2017

21 Reagents Test Range Method Cuvette MD 200 MD 100 & MD 110 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Polyacrylates 1-30 mg/l Turbidity 24 mm ø Potassium mg/l Tetraphenylborate- 24 mm ø 1-10 mg/l Turbidity 4 24 mm ø PTSA (only MD 640) ppb > 395 Fluorescence 24 mm ø Silica mg/l Silicomolybdate 2,3 24 mm ø mg/l Silica VARIO LR mg/l Heteropolyblue 2 24 mm ø Silica VARIO HR 1-90 mg/l Silicomolybdate 2,3 24 mm ø mg/l mm ø Silica mg/l Heteropolyblue 2 24 mm ø Sodiumhypochlorite % Potssium iodide 5 24 mm ø Spectral 0-50 m Direct reading 1 50 mm o Absorption-coefficient ISO 7887: Sulphate VARIO mg/l Bariumsulphate Turbidity 2 24 mm ø mg/l mg/l MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond General Catalogue March 2017

22 Display Reagent Form of reagent/quantity Order code Polyacryl KS255 (Polyacrylate Reagent 1) Liquid reagent / 65 ml 56L KS256 (Polyacrylate Reagent 2) Liquid reagent / 65 ml 56L Set 56R KS336 (Propan-2-ol) Liquid reagent / 65 ml 56L C18 (Cartouche) 56A KS173 (2,4 Dinitrophenol) Liquid reagent / 65 ml 56L KT183 (Nitric Acid) Liquid reagent / 65 ml 56L K POTASSIUM T Tablet / PTSA no reagents required SiO 2 SILICA No. 1 Tablet / BT SILICA No. 2 Tablet / BT Combi pack # SILICA No.1 / No.2 each BT Combi pack # SILICA No.1 / No.2 each BT SILICA PR Tablet / BT Photometry SiO 2 VARIO Amino Acid F10 Powder Pack / 100 VARIO Citric Acid F10 Powder Pack / 200 VARIO Molybdate 3 Reagent solution Liquid reagent / 2 x 50 ml Set SiO 2 VARIO Silica HR Molybdate F10 VARIO Silica HR Acid Rgt F10 Powder Pack / 100 Powder Pack / 100 VARIO Silica HR Citric Acid F10 Powder Pack / 100 Set SiO 2 KS104 (Silica Reagent 1) Liquid reagent / 65 ml 56L KS105 (Silica Reagent 2) Liquid reagent / 65 ml 56L KP106 (Silica Reagent 3) Powder / 10 g 56P Set 56R NaOCl ACIDIFYING GP Tablet / BT CHLORINE HR (KI) Tablet / BT Combi pack # CHLORINE HR (KI)/ACIDIFYING GP each BT Combi pack # CHLORINE HR (KI)/ACIDIFYING GP each BT Dilution set for sample preparation 1 set no reagents required - - SO 4 VARIO Sulpha 4 / F10 Powder Pack / a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 103 General Catalogue March 2017

23 Reagents Test Range Method Cuvette MD 100 & MD 110 MD 200 Wave lengths λ / nm MD 600, MD 610 & MD 640 MultiDirect PM 620 & PM 630 PM 600 SpectroDirect Sulphate mg/l Bariumsulphate Turbidity 2 24 mm ø Sulphide mg/l DPD/Catalyst 3, 4 24 mm ø Sulphite mg/l DTNB 24 mm ø mg/l mm o mg/l mm ø Surfactants (anionic) 0,05-2 mg/l Methylene blue 1 16 mm ø Surfactants (cationic) 0,05-1,5 mg/l Disulphine blue 16 mm ø Surfactants (non ionic) 0,1-7,5 mg/l TBPE 16 mm ø Suspended solids mg/l Turbidity/Attenuated Radiation 24 mm ø mm o TOC b) 5-80 mg/l H 2 SO 4 / Indicator 16 mm ø TOC b) mg/l H 2 SO 4 / Indicator 16 mm ø Triazoles 1-16 mg/l Catalyzed UV Digestion 24 mm ø (UV lamp requested) Turbidity Attenuated Radiation Method 50 mm o Attenuated Radiation Method 24 mm ø Urea mg/l Urease / Indophenol 24 mm ø mg/l i) mg/l Zinc mg/l Zincon 3 /EDTA 24 mm ø mg/l Zinc mg/l Zincon 3 /EDTA 24 mm ø MSDS (Material Safety Data Sheets): For other reagent quantities please see our current price list. Legend 1 Deutsche Einheitsverfahren zur Wasser-, Abwasser- und Schlamm- Untersuchung 2 Standard Methods for the Examination of Water and Wastewater, 18th Edition; Photometrische Analysenverfahren, Schwedt, Wissenschaftliche Verlagsgesellschaft mbh, Stuttgart; Photometrische Analyse, Lange/Vejdelek, Verlag Chemie; Colorimetric Chemical Analytical Methods, 9th Edition, Lovibond General Catalogue March 2017

