THIS TO CERTIFY THAT SWISS KRONO OSB. Structure for flooring, roof decking and wall sheathing.

Size: px
Start display at page:

Download "THIS TO CERTIFY THAT SWISS KRONO OSB. Structure for flooring, roof decking and wall sheathing."

Transcription

1 Certification Body: ABN: JAS-ANZ Accreditation No. Z AK PO Box 7144, Sippy Downs Qld (07) Certificate Holder: SWISS KRONO GmbH Wittstocker Chaussee Heiligengrabe Ph: +49(0)33962/ Type and/or use of product: The product is certified for use as flooring, roof decking, structural wall bracing and sheathing on timber frame dwellings in dry and humid applications. Performance Requirement(s) Volume One BP1.1 (a), (b) i, ii, iii THIS TO CERTIFY THAT SWISS KRONO OSB Description of product: Certificate number: CM40089 Rev2 SWISS KRONO OSB is an engineered wood particle board constructed using formaldehyde free binders and natural wood strands. Panel thicknesses range from 6mm to 40mm. COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S) BCA 2016 Structure for flooring, roof decking and wall sheathing. Volume Two P2.1.1 (a), (b) i, ii, iii Deemed-to-Satisfy Provision(s): Not applicable for this product Not applicable for this product State or territory variation(s): Not applicable for this product Not applicable for this product Structure for flooring, roof decking and wall sheathing. SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B Limitations and conditions: 1. Installation must be performed by a suitably qualified tradesperson in accordance with SWISS KRONO GmbH Installation instructions OSB Installation Manual June Suitable for use as Structural bracing where the panel -in service moisture content does not exceed 20% 3. Timber structures supporting the panel must be designed and constructed in accordance with AS1684.2:2010 and AS1684.3:2010 as applicable. 4. The board must be laid in a dry condition after all wet site operations have been completed. Damp-proof membranes and vapour control layers should be incorporated as necessary in accordance with relevant standards. 5. Minimum board thickness of 9mm for pitched roofs, 11 mm for flat roofs without access (except maintenance) and 15mm for flat roofs with access must be used. 6. Fixings used to attach boards to timber structure must be appropriate for the wind region of the building. Building classification/s: 1,2,3,4,5,6,7,8,9 & 10 John Thorpe - CMI Don Grehan Unrestricted Building Certifier Date of issue: 14/11/2017 Date of expiry: 24/07/2020 Certificate number: CM40089 Rev2 This certificate is only valid when reproduced in its entirety. Page 1 of 7

2 7. Due to condensation, the board must not be used as flat roof decking to buildings where insulation occurs above the supporting deck. 8. SWISS KRONO OSB should be treated as conventional plywood sheathing with regard to detailing at openings, eaves and sole plate, the fixing of wall ties and breather paper, and the effect of openings on racking strength. 9. Where weather resistance is required, a waterproof material must be installed over the panels in accordance with the relevant standards. 10. Movement gaps must be provided between panels to allow expansion due to moisture and temperature. 11. This Certificate is issued based on the evidence of compliance as detailed herein. Any deviation from the specifications contained in this Certificate is outside of this document s scope and the installation of the certified product/system will not be covered by this CodeMark certification. This may result in the product being classified as a non-conforming building product/system. Scope of certification: The CodeMark Scheme is a building product certification scheme. The rules of the Scheme are available at the ABCB website This Certificate of Conformity is to confirm that the relevant requirements of the Building Code of Australia (BCA) as claimed against have been met. The responsibility for the product performance and its fitness for the intended use remain with the certificate holder. The certification is not transferrable to a manufacturer not listed on Appendix A of this certificate. Disclaimer: The Scheme Owner, Scheme Administrator and Scheme Accreditation Body do not make any representations, warranties or guarantees, and accept no legal liability whatsoever arising from or connected to, the accuracy, reliability, currency or completeness of any material contained within this certificate; and the Scheme Owner, Scheme Administrator and Scheme Accreditation Body disclaim to the extent permitted by law, all liability (including negligence) for claims of losses, expenses, damages and costs arising as a result of the use of the product(s) referred to in this certificate. Certificate number: CM40089 Rev2 This certificate is only valid when reproduced in its entirety. Page 2 of 7

3 APPENDIX A PRODUCT TECHNICAL DATA A1 Type and intended use of product As per page one. A2 Description of product SWISS KRONO OSB/3 board comprises softwood flakes/strands bonded together with MUPF (melamineurea- phenolic) resin, MDI (diisocyanate diphenylmethane) binder and waxes. The board is manufactured to the specification detailed in BS EN 300: 1997 for OSB/3, loadbearing oriented strand boards for use in humid conditions. The board is produced in standard sizes (1) of: thickness (mm) 6, 9, 11, 15, 18 and 22 length x width (mm) 2440 x 1220 The nominal density of the board is 630 kgm 3. The board is available with square or tongue-and groove edges. A3 Product specification Performance Characteristics STRUCTURAL NON-STRUCTURAL Internal/Dry Internal (Humid) Exterior Floors, Internal Dry Internal Exterior Walls/ Roofs Humid EN Clause No. Bending strength Bending stiffness Internal bond (Tensile strength) Durability (Swelling in thickness) Durability (moisture resistance) Release of formaldehyde Reaction to fire (AoC 2+ or 3 (4)) Water vapour permeability Airborne sound insulation Sound absorption Thermal conductivity Bending strength & stiffness for structural use Impact resistance for structural use Certificate number: CM40089 Rev2 This certificate is only valid when reproduced in its entirety. Page 3 of 7

