1 Club House and Jr. Club House Southport, Connecticut Harbor Road Southport, Connecticut Architect: Martin A. Benassi, AIA Architect Two Broadway Hamden, CT Date:

2 Table of Contents Introduction Preamble Building History Data Collection Field Testing Format Observations General Site Masonry Metal Wood Thermal and Moisture Protection Evaluations General Design Construction Materials Maintenance Miscellaneous Recommendations / Cost Estimate General Recommendations Reasons Estimated Cost of Construction Appendix A - Photos B - Drawings C - The Southport Packet, Vol. 1 No. 4 D - Cost Estimate References ASTM C270 Standard Specification for Mortar for Unit Masonry Brick Institute of America (BIA) technical notes: 7 Water Resistance of Brick Masonry Design and Detailing Part I of III 7A 7B Water Resistance of Brick Masonry Materials Part II of III Water Resistance of Brick Masonry Construction and Workmanship Part III of III Table of Contents Page 1

3 INTRODUCTION PREAMBLE A proposal was sent to Jack Fanzen, FAIA dated December 9 th, 2003 regarding performing a masonry evaluation study of the, Harbor Road, Southport, Connecticut. The proposal was accepted and a letter authorizing us to proceed was sent by C. Wesley Dunn, Jr. dated December 17 th. An initial site visit was scheduled for January 16 th to review the general scope of work. Present at that time were Jack Franzen, FAIA of Franzen Associates, Alan Pinto and Martin Benassi, AIA of Martin A. Benassi, AIA - Architect. Additional site visits were made on January 20 th and January 29 th to gather information and photos. The intent of this study is to evaluate existing masonry conditions and prepose recommendations for repair. Toward this end, several site visits were made to document existing conditions using photographs and sketches, some of which are included in this study under the appropriate appendix. This was to be a non-destructive, visual type investigation of the buildings. For this reason, no cutting or patching was necessary. Miscellaneous samples were retained for examination back at the office. They included mortar and paint chips. BUILDING HISTORY The consists of two buildings adjacent to each other known as the Club House and Jr. Club House. The Club House was built in 1886 and was known as the Old Jelliff building. The Jr. Club House was originally known as the Simon Banks building. The Club House was originally four stories. The top two stories were removed and a new gable, roof framing system was installed, resulting in a two-story structure with an attic. The building has solid masonry exterior bearing walls made of brick with wood-framed interior partitions and floor. The building footprint is approximately 39' x 80'-6" for a total of 3,150 square feet per floor. Presently the building functions as the main dining facility with storage lockers located in the attic. The Jr. Club House is of similar construction and profile. Early photos show the building as a full three stories with a flat roof. The roof was removed and a new gable, roof framing system was installed using the third floor as attic space. The building footprint is 48'-10" by 70' for a total of 3,400 square feet per floor. Presently the building functions as Men s and Ladies room and shower along with Club Manager s office. DATA COLLECTION Introduction Page 1

4 There were no drawings available of either building. Schematic drawings attached were generated from field measurements taken during site visits. They are for presentation purposes only and are not intended to be working drawings or As-built documents. Information regarding the history of the building was provided by the Pequot Library Collection (see Appendix C). FIELD TESTING FORMAT Samples of the mortar were retained for testing back at the office. Information regarding the mortar is included in the text. No other testing was conducted in the field. The survey is organized into four sections: Introduction, Observations, Evaluations, and Recommendations with Appendixes attached. This report is not for construction and was prepared for the sole use by the Owner, The of Southport, Connecticut. Any reprints or copies of this report without the written consent of the Architect or Owner is unlawful. END OF SECTION Introduction Page 2

5 OBSERVATIONS GENERAL SITE MASONRY METAL Observations Page 1 The Club House was originally four stories as noted under the Introduction / History section of this report, the top two stories having been removed. The Jr. Club House also had major upper level and roof alterations. Signs of the renovations are most noticeable along the north elevation of the Jr. Club House where silhouettes of the original third-floor windows can be seen (see photo no. 3). There were no signs of water damage to the interior surfaces, and none were reported. The buildings are situated on the site with the front (north elevation) facing Harbor Road and the porch / balcony (south elevation) facing the Southport Harbor and docks. The grade drops off towards the water. The buildings are most likely set on fill. The buildings have a stone foundation of which only 21 inches of the south portion is exposed on the Jr. Club House and 16 inches of the north elevation on the Club House. The remainder may have been covered during renovations or regrading for the parking lot and driveway. Exterior bearing walls are constructed of solid brick, three wythe thick set in a common bond with every seventh course set header. The exterior facade had been painted white and removed during power washing. This is most noticeable along the street elevation of the Club House (see photo no. 14). Some efflorescence was observed, mostly contiguous or near deteriorated masonry. There are signs that water repellant may have been applied some time in the past to the building facade. There is extensive spalling and brick deterioration at various locations on both buildings with the most severe being along the southwest corner of the Jr. Club House (see photo nos. 1 and 4). Also, areas of masonry deterioration can be seen along the watertable, at grade line, chimneys, and where water has been allowed to penetrate (see photo nos. 4, 5, 8, 9, 18, 19, 20). Masonry repairs have been made in the past including repointing and crack repair. Cracks were noted at various locations throughout the buildings, most noticeably at the corners and around fenestration (see photo nos. 10, 15, 16, 17). There are no weeps on the entire building.

