1 Straight Base Metal Thermocouple Elements The straight base metal thermocouple elements illustrated on this catalog page are replacement elements for use in Pyromation's complete industrial thermocouple assemblies as found elsewhere in this catalog section. These replacement elements are also compatible for use in other manufacturers' thermocouple assemblies. These thermocouples are available as bare wire or ceramic insulated elements, with options as listed below, and with special construction designs. BARE ELEMENT INSULATED JUNCTION INSULATED ELEMENT TWIST WELD DUPLEX INSULATED TIG WELD /2 NOMINAL ORDER S K8 C M - -,34 Single Straight Element Type (Type + Wire Gauge) J8 J J4 J20 Iron - Constantan K8 K K4 K20 Chromel - Alumel N8 N4 Nicrosil - Nisil DUPLEX STRAIGHT ELEMENTS Use thermocouple type code letter twice. Example: JJ4 or KK. Dual elements with ceramic insulators are supplied as two single elements. 2 Element Insulation WIRE GAUGE O Bare Element None Used C Oval Ceramic INSULATOR DIMENSIONS SINGLE DUPLEX 8 Ga x 0.28 Ga x Ga x Ga OD OD R Round Ceramic Ga OD OD 4 Ga OD OD 20 Ga OD 0.88 OD The above insulated elements are supplied with refractory insulators: 277 C [2330 F] maximum temperature. Element Options M Special limits wire - types J and K (consult factory for other types) 4 Element Options 0 Standard weld as noted below Twist and tig weld (not available with 8 gauge duplex) 2 Tig weld without twist L Insulated hot junction 34 Single terminal block on element 342 Duplex terminal block on element Unless specified by option numbers above, all 8,, and 4 gauge elements will be provided with Opt. 2 (tig weld without twist). 20 gauge elements will be provided with Opt. (twist and tig weld). All elements, regardless of gauge, over 96" will be supplied with Option (twist and tig weld). 3 Element Length Specify other lengths in inch increments. Actual cut length will be (/2)" longer than specified length to allow for terminal connections. 2-6 IND-
2 Angle Base Metal Thermocouple Elements The angle base metal thermocouple elements illustrated on this catalog page are replacement elements for use in Py ro ma tion's complete angle thermocouple assemblies as found elsewhere in this catalog section. These replacement elements are also compatible for use in other manufacturers' angle thermocouple assemblies. These thermocouples are available with the options listed below and with special construction designs. These replacement elements are shipped in a straight configuration and are to be bent at the time of installation. 4 TYPICAL COLD LEG /2 NOMINAL INSULATED JUNCTION H O T L E G TWIST WELD TIG WELD ORDER S K8 A , L, 34 Single Angle Element Type (Type + Wire Gauge) J8 J J4 Iron - Constantan K8 K K4 Chromel - Alumel N8 N4 Nicrosil - Nisil DUPLEX ANGLE ELEMENTS Requires the use of 2 single elements. 2 Element Insulation INSULATOR WIRE GAUGE INSULATOR DIMENSIONS SINGLE Two hole oval ce ram ic in su la tors 8 Ga x 0.28 A on hot and cold legs. Ball and Ga x sock et in su la tors at bend 4 Ga x 0.28 The above insulated elements are supplied with refractory insulators: 277 ºC [2330 ºF] maximum temperature. Element Options M Special limits wire - types J and K (consult factory for other types) 3 Hot Leg Length Specify Other Lengths 5 Element Options 0 Standard weld as noted below Twist and tig weld 2 Tig weld without twist L Insulated hot junction 34 Single terminal block on element 342 Duplex terminal block on element Unless specified by option numbers above, all 8,, and 4 gauge elements will be provided with Opt. 2 (tig weld without twist). All elements, regardless of gauge, over 96" will be supplied with Option (twist and tig weld). 4 Cold Leg Length Specify other lengths in inch increments. Actual cut length will be (/2) longer than specified length to allow for terminal connections. IND-2 3-5
3 Noble Metal Platinum Thermocouple Elements The noble metal platinum thermocouple elements illustrated on this catalog page are replacement elements for use in Pyromation's complete high temperature industrial thermocouple assemblies as found elsewhere in this catalog sec tion. These re place ment elements are also compatible for use in other manufacturers' high temperature ther mo cou ple as sem blies. All in su lat ed elements are supplied with high temperature alumina insulators and are available with the options as listed below. Element types R, S, and B are supplied with a fusion weld. Custom designed constructions are available. INSULATED ELEMENT without COLLAR (supplied with recessed junction as standard) INSULATED ELEMENT with COLLAR 2 NOMINAL Note: Elements supplied without collars are intended to be used with ceramic tubes that are not supplied with hex fittings. 2 NOMINAL Note: Elements supplied with collars are intended to be used with ceramic tubes with hex fittings. ORDER S R R Single Straight Element Type (Type + Wire Gauge) R R26 Platinum - Platinum 3% Rhodium S S26 Platinum - Platinum 0% Rhodium Platinum - 30% Rhodium - Platinum B 6% Rhodium DUPLEX STRAIGHT ELEMENTS Use thermocouple type code letter twice. EXAMPLES: RR or SS26 2 Element Insulation INSULATOR WIRE GAUGE O Uninsulated Bare Element None R Round, 99.7% Alumina Insulator (4-hole, single and duplex) 87 º C [3400 º F] maximum temp. 26 INSULATOR DIMENSIONS SINGLE and DUPLEX 0.88 OD w OD Collar 0.88 OD w OD Collar Element Options M Reference grade (consult factory for other types) 4 Element Options 3 Supplied without ceramic collar L Recessed insulated hot junction 3 Element Length Specify other lengths in inch increments. 4-7 IND-3
