GI-150 SAMPLE BOTTLE GUIDE
|
|
- Clement Hood
- 6 years ago
- Views:
Transcription
1 GI-150 SAMPLE BOTTLE GUIDE CHEMICAL ANALYSIS INORGANIC BIOLOGICAL GENERAL RADIOACTIVITY HEAVY METALS MERCURY NUTRIENTS - TOTAL NUTRIENTS - FILTERABLE 600mL Plastic 100mL Glass 120mL Plastic (GL100) (PT120) ALGAL & ODOURS CHLOROPHYLL 1 L Black Plastic (BLKPT1) A B PT600 None None No, Ice PT1250 None None No, Ice PT355 Acid Washed None, Ice GL100 Acid Washed None, Ice PT355 None None No, Ice A. PT120 None None - Filtered Air gap, Ice B. PT120 None None - Air gap, Ice PT355 None None Air BLKPT1 None None Air General Cations (7 days) **ph (6 hours) *Conductivity (28 days) *Colour (48hrs),*Turbidity (24hrs) *Alkalinity (24 hours) **Gross Alpha & Beta (28 days) *All Metals (excluding Mercury) (28 days) Includes cations Calcium, Magnesium, Sodium and Potassium *Mercury (28 days) *Chloride (28 days) *Fluoride (28 days) *OXN (28 days) *Ammonia (28 days) *TKN (28 days) *Total P (28 days) ***Blue Green Algae, see preservation below ***Odour Test *Chlorophyll (24-48 Hours) Container is pre acid washed with Green Lid Container is pre acid washed with Blue Lid. Place containers in double zip locked bags to avoid lids being contaminated. Filtered Sample will require filter equipment Algae holding time increased to 28 days when preserved with Lugol s solution Freshwater samples 1:100 by volume Marine samples 1:200 by volume Version 1.0.D 20/02/2015 Page 1 of 5
2 WASTEWATER GENERAL AND BOD CYANIDES SULPHIDES GREASE & OILS PHENOLS SLUDGES, SOLIDS, & SOILS 600mL Plastic 1L Glass (GL1000) 1L Amber Glass (AG1000) 500mL Plastic Pot (PP500) SLUDGE & SEDIMENTS (Microbiological analyses) Plastic Pot GIARDIA & CRYPTOSPORIDIUM (wastewater only) 2 x PT1250 None None No, Ice PT600 None NaOH No, Ice PT355 None Zinc Acetate, Ice GL1000 None None, Ice AG1000 None None No, Ice PP500 None None None PT600 Sterile Sodium Thio, Ice PT1250 Sterile Sodium Thio, Ice *Biological Oxygen Demand *Suspended Solids (24 hrs) *Chemical Oxygen Demand (28 days) *Cyanide (24 hours) *Sulphides, 28 days for preserved samples 24 hours for non preserved samples *Grease (28 days) *MBAS (48hrs) ** (24 Hours) #E.coli (24 hours), Filamentous bacteria Amoebae Naegleria fowleri (48hrs as per in-house valid.) Cryptosporidium and Giardia (48 hours as per USEPA 1623) NaOH pellet dosed Samples to be taken in predosed container. Do not rinse. Fill initially with small air gap, invert to mix pellets, squeeze out remaining air. Zinc Acetate Dosed Samples to be taken with the minimum amount of aeration and the bottle completely filled Caution to not overfill container Required to place pot in double zip locked bags Aseptic preparation is mandatory Place bottles in double zip locked bags for storage on ice Aseptic Preparation is mandatory 2x1.25L Pet Bottles be used Version 1.0.D 20/02/2015 Page 2 of 5
3 CHEMICAL ANALYSIS ORGANIC PHENOL VCH NDMA MX GENERAL ALGAL TOXINS MIB/GEOSMIN, TCA 355ml Plastic 10L Plastic 1L Glass (GL1000) (APT1250 Alfoil wrapped) (JC1) DOC, TOC, MIB, GEOSMIN, TCA, HAAFP, THMFP, GLYPHOSATE DISINFECTION by PRODUCTS 355ml Plastic 600ml Plastic PT1250 None - Ammonium Chloride No, Ice ***Halogenated Phenols PT355 None Ascorbic Acid, Ice ***VCH APT1000 None Sodium Thio, Ice ***NDMA JC1 None Ascorbic Acid, Ice ***MX GL1000 None None No Air ***Organochlorides ***Organophosphates ***Acid herbicides ***GCMSSCANs ***Diesel, VOC, BTEX, MTBE, Fipronyl, Haloxyfop ***Atrazine metabolites, Simazine ***Formaldehyde TPH/TRH PT1250 None None, Ice ***MIB, GEOSMIN ***TCA are performed by CLSA for lower detection limits. ***Algal Toxins PT355 None None No Air ***Dissolved Organic Carbon, Total Organic Carbon ***Total Carbon ***MIB, GEOSMIN, TCA ***Glyphosate ***Formation Potential of THM and HAA PT355/PT600 None Ammonium Chloride No Air ***Haloacetic Acids ***Chloracetic Acids ***DBP_551 ***THM 100mg/L Ammonium Chloride dosed 250mg/L Ascorbic Acid dosed 150mg/L Sodium Sulphite for Chloramine < 4.0mg/L Wrap entire bottle in foil. Amber glass bottles or black plastic bottles can be used. 5g Ascorbic Acid dosed Amber glass bottle can also be used. 100mg/L Ammonium Chloride dosed Single analysis 355mL bottle is sufficient for > 2 analyses 600mL bottle required Version 1.0.D 20/02/2015 Page 3 of 5
4 MICROBIOLOGICAL GENERAL LEGIONELLA SULPHITE & SULPHATE REDUCING BACTERIA 300 / 600mL Sterile Plastic 300mL Sterile Plastic 300mL Sterile Plastic (PT300 / 600) (PT300) (PT300) CAMPYLOBACTER & SALMONELLA 2 x 600mL Sterile Plastic # Holding times as per AS/NZS2031 ICE AMOEBAE CRYPTOSPORIDIUM & GIARDIA Plastic Pot 600mL Sterile Plastic 2 x10l Plastic (JC1) PT300 / 600 Sterile Sodium Thio, Ice PT300 Sterile Sodium Thio, Ice PT300 Sterile Sodium Thio, Ice, Ice, Ice, No Ice JC1 Sterile Sodium Thio Air #E.coli (24 hours) #Faecal Coliforms (24 hours) #Enterococcus (24 hours) #Iron Bacteria (24 hours) #Pseudomonas (24 hours) #Plate Counts (24 hours) #Bacteriophages and f RNA phage ( 24 hours) #Legionella (24 hours) Samples from Warm or Hot Water Systems require NO FLUSHING or flame sterilisation of sample tap prior to sampling. #Sulphite reducing Clostridia including Clostridium perfringens (24 hours) #Sulphate Reducing Bacteria (24 hours) #Campylobacter (C.jejuni, C.coli) (24hours) #Salmonella spp.(24 hours) #E.coli (24 hours), ***Amoebae Naegleria fowleri (48 hours as per in-house validation) AMOEBAE samples are not to be chilled Cryptosporidium and Giardia (48 hours as per USEPA 1623) 2x 600mL bottles to be used. Aseptic preparation is mandatory Place bottles in double zip locked Not Iced or chilled bags. Aseptic Preparation is mandatory 2x10L Plastic Containers (jerry cans) to be used. Version 1.0.D 20/02/2015 Page 4 of 5
5 Version 1.0.D 20/02/2015 Page 5 of 5
STATE ENVIRONMENTAL LABORATORY SERVICES DIVISION
STATE ENVIRONMENTAL LABORATORY SERVICES DIVISION FY18 ANALYTICAL FEE SCHEDULE Adjusted to correspond with Consumer Price Index (CPI) of 1.013 APPENDIX A. SAMPLES SUBMITTED BY GOVERNMENT ENTITIES Gas Chromatography/Mass
More informationSurface Water Samples: Containers, Preservation and Hold Times Table
Surface Water Samples: Containers, Preservation and Hold Times Table North Carolina Division of Water Resources, Water Sciences Section Chemistry Laboratory Reference: 40 CFR Part 136.3 Table II Listed
More informationDrinking Water Quality and Compliance SaskWater Wakaw-Humboldt Potable Water Supply System and Treatment Plant 2016 Notification to Consumers
Drinking Water Quality and Compliance SaskWater Wakaw-Humboldt Potable Water Supply System and Treatment Plant 2016 Notification to Consumers The Water Security Agency (WSA) requires that, at least once
More informationCATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS. The temperature shall not exceed 28 degrees Celsius.
