1 702-CRC-004-E Page: 1/16 Prepared by: Douglas Ferreira Checked by: Nelson A. Coelho Karen Martins Approved by: Arnaldo Barbulio Filho Approval Date: 23/08/ PURPOSE This document presents the complementary criteria for the Product Certification Rule 700-RC-001 for certification and for maintenance of the license to use of the conformity marking of SBAC, INMETRO and TÜV Rheinland do Brasil Ltda. SBAC - Sistema Brasileiro de Avaliação da Conformidade in which means Conformity Evaluation Brazilian System. 2 APPLICATION FIELD Applicable to all companies that apply for the grant of the license for the use of the Compulsory Conformity Marking on the products: NBR NM-247-3: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V- Part 3: Non-sheathed cables for fixed wiring (IEC , MOD) to grant and maintain the license to use of the conformity marking of SBAC, INMETRO and TÜV Rheinland do Brasil Ltda. NBR 13249: Flexible cables and cords of rated voltages up to and including 450/750V Specification to grant and maintain the license to use of the conformity marking of SBAC, INMETRO and TÜV Rheinland do Brasil Ltda. NBR 7288: Power cables with solid insulation extruded of polyvinyl chloride (PVC) or polyethylene (PE) for rated voltages from 1 kv to 6 kv to grant and maintain the license to use of the conformity marking of SBAC, INMETRO and TÜV Rheinland do Brasil Ltda. ABNT NBR 14898: Flexible cables insulated with ethylene propylene rubber (EPR) for special applications in connecting cords of electric household appliances in rated voltages up to 500V to grant and maintain the license to use of the conformity marking of SBAC, INMETRO and TÜV Rheinland do Brasil Ltda. ABNT NBR 14897: Flexible cables and cords insulated with polyvinyl chloride (PVC) for special applications in connecting cords of electric household appliances in rated voltages up to 500V to grant and maintain the license to use of the conformity marking of SBAC, INMETRO and TÜV Rheinland do Brasil Ltda. ABNT NBR 14633: Flexible cords with insulation extruded of chlorosulfonated polyethylene (CSP) for rated voltages up to and including 300 V Performance requirements - to grant and maintain the license to use of the conformity marking of SBAC, INMETRO and TÜV Rheinland do Brasil Ltda. 3 RESPONSIBILITY The responsibility for the revision of this Complement is from TÜV Rheinland do Brasil Ltda. 4 ACRONYMS AND ABBREVIATIONS The requirements of the clause 4 of the Rule of Certification 700-RC-001 are applicable. 5 DEFINITIONS The requirements of the clause 5 of the Rule of Certification 700-RC-001 are applicable, complemented by those as below. 5.2 License for the Use of the Conformity Marking The requirements of the clause 5.2 are: - The item a) is applicable with the text changed for: Corporate Name, ID Card Number or Registration Business Entry and Main Office Address of the Applicant and of the Manufacturer. Note: The companies located Abroad, with no representative person in Brazil, must present the updated articles of the incorporation registered in the Notary or a certificate from the Notary bearing the same information namely company's name, core business, representation's requirements, shareholders in the origin country; - The item b) is applicable, being the identification of the license, for the use of the Conformity Marking, the number of the certificate. Applicable the date of issue and the valid term; - The item c) is applicable Beyond the established requirements described in the item 5.2, the License must contain

2 Page: 2/16 d) The system of certification is of Model 5, or when it is certification per lot, the system of certification is of Model 7. e) The effected date of the certificate; f) The product description; g) The technical standards applicable to the certified product; h) The grant for the use of the marking (License for the use of the Conformity Marking of TÜV Rheinland do Brasil) The license for the use of the Conformity Marking for Wires, Cables, Cords and Adhesive Tapes is of 2 years. Note: the expiry date can suffer adjustment in order to allow that in the valid term, all the activities supposed to be finished in the period, be concluded. For instance: when the company is already a customer and it has other issued certificates and/or in reason of the planned audits Certification Commission of TÜV (Technical Commission of TÜV): For the voluntary certifications, with or without accreditation scope, within the ambit of this Complement, the Certification Commission is formed by, at least, the representative persons from the professional associations of the manufacturers, consumers and other neutral organizations, all of them with recognized competence Complementary documents Inmetro rule (Portaria) nº 87 from May 20 th, 2003 Inmetro rule (Portaria) nº 85 from May 26 th, 2003 Inmetro rule (Portaria) nº 86 from May 26 th, 2003 Inmetro rule (Portaria) nº 281 from July 19 th, 2007 Inmetro rule (Portaria) nº 282 from July 19 th, 2007 Inmetro rule (Portaria) nº 286 from July 19 th, 2007 Inmetro rule (Portaria) n 231 from September, 28 th, 2006 Inmetro rule (Portaria) nº 268 from June 21 st, electrical devices used in Electrical Installations of Low Voltage up to 1 kv with nominal rated current up to 63A NBR NM-247-1: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V Part 1: General Requirements (IEC , MOD); NBR NM-247-2: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V Part 2: Test methods (IEC , MOD); ABNT ISO/IEC Guide 2:2006 Standardization and related activities general vocabulary; ABNT ISO/IEC Guide 28: Conformity assessment - Guidance on a third-party certification system for products; ABNT ISO/IEC Guide 65: General requirements for bodies operating product certification systems; ABNT ISO/IEC Guide 67: Conformity assessment - Fundamentals of product certification; NBR ISO 9001: Quality Management Systems Requirements; NBR ISO/IEC 17000: Conformity assessment - Vocabulary and general principles; NBR ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories NBR ISO/IEC 17030: Conformity assessment - General requirements for third-party marks of conformity; Law nº 8.078/ Consumer Protection and Defense Code, section IV On Abusive Practices. 6 GENERAL CONDITIONS The requirements of the clause 6 of the Rule of Certification 700-RC-001 are applicable. 7 GRANT CONDITIONS The requirements of the clause 7 of the Rule of Certification RC-001 are applicable.

3 Page: 3/16 8 EVALUATION MECHANISM OF THE CONFORMITY The Evaluation Mechanism of the Conformity is of Certification. The model of the Certification to be used is of the model with type tests, evaluation and approval of the quality system of the manufacturer, surveillance through the audits in the manufacturer and tests on the samples taken from the commerce and in the manufacturer - Model 5. The steps described in the clause 8 of the Rule of Certification RC-001 are applicable, complemented as follow ahead Initial Audit The items checked in the initial audit are the established in the annex A of this Complement Type tests The type tests are the established in the annex B of this Complement Maintenance of the Certification The evaluation of the quality system of the manufacturer is through surveillance audits carried out according to the established in the annex A of this Complement The surveillance tests will be carried out according to the established in the annex B of this Complement Renewal The renewal (certificate s renewal) is carried out when the presentation of the processes to the Technical Commission of TÜV Rheinland do Brasil, with test results and of the surveillance audits. 9 RECOGNITION OF THE ACTIVITIES OF THE CERTIFICATION The requirements of the clause 9 of the Rule of Certification RC-001 are applicable. 10 APPLICANT S OBLIGATIONS (LICENSED COMPANY) The requirements of the clause 10 of the Rule of Certification RC-001 are applicable. 11 CERTIFICATION BODY S OBLIGATIONS The requirements of the clause 11 of the Rule of Certification RC-001 are applicable. 12 EXTENSION OR REDUCTION OF THE CERTIFICATION S SCOPE The requirements of the clause 12 of the Rule of Certification - RC-002 are applicable. 13 APPEAL The requirements of the clause 13 of the Rule of Certification RC-001 are applicable. 14 VALIDITY AND MAINTENANCE OF THE CERTIFICATION The requirements of the clause 14 of the Rule of Certification RC-001 are applicable. 15 COMPLAINTS AND DENUNCIATION The requirements of the clause 15 of the Rule of Certification RC-001 are applicable. 16 UNDUE USE OF THE CERTIFICATION The requirements of the clause 16 of the Rule of Certification RC-001 are applicable. 17 SUSPENSION OF THE CERTIFICATION The requirements of the clause 17 of the Rule of Certification RC-001 are applicable. 18 CANCELLATION OF THE CERTIFICATION The requirements of the clause 18 of the Rule of Certification RC-001 are applicable. 19 RESIGNATION

