4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT

Size: px
Start display at page:

Download "4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT"

Transcription

1 DHP MULTI-ZONE PRODUCT SPECIFICATIONS UP TO SEER UP TO DUCTLESS HEAT PUMP SYSTEMS UNITS FORM NO. DHPMULTI-00 (0/07) DHP MULTI-ZONE 8K / 0K / 6K / 8K Mid Efficiency (- SEER) Matches with all indoor units Variable Capacity Rotary Compressor DC Inverter Control Electronic Expansion Valve (EEV) Operates down to - F Up to Zones TON & UNDER TON S DWM WALL MOUNTED 9K / K / 8K / K Pre-Heat Fucntion LED Readout CEILING CASSETTE 9K / K / 8K / K Pre-Heat Fucntion Built-In Condensate Pump Grille Sold Seperately DUCTED UNIT 9K / K / 8K / K Medium Static Slim Ducts Built-In Condensate Pump Page

2 FEATURES AND BENEFITS UNITS Equipment Warranty: year parts, 7 year compressor SEER up to.00 HSPF up to 0 R0A Refrigerant Outdoor Coil: Aluminum fins fitted to copper tubes Refrigerant Line Connections, Service Valve Variable Frequency Rotarty Compressor Compressor Crankcase Heater DC Inverter Control Inverter Module Protection Outdoor Unit Microprocessor Electronic Expansion Valve Compressor Overcurrent Protection Condeser High Temperature Protection Voltage Protection Terminal Strip Defrost Control Reversing Valve Cabinet: Constructed of heavy gauge steel S - WALL-MOUNTED Pre-Heat Function LED Readout Auto Restart Cooling Override Flare Connections Multi-Refrigerant Outlet Three Speed Fan S - CASSETTE UNITS 60 Airflow Panel Pre-Heat Function LED Readout/Infared Receiver Panel Auto Restart Cooling Overide Built-In Condensate Pump Compact Design Flare Connections Four Speed Fan Turbo Fan with Backward Curved Blades Air Filter The cassette panel must be ordered seperatley. See Specifications table for ordering information. S - DUCTED UNITS Pre-Heat Function LED Readout Panel Auto Restart Cooling Overide Built-In Condensate Pump Dut Connections Flare Connections Three Speed Fan Air Filter NUMBER GUIDE MULTI-ZONE HEAT PUMP UNITS REFRIGERANT TYPE R0A SERIES TYPE D = DUCTLESS UNIT TYPE HP = HEAT PUMP MAJOR DESIGN SEQUENCE = ST GENERATION COOLING CAPACITY S = STANDARD EFFICIENCY WALL-MOUNTED S SERIES TYPE D = DUCTLESS SYSTEM UNIT TYPE WM = WALL MOUNT MAJOR DESIGN SEQUENCE = ST GENERATION NOMINAL COOLING CAPACITY 09 =.7 TONS = TONS 8 =. TONS = TONS 0 =. TONS CASSETTE S SERIES TYPE D = DUCTLESS SYSTEM UNIT TYPE C = X CASSETTE NON-DUCTED UNIT C = X CASSETTE NON-DUCTED UNIT MAJOR DESIGN SEQUENCE = ST GENERATION NOMINAL COOLING CAPACITY 09 =.7 TONS = TONS 8 =. TONS = TONS 0 =. TONS 8 = TONS D HP S 09 M - P D WM 09 S - P D C 09 S - P VOLTAGE P = 08/0- PHASE-60HZ MINOR DESIGN SEQUENCE = ST REVISION REFRIGERANT CIRCUITS S = SINGLE CIRCUITS M = MULTIPLE CIRCUITS NOMINAL COOLING CAPACITY 09 =.7 TONS 0 =. TONS = TONS 6 = TONS 8 =. TONS 8 = TONS = TONS VOLTAGE L = V- PHASE-60HZ P = 08/0- PHASE-60HZ MINOR DESIGN SEQUENCE = ST REVISION REFRIGERANT TYPE = R0A COOLING EFFICIENCY S = STANDARD EFFICIENCY VOLTAGE P = 08/0- PHASE-60HZ MINOR DESIGN SEQUENCE = ST REVISION REFRIGERANT TYPE = R0A COOLING EFFICIENCY S = STANDARD EFFICIENCY Page Page

