100 mm. 100 mm. 125 mm. 125 mm. 150 mm. 150 mm C003 C001 C269 C208 C055 C002. Tee Gee. Feather Edge. Shiplap. Open V. Open V.
|
|
- Erik Francis
- 5 years ago
- Views:
Transcription
1
2
3
4
5 150 mm 100 mm 150 mm 100 mm 125 mm 125 mm C002 Shiplap C001 Shiplap C003 Open V C269 Open V C208 Feather Edge C055 Tee Gee
6 C027 Starter trim C028 Wall starter trim C029 Drip starter trim C035 Drip/starter trim for vertical or diagonal planks. C x 15 mm Angle trim C X 8 mm Cover trim C X 15 mm Angle trim C026 Universal channel ST45 C039 Plank top trim C040 Universal channel with batten cover C290/291 Universal two-part trim Flexi-trims ST75 C030 External corner trim for horizontal cladding C292/293 Two-part corner trim
7 125 mm 150 mm 150 mm CO43 Shiplap 150 mm Butt joint cover CO44 Open V 150 mm Butt joint cover C057 Tee Gee/Feather Edge 125 mm Butt joint cover 100 mm 100 mm CO51/052 Two part joint trim CO42 Shiplap 100 mm Butt joint cover C281 Open V 100 mm Butt joint cover CO33 Centre joint trim C061 (10 mm type) 30 x 15 mm Angle ventilator C065 (25 mm type) 60 x 15 mm Angle ventilator
8 Fig. 1 Check height, line and level of starter batten Wall area to be clad Fig. 2 Batten out all perimeters and openings Fixing centres Intermediate battens not shown Fig. 3 Fix intermediate vertical battens at appropriate centres Fig. 4 Use two battens at internal and external corners
9 Starter batten (for white only) Intermediate vertical battens C028 Flashing installed before starter trim 10 mm dia holes between battens Starter batten (for white only) Roof finish C027 flange covers batten Fig. 5 Starter trim C027 ar DPC level Fig. 7 Wall starter trim C028 above flat roof Intermediate vertical battens Intermediate vertical battens 10 mm dia holes between battens Starter batten (for white only) C028 Starter batten (for white only) C029 Window head Plinth Fig. 6 Drip starter trim C029 at window head Fig. 8 Wall starter trim at solid base
10 Vertical batten C291 C040 Starter batten Stainless steel fixing nails C290 Back leg conceals batten edge Fig. 9 C040 Universal channel with batten cover at a vertical termination Insert male trim after all planks and other trims are in place Fig. 11 Two-part trim C290/291 terminating cladding at a reveal C026 Stainless steel fixing nails Vertical battens Fig. 10 Universal channel C026 at cladding reveal C030 Fig. 12 Corner trim C030 at an external angle Longer batten (or double batten) required to ensure secure fixings for batten and trim
11 Note use of wider batten to ensure positive fixing Fig. 13 Two-part trim C292/293 at external corner Fix outer part (female), only after all planks and trims are installed Fix outer part (male), only after all planks and trims are installed Fig. 14 Two-part trim C292/293 at internal corner Batten shaped to fit Fig. 15 Universal channels C026 used back-to-back at external obtuse angled corner Optional Flexi-angle trim
12 Offcut as packing piece Fig. 16 Drip trim C035 at window head with extended soffit board Extended window sill C290/291 Packing Fig. 17 Two-part trim C290/291 at cut plank below window sill
13 End batten Fig. 19 Expansion gap at edge trim Expansion gap Profile covers nails in preceding plank Universal two-part trim Fig. 18 Secret nailing Fig. 20 Standard joint for long runs, using C033 cover trim Expansion gaps Intermediate batten Spacer lugs Matching joint cover Hook engages over profile Expansion gap Fig. 21 Applying joint covers Fig. 22 Rear view of joint cover
14 Area to be clad with vertical planks C035 Expansion gaps Deeper batten 5 m full-length planks Fig.24 Drip trim C035 between lengths of vertical cladding Fig. 23 Battening out C035 plus C068 Angle trim C080 Trimtop nail Fig.25 C035 drip trim in conjunction with angle trim C068 to hide high level batten
