Pedestal Style Poke-Thru Devices from Wiremold/ Legrand

Size: px
Start display at page:

Download "Pedestal Style Poke-Thru Devices from Wiremold/ Legrand"

Transcription

1 Pedestal Style Poke-Thru Devices IT, RC91GHBTC, RC92GHBTC Series High Capacity MultiService Power & Communication Poke-Thru Series Protection from water, dirt, and debris. Pedestal Style Poke-Thru Devices from Wiremold/ Legrand are an ideal solution for bringing large capacity power and communication services to workstations in an open space, above-grade floor environment. Every Pedestal Poke-Thru Device from Wiremold/ Legrand comes with built-in TopGuard protection, an industry-leading design that meets and exceeds UL scrub water exclusion requirements for tile and carpet floors. Topguard protection prevents water, dirt, or debris from entering the power and communication compartments located below the floor, through the service head or floor fittings. All Pedestal Poke-Thru Devices from Wiremold/Legrand can be installed on tile, carpet, or wood floors. Each of these devices provides an excellent solution for both new or retrofit construction, with typical applications that include commercial office buildings, financial institutions, and government facilities. IT with 241 Series Service Head on carpet floor. RC9GHBTC Pedestal Poke-Thru Device on tile floor. eatures & Benefits TopGuard Protection. Integral design component that prevents water, dirt and debris from entering power and communication compartments. Whenever you see the TopGuard protection icon on any Wiremold product, you ll know it meets and exceeds UL scrub water exclusion requirements for tile and carpet floors. UL Listed and UL ire Classified to U.S. and Canadian safety standards for tile and terrazzo. Includes the new UL requirements under UL514A and UL 514C for the scrub water exclusion test for carpet and wood floors. Available in single- or double-width service heads. Greater flexibility and capacity to meet customer power and communication requirements with lower initial cost. RC91GHBTC/RC92GHBTC Series provides a combination of one 1 1/4" and one 1/2" trade size conduit stem. Allows additional space to accommodate communication cables. IT Series provided with one 1" trade size divided conduit stem. Allows for dual service capability. Step-on-it installation. Quick and easy installation without the need for additional fasteners or a second installer. Variety of faceplate configurations available. lexibility to configure service fittings to meet workstation requirements now and in the future, reducing overall life cycle costs. IT Series is fire-rated for up to 4-hour rated floors. The RC91GHBTC and RC92GHBTC are fire-rated for up to 2-hour fire-rated floors. Maintains the 2- or 4-hour fire rating of the floor. Datacom connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point-of-use. ED1217R2 Updated May 2005 or latest specs visit

2 IT Series Ordering Information IT 2" [51mm] Poke-Thru Insert With Junction Box Assembly 1" trade size barriered conduit. Also includes BX/MC cable connector. 15 1/2" [394mm] NOTE: Must be activated with 200 Series or 241 Series Service Head and IP or P Series aceplates (sold separately) to maintain UL Listing and/or Classification. IT 200 Series Service Head Components With the IT Series, service heads can also be custom built. Combining a housing and base with individual faceplates allows the flexibility to custom design a service fitting to specific job requirements. One housing and base, as well as two faceplates, must be ordered to make a complete service head. These catalog numbers do not include receptacles. Example: To order a 200 Series Service Head with one blank faceplate and one Decora style opening faceplate, order the following: 1 pc. 200-H/BTC Housing and Base. Barrier included (may not be needed for single service applications). 1 pc. IP-B Single-gang plate - blank. 1 pc. IP-SS Single-gang plate with one Decora opening. 200-H/BTC 200 Series Housing and Base Order Information Housing and Base Single width. or 200 Series Service Head. Barrier included (may not be needed on single service applications). Base has a 3/4" trade size knockout for connection to IT insert. Also includes scrub water gasket. IP /8" [48mm] 4 5/8" [118mm] 200 Series aceplate Order Information aceplate Single-gang with one 1.390" [35.3mm] receptacle opening. IP-SS aceplate Single-gang with one 1.390" [35.3mm] receptacle opening. IP aceplate Single-gang with one 1.562" [39.7mm] receptacle opening. IP-T aceplate Single-gang faceplate with one telephone opening. Communication grommets included. IP-B aceplate Single-gang, blank. IP50 aceplate Single-gang with one 1/2" trade size knockout. IP-R aceplate Single-gang with one duplex receptacle opening. IP75 aceplate Single-gang with one 3/4" trade size knockout. 2

3 IT 241 Series Service Head Components With the IT Series, service heads can also be custom built. Combining a housing and base with individual faceplates allows the flexibility to custom design a service fitting to specific job requirements. One housing and base, as well as two faceplates, must be ordered to make a complete service head. These catalog numbers do not include receptacles. Example: To order a 241 Series Service Head with one blank faceplate and one faceplate with two duplex receptacle openings, order the following: 1 pc. 241H/BTC Housing and Base. Barrier included (may not be needed for single service applications). 1 pc. PB-B Two-gang plate Blank. 1 pc. P2R Two-gang plate with two duplex openings. 241-H/BTC 241 Series Housing and Base Order Information Housing and Base Double width. or 241 Series Service Head. Barrier included (may not be needed on single service applications). Base has opening for connection to IT insert. Also includes scrub water gasket. P /2" [64mm] 9" [229mm] 241 Series aceplate Order Information aceplate Two-gang with two 1.390" [35.3mm] receptacle openings. PB-B PSS-SS aceplate Two-gang, blank. aceplate Two-gang with two surge suppression device openings. P P2R aceplate Two-gang with two 1.562" [39.7mm] receptacle openings. aceplate Two-gang with two duplex receptacle openings. PB-ACT aceplate Two-gang. One Activate bezel included. Wiremold open inserts sold separately. P2T aceplate Two-gang with two telephone openings. Communication grommets included. PB-RT aceplate Two-gang. One Ortronics TracJack bezel included. One Ortronics Series II bezel included. lat connector only. P50-50 P75-50 aceplate Two-gang with two 1/2" trade size knockouts. aceplate Two-gang with one 3/4" and one 1/2" trade size knockout. PACT-ACT aceplate Two-gang. Two Activate bezels included. Wiremold open inserts sold separately. P75-75 aceplate Two-gang with two 3/4" trade size knockouts. PB-2RT aceplate Two-gang. Two Ortronics TracJack bezels included. Two Ortronics Series II bezels included. lat connector only. 3

