EDIT ITEMS NOT INCLUDED IN THIS PROJECT
|
|
- Godwin Bradford
- 5 years ago
- Views:
Transcription
1 PART 1: GENERAL Premium Dry Erase Materials EDIT ITEMS NOT INCLUDED IN THIS PROJECT 1.01 SUMMARY A. Division Includes: 1. Dry Erase Wall Covering 2. Magnetic Self Stick Dry Erase Wall Coverings 3. Self Stick Dry Erase Wall Covering 4. Tackable Cork Dry Erase Wall Covering 5. Tray, Trim, and Presentation Rails 6. Accessories B. Related Divisions 1. Section 16500: Lighting: Permanent during Installation 2. Section 09250: Gypsum Board: Wall substrate. 3. Section 09950: Painting: Preparation and Priming of Substrate Surfaces. 4. Section 09950: Fabric Backed Wall Covering 5. Section 10100: Marker Boards and Chalkboards 1.02 REFERENCES A. American Society for Testing and Materials (ASTM) 1. ASTM E 84-91a Surface burning characteristics of building materials. B. Gypsum Association 1. GA-14-M-97 Recommended finish levels of gypsum board. C. NFPA 1.03 SUBMITTALS A. Manufacturers descriptive product data and installation instructions for all dry erase wall covering, adhesive, and accessory required. B. Manufactures recommended care and maintenance for all Jot-a-wall products. C. Samples: 1. 7 x9 sample of each dry erase material specified sample of all trim, tray, and end caps specified QUALITY ASSURANCE A. Installer: Installation by skilled commercial wall covering contractor with no less than three years of documented experience installing dry erase wall covering. B. SURFACE BURNING CHARACTERISTICS CLASSIFICATION: Provide materials that meet Class I/A rating when tested in accordance with ASTM E84 for flame spread and smoke developed C. Field Samples: Prepare field samples for architect s review and establish requirements for seaming and finish trim. 1. Install sample panel of each type presentation wall covering specified in area designated by architect. 2. Maintain corrected and approved samples to serve as a standard of performance for the project.
2 1.05 PRODUCT DELIVERY, STORAGE, AND HANDLING A. Deliver presentation wall coverings to the project site in unbroken and undamaged original factory packaging and clearly labeled with the manufacturer s identification label, quality or grade, and lot number. B. Store materials in a clean, dry storage area with temperature maintained above 50 F (10 C) with normal humidity. Store material within original packaging to prevent damage PRODUCT CONDITIONS A. Do not apply presentation wall coverings when surface and ambient temperatures are outside the temperature ranges required by the wall covering manufacturer. B. Provide continuous ventilation and heating facilities to maintain substrate surface and ambient temperatures above 55 F (13 C) unless required otherwise by manufacturer s instructions. C. Apply adhesive when substrate surface temperature and ambient temperature is above 55 F (13 C) and relative humidity is below forty percent. D. Maintain constant recommended temperature and humidity for at least 72 hours prior to and throughout the installation period, and for 72 hours after wall covering installation completion WARRANTY A. 5 year limited warranty. Jot-a-wall warrants that the surface will maintain its writing performance and not stain under normal conditions, when used in strict accordance with our care and maintenance instructions MAINTENANCE A. Before initial use of the writing surface, the material must be cleaned with Expo cleaner and a soft cloth. Then rinse with clean water and towel dry. We recommend the use of original Expo markers (sometimes called Expo Bold markers) for optimum performance. Other markers can also be used, but should be tested for acceptability before use across the entire writing surface. B. Long-term exposure of the Jot-a-wall dry erase surface to permanent markers may result in the marker penetrating the surface, leaving a permanent stain. Permanent marker may be removed by writing over the mark with a dry erase pen (using circular motions over the permanent marker) letting it dry and then erasing. Alternatively, the mark may be removed with isopropyl