RETAINING WALL INSIDE (NEGATIVE SIDE) - PREREQUISITE FOR SUPERSHIELD WATERPROOFING TREATMENT
|
|
- Clifford Barton
- 5 years ago
- Views:
Transcription
1 RETAINING WALL INSIDE TWO COATS OF 1.5 Kg/m RETAINING WALL OUT IN CRYSTALGUARD FIRST COATING CRYSTALGUARD SECOND COATING RETAINING WALL INSIDE (NEGATIVE SIDE) - PREREQUISITE FOR WATERPROOFING TREATMENT l The RETAINING WALL INSIDE (NEGATIVE SIDE) that is to be treated should be minimum 7 days old. SPECIFICATION AND APPLICATION METHODOLOGY Concrete Substrate Provide, mix and brush apply two coats of CRYSTALGUARD, single compound Deep Penetrating Capillary (DPC) waterproofing system that generates a non-soluble crystalline formation of dendritic fibers within the pores and capillary tracts of the 1.5 Kg/m² for two coats on the inside of the retaining wall (Negative Side). Application Methodology 1) Surface preparation - The concrete substrate that is to be applied with CRYSTALGUARD must be free from foreign materials and to be micro cleaned by mechanical means like wire brushing or vacuum cleaning. 2) Pre-wetting - Concrete surface must be thoroughly saturated with clean water prior to the coating to ensure moisture presence inside the pores and capillaries and remove any excess water and ensure surface is touch dry while coating. 3) Mixing of CRYSTALGUARD - Mix CRYSTALGUARD powder with clean water to form a slurry consistency with 5 parts of powder and 2 parts of water. 4) Application of CRYSTALGUARD - Apply the first coat of CRYSTALGUARD as a slurry consistency on the concrete surface. RETAINING WALL INSIDE Page 1 of 3
2 RETAINING WALL INSIDE TWO COATS OF 1.5 Kg/m 5) Second coat of CRYSTALGUARD - Apply the second coat of CRYSTALGUARD as a slurry consistency on the first coat after a minimum of 4 hours gap. Curing l The CRYSTALGUARD coating should be cured with a misty fog spray of clean water, 24 hours after the application and to be kept moist for minimum 3 days. Watch Points Cracks, horizontal, vertical joint sealing, tie hole, pipe penetrations, construction joints, expansion joints and other defects in the concrete that is to be waterproofed should be treated as per the specification and application methodology. Performance Criteria Crystalline waterproofing system should meet or exceed the performance requirements as specified herein. l Crystalline Penetration : Crystallizing capability of waterproofing material shall be evidenced by l independent SEM (Scanning Electron Microscope) photographs documenting penetration of needle like crystal formation deep within concrete. l Self-healing capability and permeability resistance : Independent testing performed according to U.S. Army Corps of Engineers CRD-C48-73 "Permeability of Concrete". l Testing on the effectiveness of coating from negative side of concrete : Independent testing that demonstrates the capability of the coating to seal the leakage/dampness from negative side. l Resistance to chloride ion penetration : Independent testing performed according to ASTM C should exhibit a resistance of 100% better than that of the untreated specimen. l Potable Water Approval : Independent testing shall be performed according to EN or NSF Standard 61, and approval for use of waterproofing material on structures holding potable water shall be evidenced. Quality Assurance A) Manufacturer : Manufacturer should publish a third party product quality assurance certificate from a notified body with continuous surveillance audit or CE certificate with FPC (Factory Production Control) as per the harmonized standard EN to prove that the facility from where the material is produced for the project has undergone the required testing and extensive inspection and is under continuous surveillance by a notified body appointed by the European Union as per the European norms for the system. Manufacturers who cannot provide the performance test data specified herein and FPC certificate shall not be considered for the project. B) Applicator : Waterproofing applicator shall be experienced in the installation of cementitious crystalline waterproofing materials and shall be approved by the manufacturer in writing. RETAINING WALL INSIDE Page 2 of 3
