Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
|
|
- Allyson Barnett
- 5 years ago
- Views:
Transcription
1 EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing Base Angle Fasteners to Concrete 24 O/C Base Z Flashing Base Trim with 1 1/2" Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Base Angle for Panels Which Overhang Slab Fasteners to Concrete 24 O/C Base Support Angle Optional in Lieu of Base Angle
2 EXTRUDED BASE DETAIL HORIZONTAL STACK JOINT DETAIL Set Panels in Butyl Sealant Base Extrusion Installed with 1 Wafer Heads 24 O/Cwith Base Angle Panel Clip with (2) ¼ 14 x 2 Rough Fasteners (As required for wind loads) Stack Flashing Stack Trim with (Shape may vary) Fasteners to Concrete 24 O/C Set Panels in Field Drill 3/8 Weep Holes 24 O/C Continuous 2 x 2 x 16 Ga. Angle (Minimum)
3 WALL PANEL TO HIGH EAVE TRANSITION Sealant Marriage Bead to Vertical Panel Joint Panel Clip with (2) ¼ - 14 Fasteners at Each Panel Joint WALL TO ROOF TRANSITION DETAIL Sealant Marriage Bead to Vertical Panel Joint Panel Clip with (2) ¼ - 14 Fasteners at Each Panel Joint Base Trim with Transition Flashing Stitch Teks at Each High Rib Outside Closure Set in 1/8 Butyl Tape Base Trim with Transition Flashing Stitch Teks 1/8 Butyl Tape 1/4-14 Through Fasteners (As required for wind load) Matching Flat Stock Material in Matching Color to be Field Bent and Broke For Closure of this Area Locate Expansion Fasteners at Purlin Ends Rake Angle with Up-turned Leg for Panel Attachment
4 EAVE DETAIL WITH GUTTER SYSTEM EAVE DETAIL WITHOUT GUTTER SYSTEM Inside Closure Strip with 1/8 Butyl Tape Between Roof Panel and Eave Trim Gutter Hanger Stitch Teks Inside Closure Strip with 1/8 Butyl Tape Between Roof Panel and Eave Trim Stitch Teks at 6 O/C Continuous 1/8 Butyl Tape Gutter Trim Eave Closure Trim ¼ - 14 Through Fasteners (As required for wind loads) NOTES: 1. Trim fasteners are typically 12 O/C. 2. Trims to be the same guage and color as panel facings. Low Eave Trim ¼ - 14 Through Fasteners (As required for wind loads)
5 HIGH EAVE DETAIL WITH GUTTER SYSTEM HIGH EAVE DETAIL WITHOUT GUTTER SYSTEM Outside Closure Set in 1/8 Butyl Tape High Eave Trim Stitch Teks at Each High Rib Stitch Teks at Each High Rib Outside Closure Set in 1/8 Butyl Tape High Eave Trim Butyl Sealant ¼ - 14 Through Fasteners (As required for wind loads) Butyl Sealant ¼ - 14 Through Fasteners (As required for wind loads)
6 OUTSIDE CORNER DETAIL (45 DEGREE MITER) Outside Corner with Field Miter Cut Panels for Corner Installation Will Vary with Field Condition Field Cut Clip Angles at End of Girts Will Vary with Field Condition NOTE: To run wall panels from corner in both directions for wall panels, cut male edges of both panels as shown. Inside Corner Trim with ¾ Phillips Pan Head Fastener Expansion Fasteners at Each Horizontal Support
7 OUTSIDE CORNER DETAIL (45 DEGREE MITER) Will Vary with Field Condition Field Cut Field-Cut Male Edges Where Applicable Outside Corner with Clip Angles at End of Girts Will Vary with Field Condition NOTE: To run wall panels from corner in both directions vertical for wall panels, cut male edges of both panels as shown. Inside Corner Trim with ¾ Phillips Pan Head Fastener Through-Fasten Panel at Corners with 1/4-14 Fasteners
