LSA 53.2 Low Voltage Alternator - 4 pole

Size: px
Start display at page:

Download "LSA 53.2 Low Voltage Alternator - 4 pole"

Transcription

1 LSA 53.2 Low Voltage Alternator - 4 pole 400V - 50 Hz / 480V - 60 Hz Electrical and mechanical data

2 Specially adapted to applications The LSA 53.2 alternators are designed to be suitable for typical generator applications, such as: prime power generation, cogeneration, marine applications, rental, telecommunications, data center, emergency genset, etc. Compliant with international standards These alternators conform to the main international standards and regulations: - IEC 60034, NEMA MG , ISO , - CSA C22.2 n , marine regulations, UL are available as an option. They can be integrated into a CE marked generator. These alternators are designed, manufactured and marketed in an ISO 9001 and ISO environment. Top of the range electrical performance Class H insulation Standard 6-wire winding, 2/3 pitch Each model is proposed for two frequencies: - Voltage range 50 Hz: 380V - 400V - 415V V - Voltage range 60 Hz: 380V - 416V - 440V - 480V High efficiency and motor starting capacity Other voltages are possible with optional adapted windings: - 50 Hz : 440V (no. 7S), 500V (no. 9S), 600V (no. 22S or 23S), 690V (no. 10S or 52S) - 60 Hz : 380V and 416V (no. 8S), 600V (no. 9S) 690V Excitation and regulation system suited to the application These alternators can be supplied with AREP + PMI or PMG excitation system, according to the alternator specification. Standard excitation system is AREP with D 510C A.V.R. Volage regulator Excitation system AREP + PMI PMG Current transformer for paralleling Mains paralleling Regulation options 3-phase sensing 3-phase sensing for mains paralleling unbalanced Remote voltage potentiometer D510C Std Option C.T. included included contact factory Option Protection system suited to the environment These alternators are IP 23 Standard winding protection for clean environments with relative humidity 95 % Options: Filters on air inlet: derating 5% Filters on air inlet and air outlet (IP 44): derating 1 Winding protections for harsh environments and relative humidity greater than 95% Space heaters Protection or metering CTs Thermal protection for stator windings and/or bearings (PT100) Reinforced mechanical structure using finite element modelling Compact and rigid assembly to better withstand generator vibrations Steel frame Cast iron flanges and shields Twin-bearing and single-bearing versions designed to be suitable for engines on the market Half-key balancing Regreasable bearings Clockwise rotation in standard Accessible terminal box proportioned for optional equipment Easy access to the voltage regulator and to the connections Possible inclusion of accessories for paralleling, protection and measurement 2 Electric Power Generation

3 General characteristics Insulation class H Excitation system AREP + PMI Winding pitch 2/3 (n 6S) AVR type D 510C Number of wires 6 Voltage regulation (*) ± 0.5 % Protection IP 23 Short-circuit current 30 (3 IN) : 10s Altitude 1000 m Total Harmonic Distortion THD (**) in no-load: < 4 % Overspeed 2250 R.P.M. Waveform: NEMA = TIF (**) < 50 Air flow 2.5 m 3 /s (50 Hz) m 3 /s (60 Hz) Waveform: I.E.C. = THF (**) < 2 % (*) steady state (**) between phases Ratings 50 Hz R.P.M. kva / kw - P.F. = 0.8 Duty/T C Continuous duty/40 C Continuous duty/40 C Stand-by/40 C Stand-by/27 C Class/T K H/125 K F/105 K H/150 K H/163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 380V 400V 415V 440V 380V 400V 415V 440V 380V 400V 415V 440V 380V 400V 415V 440V LSA 53.2 M7 kva kw LSA 53.2 M9 kva kw LSA 53.2 M12 kva kw Ratings 60 Hz R.P.M. kva / kw - P.F. = 0.8 Duty/T C Continuous duty/40 C Continuous duty/40 C Stand-by/40 C Stand-by/27 C Class/T K H/125 K F/105 K H/150 K H/163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 380V 416V 440V 480V 380V 416V 440V 480V 380V 416V 440V 480V 380V 416V 440V 480V LSA 53.2 M7 kva kw LSA 53.2 M9 kva kw LSA 53.2 M12 kva kw Electric Power Generation 3