15 Packing Fig.26 Use of trim and packings at reveals C026 Extended window cheeks Extended sill C290/291 C040 Fig.27 Use of C040 universal channel with batten cover at vertical terminations No nailing necessary at starter plank Fig.28 Universal two-part trim C290/291 at head of cladding C035 Fig.29 C035 drip trim at window head
16 mm Open V mm Open V Leave expansion gap between plank end and trim 055 Tee Gee ig.30 Profiles suitable for vertical cladding Intermediate battens at 600 mm c/c Use nailing groove Starter plank nsure joints are fully home Check for plumb with spirit level r plumb bob Nail Push home male trim, only after all planks and trims in place Fig.32 Locating starter plank (working right to left) Packing ig.31 Check for plumb every two planks 2-part trim Nail into timber through packing and trim Fig.33 Finishing with a cut plank
17 arter plank cut m full width Nail Universal channel Nail Packing Nail Drip trim Nail g.34 Diagonal plank starter piece ometric view Front elevation Measure length of new plank at overlap position of previous plank Allow 4 mm at both ends for expansion Expansion Gap Two-piece trims Expansion Gap g.35 Cutting intermediate anks to length Packing Last plank fitted over preceeding and nailed through packing Fig.36 Fitting the finishing plank
18 Intermediate battens Counterbattens Air path Air path Air path C061 Ventilation unit Horizontal battens Base starter trim Drip starter trim C065 Ventilation unit Fig.37 C061 Ventilation unit at base of cladding -Ventilated horizontal cladding Fig.38 C065 Ventilation unit at base of cladding -Ventilated vertical cladding Air path Air path Soffit board Intermediate battens extend above trim Soffit board Vertical counterbattens extend above trim 2-part Universal trim Universal trim Horizontal battens Fig.39 Termination at soffit -Ventilated horizontal cladding Fig.40 Termination at soffit -Ventilated vertical cladding
19 vertical battens Breather membrane Insulation Air path Horizontal 600 mm c/c Wall starter trim Air path C061 Angle vent Fig.41 Detail A - Insulation and breather membrane Fig.42 Detail B - Bottom vent detail Detail C air path Eaves ventilator tray Detail A Roof insulation Wall insulation Top batten Detail B Swish eaves ventilation unit air path Fig.44 Detail C - ventilation to eaves Fig.43 General view showing extent of insulation
20 Battens and counter-battens Battens and counter-battens Fig.45 Horizontal plankswith ventilation Fig.47 Vertical plankswith ventilation Vertical battens only Breather membrane Sheathing Insulation between studs Horizontal battens only Vapour control membrane Lining board Fig.46 Horizontal planks Battens must be at same centres as timber studs Fig.48 Vertical planks without ventilation - recommended for white cladding only
21
22 Cellular PVC (PVC-ue) BS 7619: 1993: Type 1- BBA Cert Staffordshire B79 7TF Swish Building Products, Tamworth, C mm Shiplap, horizontal format White Wall starter C028 Two-part universal trim C290/291 Two-part universal trim C290/291 Two-part corner trim C292/293 Not applicable Treated timber battens & counterbattens 25mm x 38mm At the base and head, across intermediate areas, at reveals, openings and changes of direction. Max 600mm for perimeter and intermediate battens Swish 30mm A4 stainless steel nails (C204) Secret fixing via groove in C mm cent res maximum Butt joints, using C042 joint covers over support timber 25mm clear ventilated cavity Swish angle ventilator C065 To BS 4016: 1972 C077 Swish low modulus silicone Not applicable Vent top of cladding through eaves box.