4 Standard Service Metal Alloy Protection Tubes The thermocouple protection tubes illustrated on this catalog page are replacement tubes for Pyromation s complete thermocouple assemblies as found elsewhere in this catalog section. They are compatible replacements for other manufacturers protection tubes. The materials of construction are those most commonly used in general purpose in dus tri al process heating applications. These protection tubes are available with the options as listed below, with other pipe schedule sizes, and they can be supplied with custom designed constructions. TUBE with OPTIONAL WELDED BUSHING TUBE with FLANGE OPTION H TUBE with TEMPERATURE CHECK FITTING ORDER S D6 Protection Tube NPT Connections NPT SIZE PIPE SCHED. [] CARBON STEEL 538 ºC [000 º F] Max / / / SS 927 ºC [700 º F] Max / / / SS 093 ºC [2000 º F] Max / /4 40 INCONEL ºC [200 º F] Max / /4 40 INCONEL ºC [2300 º F] Max / / [] Schedule 80 and 60 are available in some alloys as special order items. Consult factory for price and delivery. 2 Tube Length Specify other lengths in inch increments. 3 Protection Tube Options A Open end tube (closed end stan dard) H Adjustable steel mounting flange NT Supplied without threads 6Y Steel temperature check fitting Optional Welded Bushings STEEL 36 SS BUSHING SIZE 6C(U) 8C(U) 6D(U) 8D(U) /2 NPT Bushing (25 tubes only) 3/4 NPT Bushing (25 and 50 tubes only) NPT Bushing 6E(U) 8E(U) (25, 50, and 75 tubes only) 6F(U) 8F(U) (/4) NPT Bushing 6G(U) 8G(U) (/2) NPT Bushing Substitute insertion length, in inches, mea sured from hot tip to bottom of bushing for (U) above. Insert NW in place of insertion length (U) for bushing sup plied loose on tube. Metal Alloy Tube Dimensions PIPE SIZE OD SCH. 40 ID SCH. 80 ID SCH. 60 ID / / / IND-4 5-5
5 Special Service Protection Tubes The protection tubes listed below are designed for use in high temperature corrosive service applications. The Series 4 protection tubes are used in waste incineration, cement and lime kilns, utility and recovery boilers, fluidized bed combustion systems, and other harsh process environments when high levels of sulphur, chlorides, ash, and salt deposits are commonly found. The Series 2 protection tubes are also excellent choices for use in waste incineration, immersion into molten copper, brass, basic steels and slag, and for use in open hearth furnaces, soaking pits, and blast furnace applications. TUBE 2 (see note below) Note: Series 2 tubes dimensions are fixed at approximately less than specified length. TUBE with TEMPERATURE CHECK FITTING x 3/4 Steel Hex Fitting Standard. No optional welded bushings are necessary. TUBE 4 with FLANGE OPTION H TUBE 4 with OPTIONAL BUSHING ORDER S E6 Protection Tube NPT Connections NPT SIZE PIPE SCHED. HR ºC [2200 º F] Max / / / / LT- 37 ºC [2500 º F] Max n/a OD ID 2 Tube Length Specify other lengths in inch increments. 3 Protection Tube Options A Open end tube (closed end stan dard) H Adjustable steel mounting flange NT Supplied without threads 6Y Steel temperature check fitting Optional Welded Bushings For Series 4 STEEL 36 SS BUSHING SIZE 6D(U) 8D(U) 3/4 NPT Bushing (50 tubes only) 6E(U) 8E(U) NPT Bushing (50 and 75 tubes only) 6F(U) 8F(U) (/4) NPT Bushing 6G(U) 8G(U) (/2) NPT Bushing Substitute insertion length, in inches, mea sured from hot tip to bottom of bushing for (U) above. Insert NW in place of insertion length (U) for bushing sup plied loose on tube. 6-6 IND-5
6 Special Service Protection Tubes The Series, 3, and 4 protection tubes are used to protect thermocouple elements in molten aluminum and zinc applications such as diecasting, melting, smelting, and high temperature holding furnace environments. Series 8 Silicon Carbide protection tube can also be used in the above applications, however the Series 8 is a refractory silicate bonded tube and generally will not provide a service life equal to silicon nitride bonded silicon carbide protection tubes. The Series 8 is satistactory for use in other molten metals, molten glass, and other high temperature applications. Series 3, 4, and 8 protection tubes should be preheated and slowly immersed into any molten materials. TUBE TUBE 3 TUBE 8JC NOMINAL /2 NOMINAL TUBE 4 /2 NOMINAL ORDER S Protection Tube NPT Connections NPT SIZE TUBE OD ID CAST IRON 87 ºC [600 ºF] Max Internally thread ed 3/ VESUVIUS 927 ºC [700 ºF] Max / SILICON CAR BIDE 649 ºC [3000 ºF ] Max. 8J Plain tube w/o collar None JC 3" OD collar None CERITE 85 ºC [300 ºF] (36 maximum length) 4-50 [] Cerite II / [] For Cerite protection tubes supplied with 36SS pipe instead of a carbon steel pipe, change model number prefi x code 4 to 48. EXAMPLE: MAX. 2 Tube Length Recommended Applications CAST IRON Aluminum VESUVIUS Aluminum SILICON CARBIDE (Silicate Bonded) CERITE Aluminum (see comments above for Series 8 Tube), molten ferrous and non-ferrous met als, glass processing, kilns, incinerators, and other high temperature pro cess es Aluminum, Zinc IND-6 7-6
7 Ceramic Protection Tubes The thermocouple protection tubes illustrated on this catalog page are replacement tubes for Pyromation's complete ceramic protection tube thermocouple assemblies as found elsewhere in this catalog section, and they are compatible replacements for other manufacturers' protection tubes. The Series 6 mullite tubes are composed of 63% alumina, and have slightly more porosity than the Series 7 alumina tube composed of 99.7% alumina, which is considered to be more gas tight. PIPE NIPPLE E BRASS FERRULE for OPEN STYLE HEAD or NT OPTION HEX FITTING PLAIN or WITH COLLAR ORDER S 2 3 7A Ceramic Protection Tube Materials - Sizes - Fittings TUBE MATERIAL TUBE SIZE COLLAR or FITTING STYLE and MULLITE 482 ºC [2700 ºF] ALUMINA 87 ºC [3400 ºF] ID OD FITTING TYPE - SIZE PROCESS THREAD TERM. THREAD 6AH 7AH /4 3/8 Steel hex fitting /2 NPT /2 NPT 6A 7A /4 3/8 Steel close nipple /2 NPT /2 NPT 6A(E) 7A(E) /4 3/8 Specify "E length" steel nipple /2 NPT /2 NPT 6AF 7AF /4 3/8 7/8" OD x 2" L brass ferrule for open head None 7/8 x 27 UNS 6A 7A /4 3/8 Plain tube None None 6AC N/A /4 3/8 Tube with 5/8" OD x /2" L collar None None 6BH 7BH 7/6 /6 Steel hex fitting 3/4 NPT /2 NPT 6B 7B 7/6 /6 Steel close nipple 3/4 NPT 3/4 NPT 6B(E) 7B(E) 7/6 /6 Specify "E length" steel nipple 3/4 NPT 3/4 NPT 6BF 7BF 7/6 /6 7/8" OD x 2" L brass ferrule for open head None 7/8 x 27 UNS 6B 7B 7/6 /6 Plain tube None None 6BC N/A 7/6 /6 Tube with " OD x /2" L collar None None 6CH 7CH /2 3/4 Steel hex fitting 3/4 NPT /2 NPT 6C 7C /2 3/4 Steel close nipple 3/4 NPT 3/4 NPT 6C(E) 7C(E) /2 3/4 Specify "E length" steel nipple 3/4 NPT 3/4 NPT 6C 7C /2 3/4 Plain tube None None 6CC N/A /2 3/4 Tube w/(/8)" OD x /2" L col lar None None 6WH 7WH 5/8 7/8 Steel hex fitting NPT 3/4 NPT 6W 7W 5/8 7/8 Steel close nipple NPT NPT 6W(E) 7W(E) 5/8 7/8 Specify "E length" steel nipple NPT NPT 6W 7W 5/8 7/8 Plain tube None None 6EH 7EH (/4) Steel hex fitting (/4) NPT NPT 6E 7E (/4) Steel close nipple (/4) NPT (/4) NPT 6E(E) 7E(E) (/4) Specify "E length" steel nipple (/4) NPT (/4) NPT 6E 7E (/4) Plain tube None None 6EC N/A (/4) Tube w/(3/4)" OD x /2" L col lar None None 3 Options 36 SS nipple or 8 hex tube fitting No process mtg. NT threads on pipe nipples 2 Tube Length Specify other lengths in inch increments. 8-5 IND-7
