The Microgeneration Certification Scheme (MCS) Richard Phillips BRE Global
|
|
- Conrad Smith
- 6 years ago
- Views:
Transcription
1 The Microgeneration Certification Scheme (MCS) Richard Phillips BRE Global
2 Benefits of Microgeneration Systems When correctly designed, manufactured and installed micro renewable systems can: Provide a useful proportion of a building s energy demand Help reduce CO 2 emissions Help achieve higher sustainability ratings (e.g. for BREEAM and CSH) Help satisfy planners and home owners expectations for sustainability Be good value for clients and taxpayers money Enhance the reputation of the industry Encourage uptake
3 Why MCS? Replacement needed for Clear Skies and PV schemes More robust Protect reputation of the industry UKAS accreditation Independent Protect consumers by providing robust criteria for: Quality of products Quality of installations Mitigate Risks
4 Risks Things can go wrong! Little knowledge amongst homeowners Poor performance can Increase running costs Cause discomfort Reduce, or even reverse, emissions savings Poor design and installation can: Be unsafe Reduce system performance Damage the building envelope Any of the above could turn a positive vision into a negative image
5 The Microgeneration Certification Scheme MCS Mark: MCS mark owned by Secretary of State (DECC) Mark licensed to Gemserv (MCS administrator) Sub licensed to Certification bodies Certification bodies issue mark to certificated companies
6 The Microgeneration Certification Scheme UKAS DECC Gemserv MCS Steering Group Technical Working groups etc Stakeholders: Industry Trade assoc.s Consumer groups Grant bodies DECC Certification bodies Scheme documents & standards etc UCAS Etc. etc. Certificated companies
7 The MCS Installer Scheme Certification of companies not individuals Scope Design, supply, installation, set to work, commissioning and handover of microgeneration systems Assessments conducted in two parts: Office Assessment MCS 001 Quality control Membership of an OFT approved consumer code of conduct (e.g. REAL) On-site Installation Assessment Technology specific installation standard (MIS 300X) Estimate of annual energy performance Certification is maintained through surveillance assessments (usually annually)
8 MCS Simply Explained Say what you do, Have written procedures do what you say, Follow your procedures prove it. Get MCS certification
9 Office Assessment Quality manual appropriate to the business Don t be intimidated! A small business probably doesn t need a complex quality manual (but a large one might) Feedback suggests a good quality manual improves the business Needs to be a controlled document Formal approval & sign-off = ownership Issue number and date Singing from the same hymn sheet
10 Office Assessment Assesses procedures for a number of activities including: Who is responsible for each activity Document control e.g. keeping up with changes in regulations and standards Customer contracts Very important Equipment and calibration Training and competence Written procedures ensure quality and consistency Full requirements are detailed in MCS001 Annex A, Table 1
11 On-site Assessment Technology specific installation standards Assessment of competence to install, not the installation itself Proof of knowledge and competence Needs to be a recent installation completed by the installer
12 The MCS Product Scheme Scheme covers: Solar Collectors (MCS 004) Solar Photovoltaic Modules (MCS 005) Micro and Small Wind Turbines (MCS 006) Heat Pumps (MCS 007) Biomass (MCS 008) Heat-led Micro-cogeneration Packages (MCS 014) Fuel Cells and Micro Hydro are in preparation Scope Not exceeding 50kW for electricity generators Not exceeding 45kW for heat
13 The MCS Product Scheme Product approval is generally in two parts: Technical evaluation Review of test reports Checks on the validity & completeness Establish build status of product(s) Factory production control Quality management system Consistency of manufacture of certificated products Annual surveillance Change control
14 Product Testing Acceptance criteria for test reports described in MCS 011 UKAS or equivalent test laboratories Testing must be in scope of accreditation Unaccredited independent test laboratories or manufacturers own testing facilities: Assessment of laboratory by certification body Confirmation of correct equipment, procedures & competence etc. at the time of testing Witness testing
15 Certification Contractors and products that meet the relevant requirements will be MCS certificated Listing on websites e.g. Eligibility for FITs etc. Use of MCS and Certification Body marks Differentiation
