Bore 15 and 20 Threaded male BSP 0 C + 30 C Max Pressure : 16 Bars Specifications : Single jet Rotating dial Super dry Magnetic transmission
|
|
- Todd Anderson
- 6 years ago
- Views:
Transcription
1 Size : Ends : Min Temperature : Max Temperature : Bore 15 and 20 Threaded male BSP 0 C + 30 C Max Pressure : 16 Bars Specifications : Single jet Rotating dial Super dry Magnetic transmission Materials : Brass body Page 1 sur 7
2 SPECIFICATIONS : Single jet MID R100 for horizontal position and horizontal dial (respect the flow direction indicated by the arrow ) MID R50 for vertical position or horizontal position with vertical dial (respect the flow direction indicated by the arrow ) Rotating dry dial Magnetic movement Direct reading on 8 numerical rolls With 45 reading Brass body USE : Water distribution Min and max temperature Ts : 0 C to 30 C Max pressure Ps : 16 bars HEAD LOSS : Flow ( m3/h ) TYPICAL ERROR CURVE : Error in % Q1 : Min. flow Q2 : Transitional flow Q3 : Nominal flow Q4 : Max. flow Page 2 sur 7
3 RANGE : Cold water Ref.1704 bore 15 and 20 MATERIALS : Item Designation 1 Antifraud capsule 2 Gasket anticondense 3 Totalising mechanism 4 Antimagnetic ring 5 Sealing ring 6 Sealing plate 7 Turbine with shappire 8 Tungsten pivot 9 Holding gasket 10 Brass body 11 Strainer Page 3 sur 7
4 ACCESSORIES : Free nut water meter union with hole for filling on nut Male BSP o DN 15 F3/4"- M1/2" Ref o DN 15 F3/4"- M3/4" Ref o DN 20 F1" M3/4" Ref Plastic antifraud seal o DN 15 Ref o DN 20 Ref PVC pipe Male BSP ( waiting for water meter ) o DN 15, 110 mm long Ref o DN 20, 130 mm long Ref Brass pipe Male BSP ( waiting for water meter ) o DN 15, 110 mm long Ref Brass water meter stand o DN 15, 110 mm long Ref Page 4 sur 7
5 SIZE ( in mm ) : Ref. Bore G 3/4" 1 L Ø B H h Weight (Kg) Page 5 sur 7
6 TECHNICAL FEATURES ( according to MID ) : DN Max flow rate Q4 max ( m3/h) Nominal flow rate Q3 ( m3/h ) Min flow rate class MID R=100 Q1 with ± 5% error ( L/h ) Min flow rate class MID R=50 Q1 with ± 5% error ( L/h ) Transitional flow rate Class MID R=100 Q2 with ± 2% error ( L/h ) Transitional flow rate Class MID R=50 Q2 with ± 2% error ( L/h ) Min reading ( L ) Max reading ( m3 ) STANDARDS : Fabrication according to ISO 9001 : 2008 ICIM and IQNET DIRECTIVE 97/23/CE : Products excluded from directive ( article 1, 3.2 ) Approval certificate MID according to directive 2004/22/CE MID annex B Approval certificate Polish PZH French water agreement : A.C.S. N 11 ACC LY 067 Approval food certificate TIFQ DM 174/2004 Threaded male BSP cylindrical according to ISO ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 6 sur 7
7 INSTALLATION INSTRUCTIONS OF WATER METER BEFORE INSTALLATION : Pipe-line must be cleaned and free from residual of weldings,rubbish,shaving and every kind of extraneous materials. Pipe-line must be perfectly aligned and their support properly dimensioned so that there s no external constraint. It s recommended to use a water meter stand. When installing water meter on pipe-line, use fittings with flat span. To tighten the ends,use the appropriate tool. Use the right bolt tightening so that the ends won t be damaged. We suggest to place straight pipes before and after the water meter. Straight pipe must be length 5 times water meter DN. It s recommended to install a strainer before the water meter if there are some solid particles in the water. Install ball vales before and after the water meter, so to facilitate the possible water meter removal. We suggest to install no-return check valve after the water meter also. TESTS : During the tests under pressure, water meter must be removed to avoid overpressure risks. INSTALLATION Please make the water flow slowly to avoid water hammer. The meter pit shall be protected from