2 Bypass Level Indicator-Mini / Content Table of content Bypass Level Indicator-Mini / Content Bypass Level Indicator-Mini / Functional description Bypass Level Indicator-Mini / key Bypass Level Indicator-Mini / key Bypass Level Indicator-Mini / key Bypass Level Indicator-Mini / key Bypass Level Indicator-Mini / Stainless steel PN Bypass Level Indicator-Mini / Stainless steel PN Bypass Level Indicator-Mini / Cylindrical float PN Bypass Level Indicator-Mini / Cylindrical float PN Bypass Level Indicator-Mini / Magnetic roller indicator Bypass Level Indicator-Mini / Scale Bypass Level Indicator-Mini / Level transmitter Bypass Level Indicator-Mini / Level transmitter Bypass Level Indicator-Mini / Level transmitter Bypass Level Indicator-Mini / Level transmitter Bypass Level Indicator-Mini / Level transmitter Bypass Level Indicator-Mini / Level transmitter Bypass Level Indicator-Mini / Magnetic switch Bypass Level Indicator-Mini / Magnetic switch Bypass Level Indicator-Mini / Magnetic switch Bypass Level Indicator-Mini / Magnetic switch Bypass Level Indicator-Mini / Isolation / Heat tracing Bypass Level Indicator-Mini / Isolation Bypass Level Indicator-Mini / Chamber end top Bypass Level Indicator-Mini / Chamber end top Bypass Level Indicator-Mini / Chamber end bottom Bypass Level Indicator-Mini / Process connection / Support bracket Bypass Level Indicator-Mini / Chamber end bottom mini 300
3 Bypass Level Indicator-Mini / Functional description Functional description Bypass level indicators form an integral part of the pressure vessel. Via two process connections a standpipe ( bypass ) is mounted to the side of a tank or vessel. Due to the direct connection the filling level in the bypass will always correspond exactly to the filling level in the vessel ( communicating display ). In the bypassing pipe a cylindrical float with a built-in magnetic system is contained. The concentrated magnetic field of the permanent magnet corresponds exactly to the filling level of the liquid in the bypass. In a contactless way the magnetic field transmits itself through the wall of the standpipe onto externally mounted displaying, recording and switching elements mini Design limits Specific gravity: Design pressure: Design temperature: 560 kg/m 3-1 bar... 6 bar -40 C C 301
4 Bypass Level Indicator-Mini / key Code 1 Key 1 - Version BNA 1 BMG 1 Bypass level indicator Bypass level indicator with level transmitter Code 2 Key 1 ( for process connection flange ) - Flange connection Key 1 ( for process connection other ) - Other process connection FE 1 FA 1 F 1 FS 1 Flange according to EN Flange according to ANSI Flange according to Flange according to drawing GM 1 NPTM 1 GN 1 NPTN 1 SE 1 OS 1 Female thread G Female thread NPT Male thread G Male thread NPT Welding stub end Without process side connections ( Code 3 not applicable ) Code 3 Key 1.1 ( only for flange ) / / - Flange connection Key 1.2 ( only for flange ) / / - Flange connection Key 1.3 ( only for flange ) / / - Flange connection Flange nominal bore Flange pressure rating Flange facing Code 3 Key 1 ( for process connection other ) - Size Threaded connection size Welding stub end size 1015-mini Example Code Key / 1.2 / / 2 / 3 / 4 / 5 / 6 / 7 / / 2 / 3 - Example BMG - FE - 25 / 16 / B1 - ALE / TP43B / V / K15 / EXIAG - DU - M - V / 40 / 2 - Black = not possible according to Atex / Blue = possible according to Atex Exia / Blue 1 = possible according to Atex Exia and Exd / Black 1 = possible according to Atex Exd 302
5 Bypass Level Indicator-Mini / key Code 4 Key 1 / / / / / / / - Electrical connection level transmitter Key 2 / / / / / / / - Control unit Key 3 / / / / / / / - Level transmitter tube material quality ALE ALF ALDA 1 AVA AVDA 1 AVM AVDM 1 DAAVDM 1 APA APB ABA K K68 DAALA DAAVDA 1 Aluminium terminal box 64 x 58 x 34 mm ( only without control unit ) Aluminium terminal box 80 x 75 x 57 mm Aluminium terminal box Ø 95 x 84 mm Stainless steel terminal box Ø 82 x 110 mm Stainless steel terminal box Ø 82 x 110 mm Stainless steel terminal box Ø 50 x 117 mm Stainless steel terminal box Ø 169 x 117 mm Stainless steel terminal box with LED display Ø 169 x 117 mm Polyester terminal box 80 x 75 x 55 mm Polyester terminal box 80 x 75 x 55 mm / Exm ABS terminal box 80 x 82 x 55 mm Connection cable Connection cable IP 68 ( G 3/8 ) Aluminium terminal box with LED display Ø 82 x 100 mm Stainless steel terminal box with LED display Ø 82 x 100 mm TP43A 1 TP5343A TP43B 1 TP5343B Ex TD35A 1 TD5335A TD35B 1 TD5335D Ex TP50AP 1 TP5350AP / PROFIBUS PA TP50BP 1 TP5350BP Ex / PROFIBUS PA TP50AF 1 TP5350AF / FOUNDATION TM Fieldbus TP50BF 1 TP5350BF Ex / FOUNDATION TM Fieldbus TMT181A 1 TMT181 TMT181B 1 TMT181 Ex ZMU 1 XT42SI Ex TAMX 1 Other control unit MST 1 Magnetostrictive / ma MSTB 1 Magnetostrictive / ma / Ex MSTH 1 Magnetostrictive / HART -Protocol MSTHB 1 Magnetostrictive / HART -Protocol / Ex V 1 Stainless steel Code 4 Key 4 / / / / / / / - Accuracy Key 5 ( only for connection cable ) / / / / / / / - Length of cable Key 6 ( only for connection cable ) / / / / / / / - Connection cable K5 1 K5HTF 1 K5HT 1 K10 1 K10HTF 1 K10HT 1 K15 1 K15HTF 1 K15HT 1 K1 1 K1HT 1 Accuracy 5 mm / C Accuracy 5 mm / C Accuracy 5 mm / C Accuracy 10 mm / C Accuracy 10 mm / C Accuracy 10 mm / C Accuracy 15 mm / C Accuracy 15 mm / C Accuracy 15 mm / C Accuracy 0.2 mm / C Accuracy 0.2 mm / C Length of cable in meter PVC 1 PVCB 1 SIL 1 PUR 1 RAD 1 PVC connection cable PVC connection cable with blue coating Silicone connection cable PUR connection cable Radox connection cable Code 4 Key 7 ( only for connection cable ) / / / / / / / - Connection cable option Key 8 / / / / / / / - Approvals level transmitter KA 1 KB 1 KC 1 KD 1 KE 1 KF 1 Shielded Shielded / oil-resistant Shielded / oil-resistant / halogen-free Oil-resistant Oil-resistant / halogen-free Halogen-free EXIAG EXIAGD EXDG 1 EXDGD 1 EXIADG 1 EXIADGD 1 Acc. to Exia, atmosphere gas Acc. to Exia, atmosphere gas and dust Acc. to Exd, atmosphere gas Acc. to Exd, atmosphere gas and dust Acc. to Exia and Exd, atmosphere gas Acc. to Exia and Exd, atmosphere gas and dust mini Example Code 1 / 2 / 3-1 / 2 / 3 / 4 / 5 / 6 / 7-1 / 2-1 / 2-1 / 2 / 3 Key MNB / SA1-3 / RU40 / N / 1 / PVCB / KA / EXIAG - ZVS / EX / PED Example Black = not possible according to Atex / Blue = possible according to Atex Exia / Blue 1 = possible according to Atex Exia and Exd / Black 1 = possible according to Atex Exd 303
