Thermometry, Spain, CEM (Centro Español de Metrologia), INTA (Instituto Nacional de Técnica Aeroespacial)
|
|
- Willa Bailey
- 6 years ago
- Views:
Transcription
1 Calibration and Capabilities Thermometry, Spain, (Centro Españ de Metrogia), INTA (Instituto Nacional de Técnica Aeroespacial) Calibration or s Measurand Level ange a relative NMI NMI Argon point for SPRT ºC (23 ± 1) ºC 1.3 mk 2 95% No 18 1 Indium point ºC (23 ± 1) ºC 1.1 mk 2 95% No 18 5 Tin point ºC (23 ± 1) ºC 0.9 mk 2 95% No 18 6 Aluminium point ºC (23 ± 1) ºC 4.0 mk 2 95% No 18 8 triple point of Mercury ºC (23 ± 1) ºC 0.5 mk 2 95% No Zinc ºC (23 ± 1) ºC 2.0 mk 2 95% No and HT SPRT Aluminium ºC (23 ± 1) ºC 9.0 mk 2 95% No Long stem HT SPRT Silver ºC (23 ± 1) ºC 18 mk 2 95% No Radiation Copper ºC Wavelengh 650 nm and 950 nm 1 to 4 K 2 95% No (23 ± 1) ºC < 60 % -75 < -70 ºC (23 ± 1) ºC 0.15 ºC 2 95% No 50 INTA -70 < -60 ºC 51 INTA -60 < -10 ºC (23 ± 1) ºC 0.05 ºC 2 95% No 52 INTA The BIPM key comparison database, July /4
2 Calibration and Capabilities Thermometry, Spain, (Centro Españ de Metrogia), INTA (Instituto Nacional de Técnica Aeroespacial) Calibration or s Measurand Level ange a relative NMI NMI ºC Test chamber 0 C to 100 C 0.05 ºC 2 95% No 53 INTA > ºC Test chamber 0 C to 100 C 0.10 ºC 2 95% No 54 INTA > ºC Test chamber 0 C to 100 C 0.15 ºC 2 95% No 55 INTA 0 95 ºC Continuous gas flow maximum 5 l/min 0.05 ºC 2 95% No 61 INTA Atmospheric pressure (1000 ± 50) hpa (23 ± 1) ºC Platinum Resistance Thermometers Comparison ºC Liquid bath alcoh bath 0.02 ºC 2 95% No 28 Platinum Resistance Thermometers Comparison 0 90 ºC Liquid bath water bath 0.01 ºC 2 95% No 29 Platinum Resistance Thermometers Comparison ºC Liquid bath oil bath 0.02 ºC 2 95% No 30 S Tin point ºC (23 ± 1) ºC 0.21 ºC 2 95% No 31 S Zinc point ºC (23 ± 1) ºC 0.20 ºC 2 95% No 32 S Aluminium point ºC (23 ± 1) ºC 0.22 ºC 2 95% No 33 S Silver point ºC (23 ± 1) ºC 0.25 ºC 2 95% No 34 S Copper point ºC (23 ± 1) ºC 0.34 ºC 2 95% No 35 The BIPM key comparison database, July /4
3 Calibration and Capabilities Thermometry, Spain, (Centro Españ de Metrogia), INTA (Instituto Nacional de Técnica Aeroespacial) Calibration or s Measurand Level ange a relative NMI NMI S S Tin point ºC Zinc point ºC Aluminium point ºC Silver point ºC Copper point ºC Tin point ºC Zinc point ºC Aluminium point ºC Silver point ºC ºC ºC (23 ± 1) ºC 0.28 ºC 2 95% No (23 ± 1) ºC 0.21 ºC 2 95% No (23 ± 1) ºC 0.14 ºC 2 95% No (23 ± 1) ºC 0.19 ºC 2 95% No (23 ± 1) ºC 0.16 ºC 2 95% No (23 ± 1) ºC 0.12 ºC 2 95% No (23 ± 1) ºC 0.40 ºC 2 95% No (23 ± 1) ºC 0.41 ºC 2 95% No b 37b 38b 39b or ºC (23 ± 1) ºC 0.21 ºC 2 95% No ºC ºC (23 ± 1) ºC 0.24 ºC 2 95% No (23 ± 1) ºC 0.16 ºC 2 95% No Comparison ºC Liquid bath alcoh bath 0.06 ºC 2 95% No 44 44b 45 The BIPM key comparison database, July /4
4 Calibration and Capabilities Thermometry, Spain, (Centro Españ de Metrogia), INTA (Instituto Nacional de Técnica Aeroespacial) Calibration or s Measurand Level ange a relative NMI NMI Sensors with Display Unit Sensors with Display Unit Sensors with Display Unit Comparison ºC Liquid bath alcoh bath 0.02 ºC 2 95% No Comparison 0 90 ºC Liquid bath water bath 0.01 ºC 2 95% No Comparison ºC Liquid bath oil bath 0.02 ºC 2 95% No Comparison ºC Liquid bath oil bath 0.04 ºC 2 95% No Comparison ºC Liquid bath alcoh bath 0.02 ºC 2 95% No Comparison 0 90 ºC Liquid bath water bath 0.01 ºC 2 95% No Comparison ºC Liquid bath oil bath 0.02 ºC 2 95% No Water triple point Direct comparison ºC (23 ± 1) ºC 0.12 mk 2 95% No 20 January Calibration at water triple point ºC (23 ± 1) ºC 0.5 mk 2 95% No 20 January triple point of Argon ºC (23 ± 1) ºC 1.5 mk 2 95% No melting point of Gallium ºC (23 ± 1) ºC 0.5 mk 2 95% No Indium ºC (23 ± 1) ºC 1.3 mk 2 95% No Tin ºC (23 ± 1) ºC 1.3 mk 2 95% No The BIPM key comparison database, July /4
