ASSET MANAGEMENT WATER MAINS OWWA - OMWA
|
|
- Alison Erika Stewart
- 6 years ago
- Views:
Transcription
1 ASSET MANAGEMENT WATER MAINS OWWA - OMWA Water department Drinking water branch City of Montreal Serge Martin Paul, P.Eng. M.Eng., Project manager
2 Presentation plan ASSET MANAGEMENT WATER MAINS Overview of the network Context Asset management plan Case study
3 OVERVIEW OF THE NETWORK The network map Population served: 1.8 M people 6 water treatment plants 14 reservoirs
4 OVERVIEW OF THE NETWORK Distribution areas
5 OVERVIEW OF THE NETWORK The Plan network s du réseau assets Total water lines: 5045 km Distribution lines: 4305 km Water mains: 740 km 2500 Valve chambers, main network Concrete cylinder Pipe: 320 km Precast concrete cylinder Pipe C-301: 140km Metal pipe: steel, cast or ductile iron: 280 km Without external protection: 110 km With external protection: 30 km
6 Statistiques Statistics OVERVIEW PORTRAIT OF DU THE RÉSEAU NETWORK Pipes diameters Average age of the steel pipes Average age of the cast iron pipes Average age of the concrete pipes Total pipe length with a diameter 900 mm Total length of pipe with a diameter >900 mm et 1500 Total length of pipe with a diameter > 1500 mm 400 to 2700 mm 84 years 72 years 46 years 630 km 70 km 40 km
7 CONTEXT Issues and objectives Population growth, industrialization and an aging network are the key factors that pushed the city of Montreal to think about its role as a drinking water supplier The water fund creation in 2003 Adoption of the Montreal Charter of rights and responsibility in 2006 The City of Montreal commits to provide quality drinking water in sufficient quantity Montreal Water Strategy
8 MANAGEMENT PLAN GESTION DES ACTIFS Management cycle: inventory Water mains Valve chambers Inventory update
9 GIS: the visualization tools MANAGEMENT PLAN
10 Inventory MANAGEMENT PLAN PLAN DE GESTION Update TOTAL (m) ,00 Geo spatial data and pipe condition data Available documents # Pipe section Diam. (mm) Street From To Downtow n area Year of Length (m) installat ion Year of rehabilit ation Type of rehabil itation Material As built drawin gs Lay plans Key plans Tunnel - Servitude (Tréfonds) Tunnel - Servitude (Tréfonds) Réservoir Châteaufort Réservoir Châteaufort Atwater Centre A-40 (côté Nord) Usine Des Baillets n/a n/a n/a C-301-E A-206 Beauharnois n/a n/a n/a C-301-E A-205 Raccord 60'' (Atwater - Lymburner) OUI n/a n/a C-301-E A-179 A e/jarry n/a n/a n/a C-301-E A N-30, O-68 N-30 O-63 N-30
11 MANAGEMENT PLAN GESTION DES ACTIFS Management cycle: priorization Inventory update Water mains Valve Chambers Inspections priorization
12 Durée Materials de vie service life GESTION MANAGEMENT DES ACTIFS PLAN CONTEXTE MATERIALS SERVICE LIFE Materials Minimum Probable Maximum Steel Lined steel pipe Asbestos-cement Concrete cylinder pipe PCCP without external protection < PVC Cast iron between 1940 and 1965 Cast iron before 1940 and after 1965 Ductile iron 1979 and before Ductile iron after Lined cast iron Polyethylene C-301!!!
13 Defects by types of materials Problématiques par type de matériau MANAGEMENT PLAN MATERIALS COMMON DEFECTS Cast iron Ductile iron Steel Concrete cylinder pipe Precast concrete cylinder pipe, PCCP, C-301 Longitudinal, circomferential cracks X X Spiral cracks X X Pitting X X X X X Alteration of the concrete X X Cracks in the concrete X X Wire breaks X
14 MANAGEMENT PLAN Decision tree PCCP (C-301) 6 types of decisions (No action, inspection in 3 or 5 years, repair, rehab, replacement) 5 ratings Inspection data available? Spot repairs Water main break Diameter 400 mm New pipe for redundancy Can be inspected? Monitoring / Inspection Replacement 1 : Number of repairs 6 breaks or 2 :repair rate 2 breaks /km / year (according to hierarchy) Other projects? Service life 100% No action Service life 80% Concrete cylinder pipe PCP 1 : Number of repairs 6 breaks or 2 :Repair rate 2 breaks /km / year (according to hierarchy) Leak detection / inspection No action Replacement Leak detection / inspection Remplacement Service life 80% Other projects? No action Replacement Leak detection / Inspection
15 Decision tree: PCCP C-301 MANAGEMENT PLAN PCCP (C-301) 6 types of decisions (No action, inspection in 3 or 5 years, repair, rehab, replacement) 5 ratings Inspection data available? Spot repairs Water main break New pipe for redundancy Can be inspected? Monitoring / Inspection
