1 Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 Florence Salvetat Head of metrology laboratory

2 The metrology laboratory: Dedicated to physical and physico-chemical parameters: Temperature, pressure, salinity (conductivity), velocity, ocean current, dissolved oxygen, ph, turbidity, fluorescence. Salinometer Fresh water or seawater bath (800l) Towing canal Formazin solutions Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 Fluorescein solutions 2

3 1 Context 2 Main issues 3 On going studies Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 3

4 Context Sharing scientific measurements through international networks Be sure that all measurements are comparable Data quality guarantee Metrology Huge diversity of measurement instruments and technologies Data valorization Traceability to SI units Efforts for international recognition Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 4

5 1 Context 2 Main issues 3 On going studies Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 5

6 Temperature calibration: (Cofrac) Range: -10 C to +60 C with U= +/- 4m C to 13m C Current procedure: comparison in temperature regulated bath for different values of temperature Issues: Reduce uncertainties (few m C) Fresh water or seawater bath (800l) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 6

7 Pressure calibration: (Cofrac) Gauge P: Range: 0.1 MPa to 80MPa with U P Gauge Current procedure: comparison for different values of pressure with a pressure balance Issues: Absolute pressure measured, sea pressure delivered, gauge pressure calibrated Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 7

8 Current calibration: Range: 0.1m/s to 1m/s Current Procedure: comparison for different values of current (mechanical current meter) Issues: Acoustic Doppler current meter: Wall reflexion of the beam Particles spreading needed Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 8

9 Dissolved oxygen calibration: Range: from 0µmol/l to over-saturation Current Procedure: - calibration at 0% (sodium sulphite) and 100% (stirred water) - Winkler titration as standard method Issues: Linearity control: 1 or 2 calibration / adjustment points are not enough Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 9

10 Dissolved oxygen calibration: Issues: Substance matrix: seawater (Winkler s method overestimates dissolved oxygen in seawater: Iodate interference and its oceanographic implication. George T.F. Wong and Kuo-Yuan Li, Marine Chemistry, 2009, vol.115, n 1-2, pp.86,91) Lack of understanding of optical sensors (optodes) behaviour (interferences, corrosion issues, interactions with some materials, ) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

11 Dissolved oxygen calibration: Argo project Ifremer - Argo oxygen meeting - May V. Thierry et al. Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

12 Dissolved oxygen calibration: Argo project Ifremer - Argo oxygen meeting - May V. Thierry et al. Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

13 Dissolved oxygen calibration: Argo project Ifremer - Argo oxygen meeting - May V. Thierry et al. Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

14 ph calibration: Range: from 0 to 14 Current Procedure: calibration with standard ph solutions Issues: Standard matrix: no seawater no Certified Reference Material (no traceability) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

15 Salinity calibration: Range: from 2 to 42 Current Procedure: calibration in temperature regulated bath for different stages of temperature and salinity (natural seawater diluted with fresh water) Issues: No Certified Reference Material (no traceability) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

16 Correction (ms/cm) Main issues Issues: Conductivity sensor response dependent on salinity Sbe37 conductivity correction versus reference conductivity 0,007 0,006 0,005 0,004 0,003 0,002 0,001 Salinité 10 Salinité 10(seconde série) Salinité 15 0,000-0,001-0,002-0, Reference conductivity (ms/cm) Salinité 18 Salinité 22 Salinité 35 Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

17 Turbidity calibration: Range: from 0 to 1000 FNU Current Procedure: calibration with formazin solutions Issues: Not the measurand to achieve (suspended matter) No CRM (no traceability) Lack of understanding of optodes behaviour (signal increasing, decreasing, noisy, interactions with parameters to be found) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

18 Fluorescence calibration: Range: depending on sensor / fluorophore Current Procedure: calibration with fluorescein solutions Fluorescein Issues: Not the measurand to achieve (µg/l vs chlorophyll a or algae estimation) No CRM (no traceability) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

19 Fluorescence calibration: Issues: ph influence on fluorescein Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

20 Sensor signal (µg/l chloro a) Main issues Fluorescence calibration: Issues: Sensor comparison impossible: sensor response dependent on technology 1000 Sensor response with regard to fluorophore OTT & Rhodamin 6G YSI & Rhodamin 6G OTT & Fluorescein YSI & Fluorescein Rhodamin 6G Fluorescein Fluorophore concentration (µg/l) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

21 Fluorescence calibration: Issues: Lack of understanding of optodes behaviour (signal increasing, decreasing, noisy, interactions with parameters to be found) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

22 Traceability? Parameters Temperature Pressure Current O 2 ph Salinity Turbidity Fluorescence YES YES YES / NO YES -> NO YES -> NO NO NO NO (sensor technology) Regulated bath + Pt25 reference thermometer Relative pressure balance Towing canal Regulated bath + Winkler titration Standard ph solution Salinometer calibrated by IAPSO standard Formazin solutions Fluorophore solutions No norm in technology No representativeness (substance matrix, ) No relation to SI units Not universal in regard to the different technologies No reference material or No reference method Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

23 Consequences: Validation issues Validation Calibration Decision criterion Scientific, norm, legal requirement Conformity? Trueness correction U Data + Criterion + Data qualification (Right/Wrong) Data base Data + Calibration results : trueness correction U Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

24 1 Context 2 Main issues 3 On going studies Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

25 On going studies Current calibration: Contact with accreditated laboratories for acoustic Doppler current meter (Metas) Evaluate the calibration feasibility in the towing canal at Brest and in the water vein at Boulogne Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

26 On going studies Oxygen calibration: Characterization of an oxygen multi-level bench Stability: - < 0.5 µm within 1 hour - long stability levels Lowest level: nearly 0% 0 2 homogeneity: < 2µM (! first results) Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