Updated 21 Dec. 2005 CATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS 1 PHYSICAL CHARACTERISTICS (a) Temperature The temperature shall not exceed 28 degrees Celsius. (b) Solids The suspended solids concentration
More informationSCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS
SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,
More informationCITY OF ST. LOUIS Water Quality Report 2016
CITY OF ST. LOUIS Water Quality Report 2016 In compliance with the Safe Drinking Water Act, the City of St. Louis Water Division is delivering this Water Quality Report to all its customers who receive
More informationSDWA TABLE OF SAMPLE PRESERVATION AND HOLDING TIME REQUIREMENTS ORGANIC ANALYSIS Table 6-1
SDWA TABLE OF SAMPLE PRESERVATION AND HOLDING TIME REQUIREMENTS Table 6-1 *504.1 EDB/DBCP Na 2 S 2 O 3 3mg/40ml Extract and analyze within 505 Organohalide Pesticides and PCB s Na 2 S 2 O 3 3mg/40ml Extract
More informationThe City of Columbus. Water Quality Monitoring in Central Ohio
The City of Columbus Water Quality Monitoring in Central Ohio Presentation Overview Water Quality Assurance Laboratory Primary Responsibilities Four Sections Water Treatment Research Biological/ Environmental
More informationBOTTLED WATER QUALITY REPORT. FIJI WATER COMPANY W. Olympic Boulevard Los Angeles, CA INTRODUCTION OUR SOURCE FOR OUR WATER
BOTTLED WATER QUALITY REPORT FIJI WATER COMPANY 11444 W. Olympic Boulevard Los Angeles, CA 90064 877.426.3454 INTRODUCTION FIJI Water, a natural artesian water, meets all federal and state health standards.
More informationJordan Water Company/ Miyahuna Production and Quality Directorate Quality Control and Assurance Department Service Price List
Service List 1 Color Color Materials/Products Tested: Water (Surface, Ground, Effluent & Distributed Water) PHYSICAL TESTS SM 1 B - Visual Comparison Method - Standard Method for Examination of Water and
More informationJordan Water Company/ Miyahuna. Quality, Laboratories and Water Safety Department. Service Price List
Materials/Products Tested: Water (Surface, Ground, Effluent & Distributed Water) 1 Turbidity (Lab) 3 Turbidity (Field Test) 4 Odor 5 Total Alkalinity 6 Phenolphthalein Alkalinity 7 Total Hardness 8 9 Electrical
More informationBenefits of On-line Monitoring of Carbon, Nitrogen and Phosphorus
Benefits of On-line Monitoring of Carbon, Nitrogen and Phosphorus New Jersey Water Environment Association Dan Davis Shimadzu Scientific Instruments Benefits of On-Line Monitoring Environment Consumers
More information4.0 SAN GABRIEL RIVER WATERSHED MANAGEMENT AREA
4.0 SAN GABRIEL RIVER WATERSHED MANAGEMENT AREA 4.1 Watershed Description 4.1.1 Watershed Land Use, Percent Impervious, and Population Land use in the San Gabriel River Watershed Management Area is approximately
More information2.0 Test Records - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards (BIS).
SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PACKAGED DRINKING WATER (OTHER THAN PACKAGED NATURAL MINERAL WATER) ACCORDING TO IS 14543:2004 (Incorporating Amendment No. 1 to 7) 1.0 Laboratory
More informationRECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY
RECYCLED WATER AT SYDNEY OLYMPIC PARK Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY INTEGRATED URBAN WATER CYCLE AT SYDNEY OLYMPIC PARK - CONTEXT INTRODUCTION TO SYDNEY OLYMPIC PARK INTEGRATED WATER
More informationWater Quality Changes in the Distribution System. Module 6
Water Quality Changes in the Distribution System Module 6 Learning Objectives Be able to describe what different water quality parameters tell us about distribution system health Be able to describe and
More informationCentral Laboratory, M.P. Pollution Control Board, Bhopal [M.P.]
