Continuous corrosion, monitoring of crude overhead systems

Size: px
Start display at page:

Download "Continuous corrosion, monitoring of crude overhead systems"

Transcription

1 Continuous corrosion, monitoring of crude overhead systems 1. Introduction Present high levels of production and the ease of availability of light tight oils (so called LTOs) are driving US refiners to enhance their processing flexibility to take advantage of the significantly higher margins that can be achieved from processing of these oils. While considerable focus is being placed on the ability of the crude and vacuum distillation towers to cope with a marked change in yield slate from these crudes from a tower loading and fractionation standpoint, these LTOs also exhibit unique processing issues from a corrosion point of view. The production of LTOs relies on the use of (so called) fracking fluids, a cocktail of chemicals to stimulate oil to flow from the field. In many instances, these chemicals can end up in the crude oil as feedstock to the refinery. In addition, the transportation of light tight oils by railcar requires the addition of H 2 S passivator chemicals that can introduce other corrosion-related problems to refineries. These amine-based compounds can deposit as salts in the top section of crude towers, around the top pumparound and draw trays, with the resulting possibility of under deposit corrosion. To counter these issues, many operators are adding acidic chemicals to their desalter wash water to neutralise the amines. However, without careful monitoring and control, this operation in itself opens up the potential for increased corrosion over a wider area of the crude distillation unit. As well as LTOs, many operators are exploring a wider crude slate basket and testing new crudes, with the possibility for introduction of other corrosive species, such as organic acids (chlorides) into the crude unit, which are usually residues from chemicals used for well stimulation in the upstream oil production process. While dew point corrosion in the crude overhead systems is well documented, the processing of LTOs at a refinery can increase the risk to plant integrity from elevated corrosion across a wider area of the crude overheads system. This can result in unplanned shutdowns driven by unacceptably high corrosion activity. However, if unnoticed and unmitigated, this increased corrosion rate could lead to a hydrocarbon leak and, in the worst case, result in an explosion or fire, which may cause human tragedy, extended business interruption, loss of customers, the cost of extensive rebuilding of equipment, as well as the impact on the company's brand reputation, and future enhanced regulatory scrutiny. Unplanned outages in a critical process unit, such as the crude distillation, will often cancel out the profit gained from processing a price-advantaged crude diet, so refiners have to walk the narrow tightrope between maximising profit and managing plant on-stream availability. Compound this with 1 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

2 pressure to reduce costs, most notably through reduced headcount and contractor use, often including inspection department resources, and the ability of a refiner to maintain an appropriate level of surveillance of plant integrity is further challenged. Oil and gas facility operators the world over are solving this puzzle by proactively deploying at scale, permanently installed, continuous wall thickness monitors to track corrosion in critical locations. Not only does tighter monitoring enable cost-effective tracking of corrosion in areas of concern, but it enables a refiner to pinpoint specific feedstocks or process operations that result in accelerated corrosion rates - thereby facilitating optimisation of corrosion mitigation strategies online and validation of the effectiveness of these mitigation strategies, so that timely, evidence-based, integrity management decisions can be made. 2. The need for crude processing flexibility Figure 1: US light tight oil production (EIA) Recent data, shown in Figure 1, published by EIA, shows the rapid growth in production of US domestic light tight oil. These crudes are discounted by several $/bbl against the normal marker crudes, like Brent or WTI and refineries located in the vicinity of the major light tight oil formations have an even higher margin advantage. A conservative discount of just $0.5/bbl from the standard crude slate for an opportunity crude could raise the profitability of a typical 200 kbpd refinery by $35 Million/year; far in excess of the cost of incremental chemical inhibition and monitoring, meaning that the payback time on the implementation of an inhibition/monitoring program can often be measured in terms of a few months. 2 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

3 3. Crude tower overhead corrosion Crude tower overhead corrosion has been well studied and documented over many years. The aggressiveness of the corrosive attack in the overhead system is a function of the amount of chloride present in the system, which in turn is a function of the effectiveness of the desalter. Inadequate desalter performance results in high (salt) chloride content in the crude oil at the desalter outlet - the chloride ions hydrolyse in the crude furnace and form hydrogen chloride which is condensed in the crude overhead system. The highest risk location for failure occurs at the point where the first droplet of hydrochloric acid condenses, because this has a very low ph, known as the dew point. If ammonia and amine-based salts are present in the overhead system, and the operating conditions favour salt formation, these compounds can create a protective layer over the condensed hydrochloric acid and allow it to corrode away at the underlying metal without interruption. The hydrochloric acid dewpoint can move around within the overhead system, driven by changes to operating temperature and pressure and flowing velocity, which makes it difficult to monitor. Crude overhead system shell-and-tube condensers are traditionally designed with the overhead material on the shell side. The hydrochloric acid attack therefore occurs on the outside of the tubes - a localised leak results in crude oil (which is usually used as the cooling medium) leaking into the overhead (naphtha) product. If unchecked, this contaminated naphtha can have a significant impact on the performance and catalyst life of downstream hydrotreaters. Examples of localised dew point corrosion are shown in the photographs (Figure 2) below. Figure 2: Crude overhead hydrochloric acid dew point corrosion [Courtesy of Nalco Champion] Light tight oil processing introduces another corrosion problem for refiners - the use of amine-based H 2 S passivators can result in salt formation in the top section of the crude tower, on the inside of the tower walls on the trays, around the top pumparound circuit and in the product draw-offs. As described previously, these salts can form a protective layer over the hydrochloric acid with the result that very aggressive and localised corrosion can occur. In order to neutralise these amines, refiners are moving towards new treatment programs involving acidifying the desalter - if applied without care, this can also introduce acid-based corrosion around the desalter wash water system and in the desalter itself. Most refiners utilise a chemical treatment program for their crude overhead system, in addition to close desalter performance monitoring. Common treatments utilise two elements: 1. Neutraliser - often an amine-based compound, or ammonia, this acts to raise the ph in the overheads system and to react with any hydrochloric acid present, producing an inert amine chloride-type compound. 3 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

4 2. Filmer - this is also often an amine-based compound, which is injected to cover the surfaces inside the overhead system, thereby providing a barrier to prevent the hydrochloric acid from coming into contact with the metal. In order to dilute hydrochloric acid formed in the overhead system, many crude units also employ a continuous water wash - often control systems on these water wash facilities are basic, with no guarantee of uniformity of water distribution across the exchanger banks. This can result in operators having a false sense of security. 4. Crude overhead dew point corrosion management Refiners have two principal mitigation strategies for crude overhead acid corrosion - they can upgrade the metallurgy of many/all of the susceptible areas of the unit(s), often to high grade, expensive alloys such as hastelloy, monel or titanium or they can use chemical treatment. In both cases, these strategies should be combined with tighter corrosion monitoring at critical locations to verify the inhibitor distribution and the effectiveness of the metallurgy upgrade. The choice between these options is usually a question of capital budget availability - in the current climate, where capital budgets are being cut, many operators are choosing chemical inhibition and monitoring over metallurgical upgrading, especially since the optimisation of the inhibitors and the installation of integrity monitoring systems can be carried out on-the-run without the need for a plant shutdown. Figure 3: The choice between metallurgical upgrading and chemical treatment for crude overhead dewpoint corrosion mitigation 4 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