8 EXRUDED CORNER TRIM DETAIL Standard Vertical Panel Joint with Panel Clips at Required Spacings Corner Snap-on Painted to Match Panel Color OUTSIDE CORNER DETAIL Aluminum 2 Piece Extrusion Installed with (2) 1 wafer heads at Each Horizontal Support Aluminum 2 Piece Extrusion Installed with (2) 1 wafer heads at Each Horizontal Support INSIDE CORNER DETAIL Aluminum 2 Piece Corner (Attach with 1 wafer head fasteners 24 O/C) Corner Snap-on Painted to Match Panel Color
9 EXTRUDED HEAD & SILL DETAIL Set Panels in Extrusion Installed with 1 Wafer Heads at Each Horizontal Support SILL CONDITION Door or Window Frame Field Drill 3/8 Weep Holes 24 O/C Silicone Sealant DETAIL AT HEAD Extrusion Installed with 1 Wafer Heads at Each Horizontal Support Set Panels in
10 EXTRUDED JAMB DETAIL Set Panels in EXTRUDED SOFFIT DETAIL Set Panels in Corners Snapon Painted to match Panel Color Extrusion Installed with 1 Wafer Heads at Each Horizontal Support Soffit Extrusion Installed with 1 Wafer Heads 24 O/C Support for Soffit Termination Required Door or Window Frame DETAIL AT JAMB Field Drill 3/8 Weep Holes 24 O/C Silicone Sealant
11 OPTIONAL EXTRUDED TRIMS CORNER EXTRUSION ASSEMBLY JAMB EXTRUSION ASSEMBLY BASE, HEAD, AND SILL EXTRUSION SOFFIT, HEAD, AND SILL EXTRUSION NOTE: Extruded trim options may not be available for all panel options. EcoSteel will help you select the best trim options for your panel selections. EcoSteel Building Systems 3100 Pinebrook Road Park City, Utah CEILING TEE EXTRUSION ASSEMBLY STACK JOINT EXTRUSION Phone:
KS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PP-01-KSV PANEL PROFILES CS-PP-02-KSV PANEL PROFILES CS-PP-03-KSV PANEL PROFILES CS-PJ-01-KSV KS SERIES EXPANDED PANEL JOINT CS-PJ-02-KSV KS SERIES ENGAGED PANEL JOINT CS-PJ-03-KSV
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More information200 / 300 SERIES PANELS COLD STORAGE
CS-DS-01-200/300 DISCLAIMER CS-CD-01-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CS-CD-02-200/300 KINGSPAN CEILING DESIGN POLICY AND PROCEDURES CONTINUED CI-PP-01-200 PANEL PROFILES 200 SERIES
More information900 SERIES PANEL SHEET INDEX ENDLAP INSTALLATION SEQUENCE L.E. W/ GUTTER VAPOR BARRIER CS-RK-01B-900
CS-PJ-01-900 CS-DS-01-900 CS-PJ-02-900 CS-EL-01-900 CS-EL-02-900 CS-EL-03-900 CS-EL-04-900 CS-RD-01-900 CS-RD-02-900 CS-RD-03-900 CS-EV-01A-900 CS-EV-01B-900 CS-EV-02A-900 CS-EV-02B-900 CS-EV-03A-900 CS-EV-03B-900
More informationProper Installation of Insulated Metal Wall Panels
Proper Installation of Insulated Metal Wall Panels Insulated metal panels (IMPs) are an ideal cladding solution for pre-engineered metal buildings. They are available in lengths up to 50, and may also
More information12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS
CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL
More informationCOMMERCIAL & INDUSTRIAL CI-CFR-INDEX SHEET INDEX CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER
CI-CFR-INDEX SHEET INDEX CI-CFR-INFO C & I DISCLAIMER CI-CFR-LG LEGEND CI-CFR-JT-01 PANEL JOINT CI-CFR-JT-02 PANEL JOINT SEQUENCE CI-CFR-JT-03 PANEL JOINT LAYOUT CI-CFR-SQ-01 PANEL INSTALLATION SEQUENCE
More informationFACE CFP - HORIZONTAL PANELS - OPTION 'B'
- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF
More informationHOME SYSTEMS CONSTRUCTION PROCEDURE
HOME SYSTEMS WWW.QUICKBUILTHOMES.COM.AU CONSTRUCTION PROCEDURE INDEX - PARTS LIST PARTS LIST QBRC75(C) QBRM75C) QBSIPS75 QBRFSZ75C QBRFBC75C QBRF3030G QBRGSQC QBRFRC75C QBRFZEC QBRF4040C QBSACC75 QBFR7330WC
More informationCOMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INDEX INSTALLATION SEQUENCE INSTALLATION SEQUENCE INSTALLATION SEQUENCE