3 SPECIFICATIONS - UNITS DUCTED S D MD S - P NUMBER DHPS8M-P DHPS0M-P DHPS6M-P DHPS8M-P NOMINAL SIZE- TONS.. SERIES TYPE D = DUCTLESS SYSTEM UNIT TYPE MD = MEDIDUM STATIC DUCTED MAJOR DESIGN SEQUENCE = ST GENERATION VOLTAGE P = 08/0- PHASE-60HZ MINOR DESIGN SEQUENCE = ST REVISION REFRIGERANT TYPE = R0A AHRI RATINGS NUMBER OF UP TO UP TO UP TO System Type Ducted Non-Ducted Ducted Non-Ducted Ducted Non-Ducted Ducted Non-Ducted Cooling - Btuh 8,000 8,000 7,000 8,000 6,000 6,000 8,000 8,000 Heating (7F) - Btuh 8,00 9,000 7,000 8,000 6,000 6,000 0,000 8,000 Heating (7F) - Btuh,00,000 6,00 7,00,800,000,000 9,600 Max Heating (F) - Btuh,00,900,000,900 8,00 8,000 6,800,900 SEER EER NOMINAL COOLING CAPACITY 09 =.7 TONS = TONS 8 =. TONS = TONS 0 =. TONS 8 = TONS COOLING EFFICIENCY S = STANDARD EFFICIENCY AMBIENT TEMP. RANGE HSPF (Region IV) HSPF (Region V) AHRI Reference Number TBD TBD TBD TBD TBD TBD TBD TBD Cooling Heating SOUND DATA db(a) Charge furnished (R-0A) 70. oz oz. 0.8 oz. 6. oz. REFRIGERANT Maximum line length with furnished charge (per zone) - ft. Additional charge required per ft. - oz Type Rotary Rotary Rotary Twin-Rotary COMPRESSOR Refrigerant oil type ESTER OIL VG7 ESTER OIL VG7 ESTER OIL VG7 ESTER OIL VG7 Refrigerant oil charge - oz CONNECTIONS - IN. MAX. HEIGHT DIFFERENCE BETWEEN INDOOR AND FAN Liquid+Gas pipe (flare) () / + () /8 () / + () /8 () / + () /8 + () / () / + () /8 + () / Max. Length for all rooms - ft Max. length for one indoor unit - ft Outdoor above indoor - ft. Outdoor below indoor - ft Max. difference in level bewteen indoor units (No.) Diameter - in. () - 8 () - () - () - 0 Total air volume - cfm 90 0,0 () 00 rpm () 800 Number of rows.6 Fins per inch COIL Fin type Hydrophilic Aluminum Hydrophilic Aluminum Tube outside diameter - in. /8 /8 /6 /6 Tube Type Rifled Copper Tubing Rifled Copper Tubing Net face area - sq. ft DESIGN PRESSURE PSIG 0/0 0/0 0/0 0/0 SHIPPING DATA Net/Shipping Weight (lbs.) 06 / 0 / 6 7 / 68 / ELECTRICAL DATA 08/0V 08/0V 08/0V 08/0V ELECTRICAL CHARACTERISTICS - 60 HZ - PHASE Maximum Overcurrent Protection (amps) 0 Minimum Circuit Ampacity 8 0 Compressor rated Load Amps 0 0 FAN MOTOR Rated Load Amps () 0.9 Input - W Page Page

4 SPECIFICATIONS - WALL MOUNTED S SPECIFICATIONS - MEDIUM STATIC DUCTED S NUMBER DWM09S-P DWMS-P DWM8S-P DWMS-P NOMINAL SIZE- TONS HZ - PHASE 08/0V ELECTRICAL CHARACTERISTICS RATED LOAD AMPS INPUT (W) 0 0 8(Output) 60(Output) COOLING 6-90 ROOM TEMP RANGE ( F) HEATING - 86 AIR VOLUME (CFM) HIGH/MED/LOW 70/68/96 7/7/98 0/0/9 69/6/8 SOUND DATA (DBA) HIGH/MED/LOW.7/./6../--/8.6 6./--/0.9.7/--/. LIQUID/ - O.D. - FLARE / / / / / / / / / /8 / /8 CONNECTIONS (IN.) DRAIN - O.D. WEIGHT (LBS.) NET/ PACKAGING 9.8/. 6.9/.8 9.9/.6 ELECTRICAL CHARACTERISTICS ROOM TEMP RANGE ( F) NUMBER DMD09S-P DMDS-P DMD8S-P DMDS-P NOMINAL SIZE- TONS HZ - PHASE 08/0V RATED LOAD AMPS 0.9. INPUT (W) COOLING 6-90 HEATING - 86 AIR VOLUME (CFM) HIGH/MED/LOW /90/0 70/0/60 0/0/60 80/60/0 SOUND DATA (DBA) HIGH/MED/LOW 8// /7/ /9/7 /8/ CONNECTIONS (IN.) LIQUID/ - O.D. - FLARE / / /8 / / / / / / /8 / /8 DRAIN - O.D. WEIGHT (LBS.) NET/ SHIPPING 0 / / / 6 8 / 69 SPECIFICATIONS - CASSETTE S ELECTRICAL CHARACTERISTICS ROOM TEMP RANGE ( F) NUMBER DC09S-P DCS-P DC8S-P DCS-P NOMINAL SIZE- TONS HZ - PHASE 08/0V RATED LOAD AMPS 0.9. INPUT (W) 8 COOLING 6-90 HEATING - 86 AIR VOLUME (CFM) HIGH/MED/LOW 7/0/7 79/09/6 60/8/ 700/66/7 SOUND DATA (DBA) HIGH/MED/LOW /7/ /9/6 /9/6 /7/ CONNECTIONS (IN.) LIQUID/ - O.D. - FLARE / / /8 / / / / / / /8 / /8 DRAIN - O.D. - / WEIGHT (LBS.) NET/ SHIPPING / 8 6 / 6 / 6 / ACCESSORY INFORMATION CASSETTE PANEL NET/ SHIPPING WEIGHT (LBS.) CATALOG # / 0 / 8 Page 6 Page 7