6 WOOD There are steel lintels above window heads used to support the masonry above. There are signs of rusting and exfoliation of the steel (see photo no. 24). There is a steel fire escape from the second floor located along the east elevation of the Jr. Club House. Severe ice buildup has occurred on the landing and stairs causing a potential safety hazard. The stair is attached to the building and secured with expansion type anchors. Damaged masonry and deteriorated mortar were observed near the fire escape (see photo nos. 7,8). Architectural detailing of the cornice, eaves, columns, railings, window heads and miscellaneous trim are made of wood. All wood has been painted white. Some of the trim was missing on the eave of the Jr. Club House (see photo no. 6). Some peeling paint was observed at various locations (see photo no. 6). THERMAL AND MOISTURE PROTECTION Sealant around penetrations has dried out, cracked or, in some locations, is missing (see photo no. 11). No expansion or control joints were observed anywhere on the buildings. Sheet metal flashing was observed on some of the window heads, but not all. Copper flashing was observed at the tie-in of the chimney base and balcony (see photo nos. 1, 5, 20). END OF SECTION Observations Page 2

7 EVALUATIONS GENERAL Design Evaluations Page 1 In general, the buildings appear to be in good condition for their age, with the exception of some areas where the masonry has deteriorated. There is also some settlement cracking which may be related to bad soil conditions. Damage can be traced back to water penetration. Review of the Brick Institute of America (BIA) technical notes shows that successful performance of a masonry wall depends on limiting the amount of water that enters the wall system. If water penetration can be limited, for all practical purposes, the wall will remain dry. Water resistance of a masonry wall depends on four key factors: 1. Design, including detailing 2. Construction 3. Materials 4. Maintenance All four of the above criteria must be given careful attention in order to produce a satisfactory performing masonry wall. The buildings are subjected to extreme environmental conditions, such as winddriven rain and salt air, due to their proximity to the coast. Efflorescence is a result of moisture migration into the masonry, washing the salts out of the mortar where they dry onto the surface of the brick leaving the salt stain. Efflorescence is a sign that moisture is penetrating the wall and should be corrected. There are products on the market today which help to seal masonry veneers. Care must be taken in the selection and application of such sealants. The intent is to limit the amount of wind-driven rain from penetrating the masonry, while allowing vapors to pass. If the product does not allow for proper migration of the vapor through the wall, spalling of the brick surface can occur. Silicone was a product widely used in the past. It caused staining of the building exterior and trapped vapors, causing damage to the building facade. It is nearly impossible to keep a heavy, wind-driven rain from penetrating a single wythe of brick. Therefore, control of this moisture is important. However, due to the thickness of the masonry wall, one can assume that the water hasn t penetrated completely through at this time. Water that does penetrate the exterior is absorbed by the brick. Freezing temperatures will cause spalling or cracking of the brick face. Wall flashing helps to divert water that does penetrate the brick back to the exterior of the structure. This is important with respect to window and door heads where rotting of the jamb and frame would result. Flashing also protects steel lintels from rusting. Exfolliation will push the brick out while weakening the

8 steel. Construction Control joints are not necessary in a building of this size, especially with solid masonry walls. However, there is some concern over the settlement cracking which is occurring on the southwest corner of the Club House. It is not clear if this is an ongoing condition or relatively new. Crack monitors can be placed on the building bridging the gap and can be checked periodically to see if there is any movement in the building that would warrant additional investigation. The solid masonry construction is typical of this era. Common brick coursing with every seventh course set perpendicular as a header course provides the necessary ties. Materials Maintenance Evaluations Page 2 The bricks used are Type FBS, Grade SW, in accordance with ASTM C-216 Standard Specification for Facing Brick. This type of brick is acceptable for applications above grade. However, it is not acceptable for below or at grade line. Where snow buildup and water splashes against the face of the building a more dense, less adsorbent brick should be used. Under normal conditions water will not pass completely through a brick itself - unless the original backed-on facing has become defective due to spalling or splitting. Sandblasting will also damage a brick face and should be avoided. Another avenue for water infiltration in a masonry wall is through hairline cracks between the brick and mortar. Mortar used to repair or repoint the building previously may have contributed to the brick deterioration. The mortar should not be harder than the surfaces it is bonding, in this case, the brick. Type N (750 psi) is the preferred standard for exterior above grade use according to ASTM C270. A Type S (1,800 psi) mortar is acceptable for below or at grade level. A thorough cleaning of the masonry surface is necessary prior to any work in order to better match the colors and textures. However, it is difficult to match original mortar and brick exactly. On the face of the Jr. Club House building, the brick has deteriorated leaving the mortar exposed. This would not have happened if a softer mortar were used as previously noted. In general, bond strength is more important than compression. The ability of the mortar to flex, or resist cracking, along with good workability are what is needed to maintain watertightness of the wall. Hard mortars often provide a poorer bond between materials resulting in hairline cracks and water penetration. Hardness of the mortar may also be contributing to spalling of the

9 brick face. MISCELLANEOUS Water can penetrate the building through various openings such as gaps in the sealant and voids in the wood trim. Sealant observed suffers from adhesive (failure of bond between sealant and adjacent surfaces). This may be attributed to either poor preparation, which includes cleaning of the surfaces or noncompatible materials. Either way, gaps are created that allow wind-driven rain to penetrate the wall system and should be corrected. Proper application of sealant requires a bond breaker tape or backer rod to fill any voids. Copper sheet metal flashing is acceptable for the use intended. Life expectancy of 16 ounce copper flashing is approximately 50 years. With regular maintenance, it can last much longer. END OF SECTION Evaluations Page 3

10 RECOMMENDATIONS GENERAL The masonry damage observed on both the Club House and Jr. Club House is directly related to water infiltration. With proper repair and regular maintenance, the building should provide an additional 100 years of service. The following is an estimated serviceable life of various building materials and can be used as a guide in considering the need for scheduled periodic maintenance: Brick Mortar Paint on Steel Sealant 100+ years years 3-5 years 4-10 years If the results of the crack monitoring indicate active movement in the building, additional investigation into the soil conditions will be required. Our recommendations are based on the assumption that the cracks are not active at this time and are repairable. RECOMMENDATIONS Club House: $ Clean entire face of the building to allow for proper matching of brick and mortar. $ Remove all damaged and defective brick on entire building. A damaged brick is one that is cracked, spalled or chipped, thereby jeopardizing its waterproofing properties. Areas highlighted on the drawings are schematic only. $ Inspect the entire building and remove any loose or deteriorated mortar to a depth of 1" and repoint with mortar to match original. We recommend you remove previously repointed areas that either do not match in color or are not of the appropriate composition. $ Inspect all window and door perimeters for proper sealant application. Remove defective areas and replace with backer rod and sealant. Paint to match trim. $ Monitor crack on southwest corner to determine if active. If active, additional soil investigation will be required to stabilize structure. $ Prepare and paint wood trim. Jr. Club House: $ Clean entire face of the building to allow for proper matching of brick and mortar. $ Remove all damaged and defective brick on entire building. A damaged brick is one that is cracked, spalled or chipped, thereby jeopardizing its waterproofing properties. Areas highlighted on the drawings are schematic only. Recommendations Page 1