8 Thermocouples with Standard Service Protection Tubes The straight base metal thermocouple assemblies illustrated on this page are those most commonly used in medium to high temperature low corrosion industrial process heating applications. All listed assemblies are provided with schedule 40 protection tubes, and are available with listed options. Heavier pipe schedule protection tubes and special construction designs are also available. ASSEMBLY with WELDED BUSHING ASSEMBLY with OPTIONAL FLANGE ASSEMBLY with OPTIONAL UNION NIPPLE ASSEMBLY with TEMPERATURE CHECK FITTING E ORDER S K8C E20-34 Thermocouple Type + Wire Gauge Size J8C JC J4C K8C KC K4C N8C N4C Thermocouples of 8 ga. wire require min i mum of /2 NPT tube DUPLEX T/C ASSEMBLIES For duplex assemblies use the T/C type code letter twice. Example: K8C becomes KK8C Protection Tube Material 3 NPT Thread Size MATERIAL /4 /2 3/4 6 CARBON STEEL SS SS INCONEL INCONEL Tube Length Specify other lengths in inch increments. Duplex 8,, and 4 ga. as sem blies require a minimum /2" NPT pro tec tion tube size (size codes 50 and larger). 8 gauge duplex thermocouple elements supplied in /2" NPT protection tubes will be supplied with round insulators. 5 Optional Welded Bushings STEEL 36SS BUSHING SIZE 6C(U) 8C(U) /2 NPT Bushing (25 tubes only) 6D(U) 8D(U) 3/4 NPT Bushing (25 and 50 tubes only) 6E(U) 8E(U) NPT Bushing (25, 50 and 75 tubes only) 6F(U) 8F(U) (/4) NPT Bushing 6G(U) 8G(U) (/2) NPT Bushing Substitute insertion length, in inches, measured from hot tip to bottom of bushing for (U) above. Insert NW in place of insertion length (U) for bushing supplied loose on tube. Optional Union and Nipple Head Connection STEEL 36 SS Union-nipple supplied as material specified 6PU(E) [] 8PU(E) [] [] Insert extension length, in inches, for (E) above. 6 Head Terminations 3 Aluminum screw cover head 34 Cast iron screw cover head 49 Flip top aluminum head 7 [] Cast iron aluminum explosion proof head 8 [] 36L SS explosion proof head 9 [] 36L SS head [] Not available with NPT protection tubes. 6- Assembly Options GS Ground screw H Adjustable steel mounting flange I Stainless tag 6Y Steel temperature check fitting L Insulated hot junction IND-8 9-6
9 Thermocouples with Special Service Protection Tubes The straight base metal thermocouple assemblies illustrated on this page are typically used in high temperature and highly corrosive applications commonly found in waste incinerators, cement and lime kilns, utility and waste recovery boilers, and other severe process environments. Special construction designs are also avail able. SERIES 2 ASSEMBLY with " STEEL HEX FITTING STD. Series 2 tubes dimensions are fixed at approximately less than specified length SERIES 4 ASSEMBLY with OPTIONAL FLANGE ASSEMBLY with WELDED BUSHING ORDER S K8C E20-34, I 5- Thermocouple Type + Wire Gauge Size K8C N8C DUPLEX T/C ASSEMBLIES For duplex assemblies use the T/C type code letter twice. Example: K8C becomes KK8C gauge duplex thermocouple elements supplied in 4-50 and 2-75 protection tubes will be supplied with round insulators. 2 Protection Tube Material NPT Connection NPT SIZE HR / / / / LT /4 3 Tube Length Specify other lengths in inch increments. PIPE SCHED OD ID 4 Optional Welded Bushings STEEL 36SS BUSHING SIZE 6D(U) 8D(U) 3/4 NPT Bushing (25 and 50 tubes only) 6E(U) 8E(U) NPT Bushing (50 and 75 tubes only) 6F(U) 8F(U) (/4) NPT Bushing 6G(U) 8G(U) (/2) NPT Bushing Substitute insertion length, in inches, measured from hot tip to bottom of bushing for (U) above. Insert NW in place of insertion length (U) for bushing supplied loose on tube. Optional Union and Nipple Head Connection STEEL 36 SS 6PU(E) 8PU(E) Union-nipple supplied as material specified Insert extension length, in inches, for (E) above. 5 Head Terminations 3 Aluminum screw cover head 34 Cast iron screw cover head 49 Flip top aluminum head 7 [] Cast iron aluminum explosion proof head 8 [] 36L SS explosion proof head 9 [] 36L SS head [] Not available with NPT protection tubes. 5- Assembly Options GS Ground screw H Adjustable steel mounting flange I Stainless tag 6Y Steel temperature check fitting L Insulated hot junction Copyright 2006Pyromation, Inc., All Rights Reserved. 0-6 IND-9
10 Thermocouple Assemblies with Protection Tubes for Molten Aluminum The Series, 3 and 4 assemblies are used to protect thermocouple elements in molten aluminum and zinc applications such as diecasting, melting, smelting and high temperature holding furnace environments. The Series 8 silicon carbide assembly can also be used in the above mentioned applications, however the Series 8 is a refractory silicate bonded tube and generally will not provide a service life equal to silicon nitride bonded silicon carbide assemblies. The Series 8 is satisfactory for use in other molten metals, molten glass, and other high temperature applications. Series 3, 4, and 8 assemblies should be preheated and slowly immersed into any molten materials. SERIES 3 PROTECTION TUBE ASSEMBLIES FIG. SERIES 8J PROTECTION TUBE ASSEMBLIES FIG. 2 SERIES PROTECTION TUBE ASSEMBLIES FIG. 3 SERIES 8JC PROTECTION TUBE ASSEMBLIES FIG. 4 CERITE II 4 PROTECTION TUBE ASSEMBLY FIG. 5 ORDER S K8C , H Thermocouple Type + Wire Gauge Size K8C N8C DUPLEX T/C ASSEMBLIES For duplex assemblies use the T/C type code letter twice. Example: K8C becomes KK8C For additional types and sizes consult factory. 2 Protection Tube Material FIGURE NUMBER CAST IRON VESUVIUS 3-75 SILICON CARBIDE 8J JC-75 4 CERITE II 4-50 [] 5 [] For protection tubes supplied with a 36SS pipe instead of a carbon steel pipe, change order number 4 to 48. EXAMPLE: K8C Protection Tube Dimensions ID x OD x x J.00 x.75 8JC.00 x x Head Terminations 3 Aluminum screw cover head 34 Cast iron screw cover head 49 Flip top aluminum head 9 36L SS head 4- Assembly Options GS Ground screw H Adjustable steel mounting flange I Stainless tag L Insulated hot junction 3 Tube Length [] 48 [] 30 Consult factory for other lengths. [] 42 & 48 not available in 4 Series tubes. IND-0-6
