Mechanical Connectors Product Overview

Size: px
Start display at page:

Download "Mechanical Connectors Product Overview"

Transcription

1 Product Overview Split-Bolt Connectors Service Post Connectors Mechanical Service Entrance Connectors Parallel Groove Connectors Insulated Conductor Connectors Two-Bolt Connectors Cross Tap Clamps/Dead End Clamps Hot Line Clamps Multi-Bolt Connectors MT Connectors Copper Mechanical Connectors nti-rotational Connectors Dual-Rated Mechanical Connectors Miscellaneous Hardware Locktite Connectors Tap Connectors for Code Copper Conductors

2 Mechanical Connectors Product Overview Type H, HPS, HPW Copper Split Bolt Connectors Pages 4-42 Type PS, W, C luminum Split Bolt Connectors Pages 4-44 Type SP Split Bolt Pages 4-46 Type N, NPW Service Entrance Connectors Page 4 Type MS Neutral Span Clamp Page 4 Blackburn ViceLock Page 48 Type PC, PE, PC, K Parallel Groove Connectors Pages 4- Type IPC Insulation Piercing Connectors Page 2 Type PT Insulated Phase Line Connectors Page 2 Type 2B, 2BX, 2BW Two-Bolt Connectors Pages -4 Type XT Cross Tap Clamp Page Type DLC Dead-End Clamps Page Type HLC, PGH Hot Line Clamps Page Type 4B, 6B Multi-Bolt Connectors Page MT Connectors Page 8 Type L, TL Copper Mechanical Connectors Pages -60 Type S Copper Splice Page 60 Type STC, BTC Copper Mechanical Connectors Page 6 Type DR Dual-Rated Mechanical Connectors Pages Type SL Dual Rated Mechanical Connectors Pages 6-68 Type SR Splicer Reducer Page 6 Type BX Rectangular Connectors Page 6 Type GP, GT luminum Parallel Tap Connectors Page 0 Type TC Insulating Covers Page Type BB, HN, SW Silicon Bronze Hardware Page 2 LOCKTITE Connectors Pages -80 Tap Connectors Page Thomas & Betts Corporation. Specifications are subject to change without notice.

3 Split Bolt Connectors or copper to copper connections. Bolt and nut of high strength corrosionresistant bronze alloy. Pressure bar is copper through 40H; copper alloy is used for 0 kcmil and above. Bolt and nut of hex design up to 0 kcmil. Tested and Listed to U.L. 486 requirements. Type H High Strength Split Bolt Connectors (WG or kcmil) Range for Min. Tap Equal Main with One Cat. No. and Tap Max. Main B C D H 0 str. 2 sol. 4 sol H 8 str. 0 sol. 4 sol H* 8 str. 2 sol. 6 str H 6 sol. 8 sol. 4 sol H* 6 sol. 0 sol. 6 str H 4 sol. 8 sol. 4 sol H* 4 sol. 8 sol. 6 str..2 2 H sol. 8 sol. 6 str H* 4 str. 8 sol. 6 str H 2 sol. 6 sol. 4 sol H* 2 sol. 6 sol. 4 sol..2 2 H 2 str. 6 sol. 4 sol. 6.0 H** 2 str. 6 sol. 4 sol H /0 str. 4 sol. 4 sol H 2/0 str. 2 sol. 4 sol H 4/0 str. 2 sol. 6 sol H 20 kcmil str. 8 sol M 0 kcmil 20 kcmil /0 str M 00 kcmil 400 kcmil 2/0 str M 0 kcmil 600 kcmil 4/0 str M 000 kcmil 800 kcmil 4/0 str * Will accommodate wires of maximum size. ** Will accommodate #2 str. wires. The H bolts are not U.L. Listed or CS Certified. U.L. recognizes solid and stranded conductor configurations for sizes #8 and smaller and stranded configurations only for sizes #6 and larger. Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 4

4 Mechanical Split Bolt Connectors Blackburn or use on copper, aluminum and CSR conductors. Most connectors are U.L. Listed and CS Certified for copper conductor only. Bolt and pressure bar of copper alloy completely tin plated. Contoured spacer of electrolytic copper up through 4/0; bronze alloy 0 and above, all tin plated. Blackburn Contax recommended when used on aluminum conductor. Type HPS Plated Split-Bolt Connectors with Spacer (WG or kcmil) Range for Range for Min. Tap Equal Main Equal Main with One and Tap and Tap Max. Main Cat. No. CSR Copper or luminum B C D HPS 0 str. 2 sol. 2 sol HPS 8 str. 2 sol. 2 sol HPS 8 6 sol. 2 sol. 2 sol HPS sol. 2 sol. 2 sol HPS sol. 8 sol. 8 sol..2 2 HPS 2 8 str. 8 sol. 8 sol HPS 6 /0 str. 6 sol. 6 sol HPS /0 6 2/0 str. 6 str. 6 sol HPS 4/0 4 4/0 str. 4 sol. 4 sol HPS /0 0 kcmil /0 str. 2 sol HPS*. /0 00 kcmil /0 str. /0 str HPS* /0 0 kcmil 4/0 str. 2/0 str HPS* kcmil 00 kcmil 4/0 str * Not CS Certified. U.L. 486 or use on combinations of copper, aluminum and CSR conductors. Bolt and pressure bar of high strength copper alloy completely tin plated; spacer and washer of electrolytic copper up through 4/0; bronze alloy 0 and above, all tin plated. Contoured spacer and bell mouth washer distributes pressure over large area of conductor. Large contoured spacer provides wide separation between copper and aluminum conductors. Blackburn Contax recommended when used with aluminum conductor. Type HPW Plated Split-Bolt Connectors with Spacer and Washer (WG or kcmil) Range for Range for Min. Tap Equal Main Equal Main with One and Tap and Tap Max. Main Cat.No. CSR Copper or luminum B C D 6HPW 8 6 sol. 2 sol. 2 sol HPW sol. 2 sol. 2 sol HPW sol. 8 sol. 8 sol..2 2 HPW 2 8 str. 8 sol. 8 sol HPW 6 /0 str. 6 sol. 6 sol HPW /0 6 2/0 str. 6 sol. 6 sol HPW 4/0 4 4/0 str. 4 sol. 4 sol D C B Thomas & Betts Corporation. Specifications are subject to change without notice.

5 Split Bolt Connectors ccommodates all aluminum and copper conductor combinations. 6 bolts cover the range from #0 to 4/0 WG. Can be installed with standard wrenches. Corrosion resistant tin plated aluminum. Tested and listed to U.L. 486B, 0 C requirements. Type PS luminum Dual-Rated Split Bolts Cat. No. Equal Main & Tap B C D E PS str PS str PS str 6..6 PS /0-4 str PS2 2/0-4 str PS4 4/0-2 str PS0* 0 kcmil-4 str PS00* 00 kcmil-2 str * Square head design not CS certified Blackburn or all aluminum applications. Bolt, nut, pressure bar and contoured spacer of aluminum alloy. Large contoured spacer gives wide separation. Nut anodized to prevent thread galling. Blackburn Contax recommended when used on aluminum conductor. Type W luminum Split-Bolt Connectors with Spacer and Washers (WG) Range for Range for Min. Tap Equal Main Equal Main with One and Tap and Tap Max. Main Cat. No. CSR luminum B C D 6W sol. 8 sol. 0 sol W sol. 8 sol. 8 sol W 2 8 str. 8 sol. 8 sol. 6.0 W 4 /0 str. 2 sol. 4 sol W /0 4 2/0 str. 2 sol. 4 sol W 4/0 4 4/0 str. 4 sol. 4 sol Thomas & Betts Corporation. Specifications are subject to change without notice. 4

6 Split Bolt Connectors Blackburn Bolt, nut and washer of high-strength aluminum alloy; pressure bar and contoured spacer of electrolytic copper. Spacer is completely tin plated. Bolt and nut are anodized to prevent seizing of threads and reduce galvanic corrosion when in contact with copper conductor. Contoured spacer and bell mouth washer distributes pressure over large area of conductor. Blackburn Contax recommended with this Connector. Type C luminum Split-Bolt Connectors with Spacer and Washer (WG) Range for Min. Tap Equal Main with One and Tap Max. Main Cat. No. Copper or luminum B C D 6C 4 sol. 6 sol. 4 sol. 2 sol C 2 sol. 4 sol. 2 sol. 0 sol C str. 4 sol. str. 8 sol. 6.0 C /0 str. 2 sol. /0 str. 6 sol C 2/0 str. 2 sol. 2/0 str. 6 sol C 4/0 str. 2/0 sol. 4/0 str. 4 sol Thomas & Betts Corporation. Specifications are subject to change without notice.

7 Service Post Connectors pplication The Blackburn line of Service Post Connectors is designed for applications including steel structure, fence post or transformer grounding involving one or two cables. Service Posts can also be used to tap one or two cables from bus bar. Construction and Ratings Bolts used in the Service Post are machined from high conductivity bronze alloy while the nuts are coldformed from high strength, corrosion resistant copper alloy. Pressure bars are copper through 4/0 size, while copper alloy is used for 0 mcm size and above. Bolts and nuts are of the traditional Blackburn hex design for easy installation. Service Post Connectors are available in sizes accommodating WG copper conductor ranges of #2-00 kcmil stranded (4mm2-240mm2) and #2-#2 solid (4mm2-mm2). The line includes single conductor and double conductor connectors. or copper to copper connections. or grounding of steel structures, fence posts, transformers using one or two cables. or tapping one or two cables from bus bar. Hex design bolts are machined from high conductivity bronze alloy. Nuts and pressure bars are coldformed from high-strength copper or copper alloy. U.L. 486 and U.L. 46 Listed. Single and Double Conductor Short Stud WG mm 2 Maximum Diameter Stranded Solid Range Cat. No. max. min. max. min. (in.) SP-S SP-D Stud Size B C D E SP0DS SP0SS 20 x 6 6 4mm 2 0mm 2 4mm SPDS SPSS 20 x 6 2 0mm 2 6mm 2 0mm 2 6mm SP2DS SP2SS 6 8 x 6 2 6mm 2 6mm 2 6mm 2 6mm SPDS SPSS 6 x 6 2 2mm 2 6mm 2 mm 2 6mm SP4DS SP4SS 6 x mm 2 6mm 2 mm 2 0mm 2 / SPDS SPSS x 6 0mm 2 mm 2 mm 2 2/ SP6DS SP6SS x 6 6 0mm 2 mm 2 mm 2 4/ SP8DS SP8SS x mm 2 mm 2 0 /0.-. SPDS SPSS x mm 2 0mm 2 00 / SP0DS SP0SS 0 x 2 240mm 2 mm 2 Blackburn Single Conductor Short Stud Double Conductors Short Stud 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 4

8 Service Post Connectors Single and Double Conductor Long Stud WG mm 2 Maximum Diameter Stranded Solid Cat No. Range max. min. max. min. (in.) SP-S SP-D Stud Size B C D E Blackburn SP0SL SP0DL 20 x 6 6 4mm 2 0mm 2 4mm SPSL SPDL 20 x 6 2 0mm 2 6mm 2 0mm 2 6mm SP2SL SP2DL 6 8 x 6 2 6mm 2 6mm 2 6mm 2 6mm SPSL SPDL 6 x 6 2 2mm 2 6mm 2 mm 2 6mm SP4SL SP4DL 6 x mm 2 6mm 2 mm 2 0mm 2 / SPSL SPDL x 6 0mm 2 mm 2 mm 2 2/ SP6SL SP6DL x 6 6 0mm 2 mm 2 mm 2 4/ SP8SL SP8DL x mm 2 mm 2 0 /0.-. SPSL SPDL x mm 2 0mm 2 00 / SP0SL SP0DL 0 x 2 240mm 2 mm 2 Single Conductor Short Stud Double Conductors Short Stud Thomas & Betts Corporation. Specifications are subject to change without notice.