24 Display Reagent Form of reagent/quantity Order code SO 4 SULFATE T Tablet / BT S SULFIDE No. 1 Tablet / SULFIDE No. 2 Tablet / SO 3 SULFITE LR Tablet / BT MBAS Spectroquant Tube test / CTAB Spectroquant Tube test / Triton X-100 Spectroquant Tube test / Photometry - no reagents required - - TOC Spectroquant d) Tube test / Aluminium screwcaps / 6 pc TOC Spectroquant d) Tube test / Aluminium screwcaps / 6 pc Benzotriazole VARIO Triazole Rgt F25 Powder Pack / FAU no reagents required - - FAU CH 4 N 2 O UREA Reagent 1 Liquid reagent / 15 ml UREA Reagent 2 Liquid reagent / 10 ml AMMONIA No. 1 Tablet / BT AMMONIA No. 2 Tablet / BT Combi pack # AMMONIA No.1 / No.2 each BT Combi pack # AMMONIA No.1 / No.2 each BT UREA PRETREAT Tablet / BT (compensates for the interference of free Chlorine up to 2 mg/l) UREA Reagent Set, contains: Set BT UREA Reagent 1/2, AMMONIA No.1/2, UREA PRETREAT Zn COPPER/ZINC LR Tablet / BT EDTA Tablet / BT DECHLOR (in case of high levels of residual chlorine) Tablet / BT Zn KS243 (Zinc Reagent 1) Liquid reagent / 65 ml 56L KP244 (Zinc Reagent 2) Powder / 20 g 56L Set 56R a) determination of free, combined and total b) Thermoreactor is necessary for COD (150 C), TOC (120 C) and total -chromium, - phosphate, -nitrogen, (100 C) c) MultiDirect: Adapter is necessary for Vacu-vials (Order code ) d) Spectroquant is a Merck KGaA Trademark e) alternative reagent, used instead of DPD No.1 / DPD No.3 in case of turbidity in the water sample caused by high concentration of calcium and/or high conductivity f) additionally required for determination of bromine, chlorine dioxide and ozone in the presence of chlorine g) Reagent recovers most insoluble iron oxides without digestion h) additionally required for samples with hardness values above 300 mg/l CaCO 3 i) high range by dilution j) Vacu-vials is a Chemetrics Trademark # including stirring rod 105 General Catalogue March 2017

Specification and Certificate of Analysis

Specification and Certificate of Analysis Reagents Green chemistry For decades, the Tintometer Group has been known as a producer of reagents for water analysis, which are supplied under the brand name Lovibond. The wide range of applications

More information

Photometry. Reagents

Photometry. Reagents Wave lengths λ / nm Test Range Method Cuvette AL100 AL250 AL250+ AL400 AL450 AL800 Acid capacity KS4.3 0.1-4 mmol/l - - 605 610 610 615 Acid/Indicator 1, 2 24 mm ø Alkalinity-m (total) 5-200 mg/l 610-605

More information

AQUALYTIC. Parameter, Ranges and Reagents for. Chloride 530 Silver nitrate/turbidity mg/l Cl

AQUALYTIC. Parameter, Ranges and Reagents for. Chloride 530 Silver nitrate/turbidity mg/l Cl AQUALYTIC Parameter, Ranges and Reagents for Test λ a) / nm Method Range Display Alkalinity-m (total) 610 Acid/Indicator 1, 2 5-200 mg/l CaCO 3 Alkalinity-p 560 Acid/Indicator 1, 2 5-500 mg/l CaCO 3 Aluminium

More information

Reagents. Development. Tablet reagents. specifications and Certificate of analysis. Tube tests

Reagents. Development. Tablet reagents. specifications and Certificate of analysis. Tube tests Development For more than thirty years, Tintometer in Dortmund has been manufacturing reagents for water testing and marketing these reagents around the world under the brand name Lovibond. Different forms

More information

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis Reagents Development For more than thirty years, AQUALYTIC has been manufacturing reagents for water testing and marketing these reagents around the world. Different forms of reagents are required for