5 SYSTEM PERFORMANCE SYSTEM PERFORMANCE UNIT NUMBER # OF CAPACITY NOMINAL COOLING CAPACITY AT RATED SYSTEM CAPACITY (BTUH) NOMINAL HEATING CAPACITY AT RATED SYSTEM CAPACITY (BTUH) # # # # # # # # # # # # # # # UNIT NUMBER # OF CAPACITY NOMINAL COOLING CAPACITY AT RATED SYSTEM CAPACITY (BTUH) NOMINAL HEATING CAPACITY AT RATED SYSTEM CAPACITY (BTUH) # # # # # # # # # # # # # # # DHPS8M-P DHPS0M-P DHPS6M-P DHPS8M-P , , ,000 9, ,0 9, ,79 0, ,8 0, ,0 9, ,7 9, , , ,8 9, ,96 0, ,, ,6, ,80 7, ,, ,, ,60, ,7 7, ,79 0, ,90, , 8, ,9 8,9 8, ,66 0,66 0, , 9,, , 0,, ,68 0,68 0, ,60,8, ,6 7,6, ,97 8,97 6, ,7 9,7 9, ,99 0,99 0, ,788 7, ,0 9, ,87 0, ,86, ,0 6, ,9 8, ,00 7, ,0 8, ,900 8,900 8, ,76 9,76 9, ,6 8,6 0, ,97 8,97, ,8 8,8 7, ,0 9,0 8, ,8,7, ,0,679, ,0 0,09 6, ,7 0,7 7, ,60,7, ,66,6, ,68 0,68 0, ,886,886, ,90 9,90 6, ,0 0,0 6, ,99,898, ,7,97, ,000 9,000 9,000 9, ,000 9,000 9,000 9, ,7 9,7 9,7, - - 9,0 9,0 9,0, ,0 8,0 8,0 6, ,90 7,90 7,90 6, ,887 8,887 0,97 0, ,6 8,6 0,0 0, ,06 8,06 9,9 6, - - 7,8 7,8 9,68, ,809 0,8 0,8 0, ,8 0, 0, 0, , 0, 0, 0, - - 9,9 9,9 9,9 9, ,8, ,9, ,790 7, ,60 8, ,69, ,96, ,86 6, , 8, ,78, ,, ,9, ,8, DHPS8M-P ,9 9,9 9, ,680 9,680 9, ,06 9,06, ,6 9,6, ,9 8,9 7, ,0 9,0 8, ,8 8,8, , 9,, ,07,089, ,,80, ,00,66 7, ,,8 8, ,9,6, ,0,90, ,8 7,9 7, ,0 7,87 7, ,68 6,, ,0 6,67, ,,, ,0,, ,98,98, ,68,68, ,9,9 7, ,, 8, ,76 6,0 6, ,0 8,0 8, ,8,8, ,90,90, ,09 6,0, ,7 6,, ,900 0,768 -, ,0,760, ,0 6,0 6, ,70 7,70 7, ,8,8 0, ,86,86, ,09 9,09 9,09 9, ,9 9,9 9,9 9, ,97 8,97 8,97, ,70 9,70 9,70, ,88 8,88 8,88 6, ,8 9,8 9, 7, , 8, 8,, , 9, 9,0, ,9 8,9,678, ,60 9,60,80, ,86 8,86,66 6, ,0 9,0, 7, ,7 8,7 0,888, - - 9,0 9,0,0, ,9 8,9 6,8 6, ,7 9,7 6, 6, , 8,,9 0, - - 9,00 9,00,76, ,8,8,8, ,0,,, ,,6,6 6, ,8,00,00 7, , 0,0 0,0, ,0 9,0,6, ,98 0,6 6,7 6, ,,60 6,6 6, ,8,8,8,8 - -,0,0,0, ,697 0,697 0,697 6,6 - -,7,7,7 6, ,0 0,0 0,0 0, ,0,0,0 0, , 0,,77,77 - -,0,0 6, 6, ,000 9,000 9,000 9,000 9,000 9,800 9,800 9,800 9,800 9, ,8 8,8 8,8 8,8,79 9, 9, 9, 9,, ,67 8,67 8,67 8,67 6,7 9, 9, 9, 9, 6, ,9 8,9 8,9 8,9 9,0 9,09 9,09 9,09 9,09 9, ,687 8,687 8,687,079,079 9,0 9,0 9,,, ,86 8,86 8,86 0,89,98 9,0 9,0 9,0,0 6, ,0 8,0,87,87,87 9, 9,,870,870, ,7 8,7 0,8 0,8, 8,9 8,9 0,967 0,967, ,0 0, 0, 0, 0, 8,,,,, 0,06 0,06 0,06 0,06 0,06,0,0,0,0,0 Page 8 Page 9