5 Calibration and Capabilities, Gases, Spain (Centro Españ de Metrogia), ISCIII (Instituto de Salud Carlos III) The range is expressed as the of the smallest of the quantity to the of the largest of the quantity. The uncertainties correspond to k = 2 (level of confidence 95%) NMI (a) (a) (a) (b) (b) (a) (a) (b) 6.6-4A(b) 6.6-7G (2) Measure ment Sub- Category Fuel Matrix synthetic natural gas Analyte or Component methane oxygen oxygen methane ethane Measurand From To Unit From To Unit Dissemination Range of Capability µ/m µ/m m/ µ/m µ/m µ/m m/ m/ m/ m/ µ/m m/ m/ Range of Expanded Uncertainties as Disseminated % Yes % Yes % Yes % Yes % Yes % Yes % Yes % Yes % Yes % Yes % Yes From To Unit From To Unit µ/m m/ µ/m µ/m µ/m m/ m/ m/ m/ µ/m % Yes % Yes % Yes % Yes % Yes % Yes % Yes % Yes % Yes % Yes Calibration, CRM, (a) PRM supply and analyser CRM supply and analyser CRM supply and analyser CRM supply and analyser CRM supply and analyser % Yes Calibration % Yes Range of Certified Values in Reference Materials Range of Expanded Uncertainties for Certified Value Mechanism(s) for Delivery 01 March March March July July March March March July 2007 provider The BIPM key comparison database, August /2
6 Calibration and Capabilities, Gases, Spain (Centro Españ de Metrogia), ISCIII (Instituto de Salud Carlos III) The range is expressed as the of the smallest of the quantity to the of the largest of the quantity. The uncertainties correspond to k = 2 (level of confidence 95%) NMI 6.6-4A(a) Measure ment Sub- Category Matrix Measurand Analyte or Component i-butane n-butane Dissemination Range of Capability Range of Expanded Uncertainties as Disseminated From To Unit From To Unit m/ m/ m/ m/ m/ m/ m/ % Yes % Yes % Yes % Yes % Yes Range of Certified Values in Reference Materials % Yes % Yes Range of Expanded Uncertainties for Certified Value From To Unit From To Unit m/ m/ % Yes % Mechanism(s) for Delivery Calibration, PRM (6.6-4A(PRM)) and CRM (6.6-4A(CRM)) 15 December 2008 provider m/ % Yes m/ % oxygen m/ % Yes m/ % ISCIII/01 purified air ozone n/m Q[1.1, x (O 3 )] n/m No Calibration of monitors and ozone generation 19 July 2010 ISCIII The BIPM key comparison database, August /2
Thermometry, Chinese TAIPEI, CMS (Center for Measurement Standards)
Mercury triple point -38.8344-38.8344 C Thermostat 0.54 mk 2 95% No Approved on 28 June 2007 Comparison with reference (s) 0.01 0.01 C 0.08 mk 2 95% No 0.01 0.01 C 0.09 mk 2 95% No Gallium melting point
More informationThermometry laboratory
NATIONAL INSTITUTE OF METROLOGY Thermometry laboratory Bucharest, ROMANIA Sonia Gaiţă soniagaita@hotmail.com Historical background The Thermometry Laboratory in INM was set up in 1951: various cell models
More informationPrice List. Calibration Fee
Thermometry Metrology Calibration Fee 1 Fixed point cells - 38.8344 C 0.5 mk 25,000/point Comparison against NIMT's Fixed 11010-11111 (Primary and Secondary fixed points) 0.01 C 0.2 mk Points 29.7646 C
More informationRealization of ITS-90 from K through K: One Company s Approach
Realization of ITS-90 from 273.15 K through 1234.93 K: One Company s Approach Xumo Li, Steve Iman, Mike Hirst, Mingjian Zhao Hart Scientific, Inc. Abstract All of the fixed points of the International
More informationIMPROVEMENTS RELATING TO THE CALIBRATION OF THERMOMETERS
IMPROVEMENTS RELATING TO THE CALIBRATION OF THERMOMETERS Abstract: ITS-90 specifies a series of temperatures which are used to define the scale. Supplementary Information to ITS-90 describes how these
More informationPrimary Standards for Temperature Calibration
Primary Standards for Temperature Calibration Standards Platinum Resistance Thermometers and Standards Thermocouples SPRTs Model R TPW Range 5681 25.5Ω 200 C to 661 C 670 (DB1/30) 5683 25.5Ω 200 C to 480
More informationA Study on the Stability of Standard Platinum Resistance Thermometer in the Temperature Range from 0 C through 720 C
A Study on the Stability of Standard Platinum Resistance Thermometer in the Temperature Range from 0 C through 720 C Speaker: Xumo Li Hart Scientific, Inc. 799 East Utah Valley Drive, American Fork, UT
More informationACCREDITED CALIBRATION LABORATORY SERVICE AS A SUBJECT OF AN INTEGRAL QA SYSTEM AT EARS
ACCREDITED CALIBRATION LABORATORY SERVICE AS A SUBJECT OF AN INTEGRAL QA SYSTEM AT EARS D.Groselj, S.Žlebir, J.Knez Environmental Agency of the Republic of Slovenia Vojkova 1b, 1000 Ljubljana, Slovenia