flooding, rainwater and frost. INSTALLATION POSITIONS : The counter should be normally placed in an horizontal position The counter can be installed vertically with ascending flow or tilted without suffering any damage. It must be considered tough that in these cases the metering precision of the meter is going to be slightly altered. If necessary, the counter can be installed vertically with descending flow but the pipe should always be full of water in this case. NOTE: Never install the water meter in horizontal position with totalizer in upside down orientation. HORIZONTAL : Class MID R=100 Class MID R=50 ( Vertical dial assimilated to vertical position ) * : In vertical position, the metering precision of the meter is going to be slightly altered, and the pipe should always be full of water. VERTICAL* : Class MID R=50 Page 7 sur 7
Size : Ends : Min Temperature : Max Temperature : Matierials : Brass body
Size : Ends : Min Temperature : Max Temperature : Bore 15 and 20 Threaded male BSP 0 C ( for cold water type ) + 90 C ( for hot water type ) Max Pressure : 16 Bars Specifications : Single jet Rotating
More informationEN Size : Ends : Min Temperature : Max Temperature : Materials : Brass body
EN 1434 Size : Ends : Min Temperature : Max Temperature : Bore 15 and 20 Threaded male BSP + 5 C + 90 C Max Pressure : 16 Bars Specifications : Single jet For heating or cooling systems Magnetic-proof
More informationMaterials : Carbon steel or Stainless steel
Size : Ends : Min Temperature : Max Temperature : DN 8 to DN 50 Butt Welding, Socket welding or straight welding - 30 C in stainless steel and -20 C in carbon steel + 180 C Max Pressure : 138 Bars (Class
More informationCarbon steel or Stainless steel
MADE OF STAINLESS... Size : Ends : Min Temperature : Max Temperature : DN 8 to DN 50 Butt Welding, Socket welding or straight welding - 30 C in stainless steel and -20 C in carbon steel + 180 C Max Pressure
More informationMaterials : Carbon steel or Stainless steel MERXTRADE BV.
ADE B.V. Size : DN 1/4 to DN 2 Ends : Threaded female BSP, NPT or S.W. Min Temperature : - 30 C in S.S. and - 20 C in carbon steel Max Temperature : + 180 C Max Pressure : 138 Bars (Class 800) Specifications
More informationMaterials : Ductile iron body EN GJS 500-7
Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 1000 PN10/16 flanges - 10 C + 70 C with EPDM wedge Max Pressure : 16 Bars up to DN400, 10 bars over Specifications : Non rising
More informationSize : Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Ends : Min Temperature : Max Temperature : DN 50 to 600 Flanges R.F. PN10/16-10 C + 120 C Max Pressure : 16 Bars up to DN300 ( 10 bars over ) Specifications : Ductile iron disc All positions Low
More informationMaterials : Ductile iron body EN GJS 500-7
Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 600 Flanges PN10/16-10 C + 70 C Max Pressure : 16 Bars up to DN400, 10 bars over Specifications : Non rising stem Clockwise
More informationRef RESILIENT SEAT GATE VALVE ISO PN10-16 F4. Model/Ref:
Model/Ref: 180-181 - 182 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 600 ISO PN10/16 flanges - 10 C + 110 C with EPDM wedge Max Pressure : 16 Bars up to DN400,
More informationSize : Ends : Min Temperature : Max Temperature : Materials : Carbon steel
Size : Ends : Min Temperature : Max Temperature : DN 50 to DN 300 ( NPS 2 to 12 ) Flanges R.F. CLASS 150 (PN20) - 29 C + 425 C Max Pressure : 20 Bars Specifications : Rising rotating stem Bolted bonnet
More informationOVALNI ZASUN NP 10-16
procesna oprema OVALNI ZASUN NP 10-16 Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 1000 ISO PN10/16 flanges - 10 C + 110 C with EPDM wedge Max Pressure : 16 Bars up to DN400, 10 bars over
More informationWATER METERS MID ATLANTIS WATER METER.
