Nichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka

Size: px
Start display at page:

Download "Nichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka"

Transcription

1 Last Amended on - Page 1 of 9 I. WATER 1. Drinking Water Colour 2120 B 1 to 100 Hazen Units ph 4500 H+, B 3 to 12 Electrical conductivity 2510 B 5 to 10,000 µs/cm Turbidity 2130 B 1 to 100 NTU Chloride Alkalinity 4500-Cl -, B 2320 B 10 to 2000 mg/l Residual Free Chlorine IS 3025 (Part-26):1986, (RA 2003) Kit Method 0.1 to 2 mg/l Total Hardness 2340 C 2 to 2500 mg/l Calcium Magnesium Dissolved Oxygen 3500 Ca, B 3500-Mg, B 4500-O, C 0.1 to 8 mg/l

2 Last Amended on - Page 2 of 9 Drinking Water Acidity 2310B 1 to 500 mg/l Boron Iron Chromium Hexavalent 4500-B, B 3500-Fe, B 3500-Cr, B 0.1 to 5 mg/l 0.01 to 2 mg/l 0.02 to 1 mg/l Sulphate IS 3025 (Part -24)-1986, (RA 2003) Turbidity Method 4 to 1000 mg/l Phospharus Fluoride Nitrate Nitrogen 4500-P, D 4500-F -, D IS 3025 (Part-34)-1988, (RA 2003) Chromotropic Acid Method 0.1 to 50 mg/l 0.1 to 5 mg/l 0.1 to 50 mg/l Total Dissolved Solids 2540 C 10 to 7000 mg/l Potassium Sodium 3500-K, B 3500-Na, B

3 Last Amended on - Page 3 of 9 2. Waste Water ph 4500 H+, B 3 to 12 Electrical conductivity 2510 B 5 to µs/cm Chloride Alkalinity 4500-Cl -, B 2320 B 10 to 2000 mg/l Total Hardness 2340 C 2 to 2500 mg/l Calcium Magnesium Chemical Oxygen Demand (COD) Biological Oxygen Demand (BOD), 3 days, 27 0 C Total kjeldhal Nitrogen Boron 3500 Ca, B 3500-Mg, B 5220 B 5210 B 4500-N org, B 4500-B, B 4 to mg/l 2 to mg/l 1 to 2000 mg/l 0.1 to 5 mg/l

4 Last Amended on - Page 4 of 9 Waste Water Iron 3500-Fe, B Sulphate IS 3025 (Part -24 )-1986, (RA 2003) Turbidity Method 0.01 to 2 mg/l 4 to 1000 mg/l Total Dissolved Solids 2540 C 10 to mg/l Phospharus 4500-P, D 0.1 to 50 mg/l Total Suspended Solids 2540 D 10 to mg/l Total Solids 2540 B 10 to mg/l Total Settable Solids 2540 F 10 to mg/l Fixed Solids 2540 E 10 to mg/l Volatile Solids 2540 E 10 to mg/l Oil & Grease IS 3025 (Part-39)-1991, (RA 2003) 10 to 1000 mg/l Residual Sodium Carbonate (RSC) NTLR/SOP/36, Issue No:01, Issue date:30/09/ to +5 Sodium absorption Ratio (SAR) NTLR/SOP/38, Issue No:01, Issue date:30/09/ to 40

5 Last Amended on - Page 5 of 9 Waste Water % Sodium IS 3025 (Part-45)-1993, RA to 100 Chromium Hexavalent Potassium Sodium Ammonical Nitrogen Organic Nitrogen II. BUILDING MATERIALS 3500-Cr, B 3500-K, B 3500-Na, B 4500-NH 3, B, C 4500-NH 3, B, C 0.02 to 1 mg/l 1 to 1500 mg/l 1 to 1500 mg/l 1. Soil ph NTLR/SOP/58, Issue No: 01, Page No to 8.5

6 Last Amended on - Page 6 of 9 Soil Electrical Conductivity NTLR/SOP/59, Issue No:01, Page No to 1 ms/cm Organic carbon Moisture Content Mineralizable Nitrogen NTLR/SOP/60, Issue No:01, Page No-83 NTLR/SOP/61, Issue No:01, Page No-76 NTLR/SOP/62, Issue No:01, Page No to 10% 0.5 to 18% 14 to 1500 kg/ha

7 Last Amended on - Page 7 of 9 Soil Available Phosphorus NTLR/SOP/63, Issue No:01, Page No to 500 kg/ha Available Potassium Exchangeable Calcium Exchangeable Magnesium NTLR/SOP/64, Issue No:01, Page No-99 NTLR/SOP/65, Issue No:01, Page No-103 NTLR/SOP/66, Issue No:01, Page No to 1500 kg/ha 1 to 2000 me/100 g Soil 1 to 1000 me/100 g Soil

