PRELIMINARY BROCHURE
|
|
- Muriel Hubbard
- 5 years ago
- Views:
Transcription
1 FOURTH GENERATION HIGH RESOLUTION PRECISION REFERENCE METHOD GAS ANALYSERS FOR STAND ALONE USE GAS FILTER CORRELATION CO, CO 2, NO, SO 2, N 2 0, CH 4 + MORE CHEMILUMINESCENCE NOx, NO 2, NO FLAME IONIZATION TOTAL HYDROCARBONS, CH 4, VOC PARAMAGNETIC O 2 FOR SYSTEMS INTEGRATION PRELIMINARY BROCHURE
2 SERIES 4 COMMON PLATFORM GRAPHICAL USER INTERFACE (GUI) Colour touch screen SD card flash memory logging all channels USB for uploads/downloads Displays: readings, chart traces, flow rates, alarms, faults, linearization function COMMUNICATIONS I/O RS232, Ethernet, (TCP/IP with IP address), AK Protocol, CAN Bus (optional), 0-10VDC, 4-20mA, 35 contact closures (all programmable). REMOTE COMPUTER SOFTWARE MODULE (running on Windows OS)
3 PULSAR CLASS GAS FILTER CORRELATION NDIR TYPICAL GASES: CO, CO 2, NO, SO 2, N 2 O, CH 4 + MORE Gas Filter Correlation is the best type of NDIR for combustion gas analysis. Instead of a dual beam sample cell and a separate reference cell, this method uses only a single cell for both sample and reference. This method reduces problems with cell contamination causing a difference in readings. Also, with Gas Filter Correlation we fill the filter wheel interfering gases e.g. H 2 O, CO 2 to eliminate the effects of these gases when measuring for example low CO in the presence of percent levels of these other gases. The Pulsar class also provides superior levels of linearity throughout the 10,000:1 range ratio. HIGH RESOLUTION WIDE DYNAMIC RANGE 10,000:1 LOW CO, for example, 0-10, 0-50, 0-100, 0-500, ppm +/- 1% LINEARITY 24V DC VERSION
4 SERIES 4 TECHNICAL SPECIFICATION - PULSAR MULTIGAS NDIR o o o o o Available in 1, 2, 3, 4, or 5 gas channel configurations New design for improved specification Supplied with software suite for use over Ethernet or RS232 Suitable for ultra-low measurement range applications Rotating filter design for minimal cross sensitivity The new Pulsar detector from Signal has been upgraded to provide our best ever performance specification. With the lowest drift on the market it is ideal for low range applications or high accuracy measurement. The GFC design of the detector prevents cross sensitivity to other gases and also removes the risk of contamination through a sample containing particulate matter. It provides a cost effective, low maintenance option for even low concentration measurement applications. Ambient Operating and Storage Conditions Operating temperature: 5 C to 40 C Storage temperature: -12 C to 40 C Max operating humidity: 80%RH Storage max humidity: 80%RH Inlet pressure: Up to 2 bar Sample temperature: maximum 40 C Power requirements: VAC 50/60Hz or 24V DC Universal Sample dewpoint: below local ambient temperature Construction Materials Wetted: stainless steel 316, PTFE, quartz in paramagnetic O 2 detector Output Signals Ethernet as standard. Optional 4-20mA and 0-10V DC. Onboard logging included with screen option. Linearity < ±0.5% of range or 2% of reading Intercept 0.5% range Slope 1.01 SEE 1.0% range R Repeatability < ±1% of range or ±0.5ppm, whichever is greater Drift Zero: <1% FS/24h, <2% of range per week Span: <1% FS/24h, <4% of range per week Response Time T90 <5s Dependent on gas and cell length. See page 2 for individual values Warmup Time Useable: 5 minutes Operation to specification: 1 hour Ambient Temperature Effect Zero and Span: <0.2% of range per C Flow Sensitivity 0.1% of range per L/min Sample Filter Pore Size 10 micron
5 SERIES 4 TECHNICAL SPECIFICATION -gas specific values Gas/Range Zero Noise/LDL Span Noise Response Time*, T 90 Cross Sensitivities (Raw signal) ** (Raw signal)** Carbon Monoxide (CO) -10ppm ~ ppm 0.1ppm/0.5ppm <1% reading < 3 seconds 100% CO 2 :< ±1ppm -50ppm ~ ppm <1ppm / 2ppm <1% reading <3 seconds 1% CH 4 :< ±1ppm -0.1% ~ 0-10% <0.01%/0.02% <1% reading < 2 seconds 1% N 2O :< ±3ppm -0.2% ~ 0-20% <0.05%/ 0.1% <1% reading <2 seconds 2.3%H 2O/N 2 :< ±3ppm Carbon Dioxide (CO 2) -10ppm ~ ppm 0.1ppm/0.2ppm <1% reading <2 seconds 100% CO :< ±2ppm 0-100ppm~ 0-10,000ppm <1ppm/ 2ppm <1% reading <2 seconds 1% CH 4 :< ±1ppm 0-0.1~ 0.10% <0.01%/ 0.02% <1% reading <1 second 2.3%H 2O/N 2 :< ±1ppm 0.02~0-20% <0.05 / 0.1% <1% reading <1 second 0-1% ~ 0-100% <0.2/0.4% <1% reading <1 second Nitrous Oxide (N 2O) -10ppm ~ ppm <1.0ppm/2ppm <1% reading <5 seconds 1000ppm CO :< ±2ppm -100ppm ~ 0-10,000ppm <10ppm/20ppm <1% reading <3 seconds 10% CO :< ±36ppm 10% CO 2 :< ±1ppm 20% CO 2 :< ±3ppm 2.3%H 2O/N 2 :< ±2ppm Nitric Oxide (NO) 0-10ppm ~ ppm <2.0ppm / 4ppm <2% reading <2 seconds 10% CO :< ±2ppm 0-100ppm ~ 0-10,000ppm <20ppm / 40ppm <2% reading <2 seconds 10%CO 2 :< ±1ppm 500ppmCH 4 :< ±1ppm 2.3%H 2O/N 2 :< ±10ppm