WATER METERS Cer ti pot fica tion MID able wat er ATLANTIS WATER METER Hydrodynamic design The Hidroconta Atlantis water meter is based on the principle of single speed and sinlge jet. The water enters
More informationDorot Irrigation Meter
DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features
More informationStandpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants
Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants Flow rate Q n 2.5... 25. Weatherproof: designed for the tough conditions outdoors.
More informationNanning Guling(Goldland) W.P.E.Co. Addr: TianChiShan, 9 mid XianHu ave, Qingxiu dist, Nanning Guangxi,China
SINGLE JET DRY DIAL VANE WHEEL WATER METER MODEL: LXSC-13D~40D(COLD WATER);LXSC/R-13D~40D(HOT WATER) APPLICATION Measuring the volume of cold (hot) potable water passing through the pipeline. FEATURE Dry
More informationFlanged Water Meters (non-continuous flow)
Flanged Water Meters (non-continuous flow) Features MW-F Suitable for use with domestic water Pulsed output Low head loss Specification Product Codes Meter: Cold water: Fluid temp. range: Cold 0 to 30
More informationWP-SDC COPPER CAN REGISTER WOLTMAN WATER METER
WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial
More informationFROM METERING TO DATA MANAGEMENT WATER MEASUREMENT WS-NKP MULTI-JET WATER METER DN 15 DN 50
FROM METERING TO DATA MANAGEMENT WATER MULTI-JET WATER METER DN 15 DN 50 MID R 100 WS is a multi-jet dry-dial water meter designed for the measurement of cold water, normally adjusted to the assembly of
More informationMID R 800 AMR READY N E W MID R=800 ULTRIMIS W DATA APPLICATION WATER MEASUREMENT
SMART THINKING WATER ULTRIMIS W ULTRASONIC WATER METER DN15, DN20, D25 i DN32 MID R 800 AMR READY Ultrimis W a state-of-the-art ultrasonic water meter with the very latest patented design features including
More informationPOLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE
POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE The manufacturer guarantees only English text. Available on our web site: www.isomag.eu INDEX TECHNICAL DATA... 3 OVERALL FEATURES...
More informationSAPAG CHECK VALVES MODEL CLASAR
MODEL CLASAR CLASAR : the high dynamic response check valve FEATURES Closing time (dynamic response) is a fraction of a second Avoids pressure surges in the pipeline or minimizes them Suitable for high
More informationOPERATING INSTRUCTIONS Vane wheel water meters, single jet, dry type JS and wet type JM DN 15 40
OPERATING INSTRUCTIONS Vane wheel water meters, single jet, dry type JS and wet type JM DN 15 40 Congratulations on choosing our product. Below we present the operating instruction of vane wheel water
More informationTHE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES
THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:
More informationYARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES
Protecting pipeline components from damaging particles with minimal pressure drop FEATURES Body material - ASTM and/or ASME as permitted under boiler code and power piping code. Provides assurance of quality
More informationUnderground fire hydrants
Underground fire hydrants The company was founded in 987 by transforming the former CSA, which was a trading company dealing with pipes and valves for water networks, into a manufacturing company, through
More informationTOPAS PMG Hydraulic sensor hot water
TOPAS PMG Hydraulic sensor hot water O f c c b a b d a d 5657244 5657264 565139.4 The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Applications
More informationSuitable for use in a variety of fluid systems.