11 $ Inspect the entire building and remove any loose or deteriorated mortar to a depth of 1" and repoint with mortar to match original. We recommend you remove previously repointed areas that either do not match in color or are not of the appropriate composition. $ Inspect all window and door perimeters for proper sealant application. Remove defective areas and replace with backer rod and sealant. Paint to match trim. $ Install a canopy or enclosure around fire escape to prevent ice buildup. $ Replace missing wood trim on eave. Scrape, prime and paint all wood trim along cornice. $ Replace lintels above windows where defective. Include flashing and weeps. REASONS: Corrective work will ensure that the masonry exterior is watertight and in sound condition. Masonry has a long life expectancy when properly installed and detailed. By matching the original brick and mortar, the original character of the building will be maintained. This is important in that the buildings are located within the historic district of Southport. ESTIMATED COST OF CONSTRUCTION Some of the dollar figures used were calculated based on information obtained from the 2003 Building Construction Cost Data published by Robert Snow Means Company, Inc., Kingston, Massachusetts. Additional figures were obtained from similar active projects with inflation and geographical percentages included. The final dollar amount shown is for guidance only and is a ball park figure. An assumption is made that all repair work will be performed under one contract and not spaced out over a period of time. The amount does not include any soft costs such as Architectural / Engineering fees or contingencies. Cost estimate work sheets are included under Appendix D. Estimated Cost... $ 172, END OF SECTION Recommendations Page 2

STRUCTURAL ASSESSMENT OBSERVATION REPORT

STRUCTURAL ASSESSMENT OBSERVATION REPORT Consulting Engineers THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road (330) 659-6688 phone Richfield, Ohio 44286 (330) 659-6675 fax www.thorsonbaker.com STRUCTURAL ASSESSMENT OBSERVATION REPORT

More information

Structural Conditions Assessment of Current Lapeer District Schools Administration Building 250 Second Street, Lapeer, Michigan

Structural Conditions Assessment of Current Lapeer District Schools Administration Building 250 Second Street, Lapeer, Michigan November 2, 2015 Melissa A. Malcolm Library Director Lapeer District Library 201 Village West Dr S Lapeer, MI 48446 RE: Structural Conditions Assessment of Current Lapeer District Schools Administration

More information

HARLEY CLARKE MANSION Condition Assessment

HARLEY CLARKE MANSION Condition Assessment HARLEY CLARKE MANSION Condition Assessment 2603 Sheridan Road Evanston, Illinois 60201 Final Report August 24, 2016 WJE No. 2016.5003 Prepared for: Ms. Lisa DiChiera Landmarks Illinois 30 North Michigan

More information

Jefferson Middle School Masonry Restoration. Columbia, Missouri

Jefferson Middle School Masonry Restoration. Columbia, Missouri Columbia, MO 65201 573-449-2683 fax: 573-442=6213 www.pwarchitects.com ADDENDUM #1 DATE: October 29, 2013 TO BIDDING DOCUMENTS ENTITLED: Columbia Public Schools Columbia, Missouri PWA PROJECT NUMBER: 201136.20

More information

DGM Consultants, P.A. Structural Engineering and Masonry Consulting FIELD REPORT #01

DGM Consultants, P.A. Structural Engineering and Masonry Consulting FIELD REPORT #01 DGM Consultants, P.A. Structural Engineering and Masonry Consulting FIELD REPORT #01 Project Carnegie Library Date 5/15/2012 DGM Project # 2012014 Location th 9 and Vermont Contractor The Garland Company,

More information

SECTION BRICK MASONRY ASSEMBLIES

SECTION BRICK MASONRY ASSEMBLIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Face brick. 2. Mortar and grout. 3. Ties and anchors. 4. Miscellaneous masonry accessories. 1.2 SUBMITTALS A. Product Data: For each type

More information

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone.

DIVISION 04 MASONRY CAST STONE. A. Design Considerations. 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. DIVISION 04 MASONRY 04720 CAST STONE A. Design Considerations 1. Cast stone shall comply with ASTM C1364, Standard Specification for Cast Stone. 2. Care must be taken in the design of individual units

More information

2019 IAQA Annual Meeting

2019 IAQA Annual Meeting Daniel Stih, CMC. CIEC Healthy Living Spaces Stanley Yeskolski CIEC, CMC Investigative Inspection Services Inc. 2 Purpose The presentation will provide a over view of: Installation Details Problem Areas

More information

Arts Center- Building needs

Arts Center- Building needs Arts Center- Building needs Built in 1928 Last renovated in 1986 Priority 1- fascia repair Loose, rotting and missing fascia needs to be replaced to prevent water intrusion. There are seven different pieces

More information

Design Guidelines for

Design Guidelines for Chapter 4 Architectural Features Design Guidelines for Architectural Features This chapter presents the design policies and guidelines for the rehabilitation of an historic resource located in Georgetown,

More information

East Lyme Middle School EAST LYME MIDDLE SCHOOL

East Lyme Middle School EAST LYME MIDDLE SCHOOL Description: N EAST LYME MIDDLE SCHOOL The school consists of a multi story building with lower, main and upper level floors. The typical floor framing for the main and upper levels is wide flange steel

More information

STAFF BRIEF. Project Scope and Staff Summary Under Review:

STAFF BRIEF. Project Scope and Staff Summary Under Review: Community Planning and Development Denver Landmark Preservation 201 West Colfax, Dept. 205 Denver, CO 80202 p: 720.865.2709 f: 720.865.3050 www.denvergov.org/preservation STAFF BRIEF This document is the

More information

Façade Improvement Specifications: 221 S. Lafayette, Greenville, MI. General Section:

Façade Improvement Specifications: 221 S. Lafayette, Greenville, MI. General Section: Façade Improvement Specifications:, Greenville, MI SEE ARCHITECTUAL RENDERINGS ATTACHED TO PROVIDE ADDITIONAL DETAIL: General Section: $ General Building Permit: Permit for working on project. Contact

More information

Limited Exterior Masonry Assessment Roosevelt Elementary School

Limited Exterior Masonry Assessment Roosevelt Elementary School Limited Exterior Volume 2 of 2 November 29. 2007 Produced for: Medford Public Schools Medford, Oregon In Consultation with: 710 NE 21 st Avenue, Suite 200, Portland, Oregon 97232 P: 503.517.0283 F: 503.517.0285