4 Strength & stiffness under point load Mechanical durability Biological durability PCP content Notes: Shaded boxes - Performance characteristics that must be determined Non-shaded boxes - Performance characteristics determined only if required 2 End-use applications under humid conditions only 3 Structural floor or roof decking on joists only 4 Strength/stiffness in tension & compression, panel shear (modulus of rigidity), panel shear, planar shear (modulus of rigidity), planar shear strength A4 Manufacturer and manufacturing plant(s) This field is voluntary. For more information, please contact Certificate Holder. A5 Installation requirements Installation must be performed by a suitably qualified tradesperson in accordance with SWISS KRONO GmbH Installation instructions OSB Installation Manual June For installation as a structural bracing the SimBrace Oriented Strand Board installation guide 2016 is to be followed When installed as structural wall bracing the following is applicable: 1. Suitable for use as Structural bracing where the panel -in service moisture content does not exceed 20%. 2. To be installed in accordance with the requirements of AS1684.2: Recommended Nails screws and staples 2.8mm diameter x30mm flathead galvanised or corrosion resistant nails, or their gun driven equivalent are in accordance with AS Minimum edge clearance for fasteners is 7mm. 5. The spacing for staples are two thirds (i.e. fastener spacing multiplied by 0.66) those shown for nails or screw. Indicative fixing of structural wall bracing: Type Model Specifications Hand Driven Nails* Flathead structural clouts or connector nails 2.80mm x 30mm Power Driven Nails Senco TN22-38 APB 2.33mm x 38mm flathead Bostitch AC45P-250-GW 2.5mm x 45mm flathea Jambro B20998 RBC 2.80mm x 32mm zinc plate barb Duo-Fast C27.32GD 2.7mm x 32mm Galvanised Power Driven Staples Senco N167 BAB - Bostitch BCS Jambro A10617 G mm Certificate number: CM40089 Rev2 This certificate is only valid when reproduced in its entirety. Page 4 of 7

5 * If smaller diameter hand driven nails are used, the spacing of nails can be reduced in the ratio of the basic lateral loads per nail for J4 or JD4 joint group given in Table 4.1 of AS Timber Structures - Design Methods for the lower nail diameter relative to the tabulated load for a 2.8mm diameter nail. Source: Certification Holder Flooring SWISS KRONO OSB/3 is suitable for use as domestic or commercial flooring. The board should be laid in a dry condition after all wet site operations have been completed. Dampproof membranes and vapour control layers should be incorporated as necessary. Although temporary exposure to the elements is permissible during installation, this must be for the shortest possible period. If wetted, the boards must be allowed to dry out thoroughly before applying any floor coverings or surface coatings, or subjecting the boards to the full design load. Certificate number: CM40089 Rev2 This certificate is only valid when reproduced in its entirety. Page 5 of 7

6 When used in high risk areas, such as kitchens and bathrooms, the board, in common with other wood and wood-based products, should be protected from wetting, for example, by providing a continuous waterproof covering, turned up and sealed at junctions with walls, and where services pass through the floor. A6 Other relevant technical data Behaviour in relation to moisture In common with all timber products OSB is subject to moisture movement. As a guide, an increase in moisture content of 1% increases the length and width of a board by 0.3 mm per metre run. Under the same environmental conditions OSB will take longer to equilibrate and will attain an equilibrium moisture content some 2% to 3% lower than solid timber. To avoid distortion and damage to finishes, movement gaps, should be provided when installing the board. To minimise subsequent movement, before installation the board should be conditioned as close as is practicable to the environmental conditions likely to occur in service. Durability In common with other wood-based panels, the board is likely to lose strength and stiffness, and be susceptible to fungal attack, when subjected to prolonged high humidity or wetting, care should be taken in designing, detailing and constructing buildings to ensure that moisture does not accumulate within the board. Certificate number: CM40089 Rev2 This certificate is only valid when reproduced in its entirety. Page 6 of 7

7 APPENDIX B EVALUATION STATEMENTS B1 Evaluation methods 1. Structural Provision A2.2 (a) (i) & (iii) and (a) (i) & (iii). Reports from NATA accredited test laboratories and certificates from Professional Engineer. B2 Reports 1. British board of Agreement, Agrement Certificate No. 04/4093 Demonstrates compliance to Structure. 2. Deutsches Institut Fur Bautechnik DIBt National Approval Z , Approval Agency for Building Products and Constriction Methods. Dated 27/02/2012 Complies with Structural provision. 3. Deutsches Institut Fur Bautechnik DIBt National approval ETA , Approval Agency for Building Products and Constriction Methods. Dated 26/06/2013 Complies with Structural provision. 4. Report from HFB Engineering. conformity to EN 13986; 2004 Wood-based panels for use in construction Characteristics, evaluation of conformity. 5. Declaration of Performance KDE_OSB/3_CPR_2013_001_UK Manufactures declaration of compliance under EU directive 305/ Declaration of Performance - KDE_OSB/F****_CPR_2013_UK. The Certificate Holder has chosen not to make the above evidence of compliance publicly available, due to the documents being considered commercial in confidence. Certificate number: CM40089 Rev2 This certificate is only valid when reproduced in its entirety. Page 7 of 7

Hebel PowerPanel for House & Low Rise Multi-Residential External Wall

Hebel PowerPanel for House & Low Rise Multi-Residential External Wall Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: CSR Hebel ABN: 55 008 631 356 Triniti

More information

THIS TO CERTIFY THAT. Firetek Panel. Structure - Structural Reliability

THIS TO CERTIFY THAT. Firetek Panel. Structure - Structural Reliability Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Building Solutions Pty Ltd ABN: 22