Suitable for use in a variety of fluid systems. General Description Pipeline Wye Strainers are in thousands of applications in chemical, petroleum, pulp and paper, and utilities, as well as numerous commercial
More informationCONA -Universal / CONA -Connector
CONA -Universal for quick assembly/disassembly on CONA -Connector or foreign system connectors CONA -Universal / CONA -Connector CONA B-Universal Bimetallic steam trap (BR 604) BR 604 Page CONA M-Universal
More informationGravity Fed Drip Irrigation Kit
Gravity Fed Drip Irrigation Kit Rivulis DK-G Gravity Fed Drip Irrigation Kit Rivulis DK-G Gravity Fed Drip Irrigation Kit The system offers many benefits: Higher yields and improved crop quality Precise
More informationTOPAS PMG / PMH Hydraulic sensor Hot water
TOPAS PMG / PMH Hydraulic sensor Hot water Applications The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Features Insensitive to turbulences
More informationElectromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12
Electromagnetic flowmeters dg: www.oryana.com.ar NEW Sensor MUT EL DSENG 1/ Sensor MUT EL MUT EL sensors represent the state of the art of EUROMAG INTERNATIONAL production for water cycle and process applications.
More informationInstallation Guide. KOHLER Toobi Pre-filter K-96024T-PF100-Q73/K-96024T-PF200-Q73
Installation Guide KOHLER Toobi Pre-filter K-96024T-PF100-Q7/K-96024T-PF200-Q7 KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD, ZHABEI DISTRICT, SHANGHAI, PRC POST CODE: 20046 ( ) 158 20046
More informationEC type-examination certificate UK/0126/0059 Revision 7
UK/0126/059 MI-001 EC type-examination certificate UK/0126/0059 Revision 7 issued by: The National Measurement and Regulation Office Notified Body Number 0126 In accordance with the requirements of the
More informationAVK Couplings and Adaptors
AVK SAUDI VALVES AVK Couplings and Adaptors Solutions for All Applications 2 A Comprehensive Range of Couplings and Adaptors Product quality The complete coupling range is manufactured by AVK in accordance
More informationOPERATING INSTRUCTIONS Vane wheel water meters, single jet, dry type JS and wet type JM DN 15 40
OPERATING INSTRUCTIONS Vane wheel water meters, single jet, dry type JS and wet type JM DN 15 40 Congratulations on choosing our product. Below we present the operating instruction of vane wheel water
More informationDIVISION 15- MECHANICAL Section Fire Pumps
DIVISION 15- MECHANICAL Section 15320 Fire Pumps 1.00 PART 1 -GENERAL 1.01 DESCRIPTION OF WORK: A. Provide pumps for fire suppression. 1.02 SECTION INCLUDES: A. Vertical Turbine Fire Pump RELATED DOCUMENTS:
More information0.75 " transparent hose w/ valve for head measurements fixed to screws 20 MIL PVC liner. 6" gate valve
0.75 " transparent hose w/ valve for head measurements fixed to screws 250x1000 RC beam 6" gate valve Foundation preparation in accordance with technical specifications and as approved by engineer 25 cm
More informationPanelGrip Dry Glaze Glass Railing System
Metric Version PanelGrip Dry Glaze Glass Railing System Patent Pending Nationwide supplier of trims, mouldings and components for the glass and mirror industry. Reduces Labor Costs up to 80% Reduces Freight
More informationM15 ISO Ball Valve DN¼" to DN2½"
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationMW-MJx Screwed Multi Jet Flow Sensors
Date of Issue: /0/0 Issue Number:. Page of 6 MW-MJx Screwed Multi Jet Flow Sensors Features: Reinforced bearings High measuring stability Compatible with MW-MD integrator Technical Overview The MW-MJ range
More informationBall Float Steam Trap UNA 45, UNA 46, UNA 46A PN 40/Class 300 DN 15, 20, 25, 40, 50, 65
Data Sheet 819345-02 Issue Date: 06/16 all Float Steam Trap UNA 45, UNA 46, UNA 46A PN 40/Class 300, 20, 25, 40, 50, 65 UNA 45 hl, UNA 46 hl, UNA 46A hl UNA 45 hl UNA 45 hl Description Float traps type
More informationTerrain HDPE. Product Guide
TAGIG1-PT JULY 2009 Terrain HDPE Product Guide Terrain HDPE BBA BRITISH BOARD OF AGRÉMENT CERTIFICATE No. 07/4479 A modern high density polyethylene system with many advantages over cast iron and other
More informationFPD170 orifice carrier assemblies Differential pressure primary flow element
Data sheet DS/FPD170 EN FPD170 orifice carrier assemblies Differential pressure primary flow element Simplified installation of orifice plates Measurement made easy Simplified installation tapping points