16 Materials other than C-301 MANAGEMENT PLAN PCCP (C-301) Diameter 400 mm 1 : Number of repairs 6 breaks or 2 :repair rate 2 breaks /km / year (according to hierarchy) Service life 100% Replacement Other projects? No action Replacement Leak detection / inspection
17 MANAGEMENT PLAN Materials other than PCCP, C-301 PCCP (C-301) Diameter 400 mm Concrete cylinder pipe PCP Service life 80% 1 : Number of repairs 6 breaks or 2 :Repair rate 2 breaks /km / year (according to hierarchy) Leak detection / inspection No action Remplacement Service life 80% Other projects? No action Replacement Leak detection / Inspection
18 MANAGEMENT PLAN GESTION DES ACTIFS Management cycle: inspections Water mains Valve Chambers Inventory update Inspections Inspections priorizations
19 Résumé des divers types Types of inspection MANAGEMENT PLAN d inspection Electromagnetic inspection In-line acoustic leak detection Acoustic leak detection using correlator Visual internal and external inspection Acoustic monitoring (fiber optic)
20 Electromagnetic inspection MANAGEMENT PLAN Courtesy Pure Technologies
21 MANAGEMENT PLAN Inspection method by material INSPECTION METHODS Cast iron Ductile iron MATERIALS Steel Concrete cylinder pipe (PCP) Leak detection x x x x Visual internal and external inspeciton Electromagnetic inspection Acoustic monitoring Precast concrete cylinder pipe C- 301 x x x x x x x Courtesy Pure Technologies Hydrophones and acoustic correlators: Echologics
22 MANAGEMENT PLAN Valve chambers inspection Assigning a rating of 0 to 5 0. In excellent condition 1. Structure in good condition without visible presence of corrosion: To be re-inspected in 5 years 2. Stable structure with corroded elements: minor repairs needed 3. Moderately degraded structure requiring repairs in 1 to 3 years 4. Very damaged structure requiring a short-term intervention 5. Unstable structure requiring immediate action
23 MANAGEMENT PLAN Inspections results Valve chamber N-10-1 rating 1 Valve chamber O-12-4 rating 5
24 MANAGEMENT PLAN Leak detection and electromagnetic inspection ,49 Length in km ,03 5,4 10,28 4,83 11,96 3,62 7,63 7,67 4, ,65 1, Year Auscultation en km Détection de fuites en km inspected valve chambers
25 MANAGEMENT PLAN GESTION DES ACTIFS Management cycle: Repair, Rehab, Replacemnt Repair Rehabilitation Replacement Water mains Valve Chambers Inventory update Inspections Inspections priorization
26 Intervention Résumé des divers types MANAGEMENT PLAN d inspection Choose the type of intervention Target the intervention area Have an integrated planning Act at the right time = Better ressource management
27 Decarie Boulevard: Montreal CASE STUDY
28 Costs: 900 mm water main break Decarie Boulvard, April 2011 Police Traffic management $ Claims of citizens $ The break repair $ Social costs related to the closing of Decarie (2 weeks)? $ Support to the operation (city workers)? $ Total $ Inspection cost for 581 m of a 900 mm water main $ Cost of a planned repair $
29 CASE STUDY 2 Chemin de la Côte-Ste-Catherine Electromagnetic inspection Inspected length, October 2009 (from Darlington to Côte-des-neiges) 906 m Inspection cost $ Cost of spot repairs Total length replaced 87 m Replacement cost of 87 m $ Traffic control 3 weeks Replacement cost Total length to be replaced 906 m Replacement cost $ Traffic control for replacement 906 m 14 weeks
30 QUESTIONS?
epulse Acoustic Pipe Condition Assessment Director, Business Development
epulse Acoustic Pipe Condition Assessment Iain Davies: Matti Andersin: Director, Business Development Director Saint-Gobain Pipe Systems Echologics Technologies and Services for Leakage Reduction and Asset
More informationPredictive Models Based on Force Main Condition Assessment
Overview Let s focus on some general concepts: TSX: PUR global innovative sustainable infrastructure management solutions Predictive Models Based on Force Main Condition Assessment Understand failure modes
More informationIDEA Campus Energy 2015
IDEA Campus Energy 2015 Acoustic Pipe Wall Thickness Testing and Leak Detection in Aging Water Mains Water Efficiency, Capital Efficiency, and System Resiliency John Marciszewski, Director of Biz Dev Echologics
More informationWhen it Breaks, it Pours