16 BRE Global Certification Scheme Current status: Scheme operating for: Solar Thermal Solar PV Micro-wind Heat pumps Biomass Micro-CHP Other standards under development Full UKAS accreditation achieved 410+ installers Certificated by BRE Global Business improvements 500+ products approved Further information:
17 Summary MCS in place to underpin and enhance confidence in the industry by setting minimum requirements for: Standard of installations Product performance Installer and product schemes established Annual energy calculations Consumer code of conduct Minimum performance requirements Initial assessment followed by surveillance A number of certification bodies now operating MCS Robustness of the schemes needs to be maintained
18 THANK YOU Richard Phillips BRE Global Bucknalls Lane Garston Watford WD25 9XX
19 Mark Group Project Case Studies Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
20 Solar Hot Water Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
21 Outline Brief 10 Nursing Homes All in need of refurbishment High hot water & heating requirement Concern about rising energy costs Mixed fuel types Gas & Electric Vulnerable customers / priority groups Budget constraints Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
22 Initial Scope Mark Group met the client to agree Aims of the project To identify key problem areas Order of priority Budget More added to scope because of LCBP potential funding Project risks/ Feasibility Communication to the Residents Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
23 Site Assessment Home Insulation Appropriate Wind Power Solar Roof/s Energy for Heat Panels Harvesting? Energy Advice
24 Home Insulation Wind Power Solar Access Energy? Heat Harvesting Energy Advice
25 Space in Plant Room for Water Storage? Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
26 Home Insulation Space Wind Power in Loft Solar for Pumps Energy Heat and Harvesting Pipes? Energy Advice
27 Safe Loft Access? Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
28 Solution Design Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
29 Solution Design Budget / Funding Heating Needs? Solar Water Heating Hot Water Needs Timescale Existing Systems Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
30 Pre-Installation Communication with Council Site Manager/s Residents Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
31 Installation Installation of: Pumps Cylinders Pipework Panels Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
32 Before During After
33 Results Post Install Funding from LCBP programme received in accordance with the offer Happy users who were involved all the way Happy client fuel usage reduction of ~30% Further 4 installs ordered and planned further LCBP funding offers approved Other properties at survey stage Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
34 Summary Mark Group provided client with: The best technology solution to meet their needs A full service from inception to completion Assistance with funding application A positive outcome Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
35 Solar Electricity Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
36 Outline Brief Modern Secondary School High electric usage and costs Concern about rising energy costs Budget constraints Educational opportunity Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
37 Initial Scope Mark Group met the Headmaster to agree Aims of the project To identify key risk areas Budget LCBP funding / Feed-in Tariff Power Purchase Agreement Project plan Communication to the Pupils and Staff Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
38 Site Assessment Appropriate Roof/s for Panels?
39 Access?
40 Plant Room Access?
41 Solution Design
42 Solution Design Budget / Funding Electrical Needs? Solar Photovoltaic System Education Needs Timescale Existing Systems
43 Pre-Installation Communication with Headmaster Staff Pupils Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
44 Installation Installation of: Brackets Framework Panels Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
45 Installation of: Inverters Isolators Meters Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
46 Before
47 During
48 After
49 Results Post Install Funding from LCBP/FIT received in accordance with the offer Happy Headmaster green electric supply of 35,000 kwh s Educated pupils / staff integrated lesson plans Other schools at survey / planning stages Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