23
24
BOARD OF AGRÉMENT CLADDING CERT.NO.91/2622
Uniclass L511:P7113 CI/SfB (41) Hn7 October 2007 Cladding Products Design & Specification Guide BBA BRITISH BOARD OF AGRÉMENT CLADDING CERT.NO.91/2622 BS 7619 Licence No. KM33730 FM 09180 EMS 513947 The
More informationCladding Products. Design & Specification Guide. Performance and Properties. The Specifier s Choice for Cellular PVC Roofline & Cladding
Uniclass L511:P7113 CI/SfB (41) Hn7 02.16 Performance and Properties Cladding Products Design & Specification Guide FM 09180 EMS 513947 OHS 523157 EMS 620926 BS 7619 Licence No. KM33730 The Specifier s
More informationCladding Products. Design & Specification Guide. Performance and Properties. The Specifier s Choice for Cellular PVC Roofline & Cladding
Uniclass L511:P7113 CI/SfB (41) Hn7 09.18 Performance and Properties Cladding Products Design & Specification Guide FS 681825 EMS 681826 OHS 523157 ENMS 620926 BS 7619 Licence No. KM33730 The Specifier
More informationRange Guide. Design Options in PVC Roofline and Cladding. The Specifier s Choice for Cellular PVC Roofline & Cladding BBA BRITISH BUILDING PRODUCTS
Uniclass L5:P7113 CI/SfB (4-) Hn7 10.08 Range Guide Design Options in PVC Roofline and Cladding BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE NO.91/2620 CERTIFICATE NO.91/2622 BS 7619 Licence No. KM33730 FM
More informationRange Guide. Roofline Cladding Rainwater. Design Options for PVC. The Specifier s Choice for Cellular PVC Roofline & Cladding BUILDING PRODUCTS
Uniclass L5:P7113 CI/SfB (4-) Hn7 10.10 Range Guide Design Options for PVC Roofline Cladding Rainwater The Specifier s Choice for Cellular PVC Roofline & Cladding About Swish The premier brand in cellular
More informationWhere can be used? Is difficult to install? Advantages. and the environment. requires virtually no maintenance! POORLY MAINTAINED TIMBER
enduring facades Advantages No more painting Where can be used? Can be fixed horizontally or Retrofit cladding can be used in any situation where timber might traditionally be used. Ideal for replacing
More informationRange Guide. Roofline Cladding Rainwater. Design Options for PVC. The Specifier s Choice for Cellular PVC Roofline & Cladding BUILDING PRODUCTS
Uniclass L5:P7113 CI/SfB (4-) Hn7 03.17 Range Guide Design Options for PVC Roofline Cladding Rainwater FM 09180 EMS 513947 OHS 523157 EMS 620926 BS 7619 BS 7619 Licence No. KM33730 Licence No. KM508760
More informationRange Guide. Roofline Cladding Rainwater. Design Options for PVC. The Specifier s Choice for Cellular PVC Roofline & Clading BUILDING PRODUCTS
Uniclass L5:P7113 CI/SfB (4-) Hn7 05.13 Range Guide Design Options for PVC Roofline Cladding Rainwater The Specifier s Choice for Cellular PVC Roofline & Clading About Swish The premier brand in cellular
More informationCODE OF PRACTICE FOR THE INSTALLATION OF CELLULAR PVC-U CLADDING SYSTEMS (REF: 349/2 JULY 2009) THE BRITISH PLASTICS FEDERATION 6 BATH PLACE
CODE OF PRACTICE FOR THE INSTALLATION OF CELLULAR PVC-U CLADDING SYSTEMS (REF: 349/2 JULY 2009) THE BRITISH PLASTICS FEDERATION 6 BATH PLACE RIVINGTON STREET LONDON EC2A 3JE TEL: 020 7457 5000 FAX: 020
More informationThe better way to build TM. Installation Manual NAILBASE PANELS
The better way to build TM Installation Manual PANELS November 2018 SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationEdition 8. Specification Guide
Edition 8 Specification Guide Offering a complete solution Wide range of white, coloured and foiled woodgrain PVC-UE roofline boards, window trims and cladding planks. Fascias Soffits Cladding Windowboards
More informationSpecification Guide. May First for innovation The widest range of PVC-U and PVC-UE roofline, cladding and window finishes available in the UK
Specification Guide May 2011 First for innovation The widest range of PVC-U and PVC-UE roofline, cladding and window finishes available in the UK www.kbp.co.uk Contents Contents Technical Windowboards
More informationMATERIAL NUMBERS. Material Number Extended Description 1a. 6 mm or 8 mm thick Rockpanel panels 1b
technical design guide quality in front page 1 MATERIAL NUMBERS relating to the APPLICATION DETAILS Material Number Extended Description 6 mm or 8 mm thick Rockpanel panels 1b Rockpanel Lines T&G 10 mm
More informationSPECIALIST BUILDING PRODUCTS CLADDING SYSTEMS KESTREL PVC-UE CLADDING SYSTEM
Specialist Building Products Ltd t/a KestrelBce APPROVAL INSPECTION TESTING CERTIFICATION Billet Lane Normanby Enterprise Park Normanby Road Scunthorpe North Lincolnshire DN15 9YH Tel: 01724 400440 Fax:
More informationPRODUCT OVERVIEW NOVEMBER NEW Secura flooring sizes on pages 23 and 25
PRODUCT OVERVIEW NOVEMBER 2013 NEW Secura flooring sizes on pages 23 and 25 1 Content page 2: page 6: page 10: page 14: page 18: page 22: page 24: page 27: page 28: Scyon overview Scyon Linea weatherboard
More informationCLADDING INSTALLATION GUIDE
CLADDING INSTALLATION GUIDE CREATE A LASTING IMPRESSION FRIENDLY BUILDING PRODUCT ON THE PLANET INSTYLE TIMBER CLADDING HAS BEEN DEVELOPED TO PROTECT AND BEAUTIFY ANY BUILDING DESIGN OR STYLE. THE FOLLOWING
More informationNational Master Specification (NMS) Section Publisher: Spex.ca Page 1. Approved: RELATED REQUIREMENTS.1 Section [ ].