3 RETAINING WALL INSIDE TWO COATS OF 1.5 Kg/m Warranty A) Manufacturer's Warranty : Manufacturer shall provide standard product warranty executed by authorised company official. B) Applicator's Warranty : Applicator shall warrant the waterproofing installation against defects caused by faulty workmanship or materials for a period of (specify term) years from Date of Substantial Completion. The warranty will cover the surfaces treated and will bind the applicator to repair, at his expense, any and all leaks through the treated surfaces which are not due to structural weaknesses or other causes beyond applicator's control such as fire, earthquake and cyclone. Submittals Product data sheets, Application guidelines, Material safety data sheet, CE certificate, Summary of test reports. RETAINING WALL INSIDE Page 3 of 3
4 RETAINING WALL INSIDE 102 ONE COAT OF CRYSTALGUARD & ONE COAT OF CRYSTALGUARD 1.5 Kg/m² RETAINING WALL OUT IN CRYSTALGUARD COATING CRYSTALGUARD ULTIMA COATING RETAINING WALL INSIDE (NEGATIVE SIDE) - PREREQUISITE FOR WATERPROOFING TREATMENT l The RETAINING WALL INSIDE (NEGATIVE SIDE) that is to be treated should be minimum 7 days old. SPECIFICATION AND APPLICATION METHODOLOGY Concrete Substrate Provide, mix and brush apply one coat of CRYSTALGUARD, single compound Deep Penetrating Capillary (DPC) waterproofing 0.75 Kg/m² and one coat of CRYSTALGUARD ULTIMA, single compound highly concentrated crystalline coating as a top coat that generates a non-soluble crystalline formation of dendritic fibers within the pores and capillary tracts of the concrete with hard surface 0.75 Kg/m² on the inside of the retaining wall inside (Negative Side). Application Methodology 1) Surface preparation - The concrete substrate that is to be applied with CRYSTALGUARD /ULTIMA must be free from foreign materials and to be micro cleaned by mechanical means like wire brushing or vacuum cleaning. 2) Pre-wetting - Concrete surface must be thoroughly saturated with clean water prior to the coating to ensure moisture presence inside the pores and capillaries and remove any excess water to ensure surface is touch dry while coating. 3) Mixing of CRYSTALGUARD - Mix CRYSTALGUARD powder with clean water to form a slurry consistency with 5 parts of powder and 2 parts of water. RETAINING WALL INSIDE Page 1 of 3
5 RETAINING WALL INSIDE 102 ONE COAT OF CRYSTALGUARD & ONE COAT OF CRYSTALGUARD 1.5 Kg/m² 4) Application of CRYSTALGUARD - Apply one coat of CRYSTALGUARD as a slurry consistency on the concrete surface. 5) Mixing of CRYSTALGUARD ULTIMA - Mix CRYSTALGUARD ULTIMA powder with clean water to form a slurry consistency with 5 parts of powder and 2 parts of water. 6) Application of CRYSTALGUARD ULTIMA - Apply one coat of CRYSTALGUARD ULTIMA as a slurry consistency on the CRYSTALGUARD coating minimum after 4 hours gap as a top coating. Curing l The CRYSTALGUARD/ ULTIMA coating should be cured with a misty fog spray of clean water, 24 hours after the application and to be kept moist for minimum 3 days. Watch Points Cracks, horizontal, vertical joint sealing, tie hole, pipe penetrations, construction joints, expansion joints and other defects in the concrete that is to be waterproofed should be treated as per the specification and application methodology. Performance Criteria Crystalline waterproofing system should meet or exceed the performance requirements as specified herein. l Crystalline Penetration : Crystallizing capability of waterproofing material shall be evidenced by l independent SEM (Scanning Electron Microscope) photographs documenting penetration of needle like crystal formation deep within concrete. l Self-healing capability and permeability resistance : Independent testing performed according to U.S. Army Corps of Engineers CRD-C48-73 "Permeability of Concrete". l Testing on the effectiveness of coating from negative side of concrete : Independent testing that demonstrates the capability of the coating to seal the leakage/dampness from negative side. l Resistance to chloride ion penetration : Independent testing performed according to ASTM C should exhibit a resistance of 100% better than that of the untreated specimen. l Potable Water Approval : Independent testing shall be performed according to EN or NSF Standard 61, and approval for use of waterproofing material on structures holding potable water shall be evidenced. Quality Assurance A) Manufacturer : Manufacturer should publish a third party product quality assurance certificate from a notified body with continuous surveillance audit or CE certificate with FPC (Factory Production Control) as per the harmonized standard EN to prove that the facility from where the material is produced for the project has undergone the required testing and extensive inspection and is under continuous surveillance by a notified body appointed by the European Union as per the European norms for the system. Manufacturers who cannot provide RETAINING WALL INSIDE Page 2 of 3