More informationREALIZATION OF THE FREEZING POINTS OF INDIUM, TIN AND ZINC USING STAINLESS STEEL CASED CELLS
REALIZATION OF THE FREEZING POINTS OF INDIUM, TIN AND ZINC USING STAINLESS STEEL CASED CELLS Xumo Li, Mingjian Zhao and Deming Chen Hart Scientific ABSTRACT Realization of the freezing points of indium,
More informationExperimental Study and Computer Modeling of the Triple Point of Argon System
Experimental Study and Computer Modeling of the Triple Point of Argon System Speaker: Rong Ding Fluke Calibration 799 East Utah Valley Drive American Fork, Utah 84003-9775, USA E-mail: rong.ding@fluke.com
More informationExperimental Study and Computer Modeling of the Triple Point of Argon System
Experimental Study and Computer Modeling of the Triple Point of Argon System R. Ding, M. J. Zhao, T. Nielson, E. Nerdrum, and D. Farley Abstract: The triple point of argon is a defined fixed point in ITS-90
More informationNew Type of Precision Thermometer Offers Unrivalled Accuracy and Stability
Integrity in Temperature Calibration New Type of Precision Thermometer Offers Unrivalled Accuracy and Stability Isothermal Technology Limited (Isotech) has introduced a new type of precision thermometer,
More informationSLIM QUARTZ & METAL CLAD CELLS User Maintenance Manual/Handbook
SLIM QUARTZ & METAL CLAD CELLS User Maintenance Manual/Handbook Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704 544799 Internet: www.isotech.co.uk
More informationüthe Source for Calibration Professionals Solutions for Primary & Secondary Laboratories Temperature Calibration Equipment & Services
1 üthe Source for Calibration Professionals Solutions for Primary & Secondary Laboratories Temperature Calibration Equipment & Services Copper Freeze Point Cells 1084.62ºC COPPER FREEZES - Required calibration
More informationA High-Quality Platinum Resistance Thermometer to 661 C
A High-Quality Platinum Resistance Thermometer to 661 C Presenter: Mingjian Zhao 799 East Utah Valley Drive American Fork, UT 843-9775 Phone: (81) 763-16 Fax: (81) 763-11 E-mail: mingjian_zhao@hartscientific.com
More informationRaad voor Accreditatie (Dutch Accreditation Council RvA) Accreditation of Reference Material Producers
Raad voor Accreditatie (Dutch Accreditation Council RvA) Accreditation of Reference Material Producers Document code: RvA-T034-UK Version 4, 01 mei 2013 A RvA-Explanatory note describes the policy and/or
More informationReport on NIM-NMC Bilateral Comparison: SPRT Calibration. Comparison from -190 o C to 420 o C
Report on NIM-NMC Bilateral Comparison: SPRT Calibration Comparison from -190 o C to 420 o C CCT-K3.2 Prepared by Sun Jianping National Institute of Metrology, China 1 Introduction Several international
More informationCCT WG8 CMC REVIEW PROTOCOLS: DEVELOPMENT AND IMPLEMENTATION
CCT WG8 CMC REVIEW PROTOCOLS: DEVELOPMENT AND IMPLEMENTATION Gregory Strouse Mark Ballico Jovan Bojkovski Hans Liedberg Anatoly Pokhodun Martin de Groot National Institute of Standards and Technology Gaithersburg,
More informationPresented By: Matt Sica
FQS Accreditation for forensic testing agencies Presented By: Matt Sica ANSI-ASQ National Accreditation Board Implies an unbroken path to a higher level of accuracy or authority. Characterized by a number
More informationTemperature calibration
Temperature calibration Temperature calibration refers to the calibration of any device used in a system that measures temperature. Most importantly, this usually means the temperature sensor, itself,
More informationLab #1a Temperature Measurement
Lab #1a Temperature Measurement Goals of lab Outline Purposes of measuring temperature Temperature scales Temperature standards Time constant Conventional temperature measuring devices Liquid-in-glass
More informationA TECHNICAL GUIDE AND STANDARD FOR THE USE OF GALLIUM MELT-POINT CELLS
A TECHNICAL GUIDE AND STANDARD FOR THE USE OF GALLIUM MELT-POINT CELLS Henry E. Sostmann RATIONALE In the last issue of the Isotech Journal of Thermometry (Vol. 3 No. 2, 1992) we published a Technical