4 Page: 4/16 The requirements of the clause 19 of the Rule of Certification RC-001 are applicable. 20 VARIATION OF THE REQUIREMENTS OF THE CERTIFICATION The requirements of the clause 20 of the Rule of Certification RC-001 are applicable. 21 REVISION STATUS Date Revision Responsible 23\8\13 Change the number of documents Gabriela Halphen

5 Page: 5/16 ANNEX A EVALUATION OF THE QUALITY CONTROL SYSTEM OF MANUFACTURING A.1 The evaluation, initial and periodic, of the quality control system of manufacturing, will be carried out by TÜV RHEINLAND DO BRASIL. A.2 The evaluation, initial and periodic, of the quality control system of manufacturing must check if the requirements established below, when applicable in the scope of the Quality Management System of the Manufacturer: 1. Control of records - (*) fulfill the item of the Standard 2. Control of production - (*) fulfill the item and Identification and traceability - (*) fulfill the item of the Standard 4. Preservation of product - (*) fulfill the item of the Standard 5. Control of monitoring and measuring equipment - (*) fulfill the item 7.6 of the Standard 6. Monitoring and measurement of product - (*) fulfill the item of the Standard 7. Control of nonconforming product - (*) fulfill the item 8.3 of the Standard 8. Corrective action - (*) fulfill the item of the Standard 9. Preventive action - (*) fulfill the item of the Standard Note: For this evaluation, will be used, as reference, the content presented in the standard NBR ISO 9001: Quality Management System - Requirements. A.3 In the evaluation, initial and periodic, of the quality control system of manufacturing will be checked the correct functioning of the spark tester, as to its effectiveness and as to its calibration in the range of the electrical voltage applied by the manufacturer within the specified conditions by the respective standards. A.4 In the evaluation, initial and periodic, of the quality control system of manufacturing will be checked carried out, by the manufacturer, of the routine tests established in the respective standards and their results. Note: see paragraph B.2.3 for the routine tests. A.5 If the manufacturer has its quality system certified by one SCB (System Certification Body) accredited by Inmetro, according to NBR ISO 9001:2008, TÜV RHEINLAND DO BRASIL will analyze the documentation related to the certification of quality system, assuring that the requirements described above were evaluated focusing the product to be certified. Otherwise, TÜV RHEINLAND DO BRASIL must check the fulfillment of the requirements described in the items A.2, A.3 and A.4. A.6 The periodic evaluation of the quality control system of manufacturing will be carried out, at least, once a semester (6 months) after the grant of the license for the use of the Conformity Marking.

6 Page: 6/16 ANNEX B TESTS AND SAMPLINGS B.1 The tests described in this CRC are established in the specific standards, any amendment, or update in the version of these standards, will be able to use only with the authorization of TÜV Rheinland do Brasil. B.2 General The collect of samples for the tests is carried out by TÜV Rheinland do Brasil. B.2.1 Initial or Certification Tests The certification tests and the respective samplings for each product established in this Complement are defined in the annexes B.3.x.1. In case of prototypes, the manufacturer can collect and forward the necessary samples to the Laboratory and/or TÜV Rheinland do Brasil, in accordance with them, and under responsibility of TÜV Rheinland do Brasil. The approval on the tests does not exempt TÜV Rheinland do Brasil about validating the products after the beginning of the operation of the line of production. B.2.2 Surveillance tests The conduction of the surveillance tests will be carried out by TÜV Rheinland do Brasil, being taken from the commerce (or from the factory s logistics) and from the stock of the manufacturer, alternately. The periodicity of the tests performance will be at each 6 months, after the grant of the license for the use of the Conformity Marking. At the end of the cycle of 04 (four) semesters, the sequence must be restarted. The collected samples must be sent to the laboratory within a term of 15 days after the collect. If these samples are not sent within the established term, the certificates will be able to be suspended. The surveillance tests for the products established in this Complement are established in the annexes B.3.x.2. One section of each conductor class will be collected, 1 and 2, made, and for the conductor classes 4, 5 or 6, just on one unique sample (except for standard NBR 247-3, that have a collect according rule nº 85/2003), of its highest conductor class, preferably. For each surveillance test of one kind of product, will be collected one different section, preferably. The necessary quantity is of 1 unit of logistics, if coil of 100m, or if reel, or length of 30 meters, at minimum. For the vertical burning test, when applicable, the quantity will be established considering the requested/selected section. For the electrical resistivity and copper elongation tests, when applicable, will be carried out on the samples collected in the manufacturing process, after the annealing process of the drawn wire and before of the next process. The necessary quantity is of 10 meters, at minimum. B.2.3 Routine tests The routine tests for the products established in this Complement are, at minimum, the tests of marking checking, construction checking, dimensional checking, conductor electrical resistance at 20ºC, high voltage test, insulation resistance at 20ºC or, when it is not specified, the maximum temperature of operation, and spark test. The tests will be carried out by the manufacturer and must include all the lots (batches) of the made materials and approved for the stock /commerce. The samplings will be as established in the respective standards of the product. B.2.4 Periodical tests The periodical tests are not established, however, we recommend that the following tests be carried out as: mechanical characteristics for insulation and sheath (if exists): tensile strength and elongation at break, before and after ageing, at minimum at each development of new suppliers / raw-materials. B.3 Particularities The tests and samplings for the products established in this Complement are described in B.3.1 to B.3.6.

7 Page: 7/16 B NBR NM 247-3:2002 B Initial tests The initial tests are the type tests established: Packing marking checking; Product marking; Conductor construction; Dimensional checking; Insulation resistance at 20ºC; Oxigen index; Copper electrical resistivity at 20ºC; Pressure at high temperature; Copper elongation; Mechanical characteristics of the insulation; Cold bending/elongation for the insulation; Insulation resistance at 70ºC; Heat shock test; Water absorption test; Vertical burn test; Loss of mass test B a Sampling The necessary quantities for the tests are established in the standard NBR NM and correspond to the highest and to the smaller section of conductors of each conductor class made. B Surveillance tests The following tests must be carried out on each one of the samples: Marking checking; Construction checking; Conductor and insulation dimensionals; Conductor resistance at 20ºC; Insulation resistance at 20 C; Oxigen index. B a Beyond the tests mentioned in the previous item, the tests described as below must be carried out, according to the established periodicity, having as reference the grant of the license for the use of the Conformity Marking. 1º Semester: electrical resistivity, pressure at high temperature, loss of mass test; 2º Semester: mechanical characteristic of the insulation, cold bending/elongation of the insulation, copper elongation; 3º Semester: heat shock, insulation resistance at 70 C; 4º Semester: water absorption, mechanical characteristics of the insulation.