COMPOSITE PANEL SYSTEM SYSTEM OVERVIEW INSTALLATION SEQUENCE TT 5-8 TT- 13 INSTALLATION SEQUENCE INSTALLATION SEQUENCE TT- 4 TT-10 TT-14 TT-12 TT- 3 TT-11 TT-10 TT- 9 TT-11 TT- 2 INDEX (TT- 0): SYSTEM
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationThin Brick Façade. Façades Installation Guide
Thin Brick Façade Façades Installation Guide October 2016 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels. Insulated panels serve as energy efficient,
More informationELEVATION FOR DETAIL REFERENCE ONLY
#smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR
More informationKARRIER PANEL - BRICK
KPH-DS-01-BRICK KPH-PJ-01-BRICK KPH-PJ-02-BRICK KPH-PJ-03-BRICK KPH-BS-01-BRICK KPH-BS-02-BRICK KPH-BS-03-BRICK KPH-OC-01-BRICK KPH-FO-01-BRICK KPH-FO-02-BRICK KPH-FO-03-BRICK KPH-FO-04-BRICK KPH-FO-05-BRICK
More informationPrestige Series 12. Installation guide
Prestige Series 12 Installation guide PIONEERING INSULATED METAL PANEL TECHNOLOGY CONTENTS Section Page Notes to Designer/User.................... 2 Panel Options............................. 3 Panel Details..............................
More informationMR2 SERVICES Site Reconstruction 54 College Street Des Moines, IA
Existing Yard Security Light Proposed Rooftop Mechanical Screening (Slate Gray) Proposed 3 x4 x 4 x4 Windows Metal Awning Existing Doors Metal Siding(Slate Gray) Trim (Matte Black) 14 14 Proposed Addition
More informationTYPICAL ROOF CONDITION LAYOUT
FIXED POINTS TYPICAL ROOF CONDITION LAYOUT 15 17 9 16 29 12 14 11 3 7 35 20 6 23 30 31 24 13 18 Typical Roof Condition Layout... 1 Low Eave Isometric View - Fixed/ Floating... 2 Low Eave Section - Fixed/
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationChapter 32 - Garage. June 2015 Garages 32-1
Chapter 32 - Garage Contents Chapter 32 - Garage... 32-1 Foundation... 32-3 Walls... 32-3 Roof Framing... 32-4 Roofing... 32-4 Exterior Dow Board... 32-5 Doors... 32-5 Siding... 32-5 Gutters... 32-6 Painting...
More informationELEVATION FOR DETAIL REFERENCE ONLY
8 4 5 6 9 16 10 15 11 SOFFIT 19 OUTSIDE CORNER 20 21 INSIDE CORNER 3 22 23 12 13 OPENING 14 END WALL 17 18 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY CSV-01 CSV-02 CSV-03 CSV-04 CSV-05 CSV-06 CSV-07 CSV-08
More informationBENCHMARK Evolution Axis
Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL
More informationIce Rink Renovation & New Clubhouse
SECTION 074243- METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationStudent Services & Classroom Addition
SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationNUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS
NUCOR VR 16 II STANDING SEAM ROOF SYSTEM TABLE OF CONTENTS Nucor VR16 II Vertical Rib Standing Seam Roof System...2 Nucor VR16 II Property and Span Tables...3 Standard Details...5 ED3010PE - Gutter...5
More informationWall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"
Thermafiber "RainBarrier 45" Nvelope "NH2" Bracket Adapter Nvelope Wall Bracket (90mm or as Req'd) ACM Metal Panel System Metal Panel Extrusion per ACM Manufactuer 1 2 " Self-Drilling Stainless Steel Fastener
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. COMMERCIAL RESIDENTIAL AGRICULTURAL MS-216 MS-218 Panel Guide This guide describes the design and performance characteristics of the MS-216 and MS-218 Roof panel system. The
More information* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.
is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.