alcohol, but time is a critical factor in preventing migration of the marker into the material. The longer the permanent marker is left on the material, the more difficult it is to remove. C. Use only felt erasers. Remove dry-erase markings with a felt eraser for longer lasting surface effectiveness. Press firmly when erasing, using a circular motion. Change erasers as they become dirty. Dirty erasers leave excess ink on the surface of the board. D. Caution: Any sharp edged eraser can scratch the dry erase surface. Change erasers as they become soiled to avoid leaving excess marker residue on the surface of the board. For cleaning marker residue build-up, use Jot-a-wall s cleaner or Expo s dry erase cleaning solution and a soft towel. Then rinse with clean water and towel dry. For long term care we strongly suggest the entire writing surface be cleaned on a regular basis to insure the ultimate performance and appearance of the product. Warning: Never use abrasive cleaners or
3 PART 2: cleaning tools, hard edged erasers, sharp pointed writing instruments or sharp edged magnets on any Jot-a-wall products. PRODUCTS 2.01 DISTRIBUTOR A. Distributed by Contact sales representative at 2.02 MATERIALS SELECT ONE OR MORE OF THE FOLLOWING PRODUCTS A. JO-SS-50: Self-stick adhesive vinyl dry erase wall covering. Purpose is for resurfacing chalkboards or ghosted dry erase marker boards. 1. Total Weight: 24 oz. per lineal yard 3. Roll Width: 50 / 127 cm 5. Total Thickness: 11 mil/.279 mm B. JO-RM-SS: Vinyl dry erase wall covering with an adhesive backing. May be installed over finished primed drywall, old chalkboards, or ghosted dry erase boards. 1. Total Weight: oz. per lineal yard 3. Roll Width: 50 / 127 cm 5. Total Thickness: 8.3 mil/.2108 mm 6. Fire Rating: Class 1: NFPA C. JOM-SS-50: Vinyl dry erase wall covering with a magnetic surface and adhesive backing. Purpose is to convert a regular chalkboard or a ghosted dry erase board into a magnetic dry erase surface. 1. Total Weight: 30 oz. per lineal yard 3. Roll Width: 49 /50 / cm/127 cm 4. Roll Length: 50 / m 5. Total Thickness: 14 mil/.356 mm D. JOM-WC-50 and JOM-WC-60: Vinyl dry erase wall covering with a non-woven backing and a magnetic surface. Applied with commercial wall covering adhesive directly to a properly prepared drywall surface. 1. Total Weight: 35 oz. per lineal yard 2. Backing: Non-woven 3. Roll Width: 49 /50 / cm/127 cm 4. Roll Length: 50 / cm 5. Total Thickness: 21 mil/.533 cm E. JO-WC-50: Vinyl dry erase wall covering with a non-woven backing. Applied with commercial wall covering adhesive directly to a properly prepared drywall surface. 1. Total Weight: 25 oz. per lineal yard 2. Backing: Non-Woven 3. Roll Width: 49 /50 / cm/127 cm
4 5. Total Thickness: 19 mil/.483 mm F. JO-WC-60: Vinyl dry erase wall covering with a heavy woven backing. Is designed to either be installed as a single board or applied floor to ceiling to create an entire wall of dry erase surface. 1. Total Weight: 42.5 oz. per lineal yard 2. Backing: Woven 3. Roll Width: 58 /60 / cm/152.4 cm 4. Roll Length: 90 / m 5. Total Thickness: 14 mil 2.03 TRIM AND TRAY A. Aluminum Rail: Cork insert, Available in 1 and 2. B. Aluminum Marker Tray: 2-1/2 height and 2-3/4 tray base C. Aluminum Trim: 1-3/4 face and 5/16 depth 2.04 ACCESSORIES A. Adhesive: Heavy duty clear or clay based vinyl adhesive. B. Primer: White pigmented acrylic primer formulated for use with vinyl wall covering. PART 3: EXECUTION 3.01 EXAMINATION A. Observe before hanging, wall conditions to ensure wall conditions meet or exceed Level 4 finish. B. Test walls to receive dry erase material with moisture meter. Moisture shall not exceed 4 percent. C. Wall Surfaces shall be smooth, clean, structurally sound and free from imperfections that could show through the surface of the material. D. Contact the General Contractor and Architect in writing of any conditions that could cause delay to installation INSTALLATION SELECT ONE OR MORE OF THE PRODUCTS THAT APPLY A. WALLCOVERING BACKED MATERIAL: JOM-WC-50, JOM-WC-60, JO-WC-50, JO-WC Acclimate wall covering 24 hours before installation in the area to receive wall covering. 