6 CONNECTIONS AND LINE SET USAGE CONNECTIONS AND LINE SET USAGE NO. OF CAPACITY (UNIT NO.) LINE SET REQUIRED (LIQUID X ) NO. OF CAPACITY (UNIT NO.) LINE SET REQUIRED (LIQUID X ) NO. OF CAPACITY (UNIT NO.) LINE SET REQUIRED (LIQUID X ) NO. OF CAPACITY (UNIT NO.) LINE SET REQUIRED (LIQUID X ) 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (C) / in. x /8 in. DHPS8M A / LIQ + /8 B / LIQ + /8 DHPS0M A / LIQ + /8 B / LIQ + /8 C / LIQ + /8 DHPS6M A / LIQ + / B / LIQ + /8 C / LIQ + /8 D / LIQ + /8 009 (A) / in. x /8 in. / in. x /8 in. / in. x /8 in. 0 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (A) / in. x /8 in. / in. x /8 in. / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 08 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. / in. x /8 in. 08 (A) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. /8 x / in. gas pipe adaptor is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adaptor is required for line set connection to the 08 / x /8 in. gas pipe adaptor is required for line set connection to the 08 DHPS6M A / LIQ + / B / LIQ + /8 C / LIQ + /8 D / LIQ + /8 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (C) / in. x / in. 0 (B) / in. x / in. 08 (A) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. /8 x / in. gas pipe adaptor is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adaptor is required for line set connection to the 08 / x /8 in. gas pipe adaptor is required for line set connection to the 08 DHPS6M A / LIQ + / B / LIQ + /8 C / LIQ + /8 D / LIQ + /8 DHPS8M A / LIQ + / B / LIQ + / C / LIQ + /8 D / LIQ + /8 E / LIQ + /8 009 (D) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. / in. x /8 in. 0 (A), /8 in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 0 (B) / in. x / in. 0 (A), /8 in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 08 (B) / in. x / in. 0 (A), /8 in. x /8 in. 0 (A), /8 in. x /8 in. 0 (B), /8 in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. /8 x / in. gas pipe adaptor is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adaptor is required for line set connection to the 08 / x /8 in. gas pipe adaptor is required for line set connection to the 08 DHPS8M A / LIQ + / B / LIQ + / C / LIQ + /8 D / LIQ + /8 E / LIQ + /8 0 (B) / in. x / in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 009 (C) / in. x /8 in. 08 (B) / in. x / in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 0 (A), /8 in. x /8 in. 0 (B), /8 in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (A), /8 in. x /8 in. 0 (B) / in. x / in. 08 (C) / in. x / in. 0 (A), /8 in. x /8 in. 0 (C) / in. x / in. 0 (A), /8 in. x /8 in. 0 (B), /8 in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 08 (C) / in. x / in. 08 (B) / in. x / in. 08 (C) / in. x / in. 0 (A), /8 in. x /8 in. 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. /8 x / in. gas pipe adaptor is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adaptor is required for line set connection to the 08 / x /8 in. gas pipe adaptor is required for line set connection to the 08 Page 0 Page

7 CONNECTIONS AND LINE SET USAGE BLOWER DATA - MEDIUM STATIC DUCTED S DHPS8M A / LIQ + / B / LIQ + / C / LIQ + /8 D / LIQ + /8 E / LIQ + /8 NO. OF CAPACITY (UNIT NO.) LINE SET REQUIRED (LIQUID X ) / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (A) / in. x / in. 08 (B) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 08 (B) / in. x / in. 0 (A), /8 in. x /8 in. 009 (D) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 009 (D) / in. x /8 in. 0 (B) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 009 (D) / in. x /8 in. 0 (C) / in. x / in. 08 (A) / in. x / in. 08 (B) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 08 (A) / in. x / in. /8 x / in. gas pipe adaptor is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adaptor is required for line set connection to the 08 / x /8 in. gas pipe adaptor is required for line set connection to the 08 DHPS8M A / LIQ + / B / LIQ + / C / LIQ + /8 D / LIQ + /8 E / LIQ + /8 NO. OF CAPACITY (UNIT NO.) LINE SET REQUIRED (LIQUID X ) 009 (A) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 08 (A) / in. x / in. / in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A), /8 in. x /8 in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 009 (C) / in. x /8 in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (B) / in. x / in. 08 (A) / in. x / in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 009 (D) / in. x /8 in. 009 (E) / in. x /8 in. 0 (B) / in. x / in. 0 (C) / in. x / in. 08 (A) / in. x / in. 009 (E) / in. x /8 in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 0 (A) / in. x / in. 0 (B) / in. x / in. 0 (C) / in. x / in. 0 (D) / in. x / in. 0 (E) / in. x / in. /8 x / in. gas pipe adaptor is required for line set connection to outdoor unit (furnished with outdoor unit). / x /8 in. liquid pipe adaptor is required for line set connection to the 08 / x /8 in. gas pipe adaptor is required for line set connection to the 08 DMD8S-P Low Speed DMD8S-P Low Speed Medium Speed Medium Speed High Speed High Speed Page Page

8 BLOWER DATA - MEDIUM STATIC DUCTED S DIMENSIONS - UNITS - INCHES (MM) DMD0S-P Low Speed 0.0 Medium Speed 0.0 High Speed 0. DHPS8M MPA08SM / () (9) TOP VIEW -/ () -/8 () -/8 (9) /8 (69) -/8 (8) -/ (70) FRONT VIEW Page Page

9 DIMENSIONS - UNITS - INCHES (MM) DIMENSIONS - UNITS - INCHES (MM) DHPS0M, DHPS6M MPA00SM, MPA06SM DHPS8M MPA08SM 7-/ (96) -/8 (86) (6) -/ (6) -7/8 (78) -/8 (8) -7/8 (0) 7-/8 (8) -/ (9) -/8 (8) -7/8 7-/8 (0) (8) TOP VIEW TOP VIEW -7/8 (80) -7/8 (68) FRONT VIEW 7 (90) FRONT VIEW -/8 (79) Page 6 Page 7