27 On going studies Oxygen calibration: Hypox, Argo projects: Inter-laboratory comparison (Australia, USA, Germany (2), Japan (?), manufacturers): Chemical systems Bubbling systems mixed waters saturated with gas Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

28 Correction (ms/cm) On going studies Salinity calibration: Carry on the investigation on salinity effect 0,007 0,006 0,005 0,004 0,003 0,002 0,001 0,000-0,001-0,002-0,003 Sbe37 conductivity correction versus reference conductivity Reference conductivity (ms/cm) Salinité 10 Salinité 10(seconde série) Salinité 15 Salinité 18 Salinité 22 Salinité 35 Uncertainty budget ENV05 Ocean project Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

29 On going studies Turbidity calibration: Calibration protocols improvements on multiparameter probes (YSI, OTT, NKE): Temperature influence Stirring effect Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

30 Sensor signal (µg/l chloro a) On going studies Fluorescence calibration: Calibration protocols studies on multi-parameter probes (YSI, OTT, NKE, Seapoint, Seatech): fluorophore effect 1000 Sensor response with regard to fluorophore OTT & Rhodamin 6G YSI & Rhodamin 6G OTT & Fluorescein YSI & Fluorescein Fluorophore concentration (µg/l) In situ campaign studies (YSI, OTT, NKE, Seapoint, Seatech) with chlorophyll a sampling. Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

31 On going studies Parameters Temperature Pressure Current O 2 ph Salinity Turbidity Fluorescence YES YES YES / NO YES -> NO YES -> NO NO NO NO (sensor technology) Regulated bath + Pt25 reference thermometer Relative pressure balance Towing canal Regulated bath + Winkler titration Standard ph solution Salinometer calibrated by IAPSO standard Formazin solutions Fluorophore solutions Protocol evaluation New calibration bench (temperature and O 2 regulated/salinity levels) + Uncertainty estimate + Accreditation Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/2011 Uncertainty estimate Salinity influence Calibration Protocols improvements National or international inter-laboratory comparisons projects Metrology laboratory collaboration (eg. Aquaref) 31

32 THANKS FOR YOUR ATTENTION. Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

33 Dissolved oxygen calibration: Argo project Dryness Ifremer - Argo oxygen meeting - May V. Thierry et al. Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

34 Traceability to SI units? Dissolved oxygen calibration: Argo project Self heating depending on sampling Ifremer - Argo oxygen meeting - May V. Thierry et al. Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

35 Some ideas : For New sensors development: Involve metrology in the first steps of development Technical choices Ensure method validation For unknown parameters metrology: - increase collaborations between metrology laboratory concerned (Aquaref) - organise / participate Inter Laboratory Comparisons - operate a number of sensor in parallel to increase results reliability C. Compère Marinera Workshop no.3 Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

36 Some ideas : Recondition sensors in situ (standard signal or reagent) To follow some sensor specifications (qualification of the drift, measurement trueness and repeatability)! : stability of reagent/standard need to be evaluate (degradation and biodegradation, drift, ) C. Compère Marinera Workshop no.3 Kick-off meeting EMRP ENV05 Berlin, 09/20/2011 to 09/21/

EXO ADVANCED WATER QUALITY MONITORING PLATFORM E102-05

EXO ADVANCED WATER QUALITY MONITORING PLATFORM E102-05 EXO ADVANCED WATER QUALITY MONITORING PLATFORM E102-05 Breaking the sonde barrier. EXO represents the intersection of the Environment and Observation and a new generation of monitoring technology. 2 Features

More information

A016 Traceability of measurement results compared to national and international measurement standards

A016 Traceability of measurement results compared to national and international measurement standards 08.04.2016 Version 08 Page 1 de 9 A016 Traceability of measurement results compared to national and international measurement standards Modifications: p 2 South Lane Tower I 1, avenue du Swing L-4367 Belvaux

More information

Examples of reference materials

Examples of reference materials Examples of reference materials JCTLM Working Group for Traceability: Education and Promotion (WG-TEP) Area 2: Mini-presentations to explain scientific concepts What are reference materials? Reference

More information

VALIDATION TRACEABILITY MEASUREMENT UNCERTAINTY CHALLENGES FOR THE 21 ST CENTURY S ANALYSTS

VALIDATION TRACEABILITY MEASUREMENT UNCERTAINTY CHALLENGES FOR THE 21 ST CENTURY S ANALYSTS VALIDATION TRACEABILITY MEASUREMENT UNCERTAINTY CHALLENGES FOR THE 21 ST CENTURY S ANALYSTS Workshop group 2.3: Convener: Steve Ellison Rapporteur: Workshop group 2.3 participants: Kreimeyer, Maria (D)

More information

Procedures for calculating surface water pco 2 /fco 2 from new observing platforms and incorporation into a surface water CO 2 network

Procedures for calculating surface water pco 2 /fco 2 from new observing platforms and incorporation into a surface water CO 2 network Procedures for calculating surface water pco 2 /fco 2 from new observing platforms and incorporation into a surface water CO 2 network Rik Wanninkhof, NOAA/AOML, Miami USA Recommendations and conclusions:

More information

Exposing Myths, Legends and Tales About Reference Materials. Presented by: Matt Sica - ANAB Steve Arpie Absolute Joe Konschnik - RESTEK

Exposing Myths, Legends and Tales About Reference Materials. Presented by: Matt Sica - ANAB Steve Arpie Absolute Joe Konschnik - RESTEK Exposing Myths, Legends and Tales About Reference Materials Presented by: Matt Sica - ANAB Steve Arpie Absolute Joe Konschnik - RESTEK Overview Reference Materials Accreditation Reference Materials Production

More information

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017 Laboratory Page 1 of 17 Laboratory December 6, 2017 2017 by A2LA All rights reserved. No part of this document may be reproduced in any form or by any means without the prior written permission of A2LA.