2. Follow manufacture s installation instruction. 3. Examine material for color, quality, and quantity, as specified prior to 4. Adhesive: Use heavy duty premixed clear or clay based vinyl adhesive. 5. Primer: Use a white acrylic wall covering primer. 6. Install all material in the exact order as it is cut from the bolt. Reverse hang alternate sheets. 7. Do not crease or bend material during installation. 8. Install horizontally using a level, or straight line. 9. When installing floor to ceiling, seam the material out of the optimum writing area. 10. Smooth the surface of the material with a wall covering smoother, wrapped with a soft cloth. Take out all air bubbles, wrinkles, gaps, and
5 overlaps. Do not use sharp edged smoothing tools. Smooth wall covering from the middle of the sheet to outside edges. 11. Removed any adhesive from the surface of the material using warm soap solution and rinse with clean water. 12. Make sure there isn t any residue of adhesive or soap left on the writing surface. 13. Stop installation of material that is questionable in appearance and call distributor of product. B. SELF STICK ADHESIVE: JO-SS-50 AND JO-RM-SS 1. Acclimate wall covering 24 hours before installation in the areas to received wall covering. 2. Examine material for color, quantity, and quality, as specified prior to 3. Follow manufacture s installation instruction. 4. Hang each sheet in the sequence as cut from the bolt. 5. Do not crease or bend the wall covering when handling the material. 6. Some Jot-a-wall product are installed with a soapy solution and some aren t. The products that use a soapy solution use 1/2 to 1 capful of mild dish water soap to 1 gallon of clean water. Using a pump sprayer cover the surface to be covered. 7. Slowly remove release linger and smooth material to surface using a wall covering smoother covered with a soft cloth. Use downward and outward motion to acclimate air bubbles. 8. Stop installation of material that is questionable in appearance and call your distributor. C. MAGNETIC SELF-STICK JOM-SS Acclimate wall covering 24 hours before installation in the areas to received wall covering. 2. Examine material for color, quantity, and quality, as specified prior to 3. Follow manufacture s installation instruction. 4. Hang each sheet in the sequence as cut from the bolt. 5. Do not crease or bend the wall covering when handling the material. 6. Do NOT wet when applying JOM-SS Slowly remove release linger and smooth material to surface using a wall covering smoother covered with a soft cloth. Use downward and outward motion to acclimate air bubbles. 8. Stop installation of material that is questionable in appearance and call your distributor CLEAN UP A. After installation remove all excess adhesive immediately using a soft cloth and warm soapy solution. B. Whether the product is installed with adhesive or is a self-stick product rinse the material with clean water after installation and dry with clean soft towel. C. After installation, remove rubbish and debris caused from the dry erase installation. Leave the area neat and clean. END OF SECTION
SECTION PRESENTATION DRY ERASE WALLCOVERING
SECTION 09720 PRESENTATION DRY ERASE WALLCOVERING Part 1 General 1.01 Summary EDIT ITEMS NOT INCLUDED IN THE PROJECT A. Section Includes: 1. Dry Erase Wallcovering 2. Low Glare Projection Dry Erase Wallcovering
More informationStop and Read Before Installing Material
Premium Dry Erase Materials Installation procedures for full wall application with woven and nonwoven backed products Stop and Read Before Installing Material Installation Procedures EXAMINATION Jot.a.wall
More informationSECTION POLYPROPYLENE FABRIC WALL COVERING
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 09 72 31 POLYPROPYLENE FABRIC WALL COVERING SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete any other item or paragraph not
More informationSECTION DRY ERASE COATING (IdeaPaint CREATE Black and White) A. Section Gypsum Board Assemblies; gypsum board substrate.