More informationInstallation Instruction 3-D Model 3D 08/04/17. 0 Trespa Pura Siding System N/A WPS, Inc Wall Panel Systems Inc.
E H B G F I C K M J A D L Installation Instruction 3-D Model 3D 08/04/17 Detail: System Type: Scale: Drawn By: Wall Panel System, Inc. 0 Trespa Pura Siding System N/A WPS, Inc. Structural Substrate 15/16"
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationChapter 53: Endwall Overhang(s) Only - Enclosed
Chapter 53: Endwall Overhang(s) Only - Enclosed Most Common Mistakes: 1. Incorrect eave height. 2. Placing standard heel end trusses at same height as interior trusses. 3. Fascia board top edges not bevel
More informationFlushglaze For Steel Tube Applications and Horizontal Panels. Façades Installation Guide
Flushglaze 7500 For Steel Tube pplications and Horizontal Panels Façades Installation Guide September 2016 BENCHMRK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal
More informationDesignwall 2000/4000. Façades Installation Guide
Designwall 2000/4000 Façades Installation Guide July 2017 BENCHMARK Welcome to Kingspan, global leaders in the design and manufacture of insulated metal panels and building envelope solutions. Insulated
More informationNortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1
16 May 2014 Page 1 PART 1 GENERAL 1.1 DESCRIPTION This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More information7520 Casement Windows
Full casement Single casement Double-bottom casement Double casement FULL DOUBLE CASEMENT - Min 1 9 1 6 Max 3 0 5 0 or 2 6 6 0 CASEMENT W/ PICTURE - Min 4 6 1 6 Max 12 0 6 0 with 30 vent set - Minimum
More informationTABLE OF CONTENTS PRODUCT CATALOGUE fax OVERVIEW PBR 7.2 LONGSPAN ECONORIB
PRODUCT CATALOGUE www.metroll.us sales@fontana.metroll.com ph. 909.823.7663 fax 909.693.5153 TABLE OF CONTENTS OVERVIEW PBR Product Overview and Color Charts Panel Information and Trim 7.2 LONGSPAN ECONORIB
More informationENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 RAINSCREEN (RS) SYSTEM The Ultimate In Performance In A Dry-Joint System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationrockspan installation guide horizontally laid panel
rockspan installation guide horizontally laid panel A 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing face is consistent
More informationWHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.
WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. Build walls and ceilings with a strong base, sturdy reinforcements and much more with Phillips extensive line of high quality products. As a single source
More informationENVELOPE The Ultimate In Performance In A Wet-Sealed System ROUT & RETURN (RR) SYSTEM TECHNICAL MANUAL
ENVELOPE 2000 ROUT & RETURN (RR) SYSTEM The Ultimate In Performance In A Wet-Sealed System TECHNICAL MANUAL System Assembly Substrate Layouts CAD Sections/Details Physical Properties Performance Properties
More informationSWING DOOR SPECIFICATION
SWING DOOR A1 Work included: Furnish all necessary materials, labour and equipment for the complete installation of aluminum entrance doors, door frames and hardware as detailed on the drawings and specified
More informationChapter 25: Sliding Door Opening Framing
Chapter 25: Sliding Door Opening Framing Most Common Mistakes: 1. Locating header at incorrect height. 2. Failure to install siding backing. 3. Track board not installed, at wrong height, or cut to incorrect
More informationSUPERIOR ROOF SYSTEMS
SUPERIOR ROOF SYSTEMS S U P E R I O R M E T A L P R O D U C T S C O M P A N Y, I N C. Installation instructions & parts list DESCRIPTION CATALOG # 1. Tek Screw #14 x 4 7725 2. Dow 999-A Silicone 7679 3.
