SERIES SURGICAL LIGHTS

Size: px
Start display at page:

Download "SERIES SURGICAL LIGHTS"

Transcription

1 SERIES SURGICAL LIGHTS TEC-B-0012 REV1 Skytron's Aurora LED Surgical Lighting provides advanced bright, cool and color correct illumination to the surgical field and a selectable color temperature of 4,000K (soft white) or 4,500K (bright white) based upon surgeon preference for every procedure. Focusable LEDs extend illumination range while retaining maximum intensity at any distance, with LED pod life retaining 80% of original intensity for an average of 10 years or 20,000 hours of use. Typical applications include General, Orthopedic, Plastics, Vascular, Cardiovascular, OB/GYN, Trauma, Neurosurgery and Urology.

2 AUR5 2267mm 89 1/4" 610mm TECHNICAL DATA 144 watts (490 BTU/hr) 1.6 amps 4,000K=135,000 Lux (12,542fc) 4,500K=120,000 Lux (11,148fc) 132 lbs./59.9 Kg ft. lbs./532.8 N m TEC-B REV0

3 AUR5TV 2267mm 89 1/4" 1" Diameter CAMERA READY Camera Connector 610mm 144 watts (490 BTU/hr) 1.6 amps 4,000K=135,000 Lux (12,542fc) 4,500K=120,000 Lux (11,148fc) lbs./62.4 Kg. 426 ft. lbs./577.3 N m TEC-B REV0

4 AUR7 2716mm 107" 1200mm 47 1/4" 1969mm 77 1/2" 425mm 16 3/4" 144 watts (490 BTU/hr) 1.6 amps 4,000K=160,000 Lux (14,870fc) 4,500K=139,000 Lux (12,918fc) 149 lbs./67.6 Kg ft. lbs./835 N m TEC-B REV0

5 AUR7TV 2716mm 107" 1200mm 47 1/4" 1" Diameter CAMERA READY 1969mm 77 1/2" Camera Connector 425mm 16 3/4" 144 watts (490 BTU/hr) 1.6 amps 4,000K=160,000 Lux (14,870fc) 4,500K=139,000 Lux (12,918fc) lbs./71 Kg ft. lbs./888.8 N m TEC-B REV0

6 AUR mm 97" 610mm 288 watts (980 BTU/hr) 3.2 amps 4,000K=270,000 Lux (25,084fc) 4,500K=240,000 Lux (22,296fc) lbs./97.6 Kg ft. lbs./1,094.3 N m 8'-9" min. 10'-5" max. TEC-B REV0

7 AUR55TV 2462mm 97" 1" Diameter CAMERA READY Camera Connector 610mm 288 watts (980 BTU/hr) 3.2 amps 4,000K=270,000 Lux (25,084fc) 4,500K=240,000 Lux (22,296fc) lbs./100.1 Kg ft. lbs./1,138.9 N m TEC-B REV0

8 AUR mm 107" 1200mm 47 1/4" 1969mm 77 1/2" 425mm 16 3/4" 610mm 288 watts (980 BTU/hr) 3.2 amps 4,000K=295,000 Lux (27,412fc) 4,500K=259,000 Lux (24,066fc) lbs./105 Kg ft. lbs./1,332.6 N m TEC-B REV0

9 AUR75TV 2716mm 107" 1200mm 47 1/4" 1" Diameter CAMERA READY 1969mm 77 1/2" Camera Connector 425mm 16 3/4" 610mm 288 watts (980 BTU/hr) 3.2 amps 4,000K=295,000 Lux (27,412fc) 4,500K=259,000 Lux (24,066fc) lbs./108.7 Kg. 1,016.2 ft. lbs./1,377 N m TEC-B REV0

10 AUR7TV5 2716mm 107" 1200mm 47 1/4" 1" Diameter CAMERA READY 1969mm 77 1/2" Camera Connector 425mm 16 3/4" 610mm TECHNICAL DATA 288 watts (980 BTU/hr) 3.2 amps 4,000K=295,000 Lux (27,412fc) 4,500K=259,000 Lux (24,066fc) lbs./108.7 Kg. 1,023.2 ft. lbs./1,386.5 N m 8'-9" min. 10'-5" max. TEC-B REV0

11 2657mm 105" 1335mm 52 1/2" AUR mm 432 watts (1,469 BTU/hr) 4.8 amps 4,000K=405,000 Lux (37,626fc) 4,500K=360,000 Lux (33,444fc) lbs./141.7 Kg. 1,269.5 ft. lbs./1,720.2 N m 9'-2" min. 10'-4" max. TEC-B REV0

12 2657mm 105" 1335mm 52 1/2" AUR555TV 1" Diameter CAMERA READY Camera Connector 610mm 432 watts (1,469 BTU/hr) 4.8 amps 4,000K=405,000 Lux (37,626fc) 4,500K=360,000 Lux (33,444fc) lbs./144 Kg. 1,269.5 ft. lbs./1,720.2 N m TEC-B REV0

13 2657mm 105" 1335mm 52 1/2" AUR mm 47 1/4" 1969mm 77 1/2" 610mm 425mm 16 3/4" 432 watts (1,469 BTU/hr) 4.8 amps 4,000K=430,000 Lux (39,954fc) 4,500K=379,000 Lux (35,214fc) lbs./149.4 Kg. 1,445.4 ft. lbs./1,958.5 N m 9'-2" min. 10'-4" max. TEC-B REV0