4 IT Series Poke-Thru Accessories Order Information AP-ITTC Poke-Thru Abandonment Plate 2" [51mm]. NOTE: Stem must remain in cored hole CARPET ire-rated Plug or carpet applications. IT-EXT Assembled Extension 4 5/8 [118mm]. Includes 1" trade size barriered conduit and coupling. or use with slabs greater than 8" [203mm] TILE ire-rated Plug or tile applications. TG-1 Communication Grommets One set of two grommets. IT Poke-Thru Series Order Information or a Single-Width Service Head Application: or a Double-Width Service Head Application: 1. Order the IT Poke-thru itting. 1. Order the IT Poke-thru itting. 2. Order the 200-H/BTC Service Head. 2. Order the 241-H/BTC Service Head. 3. Order two faceplates. 1 7/8" [48mm] IP /8" [118mm] IP-R IP50 3. Order two faceplates. 2 1/2" [64mm] 9" [229mm] PB-B P75-75 PB-ACT IP IP-SS IP75 P2R PSS-SS PB-RT IP-B IP-T P2T PACT-ACT PB-2RT 4. Completed Assembly. P Completed Assembly. IMP ANT! All faceplate openings must be closed off if not used, to maintain the fire rating of the device. 4

5 Copper Cross Section: The copper cross-sectional area determines the amount of wire fill capacity in a poke-thru device. Unlike other wire and cable management systems that utilize wire fill capacity, a poke-thru device is UL tested under fire conditions to determine the maximum amount of copper conductors that will pass through a poke-thru device, while maintaining the fire-rating of the concrete slab. The IT with 200 or with 241 Series Service Heads are UL Classified to U.S. and Canadian safety standards (see complete marking on product) to accommodate the following: Maximum Allowable Copper Cross Sectional Area: 200 Series Service Head (Power/Communication Combined). Power compartment = sq. in. [9.91mm 2 ]. Communication compartment = sq. in. [32.39mm 2 ]. IT Series Poke-Thru Specifications 200 Series Service Head (Power only) = sq. in. [42.94mm 2 ]. 200 Series Service Head (Communication only) = sq. in. [42.10mm 2 ]. 200 H/BTC 241 Series Service Head (Power/Communication Combined). Power compartment = sq. in. [23.12mm 2 ]. Communication compartment = sq. in. [32.39mm 2 ]. 241-H/BTC 241 Series Service Head (Power only) = sq. in. [52.85mm 2 ]. 241 Series Service Head (Communication only) = sq. in. [55.06mm 2 ]. Junction Box: Supplied with every insert. 16-gauge C.R.S. galvanized box having the following cubic content, complete with 1/2" and 3/4" trade size knockouts. (Power only...30 cu. in. [492cu cm]. Combination...25 cu. in. [410cu cm]). NOTE: The IT Series Poke-Thru requires a 2" [51mm] cored hole. Copper Cross Sectional Area of Commonly Used Conductors Size Solid # sq. in. [.20645mm 2 ] # sq. in. [.32258mm 2 ] # sq. in. [ mm 2 ] # sq. in. [ mm 2 ] # sq. in. [ mm 2 ] NOTE: Use above values for solid or stranded conductors. loor Coverings: The poke-thru device is fire rated for carpet covered floors, tile floor coverings up to 3/4" [19.1mm] maximum thickness, and linoleum floor coverings up to a maximum of 1/8" [3.2mm] thickness. or other floor coverings not listed above, consult factory. CAUTION: Core bits vary in size from manufacturer to manufacturer. Use a 2" [51mm] American made core bit having an outside diameter of 2 1/16" [53mm]. Minimum hole diameter: 2 1/32" [52mm]. Maximum hole diameter: 2 1/8" [54mm]. CAUTION: These devices meet all UL scrub water requirements, but are not suitable for wet or damp locations, or other areas subject to saturation with water or other liquids such as commercial kitchens. IMP ANT! The above maximum copper cross sectional area values are for each individual power and communication compartment. DO NOT add values together for any one compartment. 5

6 RC91GHBTC RC91GHBTC Poke-Thru Series Ordering Information Poke-Thru Insert and Single Width Service Head Includes insert stem with disposable plate and service head with housing, base, scrub water gasket, and barrier. Service head and insert install together to make a poke-thru assembly. Combine with faceplates (sold separately) to complete service head assembly. NOTE: Part shown assembled. Service head is shipped unassembled with the insert stem. 291-H/BTC RC9S Single Width Service Head Only Includes housing, base, scrub water gasket, and barrier. Use with insert assembly RC9S. Insert Stem with Disposable Plate urniture feed insert with one 1 1/4" and one 1/2" trade size conduit to feed power and communication services. Use with either 291-H/BTC or 292-H/BTC Service Head to form complete unit. RC91GHBTC Series aceplate Ordering Information IP Single-Gang aceplate With one 1.390" [35mm] receptacle opening. 4 5/8" [118mm] IP-SS Single-Gang aceplate With one surge suppression device opening. 1 7/8" [48mm] IP Single-Gang aceplate With one 1.562" [40mm] receptacle opening. IP-T Single-Gang aceplate With one communication opening. Two communication grommets included. IP-B Single-Gang aceplate Blank. IP50 Single-Gang aceplate With one 1/2" trade size opening. IP-R Single-Gang aceplate With one duplex receptacle opening. IP75 Single-Gang aceplate With one 3/4" trade size opening. 6