8 Last Amended on - Page 8 of 9 Soil Available Sulphur NTLR/SOP/67, Issue No:01, Page No to 1000 mg/kg III. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring Oxides of Nitrogen IS 5182 (Part 6) : to 100 µg/m³ Respirable Suspended Particulate Matter (PM 10 ), Cyclonic Flow Technique IS 5182 (Part 23) : to 700 µg/m³ Particulate matter (PM 2.5 ) NTLR/SOP/41, Issue No: 01, Issue date: 30/09/ to 100 µg/m³ Sulphur Dioxide IS 5182 (Part 2) : to 100 µg/m³ 2. Stack Emission Monitoring Flow Rate IS (Part 3) : to 2800 m³/hr Particulate matter/ Dust Particulate Emissions IS (Part 1): 1985, (RA 2003) 5 to 1000 mg/nm³ Oxides of Nitrogen IS (Part 7): to 400 mg/nm³ Sulphur Dioxide IS (Part 2): 1985, (RA 2003) 3 to 200 mg/nm 3

9 Last Amended on - Page 9 of 9 IV. FOODS & AGRICULTURAL PRODUCTS 1. Spices (Chilli Powder, Turmeric Powder) Moisture IS , (RA 2009) 2.5% to 20% Total ash IS , (RA 2009) 0.5% to 10% Acid insoluble ash IS , (RA 2009) 0.5% to 3% Non volatile ether extract IS , (RA 2009) 0.5% to 20% Crude fibre IS , (RA 2009) 1% to 30% Lead chromate IS , (RA 2009) Present or Absent -X-X-X-X-X-X-X-X-X-X-X-X-X-X-

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m

More information

Prakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat

Prakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat Prakruti Environmental Engineers (Environmental ), Last Amended on - Page 1 of 7 I. WATER 1. Water (Ground Water/ Surface Water/ Drinking Water/ Treated Water) ph APHA 4500-H + B, Temperature APHA 2550

More information

Discipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9

Discipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9 Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 %

More information

Discipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5

Discipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5 Last Amended on - Page 1 of 5 AT LABORATORY I. WATER 1. Drinking Water, Colour IS 3025 (Part 4): 1983 (RA 2002) Spectrometer method 2120C Odour IS 3025 (Part 5): 1983 (RA 2002) 2 Hazen units to 500 Hazen

More information

Discipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on

Discipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on Last Amended on 18.01.2016 Page 1 of 8 I. WATER 1. Potable, Domestic and Bore-well Water ph IS 3025 (Part 11): 1983 Electrometric Method Colour IS 3025 (Part 4): 1983 Specific Conductance IS 3025 (Part

More information

ENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka

ENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka Certificate Number TC-6325 Page 1 of 5 Range ing / CHEMICAL TESTING I. WATER 1. Surface Water, Ground Water, Industrial Water, Drinking Water, Irrigation Water, Water From Purifiers & Swimming Pool Water

More information

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal Last Amended on - Page 1 of 16 I. WATER 1. Drinking Water ph IS 3025 (Part 2): 2004, Colour APHA (22 nd Edition) 2120 B: Turbidity (NTU) IS 3025 (Part 10): 1984 Residual, Free Chlorine IS 3025 Part 26/1986

More information

Winmet Technologies Private Limited, Plot No. E-65, Site-IV, UPSIDC, Greater Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Winmet Technologies Private Limited, Plot No. E-65, Site-IV, UPSIDC, Greater Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date Last Amended on - Page 1 of 8 I. AIR, GASES & ATMOSPHERE 1. Ambient Air PM 2.5 PM10 (RSPM) WMN/ENV/AIR/03, Issue no. 1 dated 01.10.2013 IS: 5182 (Part -23)-2006, 10 500 µg/m 3 10 1000 µg/m 3 Suspended

More information

Haryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Haryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide

More information

Nexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka

Nexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka Certificate Number TC-5069 (in lieu of T-3362 & T-3363) Page 1 of 17 Range ing / BIOLOGICAL TESTING I. WATER 1. Drinking Water R.O. Water, Ground Water, Surface Water, Treated Water. 2. Waste Water/ Effluents

More information

Deep Testing Laboratories, Plot No.- 338, Sector-58, Ballabhgarh, Faridabad, Haryana. Discipline Chemical Testing Issue Date

Deep Testing Laboratories, Plot No.- 338, Sector-58, Ballabhgarh, Faridabad, Haryana. Discipline Chemical Testing Issue Date Last Amended on - Page 1 of 6 I. METALS & ALLOYS 1. Plain Carbon & Low Alloy Steels Carbon IS 228 (Part-1) 1987, RA 2007 0.05% to 2.5% Mn IS 228 (Part-2) 1987, RA 2002 0.1% to 2.5% Si IS 228 (Part-8) 1989,

More information

Mahabal Enviro Engineers Pvt. Ltd. Pollution monitoring, Engineers & Contractors in Environmental Management

