LED HANDRAIL For years, designers have been searching for an ADA compliant handrail that delivers ANSI compliant illuminance levels.

Size: px
Start display at page:

Download "LED HANDRAIL For years, designers have been searching for an ADA compliant handrail that delivers ANSI compliant illuminance levels."

Transcription

1 LED HANDRAIL For years, designers have been searching for an ADA compliant handrail that delivers ANSI compliant illuminance levels. luxrail

2 LED HANDRAIL luxrail TM LED HANDRAIL luxrail TM Lake Forest High School Designer: Perkins & Will luxrail grab bar 345 Park Avenue Designer: Jaros Baum & Bolles BART Train Station Eden Roc Hotel Fountain Square Park Designer: Tillett Lighting Design 401 E Michigan Designer: Gary Steffy Lighting Design Photographer: Carr Cialdella Photography 345 Park Avenue Designer: Jaros Baum & Bolles luxrailtm luxrail is an LED-based illuminated handrail. This energy efficient, sustainable solution finally addresses the building industry s need for an ADA compliant handrail that produces ANSI required illumination levels for both interior and exterior stairs, ramps and pedestrian walkways. Rio Hondo Pedestrian Bridge Designer: Steven Ehrlich Architects Photographer: Manuel Jaramillo 36 io Lighting 1100 Busch Parkway Buffalo Grove, IL T F E info@iolighting.com W iolighting.com

3 luxrailtm Application ANSI and ADA compliant, luxrail is an indoor/outdoor LED-based handrail that delivers functional illumination. Two intensities may be specified: standard output and high output. The standard light output version delivers illuminance levels appropriate for exterior applications (2 footcandles at grade) as well as for dark interior environments with low ambient illumination levels (e.g., themed environments, theatres and residential areas). The high output version delivers illuminance levels applicable to interior environments providing in excess of 10 footcandles along the path of egress (ANSI required for stair treads). Independent photometric test reports and IES Format data are available at luxrail s standard handrail gripping surfaces are circular in cross section and meet 2004 ADAAG (Americans with Disability Act Accessibility Guidelines). Patented optical assemblies deliver 10, 45 and 65 beam spreads. The 45 and 65 beam patterns are most suitable for illuminating pathways, while the 10 beam spread offers accent lighting for optional glass or stainless steel cable railing infills. Reference page 44 of this catalog for information regarding infill options. io ensures that each LED is provided thermal and electrical management properties in accordance with the LED manufacturers recommendations. Projected average rated life is 50,000 hours at 70% of lamp lumen output. Contact factory for IES LM-80 compliance. To ensure proper performance, architectural details should allow for ventilation and air flow around the fixture. Ambient temperature surrounding the fixture shall not exceed 120 F (48.9 C). Light Output Two luminous intensities are available for white light. All values below are initial lumens per foot. IES LM-79 format files may be obtained from the factory or downloaded from K White: 3000K White: 5000K White: Standard Output 48 lms/ft 48 lms/ft 63 lms/ft For Amber only. High Output 180 lms/ft 180 lms/ft 240 lms/ft Light Output / Distributions BEAM SPREAD OPTIONS WALL MOUNT DETAILS* 22 AWG, 300v power cord Power cord for secondary feed. Wire gauge as required for remote driver. luxrail light fixture Snap-Cover Flange Snap Base Wireway 22 AWG, 300v power cord Locking Bracket Mount To remote driver Tube Extension, as needed for conduit connection * Wall mounted luxrail may be mounted to new or existing guardrail (by others). Post and wall bracket spacing must be determined by a licensed architect or structural engineer. LIGHT OUTPUT - 65 Degree warm white 36" (.9m) ' 4' 3' 2' 1' 5' 4' 3' 1' 2' 1' 3' 4' 5' 1' 2' 3' 4' 5' 5' 4' 3' 2' 1' 1' 2' 3' 4' 5' POST MOUNT APPLICATION Wildlife Friendly Fixtures 60" (1.5m) Note: 4' to 5' typical 42" (1.06m) " (0.86m) IDA s Fixture Seal of Approval Dimensions 1.66" (42.2mm) Lighting Facts LED Product 6PRA-7ZBT8B 0.03.I.3KHO Outdoor path lights 1.90" (48.3mm) io luxrail 65, 3KHO (Bright White) Label references 30" luxrail fixture with a 65 beam spread in High Output 3000K. Lighting Facts for additional beam spreads and light output levels may be obtained from io Lighting. Construction luxrail may be post mounted or wall mounted. Mounting hardware (post or wall) is typically required up to 5' O.C., depending on the handrail alloy. Final post and wall bracket spacing must be determined by a licensed architect or structural engineer. io can provide engineering upon request. luxrail is available in stainless steel and aluminum. grab bars are available in aluminum only. The lighting fixture component of the luxrail is a stand alone unit and is available in incremental nominal lengths that range from 6" to 60". Vandal resistant access chamber allows units to be removed for maintenance purposes. All handrail component parts are engineered for quick installation. Field welding or cutting is typically not required. All parts are prefabricated to field dimensions and are assembled in the field with mechanical connection or epoxy. Contact io Lighting for recommended handrail installers. The light fixture s housing is made of a light weight, yet durable aluminum, providing the recommended heat sink requirements for the LEDs. Housing, patented optical assembly and stainless steel end caps are bonded to prevent water infiltration. Electrical luxrail houses a low voltage LED-based light fixture that is integrated into the underside of the handrail. 24 volt 96 watt power supplies are provided as a standard. For detailed information regarding daisy chain limitations, remote distance limitations, power supply options, and dimming options consult the io website, the io catalog (pages ) or an io representative. Dimming modules must be specified separately. For detailed information, see page 98 of this brochure or download the power supply specification sheet from Power Consumption Standard Output: 1.44 w/ft High Output: 7.62 w/ft Power consumption does not include power supply losses. Footnotes Order Code Mounting / Infill Options PM (post mounted) 0 06 WM (wall mount intermediate) Glass infill (glass provided by others) io PRODUCT FAMILY 06 luxrail 2. ALLOY / FINISH SSS Stainless steel satin SSP Stainless steel polished CAA Clear anodized aluminum (7) 3. SIZE " O.D. (1 1 4" pipe size) (7) (available for SS & CAA) " O.D. (1 1 2" pipe size) (available for SS & CAA) 4. MOUNTING PM Post mounted (7) WM Wall or guard rail mounted 5. INFILL AC Stainless steel cable (5) GL Glass (provided by others) C Custom NR Not required 6. LIGHT DISTRIBUTION Degree Degree Degree NI Handrail only (not illuminated) 1. Power Supply Specification Sheet may be downloaded from 2. Each handrail application will be custom to accommodate varying field conditions and design requirements. Shop drawings will be required to manage specifics of each handrail section. 3. White light variance between LEDs within a single fixture will not exceed ANSI Binning Standards. 4. Only available in 7.6 w/ft. 5. Stainless Steel cable available for flat surfaces only. 6. Detailed elevation drawings of handrail section are required for quote. 7. grab bars available in aluminum only. 7. LIGHT COLOR 27K Warm White 3K Warm White (3) 5K Cool White (3)) 27KHO Warm White 3KHO Warm White (3) 5KHO Cool White (3) R Red (4) G Green (4) B Blue (4) A Amber (4) 8. LENGTH GB2 2' nominal (8) GB3 3' nominal (8) GB4 4' nominal (8) GB5 5' nominal (8) HR In Feet / Inches (provide overall length of each handrail section) (2)(6) Stainless steel cable infill (only available on flat surfaces) VOLTAGE / dimming 1 120v 2 277v 3 120v w/dim 4 277v w/dim 5 Other 10. SPECIFY driver / DIMMING (1) Note: If not specified otherwise, io will supply 96 watt drivers. Download Power Supply specification sheet from SSL Chromaticity Standard: ANSI C Target CCT & Color Nominal CCT Tolerance (K) White White White 2700K 3000K 5000K 2725 ± ± ± 283 For Metric Conversion 1" 1" 1' 25.4mm 2.54cm 0.3m