More information

PG&E BUILDING AT 215 MARKET STREET

PG&E BUILDING AT 215 MARKET STREET San Francisco, CA ICRI Northern California Chapter 2017 Concrete Repair Awards Simpson Gumpertz & Heger Inc. OVERVIEW The historic 215 Market Street Annex is a seven-story office building in downtown San

More information

Evaluation, Restoration and Protection of Sandstone Façade on a Historic Building The Boston Building Denver, CO Presenter: Leo Whiteley

Evaluation, Restoration and Protection of Sandstone Façade on a Historic Building The Boston Building Denver, CO Presenter: Leo Whiteley Circa 1910 Evaluation, Restoration and Protection of Sandstone Façade on a Historic Building The Boston Building Denver, CO Presenter: Leo Whiteley Boston Loft Building History On Southeast corner of 17

More information

May 17, Mr. Fred Preuss Oak Park River Forest High School 201 North Scoville Avenue Oak Park, IL 60302

May 17, Mr. Fred Preuss Oak Park River Forest High School 201 North Scoville Avenue Oak Park, IL 60302 Larson Engineering, Inc. 118 S. Clinton Street, Suite 250 Chicago, IL 60661-5775 312.345.0540 Fax: 312.332.1484 www.larsonengr.com May 17, 2016 Mr. Fred Preuss Oak Park River Forest High School 201 North

More information

Primary Concerns and Defects

Primary Concerns and Defects Primary Concerns and Defects Primary Concerns and Defects: Home Inspector Observations: Where to Look. What to Look For. What Observed condition may mean. Primary Concerns The points to be inspected per

More information

Rockland Library Assessment Executive Summary

Rockland Library Assessment Executive Summary Rockland Library Assessment Executive Summary performed for City of Rockland, Maine 270 Pleasant Street Rockland, ME 04841 February 2, 2016 Civil & Structural Engineering 132 Brentwood Street Portland,

More information

SITE AND BUILDING INSPECTION CHECKLIST

SITE AND BUILDING INSPECTION CHECKLIST PARISH BUILDING Page 1 of 6 SITE AND GROUNDS DATE INIT COMMENTS DATE INIT COMMENTS Ramps & Provisions for Handicap Designated parking spaces for Handicap Has soil dropped or heaved Is there standing water

More information

Water Penetration Resistance - Design and Detailing

Water Penetration Resistance - Design and Detailing Technical Notes on Brick Construction 7 114 Commerce Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Water Penetration Resistance - Design and Detailing Abstract: Proper design, detailing

More information

PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES

PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES PROGRAM COMMENT FOR DEPARTMENT OF DEFENSE REHABILITATION TREATMENT MEASURES APPENDIX 1 SECTION 04100.01 REMOVAL OF MORTAR JOINTS AND REPOINTING PART 1 GENERAL 1.01 DESCRIPTION A. This specification provides

More information

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories

DIVISION 04 MASONRY. Section Title Number MASONRY Maintenance of Masonry Masonry Mortaring Masonry Accessories 04 00 00 MASONRY 04 01 00 Maintenance of Masonry 04 01 20 Maintenance of Masonry 04 05 13 Masonry Mortaring 04 05 23 Masonry Accessories 04 20 00 UNIT MASONRY 04 21 00 Clay Unit and Brick Veneer 04 22

More information

Deterioration of building envelope of wooden apartment buildings built before 1940 based on external survey Paul Klõšeiko, Tõnis Agasild, Targo Kalame

Deterioration of building envelope of wooden apartment buildings built before 1940 based on external survey Paul Klõšeiko, Tõnis Agasild, Targo Kalame Deterioration of building envelope of wooden apartment buildings built before 1940 based on external survey Paul Klõšeiko, Tõnis Agasild, Targo Kalamees Chair of Building Physics and Architecture, Tallinn

More information

SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING

SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING SECTION 04210 INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING PART I GENERAL 1.1 SUMMARY A. Provide installation of new or replacement of masonry units and/or repointing of masonry units

More information

Distances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale

Distances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale patio and deck 00 Building Two story Four-plex Entrance 0 0 00 Building Single Story Duplex 0 patio Contact Information: Owner: Housing Authority of Yamhill County, NE Dunn Place, McMinnville, OR 9. Contact:

More information

******** Condominiums Masonry Assessment

******** Condominiums Masonry Assessment ******** Condominiums Masonry Assessment On April 23rd, 2014, I examined the exterior masonry conditions and photographed both general and specific conditions on the building. I was directed by **********,

More information

CITY OF TYLER HISTORICAL PRESERVATION BOARD CERTIFICATE OF APPROPRIATENESS APPLICATION (Unified Development Code Article XI, Division B)

CITY OF TYLER HISTORICAL PRESERVATION BOARD CERTIFICATE OF APPROPRIATENESS APPLICATION (Unified Development Code Article XI, Division B) CITY OF TYLER HISTORICAL PRESERVATION BOARD CERTIFICATE OF APPROPRIATENESS APPLICATION (Unified Development Code Article XI, Division B) Owner(s) of Property: Address of Property: Telephone Number: Please

More information

Property Inspection Report

Property Inspection Report DAVID A. MEACHAM Professional Inspection & Construction Services Property Inspection Report Prepared for David Smith Property Address 1154 Gulf View Drive Tampa Bay, Florida Inspection Date Friday, October

More information

Façade Improvement Specifications: 200 S. Lafayette, Greenville, MI SEE ARCHITECTUAL RENDERINGS ATTACHED. General Section:

Façade Improvement Specifications: 200 S. Lafayette, Greenville, MI SEE ARCHITECTUAL RENDERINGS ATTACHED. General Section: Façade Improvement Specifications:, Greenville, MI SEE ARCHITECTUAL RENDERINGS ATTACHED $ General Building Permit: TO PROVIDE ADDITIONAL DETAIL: General Section: Permit for working on project. Contact

More information

HERITAGE PERMIT APPLICATION SUBMISSION GUIDELINES

HERITAGE PERMIT APPLICATION SUBMISSION GUIDELINES HERITAGE PERMIT APPLICATION SUBMISSION GUIDELINES WHAT IS A DESIGNATED HERITAGE PROPERTY? A designated heritage property is a property that has been identified as historically or architecturally significant