9 Mechanical Service Entrance Connectors Types N and NPW Service Entrance Connectors (WG) CSR Copper Cat. No. max. min. max. min. B C H Bolt Head Service entrance connectors with bodies and screws of high-strength copper alloy; NPW is tin plated. Type NPW has phosphor bronze washer, tin plated to protect conductor and distribute pressure. Type NPW can be used on CSR conductor Slotted hex head screw. 0N 0NPW 0 str. 4 sol N 6NPW str. 0 sol N 4NPW str. 6 sol NPW str. 6 sol Type N Type NPW Washer on Type NPW only Blackburn Type MS Neutral Span Clamp CSR WG Cat. No. Main Tap Main Tap MS4 4/0 4 /0 6 4/0 str. 2 sol. /0 str. 6 sol. combination aerial cable neutral parallel groove connector and dead-ending clamp that accommodates up to four service drops. Used in situations where house is not adjacent to pole. Taps may be installed later independent of existing connections. Castings are of high strength aluminum alloy; hardware is galvanized steel; one piece construction Thomas & Betts Corporation. Specifications are subject to change without notice. 4

10 Parallel Groove Connectors ViceLock NEW Blackburn GET GRIP! With our new bronze vise type connectors that come in numerous sizes and offer a wide variety of features which will save you time and money. Blackburn Bronze ViseLock Connectors Create a superior electrical connection. Eliminate the need for costly or heavy tools. Install fast and easy. Make a permanent connection. Easily installed with live line tools. dvantages Vibration resistant. Easy to install without crossthreading. V-Grooves for easy conductor alignment. Increased bolt strength due to a full thread engagement design. The high pressure - torque ratio assures a low electrical resistance connection. Helps to reduce your inventory by accepting a wide range of conductors. Specification Information Bellcore pproved. Silicon Bronze material (CD6000) for higher yield strength. Offer Stainless Steel hardware for large sizes. Superior Electrical Performance. NSI Standards. ocus pplications Distribution Loads. Service Bonding. Tap Connections. Ground Connections. lso has a grounding capability with a variety of Cable Tray, Channel and Strut applications. Cross Reference Information Blackburn 2 Conductors Wire Range* Inner Ctn. Master Ctn. Competitor Cross Ref. Cat. No. Max. Min. Decimal (in.) Qty. Qty. RGO RELIBLE VGC68 #6 SOL #0 SOL GC-006 BVC-6 VGC68SH #6 SOL #0 SOL GC-006SH VGC44 #4 STR. #8 SOL GC-004 BVC-4 VGC2 #2 SOL #6 SOL GC-002 BVC-2 VGC2 #2 STR. # SOL GC-002S BVC-2S VGC200 /0 STR. #4 SOL GC-020 BVC-20 VGC020 2/0 STR. # SOL GC-020S BVC-20S VGC4040 4/0 STR. # SOL GC-040 BVC-40 *Wire range indicates each connector s ability to accommodate two wires of the same size shown in the MX or MIN columns Thomas & Betts Corporation. Specifications are subject to change without notice.

11 Parallel Groove Connectors Type P One and Two-Bolt luminum Parallel Groove Clamps or use on copper, aluminum and CSR conductors. Order pre-filled with oxide inhibitor for use on copper to aluminum. Clamps are high-strength, heat treated cast aluminum alloy. Galvanized steel carriage bolt, nut and lockwasher are standard; for hex head bolts add suffix. P is extruded aluminum alloy, furnished with hex head bolt. Conductor Diameter Cat. No. Main Tap Main Tap Bolt Standard Prefilled CSR L/CU CSR L/CU max. min. max. min. H L W Size P str. 6 sol str. 6 sol P /0 6 /0 str. 6 sol. /0 6 /0 str. 6 sol P4 P4 /0 6 /0 str. 6 sol. /0 6 /0 str. 6 sol P P /0 8 /0 str. 8 sol. /0 8 /0 str. 8 sol P6 P6 /0 8 2/0 str. 8 sol. /0 8 2/0 str. 8 sol P0 P0 6.4 /0 400 /0 str. /0 6 R /0 6 R /0 8 /0 str. 8 sol P2 P2 4/0 2 4/0 str. 2 sol. 4/0 2 4/0 str. 2 sol P400* P400* 6.4 /0 400 /0 str. /0 6 R /0 6 R 6.4 /0 400 /0 str Blackburn * P 400 and 400 are two bolt clamps. R = Over armor rod RUS Listed. Cast P P Type PC luminum Parallel Groove Clamps with Cast Copper Liner luminum body cast around pronged copper liner effectively seals out moisture. Corrosion resistant; copper conductor is in contact with copper aluminum conductor surrounded by aluminum; clamp provides wide physical separation of conductors reducing possibility of galvanic corrosion; aluminum bodies are pressure cast of corrosion resistant alloy; steel bolt and lockwasher are galvanized, and the nut is nickel plated. One piece construction; no loose parts to assemble during installation; copper inserts always face each other; carriage bolts urnished standard. or hex head bolt add suffix. Cat. No. Main Tap Conductor Diameter Standard Prefilled CSR L Copper Main Tap H W L PC4 # PC4 /0 8 /0 str. 8 sol. /0 str. 8 sol / /0 str. PC PC /0 str. 8 sol /0 6 R /0 6 R RUS Listed Thomas & Betts Corporation. Specifications are subject to change without notice. 4

12 Parallel Groove Connectors Type PE Parallel Groove Clamps, Extruded Type Extruded parallel groove clamps for use on aluminum to aluminum or aluminum to cop-per connections with oxide inhibitor. Tin plating (-P) or wax dip (-6) must be specified for without oxide inhibitor filled connectors. Standard PE clamp is supplied with contax (-) and galvanized steel hardware. lll connectors can be installed with live line tools. Options: - luminum hardware -P Tin plating -6 Wax dip for oxide protection Example: Cat. Number for PE 22 with Contax and aluminum hardware is PE-22-. Blackburn Conductor Diameter (in.) Galvanized luminum Main Tap Steel Bolt Bolt Cat. No. Main Tap max. min. max. min. ig. H W L B Thd. Size. Thd. Size PE-22-2/0 CSR 6 sol. 6 R 2/0 CSR 6 sol. 6 R UNC 6 UNC PE-44-4/0 CSR 2 sol. 4-6 R 4/0 CSR 2 sol. 4-6 R UNC 6 UNC PE CSR /0 str. 2/0 str. 6 sol. 2/0 6 R 6 R UNC UNC PE kcmil-. 4/0 CSR 2 sol. CSR 6.4 2/0 R 4-6 R UNC UNC PE---2. CSR /0 str. /0 CSR 2 str. 2/0 6 R 6 R UNC UNC PE---2. CSR /0 str.. CSR /0 str. 2/0 6 R 2/0 6 R UNC UNC PE kcmil. 2/0 str. 6 sol. CSR 6.4 2/0 R 6 R UNC UNC PE kcmil.. CSR /0 str. CSR 6.4 2/0 R 2/0 6 R UNC UNC PE kcmil. 000 kcmil. CSR 6.4 2/ R CSR 6.4 2/0 R UNC UNC RUS Listed. ig. ig. 2 ig. ig. 4 ig. ig Thomas & Betts Corporation. Specifications are subject to change without notice.

13 Parallel Groove Connectors Type PC Two-Bolt Parallel Groove Clamp copper alloy parallel groove clamp; hex head bolts with square shank of silicon bronze, spring washers also of silicon bronze. Square shank bolts prevent turning while tightening. Contour of casting permits use of socket wrench if desired. Large contact area increases conductance. No special tools required. Not recommended for aluminum conductor Conductor Diameter WG or kcmil (in.) Main Tap B Cat. No. max. min. max. min. max. min. max. min. PC20 20 str. 4 sol. 20 str. 4 sol f z 2j e c Blackburn Cast of high strength copper alloy. urnished with silicon bronze hex washer head bolt. Parallel groove design; no need to remove bolt for installation. Only one size for all requirements from No. 8 solid copper to /0 CSR or 2/0 copper. vailable plated, unplated or with plating in one groove. Type K Jumper Clamps Plated Groove Copper Groove Cat. No. Max. Min. Max. Min. K /0 SCR 2 SCG amerductor 6 galv. strand 2/0 str. 6 CSR copper 2SCG 6 amerductor Copperweld* 8 solid iron 2 Copperweld* 8 solid copper -2D Copperweld* etc. Plated with plating removed from one groove. or use with aluminum, amerductor, or galvanized steel strand to copper or copper bonded steel wires. Either Groove Cat. No. Max. Min. /0 CSR 6 CSR K2 2 SCG amerductor 2 SCG 6 galvanized amerductor steel strand 8 solid iron Clamp plated. or use with amerductor, aluminum, or galvanized steel stranding. Either Groove Cat. No. Max. Min. K 2/0 str. copper 6 copperweld* 2 copperweld* Clamp, not plated. or copper to copper connections. * Trademark of Copperweld. 8 solid copper D copperweld* etc Thomas & Betts Corporation. Specifications are subject to change without notice.