8 Page: 8/16 B NBR 13249:2000, for the insulation in PVC/F and sheath in ST1, as compulsoriness B Initial tests The initial tests are established the type tests: Label marking; Product marking; Conductor construction; Dimensional checking; Separation of cores (for parallel cords); Insulation resistance at 20ºC; Copper electrical resistivity at 20ºC; Pressure at high temperature of the insulation and sheath; Flexing test: (parallel cord from 0,5 to 0,75mm² and flexible cables from 0,75 to 4 mm²) B a Sampling Mechanical characteristics of the insulation and sheath; Cold bending /elongation of the insulation and sheath; Copper elongation; Cold impact (for the sheath in ST1); High voltage on cores; Heat shock; Flame resistance; Water absorption; Insulation resistance at 70ºC. The necessary quantities of the samples for the tests are described in the standard NBR and correspond as indicated in the table. Product Nº of cores Conductor classes Voltage (V) Type tests Flexing test Parallel Flexible Cord 2 4, 5 or x 2,5 2 x 0,5 Twisted Flexible Cord 2 4, 5 or x 2,5 --- Circular Flexible Cable 2 to 5 4, 5 or x 0,75 3 x 0, x 2,5 2 x 0, x 0,75 3 x 0,75 Flat Flexible Cable 2 and 3 4, 5 or x 2,5 3 x 2,5 Note: (1) If the manufacturer does not make any of the cables as indicated, the closest one must be used. (2) The table 1 is applicable to the lowest conductor class among the ones requested by the manufacturer. For the other classes, routine and flexing tests are performed in the sections and constructions established in the table above. (3) If the manufacturer produces 300V and 750V cables, the tests in table 1 are performed at the highest voltage, while the routine and flexing additional tests are performed on the lowest voltage. B Surveillance tests At each semi-annual surveillance, the correct functioning of the spark tester will be checked, as to its effectiveness and as to its calibration in the applied electric voltage range by the manufacturer, according to the conditions specified by the standard NBR Beyond of that, the following tests must be carried out the type tests on each one of the collected samples: Label marking; Product marking; Conductor construction; Dimensional checking; Separation of cores (for the parallel cords); Insulation resistance at 20ºC. B a Beyond the mentioned tests in the previous item, the tests as described below must be carried out, according to the established periodicity. 1º Semester: electrical resistivity, pressure at high temperature, flexing test; 2º Semester: mechanical characteristics of the insulation/sheath, cold bending/elongation, copper elongation, cold impact test (for sheath in ST1); 3º Semester: heat shock test, flame resistance test, high voltage on cores test; and 4º Semester: water absorption, insulation resistance at 70 C, mechanical characteristics of the insulation/sheath.

9 Page: 9/ NBR 7288:1994 B Initial tests The initial tests are the established type tests: Label marking; Product marking; Conductor construction; Dimensional checking; Insulation resistance at 20ºC; Copper electrical resistivity at 20ºC; Pressure at high temperature of the insulation and sheath; Mechanical characteristics of the insulation and sheath; B a Sampling Cold bending/elongation of the insulation and sheath; Cold impact test; Copper elongation test; Long term high voltage test; Flame resistance ** / vertical burning test *; Heat shock test of the insulation and sheath; Water absorption test; Insulation resistance at 70ºC; Non-contamination test. The necessary quantities of the samples for the tests are those as indicated in the table below: Cable type Single core or multiplexed Conductor classes 1, 2, 4, 5 Multicore 2, 4, 5 Initial tests Type On the lowest section of the highest conductor class and on the highest section of the lowest conductor class made. On the lowest section of the highest conductor class and on the highest section of the lowest strand class made Additionals On the lowest section of conductor class 1 or 2 On the lowest section of conductor class 1 or 2 The maximum cable section is of 120mm² to carry out the initial tests, except for the vertical flame test, section 6.1.3(a) of the NBR 7288:1994, where the maximum section is 50mm². B Surveillance tests At each semi-annual surveillance, the correct functioning of the spark tester will be checked, as to its effectiveness and as to its calibration in the applied electric voltage range by the manufacturer, according to the conditions specified by the standard NBR Beyond of that, the following tests must be carried out the type tests on each one of the collected samples: Cable construction checking; Insulation resistance at 20ºC. B a Beyond the mentioned tests in the previous item, the tests as described below must be carried out, according to the established periodicity, having as reference the grant of the license for the use of the Conformity Marking. For the insulation in PVC and sheath in PVC: 1º Semester: conductor electrical resistivity and pressure at high temperature; 2º Semester: mechanical characteristics of the insulation and sheath, cold bending, cold impact test and copper elongation; 3º Semester: long term high voltage test, flame resistance test (in case of PVC compound with no special characteristics of non-propagation of fire) or vertical burn and heat shock test; and 4º Semester: water absorption, insulation resistance at 70ºC and non-contamination test. For the insulation in PVC and sheath in PE/ST3: 1º Semester: conductor electrical resistivity, carbon black content and pressure at the high temperature test; 2º Semester: mechanical characteristics of the insulation and sheath and copper elongation; 3º Semester: long term high voltage and heat shock; and 4º Semester: water absorption, insulation resistance at 70ºC and non-contamination test.

10 Page: 10/16 B.3.4 NBR 14633:2000 B Initial tests The initial tests are the established type tests: Marking checking; Construction (dimensional) checking; Adherence of the insulation on the conductor; Electrical resistance test; Separation of cores; Insulation resistance at 20ºC; Long term high voltage test; Insulation resistance at the maximum temperature of operation; Mechanical characteristics; Flame resistance; Resistance to heat B a Sampling The necessary quantities of the samples for the tests are described in the standard NBR and correspond to the highest and lowest conductor sections of each conductor class made. B Surveillance tests At each semi-annual surveillance, the correct functioning of the spark tester will be checked, as to its effectiveness and as to its calibration in the applied electric voltage range by the manufacturer. Beyond of that, the following tests must be carried out the type tests on each one of the collected samples: Marking checking; Conductor construction checking; Insulation dimensional checking; Adherence of the insulation on the conductor; Separation of the cores; and Insulation resistance at 20ºC. B a Beyond the mentioned tests in the previous item, the tests as described below must be carried out, according to the established periodicity, having as reference the grant of the license for the use of the Conformity Marking. 1º Semester: Resistance to heat; 2º Semester: Tensile strength of the insulation before and after ageing; 3º Semester: Flame resistance and long term high voltage test; and 4º Semester: Insulation resistance at (90ºC or 105ºC).