More information

THIS TO CERTIFY THAT. Ritek Roof Panels. Structure - Structural Reliability

THIS TO CERTIFY THAT. Ritek Roof Panels. Structure - Structural Reliability Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Building Solutions Pty Ltd ABN: 22

More information

THIS TO CERTIFY THAT. Euro Selekta Clad

THIS TO CERTIFY THAT. Euro Selekta Clad Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Type and/or use of product: Internal and external cladding

More information

ResCom Board BCA Certificate number: CM40009 Rev6. Date of issue: 22/12/2017. Don Grehan Unrestricted Building Certifier

ResCom Board BCA Certificate number: CM40009 Rev6. Date of issue: 22/12/2017. Don Grehan Unrestricted Building Certifier Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: ABN: 47 151 952 742 3 Allen Street

More information

Superwall / Hydrowall System

Superwall / Hydrowall System Certification Body: THIS TO CERTIFY THAT Certificate number: CM40085 ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Type

More information

BioFilm Termite Management System

BioFilm Termite Management System Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: PC Plastics Pty Ltd ABN: 81 164 968

More information

Certificate number: CM40087 Rev3

Certificate number: CM40087 Rev3 Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: ABN: 22 750 783 065 19 Lowermill Rd,

More information

Luxwood Building System

Luxwood Building System Certificate number: CM40214 THIS TO CERTIFY THAT Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate

More information

BondorPanel. Structural Reliability &(b)(i),(ii), (iii) & (c)

BondorPanel. Structural Reliability &(b)(i),(ii), (iii) & (c) Certification Body: THIS TO CERTIFY THAT Certificate number: CM40189 Rev1 ABN: 80 111 17 568 JAS-ANZ Accreditation No. Z445010AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 199 www.certmark.org Certificate

More information

KORDON TERMITE SYSTEM

KORDON TERMITE SYSTEM Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Bayer CropScience Pty Ltd T/A Bayer

More information

THIS TO CERTIFY THAT. FlameGuard

THIS TO CERTIFY THAT. FlameGuard Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Metecno Pty Ltd ABN: 44 096 402 934

More information

KORDON TERMITE SYSTEM

KORDON TERMITE SYSTEM Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Type and/or use of product: KORDON

More information

Certificate number: CM40175 Rev4

Certificate number: CM40175 Rev4 Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Type and/or use of product: HomeGuard Precision is a Termite

More information

Pronto Panel Multi-storey Internal Wall & Low-rise Intertenancy Wall System

Pronto Panel Multi-storey Internal Wall & Low-rise Intertenancy Wall System Certificate number: CM30050 Rev3 Global-Mark Pty Ltd, Suite 4.07, 32 Delhi Road, North Ryde NSW 2113, Australia Tel: +61 (0)2 9886 0222 - www.global- Mark.com.au Certificate Holder: Brickworks Building

More information

Certificate number: CM40079 Rev 5

Certificate number: CM40079 Rev 5 Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Fairview Architectural ABN: 56 111

More information

ECO Wall & Floor Panels

ECO Wall & Floor Panels Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Chad Group Australia Pty Ltd ABN:

More information

Certificate number: CM40025 Rev1

Certificate number: CM40025 Rev1 acertification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Raydiate Pty Ltd ACN: 113 013 693

More information

Certificate number: CM40002 Rev3 THIS TO CERTIFY THAT Plasmite Reticulation Anti-Termite Management System

Certificate number: CM40002 Rev3 THIS TO CERTIFY THAT Plasmite Reticulation Anti-Termite Management System Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: Creepy Crawly Pest Control Pty Ltd.

More information

CSR Cemintel Territory Series Wall Cladding System

CSR Cemintel Territory Series Wall Cladding System Certificate number: CM30048 Rev4 Global-Mark Pty Ltd, Suite 4.07, 32 Delhi Road, North Ryde NSW 2113, Australia Tel: +61 (0)2 9886 0222 - www.global- Mark.com.au Certificate Holder: CSR Building Products

More information

KOOLTHERM K12 FRAMING BOARD AND K15 RAINSCREEN BOARD BCA Certificate number: CM Date of issue: 15/08/2017. Date of expiry: 21/03/2020

KOOLTHERM K12 FRAMING BOARD AND K15 RAINSCREEN BOARD BCA Certificate number: CM Date of issue: 15/08/2017. Date of expiry: 21/03/2020 Certification Body: SAI Global Certification Services Pty Limited (ACN 108 716 669) Trading as SAI Global JAS-ANZ Accreditation No. Z1440295AS Address: 680 George Street, Sydney, NSW 2000 Website: www.saiglobal.com

More information

Earthwool Glasswool Insulation

Earthwool Glasswool Insulation Global-Mark Pty Ltd, Suite 4.07, 32 Delhi Road, North Ryde NSW 2113, Australia Tel: +61 (0)2 9886 0222 - www.global-mark.com.au Certificate Holder: Knauf Insulation Pty Ltd Unit 2 44 Borthwick Avenue Murarrie,

More information

NRG Greenboard Insulated Wall Cladding System

NRG Greenboard Insulated Wall Cladding System Certificate number: CM30005 Rev11 Global-Mark Pty Ltd, Suite 4.07, 32 Delhi Road, North Ryde NSW 2113, Australia Tel: +61 (0)2 9886 0222 - www.global-mark.com.au Certificate Holder: MFT Holdings QLD Pty

More information

SMARTPLY WOOD-BASED PANEL SMARTPLY OSB/3 FOR FLOORING

SMARTPLY WOOD-BASED PANEL SMARTPLY OSB/3 FOR FLOORING SmartPly Europe Ltd Belview Slieverue Waterford Ireland Tel: 00 353 51 851233 Fax: 00 353 51 851130 e-mail: info@smartply.com website: www.smartply.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Exotec Facade Panel and Fixing System