6 Bypass Level Indicator-Mini / key Code 5 Key 1 - Electrical connection position of the level transmitter DO 1 DU 1 Electrical connection top mounted Electrical connection bottom mounted Code 6 Key 1 - Centre distance / Length of instrument M 1 L 1 Centre distance in mm Length of instrument in mm ( only for Instrument without process side connections ) Code 7 Key 1 / / - Bypass chamber material quality Key 2 / / - Bypass chamber outside diameter Key 3 / / - Bypass chamber wall thickness V 1 Stainless steel ( V4A ) 40 1 Ø mm Bypass chamber wall thickness in mm Code 8 Key 1 / / - Magnetic roller indicator Key 2 / / - Scale Key 3 / / - Mag. roller indicator sight extension MNA MNB 1 MNAN MNBN 1 MNAV MNBV 1 MNAVN MNBVN 1 Magnetic roller indicator MNA Magnetic roller indicator MNB ( Ex ) Mag. roller indicator MNAN over-roll-protected Mag. roller indicator MNBN over-roll-prot. ( Ex ) Magnetic roller indicator MNAV Magnetic roller indicator MNBV ( Ex ) Magnetic roller indicator MNAVN over-roll-prot. Mag. roller indicator MNBVN over-roll-prot. ( Ex ) SAK SA0 1 SA1 1 SA2 1 SA3 1 SA4 1 SV0 1 SV1 1 SV2 1 SV3 1 SV4 1 Scale in Aluminium with adhesive foil PV 1 Scale in Aluminium without engraving Scale in Aluminium with engraving in % Scale in Aluminium with engraving in cm Scale in Aluminium with engraving in inch. Scale in Aluminium with engraving acc. to customized table Scale in Stainless steel without engraving Scale in Stainless steel with engraving in % Scale in Stainless steel with engraving in cm Scale in Stainless steel with engraving in inch. Scale in Stainless steel with engraving acc. to customized table Acryl glass extension Code 9 Key 1 / / / / / / - Number of magnetic switches Key 2 / / / / / / - Magnetic switch Key 3 / / / / / / - Magnetic switch option 1015-mini Number of magnetic switches RU40 RUD40 RUV40 RUVD40 ALERU40 ALFRU40 Magnetic switch RU40 Magnetic switch RUD40 Magnetic switch RUV40 Magnetic switch RUVD40 Magnetic switch ALERU40 Magnetic switch ALFRU40 R22 1 N 1 Switch protective circuit with 22 ohm / 0.21 W resistor Switch protective circuit according to NAMUR EN Example Code Key / 1.2 / / 2 / 3 / 4 / 5 / 6 / 7 / / 2 / 3 - Example BMG - FE - 25 / 16 / B1 - ALE / TP43B / V / K15 / EXIAG - DU - M - V / 40 / 2 - Black = not possible according to Atex / Blue = possible according to Atex Exia / Blue 1 = possible according to Atex Exia and Exd / Black 1 = possible according to Atex Exd 304
7 Bypass Level Indicator-Mini / key Code 9 Key 4 / / / / / / - Length of cable Key 5 / / / / / / - Connection cable Key 6 / / / / / / - Connection cable option Length of cable in meter PVC 1 PVCB 1 SIL 1 PUR 1 RAD 1 PVC connection cable PVC connection cable with blue coating Silicone connection cable PUR connection cable Radox connection cable KA 1 KB 1 KC 1 KD 1 KE 1 KF 1 Shielded Shielded / oil-resistant Shielded / oil-resistant / halogen-free Oil-resistant Oil-resistant / halogen-free Halogen-free Code 9 Key 7 / / / / / / - Approvals magnetic switch EXIAG EXIAGD EXDG 1 EXDGD 1 EXIADG 1 EXIADGD 1 Acc. to Exia, atmosphere gas Acc. to Exia, atmosphere gas and dust Acc. to Exd, atmosphere gas Acc. to Exd, atmosphere gas and dust Acc. to Exia and Exd, atmosphere gas Acc. to Exia and Exd, atmosphere gas and dust Code 10 Key 1 / - Float Key 2 / - Float length ZVS 1 ZBS 1 Float in Stainless steel Float in Buna Acc. to float table on page 308 Code 11 Key 1 / - Instrument isolation Key 2 / - Electrical heat tracing AIT AHT SW Armaflex isolation AIT Armaflex isolation AHT Rock-wool isolation H75A H75B H150A H150B Electrical heat tracing 75 C Electrical heat tracing 75 C acc. to EExe Electrical heat tracing 150 C Electrical heat tracing 150 C acc. to EExe Code 12 Key 1 / / - Approvals / 1 Key 2 / / - Approvals / 2 Key 3 / / - Approvals / 3 EX Acc. to Ex PEDII 1 PEDIV 1 Acc. to PED97/23/EC category II Acc. to PED97/23/EC category IV GL 1 BV 1 DNV 1 ABS 1 GOST 1 Approval 3A Sanitary Standard Approval Germanischer Lloyd Approval Bureau Veritas Approval American Bureau of Shipping Approval GOST mini Example Code 1 / 2 / 3-1 / 2 / 3 / 4 / 5 / 6 / 7-1 / 2-1 / 2-1 / 2 / 3 Key MNB / SA1-3 / RU40 / N / 1 / PVCB / KA / EXIAG - ZVS / EX / PED Example Black = not possible according to Atex / Blue = possible according to Atex Exia / Blue 1 = possible according to Atex Exia and Exd / Black 1 = possible according to Atex Exd 305
8 Bypass Level Indicator-Mini / Stainless steel PN 6 BNA-..-../../..-M..-V/40/2-MN..-Z..S/.. Material quality: Centre distance M / Length of instrument L: Specific gravity: Design pressure: Design temperature: / / ( 316L / 316Ti ) mm 560 kg/m 3-1 bar... 6 bar -40 C C C = 80 Design B = 50 Chamber: Ø x 2.00 mm Process connection: Chamber end top: Chamber end bottom: Float: key page 302 Page Page Page 308 Option magnetic roller indicator / Page 310 M =... Aluminium or Stainless steel / Pocan -40 C C Option scale / Page 311 Aluminium / Stainless steel With adhesive foil / Engraving / Blank Option magnetic switch / Page Aluminium / Stainless steel -40 C C U =... Option level transmitter / Page Accuracy / Reed contacts: Accuracy / Magnetostrictive: Control unit: 5 / 10 / 15 mm 0.2 mm - Programmable - Hart-programmable / SIL2 - Profibus PA - Fondation Fieldbus ~ 30 Option electrical heat tracing / Page 322 Holding temperature: ~10 C / Frost protection Option instrument isolation / Page Isolation: Armaflex isolation / Rock-wool isolation 1015-mini ATEX* II 1G2D/2GD c Liquid temperature Ex max. 150 C II 2GD c key page * = The approval is dependent on the equipment combination 306