Sulphur Dioxide (SO 2) 0-10ppm ~ ppm <1.0ppm / 2ppm <1% reading <5 seconds 5000ppm CO :< ±4ppm 0-100ppm ~ 0-10,000ppm <10ppm / 20ppm <1% reading <3 seconds 10% CO 2 :< ±2ppm 500ppm CH 4 :< ±15ppm 2.3%H 2O/N 2 :< ±15ppm Methane (CH4) -10ppm ~ ppm <2ppm/4ppm <1% reading <5 seconds 100% CO :< ±5ppm 0-100ppm ~ 0-10,000ppm <20ppm/ 40ppm <1% reading <4 seconds 100% CO 2 :< ±25ppm 0-1% ~ 0-10% <0.1% / 0.2% <1% reading <2 seconds 2.3%H 2O/N 2 :< ±5ppm Hydrogen Chloride (HCl) -10ppm ~ ppm <4ppm / 8ppm <1ppm <5 seconds 100% CO :< ±2ppm 0-100ppm ~ 0-10,000ppm <40ppm / 80ppm <20ppm <5 seconds 10% CH4 :< ±150ppm 500ppmCH 6H 14 :< ±2ppm *based on sample flow at 1 L/min **User configurable adaptive averaging can be used to improve noise specification
6 QUASAR CLASS CHEMILUMINESCENCE DETECTOR The Signal Quasar series of Chemiluminescence NOx analysers is unique in the market with the very special ozone generator and the low level of quenching effects from CO 2 and H 2 O. The soft discharge neon lamp ozone generator is unique among competitors with its ability to use air as its feed gas without any Nitrogen in the air becoming NO and NO 2. High voltage corona discharge techniques and UV lamps both suffer from this and major competitors recommend the use of 100% Oxygen to avoid this effect, and this is expensive compared to air. The high vacuum and heated design also eliminates quenching and increases signal strength and also avoids any condensation in the sample and measurement which could cause losses of NO 2 in condensate. The vacuum pump is of a dry diaphragm design. We offer a single NOx detector, dual continuous NO, NO 2, NOx detectors, non vacuum for dilute and dry samples (e.g. CVS vehicle testing, off road dry NOx testing), and NOx, NH 3, NO 2 using selective converters and dual continuous detectors. ELECTRONIC PROPORTIONAL BAND FLOW CONTROLLERS VERY LOW QUENCHING FROM CO 2 and H 2 O SPECIAL OZONE GENERATOR USES AIR AS FEED GAS LONG LIFE NOx CONVERTER (5 YEARS) DRY, LOW MAINTENANCE VACUUM PUMP 24V DC VERSION
7 SERIES 4 TECHNICAL SPECIFICATIONS - QUASAR CHEMILUMINESCENCE Ranges Linearity 0-1 ppm, ppm 0-10 ppm, 0-10,000 ppm ± 1% of value Response Time T seconds Converter Efficiency 95% Converter Life time < 5 years Temperature Effect 0.3%/ C Pumps Vacuum: Dry type Maintenance: 6 months diaphragm change Motor: Maintenance free Bypass: Maintenance: 6 months diaphragm change Motor: Maintenance free Power V AC 50/60Hz Universal or 24V DC Ozonizer Feed Gas Self contained air supply Quenching CO 2 : less than 1% for 10% CO 2 H 2 O: less than 1% for 3% H 2 O
8 SOLAR CLASS FLAME IONIZATION DETECTOR The Signal Solar Flame Ionization Detector product line is unique in the market with its precision machined, monobloc arrangement of ceramic isolated flame jet tip cylindrical collector and venturi effect air/fuel/sample design. This has produced reproducibility of production so that every analyser has exactly the same characteristics. The need for this uniformity is important when measuring hydrocarbons as there are many different species in the measurement mix and barometric changes can be a problem. The monobloc design encompasses the hot oven, the heated filter, span/zero/cal valve and the sample pump. Thus, a very compact and leak proof design is provided. The sample pump uses a brushless DC motor for total reliability. We offer a heated 191 C single FID for total hydrocarbon, a Methane only single FID using a cutter to remove/convert all hydrocarbons except for Methane, and a dual detector for continuous total hydrocarbons, Methane, and non Methane. ELECTRONIC PROPORTIONAL BAND FLOW CONTROLLERS AUTOMATIC FLAME OPTIMIZATION PROGRAM SPECIAL HIGH EFFICIENCY HC CUTTER CERTIFIED CONFORMITY TO EN12619:2013 QUAL1 24V DC VERSION
9 SERIES 4 TECHNICAL SPECIFICATIONS - SOLAR FLAME IONIZATION DETECTOR Ranges Linearity 0-1 ppm, ppm 0-10 ppm, 0-10,000 ppm ppm, 0-100,000 ppm ± 1% of value Response Time T seconds Cutter Efficiency 95% Cutter Life time < 3 years Temperature Effect 0.3%/ C Effect of Oxygen 0.3% reading from Zero - 10% O 2 in sample Response factors with respect to Propane N-Butane Ethyl Acetate Isopropanol N-heptane P-xylene Benzene Toluene Methane Dichloromethane Isobutyl Acetate Chlorobenzene Cyclohexane Ethyl Benzene Acetylene Tetrachloroethylene Power V AC 50/60Hz Universal or 24V DC Certified to EN12619:2013 QAL1 Fuel Hydrogen 80 ml/min Hydrogen/Helium 160 ml/min or Air Self contained using a catalytic scrubber * for 0-1 ppm bottled synthetic air is recommended