11 Page: 11/16 B.3.5 NBR 14897:2002 B Initial tests The initial tests are the established type tests: Marking checking; Construction (dimensional) checking; Insulation resistance at 20ºC; Separation of cores (only for parallel cords); Insulation resistance at 105ºC; Mechanical characteristics (insulation and sheath); Non-contamination test; B a Sampling High voltage test on cores; Flexing test; Thermal stability (sheath); Heat shock (insulation and sheath); Cold bending / elongation (insulation and sheath)*; Flame resistance; Pressure test at high temperature (insulation and sheath); Loss of mass test (sheath)*; Cold impact test*. The necessary quantities of the samples for the tests are those as indicated in the table below: Products family Nº of cores Conductor class Rated voltage (V) Type tests Flexing followed by voltage test Parallel Flexible Cord 2 4, 5 or x 2,5 mm² 2 x 0,5 mm² Circular Flexible Cable 2 to 5 4, 5 or x 1,5 mm² 2 x 0,5 mm² Flat Flexible Cable 2 and 3 4, 5 or x 1,5 mm² 2 x 0,5 mm² Note: (1) If the manufacturer does not make anyone of the indicated cables must be used the closest one possible. (2) The table is applicable for the smallest conductor class in the requested scope by the manufacturer. For the other conductor classes of each family are carried out all the tests denominated in the standard as routine tests and flexing test followed by high voltage test denominated as type tests in the standard, on the sections and conductor classes as established in the table above. The tests complement the range of the scope. (3) The insulation will be in polyvinyl chloride of type PVC/EB and the sheath of type PVC/ST10. B Surveillance tests At each semi-annual surveillance, the correct functioning of the spark tester will be checked, as to its effectiveness and as to its calibration in the applied electric voltage range by the manufacturer, in the conditions established by the standard NBR Beyond of that, the following tests must be carried out the type tests on each one of the collected samples: Marking checking; Construction (dimensional) checking; Conductor electrical resistance at 20ºC; Insulation resistance at 20ºC; and Separation of cores (only for parallel cords). B a Beyond the mentioned tests in the previous item, the tests as described below must be carried out, according to the established periodicity, having as reference the grant of the license for the use of the Conformity Marking. 1º Semester: pressure test at high temperature of the insulation/sheath and high voltage test on the cores; 2º Semester: tensile strength of the insulation / sheath before and after ageing and thermal stability of the sheath; cold impact test *; 3º Semester: heat shock test, flame resistance test and flexing test followed by high voltage; loss of mass test (sheath)*; and 4º Semester: non-contamination test and insulation resistance at 105ºC; cold bending/elongation (insulation and sheath)* *Additional requirement, not established in the INMETRO rule, however belonging as part of the standard.

12 Page: 12/16 B.3.6 NBR 14898:2002 B Initial tests The initial tests are those established as type tests: Marking checking; Construction (dimensional) checking; Insulation resistance at 20ºC; Ozone resistance test (insulation); Immersion in oil test (sheath); Flame resistance test; Mechanical characteristics (insulation and B a Sampling sheath); High voltage test on cores; Hot set test (insulation and sheath); Water absorption test (insulation - gravimetric); Insulation resistance at 130ºC; Flexing test; Tensile test after ageing in the air bomb (insulation); and Non-contamination test. The necessary quantities of samples for the tests are those as indicated in the table below: Product Nº of cores Conductor class Voltage (V) Type tests Flexing Circular Flexible Cable 2 to 3 4, 5 or x 1,5 2 x 0,5 Flat Flexible Cable 2 and 3 4, 5 or x 1,5 2 x 0,5 Note: (1) If the manufacturer does not make any of the cables indicated, the closest one section must be used. (2) The table 1 is applicable to the lowest conductor class among the ones requested by the manufacturer. In the other conductor classes routine and flexing tests are performed in the sections and constructions established in the table above. (3) The insulation must be in EPR and the sheath in thermosetting compound ES 130. B Surveillance tests At each semi-annual surveillance, the correct functioning of the spark tester will be checked, as to its effectiveness and as to its calibration in the applied electric voltage range by the manufacturer, in the conditions established by the standard NBR Beyond of that, the following tests must be carried out the type tests on each one of the collected samples: Marking checking; Construction (dimensional) checking; Insulation resistance at 20ºC. B a Beyond the mentioned tests in the previous item, the tests as described below must be carried out, according to the established periodicity, having as reference the grant of the license for the use of the Conformity Marking. 1º Semester: ozone resistance test and insulation resistance at 130ºC; 2º Semester: mechanical characteristics (insulation and sheath); non-contamination test; water absorption (insulation - gravimetric); 3º Semester: flame resistance test, hot set test of the insulation/sheath and flexing test followed by high voltage; 4º Semester: Tensile test after ageing in the air bomb of the insulation/sheath, high voltage test on cores and immersion in oil test.

13 Page: 13/16 ANNEX C ACTIONS AGAINST THE NON-CONFORMITIES C.1 In one initial certification, eventual non-conformities must be corrected before the conclusion of the process. C.2 Identified any non-conformity in anyone of the surveillance tests, this test must repeated on two samples new, counterproof and witness, for the attribute non-conform, not being admitted the identification of any non-conformity. Note: If TÜV Rheinland do Brasil deems suitable and in agreement with the manufacturer, the nonconformity might be confirmed without the execution of the counterproof and witness tests. C.3 When the non-conformity confirmation, TÜV Rheinland do Brasil will suspend immediately the license for the use of the conformity marking, requesting the manufacturer the relevant treatment, with the establishment of the corrective actions and implementation deadlines. Note: If the non-conformity found, does not put at risk the safety of the user, under TÜV Rheinland do Brasil s analysis and responsibility, the manufacturer can not have its license for the use of the conformity marking suspended, since it has assured TÜV Rheinland do Brasil through corrective actions, the correction of the non-conformity on the existing products in the market and the implementation of these actions of the production line.

14 Page: 14/16 ANNEX D CONFORMITY MARKINGS D.1 The Conformity Markings to be applied on the products and packings are as follow: INMETRO and TÜV RHEINLAND a) For product and packing INMETRO and UCIEE a) For product and packing One color b) only on the product b) only on the product c) minimum sizes 35 mm c) minimum sizes 35 mm

15 Page: 15/16 Notes: 1) The INMETRO + TUV marking to be granted for the compulsory scopes whose are included in the annex of the accreditation of TÜV Rheinland do Brasil, related to INMETRO. The INMETRO + UCIEE will be granted only for the customers in which had already the authorization for the use of this marking and for the compulsory scopes whose were included in the annex of the accreditation of TUV Rheinland do Brasil, related to INMETRO, in April, ) The wires, cables and cords that for their dimensions make impossible the clear printing on the product the Conformity Markings of the item a) will be allowed the use of the Markings of the item b). 3) The wires, cables and cords that for their dimensions make impossible the clear printing on the product the marking of TÜV Rheinland do Brasil, will be allowed, as alternative to this marking, the use of the name in full of TÜV Rheinland do Brasil followed by its identification number (OCP-0004), i.e. TÜV RHEINLAND OCP-0004 or UCIEE OCP ) In case of wires, cables and cords, of section 2,5mm² or smaller than, that for their dimensions, make impossible the clear printing of the conformity marking of the items a) and b), will be allowed the use of the name in full of INMETRO and the name in full of TÜV Rheinland followed by its identification number, i.e., INMETRO TÜV RHEINLAND OCP-0004 or INMETRO UCIEE OCP ) On the product of section 1mm² or smaller, the Conformity Marking is optional, being, although, obligatory on the packings / labels.