14 Insulated Conductor Connectors Blackburn Performs as a splice or tap for non-tension applications up to 600 Volts depending on the size of the connector. Eliminates need for conductor insulation stripping. Self-insulated for hot line applications. No taping required after installation. or copper to copper, copper to aluminum and aluminum to aluminum applications. U.L. 486B Listed LCU (0 C rated). or use on insulated conductor only. Six connector line covers the range from #0-00 kcmil. Type IPC Talon Insulation Piercing Connectors L or CU WG/mm 2 No. Cat. No. Main Tap Bolts ig W H L IPC02* / IPC4 4/0 /0 / IPC44 4/0 /0 4/0 / IPC04* / IPC 0 4/0 0 4/ IPC4 0 4/0 4/ * 600 Volt Rating (ll others 00 Volt). ig. ig. 2 Type PT Insulated Phase Line Connectors Number of Main Tap Cat. No. Taps WG CSR WG CSR PT4 4 4/0 str. 2 str. 2/0 2 /0 str. 6 sol. 2-6 Takes up to 4 taps; taps may be added later without interrupting service or removing cover. Stainless steel hardware may be tightened with 6" wrench or with hexagonal llen wrench, provided with each standard package. Impact resistant cover and clamp clearly marked with easy to read cable ranges. Extended insulating shields make cable stripping easier. Prefilled with Blackburn Contax Thomas & Betts Corporation. Specifications are subject to change without notice.

15 Two-Bolt Connectors Castings and bolts of high-strength copper alloy. Cap is removable; neoprene washers capture each bolt in bottom casting, aiding installation. U.L. 486 Listed for copper conductor only. Type 2B Two-Bolt Connector without Spacer (WG or kcmil) Conductor Main Tap Diameter (B) Bolt Cat. No. max. min. max. min. max. min. Head L H D 2B0 /0 str. 2 str. /0 str. 0 sol B20BB 2/0 str. 2 str. 2/0 str. 8 sol B40 4/0 str. /0 str. 4/0 str. 6 sol B0 0 kcmil 4/0 str. 0 kcmil 4 sol B00 00 kcmil 0 kcmil 00 kcmil 4 sol B kcmil 600 kcmil 800 kcmil 2 sol B kcmil 0 kcmil 000 kcmil 2 sol U.L. 486 Blackburn Type 2BX One-Piece Two-Bolt Connector without Spacer (WG or kcmil) Conductor Main Tap Diameter (B) Bolt Cat. No. max. min. max. min. max. min. Head L H D Castings and bolts of high-strength copper alloy. One piece construction. ree bolt is held in place with neoprene washer during installation. One extra length bolt allows top casting to swing free over two conductors of maximum range. U.L. 486 Listed for copper conductor only. 2B0X /0 str. 2 str. /0 str. 0 sol B20X 2/0 str. 2 str. 2/0 str. 8 sol B40X 4/0 str. /0 str. 4/0 str. 6 sol B0X 0 kcmil 4/0 str. 0 kcmil 4 sol B00X 00 kcmil 0 kcmil 00 kcmil 4 sol B800X 800 kcmil 600 kcmil 800 kcmil 2 sol B000X 000 kcmil 0 kcmil 000 kcmil 2 sol U.L Thomas & Betts Corporation. Specifications are subject to change without notice.

16 Two-Bolt Connectors Blackburn U.L. 486 Listed for copper conductor only. or use on copper conductors only. Castings and bolts of high-strength copper alloy; spacer of ductile, high-conductivity copper alloy. One-piece construction; contoured spacer is ringed and swings easily over the conductor. Type 2BW One-Piece Two-Bolt Connector with Spacer (WG or kcmil) Conductor Diameter Main Tap B Bolt Dimensions Cat. No. max. min. max. min. max. min. max. min. Head L H E 2B0W /0 str. 2 str. /0 str. 0 sol B20W 2/0 str. 2 str. 2/0 str. 8 sol B40W 4/0 str. /0 str. 4/0 str. 6 sol B0W 0 kcmil 4/0 str. 0 kcmil 4 sol B00W 00 kcmil 0 kcmil 00 kcmil 4 sol B800W 800 kcmil 600 kcmil 800 kcmil 2 sol B000W 000 kcmil 0 kcmil 000 kcmil 2 sol Type 2BPW One-Piece Two-Bolt Connector with Spacer (WG or kcmil) Conductor Dia. Main Tap B Bolt Dimensions Cat. No. max. min. max. min. max. min. max. min. Head L H E 2B0PW /0-2 /0-6 /0 str.-2 str. /0 str.-2sol /2 /6 /8 2B20PW 2/0-2 2/0-6 2/0 str.-2 str. /0 str.-2sol /2 /6 /8 2B40PW 4/0-/0 4/0-6 4/0 str.-/0 str. 4/0 str.-/0sol /6 2 /2 2 /8 2B0PW 0-4/ /0 0-4 sol /4 2 /8 2 /2 2B00PW sol /4 2 /4 2 /4 2B800PW sol /4 2 /2 /4 2B000PW sol /6 2 /2 /4 / /6 /6 /8 /2 /2 /2 /8 U.L. 486 Listed for copper conductor only. or use on copper, aluminum and CSR conductors Thomas & Betts Corporation. Specifications are subject to change without notice.

17 Cross Tap Clamps/Dead End Clamps Type XT Clamp for Tee Tap, Cross, Parallel and End-to-End Connectors (WG or kcmil) Conductor Diameter Main Tap B Dim. (in.) Bolt Cat. No. max. min. max. min. max. min. max. min. L H W Size XT2 4/0 str. str. 2 str. 6 sol XT 4/0 str. str. 4/0 str. str XT2 00 kcmil 20 kcmil 2 str. 6 sol XT22 00 kcmil 20 kcmil 4/0 str. str XT2* 00 kcmil 20 kcmil 00 kcmil 20 kcmil XT* 000 kcmil 00 kcmil 00 kcmil 20 kcmil XT4* 000 kcmil 00 kcmil 000 kcmil 00 kcmil multi-purpose connector; castings of copper alloy; bolts of silicon bronze. Design allows for free wrench rotation which speeds installation. or tin-plated style add suffix P to Cat. Number e.g. XT2P. * 4 bolt clamps 6 Blackburn Type DLC Single U Bolt luminum ittings Top and bottom pressure pads cast of high strength, heat treated, aluminum silicon alloy. Extra long separating spacer of highly conductive aluminum; spacer interlocks with U bolt will not drop out. Spring action counteracts cold flow. No special tools required for installation. Suitable for deadend loop connections. Hardware of high-strength galvanized steel. or use on copper, aluminum and CSR conductors. Order pre-filled with oxide inhibitor (suffix ) for use on aluminum to copper. Conductor Diameter CSR WG or kcmil B Cat. No. Main Tap Main Tap max. min. max. min. W L H E DLC206 2/0 6 2/0 6 2/0 str. 6 sol. 2/0 str. 6 sol DLC2 4/0 2 6 R 4/0 / /0 str /0 str DLC2 6.4 /0 6.4 /0 /0 6 R /0 6 R. /0 str.. /0 str RUS listed 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

18 Hot Line Clamps Blackburn Eye-bolt coated with high temperature grease, assuring easy turning in all weather conditions. vailable prefilled with oxide-inhibiting Contax and individually packaged; add suffix to Cat. Number. HLC208 Series is for 2/0 8 main line conductor. HLC4 Series is for. kcmil 6 main line conductor. Type HLC Hot Line Clamps (Protected Thread) or Wire Main Tap Cat. No. Combination CSR WG or kcmil CSR WG Bronze Body Copper to HLC208 Copper 2/0 8 2/0 Plated Bronze General Body Purpose HLC208P 2/0 6 2/0 8 2/0 6 2/0 8 Plated luminum General Body Purpose HLC208P 2/0 6 2/0 8 2/0 6 2/0 8 Bronze Body Copper to HLC4 Copper sol. 4/0 6 sol. Plated Bronze General Body Purpose HLC4P sol. /0 6 4/0 6 sol. Plated luminum General Body Purpose HLC4P sol. /0 6 4/0 6 sol. RUS Listed. Type PGH Center Bolt Parallel Groove Hot Tap Clamps Incorporates the superior design features of parallel groove clamps, time-proven for their reliable performance. Protected threads; wide temperature range lubricant prevents seizing. Tap wire positively secured to clamp during installation and removal by hex head bolt and pressure pad; main and tap clamped securely as clamp is tightened. vailable prefilled with Contax, add suffix. Copper clamps are for use on copper conductors only. ig. ig. 2 ig. Conductor Diameter Center Dimensions Cat. No. Main Tap Main Tap Bolts (in.) Std. Pre-filled CSR WG CSR WG max. min. max. min. No. Dia. ig. W H L luminum Clamps PGH2 2/0 8 2/0 str. 8 sol. /0 8 /0 str. 8 sol PGH4 PGH4. 6 2/0 6 R 40 4 sol. /0 6 4/0 str. 6 sol PGH6 84 4/ R 000 4/0 str sol PGH62* 84 4/ R 000 4/0 str sol Copper Clamps PGH PGH 2/0 str. 8 sol. 2/0 str. 8 sol * PGH62 has two hex head bolt and pressure pad tap conductor retainers. R-with rmor Rod Thomas & Betts Corporation. Specifications are subject to change without notice.