50 Summary Mark Group provided client with: The best technology solution to meet their needs A full service from inception to completion Assistance with funding application A positive outcome Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
51 Thank You Questions and Answers Home Insulation Wind Power Solar Energy Heat Harvesting Energy Advice
The Microgeneration Certification Scheme (MCS) John Holden BRE Global
The Microgeneration Certification Scheme (MCS) John Holden BRE Global Drivers for the uptake of Microgeneration Technologies Greenness Meeting Targets 2016 zero carbon homes CO 2 emissions reduction Renewable
More informationCertification and the UK Microgeneration Scheme. Dr. John Holden BRE Certification Ltd
Certification and the UK Microgeneration Scheme Dr. John Holden BRE Certification Ltd What is certification? Independent third party confirmation that a product or service complies with a specific standard
More informationLow and Zero Carbon Technologies: OPPORTUNITIES AND THE MCS
MCS Low and Zero Carbon Technologies: OPPORTUNITIES AND THE MCS A guide for plumbers, heating engineers, electricians and other parties interested in installing renewable technologies on the MCS quality
More informationMCS Installer Scheme. Your guide to registration
MCS Installer Scheme Your guide to registration 2 MCS Installer Scheme Your guide to registration Take advantage of the growing opportunities available to install renewable technologies. Purpose of this
More informationFunding incentives for energy saving and micro-generation
Funding incentives for energy saving and micro-generation Alan Grant Outreach Officer Energy Saving Scotland advice centre Highlands and Islands 11 September 2010 Energy Efficiency in the Home 25% Loft
More informationMicrogeneration Installation Standard: MIS 3002
Microgeneration Installation Standard: MIS 3002 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK COMMISSIONING AND HANDOVER OF SOLAR PHOTOVOLTAIC (PV) MICROGENERATION
More informationMicrogeneration Installation Standard: MCS 001. MCS Contractor certification scheme requirements Issue 2.5
Microgeneration Installation Standard: MCS 001 MCS Contractor certification scheme requirements Issue 2.5 This Microgeneration Installation Standard is the property of Department of Energy and Climate
More informationMicrogeneration Installation Standard: MCS 023. Additional Requirements for MCS Installation Companies to become Green Deal Authorised Issue 1.
Microgeneration Installation Standard: MCS 023 Additional Requirements for MCS Installation Companies to become Green Deal Authorised Issue 1.0 This Microgeneration Installation Standard is the property
More informationMicrogeneration Installation Standard: MCS 001. MCS Contractor certification Scheme requirements Issue 3.0
Microgeneration Installation Standard: MCS 001 MCS Contractor certification Scheme requirements Issue 3.0 This Microgeneration Installation Standard is the property of Department of Energy and Climate
More informationHow to deliver a renewable energy project. Jemma Benson CO2Sense
How to deliver a renewable energy project Jemma Benson CO2Sense CO2Sense Helping businesses to prosper in the low carbon economy Support for regional renewable electricity: specialist support larger schemes
More informationBRE Global Accreditation Schemes for Energy Assessors. delivering quality, integrity and opportunity
BRE Global Accreditation Schemes for Energy Assessors delivering quality, integrity and opportunity Introducing delivering quality, integrity and opportunity a partnership approach At BRE Global we are
More informationRenewable energy in more detail
Renewable energy in more detail There is a difference between knowing the basics about the options available and having an in-depth understanding of the practicalities around the installation process.
More informationRenewable Energy - A technology overview and the new Feed in Tariffs. Jos Mister Energy Saving Trust
Renewable Energy - A technology overview and the new Feed in Tariffs Jos Mister Energy Saving Trust Overview Renewable Technology Overview Generating electricity Generating heat Feed in Tariffs Clean Energy
More informationlessons learned from community based microgeneration projects the impact of renewable energy capital grant schemes
lessons learned from community based microgeneration projects the impact of renewable energy capital grant schemes monika munzinger, Kiruthiga srinivasan Venkataramanan, steve pester, david forward and
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) SMITHY COTTAGE, SCOTTISH BORDERS, KELSO, TD5 8LZ Dwelling type: Detached house Date of assessment: 08 May 2014 Date of certificate: 22 May 2014 Total floor area: 103