More informationCertificate of EC type-examination of a measuring instrument Number: UK/0126/0055 Revision 1
(UK/0126/0055) MI-001 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0055 Revision 1 issued by the Secretary of State
More informationTECHNICAL MANUAL. MODIX Rebar Coupler Safe and Flexible Rebar Coupling System
TECHNICAL MANUAL MODIX Rebar Coupler Safe and Flexible Rebar Coupling System Version: PEIKKO GROUP 01/2016 MODIX Rebar Couplers Safe and flexible rebar splicing system Reduces congestion of reinforcement
More informationTECHNICAL CATALOGUE CATALOGO TECNICO MANUAL VALVES FOR RADIATORS
TECHNICAL CATALOGUE CATALOGO TECNICO MANUAL VALVES FOR RADIATORS TEC ITAP SpA, founded in Lumezzane (Brescia) in 97, is currently one of the leading production companies in Italy of valves, fittings and
More informationØ mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGY OF SUCCESS ISO 9001
Ø 16 110 mm SYSTEM KAN-therm PP High quality for reasonable price TECHNOLOGY OF SUCCESS Contents 3 System KAN-therm PP The material... 94 Sanitary systems installation... 95 Pipes... 95 Thermal elongation...
More information4-Beam-Turbidity Meter ITM-4
1 Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Authorizations Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase separation
More informationPARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )
PARTS & ACCESSORIES: MODEL BTX & 0 Section 64 Page 64. Issue E FEATURES MODEL BTX DUPLEX (/4 TO 4 ) Dynamic sealing design for long life Easy-to-operate lever handle no gear box required Unique seat and
More informationPVC Stub Flanges & Backing Rings
PVC Stub Flanges & Backing Rings Australian Made for the pressure pipe market Quick Alignment No Pre-drilling of Holes Easier Installation Australian Made Manufactured to Class 18 Quality ISO 9001 Lic
More informationISI Marked Class-A & Class-B Water Meters as per IS: 779 / 1994 Conforming to ISO 4064 Standard for Cold Water Meters
Product Range ISI Marked Class-A & Class-B Water Meters as per IS: 779 / 1994 Conforming to ISO 4064 Standard for Cold Water Meters Electromagnetic flow meters for water & waste water applications IBR
More informationAVK 26 AVK UK Water Mains to Meter Offer & Price List 2017
AVK 26 AVK UK Water Mains to Meter Offer & Price List 2017 Technical introduction AVK is a new patented range of composite push fittings combining the safety and strength of a traditional mechanical fitting
More informationFoundation Specifications
Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas ulletin 37835A Revision L Introduction This document specifies typical foundation characteristics, designs,
More informationRegulating valves REG 6-65, REG-SS 15-40
MAKING MODERN LIVING POSSIBLE Technical brochure Regulating valves REG 6-65, REG-SS 15-40 REG are angle-way and straight-way regulating valves, which act as normal stop valves in closed position. The valves
More informationThe Viking Johnson range of MaxiFit products - High tolerance pipe couplings - MAXIFIT
Including Large Diameter MaxiFit The Viking Johnson range of MaxiFit products - High tolerance pipe couplings - MAXIFIT Overview MaxiFit High tolerance pipe couplings B A C The Viking Johnson range of
More informationK-FLEX SOLAR SYSTEM SOLAR SYSTEM
K-FLEX SOLAR SYSTEM SOLAR SYSTEM K-FLEX offers a line of products designed specifically for solar heating, renewable energy sources used to produce hot water using solar energy. The product range consists
More informationFoundation Specifications for 3.6-/3.7-Meter Earth Station Antennas
Installation Instructions Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas Bulletin 37835A Revision E Introduction This document specifies typical foundation characteristics, designs,
More informationClean Speed Controller with One-touch Fitting
Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG Series -FPG Series -FPQ P N Speed controllers for clean room use V S R Q -FPQ: (electroless nickel plated) and -FPG: are now available as
More informationPreparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders
GEP-6050 Rev. F 23777 Ref. I.D.: 8681 Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders WARNING USER SHOULD READ AND
More informationAPPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.