5 5. High risk areas for acid dewpoint attack in crude tower overheads The diagram below shows the areas of a typical crude unit that are at high risk from acid dewpoint attack: Figure 4: Crude tower overheads - high risk locations for acid dewpoint attack 6. Commonly applied technology for corrosion monitoring There are several types of instrument that have traditionally been used for monitoring corrosion in oil refineries. Two of the most common are corrosion probes and manual ultrasonic inspection Corrosion (or Electrical Resistance, ER) probes Corrosion probes have been in use since the 1960s and are a very well established technology. They rely on an intrusive element with a sacrificial tip, which sits in the process fluid and is (normally) made from the same material as the surrounding equipment. As the sacrificial tip corrodes, its electrical resistivity changes, which is recorded externally (usually on a locally mounted data logger) but these are also increasingly available wirelessly connected. The corrosion of the sacrificial tip is used to infer the level of corrosion being experienced by the surrounding equipment. While being simple to use, corrosion probes suffer from a number of disadvantages: The centre line measured corrosion may not be the same as the corrosion rate at the wall, due to the shear velocity effects described previously. The tip often corrodes away after two to three years (or even less with "high sensitivity" applications), while many refineries are now operating 5+ years between major turnarounds. Thus, the corrosion probe tip will usually need to be replaced on the run. Very careful safety procedures and intensive technician training are required to reduce danger to personnel. In spite of this, there have been several well documented safety incidents caused by probes being ejected at high velocity under residual pressure. Several international oil companies have banned removal of intrusive probes while the plant is 5 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

6 running, with the result that they operate 'blind', from a corrosion standpoint, for the final, and most critical, one or two years of the cycle between turnarounds. The intrusive nature of these probes means that they cannot be installed during normal operations, since they require specialist mounting flanges to be bored and welded to the piping. The intrusive probe creates a disturbance in the flow of the fluid that can induce corrosion to occur further downstream. Many of the older type, data logger based probes require an engineer to visit the equipment to download data. They therefore require physical access to the probe location and have an inherently low acquisition rate. This latter point is an important issue for crude overhead systems, such as the overhead line itself, as these are often physically remote the probe data connection then has to be cabled to a nearby platform, increasing installation costs and opening the possibility for the cable to be damaged Manual ultrasonic inspection Ultrasound has been applied in the oil and gas industry for the past 50 years and is a well-established technique for measuring metal wall thickness. The technique involves the generation of ultrasound from a transducer that is placed directly onto the metal surface. The ultrasound is transmitted through the metal until it is reflected off the inside metal surface (backwall). The reflected ultrasound signal (or A-scan) is recorded and the time difference (the 'time-of-flight') between the sending and reflected signals provides the measurement of the wall thickness. While the technique can be reliable, completion of a full set of measurements for a medium-sized refinery with 80,000+ corrosion measurement points is very time consuming and labour intensive, such that the wall thickness at an individual low- to medium-risk point may only be measured every 2-3 years. It is therefore very difficult to take measurements in key locations with enough frequency to measure corrosion rates with any confidence, or to link periods of high wall loss to specific feedstocks or process operations (which require measurements on the time scale of days to be useful). In addition, while being relatively simple, manual ultrasound methods have the following disadvantages: Repeatability and reproducibility errors it is highly unlikely that consecutive measurements will be taken in precisely the same location by the same NDE technician. In addition, the equipment used and the skill level of the NDE technician can vary between measurements, introducing high variability to the measurements. The chart below shows manual measurements at a single (nominal) location over time from 1984 to It is clear that different conclusions regarding wall thickness and corrosion rate can be drawn over time. From such data, it could be inferred that the accuracy of manual ultrasound is +/ 0.5 to 1 mm (+/ thou). 6 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

7 Figure 5: Manual ultrasound measurements at a fixed location over time [courtesy of Chevron] High temperatures temperatures above only 100 C (212 F) can permanently damage the electronics of the transducer. Physical access the inspector needs to be able to have access to the equipment at the measurement location of interest, therefore requiring scaffolding (possibly permanently installed) and stripping of insulation to expose the metal work to make the manual measurements. 7. Overview of the Permasense technology Permasense permanently installed, ultrasonic, wireless, wall thickness monitoring sensors are ideal for crude overhead dewpoint corrosion monitoring - having sensitivity to small changes in wall thickness, robustness to extreme plant conditions, extended battery life (enabling reliable operation over the entire cycle between turnarounds) while being simple and cost effective to install at scale. 7.1 Resilience to high temperature The design of the sensor incorporates a unique and patented 'waveguide' design as shown on the following page. The waveguides are made from stainless steel, which is a poor conductor of heat, and so the electronics are kept safely away from the hot metal surface (up to 600 C (1100 F)). 7 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

8 Figure 6: Effectiveness of Permasense patented waveguide technology to protect electronics from high temperatures The ultrasound is transmitted from the 'sending' transducer, down one waveguide and the reflection is transmitted up the other waveguide to the 'receiving' transducer. As with manual ultrasound, the 'time-of-flight' difference between the 'surface wave' signal and the first reflection from the internal metal surface provides the wall thickness measurement, as shown in the diagram below. Figure 7: Signal and wavepath of the Permasense ultrasonic sensor 8 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

9 7.2 Resolution of roughness effects Permasense have recently announced the availability in Data Manager v5 of a major advance to their technology with the arrival of the proprietary AXC (Adaptive Cross Correlation) ultrasonic signal processing method. AXC makes use of the previous recorded waveform to improve the resilience of the measurement when the internal metal surface morphology is very rough, where normal ultrasonic wall thickness measurements can break down. In addition, AXC further enhances the repeatability of the measurements, meaning that even smaller levels of corrosion or erosion can be detected in a matter of days. AXC enables the separation of the wall thickness measurement from the onset of roughening of the internal surface - however, the presence of roughness is now captured separately as a colour bar, known as the Permasense Shape Indicator, or PSI. This improved processing method makes the interpretation of the data much easier and quicker. 8. Local measurements/area coverage The Permasense system is designed to have a low cost of installation, through use of wireless communications and battery power-packs, avoiding any need for cabling with the resultant armouring and cable tray installation. This simplicity of installation makes these sensors ideal for use in remote locations which are only accessible during turnarounds. Each sensor has a measurement footprint of an area of approximately 1 cm 2, which is similar to manual ultrasound inspection. Thus, the probability of detection of localised dewpoint corrosion attack using a single sensor, would be small. In order to increase the probability of detection, sensors are installed as multi-point arrays, at the highest risk locations based on understanding of the dew point temperature, metallurgy and the equipment geometry. The number of sensors needed for each array is driven by historical inspection records, or by the proportion of the area being monitored that is expected to be affected by corrosion - the smaller the affected area as a proportion of the whole equipment being monitored, the more sensors that are required to achieve 90% confidence in detecting the onset of that localised corrosion activity Confidence in detection % 20% 15% 10% of area monitored exhibiting corrosion activity No. of sensors Figure 8: Variation of number of sensors with area of corrosion and probability of detection 9 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

10 Figure 8 shows the result of mathematical analysis carried out the Department of Non-Destructive Engineering at Imperial College in London, showing the relationship between the numbers of sensors deployed in an area, the area of the corrosion activity as a proportion of the total area being monitored and the resultant probability of detection. Only a modest number of sensors are required in an area to achieve an excellent probability of detection. 9. Point measurement resolution and the effect of process temperature variations All ultrasound-based measurements are affected by process temperature variations, due to the change in speed of sound through the metal. Figure 9: Variation of wall thickness measurement with process temperature Figure 9 shows the variation of wall thickness, measured using permanently installed ultrasonic sensor. When zoomed in, as shown, the variation is of the order of 0.05 mm (2 thou), for process temperature fluctuations of 20 C (40 F). This level of variation is not ideal for determination of short term changes in corrosion rates, despite being orders of magnitude less than achievable with manual inspection. The latest generation of Permasense sensors (WT210) make use of an integrated thermocouple to measure the metal surface temperature, and can automatically compensate the wall thickness data for process temperature variations, as demonstrated in Figure 10 for the same data shown in Figure Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