National Master Specification (NMS) Section 07 21 16 BLANKET INSULATION Publisher: Spex.ca Page 1 Approved: 2014-12-31 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section [ ]. 1.2 REFERENCES.1 CSA Group.1
More informationeternal cladding XWood_2014_10p.indd 1 12/11/ :54:57
eternal cladding Where can be used? can be used in situations where timber might traditionally have been used Facades, Gable Ends, Dormers, Roof Eaves, Undersides of Terraces etc. can all be clad with,
More informationWARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS
WARRANTY PROVIDER ACCEPTED A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS Per: 2006 B.C.B.C. Part 9 DISCLAIMER: THE INFORMATION CONTAINED IN THIS DOCUMENT REPRESENTS CURRENT WOOD FRAME
More informationBENCHMARK Evolution Axis
Sheet List EVO VT 00 B DIRECTION OF PREVAILING WIND VERTICAL PANEL JOINT & FASTENER LOCATIONS DIRECTION OF LAY FACTORY APPLIED WEATHER SEAL CONCEALED PANEL FIXING NOTE: FASTENER NUMBERS DEPEND ON THE ACTUAL
More informationArchitectural Wall Panels (AWP) KS CX/EB/FL/FL-S/ MR/MM/PL/WV KS1000 CW/LV/TL
Architectural Wall Panels (AWP) KS600-1000 CX/EB/FL/FL-S/ MR/MM/PL/WV Insulated Roof & Wall Panels Installation Guide November 2017 Architectural Wall Panel Primary / Main fastener Non-setting gun-grade
More informationConcrete Soffit Direct Fix
Installation Guide Concrete Soffit Direct Fix Recommended Pattern insulation boards may be installed in any pattern. The recommended pattern is a square-set pattern, for simplest and quickest configuration
More informationGRP Flat Roofing Edge Trims
GRP Flat Roofing Edge Trims Compatible with GRP, rigid and flexible polyester, polyurethane, acrylic and alkyd systems. Trim Brochure and Technical Specification Guide General Information The Easy To Use
More informationTYPICAL DETAILS MANUAL
TYPICAL ETAILS MANUAL ETAIL LIST AN ESCRIPTION ETAIL LIST RAWING NUMBER ETAIL NUMBER ETAIL ESCRIPTION ISION 01 ETAIL LIST 101 etail 101 Concrete Slab Edge etailing 102 etail 102 Concrete Set own etailing
More informationNU-WALL EXTRUDED ALUMINIUM CLADDING. Installation Specifications Vertical orientation (over cavity)
September 2014 NU-WALL EXTRUDED ALUMINIUM CLADDING Installation Specifications Vertical orientation (over cavity) 1. NW-V001C; Cavity batten layout 2. NW-V002C; Battening options 3. NW-V002C; Battening
More information12 - V0 CFP-12 PANEL INDEX. Delta Series CONCEALED FASTENED PANELS BUILDING PRODUCTS VERTICAL PANELS
CONCEALED FASTENED PANELS CFP-12 PANEL INDEX 12 - V0 BASE DETAILS HORIZONTAL JOINT DETAIL PARAPET ROOF DETAIL INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL SOFFIT DETAIL WINDOW JAMB DETAIL WINDOW HEAD DETAIL
More informationTechnical Application Guide
Issue 3 - Autumn 2016 Technical Application Guide for, Cladding and Internal Windows Boards Our products are 100% Calcium Organic Quality you can feel www.deeplas.co.uk Index Index Technical Data 4-5 Quality
More informationA Handbook of thermal bridging details incorporating aircrete blocks
A Handbook of thermal bridging details incorporating aircrete blocks Book 2 Thermal bridging solutions for external wall full fill cavity details Prepared for the Aircrete Products Association by the BBA
More informationThe brighter way to insulate
The brighter way to insulate 1200 multi-foil that does what it says Installation instructions The multi-foil system certified to achieve 0.2 when installed according to BBA certificate No 06/4379 100 rafter
More informationRoofline. Windowline. Cladding. Roofline Windowline Cladding. Specification Guide
Windowline Cladding Windowline Cladding Edition 7...the specifier's choice of PVC-UE roofline, windowline and cladding products Specification Guide C o n t e n t s Contents 3 Benefits of PVC-UE & PVC-U