9 Bypass Level Indicator-Mini / Stainless steel PN 6 BNA-OS-L..-V40/2-MN..-Z.S.. Material quality: Centre distance M / Length of instrument L: Specific gravity: Design pressure: Design temperature: / / ( 316L / 316Ti ) mm 560 kg/m 3-1 bar... 6 bar -40 C C Design Chamber: Ø x 2.00 mm ~ 35 ~ 50 Process connection: Chamber end top: Chamber end bottom: Float: key page 302 Page Page Page 308 Option magnetic roller indicator / Page 310 A =... Aluminium or Stainless steel / Pocan -40 C C L = Option scale / Page 311 Aluminium / Stainless steel With adhesive foil / Engraving / Blank Option magnetic switch / Page Aluminium / Stainless steel -40 C C U =... Option level transmitter / Page Accuracy / Reed contacts: Accuracy / Magnetostrictive: Control unit: 5 / 10 / 15 mm 0.2 mm - Programmable - Hart-programmable / SIL2 - Profibus PA - Fondation Fieldbus ~ 45 Option electrical heat tracing / Page Holding temperature: ~10 C / Frost protection Option instrument isolation / Page Isolation: Armaflex isolation / Rock-wool isolation mini ATEX* II 1G2D/2GD c Liquid temperature Ex max. 150 C II 2GD c key page * = The approval is dependent on the equipment combination 307
10 Bypass Level Indicator-Mini / Cylindrical float PN 6 Cylindrical float PN 6 Stainless steel Float: Diameter [ mm ]: Design temperature [ C ]: Design pressure [ bar ]: ZVS34/../6/B Distance U ( see bypass level indicator figure ) Distance U with float stop: Distance U with Dämpfungsfeder: Float length - 20 mm Float length - 10 mm Float ZVS34/../6/B64 Length [ mm ] Weight [ g ] Float height above liquid [ mm ] Specific gravity of the liquid [ kg/m³ ] Cylindrical float PN 6 Buna Float: Diameter [ mm ]: Design temperature [ C ]: Design pressure [ bar ]: ZBS35/../6/M Distance U ( see bypass level indicator figure ) Distance U with float stop: Distance U with Dämpfungsfeder: Float length - 20 mm Float length - 10 mm Float ZBS35/../6/M1 Length [ mm ] Weight [ g ] mini Float height above liquid [ mm ] Specific gravity of the liquid [ kg/m³ ] key page ~ Position of the magnetic system 308
11 Bypass Level Indicator-Mini / Cylindrical float PN 6 Notes mini key page = Position of the magnetic system 309
12 Bypass Level Indicator-Mini / Magnetic roller indicator MNA / MNB MNAN / MNBN Housing: Aluminium anodized IP MNA / MNB / MNAN / MNBN Indication - Material quality: - Colour: Pocan White / Red End part: Sight cover - MNA / MNAN: - MNB / MNBN: Ryton, black Macrolon Glass L = M + 33 M =... MNAN / MNBN ( over-roll-protected ): -40 C C Roller rotation max ATEX / GOST / GL / BV / DNV / ABS MNAV / MNBV MNAVN / MNBVN Housing: Aluminium with Stainless steel covered IP MNAV / MNBV / MNAVN / MNBVN Indication - Material quality: - Colour: Pocan White / Red 1015-mini End part: Sight cover - MNAV / MNAVN: - MNBV / MNBVN: MNAVN / MNBVN ( over-roll-protected ): Ryton, black Macrolon Glass -40 C C Roller rotation max L = M + 33 M = ATEX / GOST / GL / BV / DNV / ABS key page
13 Bypass Level Indicator-Mini / Scale SAK / SA.. / SV.. SAK Scale: Angle profile: Scaling: Width: Adhesive foil ( black ) Aluminium in cm ( 0 cm.. 10 cm.. 20 cm.. 30 cm.. ) 40 mm -40 C C SA0 / SA1 / SA2 / SA3 / SA4 Scale: Angle profile: Scaling: Width: Engraved Aluminium Blank / % / cm / inch. /.. 40 mm -40 C C L = M + 33 SV0 / SV1 / SV2 / SV3 / SV4 Scale: Angle profile: Scaling: Width: Engraved Stainless steel Blank / % / cm / inch. /.. 40 mm -40 C C ATEX / GOST / GL / BV / DNV / ABS Magnetic roller indicator sight extension PV Material quality: Acryl glass Width: 35 mm Depth: 67 mm -40 C C on magnetic roller indicator mini ATEX / GOST / GL / BV / DNV / ABS key page
14 Bypass Level Indicator-Mini / Level transmitter Connection diagram BLACK BLUE BROWN VDC 4-20 ma ma BLACK BROWN VDC 4-20 ma BLUE 1 + ma BROWN BLACK R0Ω Rv without Control unit Control unit TP Control unit TD % (20 ma) BLACK BROWN 0% (4 ma) LED (Cal/Err.) 0% (4 ma) 100% (20 ma) BLUE BLACK BROWN BLUE 6 Bus 4-20 ma VDC + - ma ma VDC + - ma Control unit TP Control unit XT42SI Ex Control unit Magnetostrictive Some further data according to chapter Control Units 1011 SIL IEC / ATEX-Approval for accuracy K5.. / K10.. / K15..* 1015-mini II 1/2G II 1/2G Ex ia c IIC T6 - T4 Ex d ia c IIC T6 - T4 Liquid temperature Exia max. 180 C / Exd max. 120 C ATEX-Approval for accuracy K1..* II 1/2G II 2D of protection intrinsic safety Ex ia IIC switch bzw. temperature switch of protection intrinsic safety Ex ia IIC temperature probe of protection intrinsic safety Ex ia IIC with option /N ( NAMUR EN ) of protection moulding of protection moulding with option /N ( NAMUR EN ) of protection moulding with option /R22 ( resistor ) II 1/2G II 1/2G Ex ia c IIC T6 - T2 Ex ia IIC T6 - T2 II 1G II 2G Ex ia c IIC T6 - T3 bzw. Ex d ia c IIC T6 - T4 Ex td A21 c IP6* T80 C - T190 C bzw. T125 I i U i U i Ex ia IIC T4 - T2 Ex d IIC T4 U N U N U N 100 ma 28 V 15 VDC 250 VDC/AC 15 VDC 250 VDC/AC I i I i I N I N 100 ma 60 ma P SN 50 W/VA 60 ma 100 ma II 2G Ex d c IIC T6 - T4 P i 700 mw 700 mw P FN of protection intrinsic safety Ex ia IIC U i 30 V I i 200 ma P i 1000 mw Temperature class T6 T5 T4 - T2 Ambient temperature(t a ) -20 C C -20 C C -20 C C Liquid temperature(t F ) -20 C C -20 C C -20 C C key page * = The approval is dependent on the equipment combination 312
15 Bypass Level Indicator-Mini / Level transmitter ALF/../V/../..-M.. Housing: Cable entry: Level transmitter tube material quality: Minimum measures: Aluminium anodized M20 x 1.5 IP C C Stainless steel Tension strap T: 27 mm / L1: 40 mm / Ub: 50 mm 57 T = Accuracy 100 % L1 =... Accuracy: 5 / 10 / 15 mm Ambient temperature - K5 / K10 / K15: - K5HTF / K10HTF / K15HTF: - K5HT / K10HT / K15HT: Option control unit / Page C C -30 C C -40 C C M =... L = Ub + M + L1 Control unit: - Programmable - Hart-programmable / SIL2 - Profibus PA - Fondation Fieldbus 0 % Ub = ATEX / GOST / GL / BV / DNV / ABS ALDA/../V/../EXDG-M.. Housing: Cable entry: Level transmitter tube material quality: Minimum measures: Aluminium coated RAL 9006 M20 x 1.5 IP C C Stainless steel Tension strap T: 50 mm / L1: 40 mm / Ub: 50 mm 84 T = Accuracy Accuracy: 5 / 10 / 15 mm 100 % L1 =... Ambient temperature - K5 / K10 / K15: - K5HTF / K10HTF / K15HTF: - K5HT / K10HT / K15HT: Option control unit / Page 312 Control unit: -30 C C -30 C C -40 C C - Programmable - Hart-programmable / SIL2 - Profibus PA - Fondation Fieldbus 0 % M =... L = Ub + M + L mini ATEX / GOST / GL / BV / DNV / ABS 14 Ub =... key page