10 DIMENSIONS - WALL-MOUNTED S - INCHES (MM) DIMENSIONS - WALL-MOUNTED S - WALL PLATES INCHES (MM) MWMA009S, MWMA0S, MWMA08S, MWMA0S, MWMA00S DWM09S, DWMS, DWM8S, DWMS, DWM0S -/ (0) MWMA009S and MWMA0S DWM09S, DWMS -/8 () Indoor unit outline TOP VIEW -/ () (79) -/ () B Left rear side refrigerant pipe inlet -/ (6) diameter -7/8 (8) -/8 () Right rear side refrigerant pipe inlet -/ (6) diameter C A 7/8 () MWMA08S DWM8S Indoor unit outline BOTTOM VIEW D -/8 () -/ () Left rear side refrigerant pipe inlet -/ (6) diameter 0-/ (60) 9 (99) -/ () Right rear side refrigerant pipe inlet -/ (6) diameter A B C D SIZE IN. MM IN. MM IN. MM IN. MM 009, 0-7/ / 7 7-7/ /8 -/ 88 8-/8 9 0, 00 6-/ 87 -/ -/ / 60 0-/8 (7) DWMS, MWMA0S DWM0S 0-7/8 (76) Indoor unit outline -/ () Left rear side refrigerant pipe inlet -/ (6) diameter 6-/ (87) 7/8 () -/ () Right rear side refrigerant pipe inlet -/ (6) diameter Page 8 Page 9

11 DIMENSIONS - CASSETTE S - INCHES (MM) DIMENSIONS - CASSETTE S - INCHES (MM) DCS, MA009S, DC6S, MA0S, DC8S MA08S DRAIN CONNECTION PIPE LIQUID PIPE FRESH AIR INTAKE -/ in. (6 mm) Diameter 0-/8 (6) DCS, DC6S, DC8S MA0S PIPE LIQUID PIPE FRESH AIR INTAKE in. (76 mm) Diameter 0-/ (78) -/8 (8) 8-/8 (06) 0-/8 () -/ (7) LEFT 6-/ (679) DRAIN CONNECTION RIGHT -/8 (8) BOTTOM VIEW (Body) LEFT -/ (6) -/ (7) RIGHT INSTALLATION HANGERS BOTTOM VIEW (Body) AIR OUTLET DIFFUSER PANEL AIR INLET AIR OUTLET LEVELING ADJUSTMENT NUT () CEILING AIR OUTLET DIFFUSER PANEL AIR INLET -/8 (600) (Ceiling Opening) AIR OUTLET 7-/8 (99) -/ (68) 7-/8 (99) BOTTOM VIEW (Panel) -/ (68) BOTTOM VIEW (Panel) Page 0 Page

12 DIMENSIONS - MEDIUM STATIC DUCTED S - INCHES (MM) LINE SET AND ELEVATION GUIDELINES MOUNTING LUGS () ELECTRICAL CONTROL BOX FRESH AIR INTAKE -/8 (9) Diameter (009 thru 08) (7) Diameter (0) MOUNTING LUGS () K () () -/8 () / (9) J TOP VIEW / (9) K Maximum Elevation - Indoor Units Above Outdoor Unit ft. (0 m) -/ (7) (6) E -/8 (67) SUPPLY AIR OPENING D A C FRONT VIEW B NOTE - Maximum Line Set Length Includes ALL piping in measurement Maximum Line Set Furthest Indoor Unit UNIT NOTE - Maximum Difference in Elevation Between Indoor Units - ft. (0 m). LIQUID PIPE PIPE Maximum Elevation - Indoor Units Below Outdoor Unit 9 ft. ( m) DRAIN CONNECTION OPTIONAL BOTTON RETURN AIR OPENING AIR FILTER H BOTTOM VIEW ELECTRICAL CONTROL BOX UNIT NO. DHPS08M- P DHPS00M- P DHPS06M- P DHPS08M- P MAXIMUM NUMBER OF S Two Three Four Five CONNECTIONS - LIQUID / () / / /8 () / / /8 () / / /8 ()/ / / () / / /8 () / / / RETURN AIR OPENING G TOTAL LENGTH OF ALL PIPING 98 ft. (0 m) 8 ft. ( m) 97 ft. (60 m) 6 (7 m) MAXIMUM LINE SET LENGTH - FURTHEST 66 ft. (0 m) 8 ft. ( m) 98 ft. (0 m) 98 ft. (0 m) F AIR FILTER REAR VIEW SIZE A B C D E IN. MM IN. MM IN. MM IN. MM IN. MM 009 thru 0 7-/ / 0 -/ / 9 -/ / 9 8-/ 0 9-/ / / 9 0-/ / SIZE F G H J K IN. MM IN. MM IN. MM IN. MM IN. MM 009 thru 0 -/ /8 00 -/ /8 70 -/ /8 00 -/ / 99 -/ / 60 / 9 7-/ 99 -/ 9 Page Page