14 2657mm 105" 1335mm 52 1/2" AUR57TV5 1" Diameter 1200mm 47 1/4" CAMERA READY 1969mm 77 1/2" Camera Connector 610mm 425mm 16 3/4" 432 watts (1,469 BTU/hr) 4.8 amps 4,000K=430,000 Lux (39,954fc) 4,500K=379,000 Lux (35,214fc) lbs./151.9 Kg. 1,485.2 ft. lbs./2,012.4 N m 9'-2" min. 10'-4" max. TEC-B REV0

15 2657mm 105" 1335mm 52 1/2" AUR575TV 1" Diameter 1200mm 47 1/4" CAMERA READY 1969mm 77 1/2" Camera Connector 610mm 425mm 16 3/4" 432 watts (1,469 BTU/hr) 4.8 amps 4,000K=430,000 Lux (39,954fc) 4,500K=379,000 Lux (35,214fc) lbs./151.9 Kg. 1,445.4 ft. lbs./1,958.5 N m 9'-2" min. 10'-4" max. TEC-B REV0

16 AURORA II WALL CONTROL 120VAC 30VDC 3/4" CONDUIT CONDUIT CONNECTOR FINISHED WALL NOTE: FRONT EDGE OF "BACK-BOX" MUST BE FLUSH WITH FINISHED WALL SURFACE CONTROL BOX WITH RECESS MOUNT FLANGE INSTALLED RECESS DEPTH "BACK-BOX" DIMENSIONS SINGLE / DUAL 8-1/2"W x 11-5/8"H x 4"D TRIPLE 10-1/2"W x 14-1/2"H x 4"D (2) GROMMETS A B FRONT PANEL C ANCHOR (4) RECESS MOUNT FLANGE E D SCREW (4) JUNCTION BOX 20,000 HOUR INDICATOR MAIN POWER 2A, 250V Fast Acting 2A, 250V Fast Acting COLOR TEMPERATURE INDICATOR 4,500K WHEN ILLUMINATED RECESSED MOUNT FRONT PANEL RECESS MOUNT FLANGE OPTIONAL BACK-BOX INSTALLATION A B C D E F ANCHOR (4) SINGLE OR DUAL 8" 4" 10" 6-7/8" 7-5/8" 5-7/8" DIMENSIONS RECESS MOUNT FLANGE 11-3/4"W x 14"H TRIPLE 10" 4" 13-1/2" 8-5/8" 11" 6-3/8" 13-3/4"W x 17-1/4"H SCREW (4) ANCHOR (4) 20,000 HOUR INDICATOR MAIN POWER 2A, 250V Fast Acting 2A, 250V Fast Acting COLOR TEMPERATURE INDICATOR 4,500K WHEN ILLUMINATED F 1" 3" 3" C SCREW (4) SURFACE MOUNT SIDE VIEW A BACK VIEW TEC-B REV0

17 STANDARD MOUNTING STRUCTURE GUIDELINE TOP VIEW STIFFENER PLATE DETAIL 6" 12" 9-1/2" Hole for Access to Fixture Junction Box 6" STIFFENER PLATE (provided by others) 9-1/2" 12" 2" x 2" ANGLE SWAY BRACING 90 APART - 4 EACH (see note 2) Structural Ceiling (4) 2" x 2" Angle Sway Bracing (see note 2) Finished Ceiling 1-3/8" 12" x 12" x 3/8" Stiffener Plate 3/4" Metal Flex (see note 3) Fixture Junction Box 3/4" All Thread Rod (see note 1) 6" Max/ 4 Min. 2-1/4" ± 1/4" 15" dia. Mounting Plate (SKYTRON Supplied) 16-1/2" dia. Access Hole 18" dia. Ceiling Cover (SKYTRON Supplied) NOTES 3/4" support rods located for total support of light, all labor and materials for fabrication supplied by General Contractor. 3/4" nuts and washers for support of SKYTRON mounting plate supplied by contractor (8 ea. required). The mounting structure must be attached to structural ceiling and BRACED TO ALLOW NO TWISTING OR LATERAL MOTION and shall be designed not to provide a degree of rotation greater than two-tenths of a degree at the mounting plate. 3/4" metal conduit and minimum 12AWG wire size (3 wires per lighthead) required between fixture and SKYTRON supplied wall control. All metal conduit, wiring, and other electrical materials as well as installation labor for such materials associated with the installation of the SKYTRON surgical light to be provided by Electrical Contractor. All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON representative. All wiring to be in accordance with local codes and by a certified electrician. Optional Camera Ready Systems require a 1 diameter conduit from the fixture junction box to the camera control connector junction box. 65 camera control cable with faceplate and connector supplied by SKYTRON. and 2 x 4 junction box supplied by General or Electrical Contractor. CONTRACTOR HAS FINAL RESPONSIBILITY for the strength and stability of the Mounting Structure. This is a GENERAL GUIDELINE ONLY. TEC-B REV0