4 Wall Mount Handrail Options Stairs Stair handrail wall returns may be specified with a extension. io requires field verified horizontal and diagonal stair dimensions in order to generate shop drawings. Additional field dimensions may be required depending on the complexity of the handrail design. Post Mount Options Posts are chosen to match or complement your handrail selection. Posts are spaced between 4' and 5' on-center depending on specified size and alloy. Posts may be surface mounted or embedded below concrete surface and set with quick-setting grout by contractor. Base plates are optional. Surface Mounted Embedded Wall Return 1" (25mm) 13 16" (21mm) 41 2" (114mm) Cover Flange Slip Flange with or without set screw 3.25" (83mm) 6" (0.15m) Clear Hole for 3 8" bolts (9.6mm) Rocktite Ext. Wall Return 3.25" (83mm) 6" (0.15m) Diagonal Slope Elevation Change 31 4" diameter Bolt Circle (82.5mm) Flange Base Concrete 1 2" or 3 4" Conduit (13mm or 19mm) 10" (0.15m) Horizontal Ramps Ramp handrail wall returns may be specified with a extension. io requires field verified horizontal and diagonal ramp dimensions in order to generate shop drawings. Additional field dimensions may be required depending on the complexity of the handrail design. 401 E. Michigan Designer: Gary Steffy Lighting Design Photographer: Nelson Nave ADA Compliant Return Options Return to Walking Surface min 1 tread width min 345 Park Avenue Designer: Jaros Baum & Bolles Wall Return 3.25" (83mm) 6" (0.15m) Ext. Wall Return Return to Post Lake Forest High School Designer: Perkins & Will 3.25" (83mm) min 1 tread width min Diagonal Slope Elevation Change Horizontal Mississippi River Overlook Designer: HOK Eden Roc Hotel

5 Application Options grab bar may be customized to accommodate ADA lighting or aesthetic requirements. Submit concept sketches to io Lighting for design assistance. Custom luxrail grab bar lengths can be specified to accommodate all ADA Compliant applications Water Closets Bath Tubs Shower Stalls 36" min 27" max 36" min max 48" min 15" max Control Area Custom grab bar 33"-36" 33"-36" 9" 33"-36" 38" min 48" max Back Wall With Seat at Head of Tub 54" min 54" min max 24" min 15" max 24" min Standard grab bar 17"-19" 19" min 33"-36" 33"-36" 9" 33"-36" Side Wall Back Custom grab bar Length Options Standard grab bar lengths may be ordered available in nominal lengths of 2', 3', 4', and 5'. Handrail Dimensions The following references are taken from the 2004 Americans with Disabilities Act Accessibility Guidelines Circular Cross Section Handrail gripping surfaces with a circular cross section shall have an outside diameter of 11 4" (32mm) minimum and 2" (51mm) maximum. Railings shown are not to scale. Capital One Designer: Oglesby Holtman Design Photographer: Dan Kohnen