Mahabal Enviro Engineers Pvt. Ltd. Pollution monitoring, Engineers & Contractors in Environmental Management PROPOSED RESIDENTIAL CUM COMMERCIAL PROJECT WITH MCGM PARKING LOT, AT LOWER PAREL, MUMBAI, MAHARASHTRA GROUND WATER ANALYSIS October, 2017 Parameter Units Sample 1 Source Location Date of collection of

More information

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part

More information

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D

More information

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand Environment, Central Mine Planning and Design Institute Last Amended on - Page 1 of 9 1. POLLUTION & EFFLUENTS 1. Effluent / Waste Water Ammonical Nitrogen Free Ammonia IS 3025 (Part 34):1988, Nessler

More information

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh Madhya Pradesh Waste Management Project, Certificate Number TC-5022 (in lieu of T-2449) Page 1 of 8 CHEMICAL TESTING I. POLLUTION AND ENVIRONMENT 1. Waste Water (Effluent & Sewage) ph APHA 22nd Edition,

More information

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 6/9/2015

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 6/9/2015 Lake Huron Plant Turbidity NTU 0.35 0.05 0.3/95% (1) Total Solids mg/l 136 162 500 10 Total Dissolved Solids mg/l 145 136 500 10 Aluminum Al mg/l 0.510 0.142 0.05-0.2 0.005 Iron Fe mg/l 0.082 0.118 0.3

More information

Panasonic India Pvt. Ltd.

Panasonic India Pvt. Ltd. Panasonic India Pvt. Ltd. December-2014 FOR Industrial Building of Panasonic India Ltd At Jhajjar, Haryana 1 Details of Environmental Monitoring INTRODUCTION M/s Panasonic India Pvt Ltd granted its Environmental

More information

ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report

ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report Sampling Locations Near Bromine, Plant/Near ETP. Ambient Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB October November December Avg. 1 PM 10 µg/m 3 100 53 63 70 62 2 PM2.5 µg/m

More information

Lake Huron Water Treatment Plant Mineral Report

Lake Huron Water Treatment Plant Mineral Report Lake Huron Water Treatment Plant Mineral Report Turbidity NTU 0.40 0.05 0.3/95% (1) Total Solids mg/l 160 155 500 10 Total Dissolved Solids mg/l 101 0 500 10 Aluminum Al mg/l < 0.050 0.060 0.05-0.2 0.005

More information

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater; REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : ENVIRONMENTAL DATA - Temperature min. : C - Temperature max. : C - Altitude (m.a.s.l) : m - Plant location (geographic area, seismic zone,

More information

ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report

ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report Sampling Locations- Near Bromine, Plant/Near ETP. Ambient Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB 1 PM 10 µg/m 3 100 61 71 59 63.66 2 PM2.5 µg/m 3 60 16 24 18 19.33 3 Sulphur

More information

Submitted by: M/s Panasonic India Ltd

Submitted by: M/s Panasonic India Ltd Environmental Monitoring Report (June-2014) FOR Industrial Building of Panasonic India Ltd At Jhajjar, Haryana Submitted by: M/s Panasonic India Ltd INDUSTRIAL PLOT NO-1, VILLAGE- BID DADRI JHAJJAR (HARYANA)

More information

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 10/14/2014

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 10/14/2014 Lake Huron Plant Turbidity NTU 0.43 0.04 0.3/95% (1) Total Solids mg/l 103 116 500 10 Total Dissolved Solids mg/l 112 142 500 10 Aluminum Al mg/l < 0.050 < 0.050 0.05-0.2 0.005 Iron Fe mg/l 0.053 < 0.050

More information

Lake Huron Water Treatment Plant Mineral Report

Lake Huron Water Treatment Plant Mineral Report Lake Huron Water Treatment Plant Mineral Report Turbidity NTU 0.30 0.06 0.3/95% (1) Total Solids mg/l 94 91 500 10 Total Dissolved Solids mg/l 81 51 500 10 Aluminum Al mg/l < 0.050 < 0.050 0.05-0.2 0.005

More information

SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS

SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,

More information

Quality Marking & Testing Laboratory, M.P. Laghu Udyog Nigam Limited, Pologround Industrial Area, Indore, Madhya Pradesh

Quality Marking & Testing Laboratory, M.P. Laghu Udyog Nigam Limited, Pologround Industrial Area, Indore, Madhya Pradesh Quality Marking & Testing, M.P. Laghu Udyog Nigam Last Amended on 06.05.2015 Page 1 of 5 I. METALS & ALLOYS 1. Iron & Steel (Wrought, Cast Rolled and Fabricated items) 2. Copper & Copper Alloys Carbon

More information

GLOBAL TECH. ENVIRO EXPERTS PVT. LTD. (FORMERLY GLOBAL EXPERTS) An ISO-9001:2008 Certified Company

