Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

Size: px
Start display at page:

Download "Insulation for VRF/VRV HVAC Systems. Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs"

Transcription

1 Insulation for VRF/VRV HVAC Systems Variable Refrigerant Flow(VRF) and Variable Refrigerant Volume(VRV) System Insulation Needs

2 Well Sealed, Skill/Detail High Level of Craftsmanship Complete Insulation Envelope All Parts Installation Longevity High Volume of Small Pipe Sizes, Thick Walls Unique Fitting Configurations Higher Service Temperature Excellent Moisture Resistance Flexibility Non-Corrosive Resistance to Weathering Superior Fire Resistance Sustainable Construction VRF/VRV System Insulation Installation Needs

3 VRF/VRV Systems Condensate Drain and Refrigeration Piping Insulation Requirements Manufacturer Service Upper Service Temperature Lower Service Temperature Thickness, Minimum Thickness, Maximum Types Mentioned Carrier(Toshiba) Cond. Drain N/A N/A.4" N/A Polyethylene Refrigerant Pipe 248 F N/A N/A N/A -- Local Code N/A Daikin Cond. Drain NONE NONE NONE NONE NO MENTION Refrigerant Pipe 248 F 30 F 1/2", 3/4" Conflicts N/A -- Local Code Fiberglass, Poly Fujitsu Cond. Drain NO MENTION NO MENTION NO MENTION NO MENTION NO MENTION Refrigerant Pipe 248 F 3/8" 1" LG Cond. Drain N/A N/A N/A N/A As Necessary Refrigerant Pipe 248 F/227 F -4 F 1/2" 1" Closed-Cell/EPDM Mitsubishi Cond. Drain N/A N/A 3/8" N/A Polyethylene Refrigerant Pipe 212 F N/A 3/8", 1/2" 3/4" or more Fiberglass, Poly Samsung Cond. Drain NON-SPECIFIC N/A N/A N/A NON-SPECIFIC Refrigerant Pipe 248 F N/A 3/8" 1-1/2" EPDM Toshiba Cond. Drain N/A N/A.4" Polyethylene Refrigerant Pipe 248 F N/A N/A N/A -- Local Code N/A Trane(Samsung) Cond. Drain NON-SPECIFIC N/A N/A N/A NON-SPECIFIC Refrigerant Pipe 248 F N/A 3/8" 1-1/2" EPDM VRF/VRV Manufacturers Insulation Requirements

4 VRF System Insulation Code Requirements

5 Piping insulation. All piping serving as part of a heating or cooling system shall be thermally insulated in accordance with Table Exceptions: 1. Factory-installed piping within HVAC equipment tested and rated in accordance with a test procedure referenced by this code. 2. Factory-installed piping within room fancoils and unit ventilators tested and rated according to AHRI 440 (except that the sampling and variation provisions of Section 6.5 shall not apply) and 840, respectively. 3. Piping that conveys fluids that have a design operating temperature range between 55 F (13 C) and 105 F (41 C). 4. Piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. 5. Runout piping not exceeding 4 feet (1219 mm) in length and 1 inch (25 mm) in diameter between the control valve and HVAC coil. NOMINAL PIPE DIAMETER FLUID 1.5 > 1.5 Steam 1-1/2 3 Hot water 1-1/2 2 Chilled water Brine Refrigerant 1-1/2 1-1/2 VRF/VRV Systems Insulation International Energy Conservation Code 2009

6 Piping insulation. All piping serving as part of a heating or cooling system shall be thermally insulated in accordance with Table Exceptions: 1. Factory-installed piping within HVAC equipment tested and rated in accordance with a test procedure referenced by this code. 2. Factory-installed piping within room fan-coils and unit ventilators tested and rated according to AHRI 440 (except that the sampling and variation provisions of Section 6.5 shall not apply) and 840, respectively. 3. Piping that conveys fluids that have a design operating temperature range between 60 F (15 C) and 105 F (41 C). 4. Piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. 5. Strainers, control valves and balancing valves associated with piping 1 inch (25mm) or less in diameter Fluid Operating Temperature Range and Usage ( F) TABLE C MINIMUM PIPE INSULATION THICKNESS ( in inches) a,c Conductivity Btu in./(hr. ft 2 F) b Insulation Conductivity Mean Rating Temperature F < 1 Nominal Pipe or Tube Size (inches) < 1 to 1-1/2 1-1/2 to < 4 > < to < 8 > 8 International Energy Conservation Code 2015