More informationnpower Microgeneration Scheme Feed In Tariffs A Guide to the Clean Energy Cashback Scheme
npower Microgeneration Scheme Feed In Tariffs A Guide to the Clean Energy Cashback Scheme What s inside 3 Make money from the energy you generate An introduction to Feed In Tariffs 4-5 How it works Your
More informationBRE: Feed in tariff update Jonny Williams BRE Wales and South West. Part of the BRE Trust
BRE: Feed in tariff update Jonny Williams BRE Wales and South West Part of the BRE Trust Feed in Tariffs - Update The feed in tariff (FIT) scheme encourages the uptake of small scale low carbon technologies
More informationMicrogeneration Installation Standard: MIS 3007
Microgeneration Installation Standard: MIS 3007 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE DESIGN, SUPPLY, INSTALLATION, SET TO WORK, COMMISSIONING AND HANDOVER OF A HEATING SYSTEM CONTAINING A MICRO-COGENERATION
More informationAn Introduction to the Renewable Heat Incentive
An Introduction to the Renewable Heat Incentive Tim Saunders Energy Saving Trust March 2011 Renewable Heat Incentive Starting July 2011 Designed to provide financial support that encourages individuals,
More informationThe Installers Guide to Training & Accreditation
Training in association with The Installers Guide to Training & Accreditation We re making Renewable more do-able Welcome to a brief guide to Renewable Training and Accreditation from Plumb Center MCS
More informationMicrogeneration Scheme - Feed in Tariffs. Our Guide to joining npower s Feed in Tariff Scheme
Microgeneration Scheme - Feed in Tariffs Our Guide to joining npower s Feed in Tariff Scheme 02 Microgeneration scheme Contents 3 Feed In Tariffs - what do you need to know? 4 So how does it work? 6 Get
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) 14 NEW ORCHARDFIELD, EDINBURGH, EH6 5ET Dwelling type: Mid-terrace house Date of assessment: 09 October 2013 Date of certificate: 10 October 2013 Total floor area:
More informationRenewable Energy. from the ground up. A complete service from design to installation for. Architects Developers Self-builders
Renewable Energy from the ground up A complete service from design to installation for Architects Developers Self-builders Bringing Renewable Energy Know-How to your project EnergyMyWay Your Complete Renewable
More informationMicrogeneration Installation Standard: MIS 3007
Microgeneration Installation Standard: MIS 3007 REQUIREMENTS FOR MCS CONTRACTORS UNDERTAKING THE DESIGN, SUPPLY, INSTALLATION, SET TO WORK, COMMISSIONING AND HANDOVER OF A HEATING SYSTEM CONTAINING A MICRO-COGENERATION
More informationMicrogeneration Installation Standard: MIS 3003
Microgeneration Installation Standard: MIS 3003 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK COMMISSIONING AND HANDOVER OF MICRO AND SMALL WIND TURBINE SYSTEMS
More informationRenewable Heat Incentive (RHI) Opportunities for Social Landlords in the RHI
(RHI) Opportunities for Social Landlords in the RHI [Name] [Date] Three good reasons to choose renewable heat 1. Now every building will be able to get an incentive if it goes renewable the RHI is a reality
More informationTop actions you can take to save money and make your home more efficient. Recommended measures Indicative cost Typical savings over 3 years
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland Dwelling type: Mid-terrace house Date of assessment: 05 March 2013 Date of certificate: 26 June 2013 Total floor area:
More informationMicrogeneration Installation Standard MIS 3006
Microgeneration Installation Standard MIS 3006 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK COMMISSIONING AND HANDOVER OF MICRO-HYDROPOWER SYSTEMS Issue 2.0 This
More informationULLAPOOL COMMUNITY TRUST RENEWABLE HEAT FOR LOCHBROOM
ULLAPOOL COMMUNITY TRUST RENEWABLE HEAT FOR LOCHBROOM INFORMATION PACK Contents 1 Introduction... 2 2 Project Outline... 2 3 Ullapool Community Trust s Role... 2 4 How the Project works... 4 5 Renewable
More informationMicrogeneration Installation Standard: MIS 3002
Microgeneration Installation Standard: MIS 3002 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK COMMISSIONING AND HANDOVER OF SOLAR PHOTOVOLTAIC (PV) MICROGENERATION
More informationMicrogeneration Installation Standard MIS 3006
Microgeneration Installation Standard MIS 3006 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK COMMISSIONING AND HANDOVER OF MICRO-HYDROPOWER SYSTEMS Issue 1.1 This
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) Summerhill, Crannaig A Mhinister, Pulpit Hill, Oban, PA34 4LX Dwelling type: Detached house Date of assessment: 11 October 2013 Date of certificate: 12 October 2013