6 Electrical luxrail integrates a low voltage LED-based linear light fixture within the handrail. luxrail requires a power supply to transform and regulate the voltage. This power supply is called a driver. The luxrail requires that the 24v driver be remotely located. The driver must be housed in an enclosure that is rated for use in both interior and exterior applications. luxrail utilizes a compact electronic driver which is protected against open circuit, short circuit, overload and overheating conditions. It is UL recognized and FCC compliant. Light Backing Pad Secondary Feed Routed through Wall Bracket Feed Termination Light Mounting Clip Slotted Tube Insert 22 AWG, 300 Volt Power Cord io Luxrail LED Fixture Wall Mount Bracket Wire Nut Connections within Wireway Transition Sleeve 200-Watt Driver IO PART#: DR2ØØAM 96-Watt Driver With Dimming Option IO PART#: DR96MGD WithOUT Dimming Option IO PART#: DR96MGND Key Features Recommended for long continuous runs Suitable for dry, damp and wet locations Built in wiring compartments for easy installation Built in EMI Filter for low noise Key Features Integrated dimming available Suitable for dry, damp and wet locations Locations with an adequate end plate and connectors Built in wiring compartments for easy installation Specifications Location: Wet IP65 Output Voltage: 24v DC Output Power: 200w Input Voltage: 90 to 264 VAC Frequency: 47 to 63 HZ Ambient Temp: -20 C to +50 C Weight: 6.61 lbs Dimming: Yes w/ 250IOXFDIM. Requires one dimming module for each channel. Specifications Location: Wet IP66 Output Voltage: 24v DC Output Power: 96w Input Voltage: 100 to 277 VAC Frequency: 47 to 63 HZ Ambient Temp: -30 C to +70 C Dimming: Integrated Available Driver with Enclosure Infill Options When a handrail is installed on ramps, stairs or landings 30" above finished floor it is referred to as a guardrail. Handrails provide guidance, while guardrails prevent accidental falls. Guardrails have opening limitations. The most common requirement is that no opening be large enough to allow a4" sphere to pass. luxrail has two infill options to address this requirement: stainless steel cable and glass. Stainless steel cable and all required hardware are supplied with system. For glass infill option, panel clips are supplied with system; glass is supplied by others. 60-Watt Driver With Dimming Option IO PART#: DR6ØMGD WithOUT Dimming Option IO PART#: DR6ØMGND Key Features Integrated dimming available Suitable for dry, damp and wet locations Locations with an adequate end plate and connectors Built in wiring compartments for easy installation Specifications Location: Wet IP66 Output Voltage: 24v DC Output Power: 60w Input Voltage: 90 to 264 VAC Frequency: 47 to 63 HZ Ambient Temp: -30 C to +70 C Dimming: Integrated Available Stainless steel cable infill Stainless steel cable railing system integrates all cable hardware inside the end posts, making it virtually invisible. The cable railing system may only be used with the stainless steel railing frame. Stainless steel railing hardware can be factory swaged or field swaged by the installer. Cable infill is only available for flat surfaces. io Studio Glass infill Panel clips are used to support 1 4" or 1 2" tempered glass infill panels. Glass is provided by others. 2 1 /8" (54mm) Rubber O-ring 2 1 /4" (57mm) Glass Supported Pin Install through predrilled hole in the glass (optional) 20-Watt Driver IO PART#: DR2ØOS Key Features Small enclosure size Light weight, low profile Short circuit and overload protection Low power supply losses Specifications Location: Dry Output Voltage: 24v DC Output Power: 20w Input Voltage: 120 to 240 VAC Frequency: 50 to 60 HZ Ambient Temp: -20 C to +50 C Weight:.21 lbs Dimming: Yes w/ 250IOXFDIM Note: See page 98 for more information or contact an io representative.

7 Code Details Accessibility Code References ICC: International Code Council BOCA: Building Officials Code Administration ICBO: International Conference of Building Officials SBCCI: Southern Building Code Congress IBC: IRC: International Building Code International Residential Code Prior to 2000, BOCA, SBCCI and ICBO each prepared their own model codes that were regionally applied. In 1999, these three organizations merged to form the International Code Council (ICC). In 2000, the ICC published the International Building Code (IBC) and the International Residential Code (IRC). The IRC and the IBC model codes have since been adopted by states throughout the U.S. Sustainability io Recommends Aluminum GREEN Aluminum is one of the most sustainable materials on earth. Making up 8% of the Earth s crust, Aluminum is one of the most plentiful elements and most preferred building material because it can be indefinitely recycled without loss of properties or quality. DURABLE Aluminum generates a protective oxide coating which makes it naturally corrosion resistant, weather proof and immune to harmful effects of UV rays. Requiring little to no maintenance, Aluminum does not absorb moisture and is saltwater resistant. It will not rust, rot, swell, warp, twist, split or crack. ROBUST Aluminum is about one-third the weight of steel yet its tensile strength is perfect for handrails, curtain walls, window frames, wall framing systems and solar shading. LEED Although recycled material percentages constantly change, approximately 25% of io s aluminum handrail comes from recycled pre-consumer aluminum. FINISH Aluminum can be anodized or painted in any color. Some surface finishes can offer increased durability and corrosion resistance. Consult io Lighting for details. Clear Anodized Aluminum Caprail ANSI Compliant Illumination Levels Illuminance Level Requirements IBC: 1 footcandle for means of egress for emergency lighting. IRC: Light level not specified. ANSI A117: Stairways shall have 10 footcandles measured at the center of the tread surface and on landing surfaces within 24" of step nosing. Accessibility Guidelines Two references: 1) ICC/ANSI A117.1: Accessible And Usable Buildings & Facilities 2) The Americans with Disabilities Act Accessibility Guidelines (ADAAG) Note: ADA is a civil rights law it is not a building code. However, the ADAAG has been incorporated into many state and local building codes. Handrails and Guardrails Handrails provide guidance Handrails are located between 34" and 38" above stair nosings or ramp surfaces and have dimensional limitations for graspability. In areas where children are the principal users (e.g., elementary schools), the ADAAG recommends a second set of handrails be located at 28" above stair nosings or ramp surfaces. Reference: IBC 2000, ANSI A117.1, ADAAG Guardrails prevent accidental falls Guardrails are generally required for ramps, stairs or landings above 30". The height will vary depending on local code. The IBC requires a guardrail to be 42" in height. If a 42" guardrail is called for on a stair or ramp, it will require a handrail at a height of between 34" and 38". The IRC requires 36" high guardrails for porches, balconies and raised floor surfaces. A guard s top rail does not have to meet the requirements for graspability if a handrail is in place. Rio Hondo Pedestrian Bridge Designer: Steven Ehrlich Architects Photographer: Manuel Jaramillo Capital One Designer: Oglesby Holtman Design Photographer: Dan Kohnen