11 Figure 10: Temperature compensated wall thickness measurement The temperature compensated data shows variation of less than 10 micrometres (0.2 thou). This degree of precision enables detection of much smaller, shorter term corrosion rates, with confidence. However, as importantly, the corrected data shows that corrosion was not continuous at this location and there are two discrete corrosion events, which were masked by measurement noise in the original data. The precision achievable with the latest sensor models and automated data processing is comparable to that of high sensitivity intrusive probes, but without their inherent safety problems and high installation costs. 10. Permasense monitoring solution for crude tower overhead systems Figure 11 shows an example of a monitoring system for a crude tower overhead system using the Permasense technology. A typical overhead monitoring system would consist of measurement locations, with between 2 and 5 sensors per location - so a total of 40 to 150 sensors, depending on the system configuration, metallurgy and operating conditions. 11 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

12 Figure 11: Key monitoring locations for crude tower overheads system using Permasense technology 11. Case studies Chemical treatment optimisation 'Real-time' corrosion data from Permasense sensors installed in the crude overheads system can provide an effective understanding of the effectiveness of the overhead chemical treatment program. A European refiner used a network of Permasense sensors, installed across the overhead system, to adjust the treatment chemical dosage to stabilise corrosion. Figure 12: Crude tower overheads system monitoring trend using Permasense technology Prior to optimisation of the overhead treatment chemicals, corrosion rates were very high mm/year (48 mpy). Over a month long period, the refiner increased the neutraliser dosage in steps, 12 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

13 tracking the effect on the corrosion trend provided by the Permasense sensors - once the chemical dose was optimised, the sensor data showed that the corrosion trend had been stabilised. Figure 13: Crude tower overhead line - Permasense installation Optimisation of overhead process conditions As was described earlier, the location and severity of hydrochloric acid dewpoint attack can be affected by several process parameters, such as the crude overhead cutpoint or the volume of stripping steam injected into the tower (and, hence, the volume of water condensed in the overhead system). Figure 14 shows a corrosion rate trend from Permasense sensors, correlated against the calculated volume of water condensed in the overhead exchangers. The volume of water is a function of the overhead cutpoint and other operating parameters - these are changed on a seasonal basis. The Permasense data demonstrates that when there is a sufficient volume of water condensed in the overhead exchangers, the higher the dilution of any acid droplets that condense - resulting in a higher, and less corrosive, ph. The chart also shows that the reverse is true - lower volumes of condensed water result in highly concentrated acid droplets at the dewpoint, and higher corrosion rate. Condensed Water (kgs / hr) Water Condensed in Overhead Shell and Tube Exchangers Vs. Permasense Data Outlet Temperature < Dew Point, bulk water condensation Large amount of condensed water y = x Outlet Temperature > Dew Point, localised water condensation Little/no condensed water y = x Wall Thickness (mm) Water Condensed Nov 12 Jul 13 Thickness E2102A Nov 12 Jun 13 Water Condensed Aug '13 Now Thickness E2102A Aug 13 Now Figure 14: Crude tower overhead monitoring - corrosion trend from Permasense installation 13 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

14 11.3. Treatment chemical mal-distribution One refiner noted significantly higher corrosion rates from Permasense sensors installed on the shell of one bank of exchangers from a series of banks of overhead shell-and-tube exchanger shells. This was investigated and determined to be due to an uneven distribution of the treatment chemicals. As a result, the operator prepared a small project to install a dedicated treatment chemical injection point for that exchanger bank in the next turnaround Turnaround workscope preparation A failure of an overhead exchanger bundle is a major problem for refiners - requiring an extended shutdown. In many cases, refiners keep spare overhead exchanger bundles on hand in case of a failure during normal operations, to avoid an extended delay in provisioning a new bundle from suppliers at short notice (and resulting high cost). In Case study 3 above, as a result of the high corrosion rates observed on the Permasense sensors installed on the shell of the exchanger described above, the operator was able to anticipate the need to replace the tube bundle in the work scope of a forthcoming turnaround. The equipment was ordered well in advance, with the result that this could be procured at an acceptable cost Tracking overhead system organic chloride corrosion A North American customer was able to monitor corrosion rates in the overhead system attributable to specific batches of crude using Permasense sensor data. Figure 15 shows the wall thickness trend over a six month period. The period marked by the red dot showed markedly higher corrosion rates than normal, although the crude type was not unusual and had been processed previously. During this period, there were no unusual process measurements to indicate any kind of unexpected issue with processing of this crude - apart from the high corrosion rate trend shown by the Permasense sensor data. As a result, the refiner sent samples of the crude oil to a laboratory for more advanced analysis. This showed a high (and unusual) level of organic chloride in the crude oil - most probably due to the use of well stimulant chemicals in the upstream oil production process. As a result of this experience, this refiner now routinely tests every import of crude for organic acids to pre-empt any corrosion problems. Figure 15: Crude tower overhead monitoring - corrosion trend from Permasense installation 14 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

15 11.6. Desalter wash water system corrosion A North American customer installed a Permasense sensor system to track corrosion in the desalter wash water system. This was due to the fresh wash water being fed from a nearby lake and being highly oxygenated (and hence corrosive). This application is similar in most respects to that required for effective corrosion monitoring of the desalter wash water circuit after acidification to neutralise amine passivators when processing light tight oils. 12. Conclusions Market conditions are driving refiners to seek new ways to raise profitability. This includes processing more variable quality crude oils, such as the US light tight oils (LTOs). In doing so, the risk of a corrosion driven failure is increasing, in a cost constrained environment where inspection headcount and contract resource can be limited. The growing availability of light tight oils, which have their own integrity related processing issues, is resulting in a choice between upgrading of metallurgy and chemical inhibition/corrosion monitoring. With tight budgetary constraints in place, many oil companies are opting for chemical inhibition and tighter monitoring. Payback times from an inhibition/enhanced monitoring strategy can often be measured in the order of a few months. Acid dew point attack is a localised phenomenon that occurs in the crude tower overheads. Effective monitoring requires a technology that can operate in remote locations, is able to detect small changes in internal roughness and wall loss and is simple and cost effective to install at scale. Intrusive corrosion probes have the required sensitivity and responsiveness, but are complex to install and maintain and suffer from potential safety problems when changing sacrificial probes. They represent a single point measurement that infers the impact of the corrosiveness of the process fluid on the equipment wall. Manual ultrasound suffers from repeatability/reproducibility issues due to variations between measurements in measurement location, operator and equipment. However, manual ultrasound also requires that an inspector can gain access to the location, which is not often feasible with crude tower overhead systems. Permasense technology, installed in arrays, provides both the local resolution accuracy and the required area coverage to be the perfect solution for dew point monitoring. The latest generation Permasense sensors are able to provide equivalent accuracy to 'high sensitivity' intrusive probes, by using automated temperature compensation, enabling measurement of short term changes in corrosion rates with confidence, making them ideal for tracking corrosion from short crude processing campaigns. Installed at more than 70 refineries world wide that are owned by international oil companies, independents as well as national oil companies, Permasense sensors have automatically delivered more than 10 million on line measurements over the past 5 years to 15 Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