More information

Historic Preservation DESIGN GUIDELINES

Historic Preservation DESIGN GUIDELINES CITY OF GRANBURY Historic Preservation DESIGN GUIDELINES 9. BUILDING EXTERIOR MATERIALS MASONRY: BRICK, STONE, TERRA COTTA, CONCRETE, STUCCO, AND MORTAR Commentary: Masonry features of brick cornices and

More information

109 S. MARKET CURTIS ARCHITECTURE & DESIGN PC SITE MAP EXISTING PHOTOGRAPH PROPOSED RENDERING

109 S. MARKET CURTIS ARCHITECTURE & DESIGN PC SITE MAP EXISTING PHOTOGRAPH PROPOSED RENDERING HISTORIC PHOTOGRAPH EXISTING PERSPECTIVE PROPOSED PERSPECTIVE TUCKPOINT ENTIRE BUILDING FACADE WITH MORTAR MATCHING ORIGINAL, REMOVE ALL FASTENERS, BRACKETS & MISC. METAL. REPAIR STAINED GLASS ABOVE EACH

More information

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples. SECTION 04812 (042012) MECHANICALLY ATTACHED BRICK PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

RECREATIONAL EAGLE CENTER METAL ROOF ASSESSMENT AND SOLUTION

RECREATIONAL EAGLE CENTER METAL ROOF ASSESSMENT AND SOLUTION RECREATIONAL EAGLE CENTER METAL ROOF ASSESSMENT AND SOLUTION Recreational Eagle Center (00550) La Crosse, WI DSF Project No. 07H1E SEG Project No. 10975 Prepared for Division of State Facilities 101 E.

More information

PHILMONT WAREHOUSE BUILDING PRELIMINARY STRUCTURAL ASSESSMENT

PHILMONT WAREHOUSE BUILDING PRELIMINARY STRUCTURAL ASSESSMENT PHILMONT WAREHOUSE BUILDING PRELIMINARY STRUCTURAL ASSESSMENT Prepared for: GATTER ARCHITECTS 111 MAIN ST. PHILMONT, NY 12565 Prepared by: TACONIC ENGINEERING, DPC PO BOX 272 CHATHAM, NY 12037 TACONIC

More information

Technical Notes 28 - Anchored Brick Veneer, Wood Frame Construction Rev August 2002

Technical Notes 28 - Anchored Brick Veneer, Wood Frame Construction Rev August 2002 Technical Notes 28 - Anchored Brick Veneer, Wood Frame Construction Rev August 2002 Abstract: This Technical Notes deals with the prescriptive design of brick veneer with wood frame construction in buildings

More information

The contemporary masonry wall. Flashing. Ice dams - bad End dams - good

The contemporary masonry wall. Flashing. Ice dams - bad End dams - good The contemporary masonry wall Designed to drain Kept dry with air cavity Expected to leak Uses foam plastic insulation 3 courses = 8 inches (one block course) Through wall flashing Weeps @ 16 o.c. Flashing

More information

Brick Masonry. Best Practices Guide

Brick Masonry. Best Practices Guide Brick Masonry Best Practices Guide 1. Brick 2. Brick Blending 3. Wall Ties 4. Flashing 5. Steel Lintels 6. Weep Holes 7. General Recommendations Content The information and suggestions contained in this

More information

LIFETIME WATERPROOFING SEALANT FREQUENTLY ASKED QUESTIONS

LIFETIME WATERPROOFING SEALANT FREQUENTLY ASKED QUESTIONS Welcome to the world's finest water sealant product. This page is designed to answer the most frequently asked questions about Lifetime Water Sealant 1). How many coats should I apply? One coat. Apply

More information

STATE PREFERENTIAL PROPERTY TAX ASSESSMENT PROGRAM

STATE PREFERENTIAL PROPERTY TAX ASSESSMENT PROGRAM GEORGIA DEPARTMENT OF NATURAL RESOURCES (DNR) - HISTORIC PRESERVATION DIVISION (HPD) PART A PRELIMINARY CERTIFICATION Section I Property and Owner Information STATE PREFERENTIAL PROPERTY TAX ASSESSMENT

More information

Design Guidelines for Construction and Renovation in the Longmeadow Historic District

Design Guidelines for Construction and Renovation in the Longmeadow Historic District Design Guidelines for Construction and Renovation in the Longmeadow Historic District Revision 2008.1 The following list of Guidelines has been compiled to facilitate the homeowner's planning for projects

More information

INTERNATIONAL BUILDING CODE

INTERNATIONAL BUILDING CODE INTERNATIONAL BUILDING CODE MODEL BUILDING CONDITIONS ASSESSMENT The Reid and Hughes building is a four-story, four-bay, brick building, constructed in 1869 with a later addition known as the Williams

More information

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public

More information

DESIGN TIPS TECHNICAL BULLETIN #47 FLASHING, WEEP HOLES AND RELATED ANCHORAGE [1 of 8]

DESIGN TIPS TECHNICAL BULLETIN #47 FLASHING, WEEP HOLES AND RELATED ANCHORAGE [1 of 8] FLASHING, WEEP HOLES AND RELATED ANCHORAGE [1 of 8] Proper flashing and weep holes are essential elements in exterior masonry walls. Together, they provide a means to control moisture in a wall. If not

More information

Introduction. LLB wishes to thank the Trustees, Director and Building Committee of the Gleason Public Library for their assistance and guidance.