7 Copper Aluminum Flexible Composite Copper Line Set VRF/VRV Piping Systems

8 Corrosion Under Insulation(CUI) External Stress Corrosion Cracking(ESCC)

9 How Does CUI and ESCC Happen? Corrosion Under Insulation usually results from the ingress of water (or other types of corrosive solvents) into the insulation Insulation can contain corrosive chemicals which turn to acidic substances, especially under heat or combustion. Microorganisms can cause microbial corrosion. Some microorganisms oxidize iron into iron oxides or iron hydroxides, forming rust. Some microorganisms emit chemically-polar acids that damage both metal surfaces and the insulation itself. Contaminants in the plant environment can accelerate corrosion. Corrosion Under Insulation(CUI) External Stress Corrosion Cracking(ESCC)

10 How To Avoid CUI and ESCC Design, install, and maintain insulation systems to minimize ponding water or penetration of water into the system. Insulation should be appropriate for its intended application and service temperature. The insulation characteristics with the most influence on CUI are: (1) water-leachable salt content in insulation -- chloride, sulfate, and acidic materials in fire retardants and processing aids (2) water retention, permeability, and wettability of the insulation (3) foams containing residual compounds that react with water to form hydrochloric or other acids. Corrosion Under Insulation(CUI) External Stress Corrosion Cracking(ESCC)

11 MATERIAL PROPERTY Aerocel EPDM PIR Phenolic NBR/PVC Fiberglass Polyethylene PUBLISHED DATA Thermal Conductivity / Upper Service Temp. 257 F/300 F 300 F 257 F 180 F/220 F 850/1000 F 190 F Lower Service Temp -297 F -297 F -297 F -297 F 0 F -330 F Water Vapor Perm /.08 Unlimited 0.02 Water Absorbtion <.2% <.7% 0.9% 0.2% UNKNOWN UNKNOWN Flame/Smoke 25/50 25/450 25/50 25/50 25/50 25/50 Self-Extinguishing Y N N N UNKNOWN N Significant HCN/HCl N/N Y/Y Y/Y Y/Y N/N N/N Weather/UV Resistant Y N N N N N Additional Finishes N Y Y Y Y Y Close Cell Content 100% 90% 95% 92% 0 100% Flexibility Y N N Y N SEMI Corrosiveness N Y Y Y Y UNKNOWN ID's 1/4" - 16" 1/4" - 12" 1/4" - 12" 1/4" - 8" 5/8"- 30" 3/8" - 4" Thickness 3" 6" 6" 2" 3" 1" MAX VRF Insulation Material Comparisons

12 No or Improper Seam Closure No or Poor Fitting Insulation Don t SLIDE! No or Poor Anchoring Device (Hanger) Insulation Stretching Insulation No Spacing Between Pipes No Vapor Stopping Improper Termination at Equipment No Protective Finish When Required VRF System Insulation Biggest Failure Points

13 No or Improper Seam Closure VRF/VRV Insulation System Biggest Problems/Failures

14 No or Poor Fitting Insulation Don t SLIDE! VRF/VRV Insulation System Biggest Problems/Failures

15 No or Poor Anchoring Insulation Improper Support at Anchor Locations Tight Pipe Rack Spacing VRF/VRV Insulation System Biggest Problems/Failures

16 Support at Hangers ASHRAE Handbook of Fundamentals, Chapter 23 Mechanical Insulation When avoiding compression of low compressive-strength insulation products is the goal, it is recommended that highstrength insulation inserts, made of a product that offers the desired compressive strength and other necessary performance properties, be used. Note that the old method of using wood blocks instead of a high strength insulation insert is not recommended, especially for cold pipe systems. Other higher strength materials that are not thermal insulation material and interrupt the insulation envelope, or do not allow complete sealing of an insulation system against water vapor ingress, are not recommended for the support of insulated piping on pipe hangers. Piping Support