More informationüthe Source for Calibration Professionals Solutions for Primary & Secondary Laboratories Temperature Calibration Equipment & Services
1 üthe Source for Calibration Professionals Solutions for Primary & Secondary Laboratories Temperature Calibration Equipment & Services Isotech Catalogues... Temperature Calibration Equipment and Services
More informationReference thermometer Model CTP5000
Calibration technology Reference thermometer Model CTP5000 WIKA data sheet CT 61.20 Applications Reference thermometer for measuring very accurate temperature in a range of -196... +660 C [-321... +1,220
More informationTin-filled multi-entrance fixed point
Tin-filled multi-entrance fixed point D. Zvizdić and D. Šestan Citation: AIP Conf. Proc. 1552, 259 (2013); doi: 10.1063/1.4819550 View online: http://dx.doi.org/10.1063/1.4819550 View Table of Contents:
More informationRealization of the Temperature Scale in the Range from K (Hg Triple Point) to C(Cu Freezing Point) in Croatia
Int J Thermophys (2008) 29:984 990 DOI 10.1007/s10765-008-0412-2 Realization of the Temperature Scale in the Range from 234.3 K (Hg Triple Point) to 1084.62 C(Cu Freezing Point) in Croatia Davor Zvizdic
More informationA quality response to your thermal process requirements
A quality response to your thermal process requirements CALIBRATION EQUIPMENT & SERVICES Silver + 961.78 C 1234.93 K Aluminium + 660.323 C 933.473 K Zinc + 419.527 C 692.677 K Tin + 231.928 C 505.078 K
More information5914A/5915A/5916A 5917A/5918A/5919A Metal Freeze Point Cell. Users Guide
5914A/5915A/5916A 5917A/5918A/5919A Metal Freeze Point Cell Introduction The International Temperature Scale of 1990 (ITS-90) is based on a series of defining fixed points. At temperatures above 273.16
More informationAccreditation of Reference Material Producers
Wilton Park House, Wilton Place, Dublin 2, Ireland Tel +353 1 607 3003 Fax +353 1 607 3109 E-mail inab@inab.ie Web www.inab.ie Accreditation of Reference Material Producers PS21 1) Purpose This statement
More informationAppendix I: Cryogenic Reference Tables
210 Appendix I Cryogenic Reerence Tables Appendix I: Cryogenic Reerence Tables Cryogenic Heat Flow Calculations The heat low Q conducted across small temperature dierences can be calculated using the ormula:
More informationVirtual Institute for Thermal Metrology The evitherm Society Virtual Institute of Thermal Metrology
A new worldwide opportunity for thermal metrology Virtual Institute for Thermal Metrology The evitherm Society 1 The initial implementation of the idea: a 31/2-year EC-funded Project to set up a Virtual
More information2002 An Optimal Gallium Cell Interoperability Between A Cell Made In England And Intercompared At NIST, To It s Reference Cell
2002 An Optimal Gallium Cell Interoperability Between A Cell Made In England And Intercompared At NIST, To It s Reference Cell Speaker/Author: Mr. John P. Tavener., Isothermal Technology Ltd, Pine Grove,
More information5900E. Users Guide. Mercury Triple Point Cell
5900E Mercury Triple Point Cell Users Guide 2004, Rev. 1, 4/11 2004-2011 Fluke Corporation. All rights reserved. Specifications subject to change without notice. All product names are trademarks of their
More informationHIGH TEMPERATURE STANDARD PLATINUM RESISTANCE THERMOMETER MODEL 96178
HIGH TEMPERATURE STANDARD PLATINUM RESISTANCE THERMOMETER Isotech North America 158 Brentwood Drive, Unit 4 Colchester, VT 05446 Phone: (802)-863-8050 Fax: (802)-863-8125 www.isotechna.com sales@isotechna.com
More informationExamples of reference materials
Examples of reference materials JCTLM Working Group for Traceability: Education and Promotion (WG-TEP) Area 2: Mini-presentations to explain scientific concepts What are reference materials? Reference
More informationMAURITAS R3:2017 Issue No. 7:Revision 1 Date: November 2017 MAURITAS. Traceability of measurement. Mauritius Accreditation Service. Copyright MAURITAS
Issue No. 7:Revision 1 MAURITAS R3 Traceability of measurement Mauritius Accreditation Service Copyright MAURITAS CONTENTS FOREWORD... 2 ABOUT MAURITAS PUBLICATIONS... 2 1. PURPOSE... 3 2. SCOPE AND RESPONSIBILITIES...