More information

Macro 900 WQS. Macro 900 Meter completely waterproof, simple to use, rugged for field use

Macro 900 WQS. Macro 900 Meter completely waterproof, simple to use, rugged for field use Macro 900 WQS Macro 900 WQS The Macro 900 Water Quality System is the precise, rugged and customisable multiparameter water quality system for groundwater, aquaculture and environmental monitoring Macro

More information

Preparation Approval Authorisation Application date. Directive Council The President

Preparation Approval Authorisation Application date. Directive Council The President Title Proficiency Testing Reference RT-24 Revision 02 Date 2015-10-27 NOTE: The present document represent the English version of document under reference at the specified revision. In case of conflict

More information

APPENDIX B - QUALITY ASSURANCE AND QUALITY CONTROL PROCEDURES. Interlaboratory Comparison for Wastewater Effluent Analysis

APPENDIX B - QUALITY ASSURANCE AND QUALITY CONTROL PROCEDURES. Interlaboratory Comparison for Wastewater Effluent Analysis APPENDIX B - QUALITY ASSURANCE AND QUALITY CONTROL PROCEDURES Interlaboratory Comparison for Wastewater Effluent Analysis A comparison study was conducted to determine the amount of variability between

More information

Meeting the ISO/IEC Requirements for Traceability and Measurement Uncertainty. APLAC Approaches. Dr Bernard King NARL, Australia

Meeting the ISO/IEC Requirements for Traceability and Measurement Uncertainty. APLAC Approaches. Dr Bernard King NARL, Australia Meeting the ISO/IEC 17025 Requirements for Traceability and Measurement Uncertainty APLAC Approaches Dr Bernard King NARL, Australia Interpretation of ISO/IEC 17025 Requirements Extensive consultation

More information

Navigating the Turbidity Units Standards Around Water Quality Monitoring

Navigating the Turbidity Units Standards Around Water Quality Monitoring Navigating the Turbidity Units Standards Around Water Quality Monitoring A paper edited by: Ludovic Grosjean, OCEANX GROUP Dana Galbraith, OBSERVATOR INSTRUMENTS August 2017 Abstract: This paper presents

More information

TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009

TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009 SANAS Accr. No/s. TECHNICAL AND PRODUCTION REQUIREMENTS of ISO Guide 34:2009 Date/s of evaluation Assessor/s & Observers Facility Area / field of Representative operation This report covers the following:

More information

American Association for Laboratory Accreditation

American Association for Laboratory Accreditation ISO 15189 Page 1 of 17 Accredited clinical laboratories are required to meet the following additional requirements as contained in P905 - A2LA Metrological Traceability Policy for ISO 15189 Laboratory

More information

Optodes to Measure Oxygen in the Aquatic Environment

Optodes to Measure Oxygen in the Aquatic Environment Optodes to Measure Oxygen in the Aquatic Environment By Dr. Anders Tengberg Department of Analytical and Marine Chemistry Göteborg University Göteborg, Sweden Jostein Hovdenes Aanderaa Instruments A/S

More information

What is the purpose of this website?

What is the purpose of this website? What is the purpose of this website? This website aims to explain: How it is possible for different methods to give different results for the same test on the same patient sample Why it is important to

More information

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018

A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018 A24 CALA Checklist for Microbiology Revision 4.1 February 16, 2018 Laboratory Name: Appendix Name: Appendix Number: Assessor: Date: Rev. 4.1 CALA CHECKLIST FOR MICROBIOLOGY Item 01 SAMPLING AND SAMPLE

More information

NATA Policy on Calibration and Measurement Traceability

NATA Policy on Calibration and Measurement Traceability NATA Policy on Calibration and Measurement Traceability Paul McMullen Sector Manager, Calibration This Session 1. VIM Definitions Calibration and Metrological Traceability 2. Previous Policy on Metrological

More information

Thermometry, Spain, CEM (Centro Español de Metrologia), INTA (Instituto Nacional de Técnica Aeroespacial)

Thermometry, Spain, CEM (Centro Español de Metrologia), INTA (Instituto Nacional de Técnica Aeroespacial) Calibration and Capabilities Thermometry, Spain, (Centro Españ de Metrogia), INTA (Instituto Nacional de Técnica Aeroespacial) Calibration or s Measurand Level ange a relative NMI NMI Argon point for SPRT

More information

Real-time Nitrate Monitoring in Streams and Rivers

Real-time Nitrate Monitoring in Streams and Rivers Real-time Nitrate Monitoring in Streams and Rivers Tim Lathrop U.S. Department of the Interior U.S. Geological Survey What is the source of Nitrogen in our water ways? Oxidized soil Nitrogen? Total = 2,180,300

More information

SBE Training Introduction

SBE Training Introduction 2 Module 0: Introduction SBE Training Introduction Welcome to Sea-Bird Electronics training course. The next few slides will show you what we are going to cover in a little more detail. Module 0: Introduction

More information

Calibration Guide. Reliability through traceability

Calibration Guide. Reliability through traceability The Golden Ratio. Ever since the ancient times mathematicians, architects, artists, and composers studied this phenomenon. Even in nature, we find the Golden Ratio. A special measure with special applications.