Exotec Facade Panel and Fixing System Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Type and/or use of product: External Façade Panel and

More information

Velux Sun Tunnels TWR & TWF

Velux Sun Tunnels TWR & TWF Certification Body: Global-Mark Pty Ltd, Suite 4.07, 32 Delhi Road, North Ryde NSW 2113, Australia Tel: +61 (0)2 9886 0222 - www.global- Mark.com.au Certificate Holder: Velux Australia Pty Ltd 78 Henderson

More information

THIS TO CERTIFY THAT. TERM-seal Systems. Volume One 2016 (Amdt. 1) Volume Two 2016

THIS TO CERTIFY THAT. TERM-seal Systems. Volume One 2016 (Amdt. 1) Volume Two 2016 Certification Body: ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Certificate Holder: TERM-seal Pty Ltd ABN: 92104603983

More information

DANPALON POLYCARBONATE ROOF AND WALL SHEETING SYSTEMS

DANPALON POLYCARBONATE ROOF AND WALL SHEETING SYSTEMS Certification Body: SAI Global Certification Services Pty Limited (ACN 108 716 669) Trading as SAI Global JAS-ANZ Accreditation No. Z1440295AS Address: 680 George Street, Sydney, NSW 2000 Website: www.saiglobal.com

More information

COFORD 2018 WOOD TECHNOLOGY IRELAND. NO.

COFORD 2018 WOOD TECHNOLOGY IRELAND. NO. COFORD 2018 WOOD TECHNOLOGY IRELAND. NO. 8 Key points EN 13986 Wood-based panels for use in construction is the European standard covering wood-based board materials including plywood. It is a harmonised

More information

Specifying wood-based panels for structural use

Specifying wood-based panels for structural use CI/SfB Ri4 + j1 + j7 Uniclass L6617 + L6618 Wood Information Sheet WIS 2/3-57 Subject: Panels Revised: June 2016 Specifying wood-based panels for structural use This Wood Information Sheet (WIS) covers

More information

Other quality certification includes SINTEF (Norway) and SmartPly OSB is manufactured in accordance with the

Other quality certification includes SINTEF (Norway) and SmartPly OSB is manufactured in accordance with the SmartPly OSB 3 Data Sheet 22nd April 2013 copy:smartply OSB 2 10th Jan 8/5/13 14:25 Page 3 SMARTPLY SmartPly OSB3 SmartPly OSB3 is a highly engineered, moisture resistant load-bearing panel designed for

More information

EGGER OSB 4 TOP HIGH-PERFORMANCE AND SUSTAINABILITY FOR ELEVATED WOOD CONSTRUCTION REQUIREMENTS.

EGGER OSB 4 TOP HIGH-PERFORMANCE AND SUSTAINABILITY FOR ELEVATED WOOD CONSTRUCTION REQUIREMENTS. EGGER OSB 4 TOP HIGH-PERFORMANCE AND SUSTAINABILITY FOR ELEVATED WOOD CONSTRUCTION REQUIREMENTS www.egger.com/buildingproducts HIGH-PERFORMANCE SUSTAINABILITY 100% FORMALDEHYDE-FREE BONDING WITH BUILDING

More information

SUITABILITY: SMARTPLY OSB3 - ZERO ADDED FORMALDEHYDE

SUITABILITY: SMARTPLY OSB3 - ZERO ADDED FORMALDEHYDE SMARTPLY OSB3 is a highly engineered, moisture resistant load-bearing panel designed for use in humid conditions and is therefore ideal for many structural and non-structural applications in both internal

More information

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE DECLARATION OF NO. MW/PW/421-001/CPR/DOP 1 (5) 1. PRODUCT-TYPE: Metsä Wood structural spruce plywood - Uncoated or overlaid (phenol or melamine film) - Phenol-formaldehyde adhesive (exterior gluing quality)

More information

Velux Roof Windows GGL & GPL, incorporating EDW Flashing Kits

Velux Roof Windows GGL & GPL, incorporating EDW Flashing Kits Certification Body: Global-Mark Pty Ltd Suite 4.07 32 Delhi Road North Ryde NSW 2113 Australia Tel: +61 2 9886 0222 www.global- Mark.com.au Certificate Holder: Velux Australia Pty Ltd 78 Henderson Road

More information

NON DEEMED-TO-SATISFY EXTERNAL WALL CLADDING SYSTEMS

NON DEEMED-TO-SATISFY EXTERNAL WALL CLADDING SYSTEMS Workplace Standards Tasmania Building Control Branch Building Regulation Advisory Note BRAN No. 4 of 2011 Issued: 3 October 2011 NON DEEMED-TO-SATISFY EXTERNAL WALL CLADDING SYSTEMS 1. Introduction In

More information

Velux Skylights FS, VS, VSE & VSS with EDW Flashing Kits plus Skylights FCM, VCM, VCE & VCS with custom Flashing

Velux Skylights FS, VS, VSE & VSS with EDW Flashing Kits plus Skylights FCM, VCM, VCE & VCS with custom Flashing Certification Body: Global-Mark Pty Ltd, Suite 4.07 32 Delhi Road North Ryde NSW 2113 Australia Tel: +61 2 9886 0222 www.global- Mark.com.au Certificate Holder: Velux Australia Pty Ltd 78 Henderson Road