16 Page: 16/16 ANNEX E USE OF THE LICENSE, CERTIFICATION PER LOT E.1 For the use of the license for the certification per lot, see the INMETRO rules related as below: NBR NM rule nº 87 from 20/05/2003 NBR rule nº 85 from 26/05/2003 NBR 7288 rule nº 86 from 26/05/2003 ABNT NBR rule nº 281 from 19/07/2007 ABNT NBR rule nº 282 from 19/07/2007 ABNT NBR rule nº 281 from 19/07/2007

COMPLEMENT. Switches for Electrical Fixed Installations for household and similar purposes

COMPLEMENT. Switches for Electrical Fixed Installations for household and similar purposes COMPLEMENT Doc: 702-CRC-003-E Revision: 07 Page: 1/8 Elaborated by: Nelson Coelho/ Douglas Ferreira Checked by: Vanessa Hernandes Approved by: Nelson Coelho Approval date: 21/07/2016 1 OBJECTIVE This document

More information

ELECTRONIC BALLASTS FOR FLUORESCENTS LAMPS NBR e NBR 14418

ELECTRONIC BALLASTS FOR FLUORESCENTS LAMPS NBR e NBR 14418 COMPLEMENT Doc: 704-CRC-002-ILM ELECTRONIC BALLASTS FOR FLUORESCENTS LAMPS NBR 14417 e NBR 14418 Review: 05 page: 1/5 Prepared by: João Damião Checked by: Vanessa Hernandes Approved by: Arnaldo Barbulio

More information

COMPLEMENT CIRCUIT BREAKERS. Prepared by: Laercio Lopes dos Santos Checked by: Vanessa Hernandes

COMPLEMENT CIRCUIT BREAKERS. Prepared by: Laercio Lopes dos Santos Checked by: Vanessa Hernandes COMPLEMENT Doc: 702-CRC-002 Page: 1/20 Prepared by: Laercio Lopes dos Santos Checked by: Vanessa Hernandes Approved by: Nelson Coelho Approval Date: 21/06/2016 1 OBJECTIVE This document presents the additional

More information

COMPLEMENT SAFETY CERTIFICATION HOUSE APPLIANCES AND SIMILAR

COMPLEMENT SAFETY CERTIFICATION HOUSE APPLIANCES AND SIMILAR Pages: 1/15 Created by: Fabio Sora de Araujo Verified by: Karen Carolina Martins Approved by: João Damião Date of Approval: 24/07/2015 1. OBJECTIVE Establish criteria for the Program for Conformity Assessment

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60502-2 Second edition 2005-03 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 2: Cables

More information

U.V resistance UL Sunlight Resistance. Flame retardant IEC

U.V resistance UL Sunlight Resistance. Flame retardant IEC Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

2.2 Copies of any records and other connected papers that may be required by the Bureau shall be made available at any time on request.

2.2 Copies of any records and other connected papers that may be required by the Bureau shall be made available at any time on request. DOC:STI/694/8 July 2004 SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PVC INSULATED CABLES (FOR VOLTAGES UPTO AND INCLUDING 1100 VOLTS) ACCORDING TO IS:694:1990 (Including amendment No.1 &2) 1.

More information

COMPLEMENT. RoHS PRODUCTS. Prepared by: Karin Medeiros Verified by: Natália Silva. Approved by: Mariano Mercado Approval Date: 15/01/2016

COMPLEMENT. RoHS PRODUCTS. Prepared by: Karin Medeiros Verified by: Natália Silva. Approved by: Mariano Mercado Approval Date: 15/01/2016 Page: 1/5 Prepared by: Karin Medeiros Verified by: Natália Silva Approved by: Mariano Mercado Approval Date: 15/01/2016 1. OBJECTIVE This document presents the complementary criteria of Product Certification

More information

Accreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan.

Accreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan. Issue : 10/08/15 Accreditation No: Awarded to al Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan. The scope of accreditation is in accordance with the standard specifications

More information

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 REVISION NO. 0 NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0 PAGE NO. 1 OF 24 DATE OF ISSUE (MONTH/YEAR) TOTAL NO. OF PAGES (Including cover

More information

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 4

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 4 TITLE SPECIFICATION FOR PVC ADHESIVE REFERENCE REV DATE: JUNE 2011 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD... 3 INTRODUCTION... 4 1 SCOPE... 4 2 NORMATIVE REFERENCES... 4 3 DEFINITIONS AND ABBREVIATIONS...

More information

This document is a preview generated by EVS

This document is a preview generated by EVS IEC 60502-2 Edition 3.0 2014-02 REDLINE VERSION colour inside Power cables with extruded insulation and their accessories for rated voltages from 1 kv (Um = 1,2 kv) up to 30 kv (Um = 36 kv) Part 2: Cables

More information

11-SDMS-01 REV. 03 ( )

11-SDMS-01 REV. 03 ( ) 11-SDMS-01 REV. 03 (19-07-2018) SPECIFICATION FOR LOW-VOLTAGE POWER AND CONTROL CABLES Saudi Electricity Company 1. SCOPE... 3 2. CROSS REFERENCES TO OTHER SEC STANDARDS... 3 3. APPLICABLE CODES AND STANDARDS...

More information

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) EDC3 (5239) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV) TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 Table of Contents

More information

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category. Superastic Flex Extra sliding for extra easy installation. Superastic Flex cables are ideal for those who want to save installation

More information

AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS :2009

AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS :2009 MS 2112-1:2009, AMD. 1:2015 AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS 2112-1:2009 ELECTRIC CABLE AND WIRE - POLYVINYL CHLORIDE (PVC) INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750

More information

ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables

ANSI/NEMA WC ICEA S Standard for Control, Thermocouple Extension, and Instrumentation Cables Approved as an American National Standard ANSI Approval Date: October 31, 2014 ANSI/NEMA WC 57-2014 ICEA S-73-532-2014 Standard for Control, Thermocouple Extension, and Instrumentation Cables Prepared

More information

MATERIAL STANDARD FOR CABLES AND WIRES

MATERIAL STANDARD FOR CABLES AND WIRES MATERIAL STANDARD FOR CABLES AND WIRES CONTENTS : PAGE No. 1. SCOPE... 2 2. SERVICE CONDITIONS... 2 3. REFERENCES AND STANDARDS... 2 4. UNITS... 3 5. CABLE DESIGN AND CONSTRUCTION... 3 5.1 Applicable Cable

More information

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT

P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEB SPECIFICATION 005-1: 2012 P.V.C. INSULATED ALUMINIUM SERVICE MAIN WIRE-FINISHED PRODUCT CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS PAGE 1. Scope 03

More information

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE. ANSI/ICEA S-108-720-2012 STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV Approved by AMERICAN NATIONAL STANDARDS INSTITUTE November 27, 2012 Publication # ANSI/ICEA S-108-720-2012

More information

NPS/002/023 Technical Specification for 132kV Power Cables.