16 Bypass Level Indicator-Mini / Level transmitter DAALA/../V/..-M.. Electrical connection: Cable entry: Display: Current input: Level transmitter tube material quality: Minimum measures: Aluminium anodized M20 x 1.5 IP C C 4-digit LED display in red / Free scaling ma Stainless steel Tension strap T: 50 mm / L1: 40 mm / Ub: 50 mm 100 T = % L1 = Accuracy: 5 / 10 / 15 mm Ambient temperature - K5 / K10 / K15: - K5HTF / K10HTF / K15HTF: - K5HT / K10HT / K15HT: Option control unit / Page C C -30 C C -40 C C M =... L = Ub + M + L1 Control unit: - Programmable - Hart-programmable / SIL2 - Profibus PA - Fondation Fieldbus 0 % ATEX / GOST 14 Ub =... DAAVDA/../V/../EXIADG-M.. Electrical connection: Cable entry: Display: Current input: Level transmitter tube material quality: Minimum measures: Stainless steel electropolished M20 x 1.5 IP C C 4-digit LED display in red / Free scaling ma Stainless steel Tension strap T: 50 mm / L1: 40 mm / Ub: 50 mm 100 T = % L1 = Accuracy: 5 / 10 / 15 mm 1015-mini Ambient temperature - K5 / K10 / K15: - K5HTF / K10HTF / K15HTF: - K5HT / K10HT / K15HT: Option control unit / Page 312 Control unit: -30 C C ( Exd 120 C ) -30 C C ( Exd 120 C ) -40 C C ( Exd 120 C ) - Programmable - Hart-programmable / SIL2 - Profibus PA - Fondation Fieldbus 0 % M =... L = Ub + M + L1 ATEX / GOST 14 Ub =... key page
17 Bypass Level Indicator-Mini / Level transmitter AVA/../V/..-M.. Electrical connection: Cable entry: Level transmitter tube material quality: Minimum measures: Stainless steel A4 ( SS316 ) M20 x 1.5 IP C C Stainless steel Tension strap T: 50 mm / L1: 40 mm / Ub: 50 mm 110 T = Accuracy 100 % L1 =... Accuracy: 5 / 10 / 15 mm Ambient temperature - K5 / K10 / K15: - K5HTF / K10HTF / K15HTF: - K5HT / K10HT / K15HT: -30 C C -30 C C -40 C C M =... L = Ub + M + L1 Option control unit / Page 312 Control unit: - Programmable - Hart-programmable / SIL2 - Profibus PA - Fondation Fieldbus 0 % Ub = ATEX / GOST / GL / BV / DNV / ABS AVM/../V/../..-M.. Electrical connection: Cable entry: Level transmitter tube material quality: Minimum measures: Stainless steel A4 ( SS316 ) M16 x 1.5 IP C C Stainless steel Tension strap L1: 40 mm / Ub: 50 mm Accuracy Accuracy: 0.2 mm 100 % L1 =... Ambient temperature - K1: - K1HT: -40 C C -40 C C Control unit - MST / MSTB: - MSTH / MSTHB: - Programmable ma, VDC - Hart-programmable ma, VDC 0 % M =... L = Ub + M + L mini Ub =... ATEX / GOST / IECEX / SIL2 12 key page
18 Bypass Level Indicator-Mini / Level transmitter AVDM/../V/../EXIADG-M.. Electrical connection: Cable entry: Level transmitter tube material quality: Minimum measures: Stainless steel A4 ( SS316 ) M20 x 1.5 IP C C Stainless steel Tension strap L1: 40 mm / Ub: 50 mm Accuracy Accuracy: 0.2 mm 100 % L1 =... Ambient temperature - K1: ATEX temperature page 312 Control unit M =... L = Ub + M + L1 - MSTB: - MSTHB: - Programmable ma, VDC - Hart-programmable ma, VDC 0 % Ub =... ATEX / GOST / IECEX / SIL2 12 DAAVDM/../V/../EXIADG-M.. Electrical connection: Cable entry: Level transmitter tube material quality: Minimum measures: Stainless steel A4 ( SS316 ) M20 x 1.5 IP C C Stainless steel Tension strap L1: 40 mm / Ub: 50 mm Accuracy Accuracy: 0.2 mm 100 % L1 =... Ambient temperature - K1: ATEX temperature page mini Control unit - MSTB: - MSTHB: - Programmable ma, VDC - Hart-programmable ma, VDC 0 % M =... L = Ub + M + L1 Ub =... ATEX / GOST / IECEX / SIL2 12 key page
19 Bypass Level Indicator-Mini / Level transmitter mini key page
20 Bypass Level Indicator-Mini / Magnetic switch Connection diagram 1 SWITCH POINT 1 SWITCH POINT recommended wiring for PLC input 1 SWITCH POINT Protective circuit according to BLUE EN BLUE 1 BLUE 1 10K BROWN BLACK 2 3 BROWN BLACK Ohm BROWN 2 1K 10K BLACK 3 Change over Change over with resistor Change over with NAMUR EN SIL IEC / ATEX* 1015-mini II 2G II 2D Ex ia IIC T6 - T1 Ex td A21 IP6* T80 C - T300 C Liquid temperature Exia max. 180 C / Exd max. 120 C II 2G II 2D of protection intrinsic safety Ex ia IIC switch bzw. temperature switch of protection intrinsic safety Ex ia IIC temperature probe of protection intrinsic safety Ex ia IIC with option /N ( NAMUR EN ) of protection moulding of protection moulding with option /N ( NAMUR EN ) of protection moulding with option /R22 ( resistor ) Ex d IIC T6 - T4 Ex td A21 IP6* T80 C - T120 C I i U i U i U N U N U N 100 ma 28 V 15 VDC 250 VDC/AC 15 VDC 250 VDC/AC I i I i I N I N 100 ma 60 ma P SN 50 W/VA 60 ma 100 ma P i 700 mw 700 mw P FN key page * = The approval is dependent on the equipment combination 318
21 Bypass Level Indicator-Mini / Magnetic switch RU40/../../../.. RU40/../../../../EXIAG Housing: Ambient temperature - with PVC connection cable: - with Silikon connection cable: - with PUR connection cable: - with Radox connection cable: Aluminium anodized IP 65 Free positionable on the chamber -20 C C -40 C C -40 C C -35 C C 22 Switch function Switch point Function: Change over Switch behaviour: Switching capacity: Switching capacity / ATEX Exia: Switching hysteresis: Bistable 230 V / 0.5 A / 40 VA Exia 100 ma / Exia NAMUR 60 ma 5 mm... 7 mm ~ 100 Options - Switch option.. /R22: - Switch option.. /N: Resistor 22 Ohm / 0.21 W NAMUR EN ATEX / GOST / GL / BV / DNV / ABS / SIL1 RUD40/../../../../EXDG Housing: Aluminium anodized IP 65 Free positionable on the chamber - with PVC connection cable: - with Silikon connection cable: - with PUR connection cable: - with Radox connection cable: -20 C C -40 C C -40 C C -35 C C 22 Switch point Switch function Function: Switch behaviour: Switching capacity: - NAMUR EN 60947: - with resistor: Switching hysteresis: Options - Switch option.. /R22: - Switch option.. /N: Change over Bistable U N 250 V / P SN 50 W/VA / P FN 700 mw U N 15 VDC / I N 60 ma U N 250 V / I N 100 ma 5 mm... 7 mm Resistor 22 Ohm / 0.21 W NAMUR EN ~ mini ATEX / GOST / GL / BV / DNV / ABS / SIL1 key page