Central Laboratory, M.P. Pollution Control Board, Bhopal [M.P.] General Sampling Guideline Prepare a Sampling and Analysis Plan which describes the sampling locations, numbers and types of samples to be
More informationThe supply of safe, clean drinking water to all customers is a top priority at
The supply of safe, clean drinking water to all customers is a top priority at anglianwater.co.uk Drinking water quality in 2008 Contents 02 Foreword 03 Drinking water quality in 2008 Drinking water compliance
More informationDrinking Water Analyses
Environmental & Analytical Services 350 Hills Street, Suite 107, Richland, WA 99354 (509) 377-8058 FAX (509) 377-8464 ANALYSES AND PRICE LIST, JANUARY 2016 TO DECEMBER 2016 Drinking Water Analyses BACTERIOLOGICAL
More informationLABORATORY TURNAROUND TIMES AND CHARGES
LABORATORY TURNAROUND TIMES AND CHARGES The enclosed prices reflect a 5 business day turnaround time. There will be a $25.00 minimum charge per report. Same Day Rush 24 Hour Rush 48 Hour Rush 72 Hour Rush
More informationPRODUCT SPECIFICATION 500ml STILL SPORTS CAP
PRODUCT SPECIFICATION 500ml STILL SPORTS CAP Product name: Legal name: 500ml Still Spring Water Sports Cap Princes Gate Still Spring Water 500ml Sports Cap Date issued / revision number: 22/02/2014 Issue
More informationAcceptance standards and charging rates for
Industrial customers Acceptance standards and charging rates for 2017-18 Sydney Water accepts trade wastewater to the wastewater system, if it meets certain acceptance standards. What are acceptance standards?
More informationADDENDUM #004. Laboratory Analysis on Water Treatment Plants, Wastewater Treatment Plants, and Groundwater Wells
ADDENDUM #004 Solicitation Number: Solicitation Title: Opening Date/Time: FDC ITB-15-142 Laboratory Analysis on Water Treatment Plants, Wastewater Treatment Plants, and Groundwater Wells December 8, 2016
More informationGERBER PURE Water. Primary Inorganics Antimony
Primary Inorganics Antimony 0.001 0.006 ND Arsenic 0.002 0.01 ND Asbestos (MFL) 0.2 7 ND Barium 0.1 2 ND Beryllium 0.001 0.004 ND Cadmium 0.001 0.005 ND Chromium 0.01 0.1 ND Cyanide 0.1 0.2 ND Fluoride
More information2014 Annual Water Quality Report
01 Annual Water Quality Report This report is designed to inform you about the quality water we delivered to you over the past year. If you have any questions about this report or concerning your water
More informationTolerance and Classification
Tolerance and Classification As per ISI-IS: 2296-1982, the tolerance limits of parameters are specified as per classified use of water (Table 1,2,3,4,5 below) depending on various uses of water. The following
More informationKKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana
Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m
More informationNitrogen, Simplified TKN (s-tkn ) DOC
Nitrogen, Simplified Total Kjeldahl, TNTplus 880, 10242 DOC316.53.01258 s-tkn Method Method 10242 0 to 16 mg/l TKN TNTplus 880 Scope and Application: For water and wastewater. Digestion is required. Test
More informationCLEAN WATER Clean Water PT Scheme Schedule Clean Water PT Scheme Schedule. Schedule subject to change see ERA s website at
For International purchase only: Synthetic drinking water matrices with low concentrations of analytes for testing water supply, drinking water, or ground water. Standards are designed to meet the requirements
More informationCity of Lake Jackson 2004 Drinking Water Quality Report
City Lake Jackson 2004 Drinking Water Quality Report OUR DRINKING WATER IS SAFE This report is a summary the quality the water we provide our customers. The analysis was made by using the data from the
More informationEnvironmental. National Legionella Conference Sample Taking Workshop. Right Solutions Right Partner
Environmental National Legionella Conference Sample Taking Workshop www.alsglobal.com Introductions Ashley Radbourne Senior Project and Field Services Manager Cassandra Hogan Business Development Officer
More information2004 Annual Drinking Water Quality Report
Annual Drinking Water Quality Report (Consumer Confidence Report) BMWD SOUTHSIDE Phone No: (210) 922-1221 Special Notice for the ELDERLY, INFANTS, CANCER PATIENTS, people with HIV/AIDS or other immune
More informationHaryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date
Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide
More information2016 Water Quality Report to Consumers
2016 Water Quality Report to Consumers Is Our Water Safe To Drink? Absolutely! Ascension Consolidated Utilities District #2 is proud of the fine drinking water it provides. This 19th annual water quality
More informationThink-Pair-Share. How does EPA set MCL Standards? Water Quality Standards & Factors. Waterborne Pathogens. Discuss with another student:
Think-Pair-Share Discuss with another student: What water contamination issues do you think about most often? What are the relative merits of bottled vs. tap water? 1 2 Water Quality Standards & Factors
More informationBackground Statement for SEMI Draft Document 4651 REVISION OF SEMI F GUIDELINES FOR ULTRAPURE WATER USED IN SEMICONDUCTOR PROCESSING
Background Statement for SEMI Draft Document 4651 REVISION OF SEMI F63-0701 GUIDELINES FOR ULTRAPURE WATER USED IN SEMICONDUCTOR PROCESSING Note: This background statement is not part of the balloted item.