More information

WISA BIRCH PLYWOOD Contre-plaqué Sperrholz. Regulations

WISA BIRCH PLYWOOD Contre-plaqué Sperrholz. Regulations UPM-Kymmene Wood Ltd Victoria House 55 Queen Street Maidenhead Berkshire SL6 1LT Tel: 01628 513300 Fax: 01628 513400 e-mail: woodltd@upm-kymmene.com website: www.wisa.com CI/SfB i4 Agrément Certificate

More information

Declaration of Performance No. SUI/PP/13/CE2+ Product Type 9mm 12mm 15mm 18mm 21mm 24mm 27mm 30mm

Declaration of Performance No. SUI/PP/13/CE2+ Product Type 9mm 12mm 15mm 18mm 21mm 24mm 27mm 30mm Page 1 / 2 Declaration of Performance No. SUI/PP/13/CE2+ 9mm 12mm 15mm 18mm 21mm 24mm 27mm 30mm Intended uses (See page 2) Name and contact address Indústria de Compensados Sudati Ltda. of the manufacturer

More information

CERTIFICATE OF CONFORMITY

CERTIFICATE OF CONFORMITY Product Description CERTIFICATE OF CONFORMITY This is to certify that USG BORAL PARTIWALL INTERTENANCY WALL SYSTEMS Complies with the New Zealand Building Code: 1. B1.3.1, B1.3.2, B1.3.3(a),(b),(c),(f),(i),(l),(o)

More information

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors Part 5 Substructure and ground floors Chapter CONTENTS SCOPE Clause Page DESIGN - General Design standards D1 1 Statutory and other requirements D2 1 Resistance to ground contaminants D3-D4 1 This Chapter

More information

Certificate No: EWWS546

Certificate No: EWWS546 Certificate No: EWWS546 Kingspan TEK Building System Description of Product Kingspan TEK Building System for use as wall and roof panels. The system is a structural insulated panel (SIP) system comprising

More information

FIGURE 1: 30% increase in mechanical resistance compared to OSB3

FIGURE 1: 30% increase in mechanical resistance compared to OSB3 SMARTPLY OSB4 is an extremely high-performance engineered wood panel suitable for the most demanding structural applications in offsite manufacturing and construction. It is manufactured using state of

More information

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide V1/0715/AI/TDO1 KORE Loft Insulated Flooring System Design Guide KORE Loft Insulated Flooring System Key Features Excellent thermal performance for the lifetime of the building Sheets tongue and grooved

More information

Plywood (untreated or H3 treated) must not be allowed to come in contact with soil.

Plywood (untreated or H3 treated) must not be allowed to come in contact with soil. Plyfloor Advantages Superior strength Stiffness of Plyfloor is nearly three times that of particle type boards of the same thickness. This means thinner Plyfloor panels are cost effective floor panels.

More information

9 Revision B

9 Revision B JJI-JOIST TECHNICAL BULLETIN SUBJECT: Ground Floor Design & Restraint Bulletin Number: Date Issued: Sheet 1 of 11 Introduction When designing the ground floor of a residential dwelling using I-Joists,

More information

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2 Contents BCA Codes 3 General 4 Fire Performances Thermal and Acoustic Insulation Wall Installation 4 Timber Frame Separation Walls 5 Steel Frame Separation Walls 6 External Fire Rated Walls 7 Floor Installation

More information

SIP ENERGY STRUCTURAL INSULATED PANEL SYSTEM SIP ENERGY LOADBEARING WALL AND ROOF PANELS

SIP ENERGY STRUCTURAL INSULATED PANEL SYSTEM SIP ENERGY LOADBEARING WALL AND ROOF PANELS SIP Energy Ltd Athenry Co Galway Ireland Tel: 00 353 91 874290 e-mail: info@sip-energy.com website: www.sip-energy.com APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION Agrément

More information

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD. Cl/SfB 1 (4-) RJ7 1 1 1 July 2010 Cempanel BUILDING BOARD CEMENT PARTICLE BOARD Cempanel Class 0 cement particle board with excellent impact, fire and acoustic properties. Its durability, consistently

More information

FasteningSystems Rosenbergsaustraße HEERBRUGG SCHWEIZ EAD This version replaces ETA-13/0699 issued on 13 June 2013

FasteningSystems Rosenbergsaustraße HEERBRUGG SCHWEIZ EAD This version replaces ETA-13/0699 issued on 13 June 2013 European Technical Assessment ETA-13/0699 of 14 June 2018 - Original version in German language General Part Technical Assessment Body issuing the European Technical Assessment: Trade name of the construction

More information

Cl/SfB 1 (4-) 1 RJ December 2018 (2) Cempanel. Cement Particle Board - Building board for external and internal applications

Cl/SfB 1 (4-) 1 RJ December 2018 (2) Cempanel. Cement Particle Board - Building board for external and internal applications Cl/SfB 1 (4-) 1 RJ7 1 1 December 2018 (2) Cempanel Cement Particle Board - Building board for external and internal applications Cempanel Class 0 cement particle board with excellent impact, fire and acoustic

More information

ISO INTERNATIONAL STANDARD. Wood-based panels Oriented strand board (OSB) Definitions, classification and specifications

ISO INTERNATIONAL STANDARD. Wood-based panels Oriented strand board (OSB) Definitions, classification and specifications INTERNATIONAL STANDARD ISO 16894 First edition 2009-11-15 Wood-based panels Oriented strand board (OSB) Definitions, classification and specifications Panneaux à base de bois Panneaux de lamelles minces,

More information

Q-MARK REGISTRATION SCHEDULE FOR STRUCTURAL PLYWOOD

Q-MARK REGISTRATION SCHEDULE FOR STRUCTURAL PLYWOOD Q-MARK REGISTRATION SCHEDULE FOR STRUCTURAL PLYWOOD Company : Huaian Arser Wood Co. Ltd Address : No 10 Yanhuang Road West Industrial Zone Lianshui Jiangsu China Establishment ID : 056/2698 Contents Page

More information

Exterior Wall Solutions Building Shell

Exterior Wall Solutions Building Shell A strong, water tight and thermally insulated building shell will ensure the buildings sustainability of usage over time. The Exterior Shell is the most important factor of protection to ensure that the

More information

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor 70, 100, 150, 200, 250 46 APPLICATION: Products:,,, 200, 250 insulation can be used over all types of precast suspended concrete floor systems including beam and block and hollow core plank. It is available in a range of grades

More information

Ask for FSC certified products. Ask for PEFC certified products.