4 Efficiencies 400V - 50 Hz ( P.F.: 1) (... P.F.: 0.8) LSA 53.2 M7 LSA 53.2 M % 5 75% % 5 75% 10 Load - % kwe Load - % kwe LSA 53.2 M % 5 75% 10 Load - % kwe Reactances (%). Time constants (ms) - Class H / 400V 53.2 M M M12 Kcc Short-circuit ratio Xd Direct-axis synchronous reactance unsaturated Xq Quadrature-axis synchronous reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated X0 Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H / 400V data io (A) No-load excitation current ic (A) On-load excitation current uc (V) On-load excitation voltage kw No-load losses kw Heat dissipation Electric Power Generation

5 Transient voltage variation at load inrush: 400V - 50 Hz LSA kva at P.F. = 0.8 LSA kva at P.F. = Voltage dip 1 2 Voltage dip 1 2 M7 M9 M12 5 M7 M9 M12 LSA kva at P.F. = Voltage dip M7 M9 M12 Transient voltage variation at load rejection: 400V - 50 Hz LSA kva at P.F. = 0.8 M7 M9 M12 Voltage rise Electric Power Generation 5

6 Efficiencies 480V - 60 Hz ( P.F.: 1) (... P.F.: 0.8) LSA 53.2 M7 LSA 53.2 M % 5 75% 10 Load - % kwe % 5 75% 10 Load - % kwe LSA 53.2 M % 5 75% 10 Load - % kwe Reactances (%). Time constants (ms) - Class H / 480V 53.2 M M M12 Kcc Short-circuit ratio Xd Direct-axis synchronous reactance unsaturated Xq Quadrature-axis synchronous reactance unsaturated T do No-load transient time constant X d Direct-axis transient reactance saturated T d Short-circuit transient time constant X d Direct-axis subtransient reactance saturated T d Subtransient time constant X q Quadrature-axis subtransient reactance saturated X0 Zero sequence reactance unsaturated X2 Negative sequence reactance saturated Ta Armature time constant Other class H / 480V data io (A) No-load excitation current ic (A) On-load excitation current uc (V) On-load excitation voltage kw No-load losses kw Heat dissipation Electric Power Generation

7 Transient voltage variation at load inrush: 480V - 60 Hz LSA kva at P.F. = 0.8 LSA kva at P.F. = Voltage dip 1 2 Voltage dip 1 2 M7 M9 M12 5 M7 M9 M12 LSA kva at P.F. = Voltage dip M7 M9 M12 Transient voltage variation at load rejection: 480V - 60 Hz LSA kva at P.F. = 0.8 Voltage rise 2 1 M7 M9 M Electric Power Generation 7

8 Short-circuit curves at rated speed (star connection Y) 12 Isc (short-circuit current /In) LSA 53.2 M7 Short-circuit at alternator terminals Time (seconds) 12 Isc (short-circuit current /In) LSA 53.2 M9 Short-circuit at alternator terminals Time (seconds) 8 Electric Power Generation

9 12 Isc (short-circuit current /In) LSA 53.2 M12 Short-circuit at alternator terminals Time (seconds) Symetrical phase to neutral short-circuit Symetrical two phase short-circuit Symetrical three phase short-circuit Heat damage curve limit Electric Power Generation 9