GLOBAL TECH. ENVIRO EXPERTS PVT. LTD. (FORMERLY GLOBAL EXPERTS) An ISO-9001:2008 Certified Company STACK MONITORING RESULT Name of Industry & Address Date of Monitoring 08-11-17 Date of Analysis 12-11-17 Reference No Stk-05/11/17 M/s SHIVA CEMENT LIMITED: Sl. No. Parameters Cement Mill 1 Kiln (Result)

More information

Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003

Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003 Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003 Parameters Units Averaging Time TSP (Total Suspended Particulars) Concentration in Ambient Air, maximum Test method µg/m 3 Annual - 24-hours*

More information

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3) NORTH TEXAS MUNICIPAL WATER DISTRICT - Wylie Water Analysis Jan-2018 Mineral Analysis Raw Treated Standards Residue on Evaporation 412 456 500 1000 Silica (SiO2) 3.63 3.41 Iron (Fe) 0.378 0.259 0.3 0.3

More information

MECON LIMITED RANCHI , INDIA

MECON LIMITED RANCHI , INDIA ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF JULY 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 SEPTEMBER, 2011

More information

ENVIRONMENTAL QUALITY STANDARDS REGULATIONS, 1999.

ENVIRONMENTAL QUALITY STANDARDS REGULATIONS, 1999. NATIONAL ENVIRONMENT MANAGEMENT ACT, 1994. ENVIRONMENTAL QUALITY STANDARDS REGULATIONS, 1999. IN EXERCISE of the powers conferred on the Council by sections 28(2) and 63(1) of the National Environment

More information

MECON LIMITED RANCHI , INDIA

MECON LIMITED RANCHI , INDIA ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF SEPTEMBER 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 OCTOBER, 2011

More information

ENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS

ENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS ENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS Disclaimer: The information contained in this communication document is intended solely for the use of guidance cannot be considered as

More information

Amol Pharmaceuticals Pvt. Ltd. (Analytical Division), E1-362, Sitapura Industrial Area, Jaipur, Rajasthan

Amol Pharmaceuticals Pvt. Ltd. (Analytical Division), E1-362, Sitapura Industrial Area, Jaipur, Rajasthan Last Amended on - Page 1 of 9 I. DRUG & PHARMACEUTICALS 1. a. Ibuprofen Identification (By IR) IP 2014, Vol. II, Page. 1941-1942 BP 2014 Vol. I Qualitative b. Ferrous Fumarate Identification (By IR) USP

More information

Point wise compliance for the conditions stipulated in Environmental Clearance of (Phase- I & II)

Point wise compliance for the conditions stipulated in Environmental Clearance of (Phase- I & II) SIX MONTHLY ENVIRONMENTAL COMPLIANCE STATUS REPORT (PERIOD : OCT, 2017 to MARCH, 2018) Ref: J-13011/23/2007-IA-II (T) Dated: 17/07/2007 (as amended in the Year, 2013 & 2014) and J-13011/46/2007-IA-II (T)

More information

Appendix I. Agreement on National Environmental Standards of Lao PDR, 2009

Appendix I. Agreement on National Environmental Standards of Lao PDR, 2009 Appendix I Agreement on National Environmental Standards of Lao PDR, 2009 I.1 DRINKING WATER QUALITY STANDARDS Lao PDR current standards for drinking water of the Lao PDR are provided below for reference.

More information

Topic Reacting masses Level GCSE Outcomes 1. To calculate reacting masses 2. To set out mole calculations in a grid format

Topic Reacting masses Level GCSE Outcomes 1. To calculate reacting masses 2. To set out mole calculations in a grid format Topic Reacting masses Level GCSE Outcomes 1. To calculate reacting masses 2. To set out mole calculations in a grid format Problems on Reacting Masses of Solids Section 1 1. What is the mass of magnesium

More information

Atmy Analytical Labs Pvt. Ltd., I-38, DLF Industrial Area, Phase-1, Faridabad, Haryana. Discipline Chemical Testing Issue Date

Atmy Analytical Labs Pvt. Ltd., I-38, DLF Industrial Area, Phase-1, Faridabad, Haryana. Discipline Chemical Testing Issue Date Last Amended on - Page 1 of 11 I. METAL & ALLOYS 1. Steel (Carbon Steel & Low Alloy Steel) Carbon ASTM E-415: 2014, IS 228 (Part 1): 1997 (RA 2008) 0.01 % to 1.5 % 0.01 % to 1.5 % Silicon ASTM E-415: 2014,

More information

Laboratory Turnaround Times and Prices

Laboratory Turnaround Times and Prices 4619 N. Santa Fe Ave. Oklahoma City, OK 73118 (405) 488-2400 Laboratory Turnaround Times and Prices The enclosed prices reflect a five (5) business day turnaround. There will be a minimum charge of $25.00

More information

Schedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005).

Schedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005). LABORATORY LOCATION: (PERMANENT LABORATORY) EUROFINS NM LABORATORY SDN. BHD. NO. 27, JALAN IMPIAN EMAS 5 TAMAN IMPIAN EMAS 81300 SKUDAI, JOHOR MALAYSIA Page: 1 of 6 FIELD OF TESTING: CHEMICAL This laboratory

More information

SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015)

SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015) SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015) ARA OCP (ARA SARUBERA GROUP OF MINES) KUJU AREA CENTRAL COALFIELDS LIMITED (A Miniratna

More information

LABORATORY TURNAROUND TIMES AND CHARGES

LABORATORY TURNAROUND TIMES AND CHARGES LABORATORY TURNAROUND TIMES AND CHARGES The enclosed prices reflect a 5 business day turnaround time. There will be a $25.00 minimum charge per report. Same Day Rush 24 Hour Rush 48 Hour Rush 72 Hour Rush

More information

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS 1 CERTIFICATE OF ANALYSIS ATTENTION: Water Purification Solutions DATE: 29 November 2018 1. GENERAL: Table-1: Tierkloof Borehole & Product - Sampled 1 November 2018 Results expressed in parts per million

More information

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits

Chemical Test Kits. Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Table of Contents Introduction Reference Table Single Parameter Test Kits Multiparameter Test Kits Page A2 A4 A6 A20 A1 Single Parameter Simple and Economical Analysis HANNA instruments test kits are the

More information

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road October 27 2010 Inorganics Fluoride 1.5 MAC 0.17 0.13

More information

Appendix U. Mapping of Water Quality Concentration Contours across the Province

Appendix U. Mapping of Water Quality Concentration Contours across the Province ALDERON IRON ORE CORP. ENVIRONMENTAL IMPACT STATEMENT KAMI IRON ORE MINE AND RAIL INFRASTRUCTURE, LABRADOR Appendix U Mapping of Water Quality Concentration Contours across the Province Figure 17I.1 Alkalinity

More information

APPENDIX I. LAMPIRAN I - RKL DAN RPL KEGIATAN TERPADU PROYEK PENGEMBANGAN TANGGUH LNG i

APPENDIX I. LAMPIRAN I - RKL DAN RPL KEGIATAN TERPADU PROYEK PENGEMBANGAN TANGGUH LNG i APPENDIX I Table 1 Emission Standards from Flare, Gas Turbine, Boiler, Acid Gas Incinerator and Internal Combustion Engine... 1 Table 2 n-hazardous Waste Incinerator Standard... 3 Table 3 Hazardous Waste

More information

Hitech Healthcare Laboratory and Research Centre, 201, Sahaj Arcade, Science City Road, Ahmedabad, Gujarat

Hitech Healthcare Laboratory and Research Centre, 201, Sahaj Arcade, Science City Road, Ahmedabad, Gujarat Last Amended on 06.09.2016 Page 1 of 20 I. WATER 1. Packaged Packaged Natural Mineral Water, Treated Water, Colour IS 3025 (Part 4): 1983 (RA 2002), Amd. 1: March 2007 Odour IS 3025 (Part 5): 1983 (RA

More information

Appendix C: Water Quality Data

Appendix C: Water Quality Data Appendix C: Water Quality Data Your Project #: 111257005 Site: TIM HORTONS SYLVIA LAKE NSD # 16300R Attention: DAVID WHETTER STANTEC CONSULTING LTD 603-386 BROADWAY AVENUE WINNIPEG, MB CANADA R3C

More information

Abuja, May 2008

Abuja, May 2008 Waste Water Treatment and Water Quality Based on UNSD Questionnaire 2002 and 2004 United Nations Statistics Division Workshop on Environment Statistics Abuja, 19-23 May 2008 Waste water generation Total

More information

National Accreditation Board for Testing and Calibration Laboratories. (A Constituent Board of Quality Council of India) CERTIFICATE OF ACCREDITATION

National Accreditation Board for Testing and Calibration Laboratories. (A Constituent Board of Quality Council of India) CERTIFICATE OF ACCREDITATION (? (A Constituent Board of uality Council of India) C I CERTIFICATE OF ACCREDITATION M.E. TESTING LABORATORY has been assessed and accredited in accordance with the standard ISO/IEC 17025:2005 "General

More information

ANNEXURE- II Proposed TOR

ANNEXURE- II Proposed TOR ANNEXURE- II Proposed TOR Annexure II Terms of Reference for EIA for Setting up of Ligno-Cellulosic Biomass based second generation (2G) Ethanol Bio-Refinery with capacity of 100 KLPD at village-sainjani,

More information

Tolerance and Classification

Tolerance and Classification Tolerance and Classification As per ISI-IS: 2296-1982, the tolerance limits of parameters are specified as per classified use of water (Table 1,2,3,4,5 below) depending on various uses of water. The following

More information

ZZL/CLAB-KSPCB/17/ Environmental Officer,

ZZL/CLAB-KSPCB/17/ Environmental Officer, ZZL/CLAB-KSPCB/17/ 3657 10-10-2018 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwada

More information

CALA Directory of Laboratories

CALA Directory of Laboratories CALA Directory of Laboratories Membership Number: 2907 Laboratory Name: Avalon Laboratories Inc. Parent Institution: Avalon Laboratories Inc. Address: 85C Bremigens Blvd Paradise NL A1L 4A2 Contact: Ms.