22 Bypass Level Indicator-Mini / Magnetic switch RUV40/../../../.. RUV40/../../../../EXIAG Housing: Stainless steel IP 68 Free positionable on the chamber Ambient temperature - with PVC connection cable: - with Silikon connection cable: - with PUR connection cable: - with Radox connection cable: -20 C C -40 C C -40 C C -35 C C Switch point 22 Switch function 69 Function: Switch behaviour: Switching capacity: Switching capacity / ATEX Exia: Switching hysteresis: Change over Bistable 230 V / 0.5 A / 40 VA Exia 100 ma / Exia NAMUR 60 ma 5 mm... 7 mm ~ Options - Switch option.. /R22: - Switch option.. /N: Resistor 22 Ohm / 0.21 W NAMUR EN ATEX / GOST / GL / BV / DNV / ABS / SIL1 RUVD40/../../../../EXDG Housing: Aluminium anodized IP 65 Right or left at the magnetic roller indicator Ambient temperature - with PVC connection cable: - with Silikon connection cable: - with PUR connection cable: - with Radox connection cable: -20 C C -40 C C -40 C C -35 C C 22 Switch function Switch point 1015-mini Function: Switch behaviour: Switching capacity: - NAMUR EN 60947: - with resistor: Switching hysteresis: Options - Switch option.. /R22: - Switch option.. /N: Change over Bistable U N 250 V / P SN 50 W/VA / P FN 700 mw U N 15 VDC / I N 60 ma U N 250 V / I N 100 ma 5 mm... 7 mm Resistor 22 Ohm / 0.21 W NAMUR EN ~ ATEX / GOST / GL / BV / DNV / ABS / SIL1 key page
23 Bypass Level Indicator-Mini / Magnetic switch ALERU40/.. ALERU40/../EXIAG Housing: Cable entry: Aluminium anodized M20 x 1.5 IP 65 Free positionable on the chamber -40 C C Switch function Switch point Function: Change over 30 Switch behaviour: Switching capacity: Switching capacity / ATEX Exia: Switching hysteresis: Bistable 230 V / 0.5 A / 40 VA Exia 100 ma / Exia NAMUR 60 ma 5 mm... 7 mm ~ 155 Options - Switch option.. /R22: - Switch option.. /N: Resistor 22 Ohm / 0.21 W NAMUR EN ATEX / GOST / GL / BV / DNV / ABS / SIL1 ALFRU40/.. ALFRU40/../EXIAG Housing: Cable entry: Aluminium anodized M20 x 1.5 IP 65 Free positionable on the chamber -40 C C Switch function Switch point 39 Function: Change over Switch behaviour: Switching capacity: Switching capacity / ATEX Exia: Switching hysteresis: Options - Switch option.. /R22: - Switch option.. /N: Bistable 230 V / 0.5 A / 40 VA Exia 100 ma / Exia NAMUR 60 ma 5 mm... 7 mm Resistor 22 Ohm / 0.21 W NAMUR EN ~ mini ATEX / GOST / GL / BV / DNV / ABS / SIL1 key page
24 Bypass Level Indicator-Mini / Isolation / Heat tracing AIT AHT Armaflex isolation AIT Material quality: Fire behaviour: Cellular plastic based on synthetic rubber Self-extinguishing, not drippy, not flamable C =... Nominal thickness: UV-resistance: Armaflex isolation AHT Material quality: Fire behaviour: Nominal thickness: UV-resistance: Self-regulating antifreeze heat tracing : Terminal box: Protective shell: Power supply: Power output: Holding temperature: Steam-flushing: : 32 mm -50 C C No Cellular plastic based on synthetic rubber Self-extinguishing, not drippy, not flamable 25 mm -50 C C Yes H..A H..B H75A H75B acc. to EExe / T4 GFK black with cable entry M25 Fluorpolymer 230V AC 76 W/m at 10 C ~10 C / Frost protection ( 32 mm Isolation necessary ) No -40 C C ATEX / DNV U =... M =... B =... Self-regulating antifreeze heat tracing : Terminal box: Protective shell: Power supply: Power output: Holding temperature: Steam-flushing: Minimale : H150A H150B acc. to EExe / T2 GFK black with cable entry M25 Fluorpolymer 230V AC 50 W/m at 10 C ~10 C / Frost protection ( 32 mm Isolation necessary ) Yes -40 C C ATEX / DNV mini key page
25 Bypass Level Indicator-Mini / Isolation SW Rock-wool isolation SW Material quality: Rock-woll with crome-nickel cover ( Removable ) C =... Nominal thickness: UV-resistance: ~50 mm -50 C C Yes U =... M =... B = mini key page
26 B Z Z B B Z B Z Z Z B B B B B Y Z B Z Z B B B B Bypass Level Indicator-Mini / Chamber end top Chamber end top BA BB BC BD Tube cap Tube plate Tube plate with vent plug G.. Tube plate with vent plug NPT.. OFF ON Y Z BE BF BG BH Tube plate with vent welding stub end Tube plate with vent flange Tube plate with vent ball valve Tube plate with vent needle valve BI BJ BK BL Flanged connection Flanged connection with vent plug G.. Flanged connection with vent plug NPT.. Flanged connection with vent welding stub end 1015-mini Z OFF ON B Y Z Y Z BM BN BO Flanged connection with vent flange Flanged connection with vent ball valve Flanged connection with vent needle valve key page
27 Bypass Level Indicator-Mini / Chamber end top Chamber end top Pressure rating 6 / 150# B Y Z Measure in ~ mm Tube cap Tube plate Tube plate with vent plug G1/ Tube plate with vent plug NPT1/ Tube plate with vent welding stub end Tube plate with vent flange Tube plate with vent ball valve G Tube plate with vent needle valve G Flanged connection Flanged connection with vent plug G1/ Flanged connection with vent plug NPT1/ Flanged connection with vent welding stub end Flanged connection with vent flange Flanged connection with vent ball valve G Flanged connection with vent needle valve G mini key page
28 Bypass Level Indicator-Mini / Chamber end bottom Chamber end bottom U =... W U =... W U =... W U =... UA UB UC UD Tube plate Tube plate with drain plug G.. Tube plate with drain plug NPT.. Tube plate with drain welding stub end W U =... W V U =... ON OFF UE UF UG W V U =... Tube plate with drain flange Tube plate with drain ball valve Tube plate with drain needle valve W U =... W U =... W U =... W U =... UH UI UJ UK Flanged connection Flanged connection with drain plug G.. Flanged connection with drain plug NPT.. Flanged connection with drain welding stub end 1015-mini W U =... W V U =... ON OFF UL UM UN W V U =... Flanged connection with drain flange Flanged connection with drain ball valve Flanged connection with drain needle valve key page