When it Breaks, it Pours Large diameter pipeline breaks planning, maintenance, and condition assessment activities that can help prevent these high profile pipeline failures. 1 Howard County History Howard
More informationWhere Intelligence Meets Infrastructure PA AWWA Conference
Where Intelligence Meets Infrastructure 2017 PA AWWA Conference Analysis and Verification of PCCP Stiffness Testing Using Non-Invasive Acoustic Testing Name: John Marciszewski jmarciszewski@echologics.com
More informationAcoustic Fiber Optic Monitoring of PCCP and Pipelines of Other Materials. Stewart Day, Pure Technologies
Acoustic Fiber Optic Monitoring of PCCP and Pipelines of Other Materials Stewart Day, Pure Technologies 1 Presentation Outline PCCP Common failure modes Metallic pipe failure modes PCCP & metallic pipe
More informationAssessment Methods For Large Diameter Water & Sewer Pressure Pipelines
Assessment Methods For Large Diameter Water & Sewer Pressure Pipelines Procrastinator s Workshop Thursday, December 12, 2013 Presented by: Michael J. Livermore Midwest Regional Manager Solutions for Sustainable
More informationLinear Asset Management. Jennifer Steffens, P.E. Pure Technologies
Linear Asset Management Jennifer Steffens, P.E. Pure Technologies Utility Goals Reduce Failures Optimization of Capital Spend Top Water Industry Challenges 1. Infrastructure Renewal 2. Capital Improvement
More informationAcoustic Monitoring of Large Diameter Water Transmission Mains - City of Ottawa Case Study
Acoustic Monitoring of Large Diameter Water Transmission Mains - City of Ottawa Case Study CERIU - INFRA - 2011 Stewart Day, PURE Technologies, Regional Manager- Canada Shelley McDonald, City of Ottawa,
More informationLeak Detection in Pressurized Pipelines Using SmartBall Technology
Leak Detection in Pressurized Pipelines Using SmartBall Technology Mogan Padayachee Rand Water Services Johannesburg, South Africa Mike Wrigglesworth Pure Technologies Ltd. Benghazi, Libya Topics Importance
More informationThere are many technologies available for
Engineering Technologies for Pipeline Asset Management Bryon L. Livingston, Ahmad Habibian, and Dan Kugler There are many technologies available for managing the condition of underground infrastructure,
More informationAcoustic Methods for Determining Remaining Pipe Wall Thickness in Asbestos Cement and Ferrous Pipe
Acoustic Methods for Determining Remaining Pipe Wall Thickness in Asbestos Cement and Ferrous Pipe Asia Water, 27th March 2012 Mark Nicol, Regional Manager Asia Pacific Presentation Outline Why do we need
More informationHow does the PUC respond to Water Main breaks?
Are you curious about how the Peterborough Utilities Commission (PUC) responds to water main breaks and leaks? Do you want to know why some outages are short and some outages take longer to repair? Here
More informationBruce Power Pipeline Assessment Workshop. May 31, 2018
Bruce Power Pipeline Assessment Workshop May 31, 2018 Pure Technologies Over 30 years of experience in pressure pipe assessment and management Provided inspection, assessment, and management of thousands
More informationCity of Phoenix Superior Pipeline PCCP Investigation and Assessment
City of Phoenix Superior Pipeline PCCP Investigation and Assessment Ronald Ablin, P.E. 1, Brandy Kelso, P.E. 2, Bethany Williams, P.E. 3, Myron Shenkiryk 4, The City of Phoenix is currently in a multi-year
More informationAppendix A EXAMPLE COLLECTION SYSTEM PERFORMANCE INDICATOR DATA COLLECTION FORM
Appendix A EXAMPLE COLLECTION SYSTEM PERFORMANCE INDICATOR DATA COLLECTION FORM EXAMPLE COLLECTION SYSTEM PERFORMANCE INDICATOR DATA COLLECTION FORM I. General Information A. Agency Name B. Agency Address
More informationPipeline Condition Assessment. The Essential Engineering Step in the Asset Management Process
Pipeline Condition Assessment. The Essential Engineering Step in the Asset Management Process Tom Sangster. Principal, Jason Consultants Group, Geneva, Switzerland Synopsis Condition assessment is a critical
More informationCONDITION ASSESSMENT OF PRESSURE PIPELINES IN NUCLEAR POWER PLANTS: A CASE FOR NON-DESTRUCTIVE EVALUATION OF CONCRETE PRESSURE PIPES
More Info at Open Access Database www.ndt.net/?id=18582 CONDITION ASSESSMENT OF PRESSURE PIPELINES IN NUCLEAR POWER PLANTS: A CASE FOR NON-DESTRUCTIVE EVALUATION OF CONCRETE PRESSURE PIPES ABSTRACT E.