10 Single bearing dimensions 1115 Xg L 676 Auxiliary cable Cable output U1-V1-W1 Ø 1040 f 8 Ø Ø f 7 Ø 150 m6 Ø DIA,12 eq. sp. holes on P.C.D. 14 DIA,16 eq. sp. holes on P.C.D. 920x Ø AIR OUTLET x Ø 14.5 (dowell pin) Dimensions (mm) and weight Coupling Type L Xg Weight (kg) Flange S.A.E LSA 53.2 M Flex plate S.A.E. 21 X LSA 53.2 M Flex plate S.A.E. 18 X X LSA 53.2 M Flange (mm) Flex plate (mm) S.A.E. N M XBG S S.A.E. BX U X Y AH Torsional analysis data Xr J1 J2 J3 k1 k2 k3 Ø 220 Ø 240 Ø 250 Ø 234 Ø 180 Ø 170 Ø 150 Ø 120 Ø x M27x2 (jacking screw) 220 AIR INLET 4 x Ø 33 (fixing) 500 mini (wall) D drawing files available - Do not hesitate to contact us. FAN MAGNET WHEEL EXCITER Lr Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg) Type Xg Lr M LSA 53.2 M LSA 53.2 M LSA 53.2 M Torsional rigidity [Nm/rad] (kg.m 2 ) k1 k2 k3 J1 J2 J E E E E E E E E E NOTE: Dimensions are for information only and may be subject to modifications. Contractual 2D drawings and 3D drawing files are available and can be downloaded from the site: The torsional analysis of the transmission is the responsability of genset manufacturer. 10 Electric Power Generation

11 Two bearing dimensions Xg LB L Auxiliary cable M12,16 eq. sp. holes on P.C.D Cable output U1-V1-W1 670 Ø 880 Ø f8 Ø 150 m6 Ø1006 Ø x M30x58 Rotation AIR OUTLET 7 4 x Ø 14.5 (dowell pin) 4 x M27x2 (jacking screw) AIR INLET 4 x Ø 33 (fixing) 500 mini (wall) Dimensions (mm) and weight Type L LB Xg Weight (kg) LSA 53.2 M LSA 53.2 M LSA 53.2 M D drawing files available - Do not hesitate to contact us. Torsional analysis data Xr J1 J2 J3 k1 k2 k3 Ø 150 Ø 160 Ø 175 Ø 245 Ø 310 Ø 289 Ø 190 Ø 170 Ø 160 Ø 140 Ø FAN MAGNET WHEEL EXCITER Lr Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg) Type Xr Lr M LSA 53.2 M LSA 53.2 M LSA 53.2 M Torsional rigidity [Nm/rad] (kg.m 2 ) k1 k2 k3 J1 J2 J E E E E E E E E E NOTE: Dimensions are for information only and may be subject to modifications. Contractual 2D drawings and 3D drawing files are available and can be downloaded from the site: The torsional analysis of the transmission is the responsability of genset manufacturer. Electric Power Generation 11

12 Linkedin.com/company/Leroy-Somer Twitter.com/Leroy_Somer_en Facebook.com/LeroySomer.Nidec.en YouTube.com/LeroySomerOfficiel Nidec The information contained in this brochure is for guidance only and does not form part of any contract. The accuracy cannot be guaranteed as Nidec have an ongoing process of development and reserve the right to change the specification of their products without notice. Moteurs Leroy-Somer SAS. Siège : Bd Marcellin Leroy, CS 10015, Angoulême Cedex 9, France. Capital social : , RCS Angoulême en / d

LSA 51.2 Low Voltage Alternators - 4 pole

LSA 51.2 Low Voltage Alternators - 4 pole LSA 1.2 Low Voltage Alternators - 4 pole 186 to 2 kva - Hz / 223 to 3 kva - 6 Hz Electrical and mechanical data Specially adapted to applications The LSA 1.2 alternator is designed to be suitable for typical

More information

LSA 47.2 Low Voltage Alternators - 4 pole

LSA 47.2 Low Voltage Alternators - 4 pole LSA 47.2 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Electrical and mechanical data LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Specially adapted to applications The LSA 47.2 alternator is designed to be

More information

LSA 42.3 Low Voltage Alternators - 4 pole

LSA 42.3 Low Voltage Alternators - 4 pole LSA 42.3 Low Voltage Alternators - 4 pole 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 42.3 alternator is designed to be suitable for

More information

Low Voltage Alternators - 4 pole LSA 46.2

Low Voltage Alternators - 4 pole LSA 46.2 LSA 46.2 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Electrical and mechanical data LSA 46.2-18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Specially adapted to applications The LSA 46.2 alternator is designed

More information

Low Voltage Alternators - 4 pole LSA 46.3

Low Voltage Alternators - 4 pole LSA 46.3 LSA 46.3 180 to 365 kva - 50 Hz / 225 to 435 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 46.3 alternator is designed to be suitable for typical generator applications,