29 Bypass Level Indicator-Mini / Chamber end bottom Chamber end bottom Pressure rating 6 / 150# U V W Measure in ~ mm Tube plate... S - - Tube plate with drain plug G1/2... S - 20 Tube plate with drain plug NPT1/2... S - 30 Tube plate with drain welding stub end... S Tube plate with drain flange... S Tube plate with drain ball valve G... S Tube plate with drain needle valve G... S Flanged connection... S - 30 Flanged connection with drain plug G1/2... S - 35 Flanged connection with drain plug NPT1/2... S - 65 Flanged connection with drain welding stub end... S Flanged connection with drain flange... S Flanged connection with drain ball valve G... S Flanged connection with drain needle valve G... S Process connection / Support bracket Bypass Level Indicator-Mini / Process connection / Support bracket C ~ 80 C = 80 C = 80 C = 80 CA CC CD CE Welding neck flange ( Standard ) Blind flange Female thread Male thread C = mini CF Welding stub end Support bracket HE-4840 ( recommended for M 2000 mm ) key page S = Depending on the Float length 327
Level Sensors 1001 Table of contents
Table of contents Index Table of contents 4 Description and function 5 Certificates / Approvals 6-7 Level Sensors 1001 Stainless steel DN10 to DN500 8 Brass DN10 to DN80 9 Titanium DN10 to DN500 10 Alloy
More informationMagnetic float switch For vertical installation Model FLS for nuclear power plants
Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost
More informationMAGNETIC FLOAT SWITCHES
MAGNETIC FLOAT SWITCHES Magnetic Float Switches / Content Table of content Magnetic Float Switches / Content... 60 Magnetic Float Switches / Functional description... 61 Magnetic Float Switches / key...
More informationKDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...
All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : 0.1-1 l/h... 20-200 l/h water 5 - Nl/h... 600-6000 Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection:
More informationMeasuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600
Bypass Level Indicators ATEX or GL Approval measuring monitoring analysing NBK -ATEX,-GL -03, -06, -07, -10 Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart Pressure: max.
More informationO O Pressure: max. PN 100 / Class 600. O O Temperature: -40 C C (ceramic rollers) 0 C C (PP-rollers)
ypass Level Indicators ATEX or GL Approval measuring monitoring analysing NK -ATEX,-GL -03, -06, -07, -10 O O Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart O O Pressure:
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output
More informationPlastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases
Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or
More informationLiquid level switch BW 17
KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output
More informationILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma
More informationTSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max
Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE
SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE C20 C21 C26-2 C26-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration
More informationTTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma
Thermocouple Thermometers Ignition Protection Exd measuring monitoring analysing TTL-Exd T2 O O Measuring ranges: max. 1100 C OO NiCr-Ni or Fe-CuNi thermocouples OO Output: sensor or analogue 4-20 ma O
More informationPressure transducers DMU 02 Vario (flush)
Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load
More informationGlass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures
BPG 42 The BPG range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,
More informationTSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max
Flap Flow Meter for Liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless
More informationVisual Level Indicators VLI
WEKA Visual Level Indicators VLI Certified according ISO 9001:2000 Certified according PED 97/23/EC Member of the Group Certified according ATEX 94/9/EC Principles of design Single-pole Magnet System The
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More information8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.
SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional
More informationELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200
ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200 The GRD 4200 is an electronic earthing equipment for tankers during loading and unloading operations of flammable liquids in places with danger of explosion.
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationMechatronic pressure measurement. Applications. Special features. Description
Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data
More informationSPRING LOADED THERMOCOUPLE CONFIGURATIONS
SPRING LOADED THERMOCOUPLE CONFIGURATIONS FOR USE WITH THERMOWELLS II 3G Ex na/nl TCRN/WN/TN S30 S31 S36-1 S36-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration guarantees
More informationPressure - Process pressure
Pressure Process ressure Pressure - Process ressure Overview 126 VEGABAR 14, 17 128 VEGABAR 42 132 VEGABAR 52, 53, 54 134 Accessory 140 Dimensions 142 AL-EN - 125 Pressure Process ressure VEGABAR 10/40/50:
More informationBM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS
GUIDED WAVE RADAR LEVEL INSTRUMENTS DESCRIPTION The microwaves impulses at high frequency travel through a stainless steel guide and they are reflected on the surface of the fluid to analyze. The period
More informationThermocouple for Flue Gas Temperature Measurements,
Electrical Temperature Measurement Thermocouples for Flue Gas Temperature Measurements Model TC81 with Thermowell Model TW81 WIKA Data Sheet TE 65.81 Applications Blast furnaces, air heaters Red-heat and
More informationProcess Inline Filter, Change-Over
Process Inline Filter, Change-Over -503-130x -520x 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL Inline filters, types PRFL and duplex inline filters are designed for process engineering and chemical plants.
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationFlow Measurement SITRANS F M
Overview The MAG is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. Benefits Wide range of sizes: DN 15 to DN 2000 (½ to 78 ) The flexible design
More informationData Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.
Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationDigital E3 Modulevel Liquid Level Displacer Transmitter
Digital E3 Modulevel Liquid Level Displacer Transmitter D E S C R I P T I O N The Digital E3 Modulevel is an advanced, intrinsically safe two-wire instrument utilizing simple buoyancy principle to detect
More informationSITRANS T measuring instruments for temperature
Technical description Siemens AG 2008 Design Function A resistance thermometer comprises Measuring resistor the measuring resistor (metal; platinum, Pt or nickel, Ni) and Measuring resistors the mounting
More informationAccessories for Sample Gas Probe GAS 222
Accessories for Sample Gas Probe GAS 222 Sample tubes Downstream filters Capacitive vessel In-situ filters Cal gas connections Pneumatic actuators Extensions Adapter flanges 3/2-way-solenoid valves Blowback
More informationPro-V Multivariable Flowmeter Model M23 Insertion Vortex
Pro-V Multivariable Flowmeter Model M23 Insertion Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationDiaphragm seal with flange connection Cell-type with extended diaphragm Model
Diaphragm seals Diaphragm seal with flange connection Cell-type with extended diaphragm Model 990.35 WIKA data sheet DS 99.30 for further approvals see page 7 Applications Aggressive, highly viscous, crystallising
More informationRHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits
RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty
More informationOmnigrad M TR47, TR48
Technical Information Omnigrad M TR47, TR48 Hygienic, modular RTD assembly for weld-in installation Various process connections and fast response time Application All hygienic applications for food, pharmaceutical
More informationDiaphragm seal with flange connection With internal diaphragm, threaded design Model
Diaphragm seals Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.12 WIKA data sheet DS 99.31 for further approvals see page 7 Applications Aggressive, contaminated,
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet
More informationFLUIDISTOR GAS FLOWMETER GD 100 (EX)
FLUIDISTOR GAS FLOWMETER GD 100 (EX) for measuring of all technical and medical gases DN25 - DN400 Oscillating measuring principle, without moving parts Resistent to dirt, e.g. oil and rust residues in
More informationSolar Flat Plate Thermal Collector
Solar Flat Plate Thermal Collector 1 OBJECTIVE: Performance Study of Solar Flat Plate Thermal Collector Operation with Variation in Mass Flow Rate and Level of Radiation INTRODUCTION: Solar water heater
More informationTRICOR Series TCM Coriolis Mass Flow Meters. Technical Datasheet
TRICOR Series Coriolis Mass Flow Meters Technical Datasheet TRICOR - Coriolis Mass Flow Meters Description The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors
More informationSentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications
GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available
More informationSho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E
Data Sheet Sho-Rate TM "50" Model 1350E and Sho-Rate TM "150" Model 1355E Ten-to-one rangeability Heavy-wall, precision bore, borosilicate glass metering tubes A wide range of scales on the metering tube
More informationWEKA. Visual Level Indicators VLI
WEKA Visual Level Indicators VLI Principles of design Single-pole Magnet System The WEKA VLI operating principle is based on the use of a permanent bar magnet system which ensures the safe and reliable
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationWP-SDC COPPER CAN REGISTER WOLTMAN WATER METER
WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial
More informationALUBOX Series Junction boxes in IP66 aluminium alloy
UBOX Series Junction boxes in IP aluminium alloy > ENCLOSURES IP UBOX Series UBOX-EX Series Dimensions () Screw for attaching cover Earthing screws Weight (Kg) 00 x 00 x 59 n 2 M5x0 n M4x 0,290 /32 53.00
More informationRotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions
process measurement solutions 3 Rotameter Series 3 glass tube variable area flowmeter Data sheet 70 A range of quality glass tube V.A. flowmeters for general purpose & industrial applications Robust construction
More informationIndustrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series
Industrial Electrolytic Conductivity Cells for UDA2182 Series and APT Series 70-82-03-14 June 08 Page 1 of 8 Specification Main Overview The specification of an Electrolytic Conductivity Cell requires
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationTEMPERATURE SWITCHES AND THERMOSTATS
TEMPERATURE SWITCHES AND THERMOSTATS Our temperature switches and thermostats are ideal for applications where the end user is looking for highly accurate control across a wide range of operating temperatures.
More informationOver pressure Switching pressure difference (typical) Lower range Upper range
Allfluid pressure switches electromechanical actuated -... 63 bar, G/2 For Ex zones and 2 (gases) as well as Ex zones 2 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold
More informationFlow Assembly for ph and Redox Sensors FlowFit P CPA 240
Technical Information TI 179C/07/en Flow Assembly for ph and Redox Sensors FlowFit P CPA 40 ph flow assembly for demanding processes with high requirements. Sensor holder with three electrode mounting
More informationFieldbus Systems. Fieldbus System: CC-Link
Fieldbus Systems Fieldbus System: CC-Link CC-Link is the most dominant and fastest growing fieldbus technology in Asia. The open network is supported by the global CC-Link partner association CLPA, which
More informationMS50 Buoyancy level switch. K-TEK products. Measurement made easy. Features. Typical applications
Data Sheet DS/MS50-EN Rev. X MS50 Buoyancy level switch K-TEK products Measurement made easy Single Float Multi-Float Features Up To Six SPDT Switches Per Unit (NO & NC Contacts) Interface & Total Level
More informationOPTIMASS 7400 Technical Datasheet
OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used
More informationSURFACE TEMPERATURE SENSORS
SURFACE TEMPERATURE SENSORS These sensors are thermocouples and resistance thermometers for surface temperature measurement of objects. C400 R400 Magnet sensors measurement and monitoring of objects such
More informationShur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual
Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual P/N 1000006053 Rev E $7%$QDO\WLFV// //& 733 Dairy Rd. Parkton, Md. 21120 www.atbanalytics.com (410) 733-6365 Table of Contents Chapter 1: Getting
More informationDorot Irrigation Meter
DIM-A Irrigation Meter Application The DIM meter is designed for agriculture control applications. The turbine is located at the top of the pipe. Major section of the pipe is free for water flow. Features
More informationProduct Datasheet July Liquid Ultrasonic Flow Meters. Daniel 3812 Liquid Ultrasonic Flow Meter
Liquid Ultrasonic Flow Meters Daniel 3812 Liquid Ultrasonic Flow Meter TM Daniel 3812 Liquid Ultrasonic Flow Meter A Reliable and Economical Solution for Liquid Products Measurement Daniel 3812 Liquid
More informationABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1
Turbine Meter PTF Wide flow range up to :1 Intrinsically Safe and Flameproof versions available increases range of applications Excellent linearity and repeatability meets fiscal metering standards Linear
More informationOmnigrad T TST310. Technical Information. RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring
Technical Information Omnigrad T TST310 RTD thermometer Can be screwed in or inserted With fixed connected cable and anti-kink spring Application The resistance thermometer is specially suited to temperature
More informationCompact cylinders ADNGF, standard port pattern
Key features and type codes At a glance With guide rod and yoke plate ADNGF- With guide rod, yoke plate and through piston rod ADNGF- -S2 Cushioning types Mode of operation Application Cushioning P The
More informationLBHF LBHS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K. Ex d IIC U DIP A21
OPEN BENDS AND PULLING BOXES Explosion Proof Electrical Equipment Ex Conduit fittings Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D
More informationAT9000 Advanced Transmitter Absolute Pressure Transmitters
No. SS2-GTX00A-0500 AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent
More informationNRF CAPACITANCE LEVEL TRANSMITTER
NRF CAPACITANCE LEVEL TRANSMITTER Flow Pressure Level Temperature measurement monitoring control N2 Rigid and Suspended Designs Compact Microprocessor Based Designs High Accuracy NPT Threaded and Tri-Clamp
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 May 2009 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationFor highest levels of purity
For highest levels of purity Gas purification systems www.airliquide.de Individual gas purification... versatile, quick and clean Proven technology For several decades, Air Liquide has been offering you
More informationFunctional safety in the process industry
Functional safety in the process industry You want that feeling of security. You require uninterrupted production. We bring you safety and reliability. Our expertise Your advantage Page 3 SIL Safety Integrity
More informationnicrom e l e c t r o n i c
G E N E R A L High Performance Thick Film Resistors C A T A L O G 3 Nicrom Electronic Via Roncaglia CH - 6883 Novazzano SWITZERLAND Phone : ++4 () 9 68 99 86 Fax : ++4 () 9 68 99 86 info@nicrom-electronic.com
More informationINDUSTRIAL THERMOMETERS
JJ SIKA thermometers for industry and marine sector JJ Special versions and accessories JJ SIKA thermometers for heating, air conditioning and ventilation (HVAC) INDUSTRIAL THERMOMETERS Contains products
More informationVERIS Accelabar. Superior Flow Measurement Accuracy
VERIS Superior Flow Measurement Accuracy Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. ...A New Idea in Flow
More informationSPECIFICATIONS: If your preferred product configuration is not shown, please contact our sales representative for custom design.