Ask for FSC certified products. Ask for PEFC certified products. Ask for FSC certified products. Ask for PEFC certified products. ABOUT COMPANY Mission - provide solutions to enhance customers product value. Vision - to be a leader among wood based panel producers in

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

LIQUID APPLIED WATERPROOF ROOF COATINGS

LIQUID APPLIED WATERPROOF ROOF COATINGS J31 LIQUID APPLIED WATERPROOF ROOF COATINGS To be read with Preliminaries/General conditions. TYPE(S) OF COATING 120 WARM DECK ROOF COATING Substrate: Suitable structural roof deck (e.g. Plywood, OSB3,

More information

LIQUID APPLIED WATERPROOF ROOF COATINGS

LIQUID APPLIED WATERPROOF ROOF COATINGS J31 LIQUID APPLIED WATERPROOF ROOF COATINGS To be read with Preliminaries/General conditions. TYPE(S) OF COATING 120 WARM DECK ROOF COATING Substrate: Suitable structural roof deck (e.g. plywood, OSB3,

More information

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100

APPLICATION: Floor insulation precast suspended concrete floor. Products: Jabfloor Premium 70 and 100 38 APPLICATION: Products: 70 and 100 insulation can be used over all types of precast suspended concrete floor systems including beam and block and hollow core plank. It is available in a range of grades

More information

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

Xtratherm Thin-R Underfloor Board (XT/UF Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 3 Xtratherm Thin-R Underfloor Board (XT/UF Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Underfloor Board, as defined in NSAI Agrément Certificate

More information

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board

Technical Assessment Body issuing the ETA: Kiwa Nederland B.V. Sinh Board Member of Kiwa Nederland B.V. www.eota.eu Sir Winston Churchilllaan 273 NL-2288 EA Rijswijk Postbus 70 NL-2280 AB Rijswijk Tel.: +31 (0)88 998 44 00 Fax: +31 (0)88 998 44 20 E-mail: info@kiwa.nl European

More information

Evaluation Report CCMC R Murphy LVL

Evaluation Report CCMC R Murphy LVL Evaluation Report CCMC 13507-R Murphy LVL MasterFormat: 06 17 10 Evaluation issued: 2010-10-27 Re-evaluated: 2016-04-18 Revised: 2017-10-18 Re-evaluation due: 2016-10-27 1. Opinion It is the opinion of

More information

KINGSPAN FRAME SYSTEMS KINGSPAN STEEL FRAMING SYSTEM

KINGSPAN FRAME SYSTEMS KINGSPAN STEEL FRAMING SYSTEM Kingspan Steel Building Solutions Manor Works Pleck Road Walsall WS2 9ES Tel: 01944712000 Fax: 01922644460 e-mail: enquiries@kingspansbs.com website: www.kingspanpanels.co.uk/kip/steel-building-solutions

More information

LP OSB Sheathing & Structural 1 Sheathing

LP OSB Sheathing & Structural 1 Sheathing Rated OSB Sheathing Roof Panels Span Ratings Max. Live Load Thickness Span Rating for Roofs (lbs)** 3/8" 24/0 30 7/16" 24/16 40 15/32" 32/16 70 1/2" 32/16 70 19/32" 40/20 130 23/32" 48/24 175 1-1/8" 48

More information

European Technical Assessment. ETA-18/0041 of Member of. General part

European Technical Assessment. ETA-18/0041 of Member of. General part INSTITU Schenkenstrasse 4 T +43 1 533 65 50 1010 Vienna Ι Austria F +43 1 533 64 23 www.oib.or.at Ι mail@oib.or.at Designated according to Article 29 of Regulation (EU) No 305/2011 Member of www.eota.eu

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 TYVEK SD2 AIR LEAKAGE BARRIER/VAPOUR CONTROL LAYER

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 TYVEK SD2 AIR LEAKAGE BARRIER/VAPOUR CONTROL LAYER DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

Jabfloor 70, 100, 150, 200, 250

Jabfloor 70, 100, 150, 200, 250 TECHNICAL DATA SHEET FLOOR INSULATION OVER SLAB WITH CHIPBOARD FINISH Jabfloor 70, 100, 150, 200, 250 Floor insulation over slab with chipboard finish Jabfloor is a closed cell expanded polystyrene (EPS)

More information

STRANDFLOOR H3.1 FLOORING. Product. Scope. Building Regulations. Appraisal No. 677 [2016]

STRANDFLOOR H3.1 FLOORING. Product. Scope. Building Regulations. Appraisal No. 677 [2016] STRANDFLOOR H3.1 FLOORING This Appraisal replaces BRANZ Appraisal No. 677 (2010) Amended 27 April 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Laminex New Zealand

More information

GA APPLICATION OF GYPSUM SHEATHING

GA APPLICATION OF GYPSUM SHEATHING 1. Scope 1.1 This specification describes the minimum requirements for, and the methods of handling, storage, and application of, gypsum sheathing for use as a substrate for exterior claddings. 1.1.1 Exterior