More information

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis

Reagents. Development. Tablet reagents. Specifications and Certificate of Analysis Reagents Development For more than thirty years, AQUALYTIC has been manufacturing reagents for water testing and marketing these reagents around the world. Different forms of reagents are required for

More information

Tintometer -Group. Reagents. Development. DPD reagents. Tablet reagents. Specifications and Certificate of Analysis

Tintometer -Group. Reagents. Development. DPD reagents. Tablet reagents. Specifications and Certificate of Analysis Tintometer -Group Reagents Development For more than thirty years, Tintometer in Dortmund has been manufacturing reagents for water testing and marketing these reagents around the world under the brand

More information

Available tests for the photometer MD600 / MaxiDirect New Tests

Available tests for the photometer MD600 / MaxiDirect New Tests Available tests for the photometer MD600 / MaxiDirect New s 20 Acid demand ph 4.3 T 610 Acid / Indicator 1, 2 0.1-4 mmol/l ALKA-M PHOTOMETER 513210BT 30 Alkalinity-m T (total) 610 Acid / Indicator 1, 2

More information

Photometer-System using Dual Beam Technology

Photometer-System using Dual Beam Technology Tintometer Photometer-System using Dual Beam Technology Dual Beam Technology and Interference Filters for best accuracy 44 Applications Waste Water Drinking Water Industrial Process Water Scientific Applications

More information

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers DelAgua Safe Water Reagent Identification Chart for Lovibond Tintometer photometers For Use: Identify the parameter required, ensure the parameter matches your photometer, codes required for the test are

More information

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries

Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries Thermo Scientific Orion AquaMate Master Methods List - Thermo Scientific Orion AQUAfast Reagent Chemistries Please visit our website at thermofisher.com/mastermethods for the latest instructions for Thermo

More information

Spectrophotometer AL800/SpectroDirect

Spectrophotometer AL800/SpectroDirect Spectrophotometer AL800/SpectroDirect GB Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must

More information

MC500 Multi-Parameter Colorimeter

MC500 Multi-Parameter Colorimeter MC500 Multi-Parameter Colorimeter Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Keep reagents out

More information

SP600. Spectrophotometer. Instruction Manual

SP600. Spectrophotometer. Instruction Manual SP600 Spectrophotometer Instruction Manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the

More information

Instruction Manual GB

Instruction Manual GB Instruction Manual GB Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the hands of children.

More information

Photometer-System P 620. Instruction manual

Photometer-System P 620. Instruction manual Photometer-System P 620 GB Instruction manual Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into

More information

Instruction Manual GB

Instruction Manual GB Instruction Manual GB Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis and must not be used for any other purpose. Reagents must not get into the hands of children.

More information

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water.

Comparator The system for colorimetric water analysis. Applications. Water Treatment (e.g. Drinking Water) Pool-Water. Comparator 2000+ The system for colorimetric water analysis Applications Water Treatment (e.g. Drinking Water) Pool-Water Research Centres Universities Special Applications Laboratory and Field Testing

More information

Thermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter. User Guide

Thermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter. User Guide Thermo Scientific Orion AQUAfast AQ3700 Colorimetry Meter User Guide ROSS and the COIL trade dress are trademarks of Thermo Fisher Scientific Inc. U.S. patent 6,793,787. AQUAfast, Cahn, ionplus, KNIpHE,

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Copper T 0.05-5 mg/l Cu a) Biquinoline 150 Cu Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Iron 10 T mg/l Fe Ferrozine / Thioglycolate

Iron 10 T mg/l Fe Ferrozine / Thioglycolate Iron 10 T 0.05-1 mg/l Fe Ferrozine / Thioglycolate 218 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Silicate HR VARIO PP 1-100 mg/l SiO 2 Silicomolybdate 352 SiHr Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range

More information

Copper 50 T mg/l Cu a) Biquinoline

Copper 50 T mg/l Cu a) Biquinoline Copper 50 T 0.05-1 mg/l Cu a) Biquinoline 149 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

Sustainability and environmental protection. Tintometer places great importance on sustainability and the sensitive use of natural resources.

Sustainability and environmental protection. Tintometer places great importance on sustainability and the sensitive use of natural resources. Tintometer -Group There are very few companies which can look back over a history of more than 125 years of success. The reason we can do so lies in the world-wide appreciation of our products and the

More information

Lovibond Water Testing. Tintometer Group. General Catalogue. General Catalogue. Instruments and Reagents for Today s Water Analysis.