More informationForce Main Condition Assessment. Water Environment School March 2017
Force Main Condition Assessment Water Environment School March 2017 Safety Moment First Aid App Studies show that most workplace first aid training is forgotten over 90 days after certification Mobile
More informationImplementing a Risk- Based Main Replacement Strategy at EWEB
Eugene Water & Electric Board Implementing a Risk- Based Main Replacement Strategy at EWEB Chris Irvin, Senior Engineer PNWS-AWWA 2017 Presentation Overview About EWEB Introduction to risk concepts and
More informationRehabilitation of Lafayette Aqueduct No. 1
Rehabilitation of Lafayette Aqueduct No. 1 Marisa Boyce, P.E. October 1, 2013 CA-NV AWWA AFC 2013 Outline EBMUD Background History of Lafayette Aqueduct No. 1 Studies Temporary Repairs Long-term Plans
More informationInspection Tools Based on Risk
Inspection Tools Based on Risk Condition Rating Very Good (1) Good (2) Fair (3) Poor (4) Very Poor (5) Consequence of Fail lure (Criticality) Low Impact (1) Medium Impact (2) High Impact (3) Screening
More informationThe Nexus of Leak Detection and Asset Management
North American Water Loss Conference 2017 The Nexus of Leak Detection and Asset Management Roy Martinez Business Development Manager Agenda The problem The solution The process America s Infrastructure
More informationAdvances in Condition Assessment Technologies for Pipelines
Advances in Condition Assessment Technologies for Pipelines March, 2012 Cliff Jones Wachs Water Services Condition Assessment All pipes/ pipe materials leak All pipes can break 1 in 10 leaks will result
More informationIn-Service Forcemain Condition Assessment
In-Service Forcemain Condition Assessment Tim Ross and Reid McDougall TRENCHLESS TECHNOLOGY ROADSHOW May 28-29, 2014 Scotiabank Convention Centre, Niagara Falls, ON Agenda Project background & planning
More informationPublic Hearing December 12, 2013
Public Hearing December 12, 2013 Commission s Water Transmission System Finished Water Transmission System South Transmission Main South Transmission Main Route South Main Replacement Route from Provin
More informationEngineering Service THE ASSET MANAGEMENT APPROACH DEVELOPED BY THE CITY OF QUÉBEC OVER THE LAST 10 YEARS
Engineering Service THE ASSET MANAGEMENT APPROACH DEVELOPED BY THE OVER THE LAST 10 YEARS TRACKING DELIVERABLES January 2006 Implementation of corporate data base May 2009 Delivery of IP November 2009
More informationUsing Condition Assessment to more Efficiently Manage your Pipelines
Using Condition Assessment to more Efficiently Manage your Pipelines Traditional Management Approach Prioritize Pipelines Replace Pipelines Traditionally, prioritizations were based on age, material and
More informationPerformance Evaluation of Inspection and Protection Techniques Used in the Great Man-Made River Project in Libya
ISSN - (Paper) ISSN - (Online) Vol., No., 0 Performance Evaluation of Inspection and Protection Techniques Used in the Great Man-Made River Project in Libya OMRAN AHMAD ABUAZZA University of Portsmouth
More informationSilicon Valley Mid-Summer Emergency: Santa Clara Addresses Peak-Demand Repair of 96-inch Pipeline Mike Larsen Anna Pridmore, PhD, PE
Silicon Valley Mid-Summer Emergency: Santa Clara Addresses Peak-Demand Repair of 96-inch Pipeline Mike Larsen Anna Pridmore, PhD, PE BACKGROUND Santa Clara Valley Water District: Primary Water Source for
More informationSewerage Code WSA Addendum PART 4 - CONSTRUCTION
Addendum to the Water Industry Technical Standards and National Codes of Practice DOCUMENT W2 Sewerage Code WSA 02-1999 Addendum PART 4 - CONSTRUCTION Gippsland Water Business Management System Detailed
More informationTechnologies to Assess and Manage of Providence Water s 102 PCCP Aqueduct
Technologies to Assess and Manage of Providence Water s 102 PCCP Aqueduct Michael S. Higgins, P.E.; Paul J. Gadoury, P.E.; Peter LePage; Rich Razza; Jack Keaney, P.E.; Ian Mead, P.E. Michael S. Higgins,
More informationNumbers Don t Lie, PCCP Performance and Deterioration Based on a Statistical Review of a Decade of Condition Assessment Data
298 Numbers Don t Lie, PCCP Performance and Deterioration Based on a Statistical Review of a Decade of Condition Assessment Data Michael S. Higgins, P.E. 1 ; Allison Stroebele, P.Eng. 1 ; Sana Zahidi 1
More informationAGENDA ITEM. DATE: December 3, 2012
AGENDA ITEM B1 DATE: December 3, 2012 TO: FROM: Gerald J. Seeber, General Manager Charles H. Carden, Chief Operating Officer SUBJECT: South-Central Hillsborough Regional Wellfield Transmission Main Contract
More informationDeveloping a Strategic Asset Management Plan for Distribution System Valves
Developing a Strategic Asset Management Plan for Distribution System Valves By: George F. Meyers, P.E. City of Columbus Department of Public Utilities Division of Water What is the Problem to be Solved
More information60-Inch Water Main Failure in Chevy Chase and PCCP Program Update April 8, 2013
60-Inch Water Main Failure in Chevy Chase and PCCP Program Update April 8, 2013 2 What is the Problem? 15 Timeline Monday, March 18 13:03 Citizen Reports Water Bubbling Near 8101 Connecticut