19 Multi-Bolt Connectors Types 4B, 6B One Piece Multi-Bolt Connectors Cap and pressure plate of cast aluminum alloy; spacer of high conductivity aluminum. High strength aluminum alloy bolts and lock washers prevent seizing. One piece construction eliminates loose parts during installation. or use on copper, aluminum and CSR conductors. actory filled with Contax oxide inhibitor. Conductor Diameter No. CSR WG or kcmil B of Cat. No. Main Tap Main Tap max. min. max. min. W H T L E Bolts 4B2 4/0 4 4/ str sol B4. /0. /0 4 /0 str. 4 /0 str B Blackburn 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

20 MT Connectors NEW MT Connectors The high quality and built-in flexibility of the new Blackburn MT Connectors reduce the cost of field installations on splices, taps, and terminations. They re easy and quick to install, and provide superior insulation that lasts the life of the connection. eatures and Benefits: PVC insulation eliminates insulation failures and reduces outage costs. UV resistant material. Compact design provides space efficiencies. UL Listed. Blackburn Cat. No. Description ig. UPC Std. Ctn. MTD0066 Insulated Six Hole Both Sides or 00-#6 WG MTD006 Insulated ive Hole Both Sides or 00-#6 WG MTD0064 Insulated our Hole Both Sides or 00-#6 WG MTD006 Insulated Three Hole Both Sides or 00-#6 WG MT00 Insulated Two Hole Same Side or 00-#6 WG MTD006 Insulated Six Hole Both Sides or 0-#0 WG MTD00 Insulated ive Hole Both Sides or 0-#0 WG MTD004 Insulated our Hole Both Sides or 0-#0 WG MTD00 Insulated Three Hole Both Sides or 0-#0 WG MTS006 Insulated Six Hole Same Side or 0-#0 WG MTS00 Insulated ive Hole Same Side or 0-#0 WG MTS004 Insulated our Hole Same Side or 0-#0 WG MTS00 Insulated Three Hole Same Side or 0-#0 WG MT0 Insulated Two Hole Same Side or 0-#0 WG MTS2008 Insulated Eight Hole Same Side or 20-#0 WG MTD2006 Insulated Six Hole Both Sides or 20-#0 WG MTD200 Insulated ive Hole Both Sides or 20-#0 WG MTD2004 Insulated our Hole Both Sides or 20-#0 WG MTD200 Insulated Three Hole Both Sides or 20-#0 WG MTT20 Insulated Two Hole Opposite Sides for 20-#0 WG MT20 Insulated Two Hole Same Side for 20-#0 WG MTS44 Insulated our Hole Same Side for #4-#4 WG MTTC4 Insulated Two Hole Opposite Sides for #4-#4 WG MTC4 Insulated Two Hole Same Side for #4-#4 WG MTT20 Insulated Two Hole Opposite Sides for 2/0-#4 WG MT20 Insulated Two Hole Same Side for 2/0-#4 WG MTSR00 Insulated luminum Splice 00-#0 WG MTSR0 Insulated luminum Splice 0-#6 WG MTSR20 Insulated luminum Splice 20-#6 WG MTSR0 Insulated luminum Splice /0-#4 WG ig. ig. 2 ig. ig. 4 ig Thomas & Betts Corporation. Specifications are subject to change without notice.

21 Copper Mechanical Connectors Type L Single Conductor, One Hole Mount Cat. No. Socket Hex max. min. L W H D J E G L* 8 str. 4 sol. 6 L0* 4 str. 4 sol. 2 L2 L2H /0 str. 8 sol L20 L20H 20 kcmil 6 str L400BB L400H 00 kcmil 4/0 str. L60 L60H 000 kcmil 00 kcmil Copper Mechanical Connectors or copper conductors. Screws are plated steel. Compact design. dd suffix P to cat. number for tin plating. One-piece construction for strength and durability. Excellent for confined quarters. Cat. Nos. L400 and L60 are cast from high strength bronze alloy. Cat. Nos. L, L0, L2 and L20 are cold forged from pure electrolytic copper with % conductivity. * Sizes L and L0 have screwdriver slot head screws only. U.L. 486 Blackburn Type L Single Conductor, Two Hole Mount Cat. No. Socket Hex max. min. L W H D K E G J L22 L22H /0 str. 4 str L202 L202H 20 kcmil /0 str. 6 L4002 L4002H 00 kcmil 4/0 str. 6 L602 L602H 000 kcmil 00 kcmil U.L. 486 Cast from high strength bronze alloy. or use where large contact area is required to provide a more secure mounting Thomas & Betts Corporation. Specifications are subject to change without notice.

22 Copper Mechanical Connectors Type TL Two Conductor, Two Hole Mount Cat. No. Socket Hex max. min. L W H D K E G J TL20 TL20H 20 kcmil /0 str TL400 TL400H 00 kcmil 4/0 str TL60 TL60H 000 kcmil 00 kcmil our hole NEM tang on TL60. U.L. 486 Conveniently terminates parallel conductors. Blackburn Type S Copper End-to-End Splice Connector Cat. No. max. min. L W H J I S00BB str. 4 sol. 6 6 S22BB* 4/0 str. str S400BB 00 kcmil 4/0 str * Not U.L. Listed. Cast of high strength copper alloy. Plated steel socket head set screws Thomas & Betts Corporation. Specifications are subject to change without notice.

23 Copper Mechanical Connectors Type STC Copper Single Conductor, One Hole Mount (Straight Tang) ig. Cat. No. No. max. min. L W H E D STC04* 0 WG 4 WG 6 6 STC str. 4 WG 6 STC str. 4 WG 2 STC str. 8 str. STC02 /0 str. 2 str. 6 6 STC04 /0 str. 4 str Uniquely designed pressure bar and notched v-bottom collar provide a vise-like grip between conductor and terminal. U.L. 486 tested for copper conductor. Made of electrolytic seamless copper. Screws are zinc plated steel. STC402 4/0 str. 2 str. 2 2 STC 0 kcmil /0 str. STC0 00 kcmil /0 str. 6 STC kcmil 600 kcmil 2 2 * Not CS Listed. D W Blackburn E ig. ig. 2 ig. Type BTC Copper Single Conductor, One Hole Mount (Offset Tang) ig. Cat. No. No. max. min. L W H E D BTC04* 0 WG 4 WG 6 4 BTC str. 4 WG 2 BTC str. 8 str. 2 BTC02 /0 str. 2 str. 2 BTC04 /0 str. 4 str. 2 6 BTC402 4/0 str. 2 str BTC 0 kcmil /0 str. 2 BTC0 00 kcmil /0 str BTC kcmil 600 kcmil *Not CS Listed E DI. ig. ig. 2 ig Thomas & Betts Corporation. Specifications are subject to change without notice. 6

24 nti-rotational Connector NEW nti-rotational Connector Thomas & Betts new nti-rotational Connectors are designed with a rib on the bottom that keeps the connectors from turning, so there s no need to apply excessive torque and there s no danger of loosening connectors. The unique no turn rib provides a secure connection that eliminates conductor pinching that results from connector movement. The new no turn design feature solves a unique problem for electricians and installers. Larger conductors tend to get damaged in overtorque conditions, and connectors are prone to loosen in applications where there is vibration such as motor loads. Inspectors and local standards boards are requiring electricians and installers to make provisions to eliminate these conditions, and Blackburn nti-rotational Connectors are the solution. Blackburn Std./Outer Cat. No. Description Net Each Wt./00 UPC ig. DR2-R 2/0-4WG, b Bolt Hole 2/ ig. DR0-R 00MCM-6WG, k Bolt Hole 2/ ig. DR-R 0MCM-6WG, j Bolt Hole 2/ ig. DR60-R 600MCM-2WG, d Bolt Hole 6/ ig. DR-2-R 0MCM-6WG, c Bolt Hole 6/ ig.2 DR60-2-R 600MCM-2WG, d Bolt Hole 4/ ig.2 ig. ig Thomas & Betts Corporation. Specifications are subject to change without notice.

25 Dual-Rated Mechanical Connectors Type DR LCÜL Single Conductor, One-Hole Mount (L or CU) Cat. No. max. min. L W H D E G Slotted Screw DR6 6 str. 4 WG 4 DR2 2 str. 4 WG 6 6 DR /0 str. 4 WG or copper and aluminum conductors. Easy installation no special tools required. Tin plated for low contact resistance. U.L. 486B tested, LCU Rated. ll aluminum bodies. Slotted screw on lugs up through 2/0 str.; 6 socket screw on sizes 20 through 0 kcmil; c hex socket on sizes 00 kcmil and above. DR2 2/0 str. 4 WG Socket Screw DR2 20 kcmil 6 str. 2 DR0 00 kcmil 6 str. 2 DR 0 kcmil 6 str. 2 DR0 00 kcmil 4 str DR kcmil 2 str kcmil 4 str. DR6004* (2) 20 kcmil (2) /0 str DR kcmil 00 kcmil 6 DR 000 kcmil 00 kcmil Blackburn * Not U.L. or CS Listed. øe Bolt Hole W BKB CUL D L G H Type DR LCÜL Single Conductor, Two-Hole Mount* (L or CU) Cat. No. max. min. L W H D E G DR-2 # 0 kcmil 6 str. 4 6 DR60-2D 600 kcmil 2 str. 6 DR80-2D 800 kcmil 00 kcmil 6 6 DR-2D 000 kcmil 00 kcmil * NEM spacing: " centers # U.L. Listed. Connectors accommodating conductors 600 kcmil and larger have double row of set screws ( D suffix). E Bolt Size 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 6

26 Dual-Rated Mechanical Connectors Blackburn Type DR LCÜL Single Conductor, Switchgear Mount* (L or CU) Cat. No. max. min. L W H D E G DR2-2S 20 kcmil /0 str. 6 2 DR-2S 0 kcmil 4 str DR0-2S 00 kcmil 400 kcmil DR80-2DS 800 kcmil 00 kcmil DR-2DS 000 kcmil 0 kcmil * NEM Spacing: f" centers except DR2-2S: " centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws ( D suffix). E Bolt Size Type DR LCÜL Two Conductor, One-Hole Mount (L or CU) Cat. No. max. min. L W H D E G I DR-2 /0 str. 4 WG DR2-2* 2/0 str. 4 WG DR kcmil 6 str DR-2 0 kcmil 6 str. 2 6 DR kcmil 2 str DR kcmil 00 kcmil 6 6 DR kcmil 00 kcmil 6 6 * Not CS Listed. U.L. 486B LCU E Bolt Size Thomas & Betts Corporation. Specifications are subject to change without notice.