17 No Protective Finish When Required VRF/VRV Insulation System Biggest Problems/Failures

18 BEST K-Value at 0.245; Deliver Lower Energy Costs than Others BEST UV Resistance; Save on First Cost and Long Term Ownership Cost BEST Self-Sealed System (SSPT with Cel-Link II); Reduce Installation Costs, Gets Projects Done, Meets LVOC Needs BEST Water Vapor Transmission Rate (WVTR),.03 Perms; Maintain Energy Savings, Avoids Mold Growth, Enhances System Life BEST Service Temperature for ASTM C 534 Type I Grade 1, +257 F (300 F Non-SSPT); Widest Range of Applications Superior Fire Safety Properties; Meets and exceeds life safety requirements Stays Flexible in Cold Weather; Keep Job Costs in Check, Keep Installers Working Low Halogens Content; Avoid Cost from External Stress Corrosion Cracking (ESCC) on Stainless Steel or Copper Tubing The Aerocel Oranges Advantages of EPDM Insulation

19 NBR/PVC = Polar Material (Atomically Charged) Less Stable Deteriorates with the application of energy through: - Chemical reaction -- As with water, ozone, or other solvents - Heat energy As applied by mechanical systems or environment - Light Energy UV light highly detrimental EPDM = Non-Polar Material (Atomically Neutral) Highly Stable No reactivity because of balanced atomic structure Polar vs. Non-Polar (NBR/PVC vs. EPDM)

20 Wall Thicknesses 3/8, ½, ¾, 1, 1-1/2, 2 ID Range ¼ ID through 16 ID ASHRAE Cooling Mostly 1 thick, Some ½ Heating 1-1/2 and 2-1/2 Thick IECC /2 Thick for All Building Space Conditioning Refrigeration Piping, including Heating Mode IECC 2012/2015 Cooling Mostly 1 thick, Some ½ Heating 1-1/2 and 2-1/2 Thick Aerocel EPDM Elastomeric is Supplied in the Best Size Offering

21 Aerocel AC and Aerocel SSPT with Cel-Link II(Video) Aerofix -U AeroFit Aeroseal Adhesive Protape Aerocel with SaniGuard VRF System Insulation Installation Solutions

22 The Hermetic System EPDM-BASED HIGH-PERFORMANCE AEROCEL Sealed Including PROPER Vapor Stopping No Compression Correct Anchoring No Sliding Fittings ID/Thicknesses Non Corrosive VRF/VRV Key Points Of Installation

23 Thank You for Your Time Aerocel The Right Elastomeric Insulation for VRF/VRV Systems

Tube Insulation. Fiber Free

Tube Insulation. Fiber Free Fiber Free Tube Insulation Fiber-free, flexible, elastomeric pipe insulation for reliable protection against condensation, mold, energy loss and ultraviolet radiation in residential and commercial applications

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

PRODUCT SELECTION GUIDE

PRODUCT SELECTION GUIDE Fiber Free PRODUCT SELECTION GUIDE Quick guide for selecting fiber-free, mold-resistant mechanical insulation from the makers of Armaflex GREENGUARD Certified products are certified to GREENGUARD standards

More information

Redi-Klad 1000 Pipe Insulation

Redi-Klad 1000 Pipe Insulation Knauf Data Sheet PE-DS-16e 12-09 Redi-Klad 1000 Pipe Insulation with ECOSE Technology Knauf Redi-Klad 1000 F Pipe Insulation with ECOSE Technology is offered across a wide range of sizes. For iron pipe

More information

SECTION PIPING INSULATION

SECTION PIPING INSULATION SECTION 23 07 19 PIPING INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Piping insulation for refrigerant piping within building envelope. 2. Furnishing and installation of insulation.

More information

Ammonia. Product performance for insulation of ammonia piping

Ammonia. Product performance for insulation of ammonia piping Ammonia Product performance for insulation of ammonia piping ABOUT K-FLEX USA K-FLEX USA IS A LEADING MANUFACTURER of flexible, closed cell elastomeric insulation for mechanical piping, air handling units

More information

Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems

Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems Solving Corrosion Under Insulation Utilizing FOAMGLAS Cellular Glass Insulation Systems NACE International Jubail, Kingdom of Saudi Arabia November 30, 2010 Steven T. Oslica Director of Marketing FOAMGLAS

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

HVAC Piping Insulation- FIBERGLAS Insulation

HVAC Piping Insulation- FIBERGLAS Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Corrosion Under Insulation (CUI) and the Insulation System. By Soeren Nyborg Rasmussen ROCKWOOL Technical Insulation, Jubail, 10 December 2015