10 Signal Series 4 Model Numbers Heated FID based analysers: HFID THC Single THC HFID NMHC Single, switched cutter THC, CH4, NHMC HFID DNMHC Dual THC, CH4, NMHC Cold FID based analysers: CFID THC Single THC CFID NMHC Single, switched cutter THC, CH4, NMHC CFID CH4 Single, methane only CH CFID DTHC Dual THC1, THC FID based analysers for ambient measurement: CFID ANMHC Single, switched cutter THC, CH4, NHMC Vacuum CLD based analysers: VCLD NOx Single, switched NOx converter NO, NOx VCLD NO2 Single, switched converter NO, NOx, NO2 VCLD NH3 Single, switched NOx converter and NH3 converter NO, NOx, NO2, NH3, TN (Total Nitrogen) VCLD TN Single, switched NH3 converter NO, TN VCLD DNO2 Dual, NOx converter NO, NOx, NO2 VCLD DTN Dual, NH3 converter NO, TN Ambient pressure reaction chamber CLD based analysers: CLD NOx Single, switched NOx converter NO, NOx CLD NO2 Single, switched NOx converter NO, NOx, NO2 CLD DNO2 Dual, NOx converter NO, NOx, NO2 CLD based analysers for ambient measurement: CLD ANO2 Single, switched NOx converter NO, NOx, NO2 GFC based analysers (each bench is single OR dual range): GFC10 GFC20 GFC11 GFC21 GFC22 GFC10P GFC20P GFC11P GFC21P GFC22P Single bench (folded path allowable) Dual bench (folded path allowable on both) Twin single benches (folded path allowable on both) One dual & one single bench (folded path allowable on the single bench) Twin dual benches (no folded path allowable) Single bench (folded path allowable), with oxygen analyser Dual bench (folded path allowable on both), with oxygen analyser Twin single benches (folded path allowable on both), with oxygen analyser One dual & one single bench (folded path allowable on the single bench), with oxygen analyser Twin dual benches (no folded path allowable), with oxygen analyser
11 Single Beam (SB) based analysers: SBIR10 SBIR11 SBIR30 SBIR40 SBIR10P SBIR11P SBIR30P SBIR40P Single bench Twin single benches Three single benches Four single benches Single bench, with oxygen analyser Twin single benches, with oxygen analyser Three single benches, with oxygen analyser Four single benches, with oxygen analyser Luft (dual beam) based analyser: DBIR - x Where x is the gas measured (e.g. NH3, etc) Paramagnetic based analyser: PMAG O2 Oxygen only UV Photometer based analyser for ambient measurement: UVP AO3 Ozone only UV Fluorescence based analyser for ambient measurement: UVF ASO2 UVF AH2S SO2 only SO2 & H2S, switched H2S converter
12 APPLICATIONS USING SIGNAL SERIES 4 ANALYSERS AUTOMOTIVE Engine Test Cells: Vehicle Cells: Sheds: Other: Raw Exhaust Cat Efficiency Diesel/Gasoline/Alternative Fuels EPA CFR40, EURO 4-6 regulations EPA CFR compliant Dilute CVS emissions Vehicle Certification EPA CFR40, EURO 4-6 regulations EPA CFR compliant ULEV, SULEV, SORE Evaporative Hydrocarbons Running Loss CONTINUOUS EMISSIONS SYSTEMS CCGT, CHP Low NOx combustors, stationary engine standby power Coal fired power stations Carbon capture and storage COMBUSTION Boiler testing: domestic appliance, industrial heaters Fire materials testing ENVIRONMENTAL MONITORING Certified stack testing laboratories RESEARCH AND UNIVERSITIES Combustion research Chemical engineering Carbon capture and storage Engine development/gas turbine/diesel/catalyst development/efficiency VOC MONITORING SYSTEMS Paint and coating processes Print processes Waste incineration: lower ppm VOC monitoring (1-5 ppm) OTHER Tobacco fumes testing Pure gas impurities Medical gas NO in N 2 O Hydrocarbon trace in air separation processes Contact sales@signal-group.com +44 (0)
Fpollutant-free zero air for analytical
Ambient Air Quality Monitoring System AQMS-100 Zero Air Generator PI AQMS-100 provides ultra pure Fpollutant-free zero air for analytical purpose. Remote monitoring and configuration can also be achieved
More informationHeated FID OVF Portable THC/TVOC Analyzer
Heated FID OVF-3000 Portable THC/TVOC Analyzer The OVF-3000 is light weight and portable, competitively priced compact and fully heated FID (HFID) based total hydrocarbon analyzer for high accuracy, sensitivity
More informationTVOC Heated FID VE 7
Rack Mount/Table Top THC Analyzer TVOC Heated FID VE 7 The VE7 19"/5PU rack mount and table top heated emission analyzer for the continuous determination of the mass concentration of total gaseous organic
More informationHeated FID 109A. Rack Mount/Table Top NMGOC Analyzer
Rack Mount/Table Top NMGOC Analyzer Heated FID 109A J.U.M. Engineering 2014/2016 The 109A is a rack mount and table top heated emission analyzer for the continuous / simultaneous determination of the mass
More informationEuroFID Total Hydrocarbon Analyzer
Product information EuroFID Total Hydrocarbon Analyzer Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases Analyzers and Process Instrumentation Proven Analyzer
More informationEXM500. Online Gas Analyser. Specialist Of UV Spectroscopy
EXM500 Online Gas Analyser Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Kodda / agence 123rf Page intérieur : Bagiuiani / agence 123rf > EXM500 Online Gas Analyser The