16 those personnel who need the data to make better informed operational and asset integrity management decisions. Contact: For further information, about Permasense continuous corrosion and erosion monitoring solutions please contact us by at or by telephone to our UK offices at and or Houston office at or our Kuala Lumpur office at Permasense Ltd, Century House, 100 Station Road, Horsham, RH13 5UZ, UK

Comparison of corrosion monitoring systems

Comparison of corrosion monitoring systems Comparison of corrosion monitoring systems 1.0 Commonly applied technology for corrosion monitoring There are several types of instrument that have traditionally been used for monitoring corrosion in oil

More information

Continuous Naphthenic Acid corrosion monitoring adds crude slate flexibility

Continuous Naphthenic Acid corrosion monitoring adds crude slate flexibility Continuous Naphthenic Acid corrosion monitoring adds crude slate flexibility 1. Introduction We are presently operating in a time of very high crude price volatility. This is driving an unusual level of

More information

Non-Intrusive Corrosion and Erosion Monitoring Solutions and Case Studies. Dr. Jake Davies, ICorr Aberdeen meeting, 28th Feb 2017

Non-Intrusive Corrosion and Erosion Monitoring Solutions and Case Studies. Dr. Jake Davies, ICorr Aberdeen meeting, 28th Feb 2017 Non-Intrusive Corrosion and Erosion Monitoring Solutions and Case Studies Dr. Jake Davies, ICorr Aberdeen meeting, 28th Feb 2017 Presentation Contents Company History Drivers to monitor for corrosion and/or

More information

Continuous corrosion and erosion monitoring in geothermal power facilities

Continuous corrosion and erosion monitoring in geothermal power facilities Continuous corrosion and erosion monitoring in geothermal power facilities 1. Introduction Continuous measurement presents a step change in monitoring corrosion and erosion, the levels of corrosion rates

More information

Corrosion monitoring solution for sour water stripping units

Corrosion monitoring solution for sour water stripping units Corrosion monitoring solution for sour water stripping units 1. Overview of the sour water stripping process Many process units in a refinery, such as fluid catalytic crackers, delayed cokers, and hydrotreaters

More information

Corrosion Monitoring Solutions for Hydroprocessing Units

Corrosion Monitoring Solutions for Hydroprocessing Units Corrosion Monitoring Solutions for Hydroprocessing Units Hydroprocessing Units Key to Refinery Competitiveness The growing demand for transportation fuels and the shift toward diesel makes hydroprocessing

More information

Continuous Corrosion and Erosion Monitoring in Geothermal Power Facilities

Continuous Corrosion and Erosion Monitoring in Geothermal Power Facilities Proceedings World Geothermal Congress 2015 Melbourne, Australia, 19-25 April 2015 Continuous Corrosion and Erosion Monitoring in Geothermal Power Facilities Tom Fuggle Permasense Limited, Century House,

More information

Ultrasonic Monitoring of Corrosion with Permanently Installed Sensors (PIMS)

Ultrasonic Monitoring of Corrosion with Permanently Installed Sensors (PIMS) Ultrasonic Monitoring of Corrosion with Permanently Installed Sensors (PIMS) Frederic Cegla Abstract Ultrasonic wall thickness monitoring using permanently installed sensors has become a tool to monitor

More information

Corrosion monitoring solution for HF alkylation units

Corrosion monitoring solution for HF alkylation units Corrosion monitoring solution for HF alkylation units 1. Overview of the alkylation process Alkylation units are a key part of product upgrading in modern refineries, important to maximising profitability

More information

Continuous asset integrity monitoring supports cost reduction efforts for Canadian oil sands operators

Continuous asset integrity monitoring supports cost reduction efforts for Canadian oil sands operators Continuous asset integrity monitoring supports cost reduction efforts for Canadian oil sands operators 1. Introduction The severe fall in oil price has hit the profitability of non-integrated Canadian

More information

Corrosion: The New Process Variable Online, Real-time, Saving Money

Corrosion: The New Process Variable Online, Real-time, Saving Money Corrosion: The New Process Variable Online, Real-time, Saving Money Russell D. Kane/Honeywell Process Solutions Current estimates show the global process industries spend $50 billion annually on corrosion

More information

Pulsed Eddy Current Corrosion Monitoring in Refineries and Oil Production Facilities Experience at Shell

Pulsed Eddy Current Corrosion Monitoring in Refineries and Oil Production Facilities Experience at Shell ECNDT 006 - Fr... Pulsed Eddy Current Corrosion Monitoring in Refineries and Oil Production Facilities Experience at Shell Paul CROUZEN and Ian MUNNS, Shell Global Solutions International, Amsterdam, The

More information

Coker Safety and Reliability Lessons Learned

Coker Safety and Reliability Lessons Learned Coker Safety and Reliability Lessons Learned Dale Wilborn 2015 Coking.com Conference COKER SAFETY & RELIABILITY Current Situation The Delayed Coker industry has had many incidents with severe consequences,

More information

Mitigate Your Corrosion Risks Predictive Corrosion Management

Mitigate Your Corrosion Risks Predictive Corrosion Management Mitigate Your Corrosion Risks Predictive Corrosion Management bhge.com Predictive Corrosion Management uses our groundbreaking package of: The future of inspections is here Rightrax PM UT installed sensors

More information

I. COMPARSION OF CORROSION MONITORING SYSTEMS IN THE OIL AND GAS INDUSTRY

I. COMPARSION OF CORROSION MONITORING SYSTEMS IN THE OIL AND GAS INDUSTRY Quality on the Move! Corporate Headquarters: 2449 West Park Avenue P.O. Box 1690 Gray, LA 70359 www.nvindt.com T: 1-877-638-6841 F: 985-876-9355 info@nvindt.com I. COMPARSION OF CORROSION MONITORING SYSTEMS

More information

Installed ultrasonic sensors for asset-integrity monitoring

Installed ultrasonic sensors for asset-integrity monitoring Installed ultrasonic sensors for asset-integrity monitoring Traditionally, hand-held inspection devices such as ultrasonic thickness gages & flaw detectors, eddy current equipment and x-ray systems are

More information

Stephen M. Patera, Sales Manager, LHI Metals. October 6-9, 2013 Caesars Palace, Las Vegas, Nevada, USA

Stephen M. Patera, Sales Manager, LHI Metals. October 6-9, 2013 Caesars Palace, Las Vegas, Nevada, USA TITANIUM USED IN REFINERIES Presented by Stephen M. Patera LHI Metals Titanium Grades Most Commonly Grade 2 Grade 7 Grade 12 Grade 16 Used in Refineries Corrosive Environments HCl Hydrochloric acid NH₄Cl

More information

Experience the Benefits

Experience the Benefits Experience the Benefits Real time sensory technology and expert consultancy from SMS Cost Reduction Enhanced Safety Increased Production Performance Providing award winning expertise - making a genuine

More information

On-line corrosion mapping of industrial plant using advanced electrical resistance techniques

On-line corrosion mapping of industrial plant using advanced electrical resistance techniques UK NDT 2002 Conf. On-line corrosion mapping of industrial plant using advanced electrical resistance techniques David M. Farrell and Bernard J. Robbins Rowan Technologies Ltd. Manchester M41 9DX, England.