Guide Specifications for Designers and Specifiers: This document specifies IdeaPaint CREATE Dry Erase Coating by IdeaPaint, and is provided for your use in CSI 3-Part Format. For further assistance, call
More informationSECTION VINYL-COATED FABRIC WALL COVERINGS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 09 72 16 VINYL-COATED FABRIC WALL COVERINGS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationInstallation Instructions
Installation Instructions Installing Real Wood Veneers Wood Veneer Wallcovering Please read these instructions prior to installation. If you have any questions regarding the installation procedures contained
More informationGer-Eck, LLC SCRIBIL Dry Erase Clear Coat Section July 12, 2013 SECTION SCRIBIL Dry Erase Clear Coat
SECTION 09 96 66 SCRIBIL Dry Erase Clear Coat PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General Conditions, Division 1 - GENERAL REQUIREMENTS,
More informationINSTALLATION INSTRUCTIONS July 2018
INSTALLATION INSTRUCTIONS July 2018 This Advanced Wall Protection (AWP) product installs with techniques similar to traditional type II vinyl wallcovering, but is a proprietary construction with key performance
More informationProduct Guide Specification
Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat,
More informationDiSorb Diffuser Product Specifications Section Sound Diffuser-Absorber for Ceilings and Walls (DiSorb Diffuser-Absorber)
DiSorb Diffuser Product Specifications PART 1 - GENERAL 1.01 SUMMARY A. This section includes Sound Diffuser-Absorbers for Ceilings and/or Walls. Types include: 1.02 RELATED SECTIONS 1. DiSorb Diffuser-Absorber,
More informationImportant. Installation Instructions. Ricochet Flexible Wall Protection. Ricochet must be installed by experienced Vinyl Wallcovering (VWC) installers
Important installs with techniques similar to traditional type II vinyl wallcovering, but is a proprietary construction with key performance advantages. Ricochet is packaged in 15-yard coreless rolls,
More informationSection HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.
P a g e 1 PART I. GENERAL 1.01 Scope A. Furnish and install SoftWalls HIGH-TENSION Acoustical & Tackable Stretch Fabric Systems B. Related Work Specified Elsewhere: 1.Preparation of a smooth, flat and
More informationNudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS
SECTION 09 7720 FIBERSCORE FIBERGLASS REINFORCED WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Prefinished polyester glass reinforced plastic sheets and adhered to unfinished [gypsum] [cementitous]
More informationACOUSTICAL WALL TREATMENT SECTION 09840
ACOUSTICAL WALL TREATMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Site-fabricated, stretched fabric acoustical wall system built with rigid polymer stretching system to secure fabric over the wall
More informationSECTION VISUAL DISPLAY BOARDS
SECTION 101000 VISUAL DISPLAY BOARDS THIS SECTION IS WRITTEN IN CSI 3-PART FORMAT AND IN CSI PAGE FORMAT; NOTES TO THE SPECIFIER (IN BLUE), SHOULD BE DELETED PRIOR TO PUBLICATION. PART 1 GENERAL 1.01 SUMMARY
More informationA. Work of this Section, as shown or specified, shall be in accordance with the requirements of the Contract Documents.
PART 1 GENERAL 1.1 GENERAL REQUIREMENTS A. Work of this Section, as shown or specified, shall be in accordance with the requirements of the Contract Documents. 1.2 SECTION INCLUDES A. Work of this Section
More informationSECTION VISUAL DISPLAY BOARDS
SECTION 101000 VISUAL DISPLAY BOARDS THIS SECTION IS WRITTEN IN CSI 3-PART FORMAT AND IN CSI PAGE FORMAT; NOTES TO THE SPECIFIER (IN BLUE), SHOULD BE DELETED PRIOR TO PUBLICATION. PART 1 GENERAL 1.01 SUMMARY
More informationGuide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]
Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [09 77 13] or Section [09 84 14] 1.0 GENERAL 1.01 Scope A. Furnish and install GeoTRAK Stretched Fabric Wall System produced
More informationFramed Decorative Panel Systems
Note: This document contains information and notes in hidden text. If you need assistance to view & hide text, instructions are at this link: http://www.marlite.com/hidden-notes-instructions.aspx Delete
More informationSection Wood Veneer Ceiling Planks Linear
Section 095426 Wood Veneer Ceiling Planks Linear PART 1 GENERAL RELATED DOCUMENTS SUMMARY Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1
More informationTRIDENT SEC 04 SECTION SAFETY AND SECURITY FILMS
TRIDENT SEC 04 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS A.
More informationTRIDENT SEC 06 SECTION SAFETY AND SECURITY FILMS
TRIDENT SEC 06 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS A.