More information

3867 en / a

3867 en / a 3867 en - 9.24 / a Alternators LSA 49.1-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 49.1 alternator is designed to be suitable for typical generator applications, such

More information

3867 en / f. Alternators. LSA Pole Electrical and mechanical data

3867 en / f. Alternators. LSA Pole Electrical and mechanical data 3867 en - 21.4 / f 66... 1 kva - Hz 7... 12 kva - 6 Hz Alternators LSA 49.1-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 49.1 alternator is designed to be suitable for

More information

Low Voltage alternators - 4 pole LSA 42.3

Low Voltage alternators - 4 pole LSA 42.3 Low Voltage alternators - 4 pole LSA 42.3 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data 42en - 12.02 / c SPECIALLY ADAPTED TO APPLICATIONS The LSA 42.3 alternator is designed

More information

3820 en / c

3820 en / c 38 en -.6 / c Alternators LSA 44.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 44.2 alternator is designed to be suitable for typical generator applications, such as:

More information

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2 Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2 5 to 135 kva Electrical and mechanical data 3542 en - 12.08 / f LSA 43.2 / 44.2-4 Pole SPECIALLY ADAPTED FOR SINGLE PHASE Dedicated single

More information

3363 en / e

3363 en / e 3363 en - 03.2005 / e alternators 4 Pole range : 5-2700 kva General features and ratings ALTERNATORS Summary Page 1 - RATING DEFINITION... 3 2 - INSULATION CLASS AND TEMPERATURE RISE... 3 3 - DERATING...

More information

LSA Rating Table Low Voltage Alternators - 4 pole

LSA Rating Table Low Voltage Alternators - 4 pole LSA Rating Table Low Voltage Alternators - 10 to 3300 kva - 50 Hz / 12.5 to 3900 kva - 60 Hz General features and ratings Summary 1 - RATING DEFINITION... 3 2 - INSULATION CLASS AND TEMPERATURE RISE...

More information

ALTERNATOR. LSA 36 - single-phase to 11.5 kva

ALTERNATOR. LSA 36 - single-phase to 11.5 kva 3692 en - 2009.07 / f ALTERNATOR LSA 36 - single-phase - 3.5 to 11.5 kva LSA 36 ALTERNATOR Developed using special modelling software to give optimised electrical performance Designed to supply power to

More information

3456 en / c. 1 to 20 MW Land and offshore applications

3456 en / c. 1 to 20 MW Land and offshore applications 3456 en - 12.2005 / c 1 to 20 MW Land and offshore applications POWER ALTERNATORS Generating Progress Gas or steam turbine application There is currently an enormous increase in energy requirements throughout

More information

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame FLSES 3-phase induction motors with cast iron frame INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems and the world leader in industrial

More information

Environmental Product Declaration PLSES. 3-phase induction ODP motors

Environmental Product Declaration PLSES. 3-phase induction ODP motors PLSES 3-phase induction ODP motors INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems and the world leader in industrial alternators.

More information

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame Product Environnemental Profile LSES 3-phase induction motors with aluminium frame INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems

More information

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Attachment 2 Transmission Provider: Bluestem Electric Cooperative, Inc. Designated Contact Person: Kevin Heptig Address: P.O. Box 5, Wamego, Kansas

More information

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Preface: This Facility Connection Standard applies to any connection to Westar Energy's

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8 Cogeneration Content Cogeneration Content The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8 Inspired solutions 10 No compromise on

More information

Dated: April 16, 2002

Dated: April 16, 2002 Central Hudson Gas & Electric Corporation (CHG&E) Application Process for Distributed Generators of Greater than 300 kva Connected in Parallel with the CHG&E Electrical Delivery System Dated: April 16,

More information

Interconnection Application

Interconnection Application Interconnection Application Persons interested in applying for the interconnection of a distributed energy resource to the Utility s distribution system through the Fast Track or Study Processes are to

More information

EC medium pressure axial fans.