Lovibond Water Testing. Tintometer Group. General Catalogue. General Catalogue. Instruments and Reagents for Today s Water Analysis. General Catalogue Lovibond Water Testing Tintometer Group General Catalogue Instruments and Reagents for Today s Water Analysis www.lovibond.com PHILOSOPHY Water is the basis of life. And it also provides

More information

Comparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards

Comparator Colorimeter for regular testing in public pools & spas with colour-stable glass standards Comparator 2000+ Colorimeter for regular testing in public pools & spas with colour-stable glass standards 24 www.lovibond.com Pool & Spa Water Testing - January 2013 Comparator 2000+ With its accessories,

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Hardness Calcium (B) T 0-500 mg/l CaCO 3 Murexide 191 CAH Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range

More information

Portable photometer for field and laboratory use

Portable photometer for field and laboratory use Portable photometer for field and laboratory use MACHEREY-NAGEL www.mn-net.com MN Application with VISOCOLOR reagents The photometer PF-11 offers an easy start into photometric water analysis. When evaluated

More information

HACH CHEMISTRIES, REAGENTS AND STANDARDS

HACH CHEMISTRIES, REAGENTS AND STANDARDS HACH CHEMISTRIES, REAGENTS AND STANDARDS Hach has more than 60 years of history dedicated to formulating and packaging highquality reagents for water analysis. We understand your applications and formulate

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Chlorine VARIO PP a) 0.02-3.5 mg/l Cl 2 DPD 113 CL2 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Bromine T 0.05-13 mg/l Br 2 DPD 80 Br Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are

More information

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated. Chlorine T a) 0.01-6.0 mg/l Cl 2 DPD 100 CL6 Instrument specific information The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer

More information

INSTRUCTION MANUAL. ba76126e01 03/2013. photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y

INSTRUCTION MANUAL. ba76126e01 03/2013. photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y INSTRUCTION MANUAL photoflex Series TEST INSTRUCTIONS AND SPECIFICATIONS, PROG. V 2.02 Y photoflex Series For the most recent version of the manual, please visit www.ysi.com. Contact Copyright YSI 1725

More information

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Reliable water analysis Precise & Affordable A complete line of Spectrophotometers, Colorimeters and Turbidity

More information

Water Analysiss. Solutions for photometry

Water Analysiss. Solutions for photometry Water Analysiss Reag gents OR Reag NANOCOLOR OR Solutions for photometry Bar coded tube tests with pre-dosed reagents For highest accuracy and sensitivity in water analysis NANOCONTROL for analytical quality

More information

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside!

Laboratory & Field Instruments: Sample Cells. Sample Cells. See Inside! Laboratory & Field Instruments: See Inside! Quick Reference Guide See pages 86-87. for Spectrophotometers and Colorimeters See pages 88-90. for Turbidimeters See pages 90. Pour-Thru See pages 91. Quick

More information

HACH LCK CUVETTE TEST SYSTEM

HACH LCK CUVETTE TEST SYSTEM HACH LCK CUVETTE TEST SYSTEM Hach offers a perfectly coordinated system of photometers and reagents, required accessories and services. For all key parameters from Ammonium to Zirconium. Systematic quality

More information

Photometer PC 22. Operating Instructions

Photometer PC 22. Operating Instructions Photometer PC 22 GB Operating Instructions Front View Lid Stopper Cell Cell compartment LCD-Display Keypad Back View 9-pole D sub-coaxil connector Charging socket for mains supply Battery compartment with

More information

DR 1900 PORTABLE SPECTROPHOTOMETER

DR 1900 PORTABLE SPECTROPHOTOMETER DR 1900 PORTABLE SPECTROPHOTOMETER Applications Drinking Water Wastewater Field Use Industrial Water Power Carry more water methods with you wherever you need them most. The DR 1900 combines the ruggedness

More information

Test sticks and test papers for semi-quantitative determinations

Test sticks and test papers for semi-quantitative determinations QUANTOFIX test sticks for semi-quantitative determinations QUANTOFIX test sticks meet the most important requirements for a modern quick-test: rapid dip and read convenient the analysis can be carried

More information

Why Hach Reagents? Alphabetical Listing of Reagents

Why Hach Reagents? Alphabetical Listing of Reagents Why Hach Reagents? Hach Chemical Reagents Formulated to minimize interferences, test complexity and analysis time Confirmed test performance by chemists who understand your application Designed for Maximum

More information

NEW. Multiparameter Photometers. with Advanced Optics and ph Meter

NEW. Multiparameter Photometers. with Advanced Optics and ph Meter NEW Multiparameter Photometers with Advanced Optics and ph Meter Multiparameter Photometers The HI83300 family of multiparameter photometers features nine models to cover a wide variety of applications.