Corrosion Under Insulation (CUI) and the Insulation System. By Soeren Nyborg Rasmussen ROCKWOOL Technical Insulation, Jubail, 10 December 2015 Corrosion Under Insulation (CUI) and the Insulation System By Soeren Nyborg Rasmussen ROCKWOOL Technical Insulation, Jubail, 10 December 2015 The issue Corrosion of steel occurs in the presence of water

More information

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product Techna-Duc Advantages Techna-Duc is shop fabricated and installed with minimal field alterations. Panels are constructed with polyisocyanurate insulation products that do not promote the growth of mold

More information

Mechanical Insulation for Refrigeration Systems

Mechanical Insulation for Refrigeration Systems Mechanical Insulation for Refrigeration Systems INDUSTRIAL REFRIGERATION CONSORTIUM RESEARCH & TECHNOLOGY FORUM MAY 2-3, 2012 Peter Gauchel, President/CEO L&C Insulation Inc. Overview Current trends in

More information

CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE

CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE CUI (CORROSION UNDER INSULATION) MECHANISM THEORY AND PRACTICE Prepared By: Mohammed AbuALRub SAFCO Reliability Dept. December 10, 2015 CONTENT Introduction CUI PhenomenaMain components of the cold insulation

More information

GREEN THREAD Piping Systems

GREEN THREAD Piping Systems Bulletin No. A1300 February 15, 2006 SMITH FIBERCAST GREEN THREAD Piping Systems PRODUCT GREEN THREAD pipe is filament wound using an amine cured epoxy resin and fiberglass and has a resin-rich liner reinforced

More information

Resource Guide. Section 4: Ni-Resist

Resource Guide. Section 4: Ni-Resist Resource Guide Section 4: Ni-Resist Section 4 Ni-Resist Description of Grades... 4-3 201 (Type 1) Ni-Resist... 4-4 202 (Type 2) Ni-Resist... 4-6 Stock Listings... 4-8 4-2 Ni-Resist Description of Grades

More information

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER Dyplast Products Copyright 2012 1 Rev 0112 DYPLAST PRODUCTS

More information

STAINLESS STEEL SHEETS

STAINLESS STEEL SHEETS STAINLESS & NICKEL ALLOY CHATHAM STEEL CORPORATION 59 STAINLESS STEEL SHEETS TYPE 04, 04L, 6, 6L No. 2B Finish Cold Rolled, Annealed *No. 2D Finish No. Finish Polished One Side No. 4 Finish Polished One

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

TECHNICAL BULLETIN POLYISOCYANURATE VS. CELLULAR GLASS IN LOW TEMPERATURE MECHANICAL INSULATION

TECHNICAL BULLETIN POLYISOCYANURATE VS. CELLULAR GLASS IN LOW TEMPERATURE MECHANICAL INSULATION TECHNICAL BULLETIN 0114 1 POLYISOCYANURATE VS. CELLULAR GLASS IN LOW TEMPERATURE MECHANICAL INSULATION PURPOSE This Technical Bulletin is an update in our series of white papers aimed at providing our

More information

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3089 Reissued 07/2016 This report is subject to renewal 07/2018. DIVISION: 07 00

More information

Smart Vapor Retarders

Smart Vapor Retarders CertainTeed Smart Vapor Retarders Insulation B UILDING S CIENCE SMART VAPOR RETARDERS: A TECHNOLOGY PRIMER For years, builders have relied on a dual climate-zone classification for the placement of vapor

More information

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1504 Reissued 03/2017 This report is subject to renewal 03/2018. DIVISION: 07 00

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 23 07 00 - SYSTEM INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section 23 01 00, "Mechanical

More information

EFRIGERATION INSTALLATION GUIDE

EFRIGERATION INSTALLATION GUIDE R EFRIGERATION INSTALLATION GUIDE Golden Rules for Working with INSTALLATION Armaflex and good adhesive brushes1 fittings. mitered fabricated Use good quality tools and, in particular, fresh 520, 520 Black

More information

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe Plastic Pipe Materials, Joining, Installation, & Other Considerations Some of the pipe that you may see? Around the late 1950 s to early 2000 s Thermoplastics Plastic Materials Must Meet: ASTM D-2513 (Thermoplastic)