7 RC92GHBTC RC92GHBTC Poke-Thru Series Ordering Information Poke-Thru Insert and Double Width Service Head Includes insert stem with disposable plate and service head with housing, base, scrub water gasket, and barrier. Service head and insert install together to make a pokethru assembly. Combine with faceplates (sold separately) to complete service head assembly. 292-H/BTC Double Width Service Head Only Includes housing, base, scrub water gasket, and barrier. Use with insert assembly RC9S. NOTE: Part shown assembled. Service head is shipped unassembled with the insert stem. RC9S Insert Stem with Disposable Plate urniture feed insert with one 1 1/4" and one 1/2" trade size conduit to feed power and communication services. Use with either 291-H/BTC or 292-H/BTC Service Head to form complete unit. RC92GHBTC Series aceplate Ordering Information PB-B Two-Gang aceplate Blank. 9" [229mm] P50-50 Two-Gang aceplate With two 1/2" trade size openings. 2 1/2" [64mm] P2R Two-Gang aceplate With two duplex receptacle openings. P75-75 Two-Gang aceplate With two 3/4" trade size openings. P2T Two-Gang aceplate With two communication openings. our communication grommets included. PSS-SS Two-Gang aceplate With two surge suppression device openings. 7

8 RC92GHBTC Series aceplate Ordering Information (Continued) PACT-ACT Two-Gang aceplate Two Activate bezels included. Wiremold open inserts sold separately. PB-ACT Two-Gang aceplate One Activate bezel included. Wiremold open inserts sold separately. PB-2RT Two-Gang aceplate Two Ortronics TracJack bezels included. Two Ortronics Series II bezels included. lat connectors only. PB-RT Two-Gang aceplate One Ortronics TracJack bezel included. One Ortronics Series II bezel included. lat connectors only. IMP ANT! All faceplate openings must be closed off if not used, to maintain the fire rating of the device. Multiservice Poke-Thru Series Accessories Ordering Information ABPLUG3 Abandonment Plug Assembly Complete plug assembly for 3 3/16" [97mm] 7" [178mm] abandoning an open 3" [76mm] cored-hole. Assembly includes intumescent fire-stop material to maintain the fire-classification of the floor, integral retainer ring to prevent the unit from pulling up through the floor, and a black die-cast aluminum cover. TG-1 Communication Grommets One set of two grommets (one grommet shown). RCAPTCBK Abandonment Plate Black. 8

9 Multiservice Poke-Thru Series Ordering Information or a Single Width Service Head Application: or a Double Width Service Head Application: 1. Order the RC91GHBTC Poke-Thru itting and Service Head: 1. Order the RC92GHBTC Poke-Thru itting and Service Head: NOTE: Service head is shipped unassembled. 2. Order two faceplates: NOTE: Service head is shipped unassembled. 2. Order two faceplates: 1 7/8" [48mm] 4 5/8" [118mm] 2 1/2" [64mm] 9" [229mm] PB-B IP IP-SS P75-75 IP IP-T P2R PSS-SS IP-B IP50 P2T PACT-ACT P50-50 PB-ACT IP-R IP75 PB-RT PB-2RT 3. Completed Assembly: 3. Completed Assembly: 9

10 Multiservice Series Specifications Copper Cross Section: The copper cross-sectional area determines the amount of wire fill capacity in a poke-thru device. Unlike other wire and cable management systems that utilize wire fill capacity, a poke-thru device is UL tested under fire conditions to determine the maximum amount of copper conductors that will pass through a poke-thru device, while maintaining the fire-rating of the concrete slab. The Multiservice Series is UL Classified to U.S. and Canadian safety standards (see complete marking on product) to accommodate at a maximum the following: Maximum Allowable Copper Cross Sectional Area: 291 Series Service Head (Power/Communication Combined). Power compartment = sq. in. [9.91mm 2 ]. Communication compartment = sq. in. [32.39mm 2 ]. 291 Series Service Head (Power only) = sq. in. [42.94mm 2 ]. 291 Series Service Head (Communication only) = sq. in. [42.10mm 2 ]. 292 Series Service Head (Power/Communication Combined). Power compartment = sq. in. [33.03mm 2 ]. Communication compartment = sq. in. [32.39mm 2 ]. When using flexible metallic conduit the communication compartment can be increased to sq. in. [64.77mm 2 ]. Copper Cross Sectional Area of Commonly Used Conductors Size Solid # sq. in. [.20645mm 2 ] # sq. in. [.32258mm 2 ] # sq. in. [ mm 2 ] # sq. in. [ mm 2 ] # sq. in. [ mm 2 ] NOTE: Use above values for solid or stranded conductors. IMPANT! The above maximum copper cross sectional area values are for each individual power and communication compartment. DO NOT add values together for any one compartment. Tile, Terrazzo, Linoleum, or Carpet 292 Series Service Head (Power only) = sq. in. [42.94mm 2 ]. 292 Series Service Head (Communication only) = sq. in. [42.10mm 2 ]. When using flexible metal conduit the communication compartment can be increased to sq. in. [64.77mm 2 ]. loor Coverings: The poke-thru device is fire rated for carpet covered floors, tile floor coverings up to 3/4" [19.1mm] maximum thickness, and linoleum floor coverings up to a maximum of 1/8" [3.2mm] thickness. or other floor coverings not listed above, consult factory. Scrub Water Gasket 1/2" Trade Size EMT Conduit 8 3/4" [222mm] Long Side View of Service Head Concrete Slab 1 1/4" Trade Size EMT Conduit 5 3/4" [146mm] Long Communication Cables Concrete Thickness Min/Max: 1-HOUR RATED LOOR 2 1/4" [57mm] min over top of deck (or 3" [76mm] thick reinforced concrete slab) to a maximum of 7 1/2" [191mm]. 2-HOUR RATED LOOR 3 1/4" [83mm] min over top of deck (or 4" [102mm] thick reinforced concrete slab) to a maximum of 7 1/2" [191mm]. Junction Box (Not Supplied) Can Be Used to Make Power Connections NOTE: The Multiservice Poke-Thru Series requires a 3" [76mm] cored hole. CAUTION: Core bits vary in size from manufacturer to manufacturer. Use a 3" [76mm] American made core bit having an outside diameter of 3 1/16" [78mm]. Minimum hole diameter: 3 1/16" [78mm]. Maximum hole diameter: 3 1/8" [79mm]. CAUTION: These devices meet all UL scrub water requirements, but are not suitable for wet or damp locations, or other areas subject to saturation with water or other liquids such as commercial kitchens. 10