More information

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Page A2 A4 A6 A20 A1 Single Parameter Simple and Economical Analysis HANNA instruments test kits are the

More information

Thermo Scientific Orion AQUAfast AQ3700 Colorimeter

Thermo Scientific Orion AQUAfast AQ3700 Colorimeter Thermo Scientific Orion AQUAfast AQ3700 Colorimeter Featuring tests for nitrogen, phosphate and COD NEW Reagents for AQ3700 New Test Range, mg/l Reagent Type AC3002AD Acid demand ph 4.3 0.1 to 4 Tablet

More information

DR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis

DR/800. Series Colorimeters. High-Value, High-Capability Instruments for Water Quality Analysis DR/800 Series Colorimeters High-Value, High-Capability Instruments for Water Quality Analysis DR/800 Series Colorimeters Hach DR/800 Series Colorimeters combine ease of use, multiple testing capabilities

More information

Determination Art. No. Total range Cell size [mm]

Determination Art. No. Total range Cell size [mm] Spectroquant Prove The following methods with the corresponding method numbers are programmed into the photometer. The measurements can be made without any further adjustments. In addition several applications

More information

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure

Precise & Affordable. Reliable water analysis. Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Water Analysis Instruments Thermo Scientific Orion AquaMate and AQUAfast Product Brochure Reliable water analysis Precise & Affordable A complete product line of Spectrophotometers, Colorimeters and Turbidity

More information

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part

More information

Kits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT

Kits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT Kits Item Product name Article Number 1 ACIDITY TEST AQUAMERCK 1.11108.0001 2 ALCOHOL TEST 15-150 MG/L REFLECTOQUANT 1.17946.0001 3 ALKALINITY TEST AQUAMERCK 1.11109.0001 4 ALUMINIUM TEST 0.020-1.20 MG/L

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Pool & Spa Water Treatment and Analysis The handbook includes detailed information

More information

GeneralCatalogue. GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents. Edition: April 2018

GeneralCatalogue. GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents. Edition: April 2018 Edition: April 2018 GeneralCatalogue GeneralCatalogue WaterAnalysis EnvironmentalAnalysis TestEquipment Reagents AQUALYTIC is a leading manufacturer of equipment for water and wastewater analysis, specializing

More information

Be sensitive. Spectroquant test kits Assured quality. New sulfate, silicate and chloride test kits

Be sensitive. Spectroquant test kits Assured quality. New sulfate, silicate and chloride test kits Spectroquant test kits Assured quality For swift, secure analysis, there s no better choice than Spectroquant test kits. Consisting of validated, standard-compliant reagents, the kits are pre-programmed

More information

HI801 iris Spectrophotometer

HI801 iris Spectrophotometer HI801 Spectrophotometer with advanced split beam optical system, customizable methods and rechargeable battery iris portable spectrophotometer is unlike any of the products we have created in the past.

More information

Method Analytical principle Relation to standards. Ammonium Gas diffusion/ ph-indicator DIN EN ISO (Ammonia)

Method Analytical principle Relation to standards. Ammonium Gas diffusion/ ph-indicator DIN EN ISO (Ammonia) FIA List of Methods Release: 24.03.2016 Total Pyrocatechol violet APHA 3500 Al modified Aluminium 0.01 mg/l 0.05... 0.5 mg/l Al-T Water / Wastewater 0.2... 2 mg/l Al-T Ammonium Gas diffusion/ ph-indicator

More information

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

HI Multiparameter Photometers with up to 44 Measurement Methods.  ISO 9001:2000 Certified HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to 44 Measurement Methods ISO 9001:2000 Certified www.hannainst.com/usa HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to

More information

ALKALINITY (ALKAPHOT)

ALKALINITY (ALKAPHOT) PHOT.2.AUTO TEST INSTRUCTIONS ALKALINITY (ALKAPHOT) TEST FOR TOTAL ALKALINITY IN NATURAL AND TREATED WATERS Photometer Method AUTOMATIC WAVELENGTH SELECTION 0 500 mg/l CaCO 3 Natural and treated waters

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10129 ORGANIC CARBON, TOTAL, Low Range (0.0 20.0 mg/l C) Direct Method * For water, drinking water, and wastewater HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103-105 C. Note: See DRB 200