NPS/002/023 Technical Specification for 132kV Power Cables. Version:- 2.2 of Issue:- June 09 Page 1 of 11 NPS/002/023 Technical Specification for 132kV Power Cables. 1. Purpose The purpose of this document is to detail the technical requirements of Northern Powergrid

More information

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Issued date: June, 2017 THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-77 for Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484. Translated English of Chinese Standard: TB/T1484.2-2010 www.chinesestandard.net Sales@ChineseStandard.net RAILWAY INDUSTRY STANDARD TB OF THE PEOPLE S REPUBLIC OF CHINA ICS 29.280 S 35 Partially replacing

More information

Test Report No.: Page 2 of 34

Test Report No.: Page 2 of 34 Test Report No.: 50093985 001 age 2 of 34 Test Report AS/NZS 5000.2:2006 Electric cables olymeric insulated for working voltages up to and including 450/750V Test item particulars: 1C 4mm 2 to 16 mm 2

More information

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Edition Nº: 9 THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-76 for Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable for Rated Voltage U0/U = 0.6/1.0

More information

6A V CVQ cable (C rank)

6A V CVQ cable (C rank) 6A-31 600V CVQ cable (C rank) Enactment in July 1977 Approved on June 27, 2008 (revised 02) Enforcement on July 28, 2008 Distribution Department Tokyo Electric Power Company, Incorporated. 1. Scope of

More information

P.V.C. INSULATED UNARMOURED COPPER CABLES

P.V.C. INSULATED UNARMOURED COPPER CABLES 083 : 2007 CEB SPECIFICATION P.V.C. INSULATED UNARMOURED COPPER CABLES CEYLON ELECTRICITY BOARD SRI LANKA Specification for P.V.C. INSULATED UNARMOURED COPPER CABLES CEB Specification 083 : 2007 CEYLON

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables Version: 4.0 Date of Issue: October 2015 Page: 1 of 21 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements

More information

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained. SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF CROSSLINKED POLYETHYLENE INSULATED THERMOPLASTIC SHEATHED CABLES FOR WORKING VOLTAGES UPTO AND INCLUDING 1100 VOLTS ACCORDING TO IS 7098(Part 1):1988

More information

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE Engineering Specification Electrical Networks L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 400mm 2 ALUMINIUM OR COPPER CONDUCTOR 3.8/6.6kV XLPE INSULATED WITHOUT METALLIC SCREEN PVC Version:

More information

DOC: STI/8783(Part 4/Sec1)/1 August 1998

DOC: STI/8783(Part 4/Sec1)/1 August 1998 SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF Winding Wires for Submersible Motors Part 4 Specification for Individual Wires Sec 1 HR PVC Insulated Wires ACORDING TO IS: 8783(Part 4/Sec 1): 1995

More information

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable. Spec. No. GO 5821-4361Rev.2 Issued date : July 13, 2005 Revised 1 date : April 29, 2015 Revised 2 date : February 19, 2016 Specification FOR 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated

More information

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor TABLE OF CONTENTS SECTION SUBJECT PAGE I. SCOPE...1 II. APPLICABLE DOCUMENTS...1 III. CONDUCTOR...2 IV. SEPARATOR...2 V. INSULATION...2 A. Physical Properties...2 B. Electrical Properties...3 C. Qualification

More information

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE 137-1: 2015 CEB SPECIFICATION XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE CEYLON ELECTRICITY BOARD SRILANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope

More information

ISO 6722 INTERNATIONAL STANDARD. Road vehicles 60 V and 600 V single-core cables Dimensions, test methods and requirements

ISO 6722 INTERNATIONAL STANDARD. Road vehicles 60 V and 600 V single-core cables Dimensions, test methods and requirements INTERNATIONAL STANDARD ISO 6722 Second edition 2006-08-01 Road vehicles 60 V and 600 V single-core cables Dimensions, test methods and requirements Véhicules routiers Câbles monoconducteurs de 60 V et

More information

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables Version: 4.1 Date of Issue: February 2016 Page: 1 of 25 NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables 1. Purpose The purpose of this document is to detail the requirements

More information

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables) POLARIS CABLES & WIRES PVT. LTD. (An IS & ISO 9001 :2000 Certified Company) Plant : Plot 35, Genesis Indl Complex, Kolgaon, PALGHAR, Dist :Thane, Maharashtra. MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP

More information

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN Engineering Specification Electrical Networks MESP 030000-04 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 70mm 2 FLEXIBLE TINNED COPPER CONDUCTOR 3.3kV EPR INSULATED WITHOUT METALLIC SCREEN Version: 1 Issued:

More information

Technical Specification for Plastic-Insulated Low Voltage Cables

Technical Specification for Plastic-Insulated Low Voltage Cables Page 1/9 Technical Specification for Plastic-Insulated Low Voltage Cables This technical specification is valid for the business unit E.ON Sweden of the market unit E.ON Nordic With this specification,

More information

Test Report No.: Page 2 of 35

Test Report No.: Page 2 of 35 Test Report No.: 50093959 001 age 2 of 35 Test Report AS/NZS 5000.1:2005 including amendment 1 Electric cables olymeric insulated for working voltages up to 0.6/1kV Test item particulars: 1C 4mm 2 to 16

More information

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Single Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Edition Nº: 7 NPS - 96 Issued date: June, 2017 LV, single core, Aluminum, XLPE Power Cable THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS - 96 for Single Core, Aluminum Conductor Extruded Cross

More information

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES 11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE

More information

NEMA Standards Publication No. WC ICEA Publication No. S

NEMA Standards Publication No. WC ICEA Publication No. S NEMA Standards Publication No. WC 71-1999 ICEA Publication No. S-96-659-1999 Standard for Nonshielded Cables Rated 2001-5000 Volts for use in the Distribution of Electric Energy Published by National Electrical

More information

COMPILED BY FUNCTIONAL RESP APPROVED BY AUTHORIZED BY TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE TYPES... 3

COMPILED BY FUNCTIONAL RESP APPROVED BY AUTHORIZED BY TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE TYPES... 3 TITLE SPECIFICATION FOR INSULATING PUTTY DATE: JANUARY 2006 PAGE: 1 OF 11 COMPILED BY FUNCTIONAL RESP APPROVED BY AUTHORIZED BY TABLE OF CONTENTS Page FOREWORD... 3 INTRODUCTION... 3 1 SCOPE... 3 2 TYPES...

More information

Four Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

Four Core, Aluminum Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable Edition Nº: 7 Issued date: February, 2017 NPS 91 Specifications for THE ISRAEL ELECTRIC CORPORATION LTD. Specification No. NPS-91 for Four Core, Aluminum Conductor Extruded Cross - Linked Polyethylene

More information

6A-51 DV wire (C rank)

6A-51 DV wire (C rank) 6A-51 DV wire (C rank) Established in March, 1955 March 3, 2014 (revised 12) Enforcement on April 3, 2014 Distribution Department Tokyo Electric Power Company, Incorporated Japanese document. In cases

More information

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 ) 138-1: 2015 CEB SPECIFICATION AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 ) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 8051 Fax: +94 11 232 5387 CONTENTS Page 1.0 Scope 3 2.0 System

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-31441-5 SOUTH AFRICAN NATIONAL STANDARD Electric cables with extruded solid dielectric insulation for fixed installations (300/500 V to 1 900/3 300 V) Part 3: PVC Distribution cables WARNING

More information

SURFACE VEHICLE STANDARD

SURFACE VEHICLE STANDARD 400 Commonwealth Drive, Warrendale, PA 15096-0001 SURFACE VEHICLE STANDARD J1654 Issued 1994-06 Revised 2000-05 REV. MAY2000 Submitted for recognition as an American National Standard Superseding J1654

More information

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

NPS/002/020 Technical Specification for 11 & 20kV Power Cables Version:- 3.1 of Issue:- Nov - 09 Page 1 of 11 NPS/002/020 Technical Specification for 11 & 20kV Power Cables 1. Purpose The purpose of this document is to detail Northern Powergrid (the Company) requirements

More information

6A-089: 600-V CV Cables (Rank C)

6A-089: 600-V CV Cables (Rank C) 6A-089: 600-V CV Cables (Rank C) Established: December 4, 2014 Enforced: January 4, 2015 Power Distribution Department TEPCO Power Grid, Incorpora bject to change without notice. TEPCO Power Grid, Incorpora

More information

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Approved as an American National Standard ANSI Approval Date: February 23, 2009 ANSI/NEMA WC 70-2009 ICEA S-95-658-2009 Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy Published

More information

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE SEAL & SIGNATURE OF THE TENDERER PAGE 1 OF 14 TECHNICAL SPECIFICATION FOR LT XLPE POWER CABLES (SPECIFICATION NO.MM/I/LTXLPE/2006) 1. SCOPE: The specification

More information

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/LTPVC & CONTROL/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION

More information

COMPILED BY FUNCTIONAL RESP. APPROVED BY AUTHORIZED BY TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES...