OPERATING LIMITS Flow rates up to : m /h Heads up to :, m Max. operating pressure : bar Max. loop temperature : +8 C Max. circulator temperature: C Max. ambient temperature : + C Water hardness (TH) :
More informationCONDUIT ACCESSORIES AND FIXINGS
CONDUIT ACCESSORIES AND FIXINGS L1 : EExd IIB CONNECTION FITTINGS B.. L2 : EExd IIC CONNECTION FITTINGS BMFA L3 : EExd IIC ELBOWS 90 ELF L4 : EExd IIC NIPPLES AND COUPLINGS NP - EM L5 : EExd IIC PLUGS
More informationMeter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection
More informationSAMSON LIQUID RING VACUUM PUMPS. 33 mbar absolute to 1013 mbar absolute. DATASHEET ME-SERIES DOC1005A
TRUCKS FOOD OFFSHORE FISH PROCESS DATASHEET ME-SERIES DOC1005A ME-SERIES Range: 33 mbar absolute to 1013 mbar absolute. Capacity: From 50 m3/h to 165 m3/h Index Page About SAMSON PUMPS...4 Materials...5
More information452 Series Magnetic Drive Positive Displacement Disc Meters Size 1
Size 1 Features APPLICATIONS: Measurement of cold water for residential and small commercial applications where water volumes are low, and low flow sensitivity is important. CONFORMANCE TO STANDARDS: Hersey
More informationCONTINUED ON FOLLOWING PAGE
Date Description of Change Pages / Sections Modified ID 08/05/17 Entire document - mgl PART 1 - INTRODUCTION 1.1 This standard refers to the following plumbing specialties. A. Drains, B. Hydrant and Hose
More information1 Are you spending too much to transport air? The total expense of distributing air from your compressors to its point of use involves more than just the cost of piping. It also includes labor-intensive
More informationCity of Port Moody. Water Meter Specifications
City of Port Moody Water Meter Specifications Engineering Division, Updated December 2015 City of Port Moody Water Meter Specifications 1. Preamble... 3 2. Definitions... 3 3. Services to be Metered...