More informationMeteorology 432. Thermometry Spring 2013
Meteorology 432 Thermometry Spring 2013 General Temperature impacts every day life. Errors of 2-3 ºC are not uncommon in many networks. Bank thermometers or Car thermometers. Errors of this magnitude are
More informationUltraPur TMP. Trimethylphosphite FEATURES & BENEFITS. Canisters and delivery systems APPLICATIONS
SPECIALTY CHEMICALS AND ENGINEERED MATERIALS UltraPur TMP Trimethylphosphite Trimethylphosphite (TMP) is an organic phosphorous ester compound used as a phosphorous source in depositing doped silicate
More informationThe results agree with the manufacturer s specifications for the fixed point cells.
ABSTRACT The Temperature Standard Laboratory of Lithuania is a new laboratory with 4 fixed point cells (H 2 O, Sn, Zn and Al). Within the PRAQIII Fast project: Short term advice on Examination and Quality
More informationPRIMARY LABORATORY COMPARISONS
PRIMARY LABORATORY COMPARISONS John P. Tavener, Managing Director Isothermal Technology Limited Pine Grove, Southport, Merseyside, England. Fax: 44 (0) 1704 544799 E-Mail info@isotech.co.uk INTRODUCTION
More informationA61-01 CALA Traceability Policy Revision 3.2 September 16, 2016
A61-01 CALA Traceability Policy Revision 3.2 September 16, 2016 PAGE II TABLE OF CONTENTS TABLE OF CONTENTS... 1 CALA TRACEABILITY POLICY... 2 1.0 SCOPE... 2 2.0 BACKGROUND... 2 3.0 DEFINITIONS... 3 4.0
More informationMinor Metals essential elements for today s world. Maria Cox General Manager, MMTA
Minor Metals essential elements for today s world Maria Cox General Manager, MMTA What is the MMTA? Founded in 1973 when by-product metals were just starting to be used in growing mass applications Necessary
More informationEmissions Testing Report
National Ceramic Industries Australia 05-May-2014 60305580 Commercial-in-Confidence Emissions Testing Report 2013-14 National Ceramic Industries Australia NATA ACCREDITATION No. 2778 (14391) Accredited
More informationChapter: The Periodic Table
Table of Contents Chapter: The Periodic Table Section 1: Introduction to the Periodic Table Section 2: Representative Elements Section 3: Transition Elements 1 Introduction to the Periodic Table Development
More informationFIXED POINTS FOR SECONDARY LEVEL CALIBRATIONS
FIXED POINTS FOR SECONDARY LEVEL CALIBRATIONS Xumo Li, Mike Hirst Hart Scientific, American Fork, Utah, USA ABSTRACT Fixed-point calibrations have many advantages over comparison calibrations. The unsuitability
More informationCOGNOME Nome Data. 2) Self generating type transducers are transducers? a) Active b) Passive c) Secondary d) Inverse
Tecnologie elettriche/elettroniche TEE classe 5B Prof. De Luca Fortunato (Temperature Transducers n1) COGNOME Nome Data 1) An inverse transducer is a device which converts? a) Electrical quantity into
More informationNATA Policy on Calibration and Measurement Traceability
NATA Policy on Calibration and Measurement Traceability Paul McMullen Sector Manager, Calibration This Session 1. VIM Definitions Calibration and Metrological Traceability 2. Previous Policy on Metrological
More informationWhy is carbon dioxide so important? Examining the evidence
Why is carbon dioxide so important? Examining the evidence In the light of new evidence and taking into account the remaining uncertainties, most of the observed warming over the last 50 years is likely
More informationCERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION
300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com CERTIFICATE OF ANALYSIS tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 ACCREDITATION / REGISTRATION
More informationHow Does Temperature Non-uniformity of an Annealing Furnace Affect SPRT Stability?