More information

EFFECTS OF FLOW VELOCITY ON RBI ANALYSIS OF COOLING WATER HEAT EXCHANGERS

EFFECTS OF FLOW VELOCITY ON RBI ANALYSIS OF COOLING WATER HEAT EXCHANGERS EFFECTS OF FLOW VELOCITY ON RBI ANALYSIS OF COOLING WATER HEAT EXCHANGERS Ainul Akmar Mokhtar and Azhani Zulkifli Universiti Teknologi Petronas, Bandar Seri Iskandar, Perak, Malaysia E-Mail: ainulakmar_mokhtar@utp.edu.my

More information

Ralph Navarrete and George Duggan, Baker Hughes Inc., USA,

Ralph Navarrete and George Duggan, Baker Hughes Inc., USA, Ralph Navarrete and George Duggan, Baker Hughes Inc., USA, explain how desalter ph management can help to increase crude diet flexibility. Refiners have always sought to boost their profitability by improving

More information

Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control

Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control Jim Feather ExxonMobil Research & Engineering OLI 23 rd User Conference October 5-6, 2005 Presentation Outline Challenges

More information

Mitigate Your Corrosion Risks Predictive Corrosion Management

Mitigate Your Corrosion Risks Predictive Corrosion Management Mitigate Your Corrosion Risks Predictive Corrosion Management bhge.com Predictive Corrosion Management uses our groundbreaking package of: The future of inspections is here Rightrax PM UT installed sensors

More information

Corrosion Monitoring in Cooling Water Systems

Corrosion Monitoring in Cooling Water Systems Corrosion Monitoring in Cooling Water Systems Application Note Efficient removal of heat is an economic consideration in the design and operation of cooling systems. Failure of these systems can have severe

More information

Combining Corrosion & Erosion Monitoring for Improved Integrity Management

Combining Corrosion & Erosion Monitoring for Improved Integrity Management Combining Corrosion & Erosion Monitoring for Improved Integrity Management Ionut Cadar Kjell Wold Heitor Ruschmann Ivan Ruiz Stubelj Emerson Automation Solutions Corrosion Management Why The Increased

More information

Integrating Risk-Based Inspection Recommendations with Inspection Programs and Integrity Operating Windows

Integrating Risk-Based Inspection Recommendations with Inspection Programs and Integrity Operating Windows Integrating Risk-Based Inspection Recommendations with Inspection Programs and Integrity Operating Windows Lynne Kaley, PE Principal Trinity Bridge, LLC Savannah, GA W. Clay White Fixed Equipment Network

More information

On-Line Diagnostics Techniques in the Oil, Gas, and Chemical Industry

On-Line Diagnostics Techniques in the Oil, Gas, and Chemical Industry On-Line Diagnostics Techniques in the Oil, Gas, and Chemical Industry 1. INTRODUCTION Lee Robins, Business Development Manager, Tracerco lee.robins@matthey.com Unfortunately, the vessels and pipelines

More information

AFPM 2018 Operations & Process Technology Summit

AFPM 2018 Operations & Process Technology Summit GASOLINE PROCESSES Alkylation 1 What are the benefits of alumina treating in sulfuric acid alkylation and HF alkylation? Has this technology been proven commercially? 2 What metallurgy works well and does

More information

PURASPEC JM. CLEAR Chloride guards

PURASPEC JM. CLEAR Chloride guards PURASPEC JM CLEAR Chloride guards Contents Chlorides in a refinery How should refineries handle these issues What makes an effective chloride guard A CLEAR solution to your chloride problems CLEAR PERFORM

More information

Corrosion Under Insulation Detection Methods and Inspection

Corrosion Under Insulation Detection Methods and Inspection Corrosion Under Insulation Detection Methods and Inspection June 18, 2013 NACE Section Meeting James Higgins PetroChem Inspection OVERVIEW General causes of CUI Suspect Areas- how to find and where to

More information

DOUBLE WALLED PIPING SYSTEMS

DOUBLE WALLED PIPING SYSTEMS DOUBLE WALLED PIPING SYSTEMS The design and construction of a double wall pipe is more complex than a single wall pipe because of the additional pipe, associated welds and tie in procedures. There are

More information

Pulsed Eddy-Current (PEC) Inspection through Insulation

Pulsed Eddy-Current (PEC) Inspection through Insulation INDUSTRIAL SERVICES WHITE PAPER PULSED EDDY CURRENT Pulsed Eddy-Current (PEC) Inspection through Insulation Method statement of an advanced non-destructive testing technique for inspection through insulation.

More information

Dates of Innovation Development: January, 2014 to July 2015 Web site: Summary Description: Cathodic Protection

Dates of Innovation Development: January, 2014 to July 2015 Web site:  Summary Description: Cathodic Protection 2017 Award Nomination Title of Innovation: Ultrasound Cathodic Protection Test Station Nominee(s) Eugene (Gene) B. Silverman PhD, Berkeley Springs Instruments LLC Category: Cathodic Protection Coatings

More information

Recent Advances in NDE Technologies for Turbines and Generators

Recent Advances in NDE Technologies for Turbines and Generators 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Recent Advances in NDE Technologies for Turbines and Generators Waheed A. ABBASI, Michael J. METALA SIEMENS Energy Service

More information

CML OPTIMIZATION: EFFECTIVE AND EFFICIENT COVERAGE AND PLACEMENT

CML OPTIMIZATION: EFFECTIVE AND EFFICIENT COVERAGE AND PLACEMENT ASSET INTEGRITY INTELLIGENCE CML OPTIMIZATION: EFFECTIVE AND EFFICIENT COVERAGE AND PLACEMENT RYAN MYERS, Operational Excellence Manager at PinnacleART BRIAN MARINO, Engineering Specialist at PinnacleART

More information

Brazed aluminium heat exchangers (BAHXs), also referred to

Brazed aluminium heat exchangers (BAHXs), also referred to Brazed aluminium heat exchangers (BAHXs), also referred to as plate fin heat exchangers, are at the heart of many of the processes used for the liquefaction of natural gas. They are deployed across the

More information

Overview. Challenges in Opportunity Crude Processing 16 th April 2012

Overview. Challenges in Opportunity Crude Processing 16 th April 2012 1 Challenges in Opportunity Crude Processing 16 th April 2012 Thomas Lu Industry Development Manager Asia Pacific Overview Opportunity Crude Trends (High TAN Crude) and its challenges Overview of Factors

More information

Available online at ScienceDirect. Procedia Engineering 86 (2014 )

Available online at  ScienceDirect. Procedia Engineering 86 (2014 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 86 (2014 ) 597 605 1st International Conference on Structural Integrity, ICONS-2014 Corrosion Risk Analysis, Risk Based Inspection

More information

Detection of In-service Wet H 2 S Cracking at Reboiler Shell Weldment using Phased Array Ultrasonic Testing (PAUT)

Detection of In-service Wet H 2 S Cracking at Reboiler Shell Weldment using Phased Array Ultrasonic Testing (PAUT) More Info at Open Access Database www.ndt.net/?id=15158 Detection of In-service Wet H 2 S Cracking at Reboiler Shell Weldment using Phased Array Ultrasonic Testing (PAUT) Gautam Das 1, D. Dutta 2, Kaushik

More information

Best Practice Corrosion/Erosion Monitoring and Critical Process Indicators Salton Sea KGRA. by Dr. Dan Hoyer, PE Veizades & Associates, Inc.