11 Notes Guide orm Specs CAD Drawings Available 11

12 Datacom Connectivity Options Now you have a wide range of options for providing datacom connectivity into Wiremold Cable Management Systems. They are: Ortronics TracJack and Series II Modular Connectivity Solutions Pass & Seymour Activate Modular Inserts Open System Communication Modules Use these icons to determine connectivity options for each Wiremold System component: Ortronics Connectivity TracJack Individual Jack System ront-loading, snap-in design supports future moves adds and changes Inserts for voice, data, audio, and video Available Category 3, 5e, 6, USOC 6-position, and other media Choice of 13 colors and color matched to Wiremold Systems Universal T568A/B wiring format Series II ront-loading, Module System Module design features easy snap-in front-loading design Linear 110 punch down format for easy termination Inserts for voice, data, audio, and video Available Category 3, 5e, 6, USOC 6-position, and other media Color matched to Wiremold Systems or detailed product selection refer to the Ortronics Catalog or visit Pass & Seymour Legrand Network Wiring Activate Series ront-loading Inserts Modular inserts for voice, data, audio and video applications ront-load, snap-in design Color and texture matched to Wiremold Systems Available Category 3, 5e, 6, as well as 6-position USOC Universal T568A/B wiring format or detailed product selection refer to the Pass & Seymour Network Wiring Catalog or visit Open Connectivity Solutions Wiremold Open System Communications Modules Accommodate a wide range of manufacturers communications outlets including keystone jacks, as well as proprietary solutions from Avaya (Lucent) and NORDX Modules insert into a wide range of Wiremold Systems Pre-punched faceplates accept common communication devices NOTE: or more information on integrating connectivity into Wiremold Cable Management Systems contact the Wiremold Applications Engineering Team or your local Wiremold Sales Representative. Wiremold / Legrand U.S. and International: 60 Woodlawn Street West Hartford, CT AX Outside U.S Canada: 570 Applewood Crescent Vaughan, Ontario L4K 4B AX Copyright 2005 The Wiremold Company All Rights Reserved ED1217R2 Updated May 2005 or latest specs visit

WIREMOLD Pedestal Style Poke-Thru Devices

WIREMOLD Pedestal Style Poke-Thru Devices WIREMOLD Pedestal Style Poke-Thru Devices High Capacity Multiservice Power & Communication Poke-Thru Devices Protection from water, dirt, and debris. Pedestal Style Poke-Thru Devices are an ideal solution

More information

The RFB11 and RFB9 Series Floor

The RFB11 and RFB9 Series Floor RFB11 & RFB9 Recessed Floor Box Series Large Capacity Floor Boxes for Power, Communication, Audio, and Video Applications Protection from water, dirt, and debris. The RFB11 and RFB9 Series Floor Boxes

More information

F E A T U R E S & B E N E F I T S

F E A T U R E S & B E N E F I T S WIREMOLD Furniture Feed Style Poke-Thru Devices Bring Power & Communication Services to Modular Furniture Systems Protection from water, dirt, and debris. Wiremold Furniture Feed Style Poke-Thru Devices

More information

WIREMOLD Furniture Feed Style Poke-Thru Devices

WIREMOLD Furniture Feed Style Poke-Thru Devices WIREMOLD Furniture Feed Style Poke-Thru Devices Bring Power & Communication Services to Modular Furniture Systems Protection from water, dirt, and debris. Furniture Feed Style Poke-Thru Devices are an

More information

RC7 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005

RC7 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005 RC7 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: 1 001 628 R2 Updated April 2005 Wiremold Electrical Systems conform to and should be installed and properly grounded in compliance

More information

RC4 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005

RC4 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005 RC4 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: 1 001 636 R2 Updated April 2005 Wiremold Electrical Systems conform to and should be installed and properly grounded in compliance

More information

WALKER FLOOR BOXES STILL LOOKING AT FLOOR BOXES IN THE SAME OLD WAY?

WALKER FLOOR BOXES STILL LOOKING AT FLOOR BOXES IN THE SAME OLD WAY? WALKER FLOOR BOXES STILL LOOKING AT FLOOR BOXES IN THE SAME OLD WAY? UPDATED FLOORPORT COVER DESIGN 880 Series Floor Box Then you re missing the big picture. Ratchet-Pro Round PVC Floor Box Wood Floor

More information

Introducing the next generation in innovative surface raceway systems. The new 4000 Designer Series Aluminum

Introducing the next generation in innovative surface raceway systems. The new 4000 Designer Series Aluminum Innovative Aluminum Raceway Profile Provides Increased Wiring Capacity Available Factory Prewired 4000 Designer Series Aluminum Raceway Introducing the next generation in innovative surface raceway systems.