More informationSliding Patio Doors Premium Atlantic Aluminum
TABLE OF CONTENTS Specifications... 5-2 QuickSpecGuide... 5-3 Elevations: Scale 2-PanelDoors... 5-4 3-PanelDoors... 5-5 4-PanelDoors... 5-6 Grille Patterns... 5-7 SectionDetails: 3 &6 Scale... 5-8 WallDetails...
More informationDETAIL INSTRUCTION No. 1
BEFORE BEGINNING INSTALLATION, PLEASE READ THROUGH ALL INSTRUCTIONS. Uncrate shipment and check against packing list to insure all materials are included before beginning installation. If any discrepencies
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More informationPROLOK EAVE PROLOK ROOFING PANEL ROOFING NAIL
EAVE ROOFING NOTE: ROOF PITCH IS REQUIRED FOR FABRICATION LOW SLOPE ADD SEALER TAPE ROOFING NAIL 2x4 SUB- 2x8 EAVE TRIM 1. Install the eave trim using roofing nails. 2. If sealer tape is being used, install
More informationPRODUCT DESCRIPTION ACCESSORIES. Canopies
An overhanging or projecting roof structure off the sidewall or endwall with the extreme end usually unsupported. Mainly used for aesthetic application or to cover entrance or walkway. Options: Face Panel
More informationNATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System
0 00/NGC NATIONAL GYPSUM COMPANY -Hour Wall System The -Hour is a -hour fire wall consisting of in. (0. mm) light-gauge steel H-Studs that secure two layers of in. (. mm) shaftliner panels friction-fit
More informationRS24-10 Single-Section Skylight System
INSTALLATION INSTRUCTIONS RS24-10 VERSION 1.100316 DATED: 10/03/16 RS24-10 Single-Section Skylight System under/over seam clip double diverter US Patent D750,282 www.rnssales.com sales@rnssales.com 805.375.3980
More informationELEVATION FOR DETAIL REFERENCE ONLY
5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX
More informationCONTOUR CORRUGATED PANEL
CONTOUR CORRUGATED PANEL Table of Contents SECTION PAGE Designer Notes............................................... 1 Panel Net Coverage / Fasteners.................................... 2 ROOF Details
More informationCR# August 20, 2015
SECTION 07 40 00 - METAL ROOF AND WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Factory-formed and field-assembled, standing-seam metal roof panels. 2. Factory-formed and field-assembled,
More informationADP-2 LINER PANEL ERECTION GUIDE
ADP-2 LINER PANEL ERECTION GUIDE NOTE: See back side of cover for latest changes to this manual. BEHLEN MFG. CO. COLUMBUS, NE 68601 TECHNICAL INFORMATION 55063 Rev. 10/2/17 11/05/04 NOTE: If pink sheets
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationSECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 074213 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationSECTION NON-STRUCTURAL METAL FRAMING
SECTION 09 22 16 PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies steel studs wall systems, shaft wall systems, ceiling or soffit suspended or furred framing, wall furring, fasteners, and accessories
More informationTRIAD CORRUGATED METAL, INC.