EC medium pressure axial fans. EC medium pressure axial fans. The efficient system solution. The engineer s choice GreenTech EC technology in a new dimension. Thanks to these new new axial axial fans, fans, our our highly highly efficient

More information

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information /2 Orientation /2 Overview /3 Benefits /3 Application /3 Technical specifications /5 More information /6 Type approved standard motors up to frame size 315 L /6 Overview /7 Type approved explosion-proof

More information

Zero cross function. DIN track mounting *2. Screw mounting

Zero cross function. DIN track mounting *2. Screw mounting Solid State Contactors for Heaters Three-phase CSM_Three-phase_DS_E_3_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track

More information

EC medium pressure axial fans. The efficient system solution.

EC medium pressure axial fans. The efficient system solution. EC medium pressure axial fans. The efficient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly efficient GreenTech EC technology is now available for

More information

Generation Application Part B: Technical Form

Generation Application Part B: Technical Form Generation Connections Generation Application Part B: Technical Form For all applications with total installed generation capacity greater than 16A per phase (>4). 01 May 2018 How to fill out this application

More information

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION Designated Contact Person: Mike Avant, Engineering Manager Address (for U.S. Mail Deliveries): Garkane Energy 1802 S Highway 89A Kanab, UT 84741 Telephone Number: (435) 644-5-26 E-Mail Address: mike.avant@garkane.com

More information

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers.

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers. N 16461 DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.01 WORK INCLUDED: A. Copper-wound transformer optimized for light loading, meeting US Department of Energy proposed Candidate Standard Level (CSL) 3 efficiency,

More information

Connection of generation plant to distribution networks. Guidance on completing the application form

Connection of generation plant to distribution networks. Guidance on completing the application form Connection of generation plant to distribution networks It is possible to connect almost any generation plant to the distribution network and in order for the connection to meet the requirements of a new

More information

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 CO-GENERTATION POWER PLANT CONCEPT For dimensioning, design

More information

Axial Fans - Basic principles. Expertise, performance, innovation

Axial Fans - Basic principles. Expertise, performance, innovation Axial Fans - Basic principles Expertise, performance, innovation Fans Motors Control electronics Appendix 15 The truly space-saving axial fans from ebm-papst are used to exchange hot and cold air in all

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install Manual Transfer Switches (MTS) and

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

Low and Medium Voltage Motor Repair

Low and Medium Voltage Motor Repair Low and Medium Voltage Motor Repair Service Center (Shop) Selection and Evaluation Guide Why do we repair electric motors? To realize the benefit of added running hours without incurring the higher expense

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: DQKAJ Frequency: 50 Hz Fuel type: Diesel kva rating: 2500 Standby 2000 Prime Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet:

More information

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 60 Hz Diesel 100 Standby 410 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

Unit Coolers SKB. 4 kw 30,5 kw.

Unit Coolers SKB. 4 kw 30,5 kw. Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...

More information

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 50 Hz Diesel 85 Standby 80 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white 3-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A a b c d e f a c (cont d) e (cont d) f (cont'd) Protection Rating

More information

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Generator set data sheet Model: Frequency: Fuel type: kw rating: DGGAE 60 Hz Diesel 200 Standby 180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Exhaust emission data sheet: Exhaust emission

More information

Emissions level: EPA NSPS Stationary Emergency Tier 2

Emissions level: EPA NSPS Stationary Emergency Tier 2 Generator set data sheet Model: DQPAA Frequency: 60 Hz Fuel type: Diesel kw rating: 600 Standby Emissions level: EPA NSPS Stationary Emergency Tier 2 Exhaust emission data sheet: Exhaust emission compliance

More information

Oil & Gas Energy Solutions. Power Generation Expertise for the Oil & Gas Industry

Oil & Gas Energy Solutions. Power Generation Expertise for the Oil & Gas Industry Oil & Gas Energy Solutions Power Generation Epertise for the Oil & Gas Industry www.pssnola.com 1-800-256-4046 Power Solutions for the Oil and Gas Industry Electric Power Generation was built on the eperience

More information

Cannon Trident Connector System

Cannon Trident Connector System These are low installed cost connectors rated for up to 13 A and 250 V ac. They are typically used for circuit board and internal wiring applications. Snap Together connectors facilitate easy assembly