More informationImplementing and Managing a Large Water Utility s Underground Corrosion-Control Program
Implementing and Managing a Large Water Utility s Underground Corrosion-Control Program Jeff Schramuk NACE CP Specialist #7695 630-235-1559 www.cpsolutionsinc.net Danny J. Klopfer, P.E. Infrastructure
More informationObservations from Several Condition Assessments of Prestressed Concrete Cylinder Pipe used at Energy Generation Facilities
147 Observations from Several Condition Assessments of Prestressed Concrete Cylinder Pipe used at Energy Generation Facilities Todd Stong PE 1, Ron R. Jorgenson 2, and Jacob Sauer 3 1 Senior Engineer,
More informationLADWP WATER INFRASTRUCTURE PLAN
LADWP 2017-18 WATER INFRASTRUCTURE PLAN Introduction All major components of the Water System infrastructure are evaluated as part of the ongoing Asset Management (AM) Program. The goal of AM is to systematically
More informationPerformance estimation of a remote field eddy current method for the inspection of water distribution pipes
Performance estimation of a remote field eddy current method for the inspection of water distribution pipes Sophie Duchesne - INRS Centre Eau Terre Environnement Nabila Bouzida Jean-Pierre Villeneuve Degradation
More informationCondition Assessment of Pipeline Systems Within Power Generating Plants
Condition Assessment of Pipeline Systems Within Power Generating Plants Condition Assessment of Pipeline Systems within Power Generating Plants Many cities depend on safe, reliable power delivered from
More informationAcoustic technology for internal live gas distribution pipeline inspection
GDN-17-08 Call for Innovation Acoustic technology for internal live gas distribution pipeline inspection Introduction The Energy Innovation Centre (EIC) works in partnership with the UK electricity and
More informationPipeline Condition Assessment Technology
Pipeline Condition Assessment Technology Presented by: Paul Schumi Collection Systems Fall Seminar December 1, 2016 water Asset Management Pipeline Assessment Hydrant Assessment Valve Assessment Leak Detection
More informationProtective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.
Protective Coatings for Underground Utility Concrete Structures By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc. As our cities and municipalities grow older, the utility and wastewater
More informationSingapore s Experience of Water Loss Reduction. Lai Kah Cheong Chief Engineer 7 Sep 17
Singapore s Experience of Water Loss Reduction Lai Kah Cheong Chief Engineer 7 Sep 17 Biodata of Singapore ~34km Singapore, 718 km2 ~53km Population, 5.6m Annual rainfall 2,400 mm Average water demand
More informationPNWS AWWA 2009 Annual Conference What s its Condition? Inspection of a Large Diameter Transmission Main
PNWS AWWA 2009 Annual Conference What s its Condition? Inspection of a Large Diameter Transmission Main Wayne Gresh, P.E. Project Manager, Black & Veatch greshhw@bv.com / 503-699-2218 May 6, 2009 Outline
More informationDUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS
DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS General All Materials shall be EN, ISO or equivalent standard and shall be supplied from approved manufacturers. According to the International
More informationWRF Research Efforts on Large Diameter Pipes
WRF Research Efforts on Large Diameter Pipes Water Research Foundation Metropolitan Water District, Los Angeles, January 20, 2016 Overview A variety of large diameter pipes covered PCCP CI & DI Steel HDPE
More informationEnvironmental Engineering-I
Environmental Engineering-I Prof. Dr. Muhammad Zulfiqar Ali Khan Engr. Muhammad Aboubakar Farooq Department of Civil Engineering The University of Lahore 1 Water Supply Pipes Valves Fire Hydrants 2 Water
More informationIntroduction and Overview of Condition Assessment. UKSTT Condition Assessment Masterclass
Introduction and Overview of Condition Assessment UKSTT Condition Assessment Masterclass 21 st September 2017 CA Overview Contents 1 Condition Assessment 2 Consequence of Failure 3 Condition Assessment
More informationEstablishment of Leakage Accident Rate Curves for Drinking Water Pipes
Establishment of Leakage Accident Rate Curves for Drinking Water Pipes H. Matsushita (Japan Water Research Center) Y. Takahashi Y. Suzuki (Japan Water Research Center) H. Taniguchi A. Koizumi (Tokyo Metropolitan
More informationData Management from Water Utility Perspective
Data Management from Water Utility Perspective Jim Pescatore, Vice President, CDM Smith Charlie Jewell, Director of Planning, Boston Water & Sewer Commission October 10, 2017 2017 Water Asset Management
More informationImplementation of Findings from Comparative Analysis of Pipe Materials Study for Large Diameter Transmission Watermains
STAFF REPORT ACTION REQUIRED Implementation of Findings from Comparative Analysis of Pipe Materials Study for Large Diameter Transmission Watermains Date: October 19, 2011 To: From: Wards: Reference Number:
More informationNo-Dig Technology is the art and science of pipes, ducts and cables using techniques that minimizes / eliminates the need for excavation, i.e.