How Does Temperature Non-uniformity of an Annealing Furnace Affect SPRT Stability? Speaker: Mingjian Zhao Authors: Mingjian Zhao, Rose Heaton, Rong Ding, Deming Chen, and Matthew Newman Hart Scientific
More informationAvailable online Journal of Scientific and Engineering Research, 2018, 5(1): Research Article
Available online www.jsaer.com, 2018, 5(1):28-34 Research Article ISSN: 2394-2630 CODN(USA): JSRBR Development of High Thermocouples Calibration at NIS-gypt Yasser A. Abdelaziz 1, H. M. Hashem 2, M. M.
More information5944/5945/5946/5947 Mini Metal Fixed Point Cells User s Guide
Hart Scientific 5944/5945/5946/5947 Mini Metal Fixed Point Cells User s Guide Rev. 6C0601 Limited Warranty & Limitation of Liability Each product from Fluke Corporation, Hart Scientific Division ("Hart")
More informationSCC Requirements and Guidance for Calibration and Measurement Traceability in Testing Laboratories
Accreditation Services SCC Requirements and Guidance for Calibration and Measurement Traceability in Testing Laboratories 2017-07-06 Standards Council of Canada 55 Metcalfe Street, Suite 600 Ottawa, ON
More informationAnalysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000
C112-0514M Analysis of Copper and Copper Base Alloys, Using Shimadzu PDA-7000 Copper alloys are designated by their chemical composition with characteristic properties such as high corrosion resistance,
More informationA Primer on Reference Materials Matthew Sica Environmental Program Manager
A Primer on Reference Materials Matthew Sica Environmental Program Manager Overview Related Standards Definitions and types of RMs Data Supporting RMs Use of RMs 2 RM Related Standards ISO Guide 30 Vocabulary
More informationCERTIFICATE OF ANALYSIS 1.0 ACCREDITATION / REGISTRATION 2.0 PRODUCT DESCRIPTION
300 Technology Drive Christiansburg, VA 24073. USA inorganicventures.com CERTIFICATE OF ANALYSIS tel: 800.669.6799. 540.585.3030 fax: 540.585.3012 info@inorganicventures.com 1.0 ACCREDITATION / REGISTRATION
More informationThe table gives some information about a family of molecules in crude oil. Show information from the table in the most appropriate way on the grid.
## The table gives some information about a family of molecules in crude oil. NUMBER OF CARBON ATOMS IN MOLECULE MASS OF MOLECULE (atomic units) 1 16 2 30 4 58 Show information from the table in the most
More informationAM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide
AM1760/1762 Secondary Standard Platinum Resistance Thermometer User s Guide 1/11 Table of Contents Before you start ---- Warnings & Cautions... 3 1 Introduction... 4 1.1 Main Application... 4 1.2 Main
More information2nd Quarter Emissions Testing Report 2013
OneSteel Recycling Pty Ltd 17-Jul-2013 60290660 Commercial-in-Confidence 2nd Quarter Emissions Testing Report 2013 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance
More informationTGA Calibrations, Adjustments & Maintenance. Queens University Belfast 16/02/12
TGA Calibrations, Adjustments & Maintenance Queens University Belfast 16/02/12 Outline Definitions Purpose References Checks Manual calibration Total calibration Flexcal Instruction how to calibrate/adjust
More informationSUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000
SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 100 Fe 200 *** Fe 250 *** Fe 300 Fe 400 Fe 500 Fe 000 Fe low alloy steel cast iron Cr hard / Ni resist stainless steel tool
More informationrealizing ITS-90 temperature calibration equipment & services
realizing ITS-90 Isotech s Millennium Collection of Products for the Primary Temperature Laboratory 2007-8 Edition temperature calibration equipment & services Model No 982 plates For more to information
More informationTEMPERATURE Introduction Portable Dataloggers Product Spotlights Comparison Guide
S E C T I O N 14 C O N T E N T S Introduction............ 14.2 Product Spotlights............... 14.6 Comparison Guide............... 14.7 Portable................ 14.8 Thermocouple...................