13 ACCESSORIES (FURNISHED) WIRELESS REMOTE CONTROL OPERATION WIRELESS REMOTE CONTROL Furnished with Wall-Mounted Indoor Units, Cassette Indoor Units and Ceiling/Floor Indoor Units. NOTE - Can be ordered separately for ducted indoor units. Complete remote control of system. Maximum operating range is ft. Operates on two AAA.V batteries (furnished). Wireless remote control holder furnished. Holder can be mounted on a wall for easy access. Mounting screws furnished.. ON/OFF Button 6 Turns system on and off.. MODE Button ON/OFF MODE FAN TURBO SLEEP SELF CLEAN TEMP SILENCE FP TIMER ON TIMER OFF SWING DIRECT LED FOLLOW ME Select system operation modes. Push button to cycle through each setting TURBO Button Enables the unit to reach the preset temperature during cooling or heating operation in the shortest time. 6. SELF CLEAN Button Automatically cleans and dries the evaporator coil at the end of the cooling season, preventing any odors or mildew. 7. UP/DOWN Buttons Increase or decrease the indoor temperature in one degree increments (maximum 86 F, minimum 6 F). NOTE - Temperature cannot be adjusted in FAN mode. NOTE - Press and hold and buttons together for seconds to alternate the temperature display between the C and F scale. 8. SILENCE/FP Button Silence - Operates the compressor at low frequency and low fan speed to reduce operating sound levels to a minimum. FP - Only available during heating operation. Unit will operate at a set temperature of 6 F. NOTE - To cancel, push the ON/OFF, SLEEP, FP, MODE, FAN SPEED, UP/DOWN buttons. 9. TIMER ON / TIMER OFF Buttons TIMER ON (initiates an auto-on time sequence) and TIMER OFF (initiates an auto-off time sequence) can be used separately or together. Each press of the button increases the time in 0 minute increments up to 0 hours. Above 0 hours each press of the button will increase the auto-timed setting by 60 minutes up to hours. NOTE - To cancel, set timer to 0.0 or turn remote off and on. 0. SWING Button Used to stop or start horizontal louver auto swing feature. Mode display AUTO HEAT COOL FAN Fan speed indication DRY Displayed when data transmitted. Displayed when remote controller ison. Battery display (low battery detection) Displayed when TIMER ON time is set. Displayed when TIMER OFF time is set. Show set temperature or room temperature, or time undertimer setting. Displayed insleep Mode operation. Indicated that the air conditioner is operating infollow memode Low speed Medium speed High speed Auto fan speed AUTO OPERATION. Press the MODE button to select Auto.. Press the UP/DOWN button to set the desired temperature. The temperature can be set within a range of. Press the ON/OFF button to start the air conditioner. COOLING /HEATING/FAN OPERATION. Press the MODE button to select COOL, HEAT or FAN mode.. Press the UP/DOWN buttons to set the desired temperature.. Press the FAN button to select the fan speed in four steps- Auto, Low, Med,or High.. Press the ON/OFF button to start the air conditioner. DEHUMIDIFYING OPERATION. Press the MODE button to select DRY mode.. Press the UP/DOWN buttons to set the desired temperature.. Press the ON/OFF button to start the air conditioner. TIMER ON/OFF OPERATION. Press the TIMER ON or TIMER OFF button. The remote controller shows TIMER ON or TIMER OFF icon, the previous Auto-on time setting and the signal H will be shown on the LCD display area.. Push the TIMER ON or TIMER OFF button again to set desired time. Each time you press the button, the time increases by 0 minutes between 0 and 0 hours and by 60 minutes between 0 and hours.. After setting the TIMER ON or TIMER OFF there will be a one second delay before the remote control transmits the signal to the unit. After approximately seconds, the signal H will disappear and the set temperature will re-appear on the LCD display window. AUTO COOL DRY HEAT FAN. FAN Button Select fan speed. Push button to cycle through each setting. AUTO LOW MED HIGH NOTE - Not available in AUTO or DRY modes.. DIRECT Button Used to change the louver movement and set the desired up/down air flow direction. The louver angle changes 6 for each press of the button.. FOLLOW ME Button Allows remote temperature sensing of the room at the remote control location. Note - During unit operation only the active functions will be shown on the display.. SLEEP Button Enables the system to automatically increase cooling or decrease heating (in F increments) per hour for the first hours, then maintain a steady temperature for hours. NOTE - To cancel, push the MODE, FAN SPEED or ON/OFF buttons. NOTE - SLEEP mode is only available when the unit is in COOL, HEAT or AUTO mode.. LED Button Turns the LCD display backlight on the indoor unit on or off. Page Page