6 RETAINING WALL INSIDE 102 ONE COAT OF CRYSTALGUARD & ONE COAT OF CRYSTALGUARD 1.5 Kg/m² the performance test data specified herein and FPC certificate shall not be considered for the project. B) Applicator : Waterproofing applicator shall be experienced in the installation of cementitious crystalline waterproofing materials and shall be approved by the manufacturer in writing. Warranty A) Manufacturer's Warranty : Manufacturer shall provide standard product warranty executed by authorised company official. B) Applicator's Warranty : Applicator shall warrant the waterproofing installation against defects caused by faulty workmanship or materials for a period of (specify term) years from Date of Substantial Completion. The warranty will cover the surfaces treated and will bind the applicator to repair, at his expense, any and all leaks through the treated surfaces which are not due to structural weaknesses or other causes beyond applicator's control such as fire, earthquake and cyclone. Submittals Product data sheets, Application guidelines, Material safety data sheet, CE certificate, Summary of test reports. RETAINING WALL INSIDE Page 3 of 3
SEWAGE/ EFFLUENT TREATMENT PLANT - PREREQUISITE FOR SUPERSHIELD WATERPROOFING TREATMENT
SEWAGE / EFFLUENT TREATMENT PLANT 101 TWO COATS OF CRYSTALGUARD @ 1.5 Kg/m² CONCRETE STRUCTURE CRYSTALGUARD FIRST CRYSTALGUARD SECOND SEWAGE/ EFFLUENT TREATMENT PLANT - PREREQUISITE FOR WATERPROOFING TREATMENT
More informationDryshake CSI Format Section 07160
Dryshake CSI Format Section 07160 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Furnishing of all labor, materials, services and equipment necessary for the supply and installation of cementitious crystalline
More informationCoatings CSI Format Section 07160
Coatings CSI Format Section 07160 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Furnishing of all labor, materials, services and equipment necessary for the supply and installation of cementitious crystalline
More informationSECTION SURFACE-APPLIED CRYSTALLINE WATERPROOFING AND CONCRETE REPAIR
SECTION PART 1 GENERAL 1.1 SECTION INCLUDES A. Surface-applied crystalline waterproofing treatment. B. Crystalline compounds for the repair of leaking cracks, holes and joints found in concrete. 1.2 RELATED
More informationCSI SPECIFICATIONS SURFACE-APPLIED CRYSTALLINE WATERPROOFING Section
SURFACE-APPLIED CRYSTALLINE WATERPROOFING Section 07 16 16 This section includes Krystol T1 crystalline waterproofing, applied to new or existing concrete substrates, above or below grade, on either dry
More informationHydrophilic Crystalline Waterproofing of Concrete-Admixture
Hydrophilic Crystalline Waterproofing of Concrete-Admixture Kryton International Inc. SECTION 03305 Hydrophilic Crystalline Waterproofing of Concrete Admixture PART 1 GENERAL 1.1 SECTION INCLUDES - A.
More informationCSC SPECIFICATIONS SURFACE-APPLIED CRYSTALLINE WATERPROOFING Section
SURFACE-APPLIED CRYSTALLINE WATERPROOFING Section 07 16 16 This section includes Krystol T1 & T2 crystalline waterproofing, applied to new or existing concrete substrates, above or below grade, on either
More informationCSI SPECIFICATIONS SURFACE-APPLIED CRYSTALLINE WATERPROOFING Section
SURFACE-APPLIED CRYSTALLINE WATERPROOFING Section 07 16 16 This section includes Krystol T1 & T2 crystalline waterproofing, applied to new or existing concrete substrates, above or below grade, on either
More informationCSI SPECIFICATIONS CRYSTALLINE WATERPROOFING LEAK REPAIR Section
CRYSTALLINE WATERPROOFING LEAK REPAIR Section 03 01 30 This section includes Krystol Leak Repair System consisting of Krystol Plug, Krystol Repair Grout and Krystol T1 Crystalline Waterproofing. The Krystol
More informationCSI MASTERFORMAT SPECIFICATIONS. krystol internal membrane (kim ) Section 03 & 07 - Integral Crystalline Waterproofing of Concrete
Concrete Waterproofing Admixture 1 of 5 krystol internal membrane (kim ) Section 03 & 07 - Integral Crystalline Waterproofing of Concrete PART 1 GENERAL 1.01 SUMMARY Section Includes: Furnishing of all
More information3.0 XYPEX SPECIFICATIONS. CSI Format Schematic Drawings