27 Dual-Rated Mechanical Connectors Type DR LCÜL Two Conductor, Two-Hole Mount* (L or CU) Cat. No. max. min. L W H D E G I DR-22** 0 kcmil 6 str DR60-22D 600 kcmil 2 str DR80-22D 800 kcmil 00 kcmil DR-22D 000 kcmil 00 kcmil * NEM Spacing: " centers. ** U.L. Listed. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). U.L. 486B, LCU W L I G H Blackburn D f E Bolt Size Type DR LCÜL Three Conductor,Two-Hole Mount** (L or CU) Cat. No. max. min. L W H D E G I DR str. 4 WG DR-2 /0 str. 4 WG DR-2* /0 str.. 6 str DR2-2* 20 kcmil 6 str DR-2* 0 kcmil 6 str DR0-2* 00 kcmil 4 str DR60-2D 600 kcmil 2 str DR80-2* 800 kcmil 00 kcmil DR-2* 000 kcmil 00 kcmil * U.L. Listed. ** NEM Spacing: " centers except DR02-2; centers and DR-2; centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). U.L. 486B, LCU E Bolt Size f 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 6

28 Dual-Rated Mechanical Connectors Type DR LCÜL Three Conductor, our-hole Mount** (L or CU) Cat. No. max. min. L W H D E G I Blackburn DR str. 4 WG 2 6 DR-4 /0 str. 4 WG DR-4 /0 str. 6 str DR2-4* 20 kcmil 6 str DR-4* 0 kcmil 6 str DR0-4* 00 kcmil 4 str DR60-4D 600 kcmil 2 str DR80-4* 800 kcmil 00 kcmil DR-4* 000 kcmil 00 kcmil * U.L. Listed. ** NEM Spacing: " centers except DR02-4; " centers and DR-4; " centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). U.L. 486B LCU f E Bolt Size Type DR LCÜL Three Conductor, our-hole Mount* (L or CU) Cat. No. max. min. L W H D E G I DR kcmil 6 str DR-44 0 kcmil 6 str DR60-44D 600 kcmil 2 str DR80-44D 800 kcmil 0 kcmil * NEM Spacing: " centers. Connectors accommodating conductors 600 kcmil and larger have double row of set screws (D suffix). E f Bolt Size Thomas & Betts Corporation. Specifications are subject to change without notice.

29 Dual-Rated Mechanical Connectors Type SL LCÜL Two Conductor, One-Hole Mount (L or CU) Cat. No. max. min. L W H D Mtg. Hole Dia. SL kcmil 6 str. 2 6 u DI. i c Blackburn Type SL LCÜL Two Conductor, Two-Hole Mount (L or CU) Cat. No. max. min. L W H D SL kcmil 2 str. 4 2 SL kcmil /0 str. 4 2 U.L. 486B LCU i c c u DI. 2 HOLES 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. 6

30 Dual-Rated Mechanical Connectors Type SL LCÜL Three Conductor, Two-Hole Mount (L or CU) Cat. No. max. min. L W H D I SL kcmil 2 str SL-2 0 kcmil /0 str Blackburn i u DI. 2 HOLES c Type SL LCÜL our Conductor, Two-Hole Mount (L or CU) Cat. No. max. min. L W H D I SL kcmil 2 str SL-42 0 kcmil /0 str i c u DI. 2 HOLES Thomas & Betts Corporation. Specifications are subject to change without notice.

31 Dual-Rated Mechanical Connectors Type SR LCÜL Splicer Reducer with Solid Barrier Wire Stop (L or CU) Cat. No. max. min. L W H I SR024* 2 str. 4 WG 2 SR4* /0 str. 4 WG 2 SR kcmil 6 str. 2 SR06 0 kcmil 6 str. 2 SR2** 0 kcmil 20 kcmil 6 * Slotted screws ** Two set screws per end. Not CS Certified. U.L. 486B LCU W L I H Blackburn Type BX LCÜL Rectangular Connectors Conductor Style & Boss Range Size of Hole Cat. No. max. min. Boss Tapped L W H BX CU Square 2L.22 in BX4 /0 4CU Square 2L.22 in. 0-2 Recognized component in accordance with U.L. 486B standard 0 C rating. nti-rotational boss Thomas & Betts Corporation. Specifications are subject to change without notice. 6

32 Dual-Rated Mechanical Connectors Type GP luminum Dual Rated Mechanical Connectors Parallel Tap Connectors (L or CU) Cat. No. Main Tap W L H Blackburn GP-2* 2 2 str. 4 4 GP-0 /0 2 /0 4 GP /0 / GP / GP-0 0 4/ GP GP GP /0 2 * Slotted screw, tap side. To include insulating cover add suffix WC. No cover available for GP-0-. Type GT luminum Dual Rated Mechanical Connectors Parallel Tap Connectors (L or CU) Cat. No. Main Tap W L H GT-2* 2 2 str. 4 4 GT-0 /0 2 /0 4 GT /0 / GT / GT-0 0 4/ GT GT * Slotted screw, tap side. To include insulating cover add suffix WC Thomas & Betts Corporation. Specifications are subject to change without notice.

33 Dual-Rated Mechanical Connectors Type TC Insulating Covers for GP-GT Use with Cat. No. Colour L W H Connector TC-2 Yellow 2 6 GP-2, GT-2 TC-0 Grey GP-0, GT-0 TC-20 Red 2 GP-20, GT-20, GP-20-0, GT-20-0 TC-0BB Yellow 2 2 GP-0, GT-0 TC-00 Blue GP-00, GT-00 TC-0 Orange 4 2 GP-0, GT-0 Blackburn Tightening Torque Values for luminum Dual Rated Socket Screw Connectors WG or WG or Circular Tightening Torque in in-lb Circular Tightening Torque in in-lb Mil Size Screw Driver Wrench Mil Size Screw Driver Wrench / / / / Thomas & Betts Corporation. Specifications are subject to change without notice.

34 Miscellaneous Hardware Blackburn or tin-plated silicon bronze hardware, add suffix P to Cat. Number. Bolts 2" long or less have full thread; longer bolts have 2" of thread, except b" 20 bolts have b" min. thread. Type BB Silicon Bronze Hardware Hex Head Bolts Cat. No. Length Diameter and Threads per inch (in.) b" 20 j" 8 c" 6 d" 200BB 00BB 00BB 000BB 2BB 2BB 02BB 0BB 0BB 00BB BB BB 0BB 2 200BB 200BB 0200BB 2 222BB 22BB 22BB 022BB 2 20BB 20BB 020BB 2 2BB 2BB 02BB 00BB 00BB 000BB 2BB 02BB 0BB 00BB Type HN Bronze Hex Nuts Diameter Cat. No. and Threads per inch 400HN 20 00HN HN 6 000HN Type SW Bronze Split Lockwashers Cat. No. Bolt Size (in.) 400SW 00SW 6 00SW 000SW Type W Bronze lat Washers Bolt Sizes O.D. I.D. Thickness Cat. No. (in.) (in.) (in.) (in.) 4040W W W W.62.0 Type BW Belleville Washers 02 Series Stainless Steel Bolt Size O.D. I.D. Thickness Height Cat. No. (in.) (in.) (in.) (in.) (in.) 000BW Thomas & Betts Corporation. Specifications are subject to change without notice.

35 LOCKTITE Connectors Code Copper Conductor (for 600V) Each standard one-hole lug fits many sizes of copper cable, thus only nine lug sizes are required to accommodate all cables from #4 to 000 kcmil. Easily installed with a key wrench. Saddle and cable socket make direct, all around, low resistance contact with cable. Convenient peep hole permits easy inspection. One-Bolt Hole Cable Cat. No. Size G B C D J 00 4 to 8 d a l d a w s 00 8 to 4 d a e d a w s 00 4 to d e m e r X 00 to 2/0 c n m b i k 0 2/0 to 4/0 c 2c b s u w 0 4/0 to 00 d 2f d i j w e 0 00 to 00 d h L c X m f 0 00 to 0 d 2i e u 2a 0 0 to 000 e 4j 2v g v 2X i With ilister Head Screw. ll others, hex socket screws. G Bolt Size C Blackburn J B D One-Bolt Hole lag Type Cable Cat. No. Size G B C D J E 00-L 8 to 4 b a e d a w s d With ilister Head Screw Bolt holes and spacings listed are standard, but lugs with blank tongues can be furnished. or torque requirements see page C. G Bolt Size E C J B D 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

36 LOCKTITE Connectors Code Copper Conductor (for 600V) Blackburn The outstanding LOCKTITE lug features of easy installation, high conductivity and wide cable range are available in this lug with a long tongue adapted for two bolts. G Bolt Size H C One-Bolt Hole 0 Upright Cable Cat. No. Size G B C D J 00-UL 8 to 4 b a e d a d s 00-UL 4 to b y m e r m X 00-UL to 2/0 c 2o m b n k 0-UL 2/0 to 4/0 c 2d b s a w With ilister Head Screw. ll others, hex head screws. Bolt holes and spacings listed are standard, but lugs with blank tongues can be furnished. Two-Bolt Hole Cable Cat. No. Size G B C D J H to 8 b L b d a v s e to 4 b f b d a w s e to b 2b k e r g s f 200 to 2/0 c 2g n m b u k 20 2/0 to 4/0 c a 2 s n k 20 4/0 to 00 c c 2a i j l k to 00 c d 2a c X B k to 0 d 4x f u 2a l d 20 0 to 000 d 4B g v 2X l d With ilister Head Screw. ll others, hex head screws. or torque requirements see page C. J B D These two-hole lugs are furnished with bolt holes and spacings to fit equipment supplied with NEM type connector mounting pads. G Bolt Size H C Two-Bolt Hole NEM Drilled Cable Cat. No. Size G B C D J H to c 2m 2 f r g k 220 to 2/0 d n b L l f 22 2/0 to 4/0 d 4a s s l f 22 4/0 to 00 d 4i i j v l f to 00 d 4g d c X m l f to 0 d p d f u 2a l f 22 0 to 000 d b d v 2a l f or torque requirements see page C. J B D Thomas & Betts Corporation. Specifications are subject to change without notice.