No Dig Technology Introduction: No-Dig Technology is the art and science of installing, repairing or renewing underground pipes, ducts and cables using techniques that minimizes / eliminates the need for
More informationAdvantages of high quality PE pipe materials. Turkey Seminar - April 3, 2003
d o n t c r a c k u n d e r p r e s s u r e Advantages of high quality PE pipe materials Turkey Seminar - April 3, 2003 by Robin Bresser / PE100+ Association 4/2003 1 Creating value in Pipe - basic human
More informationMISENER DAM. Site Number LYNN STREET, PORT DOVER km N of Highway 6
NORFOLK COUNTY MISENER DAM Site Number 980501 LYNN STREET, PORT DOVER 0.65 km N of Highway 6 Ontario Structure Inspection Manual - Inspection Form Site Number: 980501 Inventory Structure Name Misener Dam
More informationPE Pipe Applications -Case Story
d o n t c r a c k u n d e r p r e s s u r e PE Pipe Applications -Case Story Marmara Earthquake İzmir Aliağa Thermal Power Plant 03 April 2003 - Ankara Hakan Belen 4/2003 1 Marmara earthquake In the past
More informationThe purpose of distribution system is to deliver water to consumer with appropriate quality, quantity and pressure. Distribution system is used to
Water Distribution System INTRODUCTION The purpose of distribution system is to deliver water to consumer with appropriate quality, quantity and pressure. Distribution system is used to describe collectively
More information2017 American Water Works Association
infrastructure IAN MEAD, AHMAD HABIBIAN, AND PETER LePAGE A Programmatic Approach to Pipeline Assessment and Rehabilitation Delivers Cost-Effective Solutions THE PIPELINE ASSESSMENT AND REPAIR PROGRAM
More informationTHOMAS. Buffalo Saddles. Tap In Products PIPE PRODUCTS. Universal Live Tap In Saddles for All Rigid Pipe Materials.
THOMAS PIPE PRODUCTS Tap In Products Buffalo Saddles Universal Live Tap In Saddles for All Rigid Pipe Materials A1 TAP IN PRODUCTS KITWE VALLEY - Copper Belt Province - Zambia PROJECT Kitwe Valley Pivot
More informationNorth Harris County Regional Water Authority TABLE OF CONTENTS. CONTRACT DOCUMENTS Section No. Title
TABLE OF CONTENTS CONTRACT DOCUMENTS 00001 Inside Title Page 00003 Table of Contents 00004 List of Drawings 00020 Invitation to Bid 00100 Instructions to Bidders 00300 Bid 00500 Agreement 00610 Construction
More informationSECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS
SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS To prevent the contamination of the public water supplies from nearby sanitary sewers, the following State Water Resources Control Board Division
More informationCONTRACTOR PREQUALIFICATION APPLICATION
CONTRACTOR PREQUALIFICATION APPLICATION Revised 12/17/13 ATTACHMENTS TO APPLICATION IN ORDER TO COMPLETE YOUR APPLICATION, IT IS VERY IMPORTANT THAT THE FOLLOWING ATTACHMENTS BE PROVIDED WHEN YOU SUBMIT
More informationAssessing Salem s Oldest Transmission Main for Seismic Resiliency
Assessing Salem s Oldest Transmission Main for Seismic Resiliency ASSESSING AND DEVELOPING OPTIONS TO REDUCE VULNERABILITY OF AGING CRITICAL INFRASTRUCTURE Presented by Troy Bowers, PE Jeff Jones, PE PROBLEM
More informationTown of Petrolia PRELIMINARY ASSET MANAGEMENT PLAN. Prepared by: Julie Fortier, ing. Marie-Élaine Desbiens, ing.
PRELIMINARY ASSET MANAGEMENT PLAN Prepared by: Julie Fortier, ing. Marie-Élaine Desbiens, ing. Verified by: Stuart Winchester, P.Eng. 236 Victoria Street North, Suite 301 Kitchener, Ontario N2H 5C8 Canada
More informationCIVIL ENGINEERING CONSTRUCTION SBC2253
CIVIL ENGINEERING CONSTRUCTION SBC2253 OIL AND GAS STRUCTURE Sr Dr. Mohd Saidin Misnan Department of Quantity Surveying Faculty of Built Environment Universiti Teknologi Malaysia INTRODUCTION Pipeline
More informationAGENDA ITEM C8. COST/FUNDING SOURCE: $215,348.48/Uniform Rate (Total project costs $520, includes $304,952 previously committed to Phase II)
AGENDA ITEM C8 DATE: February 6, 2017 TO: Matt Jordan, General Manager FROM: Charles H. Carden, Chief Operating Officer SUBJECT: South Pasco Transmission Main Phase III Condition Assessment Services with
More informationMaterial Specification for. Large Diameter Watermains
Engineering & Construction Services Division Standard Specifications for Sewers and Watermains TS 7.80 November 2016 Large Diameter Watermains Table of Contents TS 7.80.01 SCOPE... 2 TS 7.80.01.01 Application...
More informationExpansion of Existing Monitoring System on Great Man-Made River Project Using Acoustic Fibre Optic Technology
Expansion of Existing Monitoring System on Great Man-Made River Project Using Acoustic Fibre Optic Technology A. Lenghi*, N. Amaitik**, M. Wrigglesworth*** *Manager, Quality Assurance, Great Man-Made River
More informationTHOMAS. Buffalo Saddles. Tap In Products PIPE PRODUCTS. Universal Live Tap In Saddles for All Rigid Pipe Materials.