More informationInstallation Instructions. Important. Recommended Tools. Palladium Rigid Sheet/Rubrail or Palladium G2 Sheet/Rubrail. Storage
Important Storage Flat sheet - Store Palladium Rigid Sheet in a clean, dry, interior area at temperatures between 50 F and 95 F [10-35 C]. Keep out of direct sunlight. Make sure sheet is well supported.
More informationA. This Section includes the following types of visual display boards: 1. Porcelain enamel markerboards (for liquid chalk).
SECTION 10100 VISUAL DISPLAY BOARDS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationDecorative Fiberglass Reinforced Wall Panels
SECTION 097720 DECORATIVE FIBERGLASS REINFORCED WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Prefinished polyester glass reinforced plastic sheets and adhered to unfinished gypsum wallboard.
More informationFaçade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.
SECTION 09 7710 FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: Decorative ½ / ¾ (13mm/19mm) thick prefinished panel with preengineered attachment clip along with hardware
More informationSECTION DOOR AND WALL PROTECTION
PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 10 26 00 DOOR AND WALL PROTECTION A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification
More information5GLOBAL. specification guide summary PART 1 GENERAL
This MANU-SPEC utilizes the Construction Specifications Institute (CSI) Manual of Practice, including MasterFormat, SectionFormat, and PageFormat. A MANU-SPEC is a manufacturerspecific proprietary product
More informationMarlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.
Note: This document contains information and notes in hidden text. If you need assistance to view & hide text, instructions are at this link: http://www.marlite.com/hidden-notes-instructions.aspx Delete
More informationGigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
More informationAcrylitex Interior Texture and Coating Submittal Documentation
Acrylitex Interior Texture and Coating Submittal Documentation Project: Contractor: Installer: Supplier: John Wagner & Associates dba Grabber Construction Products 866-237-GRAB(4722) Distributor: Acrylic
More informationSection Wood Grille Ceiling Panels
Section 095426 Wood Grille Ceiling Panels PART 1 GENERAL RELATED DOCUMENTS Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1 Specification sections
More informationARCHITECTURAL SPECIFICATIONS
ARCHITECTURAL SPECIFICATIONS CIG JAN PRODUCTS LTD VISUAL DISPLAY BOARDS Part 1-General 1.01 RELATED DOCUMENT A. The provision of the General Conditions. Supplementary Conditions and the Sections included
More information3M Self-Stick Liquid Protection Fabric
3M Self-Stick Liquid Protection Fabric Technical Data December 2018 3M Part Number 3M Part Descriptor 36876 3M Self-Stick Liquid Protection Fabric, 4" x 300, 6 rolls per pack 36877 3M Self-Stick Liquid
More informationMANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationMANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION
STUC-O-FLEX - ELASTOMERIC ACRYLIC FINISH APPLICATION TO PORTLAND CEMENT PLASTER / CONCRETE RENDER MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION 09220-09 24 00 PART 1-GENERAL SCOPE: Manufacturer's
More informationTechnical Service. INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products. This document refers to the following products:
INSTALLATION INSTRUCTIONS FOR TARAFLEX SPORT PRODUCTS over Gypsum base Products This document refers to the following products: Product Width Width Ft. Installation direction Seams treatment Taraflex Surface
More informationTRIDENT S8 DN 35 SECTION SAFETY AND SECURITY FILMS
TRIDENT S8 DN 35 SECTION 08 87 23 SAFETY AND SECURITY FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear, anti-fragmentation protective polymeric film for glass hazard mitigation. 1.2 RELATED SECTIONS
More informationSECTION IMPACT RESISTANT WALL PROTECTION
SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,
More informationeducation healthcare corporate retail hospitality and much more! creating better environments
creating better environments education healthcare corporate retail hospitality and much more! forbo bulletin board solutions Forbo Bulletin Board is the choice for schools, offices and other environments
More informationImpression Graphic panels
Impression Graphic panels Installation Guidelines 6003.I Rev. 02 8/15 Please Read Disclaimers: PLEASE READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION!! These guidelines are provided in good faith to
More informationGuideline Specifications GORDON MARQUIS LINEAR CEILING PANEL SYSTEMS
Guideline Specifications GDON MARQUIS LINEAR CEILING PANEL SYSTEMS Note to Specifier: MARQUIS Systems are a finished decorative/functional product and should be specified per The Construction Specifications
More informationA. Section Mirrors; mirrors for architectural application to receive window film.