More informationSmall Wind - Ireland Ray Byrne. U.S. Small Wind Conference Minnesota 9 th -10 th April 2018
Small Wind - Ireland Ray Byrne U.S. Small Wind Conference Minnesota 9 th -10 th April 2018 1 Recent History of Small Wind Policy makers became interested in small wind in 2008 as global activity was increasing
More informationMCS: 014. Product Certification Scheme Requirements: Heat-led micro-cogeneration packages in dwellings. Issue 1.3
MCS: 014 Product Certification Scheme Requirements: Heat-led micro-cogeneration packages in dwellings Issue 1.3 This Microgeneration Installation Standard is the property of Department of Energy and Climate
More informationEstimated energy use, carbon dioxide (CO ) emissions and fuel costs of this home2
Energy Performance Certificate New House Dwelling type: Detached house Hatfield Date of assessment: 26 July 2011 LEOMINSTER Date of certificate: 26 July 2011 HR6 0SG Reference number: 2968-5029-6243-8389-7950
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
17065:2012 to provide product conformity certification Unit 4 Pioneer Way Pioneer Business Park Castleford WF10 5QU Contact: Mr Mark Rollins-Mann Tel: +44 (0)845 621111 Fax: +44 (0)845 621112 E-Mail: info@stroma.com
More informationRenewable & Low Carbon Technologies
Services and Utilities Renewable & Low Carbon Technologies An overview Recommended Reading BSRIA Illustrated Guide to Renewable Technologies. What do we mean by renewable technologies? Generating electricity
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland PICTOU, HILL ROAD, SHAPINSAY, ORKNEY, KW17 2DZ Dwelling type: Detached bungalow Date of assessment: 05 June 2018 Date
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland Dwelling type: Semi-detached bungalow Date of assessment: 14 January 2013 Date of certificate: 18 January 2013 Total
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 12, Newport Street Brewood STAFFORD ST19 9DT Dwelling type: Semi-detached bungalow Date of assessment: 04 May 2011 Date of certificate: 06 May 2011 Reference number: 0668-0052-6225-8369-4930
More informationBarriers preventing the deployment of Small Wind Systems and the Economic Advantages
Barriers preventing the deployment of Small Wind Systems and the Economic Advantages Simon Powell Marine South East Ltd Southampton, UK EU Sustainable Energy Week, Brussels 14 April 2011 Wind a free fuel
More informationRenewable Heat Incentive: proposals for a domestic scheme. Community Housing Cymru Group response
Renewable Heat Incentive: proposals for a domestic scheme Community Housing Cymru Group response 1. About Us The Community Housing Cymru Group (CHC Group) is the representative body for housing associations
More informationMicrogeneration Certification Scheme (MCS)
Microgeneration Certification Scheme (MCS) MCS Competency Guidance Version 1.0 Effective date: 01/05/2018 01/05/2018 MCS Competency Guidance v1.0 Page 1 of 9 Contents COMPETENCY CRITERIA... 3 DEMONSTRATION
More informationSMS RETROFIT & PARTNERSHIP DELIVERY FRAMEWORK. An Introduction for SHAP Members
SMS RETROFIT & PARTNERSHIP DELIVERY FRAMEWORK An Introduction for SHAP Members SUREFIRE RETROFIT PARTNERSHIP & DELIVERY FRAMEWORK The SMS Retrofit Partnership & Delivery Framework was competitively tendered
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland SNAB FARM, SOLWAYBANK, LOCKERBIE, DG11 3HP Dwelling type: Detached bungalow Date of assessment: 04 May 2017 Date of
More informationwww.cityplumbing.co.uk CONTENTS Introduction Case Study Government Incentives Path to Renewables Training Solar Thermal Heat Pumps Biomass Photovoltaic Hybrid / Underfloor Heating Total renewable energy
More informationGreen Deal: the story so far Tokyo Green Deal Seminar 24 February 2014
Green Deal: the story so far Tokyo Green Deal Seminar 24 February 2014 Alan Clifford Senior Policy Advisor Household Energy Efficiency Programme Overview Context and background How Green Deal works Development
More informationHeadline technologies and solutions. Matt Dickinson
Headline technologies and solutions Matt Dickinson Shift in DEC distribution from 2009-2050 Carbon Trust Report Non-domestic buildings responsible for 18% of total UK carbon emissions 35% CO 2 reduction
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) You can use this document to: 1 TOLL HOUSE NEUK, TRANENT, EH33 2QU Dwelling type: Detached house Date of assessment: 15 May 2013 Date of certificate: 16 May 2013 Total
More informationEnergy Performance Certificate