More information

RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R3 Updated April 2005

RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R3 Updated April 2005 RC9 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: 1 002 947 R3 Updated April 2005 Wiremold Electrical Systems conform to and should be installed and properly grounded in compliance

More information

Abuilding s Wire Management System may be able to

Abuilding s Wire Management System may be able to Cellular Raceway, Junction Boxes, Fittings, and Headerduct Walkercell Cellular Raceway Abuilding s Wire Management System may be able to accommodate demands on it when the building is first occupied. But

More information

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

Evolution Series. 8" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 8 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

FLOOR FLOOR AND ANY VISION. FOR ANY WIREMOLD FLOOR BOXES. designed to be better.

FLOOR FLOOR AND ANY VISION. FOR ANY WIREMOLD FLOOR BOXES. designed to be better. FLOOR FOR ANY FLOOR 2013 Legrand All Rights Reserved ED933R4 03 13 A WIREMOLD FLOOR BOXES Electrical Wiring Systems 60 Woodlawn Street West Hartford, CT 06110 1.877.BY.LEGRAND (295.3472) www.legrand.us

More information

Evolution Series. 6" Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning.

Evolution Series. 6 Poke-Thru Devices I N S T A L L A T I O N I N S T R U C T I O N S. IMPORTANT: Please read all instructions before beginning. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 CONDITIONS AND REQUIREMENTS A. The General Conditions, Supplementary Conditions, and Division 1 General Requirements apply.

More information

FLOOR AND ANY VISION. FOR ANY FLOOR. designed to be better.

FLOOR AND ANY VISION. FOR ANY FLOOR. designed to be better. AND ANY VISION. A FLOOR FOR ANY FLOOR 2018 Legrand All Rights Reserved ED933R6 10 18 WIREMOLD FLOOR BOXES Any way you look at it, Legrand delivers. Wiremold Floor Boxes offer a choice like no other. Accommodating

More information

WIREMOLD Evolution Series Floor Boxes

WIREMOLD Evolution Series Floor Boxes WIREMOLD Evolution Series Floor Boxes Evolution Series Maintaining the Floor s Fire Rating Evolution Series Fire Classified Floor Boxes are the latest advancement in the most complete and innovative line

More information

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS 1.GENERAL SECTION 16130 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS 1. CONDITIONS AND REQUIREMENTS A. The General Conditions, Supplementary Conditions, and Division 1 General Requirements apply. 2. SECTION

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

WIREMOLD Flush Style Poke-Thru Devices

WIREMOLD Flush Style Poke-Thru Devices WIREMOLD Flush Style Poke-Thru Devices Bring Power & Communication Services Directly to the Workstation Protection from water, dirt, and debris. Flush Style Poke-Thru Devices are an excellent solution

More information

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System

Raceway Solutions TM. Conventional Underfloor Duct. Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System Multi-Compartment Conventional Duct Saves Time and Money in Your In-Slab Wire Management System The Raceway Solutions System is an in-slab wire management product for delivering power, voice and data services

More information

PRODUCT GUIDE. Connectivity with flexibility.

PRODUCT GUIDE. Connectivity with flexibility. PRODUCT GUIDE Connectivity with flexibility www.smartdesks.com ADA COMPLIANT - U.L. TESTED AND LISTED 2011 STRONG PRODUCTS GROUP, LTD. Connectrac systems are protected by US Patent Nos. 6,844,493 and 6,566,598;

More information

Floor Box Assembly. Features. Dimensions and Weight. Descriptions. Catalog Number

Floor Box Assembly. Features. Dimensions and Weight. Descriptions. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 EFBFF Floor Box Assembly Wiremold/Legrand Catalog Number EFBFF Manufacturer Wiremold/Legrand Description Furniture Feed

More information

Flush Service Floor Boxes

Flush Service Floor Boxes Flush Service Floor Boxes PRODUCT SPECIFICATION: Flush Service Floor Boxes PART 1: Overview Considerations when writing specifications: Floor boxes are manufactured in various sizes, configurations and

More information

PN05L08V PN5 8FT Latching Rcwy V. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

PN05L08V PN5 8FT Latching Rcwy V. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 PN05L08V PN5 8FT Latching Rcwy V Wiremold/Legrand Catalog Number Manufacturer Description Weight per unit Product Category

More information

Plastic Floor Box. Wiring Device-Kellems

Plastic Floor Box. Wiring Device-Kellems Plastic Floor Box Wiring Device-Kellems Plastic Floor Boxes by Hubbell: The Inside Story is Outstanding For the real story on plastic floor boxes, start on the inside. Because, while all plastic floor

More information

FPT4 SERIES POKE-THROUGHS INSTALLATION INSTRUCTIONS

FPT4 SERIES POKE-THROUGHS INSTALLATION INSTRUCTIONS FPT4 SERIES POKE-S INSTLLTION INSTRUCTIONS WRNING ELECTRICL HZRD! E SURE IS OFF! IMPORTNT - PLESE RED LL INSTRUCTIONS EFORE EGINNING. WRRNTY ND FIRE RESISTNCE RTING RE VOID IF PRODUCT INSTLLTION IS NOT

More information

ROBERTSON "3 + 1" SLAB-ON-GRADE SINGLE LEVEL RACEWAY SYSTEM (Revised July 2000)

ROBERTSON 3 + 1 SLAB-ON-GRADE SINGLE LEVEL RACEWAY SYSTEM (Revised July 2000) ROBERTSON "3 + 1" SLAB-ON-GRADE SINGLE LEVEL RACEWAY SYSTEM (Revised July 2000) PART 1 - GENERAL 1.01 SCOPE Furnish complete electrical distribution system including: Cellular deck units, trench headers,

More information

For large capacity, easy installation and

For large capacity, easy installation and Trenchduct Trenchduct Feeder System for Wallduct, Underfloor Duct, and Cellular Raceways For large capacity, easy installation and future flexibility, trenchduct is the feeder system of choice for infloor

More information

IMPORTANT - PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING. SAVE THESE INSTRUCTIONS FOR REFERENCE AND ADDITIONAL WORK REQUIRED AFTER CONCRETE POUR.