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QUALITY CONTROL SERVICES, INC. 2340 SE 11 th Avenue Portland, OR 97214 George Cahill Phone: 503 236 2712 CALIBRATION Valid To: September
More informationUsers Guide. Gallium Melting Point Cell
5943 Gallium Melting Point Cell Users Guide 2004, Rev. 1, 5/11 2004-2011 Fluke Corporation. All rights reserved. Specifications subject to change without notice. All product names are trademarks of their
More informationILAC P10 TRACEABILITY
ACTIVITY 1.3 TRAINING SESSION FOLLOWING THE FINDINGS FROM PREVIOUS ACTIVITIES: ILAC P10 TRACEABILITY Maria Pia Toni Slide 1 of XX REFERENCE ILAC P10:2013 ILAC Policy on the Traceability of Measurement
More informationALL ABOUT METALS. SKG Tutorials - Class 8
ALL ABOUT METALS SKG Tutorials - Class 8 Metals 2 Elements can be classified as metals and non-metals. Metals are strong and durable. Thus metals are used so widely for making almost everything. Example:
More information4th Quarter Emissions Testing Report 2015
OneSteel Recycling Pty Ltd Doc No. 60290660_3.1_Q4 Commercial-in-Confidence 4th Quarter Emissions Testing Report 2015 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance
More informationPlatinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm
Datasheet ENGLISH Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm Precision Pt100 sensor offering high accuracy over the
More informationA.M. MONDAY, 18 January minutes
Candidate Name Centre Number Candidate Number 0 GCSE 240/02 ADDITIONAL SCIENCE IGER TIER CEMISTRY 2 A.M. MONDAY, 18 January 2010 45 minutes ADDITIONAL MATERIALS In addition to this paper you may require
More informationKick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011. Florence Salvetat Head of metrology laboratory
Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 Florence Salvetat florence.salvetat@ifremer.fr Head of metrology laboratory The metrology laboratory: Dedicated to physical and physico-chemical
More informationBORABU-MASABA DISTRICTS JOINT EVALUATION TEST 2012 Kenya Certificate of Secondary Education (K.C.S.E)
Name. School Candidate s Signature. Index No /. Date. 233/2 CHEMISTRY Paper 2 (Theory) JULY / AUGUST - 2012 Time: 2 Hours BORABU-MASABA DISTRICTS JOINT EVALUATION TEST 2012 Kenya Certificate of Secondary
More informationExposing Myths, Legends and Tales About Reference Materials. Presented by: Matt Sica - ANAB Steve Arpie Absolute Joe Konschnik - RESTEK
Exposing Myths, Legends and Tales About Reference Materials Presented by: Matt Sica - ANAB Steve Arpie Absolute Joe Konschnik - RESTEK Overview Reference Materials Accreditation Reference Materials Production
More informationChinese regulations on IVDs and traceability requirements
Chinese regulations on IVDs and traceability requirements Hongmei Li CMD/NRCCRM NIM China NOV 30,2015 at BIPM Outline 1. IVD In China 2. China s Efforts on IVD traceability 3. Future Demands and Tendency
More informationAPPENDIX H TRACEABILITY OF MEASUREMENT
APPENDIX H TRACEABILITY OF MEASUREMENT Table of Contents 1. SCOPE... 2 2. REFERENCES... 2 3. TERMS AND DEFINITIONS... 2 4. BACKGROUND... 6 5. TRACEABILITY OF MEASUREMENT POLICY... 7 7. GUIDANCE ON IMPLEMENTING
More informationrealizing ITS-90 temperature calibration equipment & services
realizing ITS-90 Isotech s Millennium Collection of Products for the Primary Temperature Laboratory 2004 Edition temperature calibration equipment & services The Hyperion R Calibration Bath comprises a
More informationAchievements in monitoring climate change and future challenges for gas metrology
Achievements in monitoring climate change and future challenges for gas metrology Martin J.T. Milton NPL, Teddington, UK Friday 20th July 2012 Varenna Amount fraction [mmol/mol] The Atmosphere Ref CIPM
More informationExtracting Metals by Electrolysis
Extracting Metals by Electrolysis 1 of 17 Boardworks Ltd 2016 Extracting Metals by Electrolysis 2 of 17 Boardworks Ltd 2016 Methods of extracting metals 3 of 17 Boardworks Ltd 2016 Most metals are found
More informationTriple Point of Water Cells
Triple Point of Water Cells Speaker: Xumo Li Hart Scientific, 799 East Utah Valley Drive, American Fork, UT 84003 Phone: 801.763.1600; Fax: 801.763.1010; E-mail: xumo_li@hartscientific.com Paper Authors:
More informationTemperature Calibration Equipment and Services
Temperature Calibration Equipment and Services See page 58 for more information. See page 144 for more information. See page 63 for more information. See page 171 for more information. 2 Table of Contents
More informationP.M. THURSDAY, 15 January minutes
Candidate Name Centre Number Candidate Number 0 GCSE 236/01 SCIENCE FOUNDATION TIER CHEMISTRY 1 P.M. THURSDAY, 15 January 2009 45 minutes For Examiner s use Total Mark ADDITIONAL MATERIALS In addition
More informationContents. Introduction Technical Services Customised Quote Request Form Quality at Reagecon...
Contents Introduction... 4 Technical Services... 5 Customised Quote Request Form... 6 Quality at Reagecon... 7 ICP Standards... 8 IC Standards... 26 Volatile Organic Compounds... 32 www.reagecon.com Phenols...