Energy Performance Certificate 6 Bruce Close Dwelling type: Mid-terrace House WISBECH Date of assessment: 16 May 011 PE13 QA Date of certificate: 13 July 011 Reference number: 8959-6335-8760-786-499 Type
More informationThe Renewable Heat Incentive
The Renewable Heat Incentive Heating RHI Expected Outcome Non-Domestic Ground Source Heat Pumps Air Source and Ground Source Heat Pumps Increased tariffs for Air and Ground Source RHI First Announcement
More informationMicrogeneration Certification Scheme (MCS)
Microgeneration Certification Scheme (MCS) MCS Competency Guidance Version 1.1 Effective date: 06/02/2019 06/02/2019 MCS Competency Guidance v1.1 Page 1 of 9 Contents COMPETENCY CRITERIA... 3 DEMONSTRATION
More informationInformation Guide: Microgeneration
Information Guide: Microgeneration Issue 21 Information Guide: Microgeneration This is an independent guide produced by Mitsubishi Electric to enhance the knowledge of its customers and provide a view
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 17, Rustic Avenue HALIFAX HX3 9QW Dwelling type: Mid-terrace house Date of assessment: 14 July 2011 Date of certificate: 14 July 2011 Reference number: 8369-6423-8610-4804-7996
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland Hole Of Clean Farm, Glencarse, Perth, PH2 7NS Dwelling type: Detached house Date of assessment: 07 November 2013 Date
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 41, Nightingale Way Apley TELFORD TF1 6DT Dwelling type: End-terrace house Date of assessment: 09 September 2011 Date of certificate: 12 September 2011 Reference number:
More informationMicrogeneration Installation Standard: MIS 3004
Microgeneration Installation Standard: MIS 3004 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK, COMMISSIONING AND HANDOVER OF SOLID BIOFUEL HEATING SYSTEMS Issue
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 6 PIPERSQUOY TERRACE, KIRKWALL, KW15 1EL Dwelling type: Mid-terrace bungalow Date of assessment: 21 November 2017 Date
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) 6A GRAMSDALE, GRAMSDALE, ISLE OF BENBECULA, HS7 5QP Dwelling type: Detached bungalow Date of assessment: 24 November 2012 Date of certificate: 26 November 2012 Total
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 15, Cambridge Road SOUTHAMPTON SO14 6RB Dwelling type: Semi-detached house Date of assessment: 01 June 2011 Date of certificate: 01 June 2011 Reference number: 8099-6226-8570-0739-0906
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 11, Kirby Road Glenfield LEICESTER LE3 8DF Dwelling type: Mid-terrace house Date of assessment: 04 August 2011 Date of certificate: 04 August 2011 Reference number: 8639-6028-8070-1954-5906
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 14 HIGH STREET, KIRKWALL, KW15 1AZ Dwelling type: Mid-terrace house Date of assessment: 05 June 2017 Date of certificate:
More informationMCS CONTRACTOR SCHEME YOUR GUIDE TO REGISTRATION
MCS CONTRACTOR SCHEME YOUR GUIDE TO REGISTRATION the power behind your business WELCOME THANK YOU FOR APPLYING TO BECOME PART OF NICEIC NICEIC is the market leading certification body for the MCS Contractor
More informationMicrogeneration Installation Standard: MIS 3004
Microgeneration Installation Standard: MIS 3004 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK, COMMISSIONING AND HANDOVER OF SOLID BIOFUEL HEATING SYSTEMS Issue
More informationUpcoming changes to the Domestic RHI
Upcoming changes to the Domestic RHI An overview of DECC s proposed amendments and their impact on scheme administration Harriet Arscott, Policy Manager Domestic RHI 09/12/14 The Department of Energy and
More informationEnergy Performance Certificate
Energy Performance Certificate 3, Kew Gardens Dwelling type: Mid-terrace house Priorslee Date of assessment: 1 July 011 TELFORD Date of certificate: 13 July 011 TF 9SY Reference number: 8169-643-8040-385-3996
More informationThe Green Deal Challenges and Opportunities Installation and supply chains
The Green Deal Challenges and Opportunities Installation and supply chains Nigel Banks MEng CEng MCIBSE Head of Energy & Sustainable Solutions Keepmoat Installation and supply chains [ 2 ] 1 Installation
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 29 HORDALAND, KIRKWALL, KW15 1UN Dwelling type: End-terrace bungalow Date of assessment: 10 January 2018 Date of certificate:
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) You can use this document to: 17 WILLOWTREE WAY, BANCHORY, AB31 5JQ Dwelling type: Detached house Date of assessment: 03 November 2012 Date of certificate: 04 November