More informationRoad Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels
TunnelTech 404 CODEL NO2, and Visibility Air Quality Monitor Road Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels High accuracy determination of
More informationOnline Gas Analyzer / Monitor
Sheet No. 1 of 9 CH4 H2 SOX NOX NH3 CO2 HF HCL HCN CO O2 Providing the latest in Combustion Gas & Emission Analyzers for Boiler, Engine, Furnace, and other applications. Sheet No. 2 of 9 Vasthi OMGA 8000
More informationCEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy
CEM500-L Online Gas Analyser Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Kodda / agence 123rf Page intérieur : Bagiuiani / agence 123rf > CEM500-L Online Gas Analyser
More informationAnalyzer Module Wet Chemiluminescence Detection (WCLD)
Product Data Sheet PDS 103-670.A01 October, 2003 NGA 2000 Heated NO/NO x Analyzer Module Wet Chemiluminescence Detection (WCLD) Heated sample handling module for hot/ wet gas samples Eliminates loss of
More informationmadur GA21p-EN-v portable gas analyser
www..com portable gas analyser GA21plus is a portable analyser using advanced technologies. However, it remains s flagship due to its favorable price. It can be equipped with up to 9 electrochemical and
More informationCO Sensor Response Study NO & NOx Analyzer Validation. June 6, 2018
CO Sensor Response Study NO & NOx Analyzer Validation June 6, 2018 HOW TO MEASURE MULTIPLE ZONES Sensor Options Available Passive sensors Small and easy to use Rely on diffusion to reach sensor Vacuum
More informationContinuous Emissions Monitoring in Support of the Cement MACT
Continuous Emissions Monitoring in Support of the Cement MACT McIlvaine Webinar on Cement MACT March 30, 2011 Topics Covered Overview of Portland Cement MACT Mercury monitoring on cement kilns PM CEMS
More informationOnline Infrared Flue Gas Analyzer Gasboard 3000
Online Infrared Flue Gas Analyzer Gasboard 3000 O 2 CO CO 2 SO 2 NO NO x Measurement Methods Proprietary Infrared NDIR Detectors - Micro-flow in ppm range: CO, NO, SO2 - Dual beam in % volume ranges: CO2
More informationMLT 2 Multi-Component Gas Analyzer
Product Data Sheet PDS 103-6582.A01 December, 2006 MLT 2 MLT 2 Multi-Component Gas Analyzer APPLICATIONS Chemical process analysis and control Metallurgical process gas monitoring Furnace atmosphere measurements
More informationContinous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden
Continous Emission Monitoring: Methods, Regulations and QA/QC Anders Arvidsson, Opsis AB, Sweden OPSIS? OPSIS is a Swedish company which develops, manufactures and supplies total solutions for Ambient
More informationStack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic
Stack Sampling emissions associated with combustion, velocity and temperature may be much higher than ambient conditions - measure to correct to standard conditions Velocity data determined from pressure
More informationStack Gas Analyzer ENDA-7000 ULTIMATE. Ultimate Reliability. Ultimate. Ultimate. Dependability. Accessibility
Stack Gas Analyzer ENDA-7000 ULTIMATE Ultimate Reliability Ultimate Dependability Ultimate Accessibility ENDA-7000 ULTIMATE Experience HORIBA, the global Single Source Solutions Provider with over 50 years
More informationBiogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas
MRU over 30 years of innovative gas analysis! Biogas analysers Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas Product overview MRU Biogas analysers Whether biogas, landfill and coal mine
More informationAdvanced Spectroscopic Solutions for Fuel Cell Hydrogen Analysis
Advanced Spectroscopic Solutions for Fuel Cell Hydrogen Analysis GASES & CHEMICALS CEMS ENERGY ATMOSPHERIC SEMI & HB LED SYNGAS LAB & LIFE SCIENCE Tiger Optics portfolio of CRDS-based analyzers for analysis
More informationETHYLENE PLANT DRY CRACKED GAS Product Code 54801
SS2100 WATER IN ETHYLENE PLANT DRY CRACKED GAS Product Code 54801 KEY FEATURES Extremely fast analysis time 1 second updates possible Non-contact laser and detector - Reliable Tunable Diode Laser lasts
More informationContinuous Emissions Monitoring (CEMS) Package With NGA 2000 Analyzers
Product Data Sheet PDS 103-101M.A01 June, 2004 GMP 1000M Continuous Emissions Monitoring (CEMS) Package With NGA 2000 Analyzers Packaged approach to measuring up to five gases plus opacity Measurement
More informationOnline data sheet MCS300P HW PROCESS SOLUTIONS
Online data sheet MCS300P HW A B C D E F H I J K L M N O P Q R S T Ordering information Type MCS300P HW Part no. On request The exact device specifications and performance data of the product may deviate
More informationPRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.
PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT CEMS Solution CONTINUOUS, EXTRACTIVE FLUE GAS MONITORING On MCS100E HW, from sampling
More informationFully Extractive Vs. Dilution Extractive CEMS
Fully Extractive Vs. Dilution Extractive CEMS Cemtek Environmental Emissions Seminar & Training Session Santa Ana, CA a technical solution to meet every need CEMTEK Environmental Inc. 3041 S. Orange Ave.
More informationOnline data sheet MCS100E HW-C CEMS SOLUTIONS
Online data sheet MCS100E HW-C A B C D E F H I J K L M N O P Q R S T Ordering information Type MCS100E HW-C Part no. On request The exact device specifications and performance data of the product may deviate
More informationMAX300-AIR PRODUCT NOTE. Ambient Air Monitoring Flare Gas Analysis Industrial Health and Safety. Environmental Mass Spectrometer
MAX300-AIR Environmental Mass Spectrometer PRODUCT NOTE Ambient Air Monitoring Flare Gas Analysis Industrial Health and Safety Introducing the MAX300-AIR Be Safe, Be Clean, Be Compliant Mass spectrometry
More informationModel Product Description and Specifications
Model 900503 Product Description and Specifications Winner of PTEN Innovation Award The Model 900503 Handheld 5 Gases in a 5 Lb Battery Powered Gas Analyzer! Full-featured gas analyzer that you can hold
More informationPRODUCT CONFORMITY CERTIFICATE This is to certify that the
PRODUCT CONFORMITY CERTIFICATE This is to certify that the Babcock & Wilcox Model 2008-1 CEMS (EN 15267-3 Standard) & Babcock & Wilcox Stack Flow Monitor Model 110 manufactured by: Babcock & Wilcox Company
More informationEXM400. Online Gas Analyser. Specialist Of UV Spectroscopy
EXM400 Online Gas Analyser Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Kodda / agence 123rf Page intérieur : Bagiuiani / agence 123rf > EXM400 Online Gas Analyser The
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the MCS 100 FT Manufactured by: SICK AG Rengoldshauser Str. 17 a 88662 Überlingen has been assessed by Sira Certification Service And for the conditions
More informationEnvironmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
More informationCONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited
CONTINUOUS EMISSION MONITORING SYSTEM Copyright 2016 - Adage Automation Pvt Limited WHAT IS CEMS? A continuous emission monitoring system (CEMS) is the total equipment necessary for the determination of
More informationCEM400. Online Gas Analyser. Specialist Of UV Spectroscopy
CEM400 Online Gas Analyser Specialist Of UV Spectroscopy Crédits photos : Tethys Instruments Couverture : Kodda / agence 123rf Page intérieur : Bagiuiani / agence 123rf > CEM400 Online Gas Analyser The
More informationComparison Continuous Emission Monitoring Techniques
PRODUCT DATASHEET: Comparison Continuous Comparison Continuous Emission Monitoring Techniques Overview The requirements for continuous emission monitors has changed significantly over the last 30 years.
More informationTUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities
TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities CEM 2014 May 15-17, 2014 Istanbul, Turkey Peter G. Zemek MultiGas FT-IR Automated HCl CEM Systems MKS Instruments On-Line Product
More informationZP Series of Small, High-sensitivity Infrared Gas Analyzers
ZP Series of Small, High-sensitivity Infrared Gas Analyzers Yuki Masunaga Hideyuki Konishi Kozo Akao ABSTRACT Fuji Electric provides two types of infrared analyzers: small single beam types with a simple
More informationEQUIPMENT APPEARANCE. madur. portable gas analyser
www..com portable gas analyser Photon is a portable analyser using the most current technological developments. It is designed to use mostly infrared sensors, but can also be fitted with further electrochemical
More informationX-Change Gas Sensor Cartridges. PolyGard 2 SC2
X-Change Gas Sensor Cartridges Specifications subject to change without notice. USA 190226 Page 1 of 5 DESCRIPTION The sensor cartridge includes a high performance sensing element (electrochemical for
More informationSG06UNINC-Series BGA/IP55/P Series in Outdoor Designed
SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed BIOGAS measurement and analysis in continuous of methane, carbon dioxide, hydrogen sulphide, oxygen and hydrogen. BGA/INCA as INnovative Case Analyzer
More informationHORIBA Portable Emissions Measurement Systems (PEMS)
HORIBA Portable Emissions Measurement Systems (PEMS) PEMS for Light Duty Vehicle Workshop DAIMLER Stuttgart September 2011 C 2011 HORIBA, Ltd. All rights reserved. Introduction PEMS for Gaseous Measurements
More informationFTIR Analyser BROCHURE
FTIR Analyser BROCHURE JUNHO 2013 ACF-NT Multi-component analyzer system Emission monitoring in combustion processes Analyzer system ACF-NT powerful and cost-effective Are you looking for A reliable analyzer
More informationSAFETY PROCESS INDUSTRY LABORATORY & RESEARCH
SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH Wuhan Cubic Optoelectronics Co.,Ltd ADD:Fenghuang No.3 Road, Fenghuang Industrial Park,Eastlake Hi-tech Development Zone, Wuhan, 430205, China TEL:+86-27-81628827
More informationGMS800 FIDOR Total hydrocarbon analyzer. Gas Analyzers
Product Information GMS800 FIDOR Total hydrocarbon analyzer Continuous monitoring of hydrocarbon emissions Gas Analyzers Solution for continuous hydrocarbon measurements The compact GMS800 FIDOR extractive
More informationSpecial Applications. Special Applications. ENVIRONMENTAL MONITORING. EPA Instrumental Test Methods as Defined by 40 CFR Part 60
EPA Instrumental Test Methods EPA Instrumental Test Methods as Defined by 40 CFR Part 60 # EPA Method Test Method Determines Components Tested Zero Gas* 3A* O 2 % & CO 2 % O 2 % &/or CO 2 % in N 2 or mixtures
More information8 stream capability with dual mode (H 2 S & total Sulphur)
The model 902 H 2 S / Total Sulphur analyzer from Galvanic Applied Sciences Inc. is designed to measure H 2 S in gaseous streams. The 902 detection system is based on the lead acetate tape method. With
More informationMRU FOR PROFESSIONAL MEASUREMENTS
MRU sustainable analysing technology for more than 30 years! MRU FOR PROFESSIONAL MEASUREMENTS PRODUCT OVERVIEW MRU GMBH MRU is a globally acting, successful German manufacturer of high-quality and long-lasting
More informationACX Analyzer systems for emission monitoring, cement applications and process measurement
Data sheet 10/23-8.80 EN Rev. 6 ACX Analyzer systems for emission monitoring, cement applications and process measurement Measurement made easy Applications: Emission monitoring using performance-tested
More informationMAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer
MAX300-RTG Industrial Process Mass Spectrometer PRODUCT NOTE Real-Time Gas Analysis Process Automation and Control Product Quality Analysis www.extrel.com Introducing the MAX300-RTG Optimize Your Manufacturing
More informationGAS 3050P NDIR FLUE GAS
Portable gas analyser GAS 3050P NDIR FLUE GAS Industrial flue gas analysis Powerful, robust and transportable on any industrial site, the GAS 3050P NDIR FLUE GAS analyser offers the same performances as
More informationABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR
White paper WP/ANALYTICAL/002 EN ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field
More informationModel Product Description and Specifications
Model 900403 Product Description and Specifications Winner of PTEN Innovation Award The Model 900403 Handheld All 4 Gases in a 5 Lb Battery Powered Gas Analyzer! Full-featured gas analyzer that you can
More informationONLINE TOC ANALYZER B-Series
ONLINE TOC ANALYZER B-Series Features of Online TOC Analyzers Unique, Patented Two Zone Furnace Design Having two temperature zones assure complete combustion of carbon and nitrogen containing compounds
More informationCombustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins
Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins Agenda Introduction Combustion Theory / Practical Benefits
More information// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.