18 RECESSED MOUNTING STRUCTURE GUIDELINE TOP VIEW STIFFENER PLATE DETAIL 6" 12" 9-1/2" Hole for Access to Fixture Junction Box 6" STIFFENER PLATE (provided by others) 9-1/2" 12" 2" x 2" ANGLE SWAY BRACING 90 APART - 4 EACH (see note 2) Structural Ceiling Finished Ceiling (4) 2" x 2" Angle Sway Bracing (see note 2) 3/4" 12" x 12" x 3/8" Stiffener Plate 3/4" Metal Flex (see note 3) Fixture Junction Box 3/4" All Thread Rod (see note 1) 6" Max/ 4 Min. 1/4" NOTES 3/4" support rods located for total support of light, all labor and materials for fabrication supplied by General Contractor. 3/4" nuts and washers for support of SKYTRON mounting plate supplied by contractor (8 ea. required). The mounting structure must be attached to structural ceiling and BRACED TO ALLOW NO TWISTING OR LATERAL MOTION and shall be designed not to provide a degree of rotation greater than two-tenths of a degree at the mounting plate. 3/4" metal conduit and minimum 12AWG wire size (3 wires per lighthead) required between fixture and SKYTRON supplied wall control. All metal conduit, wiring, and other electrical materials as well as installation labor for such materials associated with the installation of the SKYTRON surgical light to be provided by Electrical Contractor. All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON representative. All wiring to be in accordance with local codes and by a certified electrician. Optional Camera Ready Systems require a 1 diameter conduit from the fixture junction box to the camera control connector junction box. 65 camera control cable with faceplate and connector supplied by SKYTRON. and 2 x 4 junction box supplied by General or Electrical Contractor. CONTRACTOR HAS FINAL RESPONSIBILITY for the strength and stability of the Mounting Structure. This is a GENERAL GUIDELINE ONLY. 15" dia. Mounting Plate (SKYTRON Supplied) 16-1/2" dia. Access Hole 20-1/8" dia. Ceiling Cover (SKYTRON Supplied) HEADROOM CLEARANCE INCREASE - 2" TEC-B REV0

19 Typical Mounting Structure Shown SEISMIC APPLICATION MOUNTING STRUCTURE GUIDELINE TOP VIEW STIFFENER PLATE DETAIL 6" SS-L Contact SKYTRON representative for Seismic Calculations if Applicable 12" 9-1/2" Hole for Access to Fixture Junction Box 6" STIFFENER PLATE (provided by others) 9-1/2" 12" ANGLE SWAY BRACING 90 APART - 4 EACH (see note 2) Structural Ceiling Finished Ceiling (4) Angle Sway Bracing (see note 2) 1-3/8" 12 x 12 x 3/8 Stiffener Plate 3/4" Metal Flex (see note 3) Fixture Junction Box Support Rods (see note 1) 18" dia. Mounting Plate (SKYTRON Supplied) 19" dia. Access Hole 20-1/8" dia. Ceiling Cover (SKYTRON Supplied) As Specified by Seismic calculations 2-1/4" ± 1/4" B UNIVERSAL ADAPTER PLATE B CASTLE TYPE CEILING COVER NOTES Support rods as specified per seismic calculations are to be located for total support of light, all labor and materials for fabrication supplied by General Contractor. Nuts and washers for support of SKYTRON mounting plate supplied by contractor (8 ea. required). The mounting structure must be attached to structural ceiling and BRACED TO ALLOW NO TWISTING OR LATERAL MOTION and shall be designed not to provide a degree of rotation greater than two-tenths of a degree at the mounting plate. 3/4" metal conduit and minimum 12AWG wire size (3 wires per lighthead) required between fixture and SKYTRON supplied wall control. All metal conduit, wiring, and other electrical materials as well as installation labor for such materials associated with the installation of the SKYTRON surgical light to be provided by Electrical Contractor. All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON representative. All wiring to be in accordance with local codes and by a certified electrician. Optional Camera Ready Systems require a 1 diameter conduit from the fixture junction box to the camera control connector junction box. 65 camera control cable with faceplate and connector supplied by SKYTRON. and 2 x 4 junction box supplied by General or Electrical Contractor. CONTRACTOR HAS FINAL RESPONSIBILITY for the strength and stability of the Mounting Structure. This is a GENERAL GUIDELINE ONLY. TEC-B REV0

20 49512

SERIES SURGICAL LIGHTS

SERIES SURGICAL LIGHTS SERIES SURGICAL LIGHTS TEC-B-0012 REV1 Skytron's Aurora LED Surgical Lighting provides advanced bright, cool and color correct illumination to the surgical field and a selectable color temperature of 4,000K

More information

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms REV. 9/08 Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms SKYTRON MOUNTING STRUCTURES for Ceiling Mounted Equipment Foreword Skytron s objective is to provide a program and guideline to assist

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS TEC-B-0136 REV0 04/15/15 AUA SERIES SURGICAL LIGHTS (STANDARD RADIAL ARM MODELS ONLY) Read this manual before starting to work! This information is necessary for the safe and

More information

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets Seismic Frame Two-Post Rack Page 11-3 Seismic Protection Products - Racks Page 11-6 Seismic Protection Products - Runway Page 11-8 Seismic

More information

Installation Manual. Retractable Ceiling Column Models 8301 & 8301PC

Installation Manual. Retractable Ceiling Column Models 8301 & 8301PC Retractable ceiling column Installation Manual Retractable Ceiling Column Models 8301 & 8301PC Overview The Retractable Ceiling Column is a convenient and cost-effective way of supplying medical gas and

More information

INSTALLATION INSTRUCTIONS SORIC INTEGRATION CENTER

INSTALLATION INSTRUCTIONS SORIC INTEGRATION CENTER INSTLLTION INSTRUCTIONS SORIC INTEGRTION CENTER TEC-F-0018 REV2 3/11 SITE CONDITIONS Shipping Weight SORIC-72 950lbs. SORIC-48 675lbs. Rough Opening Recessed applications require a 74 W x 79 H x 30 D rough-in

More information

Table of Contents... 1, 2. (EF) Equipment Floor... VISR EF 102 Water Heater VISR EF 104 Chiller VISR EF 105 End Suction Pump...