3.0 XYPEX SPECIFICATIONS CSI Format Schematic Drawings 03 3. CSI FORMAT CSI FORMAT What is CSI Format?... 05 Crystalline Waterproofing Coating... 06 Crystalline Waterproofing Additive... 4 Crystalline
More information3.0 XYPEX SPECIFICATIONS. CSI Format Schematic Drawings
3.0 XYPEX SPECIFICATIONS CSI Format Schematic Drawings 121 CSI FORMAT What is CSI Format?... 125 Crystalline Waterproofing Coating... 126 Crystalline Waterproofing Additive... 134 Crystalline Waterproofing
More informationGUIDE SPECIFICATION SECTION CRYSTALLINE WATERPROOFING
GUIDE SPECIFICATION SECTION 071616 PART 1 - GENERAL CRYSTALLINE WATERPROOFING 1.1 SECTION INCLUDES A. Cementitious Crystalline Waterproofing on concrete structures and surfaces as shown on drawings and
More informationCEMENTITIOUS CRYSTALLIZING WATERPROOFING PART 1 GENERAL
CEMENTITIOUS CRYSTALLIZING WATERPROOFING PART 1 GENERAL 1.1 SECTION INCLUDES A. Cementitious crystallizing waterproofing for interior/exterior walls and floor slabs with nonactive leaks. B. Cementitious
More informationCSC SPECIFICATIONS DRY SHAKE CRYSTALLINE WATERPROOFING Section
DRY SHAKE CRYSTALLINE WATERPROOFING Section 03 35 14 This section includes Krystol Broadcast, a crystalline waterproofing powder applied to the surface of freshly placed concrete during the final stages
More informationCSI SPECIFICATIONS DRY SHAKE CRYSTALLINE WATERPROOFING Section
DRY SHAKE CRYSTALLINE WATERPROOFING Section 03 35 14 This section includes Krystol Broadcast, a crystalline waterproofing powder applied to the surface of freshly placed concrete during the final stages
More informationMulti-Institutional Academic Health Science & Research Center Evansville, IN
SECTION 07 1616 - CRYSTALLINE WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationB. All work of the section shall comply with the conditions of the contract, the drawings and any special conditions forming a part of the contract.
SPECIFICATIONS PART ONE - GENERAL ------------------------------------------------------------------------ 1.01 General Description A. The Cementitious capillary waterproofing materials specified herein
More informationCSC SPECIFICATIONS CRYSTALLINE WATERPROOFING ADMIXTURE Section
CRYSTALLINE WATERPROOFING ADMIXTURE Section 03 05 15 Krystol Internal Membrane (KIM) is a chemical admixture in powder form used to create waterproof concrete. KIM is used in place of externally applied
More informationConstruction Standards PAGE
Construction Standards PAGE 071619-1 SECTION 071619 PART 1 - GENERAL 1.1 M.S.U. ISSUES A. Below grade construction should be protected by self-adhering sheet waterproofing in accordance with SECTION 071326
More informationCopyright 2002 AIA MASTERSPEC 05/02
SECTION 07162 - CRYSTALLINE WATERPROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More information3.0 XYPEX SPECIFICATIONS. CSI Format Schematic Drawings
3.0 XYPEX SPECIFICATIONS CSI Format Schematic Drawings 03 3. CSI FORMAT CSI FORMAT What is CSI Format?... 05 Crystalline Waterprooing Coating... 06 Crystalline Waterprooing Additive... 4 Crystalline Waterprooing
More information2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL. A. Two component liquid waterproofing for positive side waterproofing on mineral substrates
2 COMPONENT LIQUID WATERPROOFING PART 1 GENERAL 1.1 SECTION INCLUDES A. Two component liquid waterproofing for positive side waterproofing on mineral substrates 1.2 REFERENCES A. CE / EN1504-2 : 2005 Surface
More informationDIVISION 7-THERMAL & MOISTURE PROTECTION Section Cementitious & Reactive Waterproofing
Component: SC-057-03/10 SikaTop 144 DIVISION 7-THERMAL & MOISTURE PROTECTION Section 07160 - Cementitious & Reactive Waterproofing DIVISION 9 - FINISHES Section 09880 - Protective Coatings Part 1 General
More informationA. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.
TECHNICAL SPECIFICATIONS SEWER MANHOLE REHABILITATION SYSTEM WITH A PROTECTIVE CEMENT LINER AND HIGH BUILD EPOXY COATING (As Provided by Standard Cement Materials) FOREWORD The following specification
More informationDIVISION 7-THERMAL & MOISTURE PROTECTION Section Cementitious & Reactive Waterproofing
Component: SC-057-03/10 SikaTop 144 DIVISION 7-THERMAL & MOISTURE PROTECTION Section 07160 - Cementitious & Reactive Waterproofing DIVISION 9 - FINISHES Section 09880 - Protective Coatings Part 1 General
More informationTHOROSEAL CPB 1. Capillary/Crystallising waterproofing, surface applied slurry for use on concrete and mortar. Description of product. Benefits.