More informationILAC-P10:01/2013 -Calibration-
ACTIVITY 1.4 TRAININGS OF MOLDAC PERSONNEL INVOLVED IN ACCREDITATION PROCESS INCLUDING THE ISSUE REGARDING THE REQUIREMENTS OF THE NEW VERSIONS OF THE EA, IAF, ILAC DOCUMENTS ILAC-P10:01/2013 -Calibration-
More informationWORKING STANDARD PLATINIUM RESISTANCE THERMOMETER MODEL 909 User Maintenance Manual/Handbook
WORKING STANDARD PLATINIUM RESISTANCE THERMOMETER MODEL 909 User Maintenance Manual/Handbook Isothermal Technology Limited, Pine Grove, Southport, PR9 9AG, England Tel: +44 (0)1704 543830 Fax: +44 (0)1704
More informationA NOVEL METHOD FOR THE IMPROVEMENT IN THERMOELECTRIC PROPERTY OF TIN OXIDE THIN FILMS AND ITS APPLICATION IN GAS SENSING
INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, VOL. 1, NO. 2, JUNE 2008 A NOVEL METHOD FOR THE IMPROVEMENT IN THERMOELECTRIC PROPERTY OF TIN OXIDE THIN FILMS AND ITS APPLICATION IN GAS
More informationDETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, & USING THE AGILENT 5100 ICP-OES
ENVIRONMENTAL ANALYSIS DETERMINATION OF ELEMENTS IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS 10500, 14543 & 13428 USING THE AGILENT 5100 ICP-OES Solutions for Your Analytical Business Markets and
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK A Division of Special Metals Contact: Mr P Scrimshire Wiggin Ltd Tel: +44 (0)1432-352230 Holmer Road Fax: +44 (0)1432-353545 Hereford E-Mail:
More information3rd Quarter Emissions Testing Report 2018
OneSteel 3rd Quarter Recycling Emissions Pty Testing Ltd Report 2018 Commercial-in-Confidence Doc Commercial-in-Confidence No. 60493017_3.1_Q3_2018 60493017 3rd Quarter Emissions Testing Report 2018 OneSteel
More information2nd Quarter Emissions Testing Report 2017
OneSteel 2nd Quarter Recycling Emissions Pty Testing Ltd Report 2017 20-Jun-2017 Doc No. 60493017_2.1_Q2_2017 2nd Quarter Emissions Testing Report 2017 OneSteel Recycling Hexham NATA ACCREDITATION No.
More information2nd Quarter Emissions Testing Report 2016
OneSteel Recycling Pty Ltd Doc No. 60493017_1.2_Q2_2016 Commercial-in-Confidence 2nd Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391) Accredited for compliance
More informationWilmington Police Department Crime Laboratory Quality Management System Procedure Measurement Traceability and Uncertainty
1.0 Purpose This procedure describes how measurement traceability is maintained and measurement uncertainty is calculated and used within the laboratory. The laboratory uses annual equipment calibration,
More information4th Quarter Emissions Testing Report 2016
4th Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.1_Q4_2016 4th Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391)
More informationCRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES
CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Reviewed By: Field
More informationEurachem Workshop Validation, Traceability and MU. May Setting the target measurement uncertainty
Eurachem Workshop Setting the target measurement uncertainty Overview 1. Introduction 3. How to deal with ambiguous information or not updated terminology 4. How to deal with performance variation with
More informationMaterials Criticality Mitigation Options and Impacts
Materials Criticality Mitigation Options and Impacts Dr Adrian Chapman Oakdene Hollins 20 th March 2013 RSC Environmental Chemistry Group, Burlington House What are CRMs? Rare Earths Tungsten What are
More informationtemperature calibration equipment & services
blackbody sources The Florentine Thermometer ISSUE 5 & thermocouple reference equipment temperature calibration equipment & services CONTENTS The Hyperion R Calibration Bath comprises a blackbody Introduction:
More informationPolicy on the Traceability of Measurement Results
Page 1 of 14 Reviewed by: Getnet Tsigemelak Position: Deputy Director General Signature: Approved by: Araya Fesseha Position: Director General Signature: Contents pages 1. Purpose and scope... 2 2. References...
More informationElectronic Supplementary Information
Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 26 Electronic Supplementary Information Condensed phase behaviour of ionic liquid benzene mixtures:
More information3rd Quarter Emissions Testing Report 2016
3rd Quarter Emissions Testing Report 2016 OneSteel Recycling Pty Ltd Doc No. 60493017_1.1_Q3_2016 3rd Quarter Emissions Testing Report 2016 OneSteel Recycling Hexham NATA ACCREDITATION No. 2778 (14391)
More informationSectional Facilities. Central Materials Characterization Facility (CMCF)
Sectional Facilities Central Materials Characterization Facility (CMCF) Inauguration of CMCF A view of CMCF Total no. of instruments = 17 Operated by trained Engineers and supervised by scientists Maintenance
More information