37 LOCKTITE Connectors Code Copper Conductor (for 600V) Double and triple barrel LOCKTITE lugs have same features as single barrel: screw tightening, serrated saddle, built-in lock washer. Double Barrel/Triple Barrel NEM Drilled 600V pplications Cable Cat. No. Size ig. G B C D E H J 200BD 4 to 8 b 2i f e a L s e v 200BD 8 to 4 b 2d 2 a s e w 200BD 4 to c 2m 2 b r b k C 200BD to 2/0 d 4k d d b l e f u 20BD 2/0 to 4/0 d 4e d f s f e f n 20BD 4/0 to 00 d 4f d 2 j 2a e f l 20BD 00 to 00 d c n 2d X 2d e f m 20BD 00 to 00 B d x 4 4 u 2n e f 2a 20BD 0 to 000 B d B 4 4 v b e f 2X 20TB 2/0 to 4/0 C d 4e c 2d s 2f e f n 20TB 4/0 to 00 C d 4f d j b e f w 20TB 00 to 00 D d c 4 4 X f e f m 20TB 00 to 0 D d x 4 4 u 4c e f 2a 20TB 0 to 000 D d B 4 4 v 4m e f 2X With ilister Head Screw or torque requirements see page C. Bolt Size Bolt Size Blackburn E C E H C B H B H J D J D ig. ig. B Bolt Size Bolt Size E C E H C B H B H J D J D ig. C ig. D 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

38 LOCKTITE Connectors Code Copper Conductor (for 600V) Blackburn Two-way connectors join two cables end to end. Cables are held by saddle, tightened by screws. Lock washers are built in. Two-Way Connectors Cable Cat. No. Size E J 20 4 sol. to 8 sol. a c v 20 8 sol. to 4 str. c d w 20 4 sol. to str. e e B 20 sol. to 2/0 g f o 2 2/0 to 4/0 2j n b 2 4/0 to 00 2l a d 2 00 to 00 2f b 2 00 to 0 a d 2h 2 0 to 000 g L 2s With ilister Head Screw or torque requirements see page C. E J These taps are designed for one-man installation. Tap hangs on main while the branch is being inserted and the screw tightened. Tee-Parallel Taps Cable Size Cat. No. Main Branch B C 0 00 to 00 2 to /0 2d f b 0 4/0 to 00 h g e 0 2 to /0 2m n b 0 00 to 0 4/0 to 00 c 2h e 0 00 to 0 4 2h 2h or torque requirements see page C. C B Thomas & Betts Corporation. Specifications are subject to change without notice.

39 LOCKTITE Connectors Code Copper Conductor (for 600V) or stranded, solid, flexible and other types of cables, each lug takes a range of wire sizes. Bolt holes and spacings listed are standard, but lugs with blank tongues will be furnished, if specified, without extra charge. Tandem Type Two-Bolt Hole NEM Drilled Cable Cat. No. Size G B C D J H 200TL 4 to c l 2 f r C k 200TL to 2/0 d 4n b p l f 20TL 2/0 to 4/0 d c s j l f 20TL 4/0 to 00 d e i j l l f 20TL 00 to 00 d 6X d c X e f 20TL 00 to 0 d 6z d f u 2a e f J G Bolt Size H B C D Blackburn Ground Bus Taps for " Copper Bus Bar or easy installation in hard-to-reach places, these bar taps eliminate the necessity of drilling holes in the ground bus. They can be placed quickly at any location, and the only installing tool is a key wrench. standard LOCKTITE lug grip securely holds the tapping cable. Wire Size Cat. No. (in.) B Bus Thickness 20 8 to 4 2b f b to 2l f b 20 to 2/0 2f f b 20 2/0 to 4/0 2f f b 2 4/0 to 00 2g f b to 00 f b or torque requirements see page C. B 2002 Thomas & Betts Corporation. Specifications are subject to change without notice.

40 LOCKTITE Connectors Code Copper Conductor (for 600V) * Hex head screws will be furnished if specified. To order, add prefix H to catalog number. On all except 4-0 and 0-8 code sizes. Pigtail Connectors Cable Cat. No. Size ig. J 0 0 to 8 d w 0 8 to 6 B f B 0 6 to 4 B g o 4 to 2 B h b to 2/0 B i d 2/0 to 4/0 B j or torque requirements see page C. Blackburn J ig. ig. B Stud Connectors Each connector will accommodate a wide range of conductor sizes. Installation is simple and the convenient pigtail is easy to tape. * Hex head screws will be furnished if specified. To order, add prefix H to catalog number. On all except 4-0 and 0-8 code sizes. Type MS Cable Stud Cat. No. Size G B D E Size (in.) 00-T 4 to c 6 c g e f c 6 00-T to 2/0 c 6 e g f f c 6 0-T 2/0 to 4/0 d e h i g d 0-T 4/0 to 00 d g i c h d 0-T 00 to 00 d 2q j d b d E B D Thomas & Betts Corporation. Specifications are subject to change without notice.

41 LOCKTITE Connectors Code Copper Conductor (for 600V) Standard tapping is shown in diagrams. Other tapping can be furnished for specific requirements. * Hex head screws will be furnished if specified. To order, add prefix H to catalog number. On all except 4-8 and 8-4 code sizes. Stud Connectors (continued) emale Type L Cable Stud Cat. No. Size ig. G B Size (in.) 26 4 to 8 c 6 p e c to 4 c 6 h e c to B c 6 v f c to B d v f d 26 2/0 to 4/0 B d 2i m d With ilister Head Screw G B G B Blackburn ig. ig. B T&B Recommended Tightening Torque Screw Size of Wrench Driver Conductor Torque Torque Ranges in.-lbs. in.-lbs. 4 to to 4 4 to 2 to 2/0 0 2/0 to 4/ /0 to to to to Thomas & Betts Corporation. Specifications are subject to change without notice.

42 LOCKTITE Connectors Code Copper Conductor (for 600V) LUG-IT connectors are designed to grip the cable firmly between the strong body and the serrated copper tongue. Double laps at the top give greater thread strength and lock the screw when it is tight. The copper tongue makes a low resistance terminal. LUG-IT Lugs One Hole, Offset Tongue Cable Cat. No. Size G B C D 0 4 to 6 #0 i d c.064 r 40 8 to 2 b k e d.08 b *0 4 to 2/0 b m m f.0 c *60 /0 to 4/0 c 2w p.28 d * luminum body Hex head bolt dd suffix G to above Cat. No s for lug connector with green screw for grounding identification. or torque requirements, see page C. Blackburn B C D Cone Screw Lugs Wire Torque Cat. No. Range G B C D E (in.-lbs.) The conically shaped screw compresses the copper conductor so that each strand is forced to carry its own share of the load. Equal pressure is exerted on each conductor strand and the cone screw assures high pull-out and low resistance #0 m k c p c i 20 * b q e l a x s * /0 c y B z i c /0 c g C n i O c c 2o C r c /0-00 d 2f b X s v l 00 dd suffix G to lug Cat. No. 00, 00, 00, and 04 for lug with green screw for grounding identification. U.L. ile No. E-60 *Indicates screwdriver torque; all others indicate torque wrench. G Bolt Size C B D E Thomas & Betts Corporation. Specifications are subject to change without notice.

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB Waterpipe Ground Clamps Cat. No. Ground Wire Size Water Pipe Size 2-TB 1/2 in., 3/4 in., 1 or rebar 4-10 3-TB 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, 4 2-1/2 in., 3 in. or 3-1/2 in. #2 WG 5-TB 4 in., 4-1/2

More information

GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER

GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER GENERAL USE VISE TYPE ALUMINUM SINGLE BOLT ALUMINUM TO ALUMINUM OR ALUMINUM TO COPPER ALUMINUM GA9000 Recommended for aluminum or aluminum to copper distribution, service or tap connections. Add Suffix

More information

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS

Small Terminals. TEST CURRENT (Amps) Fig 1. Tensile strength of YAD HYLUG after axial rotation stresses. TENSILE STRENGTH IN POUNDS B-2 Performance The terminals and splices in this catalog are approved, per MIL-T-7928 and/or UL 486, where indicated. Table 1 shows the performance requirements for terminals used in military and commercial

More information

General Terms and Conditions

General Terms and Conditions General Terms and Conditions MINIMUM ORDER CARGE PER ITEM $200.00 PRICES All prices are subject to change without notice and orders will be billed at prices in effect at the time of shipment. TRANSPORTATION

More information

Welding Accessories

Welding Accessories Welding Accessories www.airliquide.ca 1-800-817-7697 Welding Accessories BLUESHIELD Welding Cables Blueshield Welding Cables: Excellent flexibility (stays flexible at -50 C) Abrasion resistant Oil, solvent

More information

Grounding Systems. Table of Contents. EZGround

Grounding Systems. Table of Contents. EZGround EZGround Grounding Systems Table of Contents Thomas & etts offers a complete range of grounding products including mechanical, compression and exothermic systems. Whatever the application, there is a Thomas

More information

TABLE OF CONTENTS. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

TABLE OF CONTENTS. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products. H W U J B L T Substation Bolted TABLE OF CONTENTS COPPER SUBSTATION Introduction............... L-3 Type HFBW Bar Clamp............... L-13 Type NT Tube to Tube.............. L-4 Type HFB-P1 Bar Clamp...............

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

TABLE OF CONTENTS. Type HFB-P1... A-22. Type HFB-N... A-23. Types KA-U, KKA-U... A-24. Type K2A-U... A-25. Types K3A-U, KK3A-U...

TABLE OF CONTENTS. Type HFB-P1... A-22. Type HFB-N... A-23. Types KA-U, KKA-U... A-24. Type K2A-U... A-25. Types K3A-U, KK3A-U... BURNDY Mechanical A-1 TABLE OF CONTENTS Types KS, KS-3 & SC... A-4 Type KSU............ A-5 Type KSA............ A-6 Types KVS, KVSU...... A-7 Types KVSW, KVS-A... A-8 Type QPX............ A-9 Type QPX-Y.........

More information

Fig. 1 - Standard Clevis Hanger

Fig. 1 - Standard Clevis Hanger Revision 10/24/2007 Fig. 1 - Standard Clevis Hanger Component of State of California OSHPD Approved Seismic Restraints System Size Range Size 1/2" thru 36" pipe. Function Recommended for the suspension

More information

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. wide range of pipe clamps are available for various applications. Materials arbon Steel is used

More information

Service Entrance Cable Fittings

Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.