More information

5.2 MW Solar Mobile Power Unit

5.2 MW Solar Mobile Power Unit 5.2 MW Solar Mobile Power Unit Ventilation air intake Ventilation air exhaust Air inlet & silencer Exhaust Silencer Power Control Room & Trailer -13.8 KV switchgear -CO2 fire system -480 VAC MCCC for turbine

More information

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G Specifications ➊ Front of Panel (Operators) Mechanical Ratings Description Plastic (8EP/ES) Metal (8EM/EB) Vibration (assembled to panel) 1 2 Hz, 1.52 mm max./1 G max. Shock and no damage at 1 G Degree

More information

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS SECTION 26 22 13 HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS PART 1 GENERAL 1.1 WORK INCLUDED A. Dry-type, low-voltage, distribution transformers meeting US Department of Energy proposed Candidate Standard

More information

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202-203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300-301 QUANTITY FOR

More information

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Generator set data sheet Model: Frequency: Fuel type: kw rating: DQGAC 60 Hz Diesel 150 Standby 135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Exhaust emission data sheet: Exhaust emission

More information

3. Design of Generation Equipment. 3.1 Turbine (1) Turbine Types Turbines are classified into two types according to their water energy utility:

3. Design of Generation Equipment. 3.1 Turbine (1) Turbine Types Turbines are classified into two types according to their water energy utility: 3. Design of Generation Equipment 3.1 Turbine (1) Turbine Types Turbines are classified into two types according to their water energy utility: Impulse Turbines: all available water energy is converted

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops. OPERATING LIMITS Flow rates up to : m /h Heads up to :, m Max. operating pressure : bar Max. loop temperature : +8 C Max. circulator temperature: C Max. ambient temperature : + C Water hardness (TH) :

More information

aftertreatment operating costs Designed for maximum performance on FULL RANGE OF ATTACHMENTS low pressure gaseous fuel supply

aftertreatment operating costs Designed for maximum performance on FULL RANGE OF ATTACHMENTS low pressure gaseous fuel supply GAS GENERATOR SET NATURAL GAS CONTINUOUS 1660 ekw 2075 kva 60 HZ 1800 RPM 480 VOLTS BENEFITS Image shown may not reflect actual package Caterpillar is leading the power generation marketplace with Power

More information

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw One Stage Heavy Oil Burners RIELLO 40 N SERIES The Riello 40 N series of one stage heavy oil burners, is a complete range of products developed to respond to any request for the use of heavy oil in heating

More information

Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB

Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB SUBMERSIBLE MULTISTAGE PUMPS SB 3 CONTENENTS 50 Hz Page - SPECIFICATIONS SPECIFICATION PUMP 200 SPECIFICATION MOTOR 201 SELCTION CHART TYPE KEY-TYPE PUMP 202 PERFORMANCE CURVE SB 3 15-23-30-45 203 - CONSTRUCTIONS

More information

Orbital welding (welding generators)

Orbital welding (welding generators) Cutting, facing & orbital welding Our new range of AXXAIR welding generators has been designed to facilitate the use and programming of your equipment. Intuitively, you will have access to sophisticated

More information

MODEL 16ASX T/S - SPECIFICATION

MODEL 16ASX T/S - SPECIFICATION MODEL 16ASX T/S - SPECIFICATION 1.0 General Specifications TM There will be furnished one (1) only Grind Hog Model 16ASX T/S Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a

More information

Water headers are made of reinforced plastic and the design of the spray tree ensures uniform water distribution.

Water headers are made of reinforced plastic and the design of the spray tree ensures uniform water distribution. COOLING TOWERS Main features of CT series cooling towers Standard Modural design Towers are constructed of standardized panels fabricated from heavy gauge hot-dip galvanized steel. Final assembly is made

More information

Air Cooler Industry AC-MS Modular Systems

Air Cooler Industry AC-MS Modular Systems Air Cooler Industry AC-MS Modular Systems General The new AC-MS air coolers are specifically designed to meet the needs of electric power generation applications, such as Diesel or gas generators, gas

More information

SBX 1000 In Situ Oxygen Transmitter

SBX 1000 In Situ Oxygen Transmitter Product Data Sheet PDS 106-360.A01 July, 2005 SBX 1000 SBX 1000 In Situ Oxygen Transmitter SBX FEATURES 12-month warranty Electronics mounted to probe saves on installation and material Advanced sensor