COMPILED BY FUNCTIONAL RESP. APPROVED BY AUTHORIZED BY TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES... TITLE SPECIFICATION FOR PVC ADHESIVE DATE: JUNE 2017 PAGE: 1 OF 19 COMPILED BY FUNCTIONAL RESP. APPROVED BY AUTHORIZED BY. TLADI CONSULTING.. Z NGQWALA TECHNICIAN UNDERGROUND. M MAGEMBA GENERAL MANAGER:(A)

More information

Tele-Fonika Cable Americas

Tele-Fonika Cable Americas PUMP Cables Tele-Fonika Kable 2 TELE-FONIKA Kable S A, a privately held wire and cable manufacturer headquartered in Krakow, Poland, is one of the largest wire and cable companies in the world. TF operates

More information

Green Product Mark Certification Scheme

Green Product Mark Certification Scheme Green Product Mark Certification Scheme www.tuv.com FOREWORD Product environmental labels are claims regarding the environmental impact of a product. They provide information about the product s overall

More information

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable OFFSHORE CABLES NEK 606 : 2016 with FIREBAR the TOTAL SAFETY fire and water resistant cable System certifications CCI Quality CCI Evironmental CCI Evironmental CCI Health & Safety CABLE SERVICE Quality

More information

2. RATED VOLTAGE: The rated voltage of the AB cables shall be 1100 volts

2. RATED VOLTAGE: The rated voltage of the AB cables shall be 1100 volts TECHNICAL SPECIFICATION OF LT AERIAL BUNCHED CABLES FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) (Size 1C x35mm²+1c x16 + 25mm² and 2C x50mm² +1Cx25 + 35mm²) 1. SCOPE: This specification

More information

*** Supercedes: BECO E and COM , , & ***

*** Supercedes: BECO E and COM , , & *** 7/27/09 Page 1 of 9 R5 *** Supercedes: BECO E2.9-27.4 and COM 1-0696, 2-0196, & 5-0385 *** 1.0 Scope #2 AWG to 1000 KCMIL CONCENTRIC NEUTRAL JACKETED CABLES RATED 5-35 kv These Specifications cover single

More information

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath 0.6/1 kv LOW VOLTAGE CONTROL CABLES PVC OR XLPE INSULATED, PVC SHEATHED AS PER IEC 60502-1 Conductors Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular

More information

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

The Contractor shall furnish and install all shielded power cable suitable for use on this project. Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS

More information

STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV

STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV ANSI/ICEA S-94-649-2013 STANDARD FOR CONCENTRIC NEUTRAL CABLES RATED 5 THROUGH 46 KV Approved by AMERICAN NATIONAL STANDARDS INSTITUTE March 19,2013 Publication # ANSI/ICEA S-94-649-2013 2013 by INSULATED

More information

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY)

SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) SPECIFICATION OF LT AERIAL BUNCHED (AB) CABLES (Size: 3C x 35mm² +1C x16 + 25mm²) FOR LT LINES (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) 1. SCOPE: This specification covers XLPE insulated

More information

26/35kV Copper XLPE Insulation Electric Cable

26/35kV Copper XLPE Insulation Electric Cable 26/35kV Copper XLPE Insulation Electric Cable Specifications 1.1~35kv XLPE insulated power cable 2.Standard: IEC,VDE,BS,UL,AS/NZS Black PVC sheath XLPE insulated armored copper power cable YJV22 YJV32

More information

TECHNICAL SPECIFICATION OF UNARMOURED FLAT 1100 VOLTS L.T. PVC INSULATED TWIN CORE 4.0mm² CABLE WITH ROUND ALUMINIUM CONDUCTOR BLACK SHEATHED.

TECHNICAL SPECIFICATION OF UNARMOURED FLAT 1100 VOLTS L.T. PVC INSULATED TWIN CORE 4.0mm² CABLE WITH ROUND ALUMINIUM CONDUCTOR BLACK SHEATHED. TECHNICAL SPECIFICATION OF UNARMOURED FLAT 1100 VOLTS L.T. PVC INSULATED TWIN CORE 4.0mm² CABLE WITH ROUND ALUMINIUM CONDUCTOR BLACK SHEATHED. I. SCOPE: This specification covers Manufacture, testing at

More information

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways. SECTION 16120 WIRE, CABLE AND BUSWAYS PART 1 - GENERAL 1.01 DESCRIPTION: A. This section specifies providing wire, cable and busways. B. Definitions: 1. Cable: Cable having low smoke generating characteristics.

More information

Abu Dhabi Certification Scheme for Polyethylene Plastic Pipe Systems Used for Utilities

Abu Dhabi Certification Scheme for Polyethylene Plastic Pipe Systems Used for Utilities Abu Dhabi Certification Scheme for Polyethylene Plastic Pipe Systems Used for Utilities Assessment and Surveillance Plan Page 1 of 14 TABLE OF CONTENTS ABOUT THE ABU DHABI QUALITY AND CONFORMITY COUNCIL

More information

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 22 kv, SINGLE CORE, 95mm 2 COPPER

MESP TECHNICAL SPECIFICATION FOR ELECTRIC CABLE 22 kv, SINGLE CORE, 95mm 2 COPPER Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR ELECTRIC CABLE Version: 1 Issued: March 2014 Owner: Electrical Networks Asset Manager Approved By: George Marulli Electrical Networks

More information

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for STANDARD SPECIFICATION FOR SIGNAL CABLE 1.01 SCOPE A. This Specification provides for single and multi-conductor insulated and jacketed cable for installation in direct contact with the earth, in ducts,

More information

JB/T Translated English of Chinese Standard: GB/T

JB/T Translated English of Chinese Standard: GB/T Translated English of Chinese Standard: GB/T8734.3-2012 www.chinesestandard.net Sales@ChineseStandard.net MACHINERY INDUSTRY STANDARD OF JB THE PEOPLE S REPUBLIC OF CHINA ICS 29.060.20 K 13 Record No.

More information

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.