8 The Specification Process luxrail crosses into two separate sections of the architectural specification both as handrail which is listed in the Miscellaneous Metals section and as lighting which is listed in the Electrical section. As such, it requires two different trades for installation: an experienced handrail installer and a licensed electrician. It is important that contractors understand that luxrail must be bid on and installed by two separate trades to ensure accurate labor estimates. On some projects, architects have created an entirely new and separate section of the specification package for luxrail, spelling out exactly how the bidding and installation need to be handled. When requesting a quote for luxrail, fully dimensioned plan and elevation drawings of each individual railing section are required. Stair and ramp elevations can be found in the Architectural details. Exterior railing locations and elevations are usually shown in the Landscape plans and details. The elevations illustrate the required style, size and features of each railing. The plan views show the location, length and quantity of rails needed. The lighting fixture schedule should also be provided as it lists the desired light output, color and distribution. From these project specific details a customized quotation is created. After an order is placed, detailed submittal drawings are prepared and sent to the customer for approval. The submittals must be reviewed for compliance with site conditions, conformance with lighting specification and fulfillment of the electrical power requirements. This may require review by several parties. The lead-time on luxrail fixtures begins once the signed approval drawings have been returned. Once approved, luxrail is custom fabricated to the exact project details and specifications as illustrated in the approvals. Submittals should be reviewed with three objectives in mind: 1. The handrail drawings must be reviewed for compliance to site conditions. Finished stair and ramp dimensions usually vary from the architectural plans. For this reason, actual field dimensions must be used when reviewing the submittals. This portion of the review is typically done by the handrail installer. Contact io Lighting for approved luxrail installers. 2. The LED fixture counts and run lengths must be reviewed to verify that adequate power is provided to each railing and that all remote driver restrictions have been met. This portion of the review is typically done by the electrical contractor. 3. The luxrail catalog code must be reviewed for compliance to the lighting specifications. The light output, beam spread and distribution should be verified. This portion of the review is typically done by the lighting designer. Elevation Drawings Submittal Drawings Completed Luxrail Project io has a dedicated team for luxrail projects. Let us help you from design through installation. Mississippi River Overlook Designer: HOK

9 Lake Forest High School Designer: Perkins & Will Eden Roc Hotel Mississippi River Overlook Designer: HOK 345 Park Avenue Designer: Jaros Baum & Bolles Fountain Square Park Designer: Tillett Lighting Design 401 E. Michigan Designer: Gary Steffy Lighting Design Photographer: Nelson Nave Lake Forest High School Designer: Perkins & Will The Pucci Residence Note: Complete custom application. Depot Landmark Building Designer: Gary Steffy Lighting Design Photographer: Nelson Nave Capital One Designer: Oglesby Holtman Design Photographer: Dan Kohnen io Studio Mississippi River Overlook Designer: HOK

Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX

Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX Building Codes Building Codes Prior to using any railing products, it is incumbent on designers, fabricators and installers to make

More information

Contemporary Railing Systems

Contemporary Railing Systems Contemporary Railing Systems GLASS, STAINLESS STEEL, CABLE, LED, CODES, STANDARDS, AND LEED The Wagner Companies is a Registered Provider with the American Institute of Architects Continuing Education

More information

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0238 Code Compliance Research Report CCRR-0238 Issue Date: 11-09-2016 Revision Date: 11-29-2018 Renewal Date: 11-09-2019 DIVISION: 05 00 00 METALS Section: 05 52 00 Metal Railings CPG Building Products LLC

More information

Aluminum Component Pipe Railings

Aluminum Component Pipe Railings 1 SECTION 05 7360 ALUMINUM COMPONENT PIPE RAILINGS PART 1 GENERAL 1.01 SECTION INCLUDES A. Aluminum component pipe handrails and railings. 1.02 RELATED REQUIREMENTS A. Section 02 9000: Landscaping: Installation

More information

Code Compliance Research Report CCRR-0238

Code Compliance Research Report CCRR-0238 Code Compliance Research Report CCRR-0238 Issued: 11-09-2016 Renewal Due: 11-09-2018 Revised: 11-10-2017 DIVISION: 05 00 00 METALS Section: 05 52 00 Metal Railings CPG Building Products LLC 894 Prairie

More information

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports. SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Handrails and guardrails B. Guardrails for hatches and openings. C. Safety barriers. D. Roof edge protection. 1.2 RELATED SECTIONS

More information

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Safety Railing Solutions

Safety Railing Solutions providing safety solutions worldwide Safety Railing Solutions 2009 Solutions to your railing problems simple to design and specify unrivaled technical support world wide availability honoree CSI 05520

More information

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE

More information

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Decorative Wire Rope Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in

More information

Trex Commercial Products page Metal Railing

Trex Commercial Products page Metal Railing SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post Rail (Glass). D. Tensiline Railings (Cable). E. Track Rail (Glass).