More information

9100 UV-Vis Spectrophotometer

9100 UV-Vis Spectrophotometer 9100 UV-Vis Spectrophotometer Palintest 9100 UV-Vis Spectrophotometer UV-Vis spectroscopy from Palintest Ltd utilises the full range of formulated applications for drinking water, wastewater and industrial

More information

3. Add 0.4 ml of. 7. Use a TenSette

3. Add 0.4 ml of. 7. Use a TenSette Method 10173 ORGANIC CARBON, TOTAL, Mid Range (15 150 mg/l C) Direct Method * For wastewater and industrial waters HRS MIN SEC 1. Turn on the DRB 200 reactor. Heat to 103 105 C. Note: See DRB 200 user

More information

Water and Food Analytics. Test Kits, Instruments and Accessories

Water and Food Analytics. Test Kits, Instruments and Accessories Water and Food Analytics Test Kits, Instruments and Accessories How can I obtain sound analytical results quickly and reliably? Quite simply: Take advantage of more than 100 years of experience in chemical

More information

Instruments and Reagents for Water Analysis

Instruments and Reagents for Water Analysis Instruments and Reagents for Water Analysis Table of Contents Methods of Analysis...2 Quick Reference by Parameter...4 Visual Systems MiniKits / Test Kits......6 Aqua Comparator...8 Comparator and Nesslerizer

More information

Haryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Haryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide

More information

MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL

MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL MULTIPARAMETER PHOTOMETERS POOL AND SPA WASTEWATER DRINKING WATER PROCESS WATER SOIL About us Palintest is a leading company in the design and manufacture of water analysis technologies, supplying a comprehensive

More information

IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING

IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING Micro 0 Revision 0// 8700-K Standard Kit 8700-WD Well Driller Kit 8700-KP Pool Kit Dual Wavelength Advanced Photometer System IDEAL FOR DRINKING WATER, POOLS & SPAS, ENVIRONMENTAL, AND EDUCATIONAL TESTING

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Pool & Spa Water Treatment and Analysis The handbook includes detailed information

More information

Parameters from A-Z. Visual and instrumental test kits at a glance

Parameters from A-Z. Visual and instrumental test kits at a glance Parameters from A-Z Visual and instrumental test kits at a glance What options do the Merck rapid tests have to offer for the determination of the concentration of individual parameters? The following

More information

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh Madhya Pradesh Waste Management Project, Certificate Number TC-5022 (in lieu of T-2449) Page 1 of 8 CHEMICAL TESTING I. POLLUTION AND ENVIRONMENT 1. Waste Water (Effluent & Sewage) ph APHA 22nd Edition,

More information

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents.

Lovibond Water Testing. Tintometer Group. Pool & Spa Water Analysis. Instruments and Reagents. Lovibond Water Testing Tintometer Group Pool & Spa Water Analysis Instruments and Reagents www.lovibond.com Lovibond -Handbook Swimming and Spa Pool Water Treatment The handbook includes detailed information

More information

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2011. Edition: 11/07

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2011. Edition: 11/07 Pool & Spa Water Analysis Instruments and Reagents Edition: 03/2011 Edition: 11/07 Lovibond -Handbook Swimming and Spa Pool Water Treatment The handbook includes detailed information on topics relating

More information

AUTOMATED WATER ANALYSIS

AUTOMATED WATER ANALYSIS APPLICATION NOTE - CFA AUTOMATED WATER ANALYSIS APPLICATIONS OF CONTINUOUS-FLOW ANALYZERS In laboratories around the world, the SEAL Analytical analyzers measure all types of water - quickly, accurately

More information

Overview of parameters from A-Z page All test kits at a glance. Visual test kits. ph test strips and papers page 14-17

Overview of parameters from A-Z page All test kits at a glance. Visual test kits. ph test strips and papers page 14-17 Overview of parameters from A-Z page 2-13 All test kits at a glance Visual test kits ph test strips and papers page 14-17 ph determination made easy Merckoquant page 18-25 The universal test strip for

More information

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore

OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS. Shane Jordan-Hill. Merck Millipore OBSERVATIONS OF AN OPERATOR IN THE LAB IMPROVING LABORATORY RESULTS Paper Presented by: Shane Jordan-Hill Author: Shane Jordan-Hill, Business Manager Environmental Analysis, Merck Millipore 6 th Annual

More information

GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents

GeneralCatalogue. WaterAnalysis EnvironmentalAnalysis. TestEquipment Reagents GeneralCatalogue WaterAnalysis EnvironmentalAnalysis TestEquipment Reagents AQUALYTIC is a leading manufacturer of equipment for water and wastewater analysis, specializing in BOD measurement and photometry.