Introduction. LLB wishes to thank the Trustees, Director and Building Committee of the Gleason Public Library for their assistance and guidance. 1 E x e c u t i v e s u m m a r y Introduction Architect Lerner Ladds + Bartels and engineers Simpson Gumpertz & Heger were selected to provide services to investigate and determine the causes of deterioration

More information

Thin Architectural Splitface Block Veneer Specification Guide

Thin Architectural Splitface Block Veneer Specification Guide Thin Architectural Splitface Veneer System with AccuTab Technology R Thin Architectural Splitface Block Veneer Specification Guide Section 04711: Manufactured Concrete Veneer Use this specification guide

More information

Maintenance of Brick Masonry

Maintenance of Brick Masonry TECHNICAL NOTES on Brick Construction 12007 Sunrise Valley Drive, Suite 430, Reston, Virginia 20191 www.gobrick.com 703-620-0010 46 December 2017 Maintenance of Brick Masonry Abstract: Even though one

More information

October 26, 2017 Ref.: Newfoundland & Labrador English School District 95 Elizabeth Avenue St. John s, NL A1B 1R6

October 26, 2017 Ref.: Newfoundland & Labrador English School District 95 Elizabeth Avenue St. John s, NL A1B 1R6 October 26, 2017 Ref.: 351-1 Newfoundland & Labrador English School District 95 Elizabeth Avenue St. John s, NL A1B 1R6 Attention: Mr. Jim Sinnott Director of Facilities & Custodial Management Dear Sir:

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MORTAR AND MASONRY GROUT SECTION 04110 MORTAR AND MASONRY GROUT PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. In the absence of other information, the methods and recommendations of the National Concrete Masonry Association

More information

The Town will coordinate with the adjacent property Owner for access allowing work to the East side of the building.

The Town will coordinate with the adjacent property Owner for access allowing work to the East side of the building. ADDENDUM #1 EXTERIOR REPAIRS YOUTH SERVICES BUREAU 63 LINDEN STREET MANCHESTER, CT 06040 BID #15/16-68 S/P+A PROJECT NO. 15.207 DATE: March 15, 2016 The following changes to the Drawings and Project Specifications

More information

Commercial Flashing Details

Commercial Flashing Details This technical note illustrates many of the most common flashing details for commercial buildings. The purpose for flashing is to direct moisture to the exterior and in so doing, prevent moisture from

More information

Dominion Traditional Building Group Fox Groves Road Remington, VA 22734

Dominion Traditional Building Group Fox Groves Road Remington, VA 22734 Dominion Traditional Building Group 6625 Wilson Road, Marshall, VA 20115 Phone: 540 326 1882 info@traditionalbuilders.net July 13, 2016 Property: Presqu Isle Address: 8183 Fox Groves Road Remington, VA

More information

Weatherproofing Masonry For Northern Climates

Weatherproofing Masonry For Northern Climates The enduring strength, beauty and performance of a brick wall assembly is critically dependant on three components: design, workmanship and materials. If even one of these factors has not been diligently

More information

SECTION UNIT MASONRY SYSTEM

SECTION UNIT MASONRY SYSTEM SECTION 04320 UNIT MASONRY SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Concrete masonry and face brick units. B. Reinforcement, anchorage, and accessories. 1.03 SUBMITTALS A. Submit product data under

More information

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS SECTION 08620 COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Masonry movement joints

Masonry movement joints Masonry movement joints are one of the most misunderstood and underappreciated technical issues in the masonry industry. The lack of properly located, detailed, specified, and installed masonry movement

More information

FAÇADE IMPROVEMENT PROGRAM AND ARCHITECTURAL STANDARDS

FAÇADE IMPROVEMENT PROGRAM AND ARCHITECTURAL STANDARDS FAÇADE IMPROVEMENT PROGRAM AND ARCHITECTURAL STANDARDS Architecture and Building Conditions in the Bellevue-Rutherford Neighborhood The architecture of the Bellevue-Rutherford neighborhood varies in style

More information

The Reconstruction of the Tony Dapolito Recreation Center 1 Clarkson Street New York, NY March 20, 2018

The Reconstruction of the Tony Dapolito Recreation Center 1 Clarkson Street New York, NY March 20, 2018 The Reconstruction of the Tony Dapolito Recreation Center 1 Clarkson Street New York, NY 10014 March 20, 2018 Table of Contents: Site Location Historical Context Existing Conditions Scope of Work Roof

More information

NEW YORK CITY SCHOOL CONSTRUCTION AUTHORITY CIP SUMMARY

NEW YORK CITY SCHOOL CONSTRUCTION AUTHORITY CIP SUMMARY PROJECT: Exterior Masonry JOB NO: D012259 SCHOOL: PS 189 K (Brooklyn) EXHIBIT 5 DATE: 2/13/2009 BUILDING ID: K189 REV: CONSULTANT: Goshow Architects FINAL ESTIMATE CIP SUMMARY GENERAL CONDITIONS $ 105,076

More information

Pottstown Historic Districts Maintenance and Renovation Guidelines

Pottstown Historic Districts Maintenance and Renovation Guidelines Maintenance and Permits Historic Districts established to protect Pottstown s assets Pottstown Council has established two historic districts to protect the Borough s oldest and most historic buildings.

More information

GUIDELINES FOR THE RENOVATION, RESTORATION, & PRESERVATION OF LANDMARKED PROPERTIES IN THE CITY OF CRYSTAL LAKE

GUIDELINES FOR THE RENOVATION, RESTORATION, & PRESERVATION OF LANDMARKED PROPERTIES IN THE CITY OF CRYSTAL LAKE GUIDELINES FOR THE RENOVATION, RESTORATION, & PRESERVATION OF LANDMARKED PROPERTIES IN THE CITY OF CRYSTAL LAKE INTRODUCTION: This document is designed to give the owner of a landmarked property in the

More information

Groundwater Seepage. Causes of Basement Seepage and Leaks Hydrostatic Pressure

Groundwater Seepage. Causes of Basement Seepage and Leaks Hydrostatic Pressure Groundwater Seepage The following guide can be used by you and your crews when assessing seepage at a property. Bear in mind that this guide is not all-inclusive, and should be used in a supplementary

More information

EXECUTIVE SUMMARY INTRODUCTION Terms of Reference Building Description Documents Reviewed SUMMARY OF FIELD DATA 4

EXECUTIVE SUMMARY INTRODUCTION Terms of Reference Building Description Documents Reviewed SUMMARY OF FIELD DATA 4 Abbott Place Wood Framed Window Condition Assessment May 30, 2012 TABLE OF CONTENTS EXECUTIVE SUMMARY 1 1.0 INTRODUCTION 2 1.1 Terms of Reference 2 1.2 Building Description 3 1.3 Documents Reviewed 3 2.0

More information

Architectural Technology V 1 MASONRY

Architectural Technology V 1 MASONRY Architectural Technology V 1 MASONRY Architectural Technology V 2 Order of the Day: > Housekeeping: Return Work Sheet #8; > Review: Work Sheet #8: LightGage Framing > Masonry Wall Assemblies > In-Class