IMPORTANT - PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING. SAVE THESE INSTRUCTIONS FOR REFERENCE AND ADDITIONAL WORK REQUIRED AFTER CONCRETE POUR. Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current National Electrical Code or codes administered by local authorities. All electrical

More information

WIREMOLD Trenchduct Feeder Systems

WIREMOLD Trenchduct Feeder Systems Trenchduct Feeder System for Wallduct, Underfloor Duct, and Cellular Raceways WIREMOLD Trenchduct Feeder Systems Wiremold Trenchduct Feeder Systems are the first choice for infloor distribution raceways

More information

SECTION PATIENT BED SERVICE WALLS

SECTION PATIENT BED SERVICE WALLS PART 1 GENERAL 1.1 DESCRIPTION: SECTION 10 25 13 PATIENT BED SERVICE WALLS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Due to the very specialized nature of Patient Wall

More information

Also available in Premium Finishes See submittal SUB for Premium Finishes

Also available in Premium Finishes See submittal SUB for Premium Finishes PM1 DUAL J TREE STRAP CATALOG NUMBER: LAMP(S): NOTES: Example PM1DJ - TS-20-1 - BZP - SC Series PM1DJ Mounting TS - Length Fixture Position - Tree Strap (Specify Adjustable Strap Length) Minimum 3" Adjustable

More information

SECTION CONDUIT AND BOXES

SECTION CONDUIT AND BOXES PART 1 - GENERAL 1.01 SUMMARY SECTION 27 05 33 CONDUIT AND BOXES A. This Section includes specific requirements for conduits and boxes within the Communications Pathway System as defined in Division 27

More information

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS

PHYSICAL FACILITIES Consultant s Handbook Division 27 COMMUNICATIONS 0000 COMMUNICATIONS 1 Introduction 1.1 In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a utility. It should be assumed that all new

More information

AMTC412 Wiremold Amtc-412 TPP Blank Alum. Features Made in USA. Material, Color, and Finish. Dimensions and Weight.

AMTC412 Wiremold Amtc-412 TPP Blank Alum. Features Made in USA. Material, Color, and Finish. Dimensions and Weight. 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AMTC412 Wiremold Amtc-412 TPP Blank Alum Wiremold/Legrand Catalog Number Manufacturer Description Weight per unit Product

More information

Wall studs. Wall Studs

Wall studs. Wall Studs 15 Box To Stud Fastener Attaches with screws to metal studs. BB1 supports electrical box. BG series features Guide-Rite design. BP series features push-type design. 78101118145 BB1 Electrical Box 100 Support

More information

FPBTCBK D/C Al FLGD CVR. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

FPBTCBK D/C Al FLGD CVR. Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Material Number of Gangs Service Type

More information

FloorBoxes. f r o m T h o m a s & B e t t s

FloorBoxes. f r o m T h o m a s & B e t t s FloorBoxes f r o m T h o m a s & B e t t s T h i s b r o c h u r e p r e s e n t s a n o v e r v i e w o f t h e f l o o r b o x p r o d u c t o f f e r i n g a v a i l a b l e from Thomas & Betts including:

More information

1 data PIC location (with 2 ports) typically asf for multiple staff members

1 data PIC location (with 2 ports) typically asf for multiple staff members 1 Introduction 1.1 In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a utility. It should be assumed that all new

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

Communications Page 1 of 9

Communications Page 1 of 9 Page 1 of 9 Last Update: April 23 rd, 2014 Introduction Design In the design of Telecommunications systems in Purdue facilities, the overall consideration should be to understand and treat telecom as a

More information

MONO-SYSTEMS, INC. UNIQUE CABLE DISTRIBUTION SOLUTIONS

MONO-SYSTEMS, INC. UNIQUE CABLE DISTRIBUTION SOLUTIONS Printed in U.S.A. Mono Systems, Inc. reserves the right to design changes without notification 4 International Drive Rye Brook, New York 10573 Tel: [914] 934-2190 Fax: [914] 934-2190 IFSSG.LIT.6/07 Poke

More information

Trench Duct Class Catalog 5230CT9601R10/08

Trench Duct Class Catalog 5230CT9601R10/08 5230CT9601R10/08 2009 Class 5230 CONTENTS Application.................................................5 Unassembled Trench Duct Components.........................6 Factory Assembled Trench Duct..............................11

More information

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS PART 1 - GENERAL 01.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification sections, apply to work of this Section.

More information

Utility Cabinet System (UCS)

Utility Cabinet System (UCS) (UCS) The Ultimate in Stainless Steel Modular Walls UCS: Eliminates the need and the costs of constructing a traditional wall Provides easier access and faster installation of the utilities compared to

More information

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SD1 4S Box 1"Ko 2-1/8DP Appleton/Oz Gedney Catalog Number 4SD1 Manufacturer Appleton/Oz Gedney Description Steel Square

More information

New Product Flyer Introduction

New Product Flyer Introduction Dec. 5, 2013 New Product Flyer Introduction Preferred Lightning Protection, Inc. is excited to introduce our newest products and capabilities. Following are several new products with current inventories

More information

`bfifkd=c^k=prmmloq=molar`qp

`bfifkd=c^k=prmmloq=molar`qp `bfifkd=c^k=prmmloq=molar`qp A9 Application The RACO 7120, and 7120-1 are premium boxes for rugged new work, old work ceiling fan and fixture installations The 7120, and 7120-1 are made of heavy-duty engineered

More information

Youngstown State University

Youngstown State University SECTION 260533 - RACEWAYS PART 1 - GENERAL SUMMARY A. This section includes raceways for electrical wiring. Types of raceways in this section include the following: 1. Flexible metal conduit 2. Liquid

More information

Perfect integration! >>> FLOOR BOXES. NEW floor boxes

Perfect integration! >>> FLOOR BOXES. NEW floor boxes FLOOR OXES >>> NEW floor boxes Perfect integration! Legrand provides equipment for your raised floors and concrete floor slabs. The floor boxes blend in with the decor and their ergonomic design is tailored