More information

Chapter 2: Foundation

Chapter 2: Foundation Chapter 2: Foundation Crawlspace [V502.1.2] [V502.1.2] [V502.1.3] Vents. Vents in the crawlspace help keep floor insulation and floor framing dry. Crawlspace vents also reduce the potential for radon buildup

More information

MAKE ROOFS LAST LONGER

MAKE ROOFS LAST LONGER MAKE ROOFS LAST LONGER Roof Coatings & Roof Repair Single-Ply Metal Asphalt HIGHEST PERFORMING SYSTEMS. LOWEST APPLIED COST. METAL ROOF RESTORATION Metal Restoration Quick Guide Acrylic Polyurethane High

More information

Thermal Bridging in Residential Construction

Thermal Bridging in Residential Construction PHRC Webinar Series Tuesday, May 12, 2015 @ 1pm Thermal Bridging in Residential Construction Brian Wolfgang Housing Systems Specialist Pennsylvania Housing Research Center 219 Sackett Building University

More information

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3914 Reissued 10/2017 This report is subject to renewal 10/2018. DIVISION: 07 00

More information

Alloy C194 vs. Alloy C122 for Air Conditioning and Refrigeration Applications

Alloy C194 vs. Alloy C122 for Air Conditioning and Refrigeration Applications Fineweld Tube TECHNICAL LETTER Alloy C194 vs. Alloy C122 for Air Conditioning and Refrigeration Applications Connection tube is an important element in a refrigeration/air conditioning system transmitting

More information

2013 COMMERCIAL PRODUCTS

2013 COMMERCIAL PRODUCTS 2013 COMMERCIAL PRODUCTS EXPLORE GEOMETRY AND SPACE WITHOUT COMPROMISING BUILDING ENVELOPE PERFORMANCE Commercial design considerations come with very specific challenges that can t be addressed with just

More information

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. DIVISION 04 MASONRY 04720 CAST STONE A. Design Considerations 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. 2. Care must be taken in the design of individual units

More information

CORROSION UNDER INSULATION (CUI) A Nanotechnology Solution. Explanation:

CORROSION UNDER INSULATION (CUI) A Nanotechnology Solution. Explanation: CORROSION UNDER INSULATION (CUI) A Nanotechnology Solution Explanation: Corrosion is the deterioration of essential properties in a metal, due to reactions with its surroundings. In the most common usage

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100) ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 15 2006 (Formerly IPS SP 100) Specification for Trunk, Feeder and Distribution Coaxial Cable NOTICE The Society

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER: 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 2717 Reissued 07/2015 This report is subject to renewal 07/2017. DIVISION: 07 00 00 THERMAL

More information

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction WHAT IS PLY-FOIL? Ply-Foil is a multilayer, reflective insulation which comes in rolls consisting

More information

Cryogenic Pipe Support Systems

Cryogenic Pipe Support Systems Cryogenic Pipe Support Systems Overview Rilco cryogenic pipe supports are developed to support cold piping in various applications ranging from chilled water to liquefied natural gas. The qualified service

More information

W ater T alk. Field Corrosion Testing using Coupons

W ater T alk. Field Corrosion Testing using Coupons W ater T alk Field Corrosion Testing using Coupons Volume 12, Issue 1 April 2012 Most Cooling Water systems are continuously in use. Therefore it is rare to have access to inspect the actual system to

More information

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL).

Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL). Best Practice Recommendations for Wall Retrofit on the Two-Story Flexible Research Platform (FRP) at Oak Ridge National Laboratory (ORNL). Wall retrofit strategies for retrofit on the interior side of

More information

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

TSX Insulation for Exposed Use ROOF WALL SPECIALTY Insulation for Exposed Use ROOF WALL SPECIALTY PRODUCT DESCRIPTION Rmax TSX-8500 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (Polyiso) foam core bonded to

More information

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000

More information

Mechanical Product Overview

Mechanical Product Overview Mechanical Product Overview The founding principles of Price have never changed business integrity, first class service, innovation and a commitment to people. PURPOSE BUILT FOR YOUR APPLICATION Whether

More information

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457)

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457) FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457) 861611 INDUSTRIAL INSULATION Kingspan Industrial Insulation Limited PO Box

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC 0 ICC ES Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3210 Valid: 03/15 to 03/16 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21

More information

Bulletin No. A1380 September 15, Smith Fibercast CENTRICAST PLUS RB-2530 Piping Systems