More informationEconomic retrofitting of existing housing stock. existing housing Name stock
Title of Slide Title of Presentation Economic retrofitting of Economic Date, retrofitting Place of existing housing stock existing housing Name stock Position Cliff Willson Sustainability Energy Consultant
More informationEnergy efficiency of low voltage electrical installations
Energy efficiency of low voltage electrical installations One new area within international standards is the integration of requirements for energy efficiency into IEC 60364 (the international standard
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 145, Parsonage Road GRAYS RM20 4AY Dwelling type: Mid-terrace house Date of assessment: 28 March 2012 Date of certificate: 28 March 2012 Reference number: 8312-6827-9460-0628-3922
More informationA framework guide for Energy Efficiency Measures (N7)
A framework guide for Energy Efficiency Measures (N7) The new shape of procurement in Wales Introducing the WPA What makes the WPA different? The Welsh Procurement Alliance (WPA) is a new approach for
More informationHow the Renewable Heat Incentive can work for you
How the Renewable Heat Incentive can work for you Speaker Patrick Allcorn, Head of Domestic RHI, Department of Energy and Climate Change DECC. Contact Emma: easton@eauc.org.uk/ 01242 714321 www.eauc.org.uk
More informationSolar Thermal Explained... Barilla Solar. Presented by Karl Thorne
Solar Thermal Explained... Barilla Solar Presented by Karl Thorne COURSE OBJECTIVE to help you sell solar thermal by Understanding the technology Learning about some common applications and system layouts
More informationMost of us are into saving money these days, right?
Energy Saving Guide Most of us are into saving money these days, right? Surfing the web for the latest deals on everything from mortgages to TVs is a way of life. But have you ever considered the possibility
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 1 EAST END, FRONT ROAD, ST MARGARETS HOPE, ORKNEY, KW17 2SL Dwelling type: Detached house Date of assessment: 20 November
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland Dwelling type: Detached bungalow Date of assessment: 08 July 2014 Date of certificate: 09 July 2014 Total floor area:
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 25, Finchdene Grove WOLVERHAMPTON WV3 8BG Dwelling type: Detached bungalow Date of assessment: 18 January 2012 Date of certificate: 18 January 2012 Reference number: 9188-8009-6279-9642-8900
More informationEnergy Efficiency Criteria
MCS Company Scheme Criteria for: Energy Efficiency Criteria Current Criteria This document shows the Competence Criteria required to be met by a company undertaking the type of work detailed above. MCS
More informationRenewable Energy: Lessons from the community sustainable energy programme
Renewable Energy: Lessons from the community sustainable energy programme 9 February 2012 Part of the BRE Trust Welcome and introduction Matt Dickinson, BRE HOUSEKEEPING Fire alarm and evacuation procedure
More informationTop actions you can take to save money and make your home more efficient
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland Dwelling type: Detached bungalow Date of assessment: 26 March 2015 Date of certificate: 27 March 2015 Total floor area:
More informationMicrogeneration Installation Standard: MIS 3003
Microgeneration Installation Standard: MIS 3003 REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION, SET TO WORK COMMISSIONING AND HANDOVER OF MICRO AND SMALL WIND TURBINE SYSTEMS
More informationNorthumbria Research Link
Northumbria Research Link Walker, S. L. et al. (2005) 'Potential for microgeneration : study and analysis'. London: DTI, with Energy Saving Trust, Element Energy and E- Connect This report is available
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) 9 GOLF CRESCENT, ABOYNE, AB34 5GP Dwelling type: Semi-detached house Date of assessment: 24 October 2014 Date of certificate: 05 November 2014 Total floor area: 65
More informationEnergy Performance Certificate
Energy Performance Certificate 19 Clay Lane ROCHDALE Lancashire OL11 5SJ Dwelling type: Mid-terrace house Date of assessment: 21 June 2011 Date of certificate: 22 June 2011 Reference number: 2798-1005-6216-7259-1940
More information(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)
Energy Performance Certificate 244, Wharf Road Ealand SCUNTHORPE DN17 4JN Dwelling type: Detached house Date of assessment: 25 January 2012 Date of certificate: 25 January 2012 Reference number: 8672-6029-9200-6575-8922
More informationRenewable Energy Is it feasible in a distillery environment?