THOROSEAL CPB 1 Capillary/Crystallising waterproofing, surface applied slurry for use on concrete and mortar Description of product THOROSEAL CPB 1 is a waterproofing system for waterproofing concrete
More informationConcrete Waterproofing by Crystallization
ADMIX C-SERIES Concrete Waterproofing by Crystallization WATERPROOFING PERFORMANCE...RIGHT WATERPROOF & PROTECT YOUR CONCRETE AS YOU POUR IT IMPROVING CONCRETE Xypex Admix Now! Concrete, by its nature
More information***********************************************************************************
AQUAFIN-2K/M Two-Component Cement-based Acrylic-based Waterproofing GUIDE AQUAFIN, Inc. SPECIFICATION PART 1 - GENERAL 1.1 SECTION INCLUDES SECTION 07 16 14 ACRYLIC MODIFIED (FLEXIBLE) CEMENTITIOUS WATERPROOFING
More informationPROJECT NAME: PROJECT ADDRESS: Farmers Market Structural Repairs 4-6 Gordon Street Guelph, Ontario DATE: November, 2010 I N D E X Page(s) Index... 1 to 1 Introduction... 1 to 1 DIVISION 04 - MASONRY Section
More informationDIVISION 9 - FINISHES Section Protective Coatings
Spec Component: SC-202-03/10 SikaTop Seal 107 DIVISION 9 - FINISHES Section 09880 - Protective Coatings Part 1 - General 1.01 Summary A. This specification describes the coating of substrates with a non-vapor
More informationSECTION DAMPPROOFING AND WATERPROOFING
SECTION 07100 DAMPPROOFING AND WATERPROOFING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Sheet Membrane Waterproofing 2. Under-Slab-On-Grade Vapor Retarder B. Related Sections: 1. Section 03300
More informationSECTION Fiber Reinforced Stucco 1
CSI SECTION 09200 FIBER REINFORCED STUCCO PART 1 GENERAL 1.01 SUMMARY A. Section Description: Provided lath and plaster where shown on the Drawings, as specified herein, and as needed for complete and
More informationCSI SPECIFICATIONS CRYSTALLINE WATERPROOFING ADMIXTURE FOR SHOTCRETE Section
CRYSTALLINE WATERPROOFING ADMIXTURE FOR SHOTCRETE Section 03 05 15 Krystol Internal Membrane (KIM) is a chemical admixture in powder form used to create waterproof concrete. KIM is used in place of externally
More informationSECTION RESINOUS FLOORING
SECTION 09705 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section includes all materials and installation necessary to provide resinous flooring system with integral cove base and top finish
More informationSECTION CLEAR PENETRATING SEALERS SPECIFICATION
MANUFACTURER S GUIDE SPECIFICATIONS SECTION 071900 CLEAR PENETRATING SEALERS SPECIFICATION 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisle-ccw.com Carlisle is a trademark of Carlisle. 2012 Carlisle.
More informationSECTION (07100) - DAMPPROOFING AND WATERPROOFING
SECTION 07 10 00 (07100) - DAMPPROOFING AND WATERPROOFING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Sheet Membrane Waterproofing 2. Under-Slab-On-Grade Vapor Barrier B. Related Sections: 1.02
More informationA. Section includes cast-in-place concrete, including reinforcement, concrete materials, mixture design, placement procedures, and finishes.
SECTION 033053 - CONCRETE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationA-9,250 Parking Structure Resurfacing Cement Look
A-9,250 Page 1 A-9,250 Parking Structure Resurfacing Cement Look Description This specification includes the repair and resurfacing methods used when applying Americrete products over cracked, spalled,
More informationSealing slurry system component of the KÖSTER KD System. approx. 15 min. approx. 20 sec. 2-3 hours. up to 7 bar (negative side)
Technical Data Sheet W 211 Issued: 2015-05-05 Sealing slurry system component of the Features The environmentally friendly stops active water ingress and safely seals off pressurized water from the negative
More informationKOSTER AMERICAN CORPORATION
Section 09699 PART 1 GENERAL Water Vapor Emission Control Systems 1.1 RELATED DOCUMENTS A. Drawings, documents, and general provisions of the Contract, including, but not necessarily limited to, General
More informationR3 Cementitious Pore Sealer and Levelling Mortar
Product Data Sheet Edition 15 June 2010 Identification no: 02 03 02 05 001 0 000042 (Template for local translation, only for internal use) Sika MonoTop -723 N R3 Cementitious Pore Sealer and Levelling
More informationMETHOD STATEMENT. BluSeal Tekflex EXTERNAL CEMENT LATEX MEMBRANE
BluSeal Tekflex EXTERNAL CEMENT LATEX MEMBRANE CONTENTS For the installation and quality control of BluSeal Tekflex External Cement Latex Membrane 1.0. GENERAL....................................................................
More informationSECTION TEXTURED COATINGS. A. Section includes textured coating for tilt-up panels.
SECTION 09910 TEXTURED COATINGS PART 1 GENERAL 1.01 SUMMARY A. Section includes textured coating for tilt-up panels. 1.02 REFERENCES A. Federal Specification TT-C-555B., Type I and II, GSA Exception. B.
More informationNEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE
NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE What is negative side waterproofing? A typical case of negative side waterproofing is when water comes through the walls of a basement and the
More informationNEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE
NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE What is negative side waterproofing? Why use KÖSTER waterproofing systems? A typical case of negative side waterproofing is when water comes
More informationWaterproofing Systems. Cementitious.
Construction Joint 2 coats Triton TT55 + TTME OR 2 coats @ 0.75 kg/m² per coat Construction Joint 2 coats Triton TT55 OR 1 coat @ 1 kg/m² Screed Reinforced Concrete Waterproofing Systems Cementitious n
More informationA. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.
SECTION 03 01 30 MAINTENANCE OF CAST-IN-PLACE CONCRETE SECTION 03 01 40 MAINTENANCE OF PRECAST CONCRETE SECTION 03 01 50 MAINTENANCE OF CAST DECKS AND UNDERLAYMENT SECTION 03 01 60 MAINTENANCE OF GROUTING
More informationSKATE ON LAYKOLD Specification
Acrylic Sport & Recreational Surfaces SKATE ON LAYKOLD Specification PART 1 GENERAL 1.1 DESCRIPTION Scope: This guide specification covers the construction and installation for the SKATE ON LAYKOLD inline
More informationSECTION MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS
SECTION 09699 MOISTURE RESISTANT/WATER-PROOF FLOORING ADHESIVE FOR CONCRETE SLABS PART 1 GENERAL 1.1 SECTION INCLUDES A. Testing and application of systems for the reduction of moisture resistant or water-proof
More informationNEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE
NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE What is negative side waterproofing? A typical case of negative side waterproofing is when water comes through the walls of a basement and the
More informationSECTION CAST-IN-PLACE CONCRETE
McClellan Blakemore Architects New Warehouse Facility for SECTION 03300 CAST-IN-PLACE CONCRETE PART 1 GENERAL 1.01 SECTION INCLUDES A. Concrete formwork. B. Floors and slabs on grade. C. Concrete floor
More informationUNIQUE. Product Description. Recommended Uses. For Best Results be between 55ºFF and 75ºF. the material. holes. masonry walls. cracks and holes in
DATA SHEET Product Description UNIQUE Water Stop is hydraulic cement blended with proprietary ingredients. Recommended Uses Use to instantly stop running water or seepagee through holes or cracks in concrete
More informationMATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1821 APRIL 2004 MATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS TABLE OF CONTENTS 1821.01 SCOPE 1821.02 REFERENCES
More information2. Division-4 Section for concrete unit masonry, and masonry restoration and cleaning.
SECTION 07180 WATER REPELLENTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 Specification Sections,
More informationBENCH MIX SPECIFICATIONS for REPAIR OF BENCHES IN MANHOLES WITH INERT LINES
Strong-Seal Systems BENCH MIX SPECIFICATIONS for REPAIR OF BENCHES IN MANHOLES WITH INERT LINES INTENT: To structurally restore and provide corrosion protection of exposed concrete benches, inverts and
More informationMS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES
MS-2A LINER SPECIFICATIONS: for STRUCTURAL REPAIR and SEALING of MANHOLES INTENT: To provide a system for reconstruction of concrete or masonry structures to stop inflow, infiltration, exfiltration, and
More informationSAN ANTONIO WATER SYSTEM 2013 REHABILITATION WORK ORDER CONSTRUCTION CONTRACT 4 SAWS Job No SAWS Solicitation No.
SAN ANTONIO WATER SYSTEM 2013 REHABILITATION WORK ORDER CONSTRUCTION CONTRACT 4 SAWS SAWS To Bidder of Record: ADDENDUM NO. 2 August 15, 2013 This addendum, applicable to work referenced above, is an amendment
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-07 11 13 (August 2011) Change 1-05/17 --------------------------- Preparing Activity: NAVFAC Superseding UFGS-07 11 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT SPECIFICATION EO-1007 REVISION 13 DECEMBER 2013 EFFECTIVE DATE DECEMBER 16,
More information1/16 Single Broadcast Polymer Flooring System
specification 1/16 Single Broadcast Polymer Flooring System Part 1 - GENERAL General Provisions A. Work to be covered by this section, under written specification or by drawing, shall comply with all provisions
More informationE. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.