Best Practice Corrosion/Erosion Monitoring and Critical Process Indicators Salton Sea KGRA. by Dr. Dan Hoyer, PE Veizades & Associates, Inc. 1 Best Practice Corrosion/Erosion Monitoring and Critical Process Indicators Salton Sea KGRA by Dr. Dan Hoyer, PE Veizades & Associates, Inc. Outline Process Indicators Challenges in High Temperature Corrosion

More information

TUBE INSPECTION SOLUTIONS TUBE INSPECTION SOLUTIONS. Selection of heat exchanger tube inspection techniques

TUBE INSPECTION SOLUTIONS TUBE INSPECTION SOLUTIONS. Selection of heat exchanger tube inspection techniques TUBE INSPECTION SOLUTIONS 1 TUBE INSPECTION SOLUTIONS Selection of heat exchanger tube inspection techniques 2 TUBE INSPECTION SOLUTIONS THIS PERSONAL WORKBOOK BELONGS TO First name Lastname Address City

More information

AVOID COSTLY MEASURES

AVOID COSTLY MEASURES A MISTRAS GROUP BRAND AVOID COSTLY MEASURES REMOTE THICKNESS TRACKING AUTOMATED ULTRASONIC THICKNESS DATA ANALYSIS SYSTEM OVERVIEW AUTOMATED ULTRASONIC THICKNESS DATA ANALYSIS COMPATIBILITY SEAMLESS INTEGRATION

More information

SmartCET Corrosion Monitoring On-line, Real time Product Information Note

SmartCET Corrosion Monitoring On-line, Real time Product Information Note SmartCET Corrosion Monitoring On-line, Real time Product Information Note Live corrosion monitoring brings Corrosion Management to life. SmartCET technology is the only system of its kind, enabling operators

More information

Weld Root Measurement by ToFD for Inspection of Flow-Accelerated Corrosion Susceptible Welds

Weld Root Measurement by ToFD for Inspection of Flow-Accelerated Corrosion Susceptible Welds 18 th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Weld Root Measurement by ToFD for Inspection of Flow-Accelerated Corrosion Susceptible Welds Damien DELACOUX, Stephane

More information

mott corporation Process Systems Safe, reliable, fully automated catalyst recovery. The Mott solution.

mott corporation Process Systems Safe, reliable, fully automated catalyst recovery. The Mott solution. mott corporation Process Systems Safe, reliable, fully automated catalyst recovery. The Mott solution. Maximizing catalyst retention. Introduction. Process operations involving catalysts have traditionally

More information

High Temperature Ultrasonic Scanning

High Temperature Ultrasonic Scanning ABSTRACT High Temperature Ultrasonic Scanning R. J. Carswell Saudi Aramco Dhahran, Saudi Arabia Corrosion is one of the Petrochemical Industry s leading causes of equipment failure, repair, and replacement.

More information

Utilizing NDT for Cost Effective Maintenance and Mitigation Purposes

Utilizing NDT for Cost Effective Maintenance and Mitigation Purposes Utilizing NDT for Cost Effective Maintenance and Mitigation Purposes W. L. Ying and A. Sadri Hatch Ltd., 2800 Speakman Drive, Mississauga, Ontario, Canada. E-mail: winnie.ying@hatch.com More info about

More information

AVOID COSTLY MEASURES

AVOID COSTLY MEASURES A MISTRAS GROUP BRAND AVOID COSTLY MEASURES REMOTE THICKNESS TRACKING AUTOMATED ULTRASONIC THICKNESS DATA ANALYSIS SYSTEM OVERVIEW AUTOMATED ULTRASONIC THICKNESS DATA ANALYSIS COMPATIBILITY SEAMLESS INTEGRATION

More information

Prevention solution for corrosion issues in CO2 removal units in ammonia plants

Prevention solution for corrosion issues in CO2 removal units in ammonia plants Prevention solution for corrosion issues in CO2 removal units in ammonia plants Case Study Report Doc. No: AKH01-STD-ENG-RPT-001 Contents 1. Introduction... 2 2. Background... 2 3. Conclusion... 4 4. Lessons

More information

PREVENTING FLANGE FACE CORROSION. In seawater and hydrocarbon services. A CORRICULITE SEALED.INsight.

PREVENTING FLANGE FACE CORROSION. In seawater and hydrocarbon services. A CORRICULITE SEALED.INsight. PREVENTING FLANGE FACE CORROSION In seawater and hydrocarbon services. A CORRICULITE SEALED.INsight. 01. CONTENTS p03 p04 p06 p07 p09 01. Introduction 02. Corrosion Mechanisms 03. Current Market Landscape

More information

specific amine large changes Environmental to acid

specific amine large changes Environmental to acid O OPTIMIZING REFINE RY AMINE SYSTEM PERFORMANCE WITHOUT CAPITAL Why U.S. Refineries have turned to MDEA formulations for clean diesel related expansions and increased sulfur crude slates. Erik Stewart,

More information

Taravosh Jam Design & Engineering Co.

Taravosh Jam Design & Engineering Co. Taravosh Jam Design & Engineering Co. Taravosh Jam co. as an Iranian EPC contractor supplies following refinery equipment and facilities based on the know-how and to international standards. 1- The Main

More information

Corrosion Potential - Refinery Overhead Systems

Corrosion Potential - Refinery Overhead Systems Corrosion Potential - Refinery Overhead Systems Amit Patel Bartlesville, Oklahoma OLI Simulation Conference November 16-18, 2010 Whippany, NJ Corrosivity Amine Hydrochlorides Impact of overhead corrosion

More information

Phoenix Temperature Measurement. Surface Engineering and Heat Treatment Industry Conference. 16 October 2015 Stratford-upon-Avon

Phoenix Temperature Measurement. Surface Engineering and Heat Treatment Industry Conference. 16 October 2015 Stratford-upon-Avon Surface Engineering and Heat Treatment Industry Conference 16 October 2015 Stratford-upon-Avon Challenges and Benefits of Temperature Profiling in the Heat Treatment Industry Dave Plester, Director PhoenixTM

More information

Nathan A. Hatcher and Ralph H. Weiland, Optimized Gas Treating Inc., USA, discuss the fate of ammonia in refinery amine systems.

Nathan A. Hatcher and Ralph H. Weiland, Optimized Gas Treating Inc., USA, discuss the fate of ammonia in refinery amine systems. Special treatment T he corrosion that results from ammonia ingress and accumulation in refinery and biogas amine systems is a problem that may be exacerbated by the increasing utilisation of advantaged

More information

Steam Generator Management (QA)

Steam Generator Management (QA) Steam Generator Management (QA) Program Description Program Overview Many factors affect materials degradation in steam generators, including water chemistry, inspection limitations, material performance

More information

Detecting metal loss and pipeline wall thinning with a combination of Ultrasonic Testing (UT) and Magnetic Flux Leakage (MFL)

Detecting metal loss and pipeline wall thinning with a combination of Ultrasonic Testing (UT) and Magnetic Flux Leakage (MFL) Detecting metal loss and pipeline wall thinning with a combination of Ultrasonic Testing (UT) and Magnetic Flux Leakage (MFL) Wolfgang Krieg ROSEN Swiss AG Abstract In-line inspections with Ultrasonic

More information

Downsizing a Claus Sulfur Recovery Unit

Downsizing a Claus Sulfur Recovery Unit INFRASTRUCTURE MINING & METALS NUCLEAR, SECURITY & ENVIRONMENTAL Downsizing a Claus Sulfur Recovery Unit OIL, GAS & CHEMICALS By Charles L. Kimtantas and Martin A. Taylor ckimtant@bechtel.com & mataylo1@bechtel.com

More information

Sulfur Unit Equipment Problems and Low Silicon Carbon Steel Corrosion Gerald W. Wilks Lemont Refinery CITGO Petroleum

Sulfur Unit Equipment Problems and Low Silicon Carbon Steel Corrosion Gerald W. Wilks Lemont Refinery CITGO Petroleum Sulfur Unit Equipment Problems and Low Silicon Carbon Steel Corrosion Gerald W. Wilks Lemont Refinery CITGO Petroleum 2010 CITGO Petroleum Corporation. Summary Weld cracking in piping connecting a reaction

More information

Chevron North Sea Limited (CNSL) operates more than 25 pipelines across three operated assets in the UK North Sea: Alba, Captain and Erskine.