1.1 SECTION INCLUDES A. Anti-graffiti window films for glazing systems and mirrors. 1.2 RELATED SECTIONS A. Section 08300 Mirrors; mirrors for architectural application to receive window film. B. Section
More informationA. Meet at Project site <insert number> days before starting installation.
SECTION 074643 - COMPOSITION SIDING PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Engineered wood cladding. 2. Soffit panels. 3. Trim and fascia. 4. Sealant. 5. Weather barrier. 6. Flashing. 1.2
More informationNote: Delete any section below not relevant to this project; add others as required.
Part 1 General 1.1 section includes A. WriteLite B. Related Sections Note: Delete any section below not relevant to this project; add others as required. 1. Section 06 20 00 Finish Carpentry 2. Section
More informationA. Section Mirrors; mirrors for architectural application to receive window film.
PART 1 GENERAL 1.1 SECTION INCLUDES A. Anti-graffiti window films for glazing systems and mirrors. 1.2 RELATED SECTIONS A. Section 08300 Mirrors; mirrors for architectural application to receive window
More informationECHO PHYSICAL SPECIFICATIONS Abrasion Resistance: Up to 36,000 minimum cycles (cotton duck) Roll Size: 50 lineal yards Backing: Acrylic latex with Stain-Guard Fabric Width: 54 untrimmed Composition: 65%
More informationQUOTE DOCUMENTS FOR HOYT MIDDLE SCHOOL FURNISHING OF MARKERBOARDS East 42 nd Street. Des Moines, Iowa QUOTE # Q6707. Owner
QUOTE DOCUMENTS FOR FURNISHING OF MARKERBOARDS 2700 East 42 nd Street Des Moines, Iowa QUOTE # Q6707 Owner Des Moines Independent Community School District 1917 Dean Avenue Des Moines, Iowa 50316 DES MOINES
More informationRENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION
STUC-O-FLEX RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION 09 97 23 PART 1-GENERAL 1.00 SCOPE: Manufacturer's specifications containing the requirements necessary
More informationBRAMBLE PHYSICAL SPECIFICATIONS Abrasion Resistance: Up to 51,000+ minimum cycles (cotton duck) Roll Size: 50 lineal yards Backing: Acrylic latex with Stain-Guard Fabric Width: 54 untrimmed Composition:
More informationSECTION RESILIENT TILE FLOORING. A. Section includes vinyl composition floor tile and accessories indicated and as specified.
SECTION 09 65 19 RESILIENT TILE FLOORING PART 1 - GENERAL 1.1 SUMMARY A. Section includes vinyl composition floor tile and accessories indicated and as specified. 1.2 SUBMITTALS A. Product Data: Submit
More informationAcrylic/Urethane. Metal Roof Restoration Sample Design Guideline
1 DG0009-I 04/2017 Metal Roof Restoration Sample Design Guideline Acrylic/Urethane ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax: 972-554-3939 www.itwsealants.com
More informationASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS
ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS Re-Ply Roofing Systems Application Specification # AC-2014-A & MB-15 (15 Year Material & Labor Warranty) PART I - GENERAL 1.01 DESCRIPTION
More informationSeries 3000 Pocket Doors
Series 3000 Pocket Doors Introduction: The following three (3) part specification offers the Standard and Optional features for the Series 3000 Pocket Doors. The yellow highlighted areas in the specification
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationSECTION RESILIENT SHEET FLOORING
SECTION 09 65 16 RESILIENT SHEET FLOORING SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1.
More informationWallflowers RUBBER WALL BASE
Product Description Flexco Rubber Wall Base is a true, 100% thermoset (TS) rubber wall base. wall base is incredibly durable, allowing it to stand up to a wide range of use when compared to vinyl wall
More informationGigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application to Insulated Concrete Forms (ICF) Interior Walls
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated Plaster for Direct Application
More informationPALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.