More information

8461C 4SQ, 1"RSD Rndopnw/Ers CVR

8461C 4SQ, 1RSD Rndopnw/Ers CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SQ, 1"RSD Rndopnw/Ers CVR Appleton/Oz Gedney Catalog Number Manufacturer Appleton/Oz Gedney Description Steel Square

More information

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz

More information

2.7 IN-CARPET WIREWAY

2.7 IN-CARPET WIREWAY 2.7 IN-CARPET WIREWAY SUBTLE, ACCESSIBLE CONNECTIVITY Connectrac 2.7 In-Carpet Wireways. These wireways are Connectrac s lowest and sleekest. A removable wireway cap along the entire length allows easy

More information

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES 04 05 PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Over floor trunking 0 300 9 0 300 93 0 38 00 Conform to standard EN 50085-- For creating a link between trunking, column,

More information

Ruff-IN pre-fab systems

Ruff-IN pre-fab systems Fasteners RUFFIN-17 B-LINE SERIES Ruff-IN pre-fab systems Telescoping brackets Completely adjustable, fits a range of stud spacing Mounts 1 1 2", 2 1 8", 2 1 2", and 2 13 16" deep boxes Increased rigidity

More information

2.7 IN-CARPET WIREWAY

2.7 IN-CARPET WIREWAY 2.7 IN-CARPET WIREWAY U.S. List Pricing SUBTLE, ACCESSIBLE CONNECTIVITY Connectrac 2.7 In-Carpet Wireways. These wireways are Connectrac s lowest and sleekest. A removable wireway cap along the entire

More information

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Knockout Location Knockout Size 4SSPLDR

More information

PROJ. NO SECTION WIRING DEVICES

PROJ. NO SECTION WIRING DEVICES SECTION 26 27 26 WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

Big 52 cubic inch capacity. S3-52-W 3 Gang Old Work Box shown with Divider Plate, LVDIV-1

Big 52 cubic inch capacity. S3-52-W 3 Gang Old Work Box shown with Divider Plate, LVDIV-1 Quick/Click feature secures devices quickly and easily. Does not strip when over-torqued. See Page P-14 for details. 4 Auto/Clamps on each end eliminate the need for separate cable clamps. See Page P-14

More information

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure Notice: If you are using MasterFormat 2004 Edition, the proper section number to use is Section 09 69 00, Access Flooring, which appears below. If you are continuing to use MasterFormat 1995 Edition, the

More information

Deliver Long-Lasting Protection With the Most Versatile Weatherproof Covers on the Market

Deliver Long-Lasting Protection With the Most Versatile Weatherproof Covers on the Market Deliver Long-Lasting Protection With the Most Versatile Weatherproof Covers on the Market Intermatic.com Our durable lineup of die-cast, low-profile and plastic weatherproof covers offers rugged protection

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0528 Pathways. Page 1 of 6

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0528 Pathways. Page 1 of 6 1 General 1.1 Scope of work 1.1.1 The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the completion of

More information

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available. Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon

More information

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS SECTION 16711-27 05 28.33 PART 1 - GENERAL 1.01 SUMMARY A. This section includes Labor, materials and equipment necessary to complete the installation required for the items specified under this Section,

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, cabinets, and track busway for electrical wiring.

More information

FREQUENTLY ASKED QUESTIONS

FREQUENTLY ASKED QUESTIONS FREQUENTLY ASKED QUESTIONS Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND

More information

SECTION HORIZONTAL CABLING

SECTION HORIZONTAL CABLING PART 1 - GENERAL 1.1 SUMMARY SCOPE OF WORK SECTION 25160 HORIZONTAL CABLING 1. Horizontal cabling is the portion of the cabling system that extends from the work area to the Telecommunications Room or

More information

U-SERIES INSTALLATION

U-SERIES INSTALLATION U-SERIES INSTALLATION Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND LISTED

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section Data System Page 1 of 7

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section Data System Page 1 of 7 Issued 2006/08/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment

More information

SECTION LIGHTNING PROTECTION SYSTEM

SECTION LIGHTNING PROTECTION SYSTEM SECTION 16670 - LIGHTNING PROTECTION SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Q-FLOOR/TAPROUTE SYSTEM (GKX with Tapmate V) March 2008

Q-FLOOR/TAPROUTE SYSTEM (GKX with Tapmate V) March 2008 Q-FLOOR/TAPROUTE SYSTEM (GKX with Tapmate V) March 2008 PART 1: GENERAL 1.01 SCOPE Furnish the complete structural/electrical steel floor system. Work includes, but is not necessarily limited to, the following

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, and cabinets for electrical wiring. B. See Division

More information

Tate Access Floors, Inc. ConCore 1000 Access Floor Panel PosiLock Understructure

Tate Access Floors, Inc. ConCore 1000 Access Floor Panel PosiLock Understructure Tate Access Floors, Inc. ConCore 1000 Access Floor Panel PosiLock Understructure Notice: If you are using MasterFormat 2004 Edition, the proper section number to use is Section 09 69 00, Access Flooring,

More information

Tate Access Floors, Inc. ConCore 1500 Access Floor Panel PosiLock Understructure

Tate Access Floors, Inc. ConCore 1500 Access Floor Panel PosiLock Understructure Tate Access Floors, Inc. ConCore 1500 Access Floor Panel PosiLock Understructure Notice: If you are using MasterFormat 2004 Edition, the proper section number to use is Section 09 69 00, Access Flooring,

More information

onlinecomponents.com

onlinecomponents.com FSPDB FSPDB IP20 Finger Safe Power Distribution Block Reference Designation Nb. wire Nb. wire Materials Pckg inlets outlets X232803C FSPDB4A 335A 1/1 16 to 185mm 2 1x 185mm 2 to 16mm 2 1x 185mm 2 to 16mm