Chevron North Sea Limited (CNSL) operates more than 25 pipelines across three operated assets in the UK North Sea: Alba, Captain and Erskine. EFFECTIVE USE OF IN-LINE INSPECTION TECHNOLOGIES TO SUPPORT PIPELINE INTEGRITY MANAGEMENT By Peter Smith, Chevron North Sea Limited and Andrew Wilde, MACAW Engineering Ltd, UK Abstract Chevron North Sea

More information

Specialist Services for Energy Infrastructure

Specialist Services for Energy Infrastructure Specialist Services for Energy Infrastructure Company Profile From its bases across the UK and its international hubs, Glacier Energy Services provides products, services and engineered solutions in the

More information

Claus plants. SURE oxygen enrichment portfolio for sulfur recovery in

Claus plants. SURE oxygen enrichment portfolio for sulfur recovery in Refining SURE oxygen enrichment portfolio for sulfur recovery in Claus plants. Covering the full oxygen enrichment range for increased capacity, flexibility and reliability. APPLICATION TECHNOLOGIES O₂

More information

Ensuring Compliance and Integrity

Ensuring Compliance and Integrity Ensuring Compliance and Integrity with Asset Performance Management bhge.com/digital Ensuring Compliance and Integrity with Asset Performance Management Overview The role of asset integrity management

More information

Asset Integrity Solutions. All-of-facility care for complete field life

Asset Integrity Solutions. All-of-facility care for complete field life Asset Integrity Solutions All-of-facility care for complete field life Who we are Wood Group is an international energy services company with an established track-record in delivering powerful solutions

More information

The naphtha hydrotreater

The naphtha hydrotreater Mitigation of heat exchanger fouling Detailed analysis of potential contributors identifies the root cause of fouling in naphtha hydrotreater feed-effluent exchangers BRUCE WRIGHT Baker Hughes Incorporated

More information

Brochure. Aspen PIMS

Brochure. Aspen PIMS Brochure Aspen PIMS Since 1984, Aspen PIMS has facilitated better feedstock selection, business risk management and downtime planning to optimize profitability. Today, the Aspen PIMS family offers the

More information

Distillation Debottlenecking & Optimisation A Eurotek training course

Distillation Debottlenecking & Optimisation A Eurotek training course Distillation Debottlenecking & Optimisation A Eurotek training course ERS Distillation Debottlenecking & Optimisation An introduction: Refining of crude oil and the recovery of saleable products from the

More information

Seal-less Pump Technology. Oil and Gas. Robust design - Reliability

Seal-less Pump Technology. Oil and Gas. Robust design - Reliability Seal-less Pump Technology Oil and Gas Robust design - Reliability Hydra-Cell Oil and Gas Industry Pumps Compact seal-less pumps for long life and high reliability Gas Drying Pumping hot TEG With over 35

More information

Guidelines for Avoiding Sulfidation (Sulfidic) Corrosion Failures in Oil Refineries

Guidelines for Avoiding Sulfidation (Sulfidic) Corrosion Failures in Oil Refineries http://www.booksfiles.org/637-api-rp-939-c.html Guidelines for Avoiding Sulfidation (Sulfidic) Corrosion Failures in Oil Refineries Downstream Segment API RECOMMENDED PRACTICE 939-C FIRST EDITION, MAY

More information

Reactor internals - optimizing catalyst performance

Reactor internals - optimizing catalyst performance Reactor internals - optimizing catalyst performance Cross-section of a hydroprocessing reactor Inlet diffuser Reduces the energy of the two-phase mixture before it reaches the distribution tray. Scale

More information

Predict 7.1 Product Information Note

Predict 7.1 Product Information Note Connected Plant Predict 7.1 Product Information Note Accurate Corrosion Prediction for Carbon Steel in Multiphase Oil & Gas Production or Transmission Systems: Predict 7.1 is the latest update to the industry-leading

More information

Review of Cathodic Protection Systems for Concrete Structures in Australia Lessons Learnt and Future Directions

Review of Cathodic Protection Systems for Concrete Structures in Australia Lessons Learnt and Future Directions Review of Cathodic Protection Systems for Concrete Structures in Australia Lessons Learnt and Future Directions A. Cheaitani Remedial Technology Pty Ltd, Sydney, Australia SUMMARY: Impressed current cathodic

More information

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT

MID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT SMART THINKING WATER ULTRIMIS W ULTRASONIC WATER METER DN15, DN20, D25 i DN32 MID R 800 AMR READY Ultrimis W a state-of-the-art ultrasonic water meter with the very latest patented design features including

More information

PRESSURE WAVE ANALYSIS STREAMLINES PIPELINE PIGGING. Thomas Redares and Neil Stewart, Halliburton Pipeline & Process Services

PRESSURE WAVE ANALYSIS STREAMLINES PIPELINE PIGGING. Thomas Redares and Neil Stewart, Halliburton Pipeline & Process Services PRESSURE WAVE ANALYSIS STREAMLINES PIPELINE PIGGING Thomas Redares and Neil Stewart, Halliburton Pipeline & Process Services 1. Introduction Pipelines are used in many industries to transport a wide variety

More information

Reformer and Heater Tubes Temperature Accuracy Comparing Practical Infrared Techniques

Reformer and Heater Tubes Temperature Accuracy Comparing Practical Infrared Techniques Reformer and Heater Tubes Temperature Accuracy Comparing Practical Infrared Techniques Sonny James, Level III Certified Infrared Thermographer ASNT NDT Level III IR, MT, PT, UT & RT Certified Welding Inspector

More information

A Wireless, Multi-Parameter Method and Device for Monitoring the Condition of Pipelines and Mechanical Structures

A Wireless, Multi-Parameter Method and Device for Monitoring the Condition of Pipelines and Mechanical Structures A Wireless, Multi-Parameter Method and Device for Monitoring the Condition of Pipelines and Mechanical Structures Eugene B. Silverman, PhD Berkeley Springs Instruments 14901 Uhl Hwy, SE Cumberland, Maryland

More information

CUSTOMER SERVICES YOUR PARTNERSHIP WITH THE WORLD LEADER IN INDUSTRIAL GASES

CUSTOMER SERVICES YOUR PARTNERSHIP WITH THE WORLD LEADER IN INDUSTRIAL GASES CUSTOMER SERVICES YOUR PARTNERSHIP WITH THE WORLD LEADER IN INDUSTRIAL GASES Air Liquide Group Air Liquide Engineering & Construction The world leader in gases, technologies and services for Industry and

More information

Automated ultrasonic tube-to-tube sheet weld scanning

Automated ultrasonic tube-to-tube sheet weld scanning White Paper Automated ultrasonic tube-to-tube sheet weld scanning By: J. Peter Bertelsen & Zdravko Kishev, Advanced NDT Global Abstract This paper describes an advantageous ultrasonic technique for in-depth

More information

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer Reducing FCC Turnaround Costs Focus on Speed & Safety Brent Dell Sr. Technical Engineer 1 Agenda Brief company introduction Preparing FCC for entry; keys to success Pre-T/A planning FCC Case Study Conclusion

More information

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer Reducing FCC Turnaround Costs Focus on Speed & Safety Brent Dell Sr. Technical Engineer 1 Agenda Brief company introduction Preparing FCC for entry; keys to success Pre-T/A planning FCC Case Study Conclusion