More informationPN 40 DN 25-40, PN 25 DN 50-80, PN 16 DN Ball seal alternatives Stellite (KC) PTFE (TC) Tightness class ISO 5208, EN RATE D RATE A
Operation WAFER PATTERN V-PORT BALL VALVE stainless steel 5, 501 series C ont R o L Description Edition Högfors ball sector valve series 5 is specially designed for control applications of various media
More informationIron Check Valves & Y-Strainers Illustrated Index
Iron Check Valves & Y-Strainers Illustrated Index Iron Body Swing Check Valve Bronze Mounted or All Iron 125 lb. SWP 200 lb. CWP Iron Body Swing Check Valve Bronze Mounted 250 lb. SWP 500 lb. CWP Lead
More informationList of Acceptable Product Specifications CPDMS0018
List of Acceptable Product Specifications CPDMS0018 17 July 2018 Contents Foreword 3 Pipe and Fittings 4 Polyvinylchloride (PVC) 4 Ductile Iron (DI) 4 Mild Steel (MS) 5 Polyethylene (PE) 5 Polypropylene
More informationAUTOMATIC AIR VALVES For potable water
AUTOMATIC AIR VALVES For potable water Page N Air release valve Page N Air release valve avent Page N Air release valve DN 0 / DN 0, DN 150 / DN 00 Page N /1 Page N5 Combined air release valve Page N 5/1
More informationINDUSTRIAL THERMOMETERS
JJ SIKA thermometers for industry and marine sector JJ Special versions and accessories JJ SIKA thermometers for heating, air conditioning and ventilation (HVAC) INDUSTRIAL THERMOMETERS Contains products
More informationHAWLE-range of products
HAWLE-pRODucTS All OvER ThE world since 1948 HAWLE-range of products HAWLE subsidiaries HAWLE partners Illustrations, technical data, dimensions and weights are subject to alteration without notice. Edition
More informationTechnical data Housing material &URTHERôVERSIONSôONôREQUEST
Silencer Plastic version Sintered bronze with thread or plug connection Various construction Flat design for restricted space Stainless steel silencer Silencers are used to reduce the noise level of the
More informationCITY OF FARGO SPECIFICATIONS SEWER AND WATER SERVICE CONNECTIONS
SEWER AND WATER SERVICE CONNECTIONS PART 1 DESCRIPTION OF WORK The work to be done under this section of the Specifications and the accompanying plans consists of the furnishing of all labor, material,
More information1071 Cast Steel Globe Steam Stop Valve (Flanged)
1071 Cast Steel Globe Steam Stop Valve (Flanged) Flanged Ends to DIN 2545 PN 40. Straight Pattern, Outside Screw, Yoke Type, Rising Stem, Bolted Bonnet. Renewable 13% Cr. Stainless Steel (S.S 410) working
More information60Hz. Route range ZMR. mechanical sealed TMR. magnetical driven. centrifugal pumps in thermoplastic materials
6Hz Route range ZMR mechanical sealed TMR magnetical driven centrifugal pumps in thermoplastic materials 2 Route TMR - ZMR In this catalog Argal proposes the range of ROUTE pumps, inclusive of magnetical
More informationClean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10
Clean Gas Filter Series Cartridge Type/Disposable Type Disposable type C0 Disposable type B30 Cartridge type 0 20 30 H HW T U B K MG FF M MD MH ME MF ZFC LLB D Cartridge type B0 B20 295 SMC Clean Gas Filter
More informationTERMS OF REFERENCE. Supply and Delivery of Prefabricated Wind Noise Reduction Systems (WNRS) and Equipment Vaults
ANNEX B TERMS OF REFERENCE Supply and Delivery of Prefabricated Wind Noise Reduction Systems (WNRS) and Equipment Vaults 1. INTRODUCTION The Preparatory Commission for the Comprehensive Nuclear-Test-Ban
More informationThis specification, applies at any Vale locations indicated with approval on the cover page, with the following exceptions:
1/5 1.0 PURPOSE This specification describes the minimum requirements for cold potable water plumbing systems within buildings. 2.0 APPLICATION This specification, applies at any Vale locations indicated
More informationSeries AS-FPQ/AS-FPG. Speed Controller with for Clean Room. Speed controllers for clean room use
Speed Controller with for Clean Room Series AS-FPQ/AS-FPG Series AS-FPG Series AS-FPQ AS ASN Speed controllers for clean room use AQ ASV AK ASS AS-FPQ: (electroless nickel plated) and AS-FPG: Stainless
More informationEUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call
EUROPE S LARGEST SELECTION OF TEST & MEASUREME EQUIPME FOR HIRE INLEC.COM Nationwide Low Call 0333 6000 600 WHY BUY WHEN YOU CAN HIRE Introduction The N ixon range of turbine flowmeters offers high accuracy