Bulletin No. A1380 September 15, Smith Fibercast CENTRICAST PLUS RB-2530 Piping Systems Bulletin No. A1380 September 15, 2005 Smith Fibercast CENTRICAST PLUS RB-2530 Piping Systems PRODUCT CENTRICAST PLUS RB-2530 pipe is manufactured with high strength glass fabrics and our highly resilient

More information

The Building Envelope Solution. Mike Lowery A&D Products, LLC

The Building Envelope Solution. Mike Lowery A&D Products, LLC The Building Envelope Solution Mike Lowery A&D Products, LLC Provider # K031 Course # CCM121 The industries ONLY single-source material performance and tie-in warranty for all 6 sides of your building!

More information

MuShield s High Permeability Magnetic Shielding per ASTM A753 Alloy Type 4

MuShield s High Permeability Magnetic Shielding per ASTM A753 Alloy Type 4 MuShield s High Permeability Magnetic Shielding per ASTM A753 Alloy Type 4 Available in coil, sheet, rod, billet, wire, and bar form, MuShield s High Permeability Magnetic Shielding is a soft magnetic

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Single-Jacketed Tubing

Single-Jacketed Tubing Single-Jacketed Tubing COILED STICK CUT TO LENGTH UTC Single Jacketed tube Protect the tube against corrosion and pitting in a diverse changing environment and climates. The phenomenon of Chloride Stress

More information

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D PIPEWORK INSULATION 14/10-2014 Page 1 of 10 Pipework Insulation Rev D Contents INTRODUCTION General Scope Surfaces to be Insulated Pumps, Turbines etc Performance Minimum Pipe Insulation Thickness Physical

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS) 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3662 Reissued 05/2017 This report is subject to renewal 02/2019. DIVISION: 07 00

More information

Insulation Board. Knauf Data Sheet PE-DS

Insulation Board. Knauf Data Sheet PE-DS Insulation Board Knauf Data Sheet PE-DS-2 12-06 Insulation Board Description Knauf Insulation Board is a thermal and acoustical insulation product made from inorganic glass fibers preformed into boards

More information

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology

Knauf Data Sheet PE-DS-2e Insulation Board. with ECOSE Technology Knauf Data Sheet PE-DS-2e 8-09 Insulation Board with ECOSE Technology Insulation Board with ECOSE Technology Description Knauf Insulation Board with ECOSE Technology is a thermal and acoustical insulation

More information

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8

Chapter 2. Basic practices. Topics. 7 Basic practices. Notes. 2.5 Existing flooring and adhesive residue Job site conditions 8 7 Basic practices Chapter 2 Basic practices Topics 2.1 Job site conditions 8 2.2 Wood subfloors 9 2.3 Concrete subfloors 10 2.5 Existing flooring and adhesive residue 11 2.6 Radiant heat subfloors 11 2.7

More information

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m.

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m. Air Source Heat Pumps in the Commercial Market Thursday, February 5, 2015 9:00-10:30 a.m. 1. Commercial Equipment Applications, Benefits, Limitations 2. Case Studies 3. Efficiency Vermont Technical & Financial

More information

Crawl Space Moisture Control

Crawl Space Moisture Control Crawl Space Moisture Control Crawl space foundations are found in many homes. Typically, these foundation types are equipped with operable vents designed to provide ventilation for moisture control. Unfortunately,

More information

Lifetime Guaranteed Construction with unique built-in installation and maintenance features

Lifetime Guaranteed Construction with unique built-in installation and maintenance features Lifetime Guaranteed Construction with unique built-in installation and maintenance features Great Basin grease interceptors provide the best in quality materials and engineered craftsmanship. Units are

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2100 Reissued 02/2017 This report is subject to renewal 02/2018. DIVISION: 07 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts Peter Kalinger Canadian Roofing Contractors Association Dr. B. Baskaran National Research Council of Canada 1 Air Leakage Controlling

More information

PIP INSC1000 Cold Service Insulation Materials and Installation Specification

PIP INSC1000 Cold Service Insulation Materials and Installation Specification COMPLETE REVISION Ocber 2017 Insulation PIP Cold Service Insulation Materials and Installation Specification PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort minimize the cost of process industry