More information

Q-MARK REGISTRATION SCHEDULE FOR STRUCTURAL PLYWOOD

Q-MARK REGISTRATION SCHEDULE FOR STRUCTURAL PLYWOOD Q-MARK REGISTRATION SCHEDULE FOR STRUCTURAL PLYWOOD Company : Huaian Arser Wood Co. Ltd Address : No 10 Yanhuang Road West Industrial Zone Lianshui Jiangsu China Establishment ID : 056/2698 Contents Page

More information

project 36 MW 1.0 INTRODUCTION AND PROJECT INFORMATION

project 36 MW 1.0 INTRODUCTION AND PROJECT INFORMATION 1.0 INTRODUCTION AND PROJECT INFORMATION Welspun Energy Ltd. is executing 18MW + 18MW + 14MW Solar PV Power Project for Mahagenco in Maharashtra (Site Location: Shirsuphal, Baramati Taluka, District Pune,

More information

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] [6.35/11kV Copper XLPE Three-Core HDPE Sheathed] APPLICATION Mostly used as feeder electric cable for power distribution network such as power supply station, substation, switching system etc. They are

More information

5.2 The phase conductors shall be provided with one, two & three ridges for easy identification.

5.2 The phase conductors shall be provided with one, two & three ridges for easy identification. LT Aerial Bunched Cables for LT Lines (APPLICABLE FOR LT AB CABLE WITH XLPE INSULATION ONLY) 1. SCOPE: This specification covers XLPE insulated Aluminum cable twisted over a central bare Aluminum Alloy

More information

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE TI 20 PVC TI 20 INSULATED TELEPHONE WIRE Standard: Nominal voltage: Temperature range - fixed laying: Cable Structure: Application: Packing: 2x0,5 0,4 2,6 3,6 7,2 2x0,6 0,4 2,8 5,2 9,1 2x0,8 0,4 3,2 9,2

More information

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE) Profile No.: 4 NIC Code: 27320 ELECTRICAL CABLES (SINGLE AND MULTICORE) 1. INTRODUCTION: Electrical Cables and wires are used for power distribution in electrical systems in housing sector as well as in

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 05 19.10 10 (May 2016) ----------------------------------- Preparing Activity: USACE Superseding UFGS-26 05 19.00 10 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

SPECIFICATION FOR FRLS POWER CABLES

SPECIFICATION FOR FRLS POWER CABLES SPECIFICATION FOR FRLS POWER CABLES 1.0 SCOPE This specification cover the technical requirements of design, manufacture, testing and delivery to site of Power Cables of 1100V grade with FRLS PVC Sheathed,

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.018 Version 1 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS SPECIFICATIONS FOR BARE COPPER CONDUCTORS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018 STANDARDS UPDATE NOTICE (SUN) ISSUED: February 23, 2018 STANDARD INFORMATION Standard Number: UL 83 / CSA C22.2 No 75 / NMX-J-010-ANCE Standard Name: Thermoplastic-Insulated Wires and Cables Standard Edition

More information

Cables de Comunicaciones Zaragoza. CW1601 Approval application.

Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. GENERAL INFORMATION 1.1 LIST OF CONTENTS Cables de Comunicaciones Zaragoza. CW1601 Approval application. 1. General Information 1.1 List of Contents 1.2 Contractors Name 1.3 Test report 1.4 Product

More information

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified - Screened power and control cable for versatile use in power chains with UL/cUL AWM certification.

More information

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 ANNEXURE TO TENDER NO. PUR42396GM DATED 06 th FEBRUARY 2014 SUPPLY OF 1.1KV GRADE LT POWER CABLES FOR THE PERIOD APRIL 2014 MARCH 2016 TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1 1.1 SCOPE

More information

GEMSCAB INDUSTRIES LIMITED STANDARD PLAN FOR HT XLPE CABLES AS PER IS:7098(PART-II)

GEMSCAB INDUSTRIES LIMITED STANDARD PLAN FOR HT XLPE CABLES AS PER IS:7098(PART-II) -1 RAW MATERIAL INSPECTION 1.1 ALUMINIUM ROD/COPPER ROD (i) Diameter 100% IS:5484 & IS:613 IS:5484 & IS:613 GIL-GIR-006 IQC (ii) Conductivity or resistivity 100% IS:5484 & IS:613 IS:5484 & IS:613 GIL-GIR-006

More information

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

NORMAS DE REFERENCIA AEIC CS 1: ASTM B AEIC CS 1: Especificación para Solid-Type Impregnated-Paper-Insulated Metallic Sheathed AEIC CS2: Especificación para Impregnated-Paper and Laminated Paper- Polypropylene Insulated, High- Pressure Pipe-Type

More information

Flexible Cables for Cranes and other industrial applications

Flexible Cables for Cranes and other industrial applications Flexible Cables for Cranes and other industrial applications Fujikura Ltd. Version 3 Update Aug.13, 2014 1 Cable selection depending on the application Application 2/3PNCT-B G-/3PNCT-B 2/3PNCT-H 2/3PNCT-H-U

More information

Guidance on Registration System for Components and Materials used in Electrical Appliances (CMJ) and Guide for Application for Registration

Guidance on Registration System for Components and Materials used in Electrical Appliances (CMJ) and Guide for Application for Registration Guidance on Registration System for Components and Materials used in Electrical Appliances (CMJ) and Guide for Application for Registration (Equipment Wire Version) October 2011 JAPAN QUALITY ASSURANCE

More information

Separator, suitable tape between the braid and outer sheath

Separator, suitable tape between the braid and outer sheath Picture is for information only. Applicable standards: NEK TS 606 Code S1/S5, IEC 60092-376- Design guidelines IEC 60228 conductor IEC 60092-351 Insulating material, IEC 60092-359 Sheathing materials IEC

More information

COMESA HARMONISED COMESA/DHS STANDARD 227-1: 2005

COMESA HARMONISED COMESA/DHS STANDARD 227-1: 2005 COMESA HAMONISED COMESA/DHS STANDAD 227-1: 2005 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (Um = 1,2 kv) up to 30 kv (Um = 36 kv) - Part 1: Cables for rated

More information

Document 2007 Rev 0 December 2005 Page 1 of 8

Document 2007 Rev 0 December 2005 Page 1 of 8 Document 2007 Rev 0 December 2005 Page 1 of 8 1. Scope... 2 2. Definitions... 2 a. LabTest...2 b. Factory Location/ Manufacturer's Premises...2 c. Manufacturer...2 d. Subcontractor...2 e. f. Out-Worker...2

More information

6A-38 Jumper Wire (IJP) (Rank A)

6A-38 Jumper Wire (IJP) (Rank A) DISCLAIMER: This translation may be used for reference purpose only. This English version is not an official translation of the original Japanese document. In cases where any differences occur between

More information

TECHNICAL CONFORMITY ASSESSMENT

TECHNICAL CONFORMITY ASSESSMENT GLOBAL STANDARD Page 1 of 18 This document is intellectual property of Enel Spa; reproduction or distribution of its contents in any way or by any means whatsoever is subject to the prior approval of the

More information

SIRIM QAS International Sdn. Bhd.

SIRIM QAS International Sdn. Bhd. SIRIM QAS International Sdn. Bhd. PRODUCT CERTIFICATION SCHEMES INTRODUCTION APPLICABILITY A manufacturer or company may apply to SIRIM QAS International for a certification of product against requirements

More information

RP Revision 10. Date

RP Revision 10. Date AENOR Mark Specific Rules for polyethylene compounds (PE) intended for the manufacturing of pipes and fittings for water supply and sewerage under pressure Note: This document is a translation of the Spanish

More information