11 Thermocouple Assemblies with Ceramic Protection Tubes The straight noble and base metal thermocouple assemblies, with Series 6 mullite and Series 7 alumina protection tubes, illustrated on this catalog page are those most commonly used in high temperature process heating applications. These assemblies are available with a variety of process mounting fittings and assembly options as listed below. Special construction designs are also available. HEX FITTING PIPE NIPPLE with HT OPTION E PIPE NIPPLE with NT OPTION and FLANGE E OPEN TERMINAL HEAD (OPT. N) ORDER S RR - 7BH - 8-3, 8 Thermocouple Type + Wire Gauge Size BR RR R26R SR S26R 8ga. duplex elements only available in W series tubes. For duplex T/C's, use element type twice. Example: RRR 2 Protection Tube TUBE MATERIAL AND SIZE MULLITE 482 ºC [2700 ºF] ALUMINA 87 ºC [3400 ºF] K8R [] N8R [] [] Use only with 6C or 6W series tubes TUBE OD NPT SIZE KC [2] N4C [2] [2] Use only with 6B or 6C series tubes PROCESS MOUNTING FITTING 6AH [] 7AH [] 3/8 /2 Steel hex fitting 6A [] 7A [] 3/8 /2 Steel close nipple 6A(E) [] 7A(E) [] 3/8 /2 Specify nipple "E" length 6AF [] 7AF [] 3/8 None 7/8" OD x 2" L open head ftg 6BH 7BH /6 3/4 Steel hex fitting 6B 7B /6 3/4 Steel close nipple 6B(E) 7B(E) /6 3/4 Specify nipple "E" length 6BF 7BF /6 None 7/8" OD x 2" L open head ftg 6CH 3/4 3/4 Steel hex fitting 6C 3/4 3/4 Steel close nipple 6C(E) 3/4 3/4 Specify nipple "E" length 6WH 7/8 Steel hex fitting [] All assemblies with a 3/8 OD tube should be ordered with an aluminum termination head. 4 Head Terminations 3 Aluminum screw cover head 34 Cast iron screw cover head 49 Flip top aluminum head 9 36L SS head N 4- Assembly Options GS Ground screw NT No process threads on pipe nipple HT Threaded flange on nipple I Stainless tag 8 36SS nipple or hex tube fitting H Adjustable steel mtg. flange 3 Tube Length Open terminal head - R, S, B only (require AF or BF protection tubes) Specify other lengths in inch increments. 2-6 IND-
12 Thermocouple Assemblies with Double Protection Tubes The straight noble metal thermocouple assemblies illustrated on this catalog page are provided with double protection tubes. Outer protection tube choices of ceramic materials, metal alloys, or composite materials offer thermocouple pro tec tion from a variety of high temperature process heating environments. All assemblies are provided with a ceramic inner tube. These assemblies are available with a variety of process mounting fittings and assembly options as listed below. Spe cial con struc tion de signs are also avail able. FLANGED ASSEMBLY FIG. HEX FITTING FIG. 2 CLAMP ASSEMBLY FIG. 3 WELDED BUSHING FIG. 4 SR ORDER S - 2 6BH-8J , H Thermocouple Type + Wire Gauge Size BR RR SR 2 Protection Tubes (Inner and Outer) MATERIAL TYPE SIZE INNER OUTER O.D. PROCESS MOUNTING FITTING NPT. THREAD FITTING TYPE 7A-7BH Alumina Alumina /6 3/4 Figure 2 7A-7B Alumina Alumina /6 3/4 steel nipple 7A-7B(E) Alumina Alumina /6 3/4 Nipple (specify length) 7A-2-75 Alumina LT- 7/8 Figure 2 7BH-8J Alumina Silicon Carbide (3/4) None Figure 3 7BH-8JC Alumina Silicon Carbide (3/4) None Figure 6A-6BH Mullite Mullite /6 3/4 Figure 2 6A-6B Mullite Mullite /6 3/4 steel nipple 6A-6B(E) Mullite Mullite /6 3/4 Nipple (specify length) 6A-2-75 Mullite LT- 7/8 Figure 2 6BH-8J Mullite Silicon Carbide R26R S26R For duplex T/C's, use element type twice. Example: RRR (3/4) None Figure 3 6BH-8JC Mullite Silicon Carbide (3/4) None Figure 6B-4-75 Mullite HR None Figure 4 6B-7-75 Mullite Inc None Figure 4 The inner protection tubes are cemented to the outer tube and are not re place able as separate items, except for Silicon Carbide assemblies. Optional Welded Bushings (only on HR-60 and Inconel Tubes) STEEL 36 SS BUSHING SIZE 6E(U) 8E(U) NPT Bushing 6F(U) 8F(U) (/4) NPT Bushing 6G(U) 8G(U) (/2) NPT Bushing Substitute insertion length, in inches, mea sured from hot tip to bottom of bushing for (U) above. Insert NW in place of insertion length (U) for bushing sup plied loose on tube. 5 Head Terminations 3 Aluminum screw cover head 34 Cast iron screw cover head 49 Flip top aluminum head 9 36L SS head N Open terminal head - R, S, B only (request AF or BF) 5- Assembly Options GS Ground screw NT No mounting threads on pipe nipple HT Threaded flange on nipple I Stainless Tag 8 36SS nipple or hex tube fitting H Adjustable steel mtg. flange 3 Tube Length Specify other lengths in inch increments. IND-2 3-6
Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5
Thermal Solutions Worldwide SECTION C Industrial Thermocouples and RTDs Straight Base Metal Thermocouple Elements C1 Angle Base Metal Thermocouple Elements C2 Straight Noble Metal Thermocouple Elements
More informationGeneral Information, Industrial Thermocouple Section
INDUSTRIAL THERMOCOUPLES INDEX PAGE General Information... I1 Straight Base Metal Thermocouple Elements (IA)... I2 Angled Base Metal Thermocouple Elements (IB)... I3 Noble Metal Thermocouple Elements (IC,
More informationIndustrial Thermocouples
Industrial Thermocouples Industrial thermocouples are used in high temperature applications, such as those listed below. Several calibrations are available as well as various mechanical configurations.