More information

Price Single Duct Terminal Units

Price Single Duct Terminal Units Price Single Duct Terminal Units Division 23 Heating, Ventilating, and Air Conditioning Section 23 36 00 Air Terminal Units The following specification is for a defined application. Price would be pleased

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

Earthwool 1000 Pipe Insulation

Earthwool 1000 Pipe Insulation Data Sheet CI-PE-DS 12-15 Earthwool 1000 Pipe Insulation with ECOSE Technology Knauf Insulation Earthwool 1000 pipe insulation is a molded, heavydensity, one-piece insulation made from inorganic glass

More information

TOPCOAT Product Catalog

TOPCOAT Product Catalog TOPCOAT Product Catalog (TOPGN235) Updated: 7/14 gaf.com TOPCOAT L I Q U I D-APPL IED R O O F I N G gaf.com Energy-Saving Liquid-Applied Roofing Solutions! FEWER COATS FEWER GALLONS FEWER LABOR HOURS BIGGER

More information

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,

More information

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT Specification for Acoustical Insulation (Lagging) for Piping and Equipment 1 of 5 TABLE OF CONTENTS 1.0SCOPE..... 3 2.0REFERENCED PUBLICATIONS...

More information

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over

More information

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2668 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 07 00

More information

TECH SOLUTIONS Hot Box Testing of Four Different Metal Building Roof Assemblies Determines Insulation Efficiency

TECH SOLUTIONS Hot Box Testing of Four Different Metal Building Roof Assemblies Determines Insulation Efficiency Summary Using the ASTM 1363, or hot box test, four different metal roofing assemblies were tested to determine their effective R-value versus the design R-value of the insulation. The ratio of these two

More information

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

PIP PCEPA003 Process Analyzer System Field Installation Guidelines January 2016 Process Control PIP PCEPA003 Process Analyzer System Field Installation Guidelines PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities,

More information

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1 Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

Distributor : DAI VIET TRADING & TECHNICAL SERVICES COMPANY.,Ltd

Distributor : DAI VIET TRADING & TECHNICAL SERVICES COMPANY.,Ltd ISOFLEX TM flexible thermal insulation pipe: Pipe size: 6-108mm Facing: pipe can be covered with aluminum foil ISOFLEX TM flexible thermal insulation pipe Overview: ISOFLEX flexible thermal insulation

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2668 Reissued 11/2017 This report is subject to renewal 11/2018. DIVISION: 07 00

More information

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 21 00 THERMAL INSULATION

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

PIMA PERFORMANCE BULLETIN Foil-Faced Polyiso and Unfaced Mineral Wool Board in Commercial Wall Applications

PIMA PERFORMANCE BULLETIN Foil-Faced Polyiso and Unfaced Mineral Wool Board in Commercial Wall Applications PIMA PERFORMANCE BULLETIN Foil-Faced Polyiso and Unfaced Mineral Wool Board in Commercial Wall Applications Foil-faced Polyiso wall insulation, when used in commercial wall applications, is one of the

More information

A. Source Limitations: Obtain each type of building insulation through one source.

A. Source Limitations: Obtain each type of building insulation through one source. SECTION 07210 - BUILDING INSULATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Metal Transitions HIGH TEMPERATURE

Metal Transitions HIGH TEMPERATURE Metal Transitions High Temperature Thermal Solutions of Texas continues to meet the demands of technological advances by developing thermocouples using materials with unusually high performance characteristics

More information

CONDUITS AND FITTINGS

CONDUITS AND FITTINGS CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit

More information

Property Condition Assessment

Property Condition Assessment Property Condition Assessment Pewaukee, WI 53072 Inspection Date: 1/6/15 Prepared For: Report Number: Prepared By: Shamrock Building Inspection Consultants LLC N29 W29951 Shel-Mar Dr. Pewaukee, WI 53072

More information

ACBC Floor Mounted Active Beam

ACBC Floor Mounted Active Beam Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS

More information

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology

Knauf Data Sheet CI-DLS-DS Sonic XP. Duct Liner. with ECOSE Technology Knauf Data Sheet CI-DLS-DS 04-14 Sonic XP with ECOSE Technology Duct Liner Sonic XP Duct Liner with ECOSE Technology Description Knauf Insulation Sonic XP Duct Liner is a flexible, mat-faced insulation