14 WIRED REMOTE CONTROL Furnished with Ducted Indoor Units. NOTE - Can be ordered separately for non-ducted indoor units. FEATURES Backlight - Allows easy operation in a dark room. The controller lights when any button is pressed and remains lit during control access. Permanent Memory - Maintains clock, fan speed and mode of operation settings following power outages. Dimensions (H x W x D) - -/ x -/ x 7/8 in. Additional hardware is furnished for installation. Wiring - Controller uses -wire shielded cable (not furnished) for easy low voltage connection to the indoor unit. DISPLAY TIME (ON/OFF) MODE DISPLAY BUTTONS AND FUNCTIONS MODE SELECTION TIMERON TIMER OFF FOLLOWME RESET MODE Button TIMER ON TIMER OFF FOLLOW ME RESET MODE LOCK LOCK INDICATOR TEMPERATURE DISPLAY FANSPEED ECO SWING TEMP FOLLOW ME INDICATOR ON/OFF INDICATOR FAN SPEED INDICATOR POWER ADJUSTMENT UP ADJUSTMENT DOWN SWING ECONOMY FAN SPEED SELECTION LOCK Select system operation modes. Push button to cycle through each setting. AUTO COOL DRY HEAT FAN POWER Button Turns system on and off. FAN SPEED Button Selects fan speed. Each button press cycles through the following settings on display. NOTE - Not available in AUTO mode. TIMER ON / TIMER OFF Buttons TIMER ON (initiates an auto-on time sequence) and TIMER OFF (initiates an auto-off time sequence) can be used separately or together. Each press of the button increases the time in 0 minute increments up to 0 hours. Above 0 hours each press of the button will increase the auto-timed setting by 60 minutes up to hours. NOTE - To cancel, set timer to 0.0. UP/DOWN Buttons Increase or decrease the indoor temperature in two degree increments (maximum 88 F, minimum 6 F). NOTE - Temperature cannot be adjusted in FAN mode. NOTE - Press and hold and buttons together for seconds to alternate the temperature display between the C and F scale. SWING Button Used to stop or start horizontal louver auto swing feature. ECONOMY Button Maintains the most comfortable temperature and saves energy. RESET Button (Recessed) Resets Controller to factory settings. Recessed to prevent tampering. LOCK Button (Recessed) Locks Controller buttons to prevent tampering with settings. OPTIONAL ACCESSORIES - ORDER SEPERATLEY DESCRIPTION CATALOG # UNIT CONDENSER PAD (8 X 6 X ) Y0 x x x x DISCONNECTS FUSES LINE SETS WALL BRACKETS WHIPS CONDENSATE PUMP 0 AMP, FUSED, PH 7P7 x x x x 60 AMP, NON-FUSED, PH 7P9 x x x x 0A 8P7 x x x x 60A 8P77 x x x x / X /8 X 90X / X /8 X 0 X08 / X / X 90X x / X / X 0 X09 x /8 X /8 X X806 x x x /8 X /8 X 0 X807 x x x 0 Y00 x 6 Y0 x x x 0 GAUGE - / X 6 9P x x x x 8 GAUGE - / X 6 7P x x x x 7.9 US GALLONS/HR. FT. LIFT - 0/0V CONTROLS Y70 x x x x WIRELESS REMOTE CONTROL.8606 x x x x INDOOR/ WIRING CABLE WIRED REMOTE CONTROL.8607 x x x x GAUGE, CONDUCTOR WIRE, THHN, 0 FT. Y067 x x x x NOTE- CONTROLS ARE FURNISHED WITH S. WIRED WITH DUCTED, WIRELESS WITH ALL OTHERS. THESE ACCESSORIES ARE ALTERNATIVES FOR THOSE OPTIONS- I.E. WIRELESS WITH DUCTED OR WIRED WITH ALL OTHERS. LINESET COVER STARTER KIT Y87 x x x x LINESET COVER X 6. Y88 x x x x UNION COUPLING Y89 x x x x 90 DEGREE FLAT BEND ELBOW Y90 x x x x 90 DEGREE INSIDE ELBOW Y9 x x x x DEGREE FLAT BEND ELBOW Y9 x x x x FLEX JOINT Y9 x x x x T-JOINT Y9 x x x x DUCT END Y9 x x x x FALT WALL ESCUTCHEON Y96 x x x x WALL PENETRATION COVER Y99 x x x x MOUNT BLOCK (WHITE) QTY () - Y97 x x x x MOUNT BLOCK (WHITE) QTY () - 6 Y98 x x x x Page 6 Page 7

15 VARIABLE CAPACITY HEAT PUMP SHP0LX All specifications and illustrations subject to change without notice and without incurring obligations. FORM NO. DHPMULTI-00 (0/07) 07 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A. Page 8

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18.

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18. ENVIRONMENTALLY SOUND REFRIGERANT H4A3 Product Specifications EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 3 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 3 phase, 60 Hz

More information

MV Product Specifications

MV Product Specifications MODULAR VARIABLE SPEED BLOWER CABINET 2, 3, 4, and 5 TONS FEATURES Variable Speed modular blower Supports two-stage outdoor units Dehumidification Speed: 80% Airflow Efficient low continuous fan selection:

More information

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units. Product Catalog Variable Refrigerant Flow (VRF) System Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH/4TVR0072 0192 4TVH/4TVR0216 0528 Single Unit Modules Multi-Unit Modules January 2016 VRF-PRC008C-EN

More information

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000

More information

Product Specifications

Product Specifications Product Specifications MODULAR ELECTRIC FURNACE 2, 3,4,and5TONS FEATURES S Modular Blower Cabinet, Air Conditioning or Heat Pump ready S Upflow, horizontal right or left applications S Downflow requires

More information

Product Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN.