Configuration: XPLORER with ARCHIE and GLS* // XPLORER-NS Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. TE Instruments has developed the XPLORER-NS, a Total Nitrogen and
More informationControlling NOx and other Engine Emissions
Controlling NOx and other Engine Emissions Extensive Emissions Control Experience in Stationary Diesel and Natural Gas Engines Distributed Power Generation Cogeneration Plants (CHP) Gas Compression & Transmission
More informationMeasuring moisture in ultra-high-purity gases
Measuring moisture in ultra-high-purity gases Many applications require very high purity, inert gases to blanket or produce protective atmospheres. Moisture is the most common contaminant that needs to
More informationTechnical Note TN-114 rev 16 wy/wh.11-04
Sensor Specifications And Cross-Sensitivities Technical Note TN-114 Note: All performance specifications are subject to change without notice and are based upon conditions at 68 o F (20 o C), 50% relative
More informationSEMI-CONTINUOUS EMISSION MONITORING SYSTEM
Page 1 Certified accding to DIN EN 50379-1 and 50379-2 Complying with USEPA methods CTM-030 and CTM-034 Suitable f semi-continuous emission and control measurements at all industrial combustions sources
More informationTHIS IS A REAL-TIME MACHINE. duvastechnologies.com
THIS IS A REAL-TIME MACHINE duvastechnologies.com LATER IS TOO LATE Let s look at Benzene! Benzene is a highly flammable liquid, which occurs naturally in crude oil, natural gas, some ground waters and
More informationEGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians
Data 924-2 7/12/05 EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians Features Complete sample-conditioning
More informationON-LINE OIL TRACE MONITOR
Applications Monitoring of oil separators on drilling platforms and ships Produced water monitoring Detection of oil leakage into cooling water Detection of oil in condensate and boiler feed water Monitoring
More informationPORTABLE FLUE GAS ANALYZER
PORTABLE FLUE GAS ANALYZER SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH What is Flue Gas? Flue Gas Flue gas or Exhaust gas is emitted as a result of the combustion of fuels such as natural gas, gasoline/petrol,
More informationOnline data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS
Online data sheet MAC800 A B C D E F H I J K L M N O P Q R S T 15267 14181 certified certified Ordering information Type MAC800 Part no. On request The exact device specifications and performance data
More informationRESP_IRR_20 P Package
15x15 Respiratory Irritant Sensor 20 ppm P Package 110-901 DESCRIPTION SPEC Sensors RESP_IRR_20 is a Screen Printed ElectroChemical sensor component specifically designed for the broad detection of respiratory
More informationBiogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas
MRU over 30 years of innovative gas analysis! Biogas analysers Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas Product overview MRU Biogas analysers Whether biogas, landfill and coal mine
More information( ppm ) ( ppm ) ( ppm ) History :46:43
Industrial Portable Infrared Analyser Series GAS 3000P NDIR FLUE GAS Up to 5 gases : NO/NO(X) - SO2 - CO - CO2 - O2 Accuracy and linearity : conform to EN 15267-3 Reference methods (SRM) : CO (EN 15058
More informationPortable combustion and emissions analysers
Emissions & calibration instruments Portable combustion and emissions analysers A full range of accurate, robust and versatile portable analysers for industrial measurements RASI 800 MCERTS certified,
More informationGAA330-M Emission monitoring system for marine applications
Data sheet DS/GAA330--EN Rev. A GAA330- Emission monitoring system for marine applications easurement made easy We are on your wavelength Continuous measurement of SO2, CO2 and NOx (option) with a single
More informationTELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700
TELEDYNE ANALYTICAL INSTRUMENTS SERIES 6700 UV / Heated Persulfate Method Ozone / Hydroxyl Radical Method Combustion Method Ultrapure Method The Series 6700 covers a complete range of Total Organic Carbon
More information// XPLORER-NS. Total Nitrogen and Sulfur Analyzer
// XPLORER-NS Total Nitrogen and Sulfur Analyzer Configuration: XPLORER with ARCHIE The XPLORER-NS was developed as a total nitrogen/total n/to tota tal sulfur ur combustion analyzer, alyz offering fast,
More information// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.
// XPLORER-NS Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. TE Instruments has developed the Xplorer-NS, a Total Nitrogen and Total Sulfur combustion analyzer, offering
More informationQuickTOC condensate. Online TOC for steam and condensate circuits. Analysing hot samples accurately. Precise. Fast. Reliable.
Online TOC for steam and condensate circuits. Analysing hot samples accurately. Precise. Fast. Reliable. TOC-ANALYSIS 2 LAR Process Analysers AG The measurement system for Hot water. Organic loads in hot
More informationAnalysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC
Analysis systems Analysis system for CO, Nox, O2, T Conditioned analysis system for the CO-NOx, O2, Temperature measure in flue gas methane boiler Composed of: Zirconia oxygen analyzer CO and NO NDIR infrared
More informationAmbient Air Quality Monitoring
Ambient Air Quality Monitoring Ambient Air Quality Division Air Quality and Noise Management Bureau Pollution Control Department 7/31/2012 2:09 PM 1 Carbon Monoxide (CO) Nitrogen Dioxide (NO 2 ) Ozone
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the PG-350E Multi-component Gas Analyser Manufactured by: Horiba Europe GmbH Julius Kronenberg Straße 9 42799 Leichlingen Germany Has been assessed
More informationUV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-
ON LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, 38240 MEYLAN -FRANCE- TEL : +33 4 76 41 86 39 - FAX : +33 4 76 41 92 27 MAIL : SALES@TETHYS-INSTRUMENTS.COM - WEB : WWW.TETHYS-INSTRUMENTS.COM
More informationGAS ANALYZERS. Digital Manometer
GAS ANALYZERS Digital Manometer 5 Gas Handheld AmPro 2000 O2, CO, NO + NO2 and SO2 or H2S or High CO THE MOST POWERFUL HANDHELD MULTIGAS ANALYZER FOR INDUSTRIAL COMBUSTIONS, EMISSION AND PROCESS MONITORING
More informationWEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month
WEATHER MONITORING ELE Weather Sensors 411 E 215 pw 646 pm Wide ranging expandable air monitoring system, particularly suitable for ambient air analysis Includes sensors for: Wind speed Wind direction
More informationTRACE ANALYTICAL. ta7000 Series UHP Gas Purity Monitors At the critical link in your manufacturing process. Features /Benefits
PROCESS INSTRUMENTS ta7000 Series UHP Gas Purity Monitors At the critical link in your manufacturing process Features /Benefits ta7000 sets the new standard for UHP trace gas monitoring: Highest sensitivity
More informationThermal/Catalytic Oxidizer Model HGTO 500 HD
Thermal/Catalytic Oxidizer Model HGTO 500 HD The model HGTO 500 HD oxidizer is a fuel gas fired thermal oxidizer designed to treat chlorinated, fluorinated, as well as non-halogenated hydrocarbons. The
More informationStandard Continuous Emissions Monitoring System (CEMS)
Scan for more information on CEMS Specification Sheet Continuous Emissions Monitoring System (CEMS) Photo may not represent the actual system supplied. www.usa.siemens.com/cems-std Overview The CEMS is
More informationSensor unit MC2 for toxic gases and oxygen with analog output
Page 1 July 2016-2 Exchangeable sensor unit including digital value processing, temperature compensation and self control for the continuous monitoring of the ambient air. The sensor unit MC2 houses a
More informationPortable Emission Analyzer System
Committing to the future! testo 350-S 350-XL Portable Emission Analyzer System For Compliance, Tuning, and Maintenance The Testing Solution for Your Combustion Application O2 Wireless Bluetooth 2.0 CO
More informationFGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications
Applications An ex situ zirconium oxide analyzer for excess oxygen measurement in dirty, rugged combustion applications such as: Boilers: all fuels and all types, including marine, recover, and utility
More informationCalibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors
Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors KEY FEATURES and BENEFITS Etensive range of standard and custom mitures Blended
More informationMonitoring cement plant stack emissions using FTIR
ABB MEASUREMENT & ANALYTICS WHITE PAPER Monitoring cement plant stack emissions using FTIR ABB FTIR CEMS analyzer successfully monitors cement plant stack emissions in extensive field study Measurement
More informationRENA Pro Ozone Systems A SERIES OF STATE-OF-THE-ART SYSTEMS FOR AIR AND WATER TREATMENT
RENA Pro Ozone Systems A SERIES OF STATE-OF-THE-ART SYSTEMS FOR AIR AND WATER TREATMENT THE RENA PRO SERIES DISTINGUISHING FEATURE An oxygen-fed ozone system built with premium components perfectly integrated
More informationAIR TREATMENT BREATHING AIR PURIFIERS. DBS Series
AIR TREATMENT BREATHING AIR PURIFIERS DBS Series Optimal Performance and Operation The DBS series breathing air purifier from Gardner Denver will provide the clean, dry air necessary to keep your workers
More informationTrace PRODUCT NOTE
VeraSpec Trace www.extrel.com PRODUCT NOTE VeraSpec Trace The VeraSpec Trace DS is the dual-source model with both an API and Extrel s decidedly capable closed source EI ionizer with a capillary inlet
More informationAir Quality (VOC) Transmitters for Duct Mounting. Features. Ordering QDT QDT S QDT D
Features Used to determine the air quality, based on a mixed gas sensor (VOC sensor) To measure the air quality in offices, hotels, meeting rooms, convention centres, schools, airports, apartments, stores,
More informationTitle: Standard Operating Procedure for Measurement of Ozone in Ambient Air by Ultraviolet (UV) Photometry
Procedure No: SOP-022 Revision No: 1.1 January 27, 2011 Page No.: 1 of 8 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality
More informationState of the Art (SOTA) Manual for Stationary Gas Turbines
State of the Art (SOTA) Manual for Stationary Gas Turbines Original Date: July 1997 Revision Date: November 1999 State of New Jersey Department of Environmental Protection Air Quality Permitting Program
More informationGAS CHROMATOGRAPH FOR MULTIPLE IMPURITIES
2 GAS CHROMATOGRAPH FOR MULTIPLE IMPURITIES With its plug and play philosophy, offering more features than never LDetek push further the possibilities with its new chromatograph system. It provides an
More informationFor Safe and Delicious Water
RESIDUAL CHLORINE ANALYZER 400G NON-REAGENT FREE CHLORINE ANALYZER FC400G 400G RESIDUAL CHLORINE ANALYZER FC400G NON-REAGENT FREE CHLORINE ANALYZER Bulletin 12F01A01-01E www.yokogawa.com/an/ For Safe and
More informationIsco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation
Isco EZ TOC Continuous on-line TOC/TC measurement using low-temperature oxidation Easy Programming High Efficiency UV Reactor Enhanced NDIR Detector Flexible Four-Motor Pump System Advanced Dual Calibration
More informationSCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases
SCOTTY Brand Transportables Convenient, Cost-Effective Calibration Gases Now with products engineered expressly for Laboratory and Industrial Hygiene and Safety Applications. SCOTTY products are easy to
More informationSENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES
SENSOR SPECIFICATIONS AND CROSS-SENSITIVITIES Disclaimer: Technical Note TN-114 presents specifications, cross-sensitivities, and calibration information on select RAE Systems sensors. All specifications
More informationSensor Specifications and CroSS- Sensitivities
Sensor Specifications and CroSS- Sensitivities Disclaimer: Technical Note TN-114 presents specifications, cross-sensitivities, and calibration information on select RAE Systems sensors. All specifications
More informationAIR TREATMENT BREATHING AIR PURIFIERS. DBS Series
AIR TREATMENT BREATHING AIR PURIFIERS DBS Series Optimal Performance and Operation The DBS series breathing air purifier from Gardner Denver will provide the clean, dry air necessary to keep your workers
More information