More information

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,

More information

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Post

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 10/13/2016 Issued: 12/17/2014 Visit www.ati-es.com for current status Revised: 10/30/2015 Page 1 of

More information

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,

More information

SECTION Permanent Grandstands PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION Permanent Grandstands PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 13125 Permanent Grandstands PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections,

More information

SECTION ROOF EDGE SAFETY RAILING SYSTEM

SECTION ROOF EDGE SAFETY RAILING SYSTEM SECTION 07720 ROOF EDGE SAFETY RAILING SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Provide and install freestanding KeeGuard Roof Edge Protection System, including pipe railings, uprights, bases, counterweights,

More information

4621 East 75 th Terr. Kansas City, MO Phone (816) l Fax (816) LiversBronze.com l

4621 East 75 th Terr. Kansas City, MO Phone (816) l Fax (816) LiversBronze.com l 4621 East 75 th Terr. Kansas City, MO 64132 Phone (816) 300 2828 l Fax (816) 300 0864 LiversBronze.com l Livers@LiversBronze.com SECTION 05 73 13 [ILLUME LED LIGHTED RAILING] [LIVERS BRONZE RAILING SYSTEM]

More information

Code Compliance Research Report CCRR-0187

Code Compliance Research Report CCRR-0187 Code Compliance Research Report CCRR-0187 Issue Date: 11-29-2012 Revision Date: 07-24-2018 Renewal Date: 02-28-2019 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 63 00 Plastic Railings REPORT

More information

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL ALUMINUM RAILING SECTION 05730 ORNAMENTAL ALUMINUM RAILING PART 1 GENERAL 1.1 SECTION INCLUDES A. Aluminum Pipe Railing 1.2 RELATED SECTIONS A. Section 03300 Cast-In-Place Concrete: Placement of sleeves cast in concrete.

More information

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing The following specification has been developed by: Superior Aluminum Products 555 East Main Street Russia, Ohio 45363-0430 to assist Architects and Designers in the specification of Non Welded Concealed

More information

Manufactured decking (composite) may be used when approved by the building department

Manufactured decking (composite) may be used when approved by the building department DO YOU THINK YOU MIGHT ENCLOSE YOUR DECK IN THE FUTURE? Deck plans are approved based on the assumption that the deck will be used only as a deck for the life of the structure. Because there are so many

More information

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0163 Code Compliance Research Report CCRR-0163 Issue Date: 04-13-2011 Revision Date: 10-03-2018 Renewal Date: 10-13-2019 DIVISION: 05 00 00 - METALS Section: 05 52 00 Metal Railings REPORT HOLDER: Digger Specialties,

More information

Code Compliance Research Report CCRR-0163

Code Compliance Research Report CCRR-0163 Code Compliance Research Report CCRR-0163 Issue Date: 10-19-2016 Renewal Date: 10-13-2017 Revision Date: 03-30-2017 DIVISION: 05 00 00 - METALS Section: 05 52 00 Metal Railings DIGGER SPECIALTIES, INC.

More information

Safety Railing Solutions

Safety Railing Solutions providing safety solutions worldwide Safety Railing Solutions Solutions to your railing problems simple to design and specify unrivaled technical support world wide availability CSI 05520 January 2009

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products.

SECTION ORNAMENTAL ALUMINUM RAILING. ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. SECTION 05720 ORNAMENTAL ALUMINUM RAILING ** NOTE TO SPECIFIER ** Superior Aluminum Products, Inc.; Ornamental aluminum railing products. This section is based on the products of Superior Aluminum Products,

More information

Code Compliance Research Report CCRR-0223

Code Compliance Research Report CCRR-0223 Code Compliance Research Report CCRR-0223 Issued: 06-30-2015 Renewal Due: 06-30-2018 Revised: 12-20-2017 DIVISION: 05 50 00 - Metal Fabrications Section: 05 52 00 - Metal Railings REPORT HOLDER: Ultra

More information

LAPEYRE STAIR PRODUCT LINE

LAPEYRE STAIR PRODUCT LINE LAPEYRE STAIR PRODUCT LINE Continuously Elevating Standards lapeyrestair.com Leave the stairs to the experts Lapeyre Stair provides a complete outsource solution for stairs with in-house resouces and over

More information

3 WALL ASYMMETRIC W W W. L U M E N W E R X. C O M

3 WALL ASYMMETRIC W W W. L U M E N W E R X. C O M DESCRIPTION PROJECT: Via Wet offers architectural lighting for wet locations in both exterior and interior applications. With a simple TYPE: ¾" high by 4½" wide profile of NOTES: extruded aluminum, Via

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 05/16/2016 Issued: 06/29/2015 Visit www.ati-es.com for current status Page 1 of 9 CPG Building Products

More information

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System SECTION 05 5200 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install stainless steel railings and components. 1.02 REFERENCE

More information

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System SECTION 05720 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install supported glass stainless steel railings, glass