More informationSTRAIGHT BASE METAL THERMOCOUPLE ELEMENTS
STRAGHT BASE METAL THERMOCOUPLE ELEMENTS Round Element (ront) Bare Element Standard Tig Weld Oval Element (ront) nsulated Element Twisted Weld Oval Duplex Element (ront) Duplex Element Length solated Junction
More informationT/C, Noble, Straight Ceramic
Introduction T/C, Noble, Straight Ceramic Thermocouple, Noble Metal Ceramic Tube, Straight Applications Ordering Information Elements are constructed of high quality material using modern techniques to
More informationThermocouples and Accessories Product Catalog
Thermocouples and Accessories Product Catalog 7282 N. Haggerty Rd. Canton, MI 48187 P. 734-451-8740 / F. 734-451-8741 www.inspec-inc.com 1 P a g e EXPERT CONTROL AND INSTRUMENTATION REPAIR Plastics Industry
More informationAccuTru ExL High Temperature Thermocouples
S E N S O R T E C H N O L O G I E S AccuTru ExL High Temperature Thermocouples Dedicated to those organizations that value improved temperature measurement for critical processes S E N S O R T E C H N
More informationSection 2 Index PAGE 2-I. Metal Sheath and Ceramic Thermocouple Assemblies. AccuTru Sensor Technologies 2-1. Spring Loaded Hex Nipple w/ Head 2-2
Section 2 Index Model Metal Sheath and Ceramic Thermocouple Assemblies Page I1 GTAW Welded Hex Nipple w/ Head 2-1 I2 Spring Loaded Hex Nipple w/ Head 2-2 I3 Spring Loaded Pipe Nipple w/ Head 2-3 I4 Nipple-Union-Nipple
More informationThermocouple Quick Reference Guide. Aluminium Temperature Sensing Solutions from the Smelter to the Foundry
Thermocouple Quick Reference Guide Aluminium Temperature Sensing Solutions from the Smelter to the Foundry why pyrotek? Pyrotek is a global engineering leader and innovator of technical solutions, integrated
More informationMGO INSULATED THERMOCOUPLES INDEX
MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,
More informationIndustrial Thermocouples
Website: Industrial Thermocouples Thermo Sensors Industrial thermocouples are widely used in process industry applications. Thermocouples are generally selected by determining the particular conditions
More informationIndustrial Thermocouples
Industrial Thermocouples Address: Phone:Toll Free: Website: Thermo Sensors Industrial thermocouples are widely used in process industry applications. Thermocouples are generally selected by determining
More informationSheathed Thermocouple Sensor (120 Series)
Applications 120 series comprise a thin-walled and felxible mineral insulated sheath cable made of stainless steel or inconel. The cable contains thermal wires embed in pressed fireproof manesium oxide.
More informationTHERMOWELL ASSEMBLIES & THERMOWELLS INDEX
THERMOWELL ASSEMBLIES & THERMOWELLS INDEX PAGE General Information & Part Numbering Examples... T2 RTD & T/C Style Thermowell Assemblies RTD'S for Thermowells (RT, RV, R4, RW, R1, R2, R5, or R8)... T3
More informationSANDELIUS INSTRUMENTS, INC.
SNDEIUS INSTRUMENTS, INC. To order any style on this page see below: Sandelius Style H Nipple-Union-Nipple (For spring-loading, insert an S in front of the style number) MET SHETHED OR INSUTOR TYPE EEMENT
More informationMetal Transitions HIGH TEMPERATURE
Metal Transitions High Temperature Thermal Solutions of Texas continues to meet the demands of technological advances by developing thermocouples using materials with unusually high performance characteristics
More informationResistance Temperature Detectors (RTD)
Resistance Temperature Detectors (RTD) Style H Connection Head Assembly Connection Head Option A - Aluminum Tip Style F - Flat Tip Head Fitting Option G - ½ NPT Hex Nipple Head Fitting Option A - Fixed
More informationOverview. A thermocouple assembly generally has four major components:
Introduction Several methods of temperature measurement and control have been developed over the years. Industrial process control usually requires that the temperature sensing device must be remote from
More informationThermal Solutions Worldwide SECTION M. Technical Information. Thermocouple Material Specifications M-1. Thermocouple Initial Material Tolerances M-2
Thermal Solutions Worldwide SECTION M Technical Information Thermocouple Material Specifications M-1 Thermocouple Initial Material Tolerances M-2 Thermocouple Colour Codes M-3 Resistance Temperature Detector
More informationINDUSTRIAL TEMPERATURE SENSORS
Temperature s INDUSTRIAL TEMPERATURE SENSORS Temperature s APPLIED SENSOR TECHNOLOGIES A DIVISION OF UNITED ELECTRIC CONTROLS T E M P S E N S O R - B - 0 2 Temperature s Temperature s index Subject Page
More informationIndustrial Process Thermocouples
s ASE ETAL PROTECTION TUE ASSELY The TPT Style assemblies feature a base metal thermocouple and metal protection tube for use in corrosive or hostile environments. Optional mounting bushings and flanges
More informationPFA (Fluororesin) coated temperature sensors
PFA (Fluororesin) coated sensors FT-100 () FR-100 (Resistance Temperature Detecr) Temperature sensor with perfluoroalkoxy polymer resin coating (PFA) excels in chemical and moisture resistance. Measuring
More informationThermocouple Reference Table
Thermocouple is the description for electrical feedthroughs that are commonly used for temperature measurement systems. A thermocouple feedthrough does not measure temperature, but rather it is used to
More informationSANDELIUS INSTRUMENTS, INC.