More information

Master Specifications for Microcotta November 2017

Master Specifications for Microcotta November 2017 SECTION 042130 - MICROCOTTA PART 1 - GENERAL 1.1 SUMMARY A. Provide Architectural Microcotta, cast architectural polymer resin units manufactured in accordance with the Contract Documents. 1.2 WORK INCLUDED

More information

RSH ENGINEERING, INC. END OF BUILDERS WARRANTY INSPECTION REPORT INSP#: K00001 DATE: 00/00/11 PAGE #: 1

RSH ENGINEERING, INC. END OF BUILDERS WARRANTY INSPECTION REPORT INSP#: K00001 DATE: 00/00/11 PAGE #: 1 PAGE : 1 1 2 3 4 LEFT SIDE OF HOUSE: SEE. 3 TO. 10 FOR DETAILS. LEF T SIDE OF HOUSE: GENERAL NOTE: SOFFIT VENTS ARE MISSING AND/OR IS INADEQUATE ADD SOFFIT VENTS. PROVIDE ADEQUATE OF SOFFIT VENTS TO MEET

More information

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK )

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK ) WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK ) 1.0 Comparative wall systems Wood stud walls * walls are normally 2x4, but may be 2x6. * studs are spaced 16. * studs carry vertical loads.

More information

November 30, University of Virginia Facilities Management Engineering & Design Division P.O. Box Charlottesville, VA

November 30, University of Virginia Facilities Management Engineering & Design Division P.O. Box Charlottesville, VA University of Virginia Facilities Management Engineering & Design Division P.O. Box 400726 Charlottesville, VA 22904-4726 Attention: Reference: William Blodgett, AIA Project Manager University of Virginia

More information

Maintenance of Brick Masonry

Maintenance of Brick Masonry TECHNICAL NOTES on Brick Construction 46 1850 Centennial Park Drive, Reston, Virginia 20191 www.gobrick.com 703-620-0010 Maintenance of Brick Masonry Abstract: Even though one of the major advantages of

More information

SECTION UNIT MASONRY

SECTION UNIT MASONRY SECTION 04200 UNIT MASONRY PART 1 GENERAL 1.01 SUMMARY A. Furnish labor, materials, and equipment and perform functions required in the installation and maintenance of the work covered by this Section.

More information

EXTERIOR INSULATION & FINISH SYSTEMS PRELIMINARY INFORMATION

EXTERIOR INSULATION & FINISH SYSTEMS PRELIMINARY INFORMATION EXTERIOR INSULATION & FINISH SYSTEMS PRELIMINARY INFORMATION Style of Structure: Two Story. Estimate age of Structure: The house is 5-10 years old. Foundation: Utility Basement. Finished into living space

More information

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 STUC-O-FLEX PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960 PART 1 - GENERAL 1.01 DESCRIPTION Provide all labor, materials and equipment necessary

More information

Nathan Clifford School Building Conditions Assessment Report

Nathan Clifford School Building Conditions Assessment Report Nathan Clifford School Building Conditions Assessment Report Submitted To: The City of Portland April 12, 2013 Prepared By: Winton Scott Architects Becker Structural Engineers, Inc. Conditions Assessment

More information

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood Please Note: This checklist should not be relied upon as a home inspection report, nor should it be considered a substitute for a home inspection. This list is representative, but NOT exhaustive. If you

More information

SPEC-DATA SHEET SPLIT FACE ARCHITECTURAL BLOCK A. PRODUCT NAME B. MANUFACTURER C. PRODUCT DESCRIPTION PERMACON GROUP INC.

SPEC-DATA SHEET SPLIT FACE ARCHITECTURAL BLOCK A. PRODUCT NAME B. MANUFACTURER C. PRODUCT DESCRIPTION PERMACON GROUP INC. A. PRODUCT NAME SPLIT FACE Architectural Block B. MANUFACTURER PERMACON GROUP INC. 8145 Bombardier Street Anjou (Quebec) H1J 1A5 Telephone: (514) 351-2120 Fax: (514) 352-9802 Canadian Sales Offices Montreal:

More information

Fixing Brick. Fort Wayne Performing Arts Center Louis Kahn

Fixing Brick. Fort Wayne Performing Arts Center Louis Kahn Fixing Brick Fort Wayne Performing Arts Center Louis Kahn Fort Wayne Performing Arts Center Ü Arches and efflourescense The performing arts center was built in the late 1960 s. Like many projects it had

More information

Considerations in the Repair and Replacement of Historic Windows

Considerations in the Repair and Replacement of Historic Windows Considerations in the Repair and Replacement of Historic Windows Carolyn L. Searls, PE, LEED AP BD+C Senior Principal Taryn N. Williams, SE Senior Staff II Simpson Gumpertz & Heger California Preservation

More information

DISTRESS PHENOMENA OFTEN MISTAKEN FOR FOUNDATION MOVEMENT

DISTRESS PHENOMENA OFTEN MISTAKEN FOR FOUNDATION MOVEMENT Issued for Website Publishing Foundation Performance Association Structural Committee Page 1 of 5 PHENOMENA OFTEN MISTAKEN FOR FOUNDATION MOVEMENT by The Structural Committee of The Foundation Performance

More information

EXTERIOR SIDING CONDITION SURVEY

EXTERIOR SIDING CONDITION SURVEY EXTERIOR SIDING CONDITION SURVEY FOR FARRWOOD 2 CONDOMINIUMS 49-176 FARRWOOD DRIVE HAVERHILL, MA APRIL 2016 c/o PROPERTY MANAGEMENT OF ANDOVER, INC. P.O. BOX 488 ANDOVER, MA 01810 213 WEST STREET, MILFORD,

More information

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION SECTION 072700 VAPOR PERMEABLE AIR BARRIER LIQUID MEMBRANE PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. The Work of this Section, as shown or specified, shall be in accordance with the requirements of the

More information

WeatherSmart Air Barrier Installation Guide

WeatherSmart Air Barrier Installation Guide WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material

More information

Property Inspection Checklist

Property Inspection Checklist Property Inspection Checklist Use a checklist like this to make sure that you are looking at all parts of the house. Check off those items that are in good condition and make notes about those that are

More information

PB YONGE STREET QUEEN STREET WEST RICHMOND STREET. 2 QUEEN STREET WEST Toronto Preservation Board FORMERLY 184 YONGE 2 QUEEN

PB YONGE STREET QUEEN STREET WEST RICHMOND STREET. 2 QUEEN STREET WEST Toronto Preservation Board FORMERLY 184 YONGE 2 QUEEN PB23.6.1 YONGE STREET FORMERLY 184 YONGE 2 QUEEN QUEEN STREET WEST RICHMOND STREET 2 Queen Street West - P. Jamieson & Co, 1897 (Source: Toronto Public Library) 2 Queen Street West - current condition.