More information

Non- Combustible Sheathing Board for Steel Frame applications

Non- Combustible Sheathing Board for Steel Frame applications Non- Combustible Sheathing Board for Steel Frame applications BDA Expert Centre BDA Agrément BAW 18-085/01/A Non-Combustible Sheathing Board For Steel Frame applications. Features and benefits of Versaliner

More information

European Technical Assessment. ETA-18/0083 of Member of. General part

European Technical Assessment. ETA-18/0083 of Member of. General part INSTITU Schenkenstrasse 4 T +43 1 533 65 50 1010 Vienna Ι Austria F +43 1 533 64 23 www.oib.or.at Ι mail@oib.or.at Designated according to Article 29 of Regulation (EU) No 305/2011 Member of www.eota.eu

More information

SECTION Fiber Reinforced Stucco 1

SECTION Fiber Reinforced Stucco 1 CSI SECTION 09200 FIBER REINFORCED STUCCO PART 1 GENERAL 1.01 SUMMARY A. Section Description: Provided lath and plaster where shown on the Drawings, as specified herein, and as needed for complete and

More information

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017 ECOPLY RIGID AIR Amended 21 August 2017 BRANZ Appraisals Technical Assessments of products for building and construction. Carter Holt Harvey Plywood Ltd Private Bag 92-106 Auckland Tel: 0800 326 759 Fax:

More information

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 DUPONT AIRGUARD CONTROL AIR LEAKAGE BARRIER/ VAPOUR CONTROL LAYER

TYVEK ROOF LINING SYSTEMS PRODUCT SHEET 3 DUPONT AIRGUARD CONTROL AIR LEAKAGE BARRIER/ VAPOUR CONTROL LAYER DuPont de Nemours (Luxembourg) S.à r.l. Rue General Patton L-2984 Luxembourg Tel: 01275 879770 Fax: 01275 879773 e-mail: tyvek.construction@lux.dupont.com website: www.tyvekhome.com Agrément Certificate

More information

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications ANSI/APA PRS-610.1 Standard for Performance-Rated Structural Insulated Panels in Wall Applications 2008 APA - The Engineered Wood Association Draft 2 January 2008 Copyright 2008 by APA 7011 South 19th

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10 CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES 283 Chapter 10 FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 10.1 PLASTERWORK Workmanship i. All workmanship must be within the tolerances

More information

The Exsulite -Kooltherm Thermal Façade System. BCA 2016 Certificate Holder:

The Exsulite -Kooltherm Thermal Façade System. BCA 2016 Certificate Holder: Certification Body: THIS TO CERTIFY THAT Certificate number: CM40082 ABN: 80 111 217 568 JAS-ANZ Accreditation No. Z4450210AK PO Box 7144, Sippy Downs Qld 4556 +61 (07) 5445 2199 www.certmark.org Type

More information

SPE138_Overview_brochure.qxd 27/4/06 16:27 Page 7 FSC Supplier

SPE138_Overview_brochure.qxd 27/4/06 16:27 Page 7 FSC Supplier FSC Supplier smart thinking... If you want to build smart, you ve got to think smart. To find better quality and better value, you ve got to look beyond the obvious. That s why the smart money goes on

More information

roofing ROOFING Design of the base ROOFING DETAILS

roofing ROOFING Design of the base ROOFING DETAILS DETAILS The general arrangement details and the principles to be followed at skirtings, upstands, abutments, verges, gutters and expansion joints are as details illustrated. SELECTION PARAMETERS It is

More information

CertMark Australasia CodeMark Assessment Brief' THE OZONE PANEL BUILDING SYSTEM. For

CertMark Australasia CodeMark Assessment Brief' THE OZONE PANEL BUILDING SYSTEM. For CertMark Australasia CodeMark Assessment Brief' For THE OZONE PANEL BUILDING SYSTEM PURPOSE Ozone Panels are load bearing precast panels made up of two facades of OSB3 composite sourced from organically

More information

Evaluation Report CCMC R Fiberon Solid Decking- Horizon, Horizon Symmetry, Sanctuary, and Protect Advantage

Evaluation Report CCMC R Fiberon Solid Decking- Horizon, Horizon Symmetry, Sanctuary, and Protect Advantage Evaluation Report CCMC 13500-R Fiberon Solid Decking- Horizon, Horizon Symmetry, Sanctuary, and Protect Advantage MASTERFORMAT: 06 73 14.01 Issued: 2012-07-31 Re-evaluated: 2015-09-16 Revised: 2017-09-06

More information

LOW-E FOIL INSULATION FOR PITCHED ROOFS, DRY LININGS AND FLOORS LOW-E FOIL INSULATION FOR USE IN PITCHED ROOF APPLICATIONS

LOW-E FOIL INSULATION FOR PITCHED ROOFS, DRY LININGS AND FLOORS LOW-E FOIL INSULATION FOR USE IN PITCHED ROOF APPLICATIONS Low-E UK Ltd Unit 48 Weaver Industrial Estate Blackburn Street Liverpool Merseyside L19 8JA Tel: 0151 494 9994 Fax: 0560 310 7699 e-mail: info@low-e.co.uk website: www.low-e.co.uk APPROVAL INSPECTION TESTING

More information

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES CONTENTS 10.1 PLASTERWORK 10.2 2 ND AND 3 RD FIX FINISHES FUNCTIONAL REQUIREMENT 10.1 Plasterwork Workmanship Design Technical Manual TS-011-09-010412 i. All workmanship must be within defined tolerances