More information

Park Hill School District South HS Football Venue & Park Hill HS Soccer Venue

Park Hill School District South HS Football Venue & Park Hill HS Soccer Venue SECTION 03 26 14 Permanent Grandstands- Factory computerized welded decking system PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of Contract, including General and Supplementary

More information

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS SECTION 05520 ALUMINUM HANDRAIL SYSTEMS PART 1 - GENERAL 1.01 SUMMARY A. Section includes aluminum handrails and railings. B. Related Work: 1. Section 03300 - Cast-in-Place Concrete C. References: 1. American

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 08/26/2012 Issued: 08/26/2011 Visit www.ati-es.com for current status Page 1 of 19 UFP Ventures II,

More information

Section Rigid PVC Railings and Balustrades

Section Rigid PVC Railings and Balustrades Section 06 63 00 Rigid PVC Railings and Balustrades PART 1 GENERAL 1.1 SECTION INCLUDES A. Section 06 Fairway Architectural Railing Solutions Rigid PVC Railing 1.2 RELATED SECTIONS A. Section 06-4300 -

More information

Code Compliance Research Report CCRR-0171

Code Compliance Research Report CCRR-0171 Code Compliance Research Report CCRR-0171 Issue Date: 08-26-2011 Revision Date: 06-20-2018 Renewal Date: 06-30-2019 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 63 00 Plastic Railings REPORT

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125 Subject to Renewal: 05/16/2018 Issued: 05/24/2017 Visit www.ati-es.com for current status Page 1 of 9 CPG Building

More information

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec SECTION 05720 ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec PART 1 - GENERAL 1.01 WORK INCLUDED A. Furnish and install [aluminum] railings and components. 1.02 REFERENCE A. American

More information

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS SECTION 05720 ARCHITECTURAL GLASS HANDRAIL AND RAILINGS PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and install [aluminum] railings and components. 1.02 REFERENCE A. American Architectural Manufacturers

More information

SECTION LIGHTING. A. Section Basic Electrical Materials and Methods

SECTION LIGHTING. A. Section Basic Electrical Materials and Methods SECTION 16500 LIGHTING PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide lighting fixtures of sizes, types and ratings as indicated; complete with, but not necessarily limited to, housings, lamps, lamp holders,

More information

RECESSED - WITH ACCENT OPTION ONLY. Extended 3 1/32

RECESSED - WITH ACCENT OPTION ONLY. Extended 3 1/32 Project Type Notes Linear option shown Kit option shown PERFORMANCE Semi-Recessed Extended Pivoted Semi-Recessed 1 3/4 Extended 1 3/4 Beam Spread 24º 36º 60º CBCP 2287 cd 796 cd 446 cd 3 1/32 3 1/32 1/2

More information

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Glenlake Modular Railing System

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Glenlake Modular Railing System SECTION 05 5200 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Glenlake Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install post supported stainless steel railings and components.

More information

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

MASTERSPEC - SHORT FORM. B. See Division 5 Section Metal Stairs for steel tube railings associated with metal stairs. SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 05 5117 ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION ALTERNATING TREAD STEEL STAIRS SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this

More information

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System SECTION 05720 ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install supported glass stainless steel railings, glass

More information

Specialty Vinyl Systems

Specialty Vinyl Systems R www.fairwayvinyl.com Specialty Vinyl Systems Fairway s Railing Systems have been tested to the prevailing ICC (International Code Counsel) standards and requirements for both IRC-2006 (Residential) and

More information

SECTION ORNAMENTAL ALUMINUM RAILINGS PART 1 - GENERAL 1.01 SUMMARY

SECTION ORNAMENTAL ALUMINUM RAILINGS PART 1 - GENERAL 1.01 SUMMARY 3-PART SPEC ORNAMENTAL ALUMINUM RAILINGS PART 1 - GENERAL 1.01 SUMMARY SECTION 05720 A. Section Includes: a. Solutions aluminum extruded shape top rail, square or round balustrade & rectangular bottom

More information

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section ) 8-1200. International Residential Code. ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section 6-9-40) NOTE-This article

More information

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213 Code Compliance Research Report CCRR-0213 Issue Date: 08-04-2017 Renewal Date: 08-01-2018 DIVISION: 05 50 00 METAL FABRICATIONS Section: 05 52 00 Metal Railings REPORT HOLDER: Key Link Fencing & Railing,

More information

Code Compliance Research Report CCRR-0262

Code Compliance Research Report CCRR-0262 Code Compliance Research Report CCRR-0262 Issued: 12-29-2017 Renewal Due: 12-29-2018 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 03 11 Plastic Railings REPORT HOLDER: HB&G BUILDING PRODUCTS,

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125 Subject to Renewal: 02/21/2018 Issued: 02/28/2017 Visit www.ati-es.com for current status Page 1 of 7 Trex Company,

More information

Code Compliance Research Report CCRR-0213

Code Compliance Research Report CCRR-0213 Code Compliance Research Report CCRR-0213 Issue Date: 08-01-2014 Revision Date: 08-28-2018 Renewal Date: 08-01-2019 DIVISION: 05 50 00 METAL FABRICATIONS Section: 05 52 00 Metal Railings REPORT HOLDER:

More information

Quick Facts LED AREA FIXTURES. Modern bollard produces 360 spread without glare. Aluminum construction. RGBW capable with ZDClink systems.