Table of Contents... 1, 2. (EF) Equipment Floor... VISR EF 102 Water Heater VISR EF 104 Chiller VISR EF 105 End Suction Pump... VISR Standard Details - TOC VISR-SD File No: T-VISR-SD-00 Supersedes: New Date: 6-Mar-204 Date: New VISR Standard Details: Table of Contents Table of Contents..., 2 (EF) Equipment Floor... VISR EF 0 Tank...

More information

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE TRUMPF MEDICAL SYSTEMS Inc. Charleston, SC PRE-INSTALLATION GUIDE FOR CEILING MOUNTED EQUIPMENT MANAGEMENT SYSTEMS, SURGICAL / EXAM LIGHTS, AND FLAT PANELS EMS and Light Pre-installation Guide File: 110720

More information

SEISMIC RESTRAINT SYSTEM

SEISMIC RESTRAINT SYSTEM 1. GENERAL 1.1. Description: SECTION 16012 SEISMIC RESTRAINT SYSTEM 1.1.1. This specification covers design and installation of seismic bracing and anchorage required for conduit, cable tray, bus duct,

More information

Suggested Materials and Tools:

Suggested Materials and Tools: NOISE CONTROL RESILIENT CEILING WAVE HANGER (Worldwide Patents Pending) INSTALLATION GUIDELINES Suggested Materials and Tools: Kinetics Noise Control CPT resilient tape for perimeter of room 0.875 tall

More information

2005 Seismic Bracing System. Kindorf Modular Metal Framing

2005 Seismic Bracing System. Kindorf Modular Metal Framing 2005 Seismic Bracing System Kindorf Modular Metal Framing What is Seismic Bracing? Seismic Bracing is support systems that account for forces generated by an earthquake Vertical Pipes or Duct hanging overhead

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

Durable, Dependable and Adaptable. Our complete line of patented support boxes and braces are quick and easy to install.

Durable, Dependable and Adaptable. Our complete line of patented support boxes and braces are quick and easy to install. Durable, Dependable and Adaptable Our complete line of patented support boxes and braces are quick and easy to install. Solid support, Quality materials, Great value. Contractors and homeowners trust sturdy

More information

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure Notice: If you are using MasterFormat 2004 Edition, the proper section number to use is Section 09 69 00, Access Flooring, which appears below. If you are continuing to use MasterFormat 1995 Edition, the

More information

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS Rev. 1.5 1.10.13 Toll free (800) 288-6000 or www.hubbell-wiring.com P a g e 0 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING- When using

More information

INSTALLATION MANUAL RECTANGULAR COLUMN

INSTALLATION MANUAL RECTANGULAR COLUMN INSTALLATION MANUAL RECTANGULAR COLUMN Model # 5502 OVERVIEW The Rectangular Column is a UL-listed, multi-sided, vertical hospital modular service assembly. This system uses vertical and/or horizontal

More information

Suggested Materials and Tools:

Suggested Materials and Tools: NOISE CONTROL RESILIENT CEILING WAVE HANGER (Worldwide Patents Pending) INSTALLATION GUIDELINES Suggested Materials and Tools: Kinetics Noise Control CPT resilient tape for perimeter of room 0.875 tall

More information

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES KNOXVILLE, TENNESSEE SECTION 26 05 29 PAGE 1 PART 1 - GENERAL: 1.01 DESCRIPTION OF WORK: SECTION 26 05 29 A. Extent of supports, anchors, sleeves and seals is indicated by drawings and schedules and/or

More information

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN FIXED CEILING COLUMN Installation Manual FIXED CEILING COLUMN INTRODUCTION Location, sequence of services and orientation of Surgical Ceiling Columns are specified on the building plans. Be certain installation

More information

SECTION SEISMIC CONTROL OSHPD

SECTION SEISMIC CONTROL OSHPD SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components

More information

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver. The Knife Edge Cove is a modular lighting system consisting of two parts: 1- An aluminum fixture housing extrusion 2- Drop-in lighting modules The fixture will provide a continuous knife edge architectural

More information

JASPER. PAGE 2: 2x2 T-GRID INSTALLATION. PAGE 3: 2x2 SRI SHEETROCK INSTALLATION. PAGE 4: 2x2 IEM INSTALLATION

JASPER. PAGE 2: 2x2 T-GRID INSTALLATION. PAGE 3: 2x2 SRI SHEETROCK INSTALLATION. PAGE 4: 2x2 IEM INSTALLATION 2016 JASPER CM2082 (2x2) PAGE 2: 2x2 T-GRID INSTALLATION PAGE 3: 2x2 SRI SHEETROCK INSTALLATION PAGE 4: 2x2 IEM INSTALLATION PAGE 5: INSTALLATION OF THE EARTHQUAKE CLIPS Drawing: 762300XX_2x2 Rev: A Sheet:

More information

Project No

Project No PART 1 - GENERAL 1.1 SECTION INCLUDES A. Seismic Requirements for single rod hanger supports for conduit, pipe and other similar systems. B. Seismic Requirements for trapeze type supports for cable tray,

More information

INFRALED 60 Remote and Wall Controlled Adjustable Recessed Lighting System

INFRALED 60 Remote and Wall Controlled Adjustable Recessed Lighting System 760429 INFRALED 3401 EAST JEFFERSON AVENUE DETROIT, MI 48207-4232 60 OWNER'S MANUAL & INSTALLATION GUIDE Remote and Wall Controlled Adjustable Recessed Lighting System CATALOG NUMBER: MRS-17600 OVERVIEW

More information

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector mm M0-.5 Turnbuckle connections to structural steel 30mm Perimeter Extrusion Simple supported 4 screw assembly and vertically supported flanged grid 750 Montevideo Road Tel (40)799-4200 Main Runner with

More information

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available. Concrete inserts offered in this section are designed to provide a pre-set support point in concrete ceilings, walls, and floors. A range of inserts with varying design loads are available. Materials Carbon

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

2005 Seismic Bracing System. Superstrut Metal Framing

2005 Seismic Bracing System. Superstrut Metal Framing 2005 Seismic Bracing System Superstrut Metal Framing What is Seismic Bracing? Seismic Bracing is support systems that account for forces generated by an earthquake Vertical Pipes or Duct hanging overhead

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility Bridge Pit 1504 1/2" 38214 244" 6198 1" 25 16 15 14 13 12 11 10 9 8 7 25 6 5 51 3/16" 1300 4 3 2 1 Impact 2270P 2455 5/16" 62365 1379 1/2" 35039 - Barrier nos. 5-13 Anchored Ground Line Note: (1) Test

More information

INFRALITE Infrared Remote Controlled Adjustable Recessed Lighting System

INFRALITE Infrared Remote Controlled Adjustable Recessed Lighting System 760422 OWNER'S MANUAL & INSTALLATION GUIDE Infrared Remote Controlled Adjustable Recessed Lighting System CATALOG NUMBERS: RR01202 (TWO Luminaire System) RR01203 (ONE Luminaire System) FEATURES and SPECIFICATIONS

More information

JAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION

JAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION JAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION PART 1 - GENERAL 1.1 APPLICABLE PUBLICATIONS: The publications listed below form a part of this specification

More information

UNDERFLOOR AIR DISTRIBUTION SYSTEM

UNDERFLOOR AIR DISTRIBUTION SYSTEM PART 1 - GENERAL 1.1 Section Includes A. Work of this section includes, but is not limited to the following: i. High performance concrete or composite core access floor system. ii. Perimeter fin tube enclosure,

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

METHOD STATEMENT FOR Dry Ceiling With Resilient Hanger

METHOD STATEMENT FOR Dry Ceiling With Resilient Hanger METHOD STATEMENT FOR Dry Ceiling With Resilient Hanger Revisions Details: Rev. Date of Issue Prepared 0 6/15/2011 AH Engineering Manager Reviewed QA/QC Manager Approved Project Director Description Originator:

More information

Area 1 see S2.0. New top of catwalk " Existing top of catwalk "±

Area 1 see S2.0. New top of catwalk  Existing top of catwalk ± General Notes: 1. Design Specifications: International Building Code (2015 Edition). Design Loads: Catwalks for maintenance access: 40PSF Dead load: Actural 2. The construction falsework/shoring/design

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

SLIM lamp CEILING version

SLIM lamp CEILING version Rev.5 Page 1 of 8 Slim TECHNICAL DATA 400 Performances at 1mt distance Slim Light intensity at 1m (Ec) 50klx Color temperature (K) 5000 Color rendering index (CRI) 94 Luminous source n 12Led x2w Focusing

More information

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. AFC Cable Systems, Inc. Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-MC

More information

Foundation Specifications

Foundation Specifications Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas ulletin 37835A Revision L Introduction This document specifies typical foundation characteristics, designs,

More information

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS SECTION 16711-27 05 28.33 PART 1 - GENERAL 1.01 SUMMARY A. This section includes Labor, materials and equipment necessary to complete the installation required for the items specified under this Section,

More information

Compression Superstructure TELETOM 500/700 Series Equipment Management Booms TELETOM 400/600 Series Anesthesia Booms

Compression Superstructure TELETOM 500/700 Series Equipment Management Booms TELETOM 400/600 Series Anesthesia Booms Contractor s Summary for Compression Superstructure TELETOM 500/700 Series Equipment Management Booms TELETOM 400/600 Series Anesthesia Booms Document # 70-000-00195 rev 01! WARNING This summary dimensional

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0528 Pathways. Page 1 of 6

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 27 Communication 0528 Pathways. Page 1 of 6 1 General 1.1 Scope of work 1.1.1 The Contractor is held responsible to be familiar with the provisions contained herein and with other Sections of this Specification as applicable to the completion of

More information

Flextray - Accessories

Flextray - Accessories Flextray - 40 Flextray - Protects cable from debris and dust Adds security to cable installation Easy bend-over tabs secure cover to trays Available for 2 (50mm) to 24 (600mm) wide trays Comes in 118 (2997mm)