DELTA -MS CLEAR Section 07 10 00 Dampproofing and Waterproofing PART 1 GENERAL 1.1 SECTION INCLUDES A. Below grade waterproofing and dampproofing. 1.2 RELATED SECTIONS A. Section 07 11 13 - Bituminous
More informationBENTONITE WATERPROOFING
SECTION 07 17 00 BENTONITE WATERPROOFING PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install bentonite waterproofing system where shown on the drawings, as specified herein, and as needed for a complete
More informationSection Fluid Applied Waterproofing
Section 07920 - Fluid Applied Waterproofing Part 1 - General 1.01 Summary A. This specification describes the injection of a crack or joint with infiltrating water with a low viscosity hydrophobic polyurethane
More information2.2 PRODUCT DATA XYPEX PRODUCT DATA
XYPEX PRODUCT DATA Concentrate... 39 Modified... 43 Admix C-500... 47 Admix C-1000... 51 Admix C-2000... 55 Concentrate DS-1... 59 Concentrate DS-2... 62 Patch n Plug... 66 Megamix I... 68 Megamix II...
More informationCRYSTALLIZATION CEMENTITIOUS WATERPROOFING
GREENSEAL 200 CRYSTALLIZATION CEMENTITIOUS WATERPROOFING DESCRIPTION ADVANTAGES Greenseal 200 is a concrete waterproofing system formulated from Portland cement, fine quartz sand and active chemicals.
More informationprofile-mix-plus, Page 1 of 8, Rev
Strong-Seal Profile Mix for reconstructing deteriorated structures to original dimensions, eliminating infiltration and providing structural restoration, corrosion protection and a smooth surface for application
More informationARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound
ARDEX GUIDE SPECIFICATION ARDEX CD Concrete Dressing and ARDEX CD FINE Concrete Dressing Polymer-Modified, Portland Cement-Based, Resurfacing Compound SECTION 03 01 30 MAINTENANCE OF CAST-IN-PLACE CONCRETE
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationCHATTANOOGA, TN Last Updated: 02/07/18. NOTE TO SPECIFIER: Be sure to obtain the latest version of this Guide Specification.
NOTE TO SPECIFIER: Be sure to obtain the latest version of this Guide Specification. This Guide Specification is not a completed document ready for use. It must be edited (i.e., deleting, adding, or modifying
More informationHIGH PERFORMANCE MIX SPECIFICATIONS
Strong-Seal Systems HIGH PERFORMANCE MIX SPECIFICATIONS INTENT: To provide a system for manhole reconstruction that stops inflow, infiltration, exfiltration, restores structural integrity and provides
More informationTEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING
SECTION 09960 - TEXTURED COATINGS Coating System Submittals Guide Specification TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING (SPLIT FACE OR SAND FINISH BLOCK) 1. TEX COTE 600, Textured Coating
More informationConstruction. 3-part cement and epoxy combination micro mortar for surface sealing. Product Description 1 1/5. Tests
Product Data Sheet Edition 29/11/2007 Identification no: 02 03 02 01 002 0 000002 SikaGard -720 EpoCem ZA 3-part cement and epoxy combination micro mortar for surface sealing Construction Product Description
More informationMadewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)
Madewell Products Corporation December 2014 7561 Industrial Court Alpharetta, GA 30004 Office: (770) 475-8199 Fax: (770) 475-8167 PART 1 GENERAL Product Guide Specification SECTION 03935 SPRAYABLE MICROSILICA
More informationSECTION MODIFIED BITUMINOUS SHEET WATERPROOFING
SECTION 07 13 52 MODIFIED BITUMINOUS SHEET WATERPROOFING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section
More informationSECTION mil thickness COLD FLUID-APPLIED WATERPROOFING
SECTION 07 14 16 CCW-MIRASEAL @ 120 mil thickness COLD FLUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationMDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls
MicroTex Eggshell Micro-Textured Ceramic Coating for Walls Specification Guide 95: 9770 Special Wall Finishes 88: 9800 Special Coatings Part 1 General 1.01 SUMMARY A. This section specifies the furnishing
More informationThe versatility and effectiveness of the Penetron. System have been demonstrated across a wide spectrum
ICS/PENETRON INTERNATIONAL LTD. is recognized as an international leader in the field of concrete waterproofing, protection, and repair. Over the past 20 years the Penetron family of products has established
More informationMATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 1821 NOVEMBER 2015 MATERIAL SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS TABLE OF CONTENTS 1821.01 SCOPE 1821.02 REFERENCES 1821.03 DEFINITIONS
More informationSECTION SPRAY FOAM INSULATION
SECTION 07 21 29 SPRAY FOAM INSULATION PART 1 GENERAL 1.1 SECTION INCLUDES A. Spray-in-place, light-density, semi-rigid, open-cell polyurethane foam insulation in assemblies indicated on the Drawings,