More informationArms Group Drainage System. 1. Swivel Joint Type 2. Pivot Joint Type 3. Flexible Hose Type 4. Swing Master Joint Type 5. Floating Check Valve
Arms Group Drainage System 1. Swivel Joint Type 2. Pivot Joint Type 3. Flexible Hose Type 4. Swing Master Joint Type 5. Floating Check Valve Swivel Joint Type Model No. 1010 Sizes 3in through 8in Heavy
More informationh Installation Manual
h Installation Manual 1 General Information The installation of HOBAS GRP Pipes is subject to applicable standards and guidelines such as EN 1610 and ISO/ TS 10465-1. Correct installation always requires
More informationSITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview
Overview Design and operation The main components of the Tubux variable area meters are the glass variable-area flow tube with float, the fitting and the connection parts. The flow is displayed directly
More information1.2 REFERENCES.1 American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME)
Issued 2005/06/01 Section 15113 Valves Cast Steel: Gate, Globe, Check, Ball Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01355 Waste Management and Disposal 1.2 REFERENCES.1 American National
More informationAENOR Mark Specific Rules for polypropylene (PP) systems for hot and cold water installations
AENOR Mark Specific Rules for polypropylene (PP) systems for hot and cold water installations Note: This document is a translation of the Spanish document RP 01.16 rev 12 approved by the Plastics Technical
More informationSEMPELL HP PREHEATER PROTECTION VALVES TYPE AVS 4/5
Typical feed water heater isolation system FEATURES Body of forged steel Body in form piece to reduce a number of welds and fittings Body also available as a single block type thereby eliminating the nozzle
More informationis Central. Gas Water & Waste Water Energy Industrial Your One-Stop Source State-of-the art manufacturing
Experience is Central. Backed by more than 50 years of experience, Georg Fischer Central Plastics is the largest single source supplier for meter connections including products and technologies that prevent
More information.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)
Fitness Facility Addition Page 1 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 03300 - Cast-in-Place Concrete.2 Section 05121 - Structural Steel for Buildings.3 Section 05500 - Metal Fabrications 1.2 REFERENCES.1
More informationFloat valves Types SV 4, SV 5 and SV 6
Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia
More informationE 094 E 103 E 143 Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min
Return Filters E 9 E E Tank top mounting Connection up to G Nominal flow rate up to l/min Description Application In the return line circuits of hydraulic systems. Performance features Protection against
More informationPlastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases
Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or
More informationLMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request
More information4-Beam-Turbidity Meter ITM-4
SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-4 FOOD 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring
More information4-Beam-Turbidity Meter ITM-4
SENSORS FOR AND BIOPHARMA. Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase
More informationOPERATING INSTRUCTIONS Flange water meters DN
OPERATING INSTRUCTIONS Flange water meters DN 40 500 Congratulations on choosing our product. Below we present the operating instruction of water meters with flange connectors DN 40 300, manufactured by
More informationE 443 E 453 E 463 E 643. Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min e
R e t u r n F i l t e rs E 443 E 453 E 463 E 643 Tank top mounting Connection up to SAE 2 Nominal flow rate up to 550 l/min 20.50-4e D e s c r i p t i o n Application In the return line circuits of hydraulic
More informationDATA SHEET MS2500_EN-IT_DS006REV14
DATA SHEET MS 2500 INDEX TECHNICAL DATA 2 97/23/CE PED DIRECTIVE 3 OVERALL DIMENSIONS 4 SENSOR VERSIONS/JUNTION BOX 7 SEPARATE VERSION 8 INSTALLATION RECOMMENDATIONS 9 RECOMMENDED INSTALLATION PROCEDURE
More informationDATA SHEET MS2500_EN-IT_DS006REV17
DATA SHEET MS 2500 INDEX TECHNICAL DATA 2 97/23/CE PED DIRECTIVE 3 OVERALL DIMENSIONS 4 SENSOR VERSIONS/JUNTION BOX 7 SEPARATE VERSION 8 INSTALLATION RECOMMENDATIONS 9 RECOMMENDED INSTALLATION PROCEDURE
More information