TRIAD CORRUGATED METAL, INC. C O M M E R C I A L R E S I D E N T I A L A G R I C U L T U R A L Snap Loc Panel Guide Snap Loc metal panels are a perfect fit for residential, architectural and commercial
More informationSUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)
1 5 32 " 2" 27 32 " REQUIRED FOR 1 1 4 " 113 32 " 2 21 32 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL B1.2 12
More informationSenergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board
Senergy Platinum CI Stucco Typical details for an impact resistant cement plaster stucco system featuring Neopor GPS Plus Rigid Insulation Board NOTES Senergy Platinum CI Stucco Typical details for an
More informationPRE-ENGINEERED METAL BUILDING SYSTEM
PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,
More informationGAF EnergyGuard Polyiso Wall Sheathing
From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:
More information4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)
REQUIRED FOR DETAIL 7 1 8 " 7 8 " SUSPENSION REQUIREMENTS SEE DETAIL B1.2 8" 7 1 1 8 " 4 " 2 1 8 " SEE DETAIL B1.2 CARRIER SPAN VARIES DEPENDING ON DESIGN WIND PRESSURE 12 GA HANGER WIRE, BY OTHERS, NOT
More informationARCHED METAL FRAMED SKYLIGHTS EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING
EXARC Skylights, Inc (800) 247-5934 3793-B North Peachtree Road (770) 451-4352 Chamblee, GA 30341 fax(770) 451-4934 EXARC ARCHED GLAZING SYSTEM WITH ACRYLIC & POLYCARBONATE GLAZING PART 1 GENERAL 1.1 RELATED
More informationrainspan installation guide horizontally laid panel
rainspan installation guide horizontally laid panel standard details A C 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing
More informationADP-1 LINER PANEL ERECTION GUIDE
ADP-1 LINER PANEL ERECTION GUIDE NOTE: See back side of cover for latest changes to this manual. BEHLEN MFG. CO. COLUMBUS, NE 68601 TECHNICAL INFORMATION 55062 Rev. 8/23/12 NOTE: If pink sheets are included
More informationMatch The Product To The Purpose.
Copper Stockton Products' New Moisture Management Products Provide Solutions Stockton Products offers several profiles for water management and protection. One and two-piece products offer design features
More information6110 Horizontal Sliding Windows
6110 Horizontal Sliding Windows Half-vent Half-vent below Half-vent above Single-vent HALF-VENT - Min 2 0 1 0 Max 6 0 5 0 HALF-VENT ABVE - Min 2 0 2 0 Max 6 0 6 0 HALF-VENT BELW - Min 2 0 2 0 Max 6 0 6
More informationAL13. Intro. Vol 2 AL13. architectural panel system. Version 1. patent pending
01 AL13 Intro AL13 architectural panel system Vol 2 Version 1 www.al13.com patent pending CLAD THE WORLDTM 01 System Overview AL13 has changed the game. Our metal panel system is cut to fit and snaps together
More informationSeries Silicone structural glazed. Installation Instructions
Series 5600 Silicone structural glazed Installation Instructions Part NO. Y306 May 2016 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines 3-4 II. Perimeter Applications. 5 III. Anchor Installation.
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationELEVATION FOR DETAIL REFERENCE ONLY
4 5 6 8 18 13 10 15 SOFFIT OUTSIDE CORNER INSIDE CORNER 16 17 3 19 20 11 9 OPENING 12 END WALL 14 7 4 5 6 ELEVATION FOR DETAIL REFERENCE ONLY EH-01 INDEX EH-02 STANDARD PANEL OFFERING EH-03 SIDE LAP DETAILS
More informationWEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS
WEB BASED APPLICATION SPECIFIC INSTALLATION INSTRUCTIONS Window Fastening Although all possible measures have been taken to insure the accuracy of the material presented, WIXSYS, and the author are not
More informationAND ACCESSORIES FOR DRYWALL CONSTRUCTION
STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR
More informationDRY SEAL INSTALLATION GUIDE
DRY SEAL INSTALLATION GUIDE Effective September 2015 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationMilgard Double Bypass Horizontal Sliding Windows SERIES QUIET LINE VINYL JANUARY Min Max