SNDEIUS INSTRUMENTS, INC. To order any style on this page see below: Sandelius Style H Nipple-Union-Nipple (For spring-loading, insert an S in front of the style number) MET SHETHED OR INSUTOR TYPE EEMENT
More information5. SHEATH MATERIALS, THERMOWELLS, FITTINGS AND TERMINATIONS
. SHEATH MATERIALS, THERMOWELLS, FITTINGS AND TERMINATIONS Temperature sensor elements for laboratory and industrial use, whether Pt100 or thermocouple will normally be protected by some form of sheath
More informationGeneral Purpose Thermocouples
General Purpose Thermocouples Style GP Rigid Tube Assembly T G P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1. Calibration (See page 13 for other Cals) J = Type J (1400 o F) T = Type T (700 o F) K = Type K
More informationGeneral Purpose Thermocouples
General Purpose Thermocouples Style IW Insulated Wire Assembly A Leadwire Construction Option A - Solid Fiberglass Termination Option T - Split Leads A Special Option T - Acid Resistant Teflon Sealed Tip
More informationMineral Insulated (MgO) Thermocouples
Option F - Flat Tip Head Fitting Option G - ½ NPT Hex Nipple Connection Head Option A - Aluminum Mineral Insulated (MgO) Thermocouples Option F - Flat Tip Head Fitting Option G - ½ NPT Hex Nipple Style
More informationInfinite Thermal Solutions Inc. Thermocouples and RTDs
Thermocouples and RTDs Page 120 T121 R121 T221 R221 T122 R122 T12 R12 T22 R22 T222 R222 ORDERING INFORMATION - 1 2 4 5 6 7 8 9 10 11 12 1 14 15 16 Type T = Thermocouple 04 Stainless Steel Protection Tube
More informationThermocouple Reference Table
Thermocouple is the description for electrical feedthroughs that are commonly used for temperature measurement systems. A thermocouple feedthrough does not measure temperature, but rather it is used to
More informationMineral Insulated (MgO) Thermocouples
Mineral Insulated (MgO) Thermocouples Style F Transition Assembly E (4 std) T F 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1. Transition (See page 18 for more transitions) A = Standard Transition w/relief
More informationTable of Contents PAGE
Table of Contents Thermocouple Wire Data 2 Ordering Information 3 Noble Metal Thermocouples 4 Noble Metal Elements NME 4 Noble Metal Assemblies NMA 5 Ceramic Protection Tubes CPT 6 Silicon Carbide/Composite
More informationA thermocouple assembly generally has four major components:
Introduction Several methods of temperature measurement and control have been developed over the years. Industrial process control usually requires that the temperature sensing device must be remote from
More informationTHERMOCOUPLE TECHNICAL REFERENCE DATA
THERMOCOUPLE TECHNICAL REFERENCE DATA Thermocouples are temperature sensors suitable for use with any make of instrument designed or programmed for use with the same type of thermocouple. Thermocouples
More informationThermocouples W A T L O W
W A T L O W General Applications Over 90 years of manufacturing, research and design makes Watlow a world class supplier of temperature measurement products. We have designed and manufactured millions
More informationIndustrial Thermocouples
Industrial Thermocouples Protection Head Design U Sheath Materials: 304SS, 30SS, 36SS, 32SS, Inconel or Super OMEGACLAD XL U Probe Length 300 mm (2"), 600 mm (24") Custom Lengths Available, Consult Sales
More informationResistance Temperature Detectors
Resistance Temperature Detectors INTRODUCTION For high-accuracy temperature measurements in a variety of industrial and commercial air and gas applications, Durex Industries offers RTD s of multiple elements
More informationThermocouple for Flue Gas Temperature Measurements,
Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and
More informationAccuTru Sensor Technologies
High Temperature ExL Ceramic Sheathed Thermocouples NEW TECHNOLOGIES (exclusively from AccuTru) Mi-Dry, ExL, SVS AccuTru is becoming well known in the process control community as a leading edge sensor
More informationTHERMOCOUPLE TECHNICAL REFERENCE DATA
THERMOCOUPLE TECHNICAL REFERENCE DATA Thermocouples are temperature sensors suitable for use with any make of instrument designed or programmed for use with the same type of thermocouple. Thermocouples
More information6. SHEATH MATERIALS, THERMOWELLS, FITTINGS, AND TERMINATIONS
6.1 INTRODUCTION: 6. SHEATH MATERIALS, THERMOWELLS, FITTINGS, AND TERMINATIONS Temperature sensor element for laboratory and industrial use should normally be protected by some form of sheath or housing.
More informationTHERMOMETERS. STANDARD BIMETAL 90 back angle type available in 2, 3 and 5 dials
THERMOMETERS Thermometers are used to measure temperature. PIC stocks a variety of temperature measuring instruments, including bimetals, magnetic thermometers, tridicators and scale thermometers. STANDARD
More informationTWF11, TWF16. Technical Information. Metal or ceramic thermowells For high temperature assemblies TAF11 and TAF16 Adjustable process connection
Technical Information TWF11, TWF16 Metal or ceramic thermowells For high temperature assemblies TAF11 and TAF16 Adjustable process connection Application TWF11 Applicable for steel treatment (annealing),
More informationThermocouples for Ultra High Temperature Technologies
Thermocouples for Ultra High Temperature Technologies Tungsten Coated Probes Operating Temperatures up to 4200F (2315C) Molybdenum and tantalum tungsten coated sheaths Refractory Metal, Inconel, or Stainless
More informationResistance Temperature Detectors
PRODUCT REFERENCE GUIDE Probes & Assemblies PRODUCT FEATURES Rugged Construction Accurate and Stable Probes General Purpose, Tip Sensitive, High Temperature and High Vibration Probes and Assemblies 2,
More informationCosasco Retractable System (Intermediate Pressure Access)
Cosasco Retractable System (Intermediate Pressure Access) COSASCO RETRACTABLE SYSTEM MODEL 6 Features Quick Mounting & Release Simple to Operate Lightweight 5 PSI Working Pressure Convenient Carrying Case
More informationE (4 std) (1/4 std) 1. Calibration (See page 13 for other Cals) 3. Junction Grounded Ungrounded
Special Purpose Style LN Adjustable Lockcap Assembly Style S Fixed Bayonet Thermocouple Assembly Style LN Lockcap Armor Assembly Bend Option G - Straight A (4 std) Leadwire Construction Option O - Stranded
More informationTHERMOCOUPLES & RTDS
Since 96 S & RTDS W. H. COOKE & CO., INC. 6868 York Road P. O. ox 89 Hanover, P 7 Information (77) 60- Orders (800) 77-55 Fax (77) 67-9999 Email: sales@whcooke.com Web: www.whcooke.com www.whcooke.com
More informationModel 410 Threaded Straight Thermowell. Model 411 Threaded Tapered Thermowell. Model 412 Threaded Reduced Tip Thermowell 1.