THOMAS PIPE PRODUCTS Tap In Products Buffalo Saddles Universal Live Tap In Saddles for All Rigid Pipe Materials A1 TAP IN PRODUCTS KITWE VALLEY - Copper Belt Province - Zambia PROJECT Kitwe Valley Pivot
More information7. Allowable Fittings.
7. Allowable Fittings. a. General Requirements. 1) The fittings listed in this section are generally the allowable fittings for the design of DIP and PVC pipe. For steel pipe and fittings, see Part One,
More informationIndex to Technical Specifications
Index to Technical Specifications Item Number Subject I II EXCAVATION 1.01 Trenching and Excavation Regulations 1.02 Site Grading or General Excavation 1.03 Structural Excavation 1.04 Trench Excavation
More informationCITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE
CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE 1000.1 DESCRIPTION These specifications shall govern the furnishing of glass-fiber reinforced
More information3/27/2018. Today s Presentation. Baltimore Department of Public Works. Background and Overview. Key Programs / Initiatives. Data Management / GIS
American Council of Engineering Companies (ACEC) Maryland Chapter Asset Management in City DPW Asset Management March in 28, Baltimore 2018 City DPW Today s Presentation Background and Overview Key Programs
More informationPIPE BREAK ANALYSIS WATER. Aldo Ranzani,
PIPE BREAK ANALYSIS WATER Aldo Ranzani, Public Works and Engineering Department City of Austin, Austin, Texas Executive Summary In an aging Water Distribution system such as that run by the City of Austin,
More informationGreetings from WSSC s Technical Services Group
Greetings from WSSC s Technical Services Group Hello I ve got out again 54 inch PCCP Break Dec 2003 Mike Woodcock C.Eng MIM 3 lapsed retired status mwoodco@wsscwater.com tel: 301-206-8572 fax: 301-206-8722
More informationPLANNING & DEVELOPMENT AIRPORT INFRASTRUCTURE MANAGEMENT MICHAEL SHEEHAN SR DIRECTOR OF AIM DEVELOPMENT
PLANNING & DEVELOPMENT AIRPORT INFRASTRUCTURE MANAGEMENT MICHAEL SHEEHAN SR DIRECTOR OF AIM DEVELOPMENT AIRPORT INFRASTRUCTURE MANAGMENT 2 FACILITY SERVICES Facility Development Capital Projects Management
More informationDEVELOPMENT OF A SUCCESSFUL UNTETHERED LEAK DETECTION AND PIPE WALL CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPELINES
DEVELOPMENT OF A SUCCESSFUL UNTETHERED LEAK DETECTION AND PIPE WALL CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPELINES Hugh Chapman, General Manager Aqua Environmental ABSTRACT Leak detection
More informationA. This Section includes gravity-flow, nonpressure storm drainage outside the building, with the following components:
SECTION 334100 - STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.I RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationCITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS SECTION 00005B TABLE OF CONTENTS ***CITY OF FRIENDSWOOD TECHNICAL SPECIFICATIONS***
00005B *** *** BOLD ITALICIZED Item is bound within this specification manual. Regular non-italicized Item is not bound within this specification manual, however item is part of the contract. Contents
More informationNMWD CASE STUDY ACOUSTIC AND VIDEO NON-DESTRUCTIVE TESTING OF 18 CONCRETE CYLINDER PIPE (AWWA C303) DREW McINTYRE NORTH MARIN WATER DISTRICT
NMWD CASE STUDY ACOUSTIC AND VIDEO NON-DESTRUCTIVE TESTING OF 18 CONCRETE CYLINDER PIPE (AWWA C303) DREW McINTYRE NORTH MARIN WATER DISTRICT 1 2 DISTRICT S MISSION STATEMENT TO PROVIDE AN ADEQUATE SUPPLY
More informationMichigan Department of Environmental Quality (MDEQ) Revolving Loan Section, Attn: Jonathan Berman
MEMORANDUM To: Michigan Department of Environmental Quality (MDEQ) Revolving Loan Section, Attn: Jonathan Berman From: OHM Advisors CC: City of Novi Oakland County Water Resources Commissioner Date: November
More informationMark Shepherd PrEng Consultant to ethekwini Water and Sanitation Durban, South Africa
Mark Shepherd PrEng Consultant to ethekwini Water and Sanitation Durban, South Africa Does Mains Replacement Always Reduce Real Losses? Results and Lessons Learned from a Largescale Mains Replacement Program
More informationWhen to Intervene? Using Rates of Failure to Determine the Time to Shut Down Your PCCP Line.
When to Intervene? Using Rates of Failure to Determine the Time to Shut Down Your PCCP Line. Mike Wrigglesworth; Pure Technologies, 300-705 11 th Ave SW, Calgary, AB, Canada, T2R 0E3; +1.403.266.6794 Michael
More informationPREDICTING THE REMAINING SERVICE LIFE OF WATER SYSTEM PIPES. Aldo Ranzani
PREDICTING THE REMAINING SERVICE LIFE OF WATER SYSTEM PIPES 1. Drought and Water Demand Aldo Ranzani Renew Austin Program Supervisor City of Austin Water Department 625 E 10 th Street, Suite 400 Austin,
More informationDEVELOPMENT OF A SUCCESSFUL INTERNAL LEAK DETECTION AND PIPELINE CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPES.