PART 1 GENERAL PALISADE PD 40 SECTION 08 87 13 SOLAR CONTROL FILMS 1.1 SUMMARY A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control. 1.2 RELATED SECTIONS A. Section 08
More informationGigaCrete Specification PlasterMax
GigaCrete Inc. 6775 Speedway Blvd. Suite M105 Las Vegas, NV 89115 Ph (702) 643-6363 Fax (702) 643 1453 www.gigacrete.com GigaCrete Specification PlasterMax PlasterMax : Fire Rated, Abuse Resistant Interior
More informationReflectiClean Acrylic/Urethane
1 DG0009-J 08/2015 Metal Roof Restoration Sample Design Guidelines ReflectiClean Acrylic/Urethane ITW POLYMERS SEALANTS NORTH AMERICA, INC. 111 S. Nursery Road. Irving, TX 75060 Tel: 972-438-9111 Fax:
More informationLINEAR METAL CEILINGS Section
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
More informationSECTION SOUND-ABSORPTIVE PANELS
SECTION 09 77 23 SOUND-ABSORPTIVE PANELS PART 1 - GENERAL 1.1 CONDITIONS AND REQUIREMENTS A. The General Conditions, Supplementary Conditions, and Division 01 General Requirements apply. 1.2 SECTION INCLUDES
More information1. High bay shelving units, fabrication and installation including leveling.
SECTION 10 56 13 - HIGH BAY SHELVING * ALL FIELDS IN [ ] MUST BE EDITED. PART 1 - GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationInstallation ECOWORX / ECOLOGIX INSTALLATION 1. CONDITION YOUR SITE AND TEST 2. PREPARE THE FLOOR
ECOWORX / ECOLOGIX INSTALLATION Notice: For best results review the following guidelines prior to installation. Shaw will not be responsible for improper installation and failure to follow these guidelines
More informationSECTION ACOUSTICAL PLASTER CEILINGS
SECTION 098316 ACOUSTICAL PLASTER CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION SECURITY PROTECTION PART 1 GENERAL
SECTION 13 1010 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Bullet Resistant Aluminum Windows. B. Bullet Resistant Transaction Equipment. C. Bullet Resistant Speakers. D. Bullet Resistant Glazing. E. Bullet
More informationNeed help? Give us a call.
Need help? Give us a call. Call our support line at 1.800.765.6699 if you are unclear on any step of the application. You ll be helped by an experienced professional painter, just like you. WEB: www.zolatone.com
More informationSECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection
SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION
More informationSECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL
SECTION 09511 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 DESCRIPTION: A. Work under this section is subject to requirements of the Contract Documents including the General Conditions and Supplementary
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationEPDM SINGLE-PLY SYSTEM SUMMARY
EPDM SINGLE-PLY SYSTEM SUMMARY This is a generic summary of EDGE s more detailed EPDM SINGLE-PLY SYSTEM SPECIFICATION. For warranty purposes, Approved Applicators are responsible for studying, understanding,
More informationDIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS
DIVISION 10 SPECIALTIES SECTION 10 22 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationAcrylitex Tilt UP Primer Guide Specification Revised August 1, 2008
Acrylic Technologies, Inc. Telephone (503) 653.4061 Fax: (503) 552.1441 Website: www.acrylitex.com Specifier Note: This manufacturer's guide specification specifies Acrylitex Tilt UP Primer for interior
More informationSECTION SELF-ADHERING SHEET WATERPROOFING CCW-711
MANUFACTURER S GUIDE SPECIFICATIONS SECTION 071326 SELF-ADHERING SHEET WATERPROOFING CCW-711 900 Hensley Lane Wylie TX 75098 800-527-7092 www.carlisleccw.com 605401 05.21.13 Carlisle, MiraDRAIN, MiraDRI
More informationSection Special Wall Surfacing
Section 09 77 00 Special Wall Surfacing PART 1: GENERAL 1.01 Summary A. Section Includes: Durable, decorative wall panels with smooth or textured finishes. Mounting hardware, adhesives, accessories and
More informationCON-DEK ICC-ES ESR-2097 SYSTEM
CON-DEK ICC-ES ESR-2097 SYSTEM Manufacturer Specifications Waterproof Deck Coating for Above Grade Concrete PART I. GENERAL 1.01 Scope A. Provide all labor, materials and equipment necessary to apply the
More informationSection Wood Veneer Ceiling Tiles Micro Perforated