Quick Facts LED AREA FIXTURES. Modern bollard produces 360 spread without glare. Aluminum construction. RGBW capable with ZDClink systems. TYPE CATALOG # PROJECT NOTES LED AREA FIXTURES 2.5" 6.4 cm apillar Modern bollard produces 36 spread without glare. Aluminum construction. RGBW capable with ZDClink systems. Quick Facts n Die-cast aluminum

More information

ATI-ES Code Compliance Research Report

ATI-ES Code Compliance Research Report PCA-125 Subject to Renewal: 06/23/2018 Issued: 06/28/2017 Visit www.ati-es.com for current status Page 1 of 17 CPG Building Products LLC 894 Prairie Avenue Wilmington, Ohio 45177 (866) 862-7832 www.cpgbp.com

More information

Garda. Illuminated handrail

Garda. Illuminated handrail Garda Illuminated handrail BSkyB Headquarters, London Contents Materials 4 Colours 6 Modules 8 Mounting & infills 10 A full turnkey solution 12 On location: River Ettrick, Selkirk 14 St James s Place,

More information

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Classic Railings (Picket). B. GridGuard Railings (Mesh). C. Invisirail

More information

SECTION DECORATIVE METAL RAILINGS

SECTION DECORATIVE METAL RAILINGS SECTION 05 73 00 DECORATIVE METAL RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Vertical Stainless Steel Cable Railing System. B. Horizontal Stainless Steel Cable Railing System. 1.2 RELATED SECTIONS

More information

A. Atlantic Railing Series with Mushroom Top and Square Pickets

A. Atlantic Railing Series with Mushroom Top and Square Pickets 100 Series-A1-A10 PART 1 General 1.1 SECTION INCLUDES A. Atlantic Railing Series with Mushroom Top and Square Pickets 1.2 RELATED SECTIONS A. Section 05510-Metal Stairs: Metal Handrails other than those

More information

DIVISION 5 METALS COLD FORMED METAL FRAMING Structural Metal Stud Framing

DIVISION 5 METALS COLD FORMED METAL FRAMING Structural Metal Stud Framing 05 40 00 COLD FORMED METAL FRAMING 05 41 00 Structural Metal Stud Framing 05 50 00 METAL FABRICATIONS 05 51 00 Metal Stairs 05 51 13 Metal Pan Stairs 05 52 00 Metal Railings 05 52 13 Pipe and Tube Railings

More information

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING 7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes

More information

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016 February 2016 Residential Deck Safety, Construction and Repair Juneau Permit Center, 4 th Floor Marine View Center,(907)586-0770 This handout is designed to help you build your deck to comply with the

More information

A. This Section includes the following: 1. Aluminum pipe and tube handrails and railings.

A. This Section includes the following: 1. Aluminum pipe and tube handrails and railings. SECTION 05521 - PIPE AND TUBE RAILINGS PART 1 - GENERAL.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0100

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0100 ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 Subject to Renewal: 06/27/09 Date Issued: 06/27/07 Visit for current status Page 1 of 5 Mid Atlantic Vinyl Products, Inc. 5109 Commonwealth

More information

Code Compliance Research Report CCRR-0194

Code Compliance Research Report CCRR-0194 Code Compliance Research Report CCRR-0194 Issued: 09-16-2013 Renewal Due: 09-16-2018 Revised: 10-12-2017 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 05 23 Wood, Plastic, and Composite

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES, CUTOFF TYPE

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES, CUTOFF TYPE STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES, CUTOFF TYPE N.J. Specification No. Effective Date: July 1, 2001 New Jersey

More information

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002 SECTION 07 42 13 ALUMINUM PLATE PANEL SYSTEM ALPLY Insulated Panels Alply TECH WALL Aluminum Plate System 2002 PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Preformed Aluminum Plate System for Screen wall

More information

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware. 1 SECTION 08 4210 ALL GLASS ENTRANCES PART 1 - GENERAL 1.01 SUMMARY A. This section includes: 1. Vestibule doors matching entrance doors. 2. Sidelites. B. Related work in other sections: 1. Lock cylinders

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING 7160 Krick Rd., Walton Hills, OH 44146 800-321-3827 - Tel 440-439-8650 - Fax 440-439-6889 SECTION 12 48 16 ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING PART 1. GENERAL 1.01 SUMMARY: This section includes

More information

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication

More information

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011. DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:

More information

DECORATIVE METAL RAILINGS

DECORATIVE METAL RAILINGS SECTION 057300 - DECORATIVE METAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Steel and iron decorative railings. 1.2 PERFORMANCE REQUIREMENTS A. Delegated Design: Design railings, including

More information

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 48 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

Section Permanent Beam Grandstands

Section Permanent Beam Grandstands Section 13 34 16 Permanent Beam Grandstands Part 1 GENERAL.1 Section Includes.1 Design, fabrication, engineering and installation of permanent beam grandstand assembly, including the following:.1 Foundations.2

More information

Code Compliance Research Report CCRR-0114

Code Compliance Research Report CCRR-0114 Code Compliance Research Report CCRR-0114 Issue Date: 08-31-2007 Revision Date: 06-20-2018 Renewal Date: 06-23-2019 DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES Section: 06 63 00 - Plastic Railings

More information

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section. SECTION - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

More information

Trex Commercial Products page Decorative Metal Railing

Trex Commercial Products page Decorative Metal Railing SECTION 05 73 00 DECORATIVE METAL RAILINGS TREX COMMERCIAL PRODUCTS Monaco Modular Railing System PART 1 GENERAL 1.01 WORK INCLUDED A. Furnish and/or install supported glass stainless steel railings, glass