More information

In-Line Inspection using Ultrasonic Technology

In-Line Inspection using Ultrasonic Technology In-Line Inspection using Ultrasonic Technology Dr. Thomas Hennig NDT Global GmbH & Co KG Friedrich List Str. 1 76297 Stutensee Germany Jason Chan NDT Global Tampines Industrial Park A Tampines Street 93

More information

Machining, Bolting and Flange Management

Machining, Bolting and Flange Management Machining, Bolting and Flange Management www.storktechnicalservices.com 02 03 04 05 08 09 10 11 introduction overview machining & bolting hot bolt replacement pipe cutting in-situ machining IBOLT FLANGE

More information

Monitoring Asset Integrity Using Installed Ultrasonic Sensors

Monitoring Asset Integrity Using Installed Ultrasonic Sensors Monitoring Asset Integrity Using Installed Ultrasonic Sensors May 25, 2016 Sensor Networks, Inc. Steve Strachan V.P. Sales North America Outline Motivation Inspection vs. monitoring/trending Power of Data

More information

Pulsed Eddy Current Testing (PECT) Inspection Technique

Pulsed Eddy Current Testing (PECT) Inspection Technique Introduction Pulsed Eddy Current Testing (PECT) is an inspection technique used for corrosion under insulation (CUI) screening on carbon steel structures as pipes, vessels, tanks and spherical tank legs

More information

COKE-OVEN GAS PROCESSING EQUIPMENT

COKE-OVEN GAS PROCESSING EQUIPMENT COKE-OVEN GAS PROCESSING EQUIPMENT CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF APPARATUSES... 4 2.1 Primary Cooler...4 2.2 Final Cooler...5 2.3 Tar Sludge Rough Separator...5 2.4 Tar Condensate Separator...6

More information

Corrosion Under Insulation (CUI) inspection of cold insulated lines

Corrosion Under Insulation (CUI) inspection of cold insulated lines Corrosion Under Insulation (CUI) inspection of cold insulated lines Savio REBELLO, Paresh GOSWAMI More info about this article: http://www.ndt.net/?id=22333 Abstract Reliance Industries Limited, Reliance

More information

Easy ways to boost. your productivity.

Easy ways to boost. your productivity. Refining Easy ways to boost your productivity. Fine-tuning key links in your process flow can give you the tools to optimise capacity, reliability and flexibility for a healthier bottom line. APPLICATION

More information

INTRODUCTION TO ULTRASONIC IN-LINE INSPECTION OF CRA PIPELINES. Herbert Willems, Gerhard Kopp NDT Global, Germany

INTRODUCTION TO ULTRASONIC IN-LINE INSPECTION OF CRA PIPELINES. Herbert Willems, Gerhard Kopp NDT Global, Germany INTRODUCTION TO ULTRASONIC IN-LINE INSPECTION OF CRA PIPELINES Herbert Willems, Gerhard Kopp NDT Global, Germany ABSTRACT Pipelines manufactured from corrosion-resistant alloys (CRA) are becoming more

More information

Salt deposition in FCC gas concentration

Salt deposition in FCC gas concentration Salt Deposition in FCC Gas Concentration Units Michel Melin Director Technical Service Grace Davison Refining Technologies Europe, Middle East and Africa Colin Baillie Marketing Manager Grace Davison Refining

More information

APC Corrosion & Thickness Monitoring Solution

APC Corrosion & Thickness Monitoring Solution APC Corrosion & Thickness Monitoring Solution with A 3 M spoton U Permanently-installed real-time internal corrosion and erosion monitoring solution designed to operate in most environments and locations.

More information

DEVELOPMENT OF A LOW DRIFT TYPE K THERMOCOUPLE CABLE FOR AEROSPACE APPLICATIONS

DEVELOPMENT OF A LOW DRIFT TYPE K THERMOCOUPLE CABLE FOR AEROSPACE APPLICATIONS DEVELOPMENT OF A LOW DRIFT TYPE K THERMOCOUPLE CABLE FOR AEROSPACE APPLICATIONS Dr Michele Scervini Research Scientist University of Cambridge Trevor D Ford Technical Director CCPI Europe Limited ABSTRACT

More information

Heat Treatment of Tubes for Condenser, Feedwater Heater, and Shell & Tube Heat Exchangers

Heat Treatment of Tubes for Condenser, Feedwater Heater, and Shell & Tube Heat Exchangers Heat Treatment of Tubes for Condenser, Feedwater Heater, and Shell & Tube Heat Exchangers 1. SCOPE 1.1 The purpose of this document is to provide an overview of the different types of heat treatment processes

More information

Bolt-On Thermal Maintenance System in new SRU challenges old design rules

Bolt-On Thermal Maintenance System in new SRU challenges old design rules Bolt-On Thermal Maintenance System in new SRU challenges old design rules R. ZUNTI Projex Technologies Ltd Suite 2100, 444-5th Avenue SW, Calgary, AB T2P 2T8, Canada R. SIMMS Shell Canada Ltd 400-4 Avenue

More information

PRESSURE VESSELS Part III: Design Loads, Wind & Seismic, Skirts, Legs, Saddles, Nonstandard

PRESSURE VESSELS Part III: Design Loads, Wind & Seismic, Skirts, Legs, Saddles, Nonstandard PRESSURE VESSELS Part III: Design Loads, Wind & Seismic, Skirts, Legs, Saddles, Nonstandard Flanges. STUDY NOTES Instructor: Javier Tirenti Index Introduction... 4 1. Material selection... 8 1.1) Corrosion...

More information

COMBIMASS Thermal Gas Flow

COMBIMASS Thermal Gas Flow COMBIMASS Thermal Gas Flow The COMBIMASS series enables gas flow measurement for various applications in all industry sectors. COMBIMASS works according to the principle of thermal dispersion and determines

More information

Inspection Qualification II

Inspection Qualification II Inspection Qualification II Qualification According to ENIQ of Complete EPR RPV Inspection Using Phased Array F. Mohr, G. Guse, intelligendt System & Services, Germany INTRODUCTION On each new reactor

More information

Optimizing a World-Scale Petrochemical Plant

Optimizing a World-Scale Petrochemical Plant Optimizing a World-Scale Petrochemical Plant Uberne A. Tapia 2012 Business Optimization Conference Kuala Lumpur, Malaysia Agenda The need for Optimization RPMS Project Implementation Methodology RPMS Solution

More information

DCU Process Control. Protecting Critical Investments & Optimizing Process Control with Advanced Temperature Measurement Systems

DCU Process Control. Protecting Critical Investments & Optimizing Process Control with Advanced Temperature Measurement Systems DCU Process Control Protecting Critical Investments & Optimizing Process Control with Advanced Temperature Measurement Systems Presented By: Taylor Fama Regional Technology Manager 1 AGENDA I. Intro to

More information

Removal of Heat Stable Salts A Solution to Amine Plant Operational Problems

Removal of Heat Stable Salts A Solution to Amine Plant Operational Problems Removal of Heat Stable Salts A Solution to Amine Plant Operational Problems Chemical Engineering in Petroleum & Natural Gas Journal, China, December 2002 J. Shao, Technical Marketing Specialist, Eco-Tec

More information

/ Hybrid Cooling Towers

/ Hybrid Cooling Towers / Hybrid Cooling Towers Cooling Towers without visible plume / Cooling Technologies Balcke Hamon Dry Cooling Marley / Visible plume an avoidable problem / Every wet cooling tower generates a visible plume

More information