More information

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2009. Edition: 11/07

Pool & Spa Water Analysis. Instruments and Reagents. Edition: 03/2009. Edition: 11/07 Pool & Spa Water Analysis Instruments and Reagents Edition: 03/2009 Edition: 11/07 Pool- & Spa Water Testing Instruments and Reagents for reliable Water Analysis There are very few companies which can

More information

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY THE WATER ACT, 1956 (ACT 54 OF 1956 ) AND ITS REQUIREMENTS IN TERMS OF WATER SUPPLIES FOR DRINKING WATER AND FOR WASTE WATER TREATMENT AND DISCHARGE INTO THE ENVIRONMENT 1. INTRODUCTION The provisions

More information

European Pharmacopoeia Solutions

European Pharmacopoeia Solutions European Pharmacopoeia Solutions European Pharmacopoeia Solutions Reagecon, as a specialist manufacturer of laboratory reagents has now introduced the range of Reagents and Standard solutions in Chapters

More information

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater; REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : ENVIRONMENTAL DATA - Temperature min. : C - Temperature max. : C - Altitude (m.a.s.l) : m - Plant location (geographic area, seismic zone,

More information

C 99 & C 200 Series Multiparameter Bench Photometers

C 99 & C 200 Series Multiparameter Bench Photometers Instruction Manual C 99 & C 200 Series Multiparameter Bench Photometers Manufacturers since 1978 These Instruments are in Compliance with the CE Directives 1 Dear Customer, Thank you for choosing a Hanna

More information

Method (0.1 to 8.0 mg/l Cu) TNTplus 860

Method (0.1 to 8.0 mg/l Cu) TNTplus 860 Chlorine, Total, Bulk Powder, 8167 DOC316.53.01255 Bathocuproine Method 1 Method 10238 (0.1 to 8.0 mg/l Cu) TNTplus 860 Scope and Application: For water, wastewater and process water. Digestion may be

More information

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation Matrix: CWA (Non Potable Water) Discipline EPA 120.1 Chemistry Conductivity 8/1/2015 Aluminum 8/1/2015 Antimony 8/1/2015 Arsenic 8/1/2015 Barium 8/1/2015 Beryllium 8/1/2015 Boron 8/1/2015 Cadmium 8/1/2015

More information

Schedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent

Schedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent LABORATORY LOCATION: (PERMANENT LABORATORY) Page: 1 of 12 SPECTRUM LABORATORIES (PENANG) SDN. BHD. 1904 TINGKAT 1, JALAN BUKIT MINYAK TAMAN SRI MANGGA, 14000 BUKIT MERTAJAM SEBERANG PRAI TENGAH PULAU PINANG

More information

NANOCOLOR tube tests. Precise rapid tests for photometric water analysis. Good to know

NANOCOLOR tube tests. Precise rapid tests for photometric water analysis. Good to know Precise rapid tests for photometric water analysis for photometric analysis convince by their easy handling and therefore are the first choice for routine, laboratory and process analysis. A maximum in

More information

Lovibond The Instruments of Choice The Test of Quality. Instruction/Operator Manual

Lovibond The Instruments of Choice The Test of Quality. Instruction/Operator Manual Lovibond The Instruments of Choice The Test of Quality Instruction/Operator Manual V2_2009 GB 2 PoolDirect 9in1_2 09/2008 Safety precautions CAUTION Reagents are formulated exclusively for chemical analysis

More information

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal Last Amended on - Page 1 of 16 I. WATER 1. Drinking Water ph IS 3025 (Part 2): 2004, Colour APHA (22 nd Edition) 2120 B: Turbidity (NTU) IS 3025 (Part 10): 1984 Residual, Free Chlorine IS 3025 Part 26/1986

More information

BOD Measurement. Cabinets. Photometer. Page 60 I Incubators. Page 56 I AL606. Page 6 I AL100. Page 10 I AL250. Page 56 I AL612

BOD Measurement. Cabinets. Photometer. Page 60 I Incubators. Page 56 I AL606. Page 6 I AL100. Page 10 I AL250. Page 56 I AL612 Content Photometer BOD Measurement Cabinets Page 6 I AL100 Page 56 I AL606 Page 60 I Incubators Page 10 I AL250 Page 56 I AL612 Page 62 I Spark-free cabinets Page 16 I AL250COD VARIO Page 18 I AL400 Page