Model 410 Threaded Straight Thermowell 1.75 + T 3/4 NT 0.75 0.75 1 NT 0.875 0.875 Model 411 Threaded Tapered Thermowell 1.75 + T 3/4 NT 0.875 0.625 1 NT 1.063 0.625 Model 412 Threaded Reduced Tip Thermowell
More information7. EXTENSION LEADS AND COMPENSATING CABLE
7. EXTENSION LEADS AND COMPENSATING CABLE 7.1 INTRODUCTION : It is often desirable to connect a thermocouple probe, as a part of a very long circuit from the sensor itself to a remote reference unit and/or
More informationSECTION 2: PROBES. Page 2-1
SECTION 2: PROBES RTDs and thermocouples in a variety of configurations for easy installation Tip-sensitive and fast response probes for quick and accurate temperature sensing High temperature probes to
More informationDescription/Application Maximum Temperature Continuous Firing Maximum Temperature Intermittent Firing Fuel Construction Diameters: Insulation
Description/Application Double wall air or optional fiber insulated positive pressure system for venting boilers, kilns, grease ducts, emergency generators, caustic air, coffee roasters, bagel ovens, bread
More informationRTDs. Offered by. Phone: (203) Fax: (203) Specialists in Valves, Controls, Pneumatics, Fluid Measurement
RTDs Offered by Phone: (203) 261-6711 Fax: (203) 261-8331 www.okcautomation.com Specialists in Valves, Controls, Pneumatics, Fluid Measurement NS RTD s I- Theory of Operation n RTD s basis of operation
More informationResistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier
Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier of temperature sensors and component parts for all industrial applications Manufactured
More informationTemperature Sensor Catalogue
Serving you since 1948 Temperature Sensor Catalogue ISO 9001: 2008 Registered and ISO 17025 Accredited. 6260 Hawthorne Dr, Windsor, On-N8T1J9. Canada. Ph 1-888-4-ISOLAB & 519-948-871 FAX: 519-948- 614
More informationTemperature Measurement
Temperature Measurement Sensing methods: contact and noncontact Temperature sensors generate output signals in one of two ways: 1. through a change in output voltage 2. through a change in resistance of
More informationSENSOR CATALOG STANDARD AND CUSTOM DESIGN / IN-HOUSE MANUFACTURE
CATALOG STANDARD AND CUSTOM DESIGN / IN-HOUSE MANUFACTURE Spring Loaded Type Fixed Insertion Direct Mounting Oil Tight Removable Bearing Type Standard Industrial with Plug Connection Multipoints Weld Pad
More informationS E C T I O N 3 : P R O B E S
S E C T I O N 3 : P R O B E S RTDs and thermocouples in a variety of configurations for easy installation Tip-sensitive and fast response probes for quick and accurate temperature sensing High temperature
More informationPlatinum Resistance Thermometer (PRT) Selection Guide
Platinum Resistance Thermometer (PRT) Selection Guide hken.rs-online.com (Hong Kong (English)) www.rs-components.com (International) Thermocouple & Platinum Resistance Thermometry - At A Glance Discover
More informationThermocouple Heads. MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model No.) B-9 76 (3) Model Price Material Type Number Each 48 (1 7 8)
Thermocouple Heads Dimensions: mm (in) MOST POPULAR MODELS HIGHLIGHTED! Model Price Material Type Number Each 48 ( 7 8) (3 3 8) 54 (2 8) NB-0 $23 Cast Iron NB NB-2 26 NB-4 28 92 (3 5 8) NB Cast Iron NB4
More informationIndustrial Process Thermocouples
Industrial Process s INTRODUCTION Durex Industries manufactures a wide selection of industrial process thermocouples to meet the requirements of the most demanding process applications in the world such
More information02 Our Mission. 05 Letter From The President. 06 Company Overview. 08 Speed...Beyond Measure. Speed, Service, Solutions Beyond Measure
02 Our Mission 05 Letter From The President 06 Company Overview Speed, Service, Solutions Beyond Measure Our mission is to provide solutions to manufacturers worldwide, improving their ability to safely
More informationOPERATING MAINTENANCE INSTRUCTIONS
System OPERATING MAINTENANCE INSTRUCTIONS Thermocouples are the most widely used temperature sensors. They are low cost, interchangeable, robust and can measure a wide range of temperatures. Thermocouples
More informationD.0. Thermocouple. Introduction
D.0 Introduction Description s are widely used to measure the temperature inside a vacuum or pressure chamber. CeramTec s thermocouple feedthroughs, manufactured with thermocouple materials or compensating
More informationCD Capacitor Discharge The Process
CD Capacitor Discharge The Process. CD. Capacitor Discharge Why CD Studs are better CD. Capacitor Discharge General Specifications Weld Base: CD. Stud Load/Torque Strengths Stud Material Stud Size Maximum
More informationThermocouple cable and assemblies ENCLAD
Thermocouple cable and assemblies ENCLAD ENCLAD thermocouples Introduction BASF ENCLAD thermocouple products are a precise and rigorously controlled combination of select precious and base metal sheaths,
More informationD.0. Thermocouple. Introduction
D.0 Introduction Description s are widely used to measure the temperature inside a vacuum or pressure chamber. CeramTec s thermocouple feedthroughs, manufactured with thermocouple materials or compensating
More informationSANDVIK 253 MA TUBE AND PIPE, SEAMLESS
SANDVIK 253 MA TUBE AND PIPE, SEAMLESS TIETOLOMAKE Sandvik 253 MA is an austenitic chromium-nickel steel alloyed with nitrogen and rare earth metals. The grade is characterized by: High creep strength
More informationISO 9001:2008 certified
c ISO 9001:2008 certified 3/14 www.setexproducts.com INTRODUCTION SETE Thermowells serve two primary functions: (1) extend temperature instrument life by protecting sensing elements from harsh process
More informationBase Models: 1-22SV Major Components GOULDS PUMPS. Commercial Water
Base Models: 1-22SV Base Models: 1-22SV F, P, R VERSIONS 1 Pump Body Stainless Steel AISI 304 EN 10088-1-X5-CrNi-10 (1.4301) 2 Impeller Stainless Steel AISI 304 EN 10088-1-X5-CrNi-10 (1.4301) 3 Diffuser
More informationTHERMOCOUPLE AND EXTENSION GRADE BARE WIRE
THERMOCOUPLE AND EXTENSION GRADE BARE WIRE This Section Contains Tables by Calibration Reference Data If you can t find what you need CALL!! Phone 618-465-7623 Fax 618-465-7679 E-mail www.info@ipscustom.com
More informationSESAsensors INDUSTRY PRODUCTS PRIMARY ELEMENTS FOR TEMPERATURE MEASUREMENTS THERMOCOUPLES THERMORESISTANCES PROTECTION SHIELDS
SESAsensors Via del Tratturello Tarantino, 6 c/o CISI PUGLIA 74100 - TARANTO INDUSTRY PRODUCTS PRIMARY ELEMENTS FOR TEMPERATURE MEASUREMENTS THERMOCOUPLES THERMORESISTANCES PROTECTION SHIELDS n 0 7 1 5
More informationAccessories. Accessories. Parker Autoclave Engineers offers a complete selection of accessories to complete your system requirements.
Accessories Parker Autoclave Engineers offers a complete selection of accessories to complete your system requirements. Components such as thermocouples and thermowells are used for monitoring and controlling
More informationWill accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages
H.0 Accessories Introduction Description Accessories is the product classification given by CeramTec for miscellaneous hardware that is used to connect, terminate, install, or isolate Ceramaseal products.