More informationTECHNICAL DATA 4-5 WORKING DATA 6-7. Storage 6 Handling Precautions 6 Thermal Movement 6 Temperatures of use 6 Tools 7 Sealants 7 Maintenance 7
Index TECHNICAL DATA 4-5 Quality & Certification 4 Appearance 4 Physical Characteristics 4 Performance in Fire 4 Biological & Chemical Resistance 5 Environmental Facts 5 GUARANTEES 5 General 5 WORKING
More informationPanel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint. Base Angle. Fasteners to Concrete 24 O/C Base Z Flashing
EXTERIOR BASE DETAIL (FLUSH) EXTERIOR BASE DETAIL (OVERHANG) Base Trim with Panel Clip with (2) ¼ 14 x 2 Fasteners at Each Panel Joint Sealant Marriage Bead to Vertical Panel Joint Above and Below Z Flashing
More informationRoofing and Cladding. ALTERNA NT-slate APPLICATION INSTRUCTIONS 11
Roofing and Cladding ALTERNA NT-slate APPLICATION INSTRUCTIONS 11 DOUBLE COVER SLATE LAYING SYSTEM 1. GENERAL Throughout the world slates have been traditionally laid on millions of roofs in a double cover
More informationMulti-layer Insulation Blanket for Walls
Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification
More informationrockspan installation guide horizontally laid panel
rockspan installation guide horizontally laid panel A 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing face is consistent
More informationeuropanel installation guide horizontally laid panel
europanel installation guide horizontally laid panel A 1. Check all support steelwork has been installed within standard dimensional tolerances. Check that the width of the steel bearing face is consistent
More informationSRP-AirOutshield UV Issued:
SECTION 07276: SRP-AirOutshield UV Ultra Violet (UV) resistant, Vapour Permeable Air Barrier Underlayment and Sheathing Membrane Guide Specification This specification is a guide only and may need editing
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 26 19 20 14 15 22 SOFFIT OUTSIDE CORNER INSIDE CORNER 23 25 24 25 5 27 28 29 16 11 OPENING 17 18 END WALL 21 12 13 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CSH-01 CSH-02 CSH-03 CSH-04 CSH-05
More informationFACE CFP - HORIZONTAL PANELS - OPTION 'B'
- Vertical Transitions 12F - H10.3 VHB TAPE 5.000" 127.0mm 5" FORMED TRANSITION STRIP w/ FLAT FACE CFP - - OPTION 'B' H10.3 CONCEALED FASTENED Panel Index 12F - H0 BASE DETAILS JOINT DETAIL PARAPET ROOF
More informationTECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9
MARKINGWALLING OF SAFETY GLASS SPANDREL CURTAIN PANELS FORMED TO COLDFROM ROOFS STACKED WINDOW 7.2 /25 January ARRANGEMENTS (First Issue) XXXX EXXON QUESTION Which factors should be taken into account
More informationELEVATION FOR DETAIL REFERENCE ONLY
6 7 8 10 OUTSIDE CORNER 19 20 4 5 11 21 22 15 16 13 12 OPENING 14 SOFFIT 18 END WALL 17 INSIDE CORNER 9 6 7 8 ELEVATION FOR DETAIL REFERENCE ONLY CCV-01 CCV-02 CCV-03 CCV-04 CCV-05 CCV-06 CCV-07 CCV-08
More informationELEVATION FOR DETAIL REFERENCE ONLY
#smr_elev 5b SEC 2 8i SEC 2 33 SEC 4 1a SEC 2 37 SEC 4 36 SEC 4 35 SEC 4 SOFFIT FRONT 6d SEC 2 7a SEC 2 SOFFIT REAR INSIDE CORNER (REAR) OUTSIDE CORNER (FRONT) 10a SEC 2 9b SEC 2 4e SEC 2 ELEVATION FOR
More informationmaintenance-free free from painting easy to install Fixing Guide Cedral Click
maintenance-free free from painting easy to install Fixing Guide Cedral Click www.cedralsidings.com CONTENT Step by step guide to installing your Cedral Click façade Required materials and tools 1. Prepare
More informationRoofing and Cladding systems overview Prefabricated zinc tiles
Roofing and Cladding systems overview Prefabricated zinc tiles Prefabricated zinc tiles Roofing and Cladding systems overview 3 Index Main characteristics Square tile Rhomboid tile Pointed fish scale tile
More informationtypical section 1:50 Important:
00 Typical ventilated facade installation mounted with top hat channels onto external walls, awning soffit and fascia. 00 Wall panels are shown in varying heights, having open joints for ventilation of
More informationSite check The timber frame pocket guide
PREVIEW PAGES Site check The timber frame pocket guide Sample pages 2 Frame erection ISBN 978-1-909594-65-4 First published in 2018 This is a technical publication for professionals in the built environment
More informationInstallation instructions Thin, flexible multi-foil insulation
The original BBA certified multi-foil Installation instructions Thin, flexible multi-foil insulation Below rafter 0.18 solutions Below 100 rafter + 70 foiled 70 foiled 165.5 spacer batten min 10 38 batten
More informationDesign Manual Fascia, suspended Tray Panels - Vertical Panel Layout
Design Manual Fascia, suspended Tray Panels - Vertical Panel Layout Part Description Page. Extruded Sections and Accessories Page. -. Examples Page.0 -.0 Description Aesthetically attractive ALUCOBOND
More informationConstruction details:
Extension Specifications, 23 Nightingale Avenue Floor area (internal): 27.6m 2 Gross floor area: 31.9m 2 Construction details: Walls Construction from inside: (Option A) wet plaster (airtightness layer
More informationPRODUCT OVERVIEW. The defined rib and flat tray system provides a uniquely elegant appearance.
NAIL STRIP PANEL PRODUCT OVERVIEW Architectural Panel Systems Nail Strip panels are a modern solution for contemporary and heritage style wall cladding, facades and roofing projects. The defined rib and
More informationA durable appearance. Invest better; invest green. External Insulation Concept
Fortex is a range of innovative cladding products that couple the benefits of lowmaintenance PVC with the authentic look and feel of real timber. The products have an attractive textured woodgrain effect
More informationINSTALLING WATER-RESISTIVE BARRIERS & FLASHING
INSTALLING WATER-RESISTIVE BARRIERS & FLASHING IN A TWO-LAYER STUCCO APPLICATION Fortifiber Building Systems Group provides this guide to assist installers by demonstrating a two-layer installation of
More informationCavity Tray Application
Cavity Trays Cavity Tray Block Cavity Trays Page 4 Door & Window Cavity Trays Page 8 Lead Chimney Trays Page 9 Inter-loc Horizontal Cavity Trays Page 7 Lintel Cavity Trays Page 8 Brick Cavity Trays Page
More informationTypical detail: New roof with breathable underlay
New roof with breathable underlay 6. WALLTITE CL00 insulation to achieve target U-value. Vapour control layer. Plasterboard and skim. Unventilated air space 5. WALLTITE returned to insulated cavity stop
More informationResysta Wall Cladding Installation Guidelines
Resysta Wall Cladding Installation Guidelines NOTE: Proper planning of the wall cladding layout is essential for ease of installation of wall cladding boards and wall cladding components. Thoroughly read
More informationINTERLOCKING PANELS by ARCHTECH
INTERLOCKING PANELS by ARCHTECH INTRODUCTION The panels are simply connected by the use of an interlocking groove, giving the elegant appearance of a recessed joint. Interlocking Panels does not require
More informationTEST REPORT. Bushfire resistance test of an external wall system to BAL A40 in accordance with AS EWFA Report No:
TEST REPORT Bushfire resistance test of an external wall system to BAL A40 in accordance with AS1530.8.1-2007 EWFA Report No: 38031900.1 Report Sponsor: Ullrich Aluminium PO BOX 246 Carole Park QLD 4300
More information* Other widths available upon request. 24 Gauge Galvalume - Standard Surface. Other gauges and aluminium available upon request.
is a concealed fastener architectural standing seam roof panel. The panels are easily installed over decking, utilizing metal clips. panels are ideally suited for decorative mansard, fascia and roofs.