More information

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF SIGN LUMINAIRES

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF SIGN LUMINAIRES ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 612 SEPTEMBER 1984 CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF SIGN LUMINAIRES 612.01 SCOPE 612.02 REFERENCES 612.03 Not Used 612.04 Not Used

More information

KINETICS Pipe & Duct Seismic Application Manual

KINETICS Pipe & Duct Seismic Application Manual QUICK START READ ME FIRST I1.1 Seismic Restraint Categories and Types: Seismic restraints for pipe and duct are generally separated into to two categories. 1. Transverse Seismic Restraints: These act to

More information

Kaf-Tech Product Specification

Kaf-Tech Product Specification Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519.13 METAL CLAD CABLE-LUMINARY CABLE

More information

Seismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE

Seismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE SRSCR-0 Seismic Restraints Cent-R-Rail Supplement* Multi-Directional Bracing For Data-Track, Half-Rack and Multi-Tier Half-Rack Systems Structural Engineer S 9 *To be used in conjunction with Cooper B-Line

More information

Seismic Installation Manual

Seismic Installation Manual Seismic Installation Manual This manual provides the design strength capacities and installation guidelines for the Restraint systems brace components for use in the design of an overall bracing/restraint

More information

FAST picker TP80 4 axis industrial robot - picker

FAST picker TP80 4 axis industrial robot - picker FAST picker TP80 4 axis industrial robot - picker A unique 4 axis and 6 axis robot range for all applications Whenever industrial companies need speed, Designed to work in the most hostile repeatability

More information

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100 42/621 VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) 10-23-2014 ILS-01100 MODEL NUMBERS: Unenclosed VPL-3300B Series : Models VPL-3353B and VPL-3375B (DC-powered) 3-Gate

More information

Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas

Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas Bulletin 37835A Revision E Introduction This document specifies typical foundation characteristics, designs,

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

CHR5-RES Residential Ceiling Hinge

CHR5-RES Residential Ceiling Hinge SHEET 1 of 6 IN OUT 90 DEGREES A motorised mechanism to reveal a display from the ceiling. This version hinges down by up to 100 degrees. The size reference for this version is CHR5-RES. The mechanism

More information

SEISMIC CONTROL MEASURES By Richard Lévesque, ing., P.Eng., LEED AP

SEISMIC CONTROL MEASURES By Richard Lévesque, ing., P.Eng., LEED AP SEISMIC CONTROL MEASURES By Richard Lévesque, ing., P.Eng., LEED AP Outline What and Why of Seismic Restraint Applicable Codes & Standards for Seismic Restraint Where and When of Seismic Restraint General

More information

The Kodiak 3200 Seating System by Royal Stewart Ltd.:

The Kodiak 3200 Seating System by Royal Stewart Ltd.: The Kodiak 3200 Seating System by Royal Stewart Ltd.: PART 1 GENERAL 1.01 Summary A. Bleacher System shall be Series 3200 Platforms as manufactured by Royal Stewart Ltd., Winnipeg, Manitoba, in accordance

More information

SECTION METAL STAIRS

SECTION METAL STAIRS SECTION 05 51 00 METAL STAIRS PART 1 GENERAL 1.1 SUMMARY A. Section includes steel stair frame of structural sections, with closed risers; pan to receive concrete fill stair treads and landings; integral

More information

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16 long / 1/2 thick or 16 oz. copper Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper Modular CABANA Kit 16 x 16 (6x6) Hipped Roof & Build-in Transoms Entry Key Lock Set (bright brass or dark bronze)

More information

Aurora Genmounts Install LT Installation Manual

Aurora Genmounts Install LT Installation Manual Aurora Genmounts Install LT Installation Manual TABLE OF CONTENTS 1.0 INTRODUCTION 2.0 PRODUCT OVERVIEW 3.0 TECHNICAL SPECS 4.0 INSTALLER RESPONSIBILITY 5.0 SITE SELECTION 6.0 TOOLS REQUIRED 7.0 COMPONENT

More information

SECTION ENCLOSED BUS ASSEMBLIES

SECTION ENCLOSED BUS ASSEMBLIES SECTION 262500 ENCLOSED BUS ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Also available in Premium Finishes See submittal SUB for Premium Finishes

Also available in Premium Finishes See submittal SUB for Premium Finishes PM1 DUAL J TREE STRAP CATALOG NUMBER: LAMP(S): NOTES: Example PM1DJ - TS-20-1 - BZP - SC Series PM1DJ Mounting TS - Length Fixture Position - Tree Strap (Specify Adjustable Strap Length) Minimum 3" Adjustable

More information

Install Instruction LOOP RECESSED

Install Instruction LOOP RECESSED LOOP RECESSED T F W 604.549.9379 604.549.9555 fluxwerx.com Install Instruction 1 X 1 6" X 1 6" X 1.5 ATTENTION: This installation guide does not apply to Loop Recessed 1x2, 2x2, 1x4, 2x4, 6"x2 and 6"x4.