More informationSRI RAMAKRISHNA INSTITUTE OF TECHNOLOGY COIMBATORE First Year BE/B.TECH ( ) Engineering Chemistry- I
SRI RAMAKRISHNA INSTITUTE OF TECHNOLOGY COIMBATORE-641010 1. Define hard water and soft water? First Year BE/B.TECH (2012-2013) Engineering Chemistry- I UNIT-I- Water Technology Water which does not produce
More informationEnvironment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra
Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D
More informationTown of Rutland 2015 Drinking Water Quality Report Public Water Supply #
Drinking Water Quality Report Our goal is to provide our customers with high quality drinking water that meets all state and federal standards for quality and safety. We have made significant investments
More information2016 Consumer Confidence Report
2016 Consumer Confidence Report Water System Name: Marine Corps Logistics Base NEBO 3610701 Report : May 2017 We test the drinking water quality for many constituents as required by state and federal regulations.
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9
Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 %
More informationArizona Water Issues The University of Arizona - HWR203 1
1 Think-Pair-Share Discuss with another student: What water contamination issues do you think about most often? What are the relative merits of bottled vs. tap water? 2 What water contamination issues
More informationFOOD PRODUCTION WATER SUPPLIES
FOOD PRODUCTION WATER SUPPLIES SAFOODNET (SSA) 3 rd Open seminar Dr. Mehlika Borcakl 5 May 2009 Tallinn Water Sources v Most food processors use water from city and municipal suppliers or from wells. v
More informationOxygen Demand, Chemical
, TNTplus 820, 10211 DOC316.53.01103 USEPA Reactor Digestion Method Method 10211 ULR (1 60 mg/l COD) TNTplus 820 Scope and Application: For wastewater, process water, surface water, and cooling water;
More information2013 Water Analysis Report
Volatile Organic Compounds Benzene 0.0005 0.005 ND Carbon tetrachloride 0.0005 0.005 ND Chlorobenzene (Monochlorobenzene) 0.0005 0.100 ND 1,2-Dichlorobenzene (o-dcb) 0.0005 0.600 ND 1,4-Dichlorobenzene
More informationIsabelle Papineau, Ph.D., École Polytechnique de Montréal Yves Dionne (V de G) and Benoit Barbeau (EPM)
Isabelle Papineau, Ph.D., École Polytechnique de Montréal Yves Dionne (V de G) and Benoit Barbeau (EPM) 16 th Canadian National Conference on Drinking Water October 28th 2014 1. Background City of Gatineau
More informationMethod (0.1 to 8.0 mg/l Cu) TNTplus 860
Chlorine, Total, Bulk Powder, 8167 DOC316.53.01255 Bathocuproine Method 1 Method 10238 (0.1 to 8.0 mg/l Cu) TNTplus 860 Scope and Application: For water, wastewater and process water. Digestion may be
More informationUSEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.
, MF, m-tec, 8367 DOC316.53.001210 USEPA Membrane Filtration Method Method 8367 1 m-tec Scope and Application: For potable water, nonpotable water, recreation water and wastewater. 1 USEPA accepted. Test
More informationENVIRONMENTAL LABORATORY LICENSE. ACZ Laboratories, Inc. AZ0102
ARIZONA DEPARTMENT OF HEALTH SERVICES ENVIRONMENTAL LABORATORY LICENSE Issued to: Laboratory Director: Owner/Representative: Brett Dalke Matt Sowards ACZ AZ0102 is in compliance with Environmental Laboratory
More informationINCHEM Tokyo Current Status and Implementation Approach for Industrial Zones Wastewater Management In Yangon Region
INCHEM Tokyo 2017 Current Status and Implementation Approach for Industrial Zones Wastewater Management In Yangon Region Than Than Thwe Director, Ministry of Construction Joint Secretary-1, Thilawa SEZ
More informationFinal Report DMR-QA 36. NPDES Permit: IL DMR-QA Study. Open Date: 03/18/16. Close Date: 07/01/16. Report Issued Date: 07/29/16
Keith Richard Decatur Sanitary District Decatur, IL 62522-1842 USA DMR-QA 36 Final Report NPDES Permit: IL0028321 DMR-QA Study Open Date: 03/18/16 Close Date: 07/01/16 Report Issued Date: 07/29/16 Study
More informationBOTTLE GUIDE MARKET LEADING PROVIDER OF LABORATORY AND CONSULTANCY SERVICES.