More information

Meter Swivels Insulated Unions Meter Sets Meter Accessories The Right Connection 1-800-654-3872 1-405-273-6302 www.centralplastics.com : Overview Georg Fischer Central Plastics entered the meter connection

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Com-Tray. Under Floor

Com-Tray. Under Floor Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting

More information

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS GUY-GRIP Dead-end NOMENCLATURE Please visit our web site at www.preformed.com for additional literature.guy-grip Dead-end Application Procedure - SP2045 Cross-over Marks: (A) Indicate starting point for

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

Specifications Electrical Metallic Tubing (EMT)

Specifications Electrical Metallic Tubing (EMT) T& Fittings Specifications Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-000 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 PART 1 GENERAL 1.01 DESCRIPTION A. Section includes requirements for an electrical grounding system, including electrodes, grounding rods, connectors, insulators, equipment grounding and

More information

thermoweld The Contractors Choice GREAT PRODUCTS GREAT SERVICE GREAT PEOPLE

thermoweld The Contractors Choice GREAT PRODUCTS GREAT SERVICE GREAT PEOPLE The Contractors Choice the Contractors Choice Founded in 1958, with locations in Tulsa and Broken Arrow, Oklahoma. is part of the Quality Brands of Continental Industries. TABLE OF CONTENTS THE PROCESS...4

More information

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Terminator The Terminator body is deep enough to provide an ample compound chamber

More information

SECTION INSULATED WIRE AND CABLE

SECTION INSULATED WIRE AND CABLE SECTION 16120 INSULATED WIRE AND CABLE PART 1 GENERAL 1.01 DESCRIPTION A. This section covers the contract item Insulated Wire and Cable, which includes the following items with accessories, and appurtenances:

More information

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED LB57 1-1/2 LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category LB57 Appleton/Oz Gedney Conduit Body, Electro Zinc Plated Dichromate Epoxy Powder Coated

More information

Suffix for Disc Material Size A B C I.D. O.D. B.C. Holes Black White

Suffix for Disc Material Size A B C I.D. O.D. B.C. Holes Black White Wet-R-Dri Valve A TA STYLE LIGHTWEIGHT COMPACT VERSATILE B I.D. Size Standard Model Detent Model Standard Material Max. Working Body Disc Pressure WD00 AL B. WD0 AL B. Aluminum WD00 GI B. WD0 GI B. Grey

More information

Meter Connection Products: Overview

Meter Connection Products: Overview : Overview Georg Fischer Central Plastics entered the meter connection business in 1955 with the design and introduction of the insulated meter swivel and insulated union. We understand the critical nature

More information

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction.

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction. S and ast Hub evice oxes UNILTS for use with Threaded Rigid onduit and IM. ll device boxes have ridge top construction. pplications ccommodate wiring devices such as switches and receptacles. Provide excellent

More information

Series 2000PV Mechanical Joint Restraint for PVC Pipe

Series 2000PV Mechanical Joint Restraint for PVC Pipe Series 2000PV Mechanical Joint Restraint for PVC Pipe Features and Applications: For restraining plain end PVC pipe at mechanical joint fittings and appurtenances Sizes 3 inch through 36 inch Sizes 42

More information

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application Introduction Designed for Indoor and outdoor applications Non-tension tap and splice applications Used

More information

Fig Beam Clamp Retaining Strap (B-Line B3367)

Fig Beam Clamp Retaining Strap (B-Line B3367) Fig. 69 - Beam Clamp Retaining Strap (B-Line B3367) Size Range: 3 /8"-16 thru 3 /4"-10 rod 4 (101.6mm) thru 16 (406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized

More information

SECTION 4 - SECONDARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

SECTION 4 - SECONDARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS 4. GENERAL SECONDARIES & SERVICES 4.- INDIVIDUAL PHASE SECONDARY OVERHEAD LINE EXTENSIONS 4.- SECONDARY AND SERVICE CABLE SPLICES 4.- INSULATED SERVICE ENTRANCE COMPRESSION CONNECTORS 4.- 4. POLE ATTACHMENTS

More information

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves TAPPING VALVE MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D. PVC--Also outlet sealed

More information

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers Design Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the American Standard Code for Pressure Piping. Hanger Design Pipe hangers are of advanced design

More information

Thermocouples and Accessories Product Catalog

Thermocouples and Accessories Product Catalog Thermocouples and Accessories Product Catalog 7282 N. Haggerty Rd. Canton, MI 48187 P. 734-451-8740 / F. 734-451-8741 www.inspec-inc.com 1 P a g e EXPERT CONTROL AND INSTRUMENTATION REPAIR Plastics Industry

More information

SECTION CHAIN-LINK FENCES AND GATES 02821/1

SECTION CHAIN-LINK FENCES AND GATES 02821/1 SECTION 02821 - CHAIN-LINK FENCES AND GATES 02821/1 PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Chain-Link Fences: 2. Gates: horizontal slide or swing. 3. Fences installed where

More information

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11

Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (Specifications for Installation) PES March 2008 Spec 11 Underground Residential Distribution (URD) Index General Discussion... 1-2 Description... 3-7 Drawings (Available

More information

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping

12.1 MUELLER TAPPING MATERIALS AND SPECIALTY VALVES. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves. MUELLER Stainless Steel Tapping MUELLER TAPPING MATERIALS AND SPECIALTY VALVES 12.1 Shaded area indicates change Rev. 7-16 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

Large cable sizes stronger than pipe/strut

Large cable sizes stronger than pipe/strut Legrand Seismic Wire Rope/Cable Bracing is the recommended seismic bracing for Legrand wire mesh and ladder tray systems. It is UL Listed, complies with all building codes and standards, and offers significant

More information

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe MEGALUG Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe Features and Applications: Sizes 3 inch through 54 inch Constructed of ASTM A536 Ductile Iron Torque Limiting Twist-Off Nuts Nominal

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

MGO INSULATED THERMOCOUPLES INDEX

MGO INSULATED THERMOCOUPLES INDEX MGO INSULATED THERMOCOUPLES INDEX PAGE General Information... M1 Part Numbering Examples... M4 Thermocouple Elements (MA)... M5 Leadwire Style Thermocouples (MB)... M6 Leadwire Style Thermocouples (MD,

More information

PTFE Pipe Slide Assemblies

PTFE Pipe Slide Assemblies PTFE Slide Assemblies Overview Application Anvil PTFE pipe slide assemblies are designed to support the pipe and provide for lateral and axial movement due to thermal expansion and contraction of the piping

More information

(Condensed from National Electric Code)

(Condensed from National Electric Code) WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,

More information

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves

UL / FM D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Sleeves and Crosses. MUELLER Tapping Valves UL / FM TAPPING VALVE SECTION Rev. 2-15 MUELLER Tapping Sleeves and Crosses Full range of Tapping Sleeves and Crosses to fit most types of pipe including cast iron, ductile iron, A-C, and cast iron O.D.

More information

The University of Texas at Austin September 30, 2011

The University of Texas at Austin September 30, 2011 SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATIONS PART 1 - GENERAL 1.1 SUMMARY A. This section governs the products and execution requirements relating to furnishing and installing grounding and

More information

hors Anc Eaton's B-Line series fasteners 183

hors Anc Eaton's B-Line series fasteners 183 183 Glossary Prefix - Description Screw Dia. Length Suffix ACB - Concrete Anchor Bolt 4 - #4 75-3 /4" AN - Acorn Nut ACPD - Bang-IT 6 - #6 81-13 /16" CH - Combo Head ACPW - Wood-Knocker 8 - #8 87-7 /8"

More information

Fixings, bonds and clamps

Fixings, bonds and clamps Square tape clamp Material 25 x 3mm Copper 0.12kg CT105-H 25 x 6mm Copper 0.30kg CT110-H 50 x 6mm Copper 0.60kg CT115-H Manufactured from high quality copper and aluminium alloys. Simple to install, providing

More information

A. Product Data shall be provided for each type of product indicated.

A. Product Data shall be provided for each type of product indicated. 32 31 13 CHAIN LINK FENCES AND GATES SECTION 1 GENERAL 1.1 SUMMARY This Section includes the following: 1. Chain Link Fences 2. Gates for Chain Link Fences. See electrical specifications for electrical

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

Material and Process. Specification

Material and Process. Specification s 146-67- 1 of 7 Document By: Title Name 1. Purpose 1.1 This document defines approved revision levels of Material and Process specifications used by Onboard Systems. This list is for supplier reference

More information

Copper and Copper Alloy Tube, Pipe and Fittings COPPER and COPPER ALLOY TUBE and PIPE Seamless Copper Pipe: Copper pipe is almost pure copper manufactured to the requirements of ASTM B 42 - Standard Specification

More information

Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free

Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free WAGO CAGE CLAMP Technology, Can Help Reduce Costs and Increase Safety in Your Applications! Contents Reduce Costs 4 Increase

More information

Welcome to Douglas County PUD

Welcome to Douglas County PUD Welcome to Douglas County PUD We are committed to providing the best possible utility services at the lowest possible cost consistent with sound business principles. To better serve you, please fill out

More information

HOLE SAMPLING & MONITORING. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

HOLE SAMPLING & MONITORING. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD HOLE SAMPLING & MONITORING MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD www..com HOLE SAMPLING & MONITORING TABLE OF CONTENTS HOLE SAMPLING & MONITORING OVERVIEW...2 SPLIT

More information

7Terminals and Splices

7Terminals and Splices Introduction Product Facts No need f inhibit agents, thanks to our dry crimp technique Terminating/splicing capabilities f stranded aluminum wire, plus splicing of aluminum wire to copper wire conducts

More information

Electric Service Standards

Electric Service Standards V: 1 of 6 A. Padmounted Requirements Complete requirements are contained in FPL specifications given to Customers for individual projects. Typical pad mounted transformer requirements include, but are

More information

ROOF MOUNT KIT OWNERS MANUAL

ROOF MOUNT KIT OWNERS MANUAL ROOF MOUNT KIT OWNERS MANUAL Made in the USA by: Primus Wind Power, Inc. 938 Quail St. Lakewood, CO 80215 Phone: (303) 242-5820 www.primuswindpower.com AIR is a trademark of Primus Wind Power, Inc. ROOF

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466 BUSWAY LOW VOLTAGE (POW-R-WAY III) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein

More information

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC Van Dam Street Long Island City, NY ELECTRIC METER SHOP DEPARTMENT CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 48-05 Van Dam Street Long Island City, NY 11101 ELECTRIC METER SHOP DEPARTMENT METER ENGINEERING SPECIFICATION MES-350 REVISION 3 June 2016 EFFECTIVE DATE

More information

PATHWAYS FOR COMMUNICATIONS SYSTEMS

PATHWAYS FOR COMMUNICATIONS SYSTEMS 270528 PATHWAYS FOR PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment for the complete installation of work called for in the Contract Documents. 1.2 SCOPE OF WORK A. This

More information

Suspension System Data Center Ceiling Solutions

Suspension System Data Center Ceiling Solutions Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"

More information

SECTION SLUICE GATES

SECTION SLUICE GATES SECTION 11100 SLUICE GATES PART 1--GENERAL Fill in the blank with a short description of sluice gate usage, i.e., for isolation of wastewater, or for tank drainage, or for control of water surface. 1.01