NEW! Series TK SPECIFICATIONS: CONTACT RATING: 200mA / 1.5A @ 5~30VDC. ELECTRICAL LIFE: 1 million cycles at full load. CONTACT RESISTANCE: 20m-ohms max. INSULATION RESISTANCE: 600VDC 10M-ohms min. ESD
More informationFLOWRATE MEASURE PROBE DEBIX
IX serie - For pipes: ND 15 up to ND 3000 - Very low pressure loss - Flow = (f) P - For liquids, gazs and steams - Permanent accuracy ± 1% - Excellent repeatability: 0.1 % - Proof against impurities -
More informationElectronic Master - Printed Copies Uncontrolled - Rosemount Proprietary
Rosemount DP Flow Design & Operations 5601 North 71 st Street Boulder, CO 80301 Tel (303) 530-9600 Fax (303) 530-7064 Technical Documentation for CE Marking Pressure Accessories Manufacturer: Rosemount
More information20 A / 32 A / 63 A / 125 A / 200 A
METAL DECONTACTOR 20 A / / 63 A / 125 A / 200 A II2 G D Ex IIC WATER- AND DUST-TIGHT INTEGRATED LOAD-BREAK SWITCH IN ON/OFF POSITIONS BY KEYING AXIS DX contactors are signed for hazardous areas, with protection
More informationPre-Insulated Tubing Bundles
www.swagelok.com Pre-Insulated Tubing undles Electric-Traced and Steam-Traced Features Simplified field installation 1/8 to 3/4 in. and 6 to 12 mm seamless or welded tubing sizes 316 / 316L stainless steel,
More informationSITRANS L Level instruments
Overview Configuration is a guided wave radar transmitter for short and medium range level, level/interface and volume measurement of liquids and solids. It is unaffected by changes in process conditions,
More informationDML-Series. Pelton wheel flow meter
DML-Series Pelton wheel flow meter Flow meter manufacture As a specialist in flow measurement technology, TrigasDM supplies high-quality measuring instruments, electronics and calibrators for liquids and
More informationKnot Wheel Brushes WHEEL BRUSHES
W HE E L B RU S H E S 4 5 Knot Wheel Brushes Knot Wheel Brushes Knot wheel brushes for grinders, angle grinders and stationary machines used in the preparation and reworking of bolt fillet and butt welds.
More informationDiaphragm seal with flange connection With internal diaphragm Model
Diaphragm seals Diaphragm seal with flange connection With internal diaphragm Model 990.26 WIKA data sheet DS 99.26 for further approvals see page 7 Applications Aggressive, highly viscous, crystallising
More informationDiaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume
Pressure Diaphragm seal with flange connection With internal diaphragm, threaded design Model 990.41, large working volume WIKA data sheet DS 99.32 for further approvals see page 7 Applications Aggressive,
More informationWeighing Electronics. SIWAREX - PLC-based weighing modules SIWAREX FTC. Overview
Weighing Electronics Siemens AG 01 Overview Application The weighing module is the optimum solution wherever high demands are placed on continuous weighing procedures. Thanks to its outstanding measuring
More informationCompact flue gas analyser: testo 300 M-I
220 Compact flue gas analyser: testo 300 M-I PC analysis Prints Small memory -------------------- testo 300-I -------------------- 16.07.2001 09:36:22 C Quick flue gas checks are of interest for all industrial
More informationWing Union/Hammer Union Pressure Sensors Models 434, 435, Issue 3. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION
Wing Union/Hammer Union Pressure Sensors Models 434, 435, 437 32301963 Issue 3 Datasheet Model 434 with cage not pictured. DESCRIPTION Models 434/435/437 Wing Union/Hammer Union Pressure Sensors are designed
More informationDiffused Aeration Piping Equipment
1.0 General 1.1. The specifications in this section include all components of the Diffused Aeration System with the exception of the individual diffuser units. Refer to additional specification sections
More informationSafeSite LED Bulkhead / Wallpack - ATEX / IECEx for Indoor and Outdoor Industrial Applications
for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 www.dialight.com MDEXWPBHEUX001_D Features & Benefits L70 rated for >100,000
More informationWLC60 Heavy Duty LED Light
Datasheet Banner's WLC60 Heavy Duty Lights are engineered to withstand harsh environments, making it the first choice for a machine lighting solution. A conservative mechanical design protects against
More informationRosemount 1154 Alphaline Nuclear Pressure Transmitter
Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10
More informationSECTION 2: PROBES. Page 2-1
SECTION 2: PROBES RTDs and thermocouples in a variety of configurations for easy installation Tip-sensitive and fast response probes for quick and accurate temperature sensing High temperature probes to
More informationCATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.
CATALOG Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. APPLICATIONS Monitoring of the flow of concentrate and recirculation of a reverse osmosis water treatment plant Reverse Osmosis System Water
More informationCLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories
CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid
More informationAT9000 Advanced Transmitter Absolute Pressure Transmitters
No. SS2-GTX00A-0100 (Rev.8) AT9000 Advanced Transmitter Absolute Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and
More informationBushing diameter 16 mm, 19 mm or 22 mm. Easy to clean metal surface. Very long life expectancy. Ring or dot illumination. ➀ One-piece bushing
Piezo switches Specifications Bushing diameter 6 mm, 9 mm or 22 mm UG40--R3 Sealed to IP68 and IP69K (switches mounted on panel) Easy to clean metal surface Very long life expectancy Ring or dot illumination
More informationDiaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel
Ed.17.01 Design Diaphragm Seal with flush diaphragm and flange acc.to EN 1092-1 or ASME B 16,5 Pressure gauge in stainless steel Type Lower body Flush diaphragm with flange connection acc.to EN 1092-1
More information