BOTTLE GUIDE MARKET LEADING PROVIDER OF LABORATORY AND CONSULTANCY SERVICES Latis Scientific Unit C1 Acorn Industrial Estate Crayford Road Crayford, Kent DA1 4AL Tel: 0044 (0)20 8853 3900 info@latisscientific.co.uk
More informationWater Quality. CE 370 Lecture 1. Global Distribution of Earth s s Water
Water Quality CE 370 Lecture 1 Global Distribution of Earth s s Water Water Demand and Supply in Saudi Arabia Total Water Consumption = 22 billion m 3 /Year Water Demand Water Supply Industrial Domestic
More informationChlorate Working Group
Chlorate Working Group Drinking Water Treatment V0 1 May 2016 Why Our journey Jan 2015: 23,000 people on a BWN 121 WSZs on RAL The Challenge 49% UFW Over 33% of our WTPs do not have 15% headroom What brought
More informationPage 2. Introduction Page 3. Who should read this brochure? Page 3. Analytical Capability Page 4. Landfill analyses available Page 4
Landfill Analysis Page 2 Table of Contents Introduction Page 3 Who should read this brochure? Page 3 Analytical Capability Page 4 Landfill analyses available Page 4 Closed Landfills Page 6 Leaching Procedures
More informationBy Authority Of THE UNITED STATES OF AMERICA Legally Binding Document
By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has
More informationLagoons Operation and Management in New Brunswick
Lagoons Operation and Management in New Brunswick Lagoons Provide secondary treatment to domestic wastewater by the action of bacteria stabilizing the organic matter in the wastewater. Benefits of lagoons:
More informationMicro Methods Laboratory Quality Assurance Manual
15.2 List of Approved Methods Petroleum Analysis Methodology Reference Table Method ASTM 977 ASTM C25 ASTM C39 ASTM D129 ASTM D1298 ASTM D156 ASTM D1744 ASTM D189 ASTM D2159 ASTM D2270 ASTM D2276 ASTM
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
ANSI-ASQ National Accreditation Board/ACLASS I. Microbiological / Biological ITEMS, MATERIALS OR, water and, water and, water and, water and, water and, water and, water and SCOPE OF ACCREDITATION TO ISO/IEC
More informationSODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS
SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS Presented at ALBERTA Public Works, Supply & Services Property Management Operations Division Water Treatment Co-ordinators'
More informationPocket Guide. Safe Drinking Water Act (SDWA) Chemical & Radiological Compliance Sampling. July 2016 Accurate Environmental Laboratories 1
Safe Drinking Water Act (SDWA) Chemical & Radiological Compliance Sampling Pocket Guide (For EPA Region 6 Tribal Water Systems) July 2016 Accurate Environmental Laboratories 1 2 Pocket Guide Contents Introduction
More informationDover Water Company (PWSID#: NJ ) 100 Princeton Avenue, Dover, NJ Year 2017 Annual Water Quality Report
Dover Water Company (PWSID#: NJ1409001) 100 Princeton Avenue, Dover, NJ 07801 Year 2017 Annual Water Quality Report What s The Quality of Your Water? Dover Water Company is proud to supply you with this
More informationBoss Water Systems Australia Reverse Osmosis System Model 021-4P-GM
Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM Congratulations on your purchase of the most advanced water purifier system available! Installation and Service Guide short web version,
More informationDR 1900 PORTABLE SPECTROPHOTOMETER
DR 1900 PORTABLE SPECTROPHOTOMETER Applications Drinking Water Wastewater Field Use Industrial Water Power Carry more water methods with you wherever you need them most. The DR 1900 combines the ruggedness
More informationTESTING SERVICES by Analyte
BACTERIOLOGY Finished Drinking Water Coliform, Total AND Fecal AND E.coli Multiple Tube (10 Tube, 1 Dilution) SM 9221A, B, E, CFR 141.21(f)(6)(i) Coliform, Total AND E. Coli (MMO-MUG) Colilert Presence
More informationDISCUSSION PAPER. 1 Introduction. 2 Existing Legislation and Guidelines
DISCUSSION PAPER Arrowsmith Water Service Englishman River Water Intake Study Phase 1 Conceptual Planning Discussion Paper 4-2 Drinking Water Quality Criteria Prepared by: Keith Kohut and Matt Henney Issued:
More informationLaboratory # 1. Measurement of Water Quality Parameters
CEE 311 Environmental Engineering I Fall 2015 Laboratory # 1 Dr. Jagadish Torlapati Engineering Objectives Measurement of Water Quality Parameters 1. To learn about parameters that characterize water quality
More informationHow to Collect Your Water Sample and Interpret the Results for the Poultry Analytical Package
How to Collect Your Water Sample and Interpret the Results for the Poultry Analytical Package Bradley J. Austin, Josh B. Payne, Susan E. Watkins, Mike Daniels, and Brian E. Haggard Arkansas Water Resources
More informationColiforms, Total and E. coli
Coliforms, Total and E. coli DOC316.53.01213 m-coliblue24 Broth PourRite Ampules 1 Method 10029 Scope and application: For potable water, nonpotable water, recreation water and wastewater. 1 USEPA accepted.