More information

ELECTRICAL SECTION 2

ELECTRICAL SECTION 2 ELECTRICAL SECTION 2 COMMON WORK RESULTS FOR ELECTRICAL PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. This Section includes raceways, conductors and cables, grounding materials, boxes, electrical identification

More information

WC SERIES SPECIFICATION SECTION ACCESS FLOORING

WC SERIES SPECIFICATION SECTION ACCESS FLOORING PART 1 - GENERAL 1.1 Section Includes A. Work of this section includes, but is not limited to: access floor panels, factory applied floor finishes, understructure, grommets, cut outs and grounding connectors.

More information

Rough-in frame and flush-mount panel installation instructions

Rough-in frame and flush-mount panel installation instructions Welch Allyn, Inc. 3 State Street Road Skaneateles Falls, NY 33 USA Rough-in frame and flush-mount panel installation instructions 726080 DIR 8002869 Ver. A Revised 206- The Welch Allyn In-Floor Scale models

More information

INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS

INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS Publication No. US-NEBS-IM-003 September 2013 INSTRUCTIONS for ASSEMBLING NEBS FLOODED RACKS Read all instructions carefully and observe all warnings before

More information

SPECIAL SPECIFICATION 1924 Neighborhood Friendly High Mast Illumination System

SPECIAL SPECIFICATION 1924 Neighborhood Friendly High Mast Illumination System 1993 Specifications CSJ 2374-01-154 SPECIAL SPECIFICATION 1924 Neighborhood Friendly High Mast Illumination System 1. Description. This Item shall govern for furnishing and installing the various types

More information

Seismic Installation Manual

Seismic Installation Manual Seismic Installation Manual California Office of Statewide Health Planning & Development OPA-2123-10 This manual provides the design strength capacities and installation guidelines for the Bracing System

More information

CHRT6-RES Residential Ceiling Hinge With Telescope

CHRT6-RES Residential Ceiling Hinge With Telescope SHEET 1 of 6 IN OUT A motorised mechanism to reveal display from the ceiling. This version hinges down by 90 degrees and then telescopes the television further down from the ceiling. The size reference

More information

VERsacourt LED Light System Installation Instructions

VERsacourt LED Light System Installation Instructions VERsacourt LED Light System Installation Instructions PART LIST TEE BAR ASSEMBLY 10 12 LIGHT ASSEMBLY (hardware included) EXTENSION COLLAR BASE POLE EXTENSION POLE ANCHOR PAGE 1 REQUIRED TOOLS AND MATERIALS

More information

228 EXPRESS CASH RECYCLER 8, 10 OR 12 ROLLED STORAGE MODULES IN A UL SAFE (FRONT LOAD) PERSPECTIVE PLAN VIEW PAGE 1 OF 5

228 EXPRESS CASH RECYCLER 8, 10 OR 12 ROLLED STORAGE MODULES IN A UL SAFE (FRONT LOAD) PERSPECTIVE PLAN VIEW PAGE 1 OF 5 R 228 EXPRESS CASH RECYCLER 8, 0 OR 2 ROLLED STORAGE MODULES IN A UL SAFE (FRONT LOAD) L26 CALL -800--600 CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE

More information

1. Hangers and supports for electrical equipment and systems.

1. Hangers and supports for electrical equipment and systems. PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 DEFINITIONS... 1 1.4 PERFORMANCE REQUIREMENTS... 1 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 2 1.7 COORDINATION... 2 PART 2 - PRODUCTS...

More information

Fiberstars Lighted Laminar Flow Fountains

Fiberstars Lighted Laminar Flow Fountains Fiberstars Lighted Laminar Flow Fountains SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation and operation of Fiberstars Lighted Laminar Flow Fountain. The maximum lighted

More information

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip

Installation. Resilmount A237R. Installation Instructions. Furring channel sound isolation clip Resilmount A237R Furring channel sound isolation clip Installation Instructions Another Quality Building Product Installation A237R SPECIFICATIONS Width: 1-3/8 eight (including rubber): 1-1/16 Length:

More information

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt B3019 - Adjustable Metal Deck Ceiling Bolt Size Range: 3 /8"-16 thru 3 /4"-10 rod Function: For use in metal deck formed concrete to attach hanger rods. Allows for pre-positioning of hanger rods in poured

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

important SAFETY instructions READ carefully, SAVE these instructions, DELIVER to owner after installation

important SAFETY instructions READ carefully, SAVE these instructions, DELIVER to owner after installation 1. MINIMUM DISTANCE 2. 3. FROM WALL / CEILING from bracket center minimum 35.5 (90cm) 4. 5. 6. (1) Confirm fixture placement in the illumination plan, if applicable. If fixture placement from the wall

More information

Cantilevered Rail System

Cantilevered Rail System Knight Global's Cantilevered Rail Systems are designed to eliminate the need for a four post floor structure system. It provides an alternative to workstations with minimal floor space. A wide range of

More information

SPECIFICATION & DESIGN MANUAL " AISI 1060 to 1065 Rockwell Hardness 51 to 55 Perma-Seal coated Stick-E Pin 3/4" (Step Shank) 1"

SPECIFICATION & DESIGN MANUAL  AISI 1060 to 1065 Rockwell Hardness 51 to 55 Perma-Seal coated Stick-E Pin 3/4 (Step Shank) 1 Trak-It /Stick-E TM SPECIFICATION & DESIGN MANUAL TM Stick-E Electrical and Mechanical Fastening System PRODUCT DESCRIPTION The Stick-E fastening system uses Trak-It gas technology with specially designed

More information

VPL-3200B Residential Vertical Platform Lift Technical Specifications

VPL-3200B Residential Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:

More information

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1

MNL, SEL DIMENSIONS, SITE AW PLANNING GUIDE ARTWORK SIZE A SHEET 1 OF 1 Artwork and Signature File for: MAN-01120, MNL, SEL DIMENSIONS, SITE PLANNING GUIDE Artwork consists of: Thirty-Six (36) 8 ½ inch x 11 inch sheet(s) attached. REV AUTHORED BY DATE A.TAMBASCIO 01/20/10

More information

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project.