More informationContents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2
Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation
More informationGAF EnergyGuard Polyiso Wall Sheathing
From: Technical Services May 15, 2013 GAF EnergyGuard Polyiso Wall Sheathing GAF s EnergyGuard Polyiso Wall Sheathing is intended to be installed on residential construction only. Application types include:
More informationBasic Suspension Systems
CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system
More informationDuPont RainVent Batten Installation Guidelines
DuPont RainVent Batten Installation Guidelines Purpose: To improve the ventilation and draining space behind a cladding system or 3-coat stucco system in residential construction. The DuPont RainVent Batten
More informationFor more information on Pictura visit CI/SfB (41) R December New. Pictura. High performance cladding
New CI/SfB (41) R December 2008 Pictura High performance cladding Introduction The new Pictura coating system incorporates an additional surface treatment for Fibre Cement panels. The main characteristic
More informationMulti-layer Insulation Blanket for Walls
Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification
More informationInstallation Guide. Titan Slate. Rev102606
Installation Guide Titan Slate Rev102606 Titan Manufacturing 200 bella citta blvd. Davenport, fl 33897 Phone: (920) 716-1411 Fax: (866) 601-4395 www.titanroofsystems.com This document includes the recommended
More informationAgrément Certificate 00/3772 website: Product Sheet 1
FloPlast Ltd Castle Road Eurolink Business Park Sittingbourne Kent ME10 3FP Tel: 01795 431731 Fax: 01795 431188 Page 1 of 12 Agrément Certificate e-mail: sales@flopast.co.uk 00/3772 website: www.floplast.co.uk
More information130mm CROATIA BOARD 180mm V-GROOVE
Enjoy DecoClad s enduring beauty in the bush, by the beach or in full sun. Effortless to install and maintain, DecoClad is the ultimate in exterior cladding. Pairing aluminium s proven strength and durability
More informationI-Line - Snap-On Feature
Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects
More informationSystem Installation MANUAL
Issue 1 May 2013 System Installation MANUAL Page 1 of 22 Contents IKOslate Installation Manual Contents 1 Introduction IKO Overview 4 IKOslate Product Description 5 Storage Guidelines 5 2 Planning and
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationSiding and Soffit Installation Guidelines
Siding and Soffit Installation Guidelines email web phone 07 46 16 Longboard Siding & Soffit INTRODUCTION INSTALLATION GUIDELINES NOTE: These instructions are prepared for persons experienced in the field
More information1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights
1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights These 1 Exam Prep tabs are based on the 2012 Sheet Metal and Air Conditioning Contractors' National Association, Inc., seventh edition.
More informationSWISH ROOFLINE SYSTEM SWISH CELLULAR PVC-U ROOFLINE SYSTEM
Specialist Building Products Limited APPROVAL INSPECTION TESTING CERTIFICATION Pioneer House Mariner Lichfield Road Industrial Estate Tamworth Staffordshire B79 7TF Tel: 01827 317200 Fax: 01827 317201
More informationWHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.
WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED. Build walls and ceilings with a strong base, sturdy reinforcements and much more with Phillips extensive line of high quality products. As a single source
More informationLUX Specifications. Section S - Preformed Steel Siding
Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of
More informationWeatherSmart Air Barrier Installation Guide
WeatherSmart Air Barrier Installation Guide 1 The intent of this document is to provide a guide for the installation of WeatherSmart as both a Weather Resistive Barrier (W.R.B.) and an Air Barrier Material
More informationDALAL ARCHITECTURAL METAL SOLUTIONS. Roof Covering & Fac ade Cladding
DALAL ARCHITECTURAL METAL SOLUTIONS Roof Covering & Fac ade Cladding Dalal Architectural Metal Solutions is a branch of Dalal Steel Industries designed to realize the visions of architects. Dalal Architecture
More informationMulti-layer Insulation Blanket for
Multi-layer Insulation Blanket for Walls Thermal Insulation in a thin, flexible, multi-layer membrane High performance wall insulation Fully certificated Thermally tested in accordance with EN12667 High
More informationFACADES - ACM BASE AT OVERHANG (WITH BASE FLASHING) INDEX SHEET
KPH-DS-01-MTLV KPH-PJ-01-MTLV KPH-PJ-02-MTLV KPH-PJ-03-MTLV KPH-PJ-04-MTLV KPH-PJ-05-MTLV KPH-BS-01-MTLV KPH-BS-02-MTLV KPH-BS-03-MTLV KPH-BS-04-MTLV KPH-OC-01-MTLV KPH-IC-01-MTLV KPH-SF-01-MTLV KPH-SF-02-MTLV
More informationSLATE-LITE FACADE-SYSTEM:
SLATE-LITE FACADE-SYSTEM: RT D IFIE QUAL Y IT CE The new style of ventilated exterior cladding REAL SLATE Facade-System: Components Accessories Fassaden-System: Bauteile &&Zubehör Decor: Negro (No. #1108100)
More informationFaçade cladding systems overview Flat lock joint
Façade cladding systems overview Flat lock joint Façade cladding systems - Flat lock joint an overview 3 Sistemas de revestimiento - Junta alzada para fachadas Index Main characteristics 5 Principal joints
More informationFaçade Cladding systems overview Angle standing seam
Façade Cladding systems overview Angle standing seam Cladding systems angle standing seam for façades 3 Sistemas de revestimiento - Junta alzada para fachadas Index Main characteristics 5 Principal joints
More informationA4/8 PS AW2324D Issue 10 May Permishield
Insulation A4/8 PS AW2324D Issue 10 May 2018 Vapour-permeable INSULATION MEMBRANE 3-in-1 Insulation, thermal break and vapour-permeable sarking Helps achieve a 6-star house energy rating Fibre-free, non-allergenic,
More informationEdition 3 - March 2011
Specification Guide Edition 3 - March 2011 C o n t e n t s Contents 3 Benefits of PVC-UE & PVC-U 4 Roofline Range and Colours 5 Fascia Details 7 Bardgeboard Details 8 Roofline Range 9 Design Considerations
More informationInstallation Guide. IMPORTANT: Read all sections before starting. For the most up-to-date information, visit our website: leadvisioninternational.
Installation Guide IMPORTANT: Read all sections before starting. For the most up-to-date information, visit our website: leadvisioninternational.com Before installing a composite wall cladding, it is recommended
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationPacific Tile Counter Batten and Batten
Pacific Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com Page2 INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationTruGrain 12 Inch Commercial Profile Installation Recommendations
TruGrain 12 Inch Commercial Profile Installation Recommendations o Delivery, Storage and Handling o General Requirements o Application of Stain & Sealer o Storage and Handling (Post-Treatment) o Installation
More informationSpecifications. Some details shown in this document have been reproduced from CCANZ document CP 01.
BRICKVENEERS Specifications Bowers Brick Veneer meets the requirements of AS/NZS 4455 as a masonry brick veneer and complies with and exceeds the 15 year durability requirements as stated in the New Zealand
More informationExternal timber cladding
EXTERNAL TIMBER CLADDING External timber cladding the definitive professional guide for cladding designers, builders and installers illustrated with more than 100 colour photographs and drawings researched
More informationC O M M E R C I A L A R C H I T E C T U R A L
Series 466 Awning / Casement Window C O M M E R C I A L A R C H I T E C T U R A L DESIGN FEATURES This 102mm thick commercial grade awning window has been designed with bold frame lines and thick (strong)
More informationGuidance on U Values from Domestic Heating Design Guide
Guidance on U Values from Domestic Heating Design Guide The following U Values are from the Domestic Heating Design Guide, and the complete publication is available for purchase from members of the Domestic
More informationClassic and NB Tile Counter Batten and Batten
Classic and NB Tile Counter Batten and Batten INSTALLATION GUIDE www.gerardusa.com INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation
More informationTABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers
version 2.5 updated as of 08.04.2017 2 TABLE OF CONTENTS 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers 2.0 ASSEMBLY 2.1 Sequence of Assembly 2.2 Preparation
More informationMulti-layer Insulation Blanket for Walls
Multilayer Insulation Blanket for Walls Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 High performance wall insulation Full Agrément certification
More information