More information

ZZM/CLAB-KSPCB/17/ Environmental Officer,

ZZM/CLAB-KSPCB/17/ Environmental Officer, ZZM/CLAB-KSPCB/17/ 399 08-02-2019 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwada

More information

3. Up stream & Downstream water quality monitoring report of Kali River. ZZM/CLAB-KSPCB/17/ Environmental Officer,

3. Up stream & Downstream water quality monitoring report of Kali River. ZZM/CLAB-KSPCB/17/ Environmental Officer, ZZM/CLAB-KSPCB/17/ 724 12-03-2019 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwada

More information

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers

DelAgua Safe Water. Reagent Identification Chart for Lovibond Tintometer photometers DelAgua Safe Water Reagent Identification Chart for Lovibond Tintometer photometers For Use: Identify the parameter required, ensure the parameter matches your photometer, codes required for the test are

More information

Schedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent

Schedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent LABORATORY LOCATION: (PERMANENT LABORATORY) Page: 1 of 12 SPECTRUM LABORATORIES (PENANG) SDN. BHD. 1904 TINGKAT 1, JALAN BUKIT MINYAK TAMAN SRI MANGGA, 14000 BUKIT MERTAJAM SEBERANG PRAI TENGAH PULAU PINANG

More information

ZZL/CLAB-KSPCB/17/ Environmental Officer,

ZZL/CLAB-KSPCB/17/ Environmental Officer, ZZL/CLAB-KSPCB/17/ 160 08-01-2018 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwadaa

More information

CERTIFICATE OF ANALYSIS

CERTIFICATE OF ANALYSIS Your C.O.C. #: 32531001 Attention: Scott Churko Engineering and Operations Dpt PO Box 1390 Parksville, BC Canada V9P 2H3 CERTIFICATE OF ANALYSIS MAXXAM JOB #: B279455 Received: 2012/09/06, 09:15 Sample

More information

ANALYTES available for testing

ANALYTES available for testing ANALYTES available for testing codes WS = water supply, drinking water, potable water WP = wastewater, general water quality, ODA OK = Oklahoma DEQ ODA = Oklahoma Department of Agriculture KS = Kansas

More information

ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA

ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA Managed by Ministry of Science, Technology And The Environment Malaysia Concept of the National Policy Of The Environment 1 MALAYSIA POLICY ON THE ENVIRONMENT

More information

Central Institute of Fisheries Technology, Matsyapuri P.O., Willingdon Island, Cochin, Kerala. Discipline Chemical Testing Issue Date

Central Institute of Fisheries Technology, Matsyapuri P.O., Willingdon Island, Cochin, Kerala. Discipline Chemical Testing Issue Date Last Amended on Page 1 of 7 I. WATER 1. Ice / Water (Drinking water, Processing water and effluent water) ph APHA 2012 22 ed : 4-91-96 Total Dissolved Solids APHA 2012 22 ed :, 2.65 Total Hardness APHA

More information

ZZK/CLAB-KSPCB/04/ Environmental Officer,

ZZK/CLAB-KSPCB/04/ Environmental Officer, ZZK/CLAB-KSPCB/04/ 5491 09-10-2017 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwadaa

More information

KASIA IRON AND DOLOMITE MINE SIX MONTHS REPORT (OCTOBER, 2011 MARCH, 2012)

KASIA IRON AND DOLOMITE MINE SIX MONTHS REPORT (OCTOBER, 2011 MARCH, 2012) MONITORING OF BASELINE ENVIRONMENTAL PARAMETERS KASIA IRON AND DOLOMITE MINE Area of the mine: 194.196 Ha Kasia Village, Barbil Tehsil, Champua Sub Division, Keonjhar District, Odisha Of SIX MONTHS REPORT

More information

2019 Microbac Laboratories Inc. Ohio Valley Division

2019 Microbac Laboratories Inc. Ohio Valley Division STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES LABORATORY CERTIFICATION BRANCH In accordance with the provisions of N.C.G.S. 143-215.3 (a) (1), 143-215.3 (a)(10)

More information

Table B1: Analytical Results for Nutrients in Surface Water

Table B1: Analytical Results for Nutrients in Surface Water Table B1: Analytical Results for Nutrients in Surface Water Sample ID 1 2 Physical Tests Colour, True (Colour Units) 15 (4) units absolute, or 5 units above background (30-day average)

More information

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation Matrix: CWA (Non Potable Water) Discipline: Chemistry ASTM D516-07 ASTM D6888-09 ASTM D7511-09e2 EPA 160.4 EPA 1631E EPA 1664A EPA 1664A (SGT-HEM) EPA 180.1 Sulfate 8/1/2018 Cyanide, Amenable 8/1/2018