More information

Using Real-Time Monitoring and Phycocyanin Probes to Track Cyanobacteria Blooms. Tom Faber US EPA New England Regional Laboratory

Using Real-Time Monitoring and Phycocyanin Probes to Track Cyanobacteria Blooms. Tom Faber US EPA New England Regional Laboratory Using Real-Time Monitoring and Phycocyanin Probes to Track Cyanobacteria Blooms Tom Faber US EPA New England Regional Laboratory Measuring Cyanobacteria EPA buoy monitoring program Cyanobacteria cell counts

More information

Carbon. Carbon. Carbon parameters: Carbon

Carbon. Carbon. Carbon parameters: Carbon Carbon Carbon Carbon The main task of a wastewater treatment plant is to reduce the total organic load of wastewater in addition to all the progress made in nitrogen and phosphate elimination. Organic

More information

PERFORMANCE VERIFICATION STATEMENT

PERFORMANCE VERIFICATION STATEMENT PERFORMANCE VERIFICATION STATEMENT for the In-Situ Inc. Dissolved Oxygen RDO Sensor TECHNOLOGY TYPE: APPLICATION: PARAMETERS EVALUATED: TYPE OF EVALUATIONS: Optical sensors In situ measurements of dissolved

More information

CCQM P58.1: Metrology for Clinical Sciences. Diagnostic Formulation Meeting, 24 th Feb James Noble

CCQM P58.1: Metrology for Clinical Sciences. Diagnostic Formulation Meeting, 24 th Feb James Noble CCQM P58.1: Metrology for Clinical Sciences Diagnostic Formulation Meeting, 24 th Feb James Noble Development of a Reference Immunoassay for ctni Cardiac Troponin I (ctni) is an important marker for the

More information

Hach Method Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater

Hach Method Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater Hach Method 10360 Luminescence Measurement of Dissolved Oxygen (LDO ) in Water and Wastewater LED Photo Diode LED Hach Method 10360 Luminescence Measurement of Dissolved Oxygen in Water and Wastewater

More information

Accreditation of Reference Material Producers

Accreditation of Reference Material Producers Wilton Park House, Wilton Place, Dublin 2, Ireland Tel +353 1 607 3003 Fax +353 1 607 3109 E-mail inab@inab.ie Web www.inab.ie Accreditation of Reference Material Producers PS21 1) Purpose This statement

More information

http://www.photonics.com/article.aspx?aid=60709 HARI VENUGOPALAN, CRYSTAL IS INC. UVC LEDs are fast becoming the technology of choice for designers developing a new breed of spectroscopy devices that are

More information

Standard Operating Procedure for:

Standard Operating Procedure for: Standard Operating Procedure for: Eureka Amphibian and Manta Water Quality Multiprobe for Multiple Location Parameter Measurement (1200R02 Eureka Snapshot.doc) Missouri State University and Ozarks Environmental

More information

Mrs. Butler Oceanography

Mrs. Butler Oceanography Mrs. Butler Oceanography InstrumentsLab.doc Instruments Lab This exercise is to be done in the classroom. At each of the seven stations you are to decide what tools or instruments are to be used to conduct

More information

2 QUALITY ASSURANCE PROGRAM

2 QUALITY ASSURANCE PROGRAM 2 QUALITY ASSURANCE PROGRAM Section A. Section B. Introduction Quality Management 1. Quality Management Systems 2. Quality Management Plans 3. Project Plans 4. Laboratory Quality Manual 5. Standard Operating

More information

ab Plasmin Activity Assay Kit (Fluorometric)

ab Plasmin Activity Assay Kit (Fluorometric) ab204728 Plasmin Activity Assay Kit (Fluorometric) Instructions for Use For rapid, sensitive and accurate detection of Plasmin activity. This product is for research use only and is not intended for diagnostic

More information

NIST Special Publication Standard Reference Materials

NIST Special Publication Standard Reference Materials NIST Special Publication 260-136 Standard Reference Materials Definitions of Terms and Modes Used at NIST for Value-Assignment of Reference Materials for Chemical Measurements W. May, R. Parris, C. Beck,

More information

Protocols of the Serial Interface. Available protocols for the serial interface of the BlueBox System. Protocol Export Import Parameter Unit

Protocols of the Serial Interface. Available protocols for the serial interface of the BlueBox System. Protocol Export Import Parameter Unit Available protocols for the serial interface of the BlueBox System Modbus Slave RTU / TCP User def. Modbus Master RTU / TCP (optional) NMEA output (alue,alue,alue ) EMC / KOEM User def. Printer DPU414

More information

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN 1.1 Scope and Application 1.1.1 This spectrophotometric method is used in the determination of chlorophyll a, b, and c, and pheophytin a. This method can be used

More information

Environmental Sustainability through the use of Nalco 3D TRASAR Technology for Sea Water Cooling tower

Environmental Sustainability through the use of Nalco 3D TRASAR Technology for Sea Water Cooling tower Essential Expertise for Water, Energy and Air Environmental Sustainability through the use of Nalco 3D TRASAR Technology for Sea Water Cooling tower Water Arabia Bahrain Feb 2011 1 Sustainability Lasting

More information

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES

CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES CRITERIA FOR PERFORMING CALIBRATION AND INTERMEDIATE CHECKS ON EQUIPMENT USED IN ACCREDITED FACILITIES Prepared by: Technical Manager Approved by: Chief Executive Officer Approval Date: 2017-08-10 Effective

More information

What is Turbidity? John Daly ISA NorCal President South Fork Instruments, Inc.

What is Turbidity? John Daly ISA NorCal President South Fork Instruments, Inc. What is Turbidity? Standards Certification Education & Training Publishing Conferences & Exhibits John Daly ISA NorCal President South Fork Instruments, Inc. Objectives Understand what Turbidity is Investigate

More information

Transport of Total Suspended Matter, Particulate Organic Carbon, Organic Nitrogen and Phosphorus in the Inner Part of Osaka Bay

Transport of Total Suspended Matter, Particulate Organic Carbon, Organic Nitrogen and Phosphorus in the Inner Part of Osaka Bay Journal of Oceanography, Vol. 53, pp. 365 to 371. 1997 Transport of Total Suspended Matter, Particulate Organic Carbon, Organic Nitrogen and Phosphorus in the Inner Part of Osaka Bay TERUMI TANIMOTO and