More information

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on

15 15A 20 20A 30 30A 40 40A 60 60A VAC VAC VDC 24VAC VAC. 1 Single-phase. SRH VAC Zero cross turn-on Features DIN rail mount or panel mount installation Dielectric strength: 4000 VAC High heat dissipation efficiency with ceramic PCB and integrated heatsink, random turn-on models available Input Indicator

More information

www.eaton.eu\busbars Power Xpert XP2 Aluminium Eaton Power Xpert XP2 is a 1000 Volt totally encased, non-ventilated, low impedance sandwich construction. The range is available from 800A - 5000A with multiple

More information

INSULATION MONITORING RELAIS

INSULATION MONITORING RELAIS October 2010 RELAIS industrial applications for use in medical rooms e l e t t ro n i c a www.contrel.it HRI series GENERAL Devices allow insulation monitoring for IT systems in medical use rooms, as well

More information

Product information. UP-DO Pump Series Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1.

Product information. UP-DO Pump Series Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1. Product information Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1.4581 Description Normal priming centrifugal pumps with a double Mechanical seal Application:

More information

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded.

RadiFit EC centrifugal fans. Compact, efficient, easily upgraded. RadiFit EC centrifugal fans. Compact, efficient, easily upgraded. Fits, saves and makes sense! Our RadiFit range of centrifugal fans with scroll housing and backward curved blades is the new system solution

More information

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT SECTION 23 05 12 GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete

More information

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC

15 15A 20 20A 30 30A 40 40A 60 60A. Load voltage(rated) VAC VAC VDC 24VAC VAC Single phase, Intergrated heatsink type SSR Features Superior di strength : 4,000VAC Improved reliability by maximizing heat protection efficiency with heatsink integrated design and ceramic board Various

More information

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993 IPS-M-EL-136 MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993 This standard specification is reviewed and updated by the relevant technical

More information

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump Pump Specifications 450 Series 1/2 hp Submersible Sump Pump 450_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice. 450-Series Dimensional

More information

MATERIALS AND EQUIPMENT STANDARD FOR SYNCHRONOUS GENERATORS ORIGINAL EDITION JULY 1994

MATERIALS AND EQUIPMENT STANDARD FOR SYNCHRONOUS GENERATORS ORIGINAL EDITION JULY 1994 MATERIALS AND EQUIPMENT STANDARD FOR SYNCHRONOUS GENERATORS ORIGINAL EDITION JULY 1994 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither whole

More information

INdoor MGM 200 Natural Gas - emissions NOx < 500 5%O2. Type Specifications Co-generation Unit with MAN Gas Engine

INdoor MGM 200 Natural Gas - emissions NOx < 500 5%O2. Type Specifications Co-generation Unit with MAN Gas Engine Type Specifications Co-generation Unit with MAN Gas Engine for installation in engine room INdoor MGM 200 Natural Gas - emissions NOx < 500 mg/m3 @ 5%O2 Scope Specifications Technical Data Engine & Generator

More information

FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS

FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS FreezeFree TM Automated Anti-Icing System GENERAL SPECIFICATIONS I. GENERAL All FreezeFree Automated Anti-Icing Systems shall be designed and manufactured by Energy Absorption Systems, Incorporated, of

More information

Product Environmental Profile

Product Environmental Profile LSES 3-phase induction motors with aluminium frame 4592 en - 2016.1 / b INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems and the world

More information

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: Frequency: Fuel type: kva : DQGAH 50 Hz Diesel 1540 1400 1125 Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

Standby rating. Turbocharged and low temperature after-cooled

Standby rating. Turbocharged and low temperature after-cooled Generator set data sheet Model: Frequency: Fuel type: kva : DQGAN 50 Hz Diesel 1400 1275 1025 Emissions level: EPA NSPS Stationary emergency tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

Equipment Specifications Low Voltage. Active Harmonic Filter

Equipment Specifications Low Voltage. Active Harmonic Filter Equipment Specifications Low Voltage Active Harmonic Filter 1.0 General Description This section contains the design standards, general equipment type and configuration, components, product description,

More information

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 203 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE

More information

1540 Prime 1250 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

1540 Prime 1250 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: Frequency: Fuel type: kva : DQGAG 50 Hz Diesel 1700 1540 1250 Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT TITLE DRAG LINK CHAIN FEEDERS Phone: +91 431 2574091/2574046

More information

Problem specification

Problem specification 1 of 6 pages University of Rochester Department of Electrical & Computer Engineering ECE227/427 Take-home Exam due: 4-30-10 You are to work entirely alone on this take-home exam. NO COLLABORATION IS ALLOWED.