More information

Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014

Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014 Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July 2013-30 June 2014 Durban Heights WW Raw Durban Heights WW Final Determinands Units Minimum Average Percentile Maximum Minimum Average

More information

Environmental Protection Agency

Environmental Protection Agency PO Box 3000, Johnstown Castle Estate, Wexford Testing Laboratory Registration number: 113T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the

More information

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY

2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY THE WATER ACT, 1956 (ACT 54 OF 1956 ) AND ITS REQUIREMENTS IN TERMS OF WATER SUPPLIES FOR DRINKING WATER AND FOR WASTE WATER TREATMENT AND DISCHARGE INTO THE ENVIRONMENT 1. INTRODUCTION The provisions

More information

Chapter 1 (BFC32403) and Standards

Chapter 1 (BFC32403) and Standards Chapter 1 (BFC32403) Environmental Rules, Regulations and Standards 1 ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA Managed by DOE Concept of the National Policy Of The Environment 2 DEPARTMENT

More information

REVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS)

REVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS) REVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS) Background PEPC in its first meeting held on 10 th May 1993 approved the NEQS. The approved NEQS were uniform standards applicable to all kind of

More information

Discipline Chemical Testing Issue Date Certificate Number T-2133 Valid Until Last Amended on

Discipline Chemical Testing Issue Date Certificate Number T-2133 Valid Until Last Amended on Location 2: Plot No. 195, Ward No. DC-2, Gandhidham, Last Amended on 23.02.2015 Page 1 of 5 I. COAL, COKE & OTHER SOLID FUELS 1. Coal Total Moisture IS 1350 (Part 1): 1984 (RA 2007) ASTM D 3302/ D3302M-12

More information

We are sending herewith the following for the month of September 2016.

We are sending herewith the following for the month of September 2016. ZZJ/CLAB-KSPCB/04/6499 07-10-2016 Environmental Officer, Regional Office, Karnataka State Pollution Control Board, Parisara Bhavan, LIG II, B 217, B-1, Main Road, A-16th Cross, Near Hari Om Trust, Habbuwada,

More information

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent

Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent wastewater requirements. In Russia, there are strict

More information

CALA Directory of Laboratories

CALA Directory of Laboratories CALA Directory of Laboratories Membership Number: 4114 Laboratory Name: African Assay Laboratories Ltd (Tanzania)- Environmental Laboratory Parent Institution: Address: Balewa Road Mwanza 255 Contact:

More information

Chapter 2 LEGISLATIVE FRAMEWORK

Chapter 2 LEGISLATIVE FRAMEWORK Chapter 2 LEGISLATIVE FRAMEWORK 2.1 Introduction Over the last 20 years, Mauritius has implemented a number of environmental acts and regulations aimed at controlling the environmental impact resulting

More information

Waste Water (Standards for Discharge of Industrial Effluent into a Waste Water System) Regulations 2004

Waste Water (Standards for Discharge of Industrial Effluent into a Waste Water System) Regulations 2004 Waste Water (Standards for Discharge of Industrial Effluent into a Waste Water System) Regulations 2004 GN No. 82 of 2004 THE WASTE WATER MANAGEMENT AUTHORITY ACT Regulations made by the Minister under

More information

Water Chemistry. Water 101

Water Chemistry. Water 101 Water Chemistry Water 101 I. Introduction A. Water is not pure Many different kinds of chemicals dissolved in it Ions, organic chemicals, organic matter, particulate matter, and gases can all be in water

More information

Schedule of Accreditation

Schedule of Accreditation Schedule of Accreditation Organisation Name TMS Environment Ltd INAB Reg No 150T Contact Name Marian Brady Address 53 Broomhill Drive, Tallaght, Dublin Contact Phone No 01-4626710 Email mbrady@tmsenv.ie

More information

Annex 2: National Environmental Quality Standards (Extract from the Gazette of Pakistan applicable to STZ CETP)

Annex 2: National Environmental Quality Standards (Extract from the Gazette of Pakistan applicable to STZ CETP) Annex 2: National Environmental Quality Standards (Extract from the Gazette of Pakistan applicable to STZ CETP) 1290 THE GAZETTE OF PAKISTAN, EXTRA, AUGUST 10, 2000 [PART-II] (1) For Annex, I the following

More information

Schedule of Accreditation

Schedule of Accreditation Schedule of Accreditation Organisation Name Sourn Scientific Services INAB Reg No 194T Contact Name Catriona Donovan Address Unit 4, 4Park Business Centre, Farranfore, Kerry Contact Phone No 0669763588

More information

Formula & Equation Writing

Formula & Equation Writing Formula & Equation Writing Book 2 H H Al Al H Al(H) 3 H Ionic Equations Ionic Formulae Balanced Equations Formula Equations Word Equations Transition Metals Using Brackets Awkward Customers More than 2