More information

Residential Uses in the Historic Village Core

Residential Uses in the Historic Village Core BLACK DIAMOND DESIGN GUIDLINES for Residential Uses in the Historic Village Core Adopted June 18, 2009 Introduction and Purpose These guidelines are intended to guide infill development within the Historic

More information

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC. 320-226.5189 www.101developmentresources.com While every attempt has been made to insure the correctness of this handout, no guarantees are made to its accuracy

More information

North Hanover Township School District North Hanover Township, New Jersey

North Hanover Township School District North Hanover Township, New Jersey SECTION 084413 - GLAZED ALUMINUM CURTAIN WALLS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

Historic Preservation Commission

Historic Preservation Commission Historic Preservation Commission APPLICATION F CERTIFICATE OF APPROPRIATENESS PROPERTY ADDRESS: DATE: APPLICANT S NAME: APPLICANT S MAILING ADDRESS: CITY:. ZIP: TELEPHONE # HOME/CELL: WK: EMAIL: PROPERTY

More information

O UR L ADY OF THE A SSUMPTION C ATHOLIC C HURCH 35 O LD E AGLE S CHOOL R OAD S TRAFFORD, PA 19087

O UR L ADY OF THE A SSUMPTION C ATHOLIC C HURCH 35 O LD E AGLE S CHOOL R OAD S TRAFFORD, PA 19087 R EPORT E XTERIOR W ALL I NSPECTION O UR L ADY OF THE A SSUMPTION C ATHOLIC C HURCH 35 O LD E AGLE S CHOOL R OAD S TRAFFORD, PA 19087 S UBMITTED TO : O UR L ADY OF THE A SSUMPTION C HURCH C /O N ICOLE

More information

STRUCTURAL CONDITION ASSESSMENT

STRUCTURAL CONDITION ASSESSMENT STRUCTURAL CONDITION ASSESSMENT ALLEN JAY ROCK GYM 1201 FAIRFIELD ROAD HIGH POINT, NC Prepared for: Prepared by: Guilford County Schools 617 West Market Street Greensboro, NC Adrian S. Durham, PE, SE,

More information

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces Sto Corp. 3800 Camp Creek Parkway Building 1400, Suite 120 Atlanta, GA 30331 Tel: 404-346-3666 Toll Free: 1-800-221-2397 Fax: 404-346-3119 www.stocorp.com 80212R StoColor Lastic Acrylic-Based, Elastomeric

More information

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology FLASHING DETAILS FOR CONCRETE MASONRY WALLS TEK 19-5A Water Penetration Resistance

More information

REPORT OF ROOF CONDITION STUDY. YOUR FACILITY Your Facilities Location. Date YOUR FACILITY S IDENTIFICATION. Prepared for Your Company

REPORT OF ROOF CONDITION STUDY. YOUR FACILITY Your Facilities Location. Date YOUR FACILITY S IDENTIFICATION. Prepared for Your Company REPORT OF ROOF CONDITION STUDY YOUR FACILITY Your Facilities Location YOUR FACILITY S IDENTIFICATION Date Prepared for Your Company 1114 Grindstone, Union, Kentucky 41091 (859) 657-6677 [Report Date] [Client]

More information

KORA_Req._for_Eng._Studies_on_Stouffer_Apts. KU Reference No

KORA_Req._for_Eng._Studies_on_Stouffer_Apts. KU Reference No 000130 1 PURPOSE: Professional Engineering Consultants, P.A. (PEC) was engaged by University of Kansas Design & Construction Management to perform an assessment of Stouffer Place Apartment Building 20

More information

Anson County. Facilities Assessment & Proposed Improvements to BC Moore & Historic Courthouse

Anson County. Facilities Assessment & Proposed Improvements to BC Moore & Historic Courthouse Anson County Facilities Assessment & Proposed Improvements to BC Moore & Historic Courthouse Presentation to the Board of County Commissioners March 26, 2007 Participants & Credits Outline of Presentation

More information

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant Spec Component: SC-070-03/10 Sikaflex- 15LM Part 1 - General DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section 07900 Joint Sealers Elastomeric and non-elastomeric sealant 1.01 Summary A. This specification

More information

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3

BUILDING ENVELOPE DESIGN GUIDELINES APPENDIX 3 PART 1 GENERAL BUILDING ENVELOPE DESIGN GUIDELINES 1.01 INTRODUCTION A. This is a guideline on the Owner s minimum standards for: 1. Masonry Division 04 2. Copings Division 04 or 07 3. Cavity wall flashings

More information

ARTICLE 3 OVERLAY ZONES. Table of Contents

ARTICLE 3 OVERLAY ZONES. Table of Contents ARTICLE 3 OVERLAY ZONES Table of Contents 3.01.00. HISTORIC DISTRICTS AND LANDMARKS... 2 3.01.01. Definitions... 2 3.01.02. Local Register Of Historic Places... 2 3.01.03. Criteria for Listing on the Local

More information

City of Aurora, Ohio. Architectural Board of Review. Residential Guidelines

City of Aurora, Ohio. Architectural Board of Review. Residential Guidelines City of Aurora, Ohio Architectural Board of Review Residential Guidelines The Architectural Board of Review (ABR) is guided by a set of general goals outlined by the City of Aurora that address certain

More information

SECTION 6.3 DOWNTOWN HISTORIC DISTRICT (DTH)

SECTION 6.3 DOWNTOWN HISTORIC DISTRICT (DTH) SECTION 6.3 DOWNTOWN HISTORIC DISTRICT (DTH) A. Purpose Wylie's downtown has been identified by the Comprehensive Plan as a valuable resource worthy of preservation as a historic district. This district

More information