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project. SECTION 14654 WALL BRACKET JIB CRANE ***** Gorbel, Inc. manufacturers a broad range of material handling cranes including monorail, bridge, gantry, and jib cranes. Numerous work station and industrial

More information

Installation Instructions. Overview. Important Notes. LINCTM Enclosure EDB-WPM-GRX-6-CE

Installation Instructions. Overview. Important Notes. LINCTM Enclosure EDB-WPM-GRX-6-CE Installation Instructions Please Read Before Installing Overview The Enclosure is for use with Wallbox Power Modules (WPM) or 6-zone Grafik Eye Main Control Units. The Enclosure provides a means to prewire

More information

Welcome to Douglas County PUD

Welcome to Douglas County PUD Welcome to Douglas County PUD We are committed to providing the best possible utility services at the lowest possible cost consistent with sound business principles. To better serve you, please fill out

More information

Overview Steel City. Metallic Boxes and Covers. Advantages of Steel City. Boxes and Covers. Boxes & Covers Steel City Metallic Boxes

Overview Steel City. Metallic Boxes and Covers. Advantages of Steel City. Boxes and Covers. Boxes & Covers Steel City Metallic Boxes Steel City Metallic Boxes and Covers Steel City is the industry-leading product line of metallic switch and outlet boxes used in electrical construction. Since 1904, Steel City products have symbolized

More information

Item 442 Metal for Structures

Item 442 Metal for Structures Item 442 Metal for Structures 1. DESCRIPTION 2. MATERIALS Provide structural steel, high-strength bolts, forgings, steel castings, iron castings, wrought iron, steel pipe and tubing, aluminum castings

More information

RECESSED SolidCare STORAGE CABINETS

RECESSED SolidCare STORAGE CABINETS TEC-NP-0002 REV0 9/09 RECESSED SolidCare STORAGE CABINETS Weight lbs. kg. Empty 323 (146.51) Loaded 723 (327.92) Crated 438 (198.67) Interior Dimensions 44 7/8"W x 17"D x 55"H 18" 45 3/4" NPRS4818 Recessed

More information

hors Anc Eaton's B-Line series fasteners 183

hors Anc Eaton's B-Line series fasteners 183 183 Glossary Prefix - Description Screw Dia. Length Suffix ACB - Concrete Anchor Bolt 4 - #4 75-3 /4" AN - Acorn Nut ACPD - Bang-IT 6 - #6 81-13 /16" CH - Combo Head ACPW - Wood-Knocker 8 - #8 87-7 /8"

More information

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

VPL-3300B Commercial Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3300B Commercial Vertical Platform Lift Technical Specifications MODEL NUMBERS: Unenclosed VPL-3300B Series: Models VPL-3353B and VPL-3375B (DC-powered) 3-Gate VPL-3300B Series: Models

More information

DUPLEX INSTALLATION. Customer provides single service lateral attachment point in trough.

DUPLEX INSTALLATION. Customer provides single service lateral attachment point in trough. DUPLEX INSTALLATION A. GENERAL NOTES: The device shown may be used when the inspection authority having jurisdiction requires the installation of a service disconnecting means adjacent to the meter. MPC

More information

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems SEISMICALLY BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT DESIGN CRITERIA # 2 NON-STRUCTURAL ELEMENTS # 3 Restraint systems The next step in the non-specific design pathway in NZS

More information

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Plastic NEMA 4X, IP65 Enclosure

More information

Interior Hangers. Application

Interior Hangers. Application Application Interior bridge deck hangers are typically fabricated using two heavy duty sheet metal end clips that have been electrically resistance welded to an appropriate sized wire or formed metal connecting

More information

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions: Rev. 1 (Jun 30, 2016) Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions: Part # 4K01328-FI SC-CONVERSION Conversion Kit with MEI

More information

Large cable sizes stronger than pipe/strut

Large cable sizes stronger than pipe/strut Legrand Seismic Wire Rope/Cable Bracing is the recommended seismic bracing for Legrand wire mesh and ladder tray systems. It is UL Listed, complies with all building codes and standards, and offers significant

More information

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

B. Polyethylene samples shall be submitted for Owner approval of color and quality. Glass Rail ENGINEERED DASHERBOARD SPECIFICATIONS PART 1 - GENERAL 1.01 PROJECT SCOPE A. Contractor shall furnish and install one complete set of steel framed dasherboards as indicated on the drawings and

More information

RHE3 Dock Leveler Installation Manual

RHE3 Dock Leveler Installation Manual RHE3 Dock Leveler Installation Manual MADE IN U.S.A. This Manual Covers Dock Levelers Built After Serial Numbers: 07FE160001M and up PRINTED IN U.S.A. RITE-HITE PRINT SHOP PUBLICATION NO. 1222 MAY 2007

More information