Section 095426 Wood Veneer Ceiling Tiles Micro Perforated PART 1 GENERAL 1.1 RELATED DOCUMENTS Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 102239 - FOLDING PANEL PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION ACCORDION FOLDING PARTITIONS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 10 22 26.13 ACCORDION FOLDING PARTITIONS SPEC WRITER NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationSECTION EXTERIOR INSULATION AND FINISH SYSTEMS
SECTION 07 24 00 EXTERIOR INSULATION AND FINISH SYSTEMS PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred
More informationSIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION
TORSION SPRING CEILING SYSTEM SPECIFICATION NOTICE: Consult your local Sound Concepts representative or contact Sound Concepts at 204.783.6297 before specifying any optional or custom element as shape,
More informationSECTION RESILIENT ATHLETIC SURFACING. B. Related Sections: Section(s) related to this section include:
CONNOR PowerDrop Page 1 SECTION 09624 RESILIENT ATHLETIC SURFACING PART 1 - GENERAL 1.01 SUMMARY A. Section includes: Resilient athletic surfacing, including [recycled] [virgin] rubber flooring B. Related
More informationInternational Fireproof Technology Inc.
International Fireproof Technology Inc. The Ultimate in Firestop Solutions and Fire Protective Coatings www.painttoprotect.com 949-975-8588 Guide Specifications Alternate Thermal and Ignition Barrier IFRM
More informationACOUSTI-SEAL 900 SERIES TECHNICAL DATA
The Acousti-Seal Paired Panel System. Paired panel systems are usually the answer for straight-line openings that do not require multiple locations or offset storage. Panels are hinged together in groups
More informationSMOOTH SURFACED BUILT-UP ROOFS WITH ARC SEBS REFLECTIVE ROOF COATINGS
1.0 SCOPE SPECIFICATION FOR COATING SMOOTH SURFACED BUILT-UP ROOFS WITH ARC SEBS REFLECTIVE ROOF COATINGS The intention of this specification is to outline the procedures for the application of ARC SEBS
More information(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand
(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand The purpose of this guide specification is to assist the specifier in correctly specifying solid surface wall cladding, shower
More informationASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS
ASTEC Re-Ply Roof System for ASPHALT & MODIFIED BITUMEN ROOFS Re-Ply Roofing Systems Application Specification # AC - 2010-A & MB PART I GENERAL 1.01 DESCRIPTION A. This guideline specification includes
More informationIndoor Carpet Advertising System Primed White Opaque Base/Clear Velvet Overlaminate
Indoor Carpet Advertising System Primed White Opaque Base/Clear Velvet Overlaminate Aggressive marketers are taking floor advertising a step further by placing advertisements on indoor carpets near their
More informationSERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651
SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651 PART 1 GENERAL 1.1 DESCRIPTION A. Work Included: 1. Furnish all labor and materials to complete the fabrication of detention windows
More informationProtective Industrial Polymers - USA Manufacturer s Specification February 11, 2015
This specification covers InhibiChem SR-GF-L Enhanced Chemical and Solvent-Resistant Glass-Flake Reinforced Steel Tank Lining System. This system consists of a vinyl ester primer, and two troweled coats
More informationNIGHTSCAPE NS05 SECTION SOLAR CONTROL FILMS
NIGHTSCAPE SECTION 08 87 13 SOLAR CONTROL FILMS PART 1 GENERAL 1.1 SUMMARY A. Optically clear dual reflective, aluminum metallized with Charcoal polyesther film for solar control 1.2 RELATED SECTIONS A.
More informationUNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:
SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. AC: Articulation
More informationSECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING
SECTION 07143 CCW-MIRASEAL @ 120 mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING PART 1 - GENERAL 1.1 SECTION INCLUDES: Installation of waterproofing membrane on surfaces indicated on drawings, consisting
More informationInstallation Instructions for Hercules Rib 52
Page 1 of 5 Installation Instructions These instructions supersede any verbal or written instructions from connexus representatives, and must be followed in order for the warranty to be in effect. Delivery
More information