DEVELOPMENT OF A SUCCESSFUL INTERNAL LEAK DETECTION AND PIPELINE CONDITION ASSESSMENT TECHNOLOGY FOR LARGE DIAMETER PIPES Paper Presented by: Hugh Chapman Author: Hugh Chapman, General Manager, Aqua Environmental
More informationITEM 460 REINFORCED CONCRETE PIPE Description. This Item shall govern for the furnishing of reinforced concrete pipe.
AFTER MARCH 1, 2012 ITEM 460 REINFORCED CONCRETE PIPE 460.1 Description. This Item shall govern for the furnishing of reinforced concrete pipe. 460.2 Materials. A. Except as modified herein, materials,
More informationPOLSAFE. Gas Distribution System
POLSAFE Gas Distribution System PIPELIFE INTERNATIONAL Pipelife International GmbH is one of the world's leading suppliers of plastic piping systems. Plastic pipes and fittings are produced in 34 Pipelife
More informationDR MARK C WEBB. Managing Director. SSIS Sahara (Pty) Ltd. South Africa
DR MARK C WEBB Managing Director SSIS Sahara (Pty) Ltd South Africa LEAK DETECTION TECHNOLOGY PRECISE LEAK DETECTION TECHNOLOGY FOR ASSESSING THE CONDITION OF BULK WATER PIPELINES Outline 1. Pipeline Inspection
More informationThe Practical Application of Condition Assessment for Small Water Main Renewal. Dan Ellison, HDR, Ventura, CA November 14, 2017
The Practical Application of Condition Assessment for Small Water Main Renewal Dan Ellison, HDR, Ventura, CA November 14, 2017 Because NDE is seldom used for small mains..» Relatively strong mains are
More informationOakland County Water Resources Commissioner Common to All, SAW Grant No Wastewater and Stormwater Systems Asset Management Program
Oakland County Water Resources Commissioner Common to All, SAW Grant No. 1100-01 Wastewater and Stormwater Systems Asset Management Program Oakland County s office of the Water Resources Commissioner (WRC)
More informationPipelines & Liquid Storage Structures
Pipelines & Liquid Storage Structures The application of the Tyfo FIBRWRAP System in Pipelines and Liquid Storage Structures (Treatment Plants, Medium to large diameter Concreate and Steel Pipes, Reservoirs,
More informationONTARIO CENTRE FOR MUNICIPAL BEST PRACTICES 200 University Ave., Suite 801, Toronto, Ontario, M5H 3C6. BEST PRACTICE SUMMARY REPORT February, 2008
ONTARIO CENTRE FOR MUNICIPAL BEST PRACTICES 200 University Ave., Suite 801, Toronto, Ontario, M5H 3C6 BEST PRACTICE SUMMARY REPORT February, 2008 Water and Wastewater WATER LOSS MANAGEMENT CATHODIC PROTECTION
More informationDuring 2011, Utah State University conducted a basic survey
utility operations Steven Folkman, John Rice, Ammon Sorenson, and Nathan Braithwaite Survey of water main failures in the United States and Canada RESUltS OF A 211 SURveY OF UtilitieS IN THE United StateS
More informationNORFOLK STREET BRIDGE
Municipal Structure Inspection Form NORFOLK COUNTY NORFOLK STREET BRIDGE Site Number 000022 NORFOLK STREET NORTH, SIMCOE 0.09km N of Windham Concession 14 Road Ontario Structure Inspection Manual - Inspection
More informationSUPPLEMENTARY SECTION: STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018
STANDARD SPECIFICATIONS PAGE 1 STORMWATER MAINS & CULVERTS MAY 2018 PART 1 - GENERAL... 2 1.1 Work Included... 2 1.2 Related Sections... 2 1.3 Reference Standards... 2 1.4 Shop Drawings... 3 1.5 Certificates...
More informationWater & Industrial Products Catalog
Water & Industrial Products Catalog www.smith-blair.com info@smith-blair.com Phone: 800..9705 or 870.77.527 After Hours Number: 90.277.998 Fax: 800.8.792 or 870.77.52 EMERGENCY PHONE 90.277.998 In the
More informationWater Supply Citizens Advisory Committee. Metropolitan Tunnel Redundancy
Massachusetts Water Resources Authority Presentation to the Water Supply Citizens Advisory Committee on Metropolitan Tunnel Redundancy October 13, 2016 Status of Existing Transmission System Facilities
More informationVERIFICATION OF PCCP FAILURE MARGIN AND RISK CURVES
1413 VERIFICATION OF PCCP FAILURE MARGIN AND RISK CURVES Rasko P. Ojdrovic *, Peter D. Nardini, and Mehdi S. Zarghamee * Ph.D., P.E., M. ASCE, Principal, rpojdrovic@sgh.com, (781) 907-9231 P.E., A.M. ASCE,
More informationTCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II
SECTION 221313 - FACILITY SANITARY SEWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More information