More information

CHARACTERIZATION OF TEXTILE WASTEWATER

CHARACTERIZATION OF TEXTILE WASTEWATER CHARACTERIZATION OF TEXTILE WASTEWATER 137 Jr. of Industrial Pollution Control 20 (1) (2004) pp. 137-144 Enviromedia Printed in India. All rights reserved CHARACTERIZATION OF TEXTILE WASTEWATER J. Hussain,

More information

1. How many moles of calcium chloride are there in a sample containing x particles? l

1. How many moles of calcium chloride are there in a sample containing x particles? l 1. How many moles of calcium chloride are there in a sample containing 1.0038x 10 22 particles? l 2. A sample of water contains 3.01x10 23 water molecules a. How many moles of water molecules are present

More information

Period: to

Period: to Half Yearly Compliance Report on Environmental Surveillance Monitoring & Compliance Status with respect to condition of Environmental Clearance vide letter No. J-11011/97/2004-IA.II (I) dated 2 nd December,

More information

Environmental Management System

Environmental Management System Environmental Management System Moreton Bay Research Station (MBRS) Water Management Program 1. Program Scope The Water Management Program incorporates all the water used throughout the Moreton Bay Research

More information

Independent Analytical Supplies Ltd (Trading as) IAS Laboratories

Independent Analytical Supplies Ltd (Trading as) IAS Laboratories Independent Analytical Supplies Ltd (Trading as) IAS Laboratories Unit 4 Bagenalstown Business Park, Bagenalstown, Co Carlow Testing Laboratory Registration number: 275T is accredited by the Irish National

More information

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to: April 11, 2017 Mr. Brad Barfuss 350 Hills Street Suite 107 Richland, WA 99354 Dear Mr. Barfuss: Thank you for your application for renewal in the Environmental Laboratory Accreditation Program. Enclosed

More information

Goldfields Environmental Management Group Workshop on Environmental Management Kalgoorlie-Boulder, May 2010

Goldfields Environmental Management Group Workshop on Environmental Management Kalgoorlie-Boulder, May 2010 Goldfields Environmental Management Group Workshop on Environmental Management Kalgoorlie-Boulder, May 2010 MBS Environmental Geochemical Capabilities Waste characterisations for projects in WA, NT & Qld:

More information

Appendix C1: Batch Kinetics Tests

Appendix C1: Batch Kinetics Tests Appendix C1: Batch Kinetics Tests This appendix contains the entire data set for the batch kinetics tests for the potential biofilter components. These tests were performed to provide estimates of optimal

More information

AIR, WATER AND METEOROLOGICAL MONITORING JUNE 2018 PINE DALE MINE, BLACKMANS FLAT

AIR, WATER AND METEOROLOGICAL MONITORING JUNE 2018 PINE DALE MINE, BLACKMANS FLAT AIR, WATER AND METEOROLOGICAL MONITORING JUNE 2018 PINE DALE MINE, BLACKMANS FLAT Prepared for Pine Dale Mine Community Consultative Committee Prepared by RCA Australia RCA ref 6880-1771/0 RCA AUSTRALIA

More information

W12A Landfill Groundwater, Leachate, Water Well, Landfill Gas and Surface Water Quality Monitoring Program

W12A Landfill Groundwater, Leachate, Water Well, Landfill Gas and Surface Water Quality Monitoring Program W12A Landfill Groundwater, Leachate, Water Well, Landfill Gas and Surface Water Quality Monitoring Program The groundwater, leachate, water well, landfill gas and surface water monitoring programs are

More information

SOIL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SWIMMING POOL TEST KIT

SOIL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SWIMMING POOL TEST KIT INDIVIDUAL TEST KITS MULTI PARAMETER TEST KITS SOIL TEST KIT SWIMMING POOL TEST KIT 01 Analyzing Waters Anytime... Anywhere... AQUASOL test kits are extremely simple and easy to use & make monitoring convenient

More information

Kits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT

Kits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT Kits Item Product name Article Number 1 ACIDITY TEST AQUAMERCK 1.11108.0001 2 ALCOHOL TEST 15-150 MG/L REFLECTOQUANT 1.17946.0001 3 ALKALINITY TEST AQUAMERCK 1.11109.0001 4 ALUMINIUM TEST 0.020-1.20 MG/L

More information

462 - Solids, Total Dissolved 630 mg/l

462 - Solids, Total Dissolved 630 mg/l Phone : (608) 252-7935 Permit : 0063088 801/MW-1 Infiltration Area Well WI Unique No: Date: 03/23/2016 Casing Top Elevation New(Feet, MSL): 1006.92 Well Is: Broken: N Frozen: N Dry: N Has: Odor: N Color:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELICROM CÍA. LTDA. Cdla. Guayaquil, Mz 21 Calle Primera, Solar 10 Guayaquil, Ecuador 090506 Camilo Moreno Phone: 593 4 2282007 CHEMICAL Valid To: August 31,