More informationTemperature Measurement with the Expendable Immersion Thermocouple
Temperature Measurement with the Expendable Immersion Thermocouple A SURVEY OF WORKS EXPERIENCE By J. A. Stevenson, B.s~. Platinum Development Department, Johnson Matthey & Co Limited The expendable immersion
More informationWill accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages
H.0 ACCESSORIES Introduction Technical Reference Accessories Pressure Viewport Isolator Thermocouple Coaxial Multipin Connector Feedthrough Description Accessories is the product classification given by
More informationAccessories. Page. Fittings. Thermowells. Protection Tubes. Connectors. Connection Heads and Blocks Transmitters. Accessories WATLOW
Product Fittings Thermowells Protection Tubes Connectors Connection Heads and Blocks Transmitters Description A variety of sensor mounting fittings are available such as fixed, adjustable, non-adjustable,
More informationWater & Industrial Products Catalog
Water & Industrial Products Catalog www.smith-blair.com info@smith-blair.com Phone: 800..9705 or 870.77.527 After Hours Number: 90.277.998 Fax: 800.8.792 or 870.77.52 EMERGENCY PHONE 90.277.998 In the
More informationPRODUCT LIST (REFRACTORIES)
PRODUCT LIST (REFRACTORIES) For IRON & STEEL INDUSTRY Coke Oven Silica Bricks Mullite, Mullite-silicon Carbide Bricks for Dry Quenching Fire Clay Bricks Hot Blast Stove Silimanite-Mullite & Andalusite
More informationThermocouples Straight Design Model TC501, for Flue Gas Measurement
Electrical Temperature Measurement Thermocouples Straight Design Model TC501, for Flue Gas Measurement WIKA Data Sheet TE 65.30 Applications T Blast furnaces, air heaters T Red-heat and heat treatment
More informationTable of Contents - Thermocouples & RTD's
REOTEMP Instrument Corporation Table of Contents - & RTD's Head ssemblies... pp. 3,4,5 Stem ssemblies... p. 6 Lead Wire Configuration... p. 7 Metal Tube ssemblies... p. 8 Ceramic Tube. p. 9 Replacement
More informationThermocouple Theory & Development
Thermocouple Theory & Development I THE THERMOCOUPLE A thermocouple is composed of two dissimilar metals, usually in wire form, joined together at one end to form the measuring or "hot" junction, while
More informationAccessories. Accessories. Autoclave Engineers offers a complete selection of accessories to complete your system requirements.
Accessories Autoclave Engineers offers a complete selection of accessories to complete your system requirements. Components such as thermocouples and thermowells are used for monitoring and controlling
More informationTemperature Measurement SITRANS TS500
Overview emperature sensors of the product family are used to measure temperatures in industrial equipment. Benefits he modular design makes it possible to customize the temperature sensor for most applications,
More informationlength i.e. the length required to pass through walls, pipe fittings, etc. is taken into account when choosing the necessary insertion length.
www.tcproducts.com ---5 hermo-ouple Products o. hermo-ouple Products company offers thermowell assemblies in a wide variety of materials, lengths and diameters to meet your particular application conditions
More informationFire Clay Brick. Pyrophylite Brick. Pyrophylite -SiC-C brick. Pyrophylite -SiC brick. High Alumina Brick. Alumina-SiC-C Brick.
Fire Clay Brick Pyrophylite Brick Pyrophylite -SiC-C brick Pyrophylite -SiC brick High Alumina Brick Phosphate unbuned High alumina Brick Mullite brick for dry quenching device Alumina-SiC-C Brick Silica
More informationInnovative Temperature Measurement in Heat Treatment Processes
Thermo Sensor GmbH Carl-Zeiss-Straße 1 59368 Werne Germany Tel.: +49 2389-40200-0 Fax: +49 2389-40200-99 www.thermo-sensor.de info@thermo-sensor.de Innovative Temperature Measurement in Heat Treatment
More informationAvailable J, K, T, E, R, S, J, K, T, E J, K, T, E J, K, T, E J, K, T, E J, K, T, E, N
Thermocouple Series No. Unsheathed T/C 5TC/5SRTC 5SC SA1 CO1 Bare, SH, DH, FS Page No. A-15 A-19 A-23 A-25 A-26 A-28 Price $17 pkg of 5 $33 pkg of 5 $58 pkg of 5 $60 pkg of 5 $17 $6 Configuration Fine
More informationRed Dot. Rigid Fittings. Table of Contents
Table of Contents Conduit Unions Hazardous Locations... C2 C3 Conduit Fittings Hazardous Locations... C4 C5 Sealing Fittings Hazardous Locations... C6 C7 Conduit Hubs Raintight for Threaded Rigid Conduits...
More informationSTAINLESS STEEL SHEETS
STAINLESS & NICKEL ALLOY CHATHAM STEEL CORPORATION 59 STAINLESS STEEL SHEETS TYPE 04, 04L, 6, 6L No. 2B Finish Cold Rolled, Annealed *No. 2D Finish No. Finish Polished One Side No. 4 Finish Polished One
More informationD-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves
TAPPING VALVE MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D. PVC--Also outlet sealed
More informationW A T L O W. Application. Over 704 C (1300 F) Carburizing hardening. Inconel 600, Type 446 SS. Hot blast main Inconel 600 Stove trunk Inconel 600
Inconel and Monel are registered trademarks of the Special Metals Corporation. Hexoloy is a registered trademark of Carborundum Company. Hastelloy C is a registered trademark of Haynes International. Heat
More informationModel B. Thermostatic Control Valves. Typical applications
Thermostatic Control Valves Model B Typical applications Lubricating oil temperature control Jacket water high temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications
More informationUTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters
UTECO Temperature Probes Overview Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters About us UTECO S.A has 45 years experience in designing and manufacturing of a
More informationSURFACE TEMPERATURE SENSORS
SURFACE TEMPERATURE SENSORS These sensors are thermocouples and resistance thermometers for surface temperature measurement of objects. C400 R400 Magnet sensors measurement and monitoring of objects such
More informationBI-METAL DIAL THERMOMETERS
T +6 (4) 2231 0059 F +6 (4) 2236 0236 Rm. 103-A, No. 67, T +6 (21) 5777 310 F +6 (21) 5777 319 BI-METAL DIAL THERMOMETERS 2. Case Dial 4. Connec on 5. Stem Dial 6. Stem Length 60 70 0 90 R 1 50 40 32 F
More informationt y p e V S A S E W A G E P U M P
Pe r fo r m a n ce C h a r t 65 6 55 45 4 35 3 25 2 12 11 1 / 2 11 1 1 / 2 1 9 1 / 2 6% 7% 76% 7 1 HP 1/2 HP HP 76% 7% 6% C u r v e P a g e V S A - 5 1 1 5 R P M M O D E L : V S A - 6 H D I S C H A R G
More informationANSI and IEC Color Codes for Thermocouples, Wire and Connectors
ANSI and IEC Col Codes f Thermocouples, Wire and Connects Thermocouple Wire, Probes and Connects are available with either ANSI IEC Col Codes. In this Handbook, model numbers in the To Order tables reflect
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS
SPRING LOADED THERMOCOUPLE CONFIGURATIONS FOR USE WITH THERMOWELLS II 3G Ex na/nl TCRN/WN/TN S30 S31 S36-1 S36-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration guarantees
More information+91-8071803871 Maharashtra Metal (India) http://www.maharashtrametal.co.in/ Maharashtra Metal (India) is a trusted firm engaged in manufacturing and exporting a commendable range of Ferrous and Non Ferrous
More information