More information

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK

Laboratory Quality Assurance Manager & Laboratory Assessor RULES & HANDBOOK EOQ Personnel Registration Scheme Laboratory Quality Assurance Manager & RULES & HANDBOOK Prepared by: Dr. Eugenia Soboleva, Quality Austria In accordance with the working group on EOQ product development

More information

Field campaign UBEST1: Ria Formosa - May 30-31, 2017

Field campaign UBEST1: Ria Formosa - May 30-31, 2017 Understanding the biogeochemical buffering capacity of estuaries relative to climate change and anthropogenic inputs Report 3 Field campaign UBEST1: Ria Formosa - May 30-31, 2017 Partners Funding PTDC/AAG-MAA/6899/2014

More information

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx CEMS for Measurement of Ammonia, SO 3, and Low Level NOx McIlvaine Company Hot Topic Hour Richard Himes Senior Project Manager rhimes@epri.com Chuck Dene Senior Project Manager cdene@epri.com October 22,

More information

GLP/SC/01 Basic statistical tools for analytical chemistry (2 days)

GLP/SC/01 Basic statistical tools for analytical chemistry (2 days) GLP Consulting http://consultglp.com Courses on offer (See outlines below) GLP/SC/01 Basic statistical tools for analytical chemistry (2 days) GLP/SC/02 The GUM bottom-up evaluation technique of measurement

More information

Peter H. Linderoth. Save the Sound Western LIS Programs. Peter H. Linderoth Save the Sound, Western LIS Programs. Peter H.

Peter H. Linderoth. Save the Sound Western LIS Programs. Peter H. Linderoth Save the Sound, Western LIS Programs. Peter H. Peter H. Linderoth Save the Sound Western LIS Programs Peter H. Linderoth Save the Sound, Western LIS Programs Peter H. Linderoth Water Quality Program Manager ://www.flickr.com/ Discussion Overview -

More information

Technical Review. Real time PCR

Technical Review. Real time PCR Technical Review Real time PCR Normal PCR: Analyze with agarose gel Normal PCR vs Real time PCR Real-time PCR, also known as quantitative PCR (qpcr) or kinetic PCR Key feature: Used to amplify and simultaneously

More information

Monitoring of a paper mill wastewater treatment plant using UV/VIS spectroscopy

Monitoring of a paper mill wastewater treatment plant using UV/VIS spectroscopy Monitoring of a paper mill wastewater treatment plant using UV/VIS spectroscopy G. Langergraber*, N. Fleischmann*, F. Hofstaedter** and A. Weingartner** * Department for Sanitary Engineering and Water

More information

Available online at ScienceDirect. Procedia Engineering 132 (2015 )

Available online at  ScienceDirect. Procedia Engineering 132 (2015 ) Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 132 (2015 ) 811 815 The Manufacturing Engineering Society International Conference, MESIC 2015 Metrological Regulations for

More information

Triton TR8 Turbidity Analyzer

Triton TR8 Turbidity Analyzer Triton TR8 Turbidity Analyzer The Clear Choice Water to Sludge ELECTRO-CHEMICAL DEVICES What is Turbidity? Standard Methods for the Examination of Water and Wastewater describes Turbidity as an expression

More information

INTRODUCES ITS SOLUTIONS FOR BIOGAS MEASUREMENT

INTRODUCES ITS SOLUTIONS FOR BIOGAS MEASUREMENT March 1 st, 2016 Clermont-Ferrand France For immediate release FUJI ELECTRIC FRANCE IS ATTENDING INDUSTRIAL ANALYSIS EXHIBITION AND INTRODUCES ITS SOLUTIONS FOR BIOGAS MEASUREMENT MARCH 30 AND 31 - BOOTH

More information

Calibration services Meeting our customers needs in the U.S.

Calibration services Meeting our customers needs in the U.S. Products Solutions Services Calibration services Meeting our customers needs in the U.S. Calibration services 2 Calibration services Fulfilling the needs of all industries Does the instrumentation that

More information

How Salty Is Our Water?

How Salty Is Our Water? Title: How Salty Is Our Water? (Water Chemistry) Grade(s): 6-7 Introduction: Corals require a relatively constant environment. However, due to the proximity to the surface of the ocean, the salinity of

More information

Getting Started with ISO in Your Lab: Introduction to Resources, Training, Implementation, and Timelines for Earning Accreditation

Getting Started with ISO in Your Lab: Introduction to Resources, Training, Implementation, and Timelines for Earning Accreditation Getting Started with ISO 15189 in Your Lab: Introduction to Resources, Training, Implementation, and Timelines for Earning Accreditation Topics What is ISO 15189? What is Accreditation? Preparing for Assessment

More information

American Association for Laboratory Accreditation

American Association for Laboratory Accreditation Page 1 of 14 The following pages present R205 Specific s: Calibration Laboratory Accreditation Program (dated September 2005) in checklist format. All laboratories seeking accreditation in the Calibration

More information

Fibrinogen Universal Kit

Fibrinogen Universal Kit Order references Reagents CONT FITUR-B00 Universal kit 1 x 50 ml R1 + 1 x 5 ml R2 FITUR-00 Universal kit 2 x 50 ml R1 + 1 x 15 ml R2 FITUR-C00 Universal kit 2 x 17 ml R1 + 1 x 4 ml R2 Other necessary products

More information

Development of a metrology system difference between legal metrology and industrial metrology

Development of a metrology system difference between legal metrology and industrial metrology COOPERATION IN METROLOGY: Development of a metrology system difference between legal metrology and industrial metrology Manfred Kochsiek Metrology Consultant 1 My professional background Mechanical engineer,