Renewable Energy Is it feasible in a distillery environment? Andrew Bright, ITPEnergised SWA Guide Published in 2012 Details on a range of technologies Information on subsidies Numerous examples of the
More informationName of approved organisation: RICS Protocol for Scotland
Energy Performance Certificate Address of dwelling and other details HILLSLEA SYMBISTER WHALSAY SHETLAND ZE2 9AL This dwelling's performance ratings Dwelling type: Detached house Name of approved organisation:
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) You can use this document to: 3 FERENEZE AVENUE, CLARKSTON, GLASGOW, G76 7RU Dwelling type: Semi-detached house Date of assessment: 02 July 2013 Date of certificate:
More informationWind uplift testing on the Click Fit PV mounting system to MCS012. Prepared for: Gary Bowden Cleaner Air Solutions UK Ltd.
Wind uplift testing on the Click Fit PV mounting system to MCS012 Prepared for: Gary Bowden Cleaner Air Solutions UK Ltd 4 th October 2010 Prepared by Name Dr P Blackmore Position Associate Director, Building
More informationMicrogeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION. to be used in conjunction with MIS 3001:
Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION to be used in conjunction with MIS 3001: REQUIREMENTS FOR CONTRACTORS UNDERTAKING THE SUPPLY, DESIGN, INSTALLATION,
More informationEnergy Performance Certificate (EPC)
Energy Performance Certificate (EPC) 13 KING HARALD KLOSS, KIRKWALL, KW15 1FT Dwelling type: Detached house Date of assessment: 01 April 2015 Date of certificate: 11 April 2015 Total floor area: 89 m 2
More informationEnergy Performance Certificate
Energy Performance Certificate 3 Shirley Road SIDCUP Kent DA15 7JW Dwelling type: Mid-terrace house Date of assessment: 03 February 2012 Date of certificate: 03 February 2012 Reference number: 0278-3062-6222-9152-3910
More informationTop actions you can take to save money and make your home more efficient. Recommended measures Indicative cost Typical savings over 3 years
You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 5 Mountain Lodge, Wanlockhead, Biggar, ML12 6UT Dwelling type: Semi-detached bungalow Date of assessment: 16 February
More informationBREEAM Professionals A Guide to Understanding their Roles
www.breeam.com BREEAM Professionals A Guide to Understanding their Roles GD121-0.0. 101241 BRE May 2018 2 Overview This document outlines the roles and responsibilities of the BREEAM Associate, Advisory
More informationRenewable and low carbon energy in new developments. Will Rivers The Energy Saving Trust
Renewable and low carbon energy in new developments Will Rivers The Energy Saving Trust Overview Technologies for use in domestic Code for Sustainable Homes / Merton % reduction from each technology Main
More informationSomali Renewable Energy 2016 Forum
Somali 2016 Forum February 20-23 Energy A Somali Challenge Progress through Education Ivan Jackson Technical Consultant Gollis University The Problem! Sub-Saharan Africa is starved for electricity Sub-Saharan
More information