More information

ATI-ES Code Compliance Research Report

ATI-ES Code Compliance Research Report PCA-125 Subject to Renewal: 06/23/2016 Issued: 07/13/2015 Visit www.ati-es.com for current status Revised: 05/23/2016 Page 1 of 17 CPG Building Products LLC 894 Prairie Avenue Wilmington, Ohio 45177 (866)

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125 ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125 Subject to Renewal: 04/15/2017 Issued: 05/06/2016 Visit www.ati-es.com for current status Page 1 of 14 TAMKO Building

More information

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION FENCING. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. SECTION 323100 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting

More information

ATI Evaluation Service A Division of Architectural Testing Certification Services

ATI Evaluation Service A Division of Architectural Testing Certification Services ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 04/08/2014 Issued: 04/08/2013 Visit www.ati-es.com for current status Revision: 11/11/2013 Page 1 of

More information

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate. SECTION 05520 HANDRAILS AND RAILINGS PART 1 GENERAL 1.1 SECTION INCLUDES A. Welded stainless steel railing systems. 1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete; coordination with substrate.

More information

SECTION LUMINAIRES AND ACCESSORIES

SECTION LUMINAIRES AND ACCESSORIES SECTION 16500 LUMINAIRES AND ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to

More information

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project. SECTION 14651 FREE STANDING JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and industrial

More information

PIPE AND TUBE RAILINGS

PIPE AND TUBE RAILINGS SECTION 05521 - PIPE AND TUBE RAILINGS PART 1 GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS SECTION 08 4113 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Aluminum entrance doors and frames. 2. Glass infill panels. 3. Door hardware. B. Related Sections:

More information

DMS HIGH MAST LIGHT FIXTURES

DMS HIGH MAST LIGHT FIXTURES DMS - 11020 EFFECTIVE DATE: JANUARY 2012 11020.1. Description. This specification governs the materials, composition, and quality of 400 watt (W) high pressure sodium (HPS) tenon-mounted high mast light

More information

Solutions Railing Overview ACTUAL FREIGHT CHARGES APPLY TO ALL SOLUTIONS RAIL ORDERS

Solutions Railing Overview ACTUAL FREIGHT CHARGES APPLY TO ALL SOLUTIONS RAIL ORDERS 60 Aluminum Railing Systems SOLUTIONSTM Solutions Railing Overview Post to Post - PTP Solutions PTP application method is the traditional surface mount installation method with the rail terminating into

More information

Gibbs Morrison Cultural Center Site Improvements. Bid # ADDENDUM No. 1. July 25, 2017

Gibbs Morrison Cultural Center Site Improvements. Bid # ADDENDUM No. 1. July 25, 2017 Gibbs Morrison Cultural Center Site Improvements Bid # 7-4 ADDENDUM No. July 25, 207 Any and all changes to the Contract Document are valid only if they are included by written addendum to all potential

More information

SECTION ORNAMENTAL HANDRAILS AND RAILINGS

SECTION ORNAMENTAL HANDRAILS AND RAILINGS SECTION 05720 PART 1 - GENERAL ORNAMENTAL HANDRAILS AND RAILINGS 1.1 SUMMARY A. Section Includes: 1. Ornamental Handrails and Railings. 2. Glazed Panel Railings. 1.2 DEFINITIONS A. Guardrail: System of

More information

Georgia Amendments Prescriptive Deck Details

Georgia Amendments Prescriptive Deck Details Georgia Amendments Prescriptive Deck Details Based on the 2012 International Residential Code This design document applies to single-span, single-level residential decks only. Decks must be constructed

More information

Stairpans Stair Treads Landing Pans Carrier Angles Nosings Infill Panels U-Edging Hems

Stairpans Stair Treads Landing Pans Carrier Angles Nosings Infill Panels U-Edging Hems Stairpans Stair Treads Landing Pans Carrier Angles Nosings Infill Panels U-Edging Hems STAIR SYSTEMS CATALOG stairpans.com 2 Serving the Needs of Our Customers Since 1923 Eberl Iron Works, Inc. Founded

More information

ARCHITECTURAL SYSTEMS FOR LIFE SAFETY AND LIGHT

ARCHITECTURAL SYSTEMS FOR LIFE SAFETY AND LIGHT Welcome to Wagner Architectural Systems. We are a leading global provider of architectural railing systems dedicated to producing life safety and lighting products that meet the highest standards of quality,

More information

ARCHITECTURAL GLASS SYSTEMS

ARCHITECTURAL GLASS SYSTEMS ARCHITECTURAL GLASS SYSTEMS EXPLORE THE POSSIBILITIES Welcome to the evolution of glass railing life safety systems. Our highperformance glass railing systems combine the leading innovations in durability

More information

INDUSTRIAL GUARDRAIL SYSTEMS

INDUSTRIAL GUARDRAIL SYSTEMS INDUSTRIAL GUARDRAIL SYSTEMS STRONGEST GUARDRAIL ON THE MARKET MANUFACTURED IN THE U.S.A. BEST PRICES MOST VARIETIES HEAVY DUTY ONE-LINE OR TWO-LINE Posts: 4 Sched 80 pipe Rail: 6 Sched 40 pipe Sleeved

More information

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS

SECTION SOLID PHENOLIC PLASTIC TOILET PARTITIONS PRODUCT SPECIFICATION SERIES 1080/1180 PART 1 - GENERAL 1.01 Work Included SECTION 10170 SOLID PHENOLIC PLASTIC TOILET PARTITIONS A. Toilet Compartments B. Urinal Screens C. Shower Dividers D. Dressing

More information