More information

NEW ON-SITE CALIBRATION TECHNIQUE FOR LARGE FLOW METERS USING LASER DOPPLER VELOCIMETRY

NEW ON-SITE CALIBRATION TECHNIQUE FOR LARGE FLOW METERS USING LASER DOPPLER VELOCIMETRY NEW ON-SITE CALIBRATION TECHNIQUE FOR LARGE FLOW METERS USING LASER DOPPLER VELOCIMETRY Mr. Andy Drysdale, Danish Technological Institute Mr. John Frederiksen, Danish Technological Institute Mr. Matthew

More information

Reference systems and international standardisation of measurements for clinically important enzymes

Reference systems and international standardisation of measurements for clinically important enzymes Reference systems and international standardisation of measurements for clinically important enzymes VII th Czech National Congress of Clinical Biochemistry (11. 13.9.2005, Olomouc) Gerhard Schumann, Klinische

More information

APLAC GUIDELINES FOR FOOD TESTING LABORATORIES

APLAC GUIDELINES FOR FOOD TESTING LABORATORIES APLAC GUIDELINES FOR FOOD TESTING LABORATORIES Issue No. 2 Issue Date: 01/08 Page 1 of 13 PURPOSE This document provides guidance to APLAC members and their accredited laboratories on the operation of

More information

Scientific Equipment

Scientific Equipment Scientific Equipment On board Sailing School Vessels Corwith Cramer and Robert C. Seamans Operated by Sea Education Association, Woods Hole, MA, USA Winches: Markey DESF-4 Electric Hydrographic Winch with

More information

Complement C4 Universal Kit

Complement C4 Universal Kit Order references Reagents CONT C4TUR-B00 Universal kit 1 x 50 ml R1 + 1 x 5 ml R2 C4TUR-00 Universal kit 2 x 50 ml R1 + 1 x 15 ml R2 C4TUR-C00 Universal kit 1 x 12 ml R1 + 1 x 2 ml R2 Other necessary products

More information

AlgaeTorch. The handy measurement instrument for rapid deployment. Fast and simple algae monitoring

AlgaeTorch. The handy measurement instrument for rapid deployment.  Fast and simple algae monitoring www.bbe-moldaenke.de The handy instrument for rapid deployment Fast and simple algae monitoring Designed for all types of surface water: lakes, reservoirs, rivers and bathing water What does the offer?

More information

PRINCIPLES FOR THE USE OF SAMPLING AND TESTING IN INTERNATIONAL FOOD TRADE CAC/GL Adopted in Revision: 2015.

PRINCIPLES FOR THE USE OF SAMPLING AND TESTING IN INTERNATIONAL FOOD TRADE CAC/GL Adopted in Revision: 2015. PRINCIPLES FOR THE USE OF SAMPLING AND TESTING IN INTERNATIONAL FOOD TRADE CAC/GL 83-2013 Adopted in 2013. Revision: 2015. CAC/GL 83-2013 2 1. INTRODUCTION Sampling and testing are, among others, procedures

More information

VWR International Ltd

VWR International Ltd Orion Business Campus, Northwest Business Park, Ballycoolin, Blanchardstown, Dublin 15 Calibration Laboratory Registration number: 018C is accredited by the Irish National Board (INAB) to undertake calibration

More information

29682 Roscoff cedex, France. roscoff.fr 2 RDT/DMSI, Ifremer Centre de Brest, Plouzané, France

29682 Roscoff cedex, France. roscoff.fr 2 RDT/DMSI, Ifremer Centre de Brest, Plouzané, France High frequency measurements of hydrological and biological parameters in the Western English Channel: Evidence for a Karenia mikimotoi bloom in july 2010 P. Morin 1, Y. Aoustin 2, E. Macé 1, P. Jégou 2,

More information

For the rapid, sensitive and accurate measurement of Glutamate in various samples.

For the rapid, sensitive and accurate measurement of Glutamate in various samples. ab83389 Glutamate Assay Kit Instructions for Use For the rapid, sensitive and accurate measurement of Glutamate in various samples. This product is for research use only and is not intended for diagnostic

More information

A Bio-Argo pilot network in the Mediterranean Sea

A Bio-Argo pilot network in the Mediterranean Sea A Bio-Argo pilot network in the Mediterranean Sea Maurizio Ribera D Alcalà, SZN Italy Daniele Iudicone, SZN Italy Fabrizio D Ortenzio, LOV, France Louis Prieur, LOV France Vincent Taillandier, LOV France

More information

INTERPRETATION AND GUIDANCE ON THE ESTIMATION OF UNCERTAINTY OF MEASUREMENT IN TESTING

INTERPRETATION AND GUIDANCE ON THE ESTIMATION OF UNCERTAINTY OF MEASUREMENT IN TESTING KAN-G-20 INTERPRETATION AND GUIDANCE ON THE ESTIMATION OF UNCERTAINTY OF MEASUREMENT IN TESTING Issue number : 1 April 2016 Komite Akreditasi Nasional National Accreditation Body of Indonesia Gedung I

More information

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT. PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT CEMS Solution CONTINUOUS, EXTRACTIVE FLUE GAS MONITORING On MCS100E HW, from sampling

More information

MEDICAL EQUIPMENT (1) TOPIC 1: RECORDING AND PROCESSING OF BIOSIGNALS

MEDICAL EQUIPMENT (1) TOPIC 1: RECORDING AND PROCESSING OF BIOSIGNALS MEDICAL EQUIPMENT (1) TOPIC 1: RECORDING AND PROCESSING OF BIOSIGNALS Term 1 2013/14 Prof. Yasser Mostafa Kadah www.k-space.org Measurement Basics Measuring is the experimental determination of a measured

More information

International Standards for Biotechnology

International Standards for Biotechnology Bureau International des Poids et Mesures International Standards for Biotechnology Dr R I Wielgosz BIPM BIPM - 2011 1 International Compatibility of Measurement Standards The task of the BIPM is to ensure