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Laboratory locations: i54 Business Park Valiant Way Wolverhampton
More informationProposal by Russia to delete hot sub-spot Hot sub-spot name South-West Wastewater Treatment Plant
Proposal by Russia to delete hot sub-spot 18.4 LAND 14/2009, Document 6/3/Rev.1 ATTACHMENT 1. Hot sub-spot name South-West Wastewater Treatment Plant 2. Location Block 2, 123, Volkhonskoye shosse, St.
More informationCOOLING TECHNOLOGY INSTITUTE
PAPER NO: CATEGORY: TP15-18 TREATMENT EVALUATION COOLING TECHNOLOGY INSTITUTE ALTERNATIVE TO BROMINE IMPROVES COOLING WATER MICROBIAL CONTROL AND OVERALL TREATMENT ANDREW BOAL, PhD MIOX CORPORATION The
More informationSUSQUEHANNA RIVER MONITORING:
SUSQUEHANNA RIVER MONITORING: Monitoring the fecal coliform bacteria and water quality in the Upper Susquehanna River, summer 2002 Selinda Schlierman 1 ABSTRACT As part of a long-term, ongoing study by
More information2015 Annual Drinking Water Quality Report
Annual Drinking Water Quality Report (Consumer Confidence Report) GALVESTON COUNTY WCID #8 PWS ID NUMBER TX0840009 PHONE # 409-925-2821 Special Notice for the ELDERLY, Our Drinking Water INFANTS, CANCER
More informationPhysicochemical and microbiological quality of water from a pilot domestic rainwater harvesting facility in Ireland.
Dublin Institute of Technology ARROW@DIT Articles School of Civil and Structural Engineering 211-12-1 Physicochemical and microbiological quality of water from a pilot domestic rainwater harvesting facility
More informationA Method to Determine Biodegradable Dissolved Organic Nitrogen in Water ND 58108, USA
A Method to Determine Biodegradable Dissolved Organic Nitrogen in Water Tanush Wadhawan a, Halis Simsek a, Murthy Kasi a, Kristofer Knutson b, John McEvoy c, Birgit Pruess c and Eakalak Khan a* a Department
More informationAmerican Water College 2010
Vocabulary Disinfection Air Gap An open vertical drop, or vertical empty space, that separates a drinking (potable) water supply to be protected from another water system in a water treatment plant or
More informationPage 2. Why do we need safe water? Page 4. Small Community and Individual Drinking Water Supplies
Water Potability Page 2 Table of Contents Why do we need safe water? Page 4 Small Community and Individual Drinking Water Supplies The Domestic Water Suite Page 5 E.coli only Page 5 Lead from your taps
More informationMR. D HR UV AS HE R I.C.S.E. BOA RD PAP ER ICSE
MR D HR UV AS HE R ICSE BOA RD PAP ER 200 4 1 ICSE-2004 Section A (40 Marks) (Attempt all questions from this section) Question 1 (a) Choose the letters A,B,C or D to match the descriptions (i) to (iv)
More informationPHE Food and Water Microbiology Proficiency Testing Schemes
Schedules: 1 January to 31 December 2014 PHE Food and Water Microbiology Proficiency Testing Schemes 0006 we aim to meet all the dates in this document you will be advised as soon as possible if any changes
More informationWarm Mineral Springs Sampling by Sarasota County
Warm Mineral Springs Sampling by Sarasota County John Ryan, Kathryn Meaux, Rene Janneman and Jon S. Perry Sarasota County Environmental Services Sarasota, Florida September 11 Warm Mineral Springs is a
More informationHI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified
HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to 44 Measurement Methods ISO 9001:2000 Certified www.hannainst.com/usa HI 83200 2 0 0 8 S E R I E S Multiparameter Photometers with up to
More informationICSE-Science 2 (Chemistry) 2004
ICSE-Science 2 (Chemistry) 2004 Answers to this Paper must be written on the paper provided separately. You will not be allowed to write during the first 15 minutes. This time is to be spent in reading
More informationWater quality assessment of a wastewater treatment plant in a Ghanaian Beverage Industry
Vol. 5(5), pp. 272-279, May, 213 DOI IJWREE-23.3.13-41 ISSN 2141-6613 213 Academic Journals http://www.academicjournals.org/ijwree International Journal of Water Resources and Environmental Engineering