More informationSECTION STRUCTURE MOUNT RAILING SYSTEM
SECTION 05520 STRUCTURE MOUNT RAILING SYSTEM Peak Fall Protection specializes in the design, engineering, fabrication, installation, and certification of fall protection safety systems. Our team of safety
More informationMILANO WATER TREATMENT PLANT
ICS PENETRON INTERNATIONAL 45 Research Way, Suite 203 East Setauket, NY 11733 +1(631) 941-9700 info@penetron.com DESCRIPTION: In 1972, the Milan municipality committee approved the construction of a series
More informationCARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS
CARLISLE DECK COATING INSTALLATION OVER EXISTING POLYURETHANE COATINGS 1. GENERAL A. When coating over existing coatings, Carlisle can not assume responsibility for the adhesion of the existing coating,
More informationEN R4 High Strength High Build Concrete Repair Mortar
Product Data Sheet Edition 28th February 2018 Sika MonoTop-612 N EN 1504-3 R4 High Strength High Build Concrete Repair Mortar Construction Product Description Sika MonoTop-612 N is a cement-based, one
More informationCONCRETE REPAIR SITE HANDBOOK Hand Placed and Spray Applications
CONCRETE REPAIR SITE HANDBOOK Hand Placed and Spray Applications CONCRETE REPAIR SITE HANDBOOK Hand Placed and Spray application Sika MonoTop - pore sealer/ smoothing mortars Sika MonoTop - repair and
More informationNeoproof Polyurea R. Technical Characteristics. Description of the product. Applications
Description of the product Applications Neoproof Polyurea R is a highly durable, 2 component brushable polyurea, waterproofing coating for roofs, when mechanical durability and outstanding waterproofing
More informationPlanitop Smooth & Repair
Planitop Smooth & Repair R2-CLASS RAPID-SETTING CEMENTITIOUS MORTAR FOR REPAIRING AND SMOOTHING CONCRETE C.P. MK690930 (GB) 10/14 product for smoothing and repairing Just1 concrete surfaces Planitop Smooth
More informationA. Drawings and general provisions of the contract, including General and Supplementary Conditions, apply to this section.
Product Specification for: Rapid Set DOT Repair Mix SECTION 03 01 30 MAINTENANCE OF CAST-IN-PLACE CONCRETE SECTION 03 01 40 MAINTENANCE OF PRECAST CONCRETE SECTION 03 01 50 MAINTENANCE OF CAST DECKS AND
More informationPacific Polymers Elasto-Mat D&G Guide Specification
1 07141-1 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141 FLUID APPLIED WATERPROOFING 2 07141-2 August 2016 Pacific Polymers Elasto-Mat D&G Guide Specification SECTION 07141
More informationS Pene- Krete (Spray- Applied)
S- 1300 Pene- Krete (Spray- Applied) S- 1400 Pene- Krete Additive S- 1300 Pene- Krete Spray Applied S- 1300 Pene- Krete is a topically- applied densifier that is sprayed on to the surface. It provides
More information4.16. APPLICATION INSTRUCTIONS Construction Joints & Details
APPLICATION INSTRUCTIONS Construction Joints & Details 4.16 Krystol Waterstop System DESCRIPTION The Krystol Waterstop System is used to permanently waterproof concrete construction joints. It is installed
More informationList walls, planters, etc.., to which the anti-graffiti coating will be applied. Delete this note from the Contract Specifications.
X0321865 ANTI-GRAFFITI PROTECTION SYSTEM Effective: June 7, 2011 Revised: March 3, 2016 Description: This work shall consist of furnishing, and applying an anti-graffiti coating on all exposed faces of
More informationUFGS (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-07 16 19 (January 2007) ---------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-07 16 19 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More information1.1 Related Work Specified in Other Sections (Delete if Not Applicable):
NOTE TO SPECIFIER: Concrete Resurfacing (Broom Finish) System provides an economical alternative to the removal and replacement of existing concrete. This system creates a flexible and durable finish that
More informationSECTION MISCELLANEOUS CAST-IN-PLACE CONCRETE
SECTION 033053- MISCELLANEOUS CAST-IN-PLACE CONCRETE PART 1- GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationSetting holding down bolts Floor screeds Bedding blocks Stone and bricks In contact with potable water Fine moulding.
PRODUCT SHEET NATCEM 35 Description NATCEM 35 is a fast setting and fast curing mortar with a rapid strength gain that is resistant to chloride penetration, consisting of a blend of NATCEM Potable Water
More informationBeverly Vista School Deck Waterproofing. Bid Number16-17/100 SECTION TRAFFIC COATINGS
Beverly Vista School Deck Waterproofing Bid Number16-17/100 SECTION 07 18 00 TRAFFIC COATINGS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Preparation and examination of substrates to receive epoxy primer
More information