More information

ab MDR Assay Kit (Fluorometric)

ab MDR Assay Kit (Fluorometric) ab112142 MDR Assay Kit (Fluorometric) Instructions for Use For detecting MDR pump activities in cells using our proprietary fluorescence probe. This product is for research use only and is not intended

More information

Status of FerryBox Systems in Europe. Franciscus Colijn and Wilhelm Petersen HZG

Status of FerryBox Systems in Europe. Franciscus Colijn and Wilhelm Petersen HZG Status of FerryBox Systems in Europe Franciscus Colijn and Wilhelm Petersen HZG History of using Ships of Opportunity (SoOs) for Ocean Monitoring 1853 Brussels Conference: systemizing reporting of marine

More information

POTENTIAL IMPACTS OF, AND MITIGATION STRATEGIES FOR, SMALL-SCALE TIDAL GENERATION PROJECTS ON COASTAL MARINE ECOSYSTEMS IN THE BAY OF FUNDY

POTENTIAL IMPACTS OF, AND MITIGATION STRATEGIES FOR, SMALL-SCALE TIDAL GENERATION PROJECTS ON COASTAL MARINE ECOSYSTEMS IN THE BAY OF FUNDY Canadian Science Advisory Secretariat Science Response 2008/013 POTENTIAL IMPACTS OF, AND MITIGATION STRATEGIES FOR, SMALL-SCALE TIDAL GENERATION PROJECTS ON COASTAL MARINE ECOSYSTEMS IN THE BAY OF FUNDY

More information

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo

Analysis of Trace Elements in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo Analysis of Trace s in Seawater Using the Thermo Scientific icap 7000 Series ICP-OES Duo Christos Spanos, Applications Chemist, Thermo Fisher Scientific, Cambridge, UK Application Note 43185 Key Words

More information

PERFORMANCE VERIFICATION STATEMENT for Campbell Scientific CS547A and OBS-3A Salinity Probes

PERFORMANCE VERIFICATION STATEMENT for Campbell Scientific CS547A and OBS-3A Salinity Probes PERFORMANCE VERIFICATION STATEMENT for Campbell Scientific CS547A and OBS-3A Salinity Probes TECHNOLOGY TYPE: APPLICATION: PARAMETERS EVALUATED: TYPE OF EVALUATION: Coupled conductivity and temperature

More information

Joint work with the IAPWS: TOWARDS HARMONISED DEFINITION OF RELATIVE HUMIDITY

Joint work with the IAPWS: TOWARDS HARMONISED DEFINITION OF RELATIVE HUMIDITY Joint work with the IAPWS: TOWARDS HARMONISED DEFINITION OF RELATIVE HUMIDITY CCT Meeting BIPM, 21 May 2014 Martti Heinonen e-mail: martti.heinonen@mikes.fi Overview Introduction Problems with the definition

More information

Update on the revision of ISO/IEC 17025

Update on the revision of ISO/IEC 17025 Presented by: Angelique Botha e-mail: abotha@nmisa.org Update on the revision of ISO/IEC 17025 Date : 1 August 2017 Test and Measurement 2017 Conference and Workshop Overview Background History Timeline

More information

Environmental Monitoring Equipment and in situ Systems. OCN 633 Fall 2013

Environmental Monitoring Equipment and in situ Systems. OCN 633 Fall 2013 Environmental Monitoring Equipment and in situ Systems OCN 633 Fall 2013 Need for monitoring tools in situ measuring devices allow unattended and/or real-time measurements to be made Temporal data provide

More information

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2

Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2 Performance Standards for Indicative Ambient Particulate Monitors Environment Agency July 2012 Version 2 Foreword We set up our Monitoring Certification Scheme (MCERTS) to provide a framework of standards

More information

SAN JUAN BAY ESTUARY PROGRAM

SAN JUAN BAY ESTUARY PROGRAM SAN JUAN BAY ESTUARY PROGRAM May, 2008 Water Quality Monitoring Volunteer Program STANDARD OPERATING PROCEDURES P.O. Box 9509 San Juan, PR 00908-9509 Tel: (787) 725-8165 Fax: (787) 723-8165 Web site: www.estuario.org

More information

Oxelia OXIDATION-ENHANCED BIOLOGICALLY ACTIVE FILTRATION

Oxelia OXIDATION-ENHANCED BIOLOGICALLY ACTIVE FILTRATION Oxelia OXIDATION-ENHANCED BIOLOGICALLY ACTIVE FILTRATION In the battle with hard-to-treat contaminants, drinking water just got a powerful new ally. Leopold Oxelia oxidation-enhanced biologically active

More information

1. INTRODUCTION 2. SAMPLE BOTTLES

1. INTRODUCTION 2. SAMPLE BOTTLES Takeshi Kawano Institute of Observational Research for Global Change (IORGC), Japan Agency for Marine-earth Science and Technology (JAMSTEC), Japan. e-mail: kawanot@jamstec.go.jp 1. INTRODUCTION The method

More information

: Rodger Jeffery (Principal Author); Hardy Engineering Team; Hardy Tech Support Team

: Rodger Jeffery (Principal Author); Hardy Engineering Team; Hardy Tech Support Team Document : AN EXPLANATION OF TRADITIONAL AND C2 CALIBRATION/VALIDATION METHODS & USE Last Revised : Q2 2017 Authors : Rodger Jeffery (Principal Author); Hardy Engineering Team; Hardy Tech Support Team

More information

Ocean Acidification. Presentation to the SCCWRP Commission March 8, 2013

Ocean Acidification. Presentation to the SCCWRP Commission March 8, 2013 Ocean Acidification Presentation to the SCCWRP Commission March 8, 2013 Background At the last Commission meeting, I summarized recommendations from Washington s Blue Ribbon Panel on Ocean Acidification

More information

Event-specific Method for the Quantification of Soybean CV127 Using Real-time PCR. Validation Report