More information

Water and Food Analytics. Test Kits, Instruments and Accessories

Water and Food Analytics. Test Kits, Instruments and Accessories Water and Food Analytics Test Kits, Instruments and Accessories Absolute reliability is essential in water and food analytics. When the task is to maintain and improve the quality of life, even the slightest

More information

Reagents and standards for the Pharmaceutical Industry

Reagents and standards for the Pharmaceutical Industry Reagents and standards for the Pharmaceutical Industry European Pharmacopoeia (Ph. Eur.) 8th Edition Reagents as outlined in Chapter 4 (4.1.1) of Ph. Eur. Product No. Description Pack Size 1000401 Acetic

More information

HANNA LITERATURE. Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry

HANNA LITERATURE. Water Treatment Process Swimming Pools Agriculture Food Laboratory Thermometry HANNA LITERATURE Hanna publishes a wide range of catalogs and handbooks for an equally wide range of applications. The reference literature currently covers areas such as: Water Treatment Process Swimming

More information

with IP67 BOOTH #2832

with IP67 BOOTH #2832 with IP67 4 BOOTH #2832 The new exact idip by Industrial Test Systems, Inc. (ITS is the first product in the recreational water testing market to provide complete wireless connectivity between the iphone,

More information

European Pharmacopoeia

European Pharmacopoeia European Pharmacopoeia Pharma Standards John Barron Page 1 of 6 Reagents and standards for the Pharmaceutical Industry European Pharmacopoeia (Ph. Eur.) 8th Edition Reagents as outlined in Chapter 4 (4.1.1)

More information

MULTIPARAMETER ION SPECIFIC METERS

MULTIPARAMETER ION SPECIFIC METERS Instruction Manual MULTIPARAMETER ION SPECIFIC METERS Manufacturers since 1978 These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna product. Please read

More information

Checker. Handheld Colorimeters

Checker. Handheld Colorimeters Checker Handheld Colorimeters Features Easier to use and more accurate than chemical test kits High accuracy Large, easy to read digits Auto shut off Eliminates subjectivity Dedicated to a single parameter

More information

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m

More information

Photometer PF-12. Compact photometer PF-12

Photometer PF-12. Compact photometer PF-12 Water Analysis Photometer PF-12 Compact photometer PF-12 Maximum flexibility More than 100 preprogrammed methods Automatic wavelength adjustment Backlit graphic display with intuitive user guidance Data

More information

Analysis of dissolved nitrite (NO 2- )

Analysis of dissolved nitrite (NO 2- ) Analysis of dissolved nitrite (NO 2 ) Table of content 1. PURPOSE... 2 2. PRINCIPLE... 2 3. REQUIREMENTS... 3 3.1. EQUIPMENT AND MATERIALS... 3 3.2. REAGENTS... 3 4. PROCEDURE... 3 4.1. SAMPLE PREPARATION...

More information

Nitrogen, Simplified TKN (s-tkn ) DOC

Nitrogen, Simplified TKN (s-tkn ) DOC Nitrogen, Simplified Total Kjeldahl, TNTplus 880, 10242 DOC316.53.01258 s-tkn Method Method 10242 0 to 16 mg/l TKN TNTplus 880 Scope and Application: For water and wastewater. Digestion is required. Test

More information

COLORIMETERS HACH POCKET COLORIMETER II. Fluoride 0.1 to 2.0 mg/l H

COLORIMETERS HACH POCKET COLORIMETER II. Fluoride 0.1 to 2.0 mg/l H COLORIMETERS PLEASE NOTE: We offer Hach products as a convenience to our customers. We do not make recommendations for, or troubleshoot problems with Hach products. We do not make any recommendations as

More information

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3) NORTH TEXAS MUNICIPAL WATER DISTRICT - Wylie Water Analysis Jan-2018 Mineral Analysis Raw Treated Standards Residue on Evaporation 412 456 500 1000 Silica (SiO2) 3.63 3.41 Iron (Fe) 0.378 0.259 0.3 0.3

More information

2019 Microbac Laboratories Inc. Ohio Valley Division

2019 Microbac Laboratories Inc. Ohio Valley Division STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES LABORATORY CERTIFICATION BRANCH In accordance with the provisions of N.C.G.S. 143-215.3 (a) (1), 143-215.3 (a)(10)

More information