More information

CONTENTS OF THE DECLARATION. The PCR review was conducted by: 333 Pfingsten Road Northbrook, IL 60611

CONTENTS OF THE DECLARATION. The PCR review was conducted by: 333 Pfingsten Road Northbrook, IL 60611 This declaration is an environmental product declaration (EPD) in accordance with ISO 14025. EPDs rely on Life Cycle Assessment (LCA) to provide information on a number of environmental impacts of products

More information

Repair Maintenance Hangar Phase II August 2010

Repair Maintenance Hangar Phase II August 2010 SECTION 08800 GLASS AND GLAZING PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Monolithic glass. 2. Insulating glass. 3. Mirror glass. 4. Glazing accessories. B. Types of work in this section include

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

Specifications for FL-100 Soffit Panel

Specifications for FL-100 Soffit Panel Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated

More information

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition Spray Polyurethane Foam Design Guidance Insulation and Air Barrier Requirements of the 2012 I-Codes Spray Foam Coalition about the collaboration the center for the polyurathanes industry (CPI) of the

More information

CHECKLIST Inspecting a Garage

CHECKLIST Inspecting a Garage CHECKLIST Inspecting a Garage By Ben Gromicko This section deals with the details of the garage or carport inspection that may be performed. At the end of this section, you shall be able to: describe the

More information

FOAMGLAS INSULATION SPECIFICATION

FOAMGLAS INSULATION SPECIFICATION FOAMGLAS INSULATION SPECIFICATION PITTSBURGH CORNING CORPORATION FOAMGLAS Products Technical Support 800 Presque Isle Drive Pittsburgh, PA 15239 724-327-6100 SPECIFICATION # I-H/C-89-02-01 REVISION 06/28/2004

More information

Exterior Building Materials & Detailing

Exterior Building Materials & Detailing Exterior Building Materials & Detailing Marquam George Marquam George LLC Juneau, Alaska marquamgeorge@gmail.com Barriers to? V.1950 Air only Vapor only Water only Air & Water 1 V.1990 V.2005 Detailing

More information

InSoFast Outperforms R-13 Fiberglass

InSoFast Outperforms R-13 Fiberglass Engineered Insulation Panels InSoFast Outperforms R-13 Fiberglass As you will see in the charts below, InSoFast panels with a total wall assembly R-Value of 11.08 will outperform the traditional 2x4 framed

More information

Optimize to Oxidize - CPVC Weathers the Chlor-Alkali Industry s Toughest Conditions

Optimize to Oxidize - CPVC Weathers the Chlor-Alkali Industry s Toughest Conditions Optimize to Oxidize - CPVC Weathers the Chlor-Alkali Industry s Toughest Conditions Industrial-grade chlor-alkali production has been underway for more than 120 years, and in many ways, the principles

More information

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015. A Subsidiary of the International Code Council

More information

Diffused Aeration Piping Equipment

Diffused Aeration Piping Equipment 1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections

More information

Test Report. Prepared For: Mr. Simone Furiato Ebrille S.r.l Strada Canelli, 53/a Nizza Monferrato (Asti)-Italy

Test Report. Prepared For: Mr. Simone Furiato Ebrille S.r.l Strada Canelli, 53/a Nizza Monferrato (Asti)-Italy Test Report Hot Surface Performance Measurement According to ASTM C411 on Non-Cross Linked Polyethylene Foam Pipe Insulation Supplied by Ebrille S.r.l Prepared For: Mr. Simone Furiato Ebrille S.r.l Strada

More information

EVALUATION SUBJECT: WATTS RADIANTPEX, WATTS RADIANTPEX+, WATTS HEATINGPEX, AND RADIANTFLOW

EVALUATION SUBJECT: WATTS RADIANTPEX, WATTS RADIANTPEX+, WATTS HEATINGPEX, AND RADIANTFLOW ICC-ES Report PMG-1008 Reissued 12/2017 This report is subject to renewal 12/2018 EVALUATION SUBJECT: WATTS RADIANTPEX, WATTS RADIANTPEX+, WATTS HEATINGPEX, AND RADIANTFLOW DIVISION: 23 00 00 HEATING,

More information

NRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly

NRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly Introduction 2001 Company, contracted NRCC/IRC to evaluate and determine both the thermal resistance and air leakage characteristics of five roofing specimens under controlled laboratory conditions. The

More information