Event-specific Method for the Quantification of Soybean CV127 Using Real-time PCR. Validation Report Event-specific Method for the Quantification of Soybean CV127 Using Real-time PCR Validation Report 20 September 2011 Joint Research Centre Institute for Health and Consumer Protection Molecular Biology

More information

Chemistry Division, Naval Research Laboratory, Washington, DC 23075

Chemistry Division, Naval Research Laboratory, Washington, DC 23075 Ballast Water Sampling using Proportional Flow Control: Evaluating the Utility of External Ultrasonic Flow Meters in the Shipboard Environment Cameron S. Moser 1, Timothy P. Wier 1, Vanessa Molina 1, Scott

More information

Application of Gliders for Near-Real Time METOC Data Collection Capability for Battlespace Characterization

Application of Gliders for Near-Real Time METOC Data Collection Capability for Battlespace Characterization DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Application of Gliders for Near-Real Time METOC Data Collection Capability for Battlespace Characterization Charles Trees

More information

PT-WFD. Proficiency Test 6/10 Polybrominated diphenylether in surface water BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154

PT-WFD. Proficiency Test 6/10 Polybrominated diphenylether in surface water BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154 Analytische Qualitätssicherung Baden-Württemberg PT-WFD Proficiency Test / Polybrominated diphenylether in surface water BDE, BDE, BDE 99, BDE, BDE, BDE provided by AQS Baden-Württemberg at Institute for

More information

SUPPLY PROCUREMENT NOTICE

SUPPLY PROCUREMENT NOTICE SUPPLY PROCUREMENT NOTICE Integrated Monitoring of the Romanian Black Sea Coast between Midia-Vama Veche RO 0103.02-02 Laboratory and Monitoring Component RO 0103.02-03 Ship Component Romania 1. Publication

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Instron Calibration Laboratory 825 University Avenue Norwood, MA 02062-2643 Mr. James O Donovan Phone: 781-575-5526 Fax: 781-575-5764 E-mail: james_odonovan@instron.com

More information

Remediation of 1,2-dichloroethane (1,2-DCA) and vinyl chloride (VC) contaminated groundwater: lab and field pilot test.

Remediation of 1,2-dichloroethane (1,2-DCA) and vinyl chloride (VC) contaminated groundwater: lab and field pilot test. Paper A 31 Remediation of 1,2-dichloroethane () and vinyl chloride (VC) contaminated groundwater: lab and field pilot test. Ing. Claudio Sandrone 1, Ing. Paola Goria 1, Ing. Marcello Carboni 1, Dott. Luca

More information

H2020 JERICO-NEXT PROJECT. 7 th Ferrybox Workshop

H2020 JERICO-NEXT PROJECT. 7 th Ferrybox Workshop H2020 JERICO-NEXT PROJECT www.jerico-ri.eu email: jerico@ifremer.fr 7 th Ferrybox Workshop The JERICO-NEXT Approach Platforms/sensors Innovation / SMEs Value Creation WP2 - Harmonisation WP3 - Developments

More information

A nucleic acid-based fluorescent sensor for expeditious detection of pyrophosphate anions at nanomolar concentrations

A nucleic acid-based fluorescent sensor for expeditious detection of pyrophosphate anions at nanomolar concentrations Supporting Information for A nucleic acid-based fluorescent sensor for expeditious detection of pyrophosphate anions at nanomolar concentrations Xin Su, Chen Zhang, Xianjin Xiao, Anqin Xu, Zhendong Xu

More information

RATA/Compliance Testing. Judith Aasland

RATA/Compliance Testing. Judith Aasland RATA/Compliance Testing Judith Aasland jaasland@montrose-env.com October 1, 2014 Overview RATAs/Compliance Tests ASTM D7036 Standard: Source Testing Accreditation Protocol Gas Verification Program (PGVP)

More information

Total NAD and NADH Assay Kit (Colorimetric)

Total NAD and NADH Assay Kit (Colorimetric) ab186032 Total NAD and NADH Assay Kit (Colorimetric) Instructions for Use An optimized assay for monitoring Total NAD and NADH. This product is for research use only and is not intended for diagnostic

More information

NEW ANALYZER FOR VISCOSITY MEASUREMENT AT REFERENCE TEMPERATURE

NEW ANALYZER FOR VISCOSITY MEASUREMENT AT REFERENCE TEMPERATURE NEW ANALYZER FOR VISCOSITY MEASUREMENT AT REFERENCE TEMPERATURE Dr. Luc K. Bellière, Dr. Valerie Lefèvre Sofraser Villemandeur, France Corentin Thierry Sofraser USA Houston, TX, USA KEYWORDS VISCOSITY,

More information

Development of an immunoassay-based measurement procedure of higher metrological order for ctni. James Noble Date: 30/11/11

Development of an immunoassay-based measurement procedure of higher metrological order for ctni. James Noble Date: 30/11/11 Development of an immunoassay-based measurement procedure of higher metrological order for ctni James Noble Date: 3/11/11 Analytical requirements of a RMP 1. Comparable ctni specificity to commercial assays

More information

Will Accrediting Authorities allow PT Providers to reissue a result report if the lab identifies a reporting problem? Sponsor: Bill Hall Resolution:

Will Accrediting Authorities allow PT Providers to reissue a result report if the lab identifies a reporting problem? Sponsor: Bill Hall Resolution: Will Accrediting Authorities allow PT Providers to reissue a result report if the lab identifies a reporting problem? Sponsor: Bill Hall Resolution: Accrediting Authorities will not accept re-issued reports

More information

Salinity in Seawater

Salinity in Seawater Salinity in Seawater Objective To familiarize students with the different methods used for measuring salinity of water. Introduction: Salinity exerts profound impacts on the marine environment. It controls

More information