Double bypass Double bypass above DUBLE DUBLE DUBLE DUBLE BYPASS - Min 2 0 1 0 Max 7 0 5 6 BYPASS ABVE - Min 2 0 2 6 Max 6 0 8 0 BYPASS BELW - Min 2 0 2 6 Max 6 0 8 0 BYPASS WITH FIED CENTER SASH - Min
More informationGuardian Wall Panel Installation Manual
Guardian 275 4 Wall Panel Installation Manual Guardian 275 4 Wall Panel Installation Manual This instructional manual provides General Installation Instruction. Installers should refer to the "as-built"
More informationUltra Wall System. CAD Detail Sets
Ultra Wall System CAD Detail Sets Contents Page UWS-CM CAVITYMATE Ultra Contents 1-0 FOR: Details continuing on 1-1 thru 1-17 Cavity cut XPS board to fit between ladder tie masonry ties in CMU walls UWS-SL
More informationWATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES
WINDOW REPLACEMENT GUIDELINES GENERAL 1. Complete and receive approval for WCA s Unit Modification Application for window replacement. 2. Obtain a permit for replacement window installation from the City
More informationrout & return INSTALLATION GUIDE
rout & return INSTALLATION GUIDE Effective October 2016 Tech Support: 800.523.2347 LaminatorsInc.com TABLE OF CONTENTS Handling and Maintenance of Omega-Lite Panels 1 System Limitations and Pre-Installation
More informationYCW 250 I-Beam Curtain Wall System Installation Manual
Installation Manual 2004 YKK AP America Inc. is a subsidiary of YKK Corporation of America. TABLE OF CONTENTS INSTALLATION NOTES..................................... Page ii PARTS DESCRIPTION Framing
More informationDistances are not shown to scale. Existing porch. Community. Building. Distances are not shown to scale
patio and deck 00 Building Two story Four-plex Entrance 0 0 00 Building Single Story Duplex 0 patio Contact Information: Owner: Housing Authority of Yamhill County, NE Dunn Place, McMinnville, OR 9. Contact:
More informationcomponents your source. exceptional service
components your source. exceptional service VP Components, established in 1998, serves customers across North America by providing building components and accessories designed to meet the needs of the
More informationPella 250 Series. Wood Frame Construction with Vinyl Siding... V250-ID-888 Wood Frame Construction with Brick Veneer...
SECTION DIRECTORY General Information Introduction... V250-ID-886 Installation Accessories and Applications... V250-ID-886 Typical Sealant Placement Details... V250-ID-887 Fin Installation Details Wood
More informationKBS-100 SNAP-LOCK PANEL & 5V PANEL I N S T A L L A T I O N M A N U A L
KBS-100 SNAP-LOCK PANEL & 5V PANEL I N S T A L L A T I O N M A N U A L KBS Metal Roofing KBS Metal Roofing General Information General Information Before beginning installation of panels, the installer
More informationSECTION STAINLESS STEEL WALL PANELS
SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.
More informationMetafor Panel System Installation Guide
Installation Guide innovative cladding design solutions Product Description Universal Flashing Kit Supplemental Guide for VM Pro-Zinc Training To enroll in a VM PRO-ZINC Training Course contact: UMICORE
More informationPre-Fabricated Roof Curbs
Knock Down Curb Assembly Instructions These roof curb assembly instructions are to be used as general guidelines only. Included with shipment are as-built drawings for proper location of sections and channels.
More information1 1/2" SSR. FABRAL The pursuit of excellence since 1967
1 1/2" SSR Detail Manual and Estimate Guide 16" 1 1 2" PROPER STORAGE When moisture remains in contact with Galvanized panels in the absence of freely circulating air, white, black or dark gray corrosion
More informationINSTALLATION MANUAL KOCH
INSTALLATION MANUAL KOCH TECHNICAL SYSTEMS GROUP PRE-FAB ACOUSTICAL/THERMAL PANELS AND ENCLOSURES GEORGE KOCH SONS, LLC TECHNICAL SYSTEMS GROUP 10 South Eleventh Avenue Evansville, Indiana 47744 812-465-9600
More informationSURESILL WATER MANAGEMENT GUIDE
THE SURE LEVEL OF PROTECTION SURESILL WATER MANAGEMENT GUIDE FOR WINDOWS AND DOORS *1 SLOPED SILL PAN ASSEMBLY Cut the channel plate ¼ smaller than the rough opening. Check the fit with end caps before
More information