More information

Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System

Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System SECTION 10270 PART 1 - GENERAL 1.1 Section Includes A. Work of this section includes, but is not

More information

Compact Module. Enhanced Category 5 FTP Cabling System

Compact Module. Enhanced Category 5 FTP Cabling System Compact Module Enhanced Category 5 performance Suitable for Gigabit Ethernet Ultra-slimline design Euro style module Interchangeable with other Euro modules and blanks Individually QA tested Easy to use

More information

Basis Headwall System Design and Planning Guide

Basis Headwall System Design and Planning Guide Basis Headwall System Design and Planning Guide Table of Contents At a Glance 4 Configuring the Basis Headwall 5 Basis Headwall System Architecture Basis Horizontal Units 7 Basis Vertical Units 8 Single

More information

INSTALLATION MANUAL PROVIDER PLUS

INSTALLATION MANUAL PROVIDER PLUS INSTALLATION MANUAL PROVIDER PLUS OVERVIEW The Provider Plus is a UL-listed, surface-mounted, horizontal modular headwall assembly. This system uses one or more horizontal component tiers to locate services

More information

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING

CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING CONSTRUCTION STANDARDS SECTION CS 15 STREET LIGHTING CS 15-0l SCOPE: Street Lighting improvements shall be constructed in conformance with Section 86, Signals, Lighting and Electrical Systems, of the CALTRANS

More information

LIVE WORK PLAY LOBBY TO ROOFTOP SOLUTIONS FOR MIXED-USE BUILDINGS. designed to be better.

LIVE WORK PLAY LOBBY TO ROOFTOP SOLUTIONS FOR MIXED-USE BUILDINGS. designed to be better. LIVE WORK PLAY LOBBY TO ROOFTOP SOLUTIONS FOR designed to be better. BRING SOPHISTICATION, EFFICIENCY AND CONVENIENCE TO EVERY SPACE. PRESENT MORE THAN ONE SET OF APPLICATION CHALLENGES. CREATING A DESIRABLE

More information

I-SERIES INSTALLATION

I-SERIES INSTALLATION I-SERIES INSTALLATION Connectivity with flexibility For more product information visit connectrac.com, call us at 877-480 - 5637 or email us at info@connectrac.com ADA COMPLIANT - U.L. TESTED AND LISTED

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 16060 Grounding and Bonding This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

SECTION UNDER-CABINET LIGHTING SYSTEM

SECTION UNDER-CABINET LIGHTING SYSTEM PART 1 - GENERAL 1.1 CONDITIONS AND REQUIREMENTS SECTION 26 51 13.13 UNDER-CABINET LIGHTING SYSTEM A. The General Conditions, Supplementary Conditions, and Division 01 General Requirements apply. 1.2 SECTION

More information

Raceway and Boxes for Electrical Systems Page 1 of 7

Raceway and Boxes for Electrical Systems Page 1 of 7 Last Update: May 12, 2017 A. Conduits: Page 1 of 7 1. All conductors for each and every electrical system shall be installed in a raceway except communications and A/V systems which shall have stubs to

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section includes the following: 1. Receptacles,

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION MAY 18, 2009 SECTION COMMUNICATIONS

RESEARCH AND TECHNOLOGY BUILDING RENOVATION MAY 18, 2009 SECTION COMMUNICATIONS SECTION 27 00 00 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following items for wiring systems used as signal pathways for voice and highspeed data transmission: 1. Communication outlets.

More information

QTY 7/374 8/346 11/375 12/348 17/298 18/324 19/ / /472 24/473 3 QTY

QTY 7/374 8/346 11/375 12/348 17/298 18/324 19/ / /472 24/473 3 QTY PAGE 20 BUTT SPLICES - COPPER Produced from high conductivity seamless copper tubing Marked with die index and color coded Tin plated to provide corrosion resistance SC SERIES Standard Barrel 5808 SC 8

More information

CUSTOM PRODUCTS & SERVICES, INC. PH: FAX: WEBSITE:

CUSTOM PRODUCTS & SERVICES, INC. PH: FAX: WEBSITE: INTEGRATED CABLE MANAGEMENT SYSTEM FOR OFFICES, CLASSROOOMS, MEDIA CENTERS, MANUFACTURING FACILITIES, 911 CENTERS, DISPATCH ROOMS, CONTROL ROOMS DISTRIBUTED BY CUSTOM PRODUCTS & SERVICES, INC. PH: 888-444-1202

More information

BRCJ SPRG Cable Support. Material, Color, and Finish. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

BRCJ SPRG Cable Support. Material, Color, and Finish. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com BRCJ SPRG Cable Support Cooper B-Line/Cable Tray Catalog Number Manufacturer Description

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

TOP CAP Snaps into bottom track Aluminum - trimmed to length. RAMPS Covered by carpet ABS plastic and MDF QUESTIONS? CALL US AT !

TOP CAP Snaps into bottom track Aluminum - trimmed to length. RAMPS Covered by carpet ABS plastic and MDF QUESTIONS? CALL US AT ! IN-CARPET WIREWAY INSTALLATION GUIDE 2.7 These components are typical for each wireway installation: WALL BASE TRIM Finishes cable opening at wall BOTTOM TRACK Screws to concrete Aluminum - trimmed to

More information

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O. Siemens, Model # SUAS877-PG (or Landis & Gyr # UAS877-PG) Eaton-Durham Model # UTRS223ACH Milbank Midwest Model # U980-O UTRS223AMEP These are some examples of the single meter sockets we require for underground

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Catalog Number. Notes

Catalog Number. Notes Catalog Number FEATURES & SPECIFICATIONS INTENDED USE The " Wafer TM LED recessed downlight with remote driver box combines high quality light output and efficiency while eliminating the housing for competitive

More information