More informationQUALITY REPORT Image of Barton Dam by Farzin Montazersadgh
ANN ARBOR WATER QUALITY REPORT 1 QUALITY REPORT Image of Barton Dam by Farzin Montazersadgh Safe Reliable Affordable Quality drinking water is an essential resource. The good news is that your tap water
More informationWater Company of Green Valley June Water Quality Report
Water Company of Green Valley June 2013 2012 Water Quality Report Serving our community by providing reliable delivery of drinking water since 1977 Community Water Company is pleased to present this annual
More informationWhat Determines water Quality? Well Maintenance Well water Testing AZ survey on individual systems water quality Final remarks
Private Water Wells 1# 1 Overview Numbers Regulations What Determines water Quality? Well Maintenance Well water Testing AZ survey on individual systems water quality Final remarks Private Wells In AZ
More informationWATER QUALITY REPORT
P R I S T E G WATER QUALITY REPORT PROUD SOURCE WATER, PRISTINOCKY MOUNTAIN SPRING WATER, SOURCE MEETS ALL FEDERAL AND STATE HEALTH STANDARDS. BOTTLED WATER IS REGU- LATED BY THE FDA AND IS CLASSIFIED
More informationApplication Notes for COD Analysis DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER.
DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER. INTRODUCTION The chemical oxygen demand can be considered as an approximate measurement of the theoretical oxygen consumption, i.e.,
More informationLaboratory Fee Schedule
JMLord, Inc. Laboratory Fee Schedule Spring 2011 www.jmlordinc.com 267 N. Fulton St. Fresno CA, 93705 (559) 268-9755 (559) 486-6504 (FAX) Laboratory Services Since 1976, JMLord, Inc. has provided consultants
More informationMembrane Bioreactor vs. Extended Aeration Treatment Pilot Study Effluent and Groundwater Quality Presenter Leslie Dumas
Membrane Bioreactor vs. Extended Aeration Treatment Pilot Study Effluent and Groundwater Quality Presenter Leslie Dumas Innovative Solutions for Water and the Environment September 15, 2009 Acknowledgements
More informationAmerican Water College 2010
Vocabulary Pond Treatment Aerobic Bacteria Bacteria which will live and reproduce only in an environment containing oxygen which is available for their respiration (breathing), namely atmospheric oxygen
More informationOxygen Demand, Chemical
without chloride removal, 10067 Manganese III Reactor Digestion Method (without chloride removal) 1 30 to 1000 mg/l COD Mn Scope and Application: For water and wastewater 1 U.S. Patent 5,556,787 DOC316.53.01102
More informationUS EAS 12 UGANDA STANDARD. First Edition Potable water Specification. Reference number US EAS 12: 2014
UGANDA STANDARD US EAS 12 First Edition 2014-10-15 Potable water Specification Reference number US EAS 12: 2014 UNBS 2014 US EAS 12: 2014 Compliance with this standard does not, of itself confer immunity
More informationMicrobiological Quality: Understanding Drinking Water Quality and Management
S A S K A T C H E W A N Microbiological Quality: Understanding Drinking Water Quality and Management June 2017 EPB 197 Table of Contents Page Number How to Determine the Microbiological Quality... 1 Monitoring
More information2016 Consumer Confidence Report
2016 Consumer Confidence Report Water System Name: Marine Corps Logistics Base Yermo Annex 3610702 Report : May 2017 We test the drinking water quality for many constituents as required by state and federal
More informationMethod 5.9 Syrup: calcium and magnesium by EDTA titration
Section 5: Syrup and remelt p 1/6 Method 5.9 Syrup: calcium and magnesium by EDTA titration 1. Rationale The method is applicable to all syrups and uses two separate direct EDTA titrations to determine
More informationTest sticks and test papers for semi-quantitative determinations
QUANTOFIX test sticks for semi-quantitative determinations QUANTOFIX test sticks meet the most important requirements for a modern quick-test: rapid dip and read convenient the analysis can be carried
More information