More information

1 29SEP03 ALL General update with miscellaneous changes in entire document.

1 29SEP03 ALL General update with miscellaneous changes in entire document. REVISION RECORD SECTION 16461 Dry-Type Transformers (600 V and Less) REV DATE PAGE PARA NO. DESCRIPTION APPROVED BY 28SEP01 ALL Initial issue. 1 29SEP03 ALL General update with miscellaneous changes in

More information

MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM

MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM Research Article MEASUREMENTS AND SIMULATION FOR POWER QUALITY OF A WIND FARM 1 S.P. Shukla, 2 Sushil Kumar Address for correspondence 1 Department of Electrical Engineering, Bhilai Institute of Technology,

More information

Power Quality Improvement in Distribution System Using Distribution Static Compensator

Power Quality Improvement in Distribution System Using Distribution Static Compensator Power Quality Improvement in Distribution System Using Distribution Static Compensator Jay Kumar Sharma 1, Om Prakash Mahela 2 and Sunil Agarwal 1 1 Department of Electrical Engineering, Apex Institute

More information

Fixed Demand (Block Demand) The utility company sends a signal to synchronize the start of the Maximum Demand period.

Fixed Demand (Block Demand) The utility company sends a signal to synchronize the start of the Maximum Demand period. Maximum demand control systems M 6 M.6.02 GB Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kw h) Reactive energy consumption

More information

HRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS

HRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS HRI-R22t series GENERAL HRI-R22t series The device has similar characteristics of previous model but it s more cheap and it has less functions. There is measuring signalling and it is able to verify temperature

More information

Energy efficiency of low voltage electrical installations

Energy efficiency of low voltage electrical installations Energy efficiency of low voltage electrical installations One new area within international standards is the integration of requirements for energy efficiency into IEC 60364 (the international standard

More information

Type Type 2000 Transducers. I/P & E/P Transducers

Type Type 2000 Transducers. I/P & E/P Transducers Type 2000 I/P & E/P Description Principle of Operation The Type 2000 I/P and E/P transducers utilize closed-loop pressure feedback-control for precision pressure output and minimized effects of temperature,

More information

Participation in the sale of Energy Efficient Appliances

Participation in the sale of Energy Efficient Appliances Nepal Electricity Authority (A Government of Nepal Undertaking) Invitation of Proposals for Participation in the sale of Energy Efficient Appliances Issued by: Nepal Electricity Authority Energy Efficiency

More information

Accreditation Scope by Certification Test Order

Accreditation Scope by Certification Test Order Organization NEMA MW 1000 NEMA RE-2 Section 4.11 ASTM D149 ASTM D150 ASTM D256 ASTM D257 ASTM D495 ASTM D570 ASTM D635 ASTM D638 ASTM D790 ASTM D882 ASTM D1653 ASTM D1676 ASTM D1822 ASTM D1830 ASTM D1876

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL Customer : Description : EST FAN (Energy Saving Technology Fan) Customer Part No. REV. : Delta Model No. REV. : 02 Sample Issue No. : Sample Issue Date : Nov. 07 2017 PLEASE

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART 204 PERFORMANCE CHART VOX 205 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW

More information

MINIMAL WEIGHT GEISLINGER CARBOTORQ

MINIMAL WEIGHT GEISLINGER CARBOTORQ MINIMAL WEIGHT GEISLINGER CARBOTORQ GEISLINGER CARBOTORQ The Geislinger Carbotorq coupling is a revolutionary solution for elastomer couplings. Its innovative, maintenance-free design provides torsional

More information