More information

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo

SINTEF Building and Infrastructure confirms that. Separating floors with Hunton Silencio 36 / Hunton Silencio Thermo SINTEF Certification No. 2330 Issued t: 18.02.2002 Revised: 17.06.2013 Valid until: 01.07.2018 Page: 1 of 5 SINTEF Building and Infrastructure confirms that Separating floors with Hunton Silencio 36 /

More information

12/12/2017 CMA-ER30204

12/12/2017 CMA-ER30204 CMI EVALUATION REPORT CMI-ER30204 MASONS PLASTERBRICK LTD UNI FLEXIBLE AIR BARRIER REPORT HOLDER MASONS Plastabrick Ltd 9B Parkhead Place Albany 0632, Auckland New Zealand Ph: +64 9 414 7551 W: www.mpb.co.nz

More information

KINGSPAN THERMAROOF TR21

KINGSPAN THERMAROOF TR21 CI/SfB Kingspan Insulation Limited Pembridge Leominster Herefordshire HR6 9LA Tel: 0870 8508555 Fax: 0870 8508666 e-mail: info.uk@insulation.kingspan.com website: www.insulation.kingspan.com (47) Rn Agrément

More information

Jabfloor 70, 100, 150, 200, 250

Jabfloor 70, 100, 150, 200, 250 Jabfloor 70, 100, 150, 200, 250 Floor insulation over slab with chipboard finish Jabfloor is a closed cell expanded polystyrene (EPS) insulation board for use in all floor constructions. A range of compressive

More information

ETA-11/0466 of 21/02/2018. European Technical Assessment. Member of. Designated according to Article 29 of Regulation (EU) No 305/

ETA-11/0466 of 21/02/2018. European Technical Assessment. Member of. Designated according to Article 29 of Regulation (EU) No 305/ Page 1 of European Technical Assessment ETA-11/0466 issued on 1 February 018 British Board of Agrément Bucknalls Lane Watford Herts WD5 9BA Tel: +44 (0) 193 6650 e-mail: clientservices@bbacerts.co.uk website:

More information

IWS FAST BOARD. Non-combustible sheathing board. Technical Guide. built in. Fire protection. excellent Acoustics. integrated Structural engineering

IWS FAST BOARD. Non-combustible sheathing board. Technical Guide. built in. Fire protection. excellent Acoustics. integrated Structural engineering IWS FAST built in FAST BOARD Non-combustible sheathing board 0-10 -20 Fire protection excellent Acoustics integrated Structural engineering optimal Thermal performance Technical Guide IWS-FAST Board is

More information

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice 1222 Moonshine Rd, RD1, Porirua 5381 Private Bag 50 908 Porirua 5240, New Zealand Tel: 04 237 1170 branz.co.nz Important Notice Since the issue of this Appraisal, a revised version of the Approved Document

More information

European Technical Approval ETA-06/0238

European Technical Approval ETA-06/0238 British Board of Agrément P O Box 195 Bucknalls Lane Garston, Watford Herts WD25 9BA Tel: + 44 (0)1923 665300 Fax: + 44 (0)1923 665301 e-mail: mail@bba.star.co.uk Authorised and notified according to Article

More information

HEMSEC SIPS SIP LOADBEARING WALL AND ROOF PANELS Système pour constructions Bausystem. Regulations

HEMSEC SIPS SIP LOADBEARING WALL AND ROOF PANELS Système pour constructions Bausystem. Regulations Hemsec Sips Ltd Stoney Lane Rainhill Prescot Merseyside L35 9LL Tel: 0151-426 7171 Fax: 0151-493 1331 e-mail: sales@hemsec.com website: www.hemsecsips.com CI/SfB 81 Rj7 Agrément Certificate No 06/4374

More information

Metal Web Floor System

Metal Web Floor System Metal Web Floor System Contents Contents Introduction and benefits 3 easi-joist definitions 4 easi-joist webs 5-6 Mechanical services 7 Loading and design 8 Floor stiffness 9 Internal non-loadbearing wall

More information

Jabfloor High Performance (HP) 70 and 100

Jabfloor High Performance (HP) 70 and 100 Jabfloor High Performance (HP) 70 and 100 Floor insulation over precast concrete suspended floor Jabfloor HP is a closed cell expanded polystyrene (EPS) insulation board for use in all floor constructions.

More information

BUILDBASE SUPPLIED BY IKO BREATHER MEMBRANE FOR USE IN TIMBER FRAME CONSTRUCTIONS

BUILDBASE SUPPLIED BY IKO BREATHER MEMBRANE FOR USE IN TIMBER FRAME CONSTRUCTIONS IKO PLC Appley Lane North Appley Bridge Wigan Lancashire WN6 9AB Tel: 01257 255771 Fax: 01257 252514 Agrément Certificate e-mail: technical.uk@ikogroup.com 15/5190 website: www.ikogroup.co.uk Product Sheet

More information

European Technical Assessment ETA-14/0354 of

European Technical Assessment ETA-14/0354 of European Technical Assessment ETA-14/0354 of 20.02.2015 GENERAL PART Technical Assessment Body issuing the European Technical Assessment Trade name of the construction product Product family to which the

More information

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures. SECTION 06 12 00 STRUCTURAL INSULATED PANELS ------------------------------------------------------------------------------------------------------------ PART 1- GENERAL ----------------------------- 1.1

More information

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures.

SECTION A. ACSE 7 Minimum Loads for Buildings and other Structures. SECTION 06 12 00 STRUCTURAL INSULATED PANELS ------------------------------------------------------------------------------------------------------------ PART 1- GENERAL ----------------------------- 1.1

More information