More information

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations TOLCO Fire Protection Support Systems Pipe Hangers Supports Seismic Bracing UL Listed FM Approved for Fire Sprinkler Installations Revision 12/06/2007 Catalog Forward This catalog has been created with

More information

CLASS I & II HEAVY DUTY EQUIPMENT CATALOG

CLASS I & II HEAVY DUTY EQUIPMENT CATALOG CLASS I & II HEAVY DUTY EQUIPMENT CATALOG 901 Sibley Highway Saint Paul, MN 55118-1792 651-455-7661 1-800-777-1230 GENERAL INFORMATION INTRODUCTION: THOMPSON LIGHTNING PROTECTION, INC. CAME INTO BEING

More information

SECTION TAPPING SLEEVES AND VALVES

SECTION TAPPING SLEEVES AND VALVES SECTION 33 12 16.17 TAPPING SLEEVES AND VALVES PART 1: GENERAL 1.01 SCOPE Furnish, install and test all tapping sleeves, tapping valves, and tapping saddles as shown on the Drawings. 1.02 RELATED WORK

More information

Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties

Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties Stainless steel describes a family of steels highly resistant to tarnishing and rusting that contain at least two

More information

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution DURA-BLOK rooftop supports BRTS-17 B-LINE SERIES DURA-BLOK A complete rooftop support solution DURA-BLOK rooftop solutions support DURA-BLOK supports are made of 100% recycled rubber and are designed to

More information

DURA-BLOK is made from 100% recycled rubber and qualifies for LEED credits. Reflective strips on both sides allow for easy product visibility.

DURA-BLOK is made from 100% recycled rubber and qualifies for LEED credits. Reflective strips on both sides allow for easy product visibility. is made from 100% recycled rubber and qualifies for LEED credits. Reflective strips on both sides allow for easy product visibility. Channels are through bolted on all sizes for added strength and a 1

More information

Technical Specification for Live Line Tap Connectors

Technical Specification for Live Line Tap Connectors Ergon Energy Corporation Limited Technical Specification for Live Line Tap ETS-06-01-01 Check this is the latest Process Zone version before use. Specification ETS 06-01-01 Ver 1 Contents 1. Purpose and

More information

DURA-BLOK Rooftop Supports

DURA-BLOK Rooftop Supports Cooper B-Line s new line of DURA-BLOK products gives you a versatile and long-term solution for all your roof top support needs. Designed with flexibility in mind, Dura-Blok is ideal for roof top support

More information

TUFFALOY. Resistance Welding Products. Leader in the Industry Since Catalog 2014

TUFFALOY. Resistance Welding Products. Leader in the Industry Since Catalog 2014 Catalog 2014 Resistance Welding Products Leader in the Industry Since 1937 Resistance Welding Equipment & Supplies Service Sales Consulting Seminars table of contents RESISTANCE WELDING PRODUCTS The little

More information

Dimensions in Millimeters (Inches) A Bushing Diameter. B Bushing Height

Dimensions in Millimeters (Inches) A Bushing Diameter. B Bushing Height Insulated Grounding for Threadless and Threaded RM IM GI-LS- and I-LS- Series - with luminum Lay-In-Lug for opper or luminum onductors. NE/E: pplications GI-LS Series insulated bushings fasten and ground

More information

Flexdip CYH112. Technical Information. Holder system for water and wastewater assemblies

Flexdip CYH112. Technical Information. Holder system for water and wastewater assemblies Technical Information Flexdip CYH112 Holder system for water and wastewater assemblies pplication Water treatment Wastewater treatment Plant design CYH112 is a modular holder system for sensors and assemblies

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

Steel Octagon Boxes & Ceiling Pans

Steel Octagon Boxes & Ceiling Pans 3 1 /4" ROUND CEILING PAN 4.0 CUBIC INCH CAPACITY 1 /2" DEEP CLAMPS IN BOTTOM TP266 Cat. # Cable Conduit Unit Qty. Wt. Lbs. Per 100 TP266 4 Cable 1 1 /2" 30 3 1 /4" OCTAGON OUTLET BOXES 9.0 CUBIC INCH

More information

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS Page no. :1 of 11 SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS Prepared by: Eng. T. Lev (-חתום-) Checked by: I. Bester (-חתום (- Approved by: Eng. Y. Samoocha (-חתום (- 1 Page no.

More information

CHEMICAL /4" 3/8" to 5/8" /8" 3/4" to 1-1/4" 1 10

CHEMICAL /4 3/8 to 5/8 /8 3/4 to 1-1/4 1 10 194 ASTM A193 GRADE B7 HIGH-STRENGTH CARBON, ZINC PLATED (ASTM B 633 YELLOW DICHROMATE) B7 (AISI 414) anchor rod is supplied with nuts meeting the requirements of ASTM Specification A 194, Grade 2H (ASTM

More information

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4 x 4 x 3/8 Brace. C8 x 4.25 Strut. WT9 x 17.5. Sign length minus Adjust to avoid interference with sign legend A Deck fascia A 6" Equal Equal 6" Sign length (L) varies 6 to 12 PLAN 0 CONNECTION (DECK FASCIA) Angle connection assembly F Face of concrete

More information

NUCLEAR. Nuclear Reactor Pressure Vessel Seals

NUCLEAR. Nuclear Reactor Pressure Vessel Seals NUCLEAR Nuclear Reactor Pressure Vessel Seals SEALING CONCEPT Technetics Group is the world s leading manufacturer of Nuclear Reactor Pressure Vessel (RPV) Closure Head Seals. In addition, Technetics Group

More information

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing MERCHANTS METALS SECTION 32 31 13 COLORBOND CHAIN LINK FENCE AND GATES 2014 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. DIVISION 01 - GENERAL REQUIREMENTS: Drawings, quality, product and performance requirements,

More information

Box Rail. Single Box Rail Bracket

Box Rail. Single Box Rail Bracket HANGERS & RAILS Box Rail Accordion Door Hangers Max. Door Weight (SWL) 450 lbs Meets ANSI/BHMA A156.14, Grade 1. Rail is carefully formed to give an even tread to hanger wheels. Packaging: Bundled without

More information

FLEXTRAY Wire Basket - Splicing Accessories

FLEXTRAY Wire Basket - Splicing Accessories D-7 B-Line series Cable Tray Systems Washer is staked to bolt, holding part stationary during installation Fewer parts to handle For use with all tray widths and sizes Finishes : EG, BLE BLE suffix indicates

More information

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) SECTION 13125 ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

DISCONTINUED CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number:

DISCONTINUED CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number: Catalog number: / / Electrical Module Finish See page 2 Specifications Dimensions Models 50 to 70 watt HID Medium Base Lamps 13 to 42 watt Compact Fluorescent 60 watt Incandescent 150 watt Halogen 27 LED

More information

Section 906. STRUCTURAL STEEL

Section 906. STRUCTURAL STEEL 906.01 Section 906. STRUCTURAL STEEL 906.01. General Requirements. Finished rolled shapes must be free from imperfections that affect strength and durability in accordance with ASTM A 6. Rolled shapes

More information

ROLLING RACK. Simple Security

ROLLING RACK. Simple Security Simple Security The graceful design and high security of the Rolling Rack has made this type of bike rack a standard for many schools and communities. The Rolling Rack can be used as a single-sided or

More information

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series

More information

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

MASTERSPEC - SHORT FORM. B. See Division 5 Section Metal Stairs for steel tube railings associated with metal stairs. SECTION 05721 - ORNAMENTAL RAILINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Glass supported railings. B. See Division 5 Section "Metal Stairs" for steel tube railings associated

More information

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version / Anchor HSA Fastening Stud anchor Technology Manual HSA Stud anchor Version 2015-09 09 / 2015 1 HSA Stud anchor Anchor version HSA Carbon steel with DIN 125 washe HSA-R Stainless steel A4 HSA-R2 Stainless

More information

GroundTrac. Installation Manual

GroundTrac. Installation Manual APPLICATION: The GroundTrac system is designed with a minimum amount of installed footings at greatly reduced labor. The system integrates with ordinary 1-1/2 schedule #40 galvanized water pipe. This ground

More information

SECTION SEISMIC CONTROL OSHPD

SECTION SEISMIC CONTROL OSHPD SECTION 01451 PART 1 - GENERAL 1.01 DESCRIPTION A. Provide all required seismic restraints and calculations in order to insure that the installation of all architectural, mechanical, and electrical equipment/components

More information

SECTION 18. AMERICAN General Index

SECTION 18. AMERICAN General Index SECTION 18 AMERICAN General Index General Index A Abbreviations Organizations...1-1 Standard, American...17-23 Abrasion Resistant Pipe...12-12 Accessories (See Joint Materials) American Flow Control Valves

More information

Aluminium Excellence Performance in Economical Way

Aluminium Excellence Performance in Economical Way OPPER CLAD Aluminium Excellence Performance in Economical Way www.jmv.co.in Leading The Nation Towards Electrical Safety With the growing industrialization, the demand of electrical safety is increasing

More information

TABLE OF CONTENTS BURNDY. Overhead Distribution TAP CONNECTORS H-3 - H-20 H-21 - H-40 H-41 - H-43

TABLE OF CONTENTS BURNDY. Overhead Distribution TAP CONNECTORS H-3 - H-20 H-21 - H-40 H-41 - H-43 BURNDY Overhead Distribution TABLE OF CONTENTS TAP CONNECTORS Mechanical (Bolted) Compression Transformer and Equipment H-3 - H-20 H-21 - H-40 H-41 - H-43 COMPRESSION SPLICES Service Entrance Neutral Jumper

More information

Bore Code 1 1/8" mm 121

Bore Code 1 1/8 mm 121 /8" (2) Bore Model Number Model Number Code Leave blank if none desired D 2 X MR Metric M See pages.7,.3 &.34 Bore Code /8" 2 28.5mm 2 T Series HOW TO ORDER Sound limiters: Rod end -LF Includes PTFE. Under

More information

CHAPTER 11 CONDUITS AND FITTINGS

CHAPTER 11 CONDUITS AND FITTINGS CONDUITS AND FITTINGS CHAPTER 11 CONDUITS AND FITTINGS The standards and requirements for conduits and fittings used for traffic control signal and lighting systems are presented in this chapter. 11.1

More information

CONDUITS AND FITTINGS

CONDUITS AND FITTINGS CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit

More information