Product Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN. Product Catalog Variable Refrigerant Flow (VRF) ir Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* February 2015 VRF-PRC008B-EN Introduction Copyright Trane VRF variable refrigerant systems

More information

AIR CONDTIONERS XC16. ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology

AIR CONDTIONERS XC16. ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology AIR CONDTIONERS XC16 ELITE Series R-410A - Two-Stage Compressor - SilentComfort Technology E N G I N E E R I N G D ATA Bulletin 210465 October 2009 Supersedes March 2009 SEER up to 17.20 2 to 5 Tons Cooling

More information

BLOWER COILS. 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES EBP MODEL FEATURES EBX/EBXXMODELFEATURES

BLOWER COILS. 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES EBP MODEL FEATURES EBX/EBXXMODELFEATURES BLOWER COILS 1½ THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Grooved copper tubing Lanced sine--wave aluminum fin Fully wettable

More information

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H)

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) DFF4(A/H) - indoor and DFC4(A/H) -outdoor DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

Daikin AURORA MULTI-ZONE HEATING & COOLING SYSTEMS

Daikin AURORA MULTI-ZONE HEATING & COOLING SYSTEMS Daikin AURORA MULTI-ZONE HEATING & COOLING SYSTEMS 1.5 & 2 TON, 2 & 3 ZONE SYSTEMS Up to 17.9 SEER / 12.5 HSPF / 12.7 EER INVERTER, VARIABLE SPEED COMPRESSOR Flexible options providing high efficiency

More information

VRF 50/60Hz V5 E Series

VRF 50/60Hz V5 E Series 1702-1V1701 VRF 50/60Hz V5 E Series Coercial Air Conditioners 2017/2018 VRF 50/60Hz V5 E Series Coercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde,

More information

BLOWER COILS COMMERCIAL

BLOWER COILS COMMERCIAL BLOWER COILS COMMERCIAL 2 THRU 5 TONS SPLIT SYSTEM EBP / EBX / EBXX Series FEATURES Representative photo only, some models may vary in appearance. Listed By Underwriters Laboratories Grooved copper tubing

More information

2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment

2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment ANSI/AHRI Standard 1230 with Addendum 2 2010 Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment Approved by ANSI on 2 August 2010 ANSI/AHRI

More information

Cabinet Features Heavy-gauge, galvanizedsteel. powder-paint finish Full perimeter rail Sloped drain pan Easy to service

Cabinet Features Heavy-gauge, galvanizedsteel. powder-paint finish Full perimeter rail Sloped drain pan Easy to service DG ommercial 7½- TO ½-TON THREE-PHASE PAKAGED GAS/ ELETRI UP TO. EER / 80% AUE ooling apacity: 88,000,000 BTU/h Heating apacity (Output): 68,000 BTU/h ontents Nomenclature... Product Specifications...

More information

Installation Instructions

Installation Instructions Installation Instructions AquaSnap 010-055 Chilled Water Storage Tank 50/60 Hz Part No: -900---001; -900---009; -900---010 CONTENTS INTRODUCTION.................................. 1 SAFETY CONSIDERATIONS......................

More information

B. System Design and Performance Requirements

B. System Design and Performance Requirements 15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes

More information

Product Data. (Unit shown with optional economizer.)

Product Data. (Unit shown with optional economizer.) COOLING ONLY/ELECTRIC HEAT PACKAGED ROOFTOP UNIT 15 TO 27.5 NOMINAL TONS Product Data (Unit shown with optional economizer.) C09316 Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

Product Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs)

Product Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs) 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons Product Data Carrier s air-cooled air conditioning split systems: S provide a logical solution for commercial needs S have

More information

Product Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS

Product Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS Z / D 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons Product Data FEATURES / BENEFITS Z07-14 shown C09227 the environmentally sound refrigerant Carrier s air-cooled air

More information

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw YKN2open Features High efficiency EER and COP Low noise level All configurations: Cooling only, Cooling + gas, Heating, Heating +

More information

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM YORK UNITIZED ENERGY RECOVERY VENTILATORS Regardless of building type or rating system, today s building must be as energy

More information

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump MIRAI SMI Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump Air conditioning Technical sheet 20C GB02 Indice Monobloc heat pump

More information

Zoned Comfort Control

Zoned Comfort Control Product Guide Zoned Comfort Control The complete line-up of whole-home residential zoning products; designed for simpler installation, durable operation and more profitable jobs. YOUR PARTNERS IN COMFORT

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

OIL-INJECTED ROTARY SCREW COMPRESSORS. G ( kw / hp) / G VSD ( kw / hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. G ( kw / hp) / G VSD ( kw / hp) OIL-INJECTED ROTARY SCREW COMPRESSORS G -250 (-250 kw / -30 hp) / G - VSD (- kw / - hp) RELIABLE TECHNOLOGY IN A ROBUST DESIGN Atlas Copco has a long, and successful history of designing and building rugged

More information

Energy Savers: Air-Source Heat Pumps

Energy Savers: Air-Source Heat Pumps 1 of 5 4/25/2009 8:55 AM U.S. Department of Energy - Energy Efficiency and Renewable Energy Energy Savers Air-Source Heat Pumps An air-source heat pump can provide efficient heating and cooling for your

More information

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer. Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09262 the environmentally sound refrigerant This product has been designed and manufactured

More information

Product Specifications

Product Specifications Product Specifications Models Unit Cooling Capacity kw 0.30~2.63~3.80 0.30~3.51~4.04 Btu/h. 1,023~9,000~12,966 1,023~12,000~13,785 Heating Capacity kw 0.30~3.22~6.50 0.30~3.98~6.50 Btu/h. 1,023~11,000~20,472

More information

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models :

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models : ROOM AIR CONDITIONER AK SERIES (50Hz) Models : AKY9FBSSW AKY9UBSSW CONTENTS SPECIFICATIONS.......................... CIRCUIT DIAGRAM........................ MICROCOMPUTER CONTROL CIRCUIT...... DISASSEMBLY

More information

Air Cooled Packaged Air Conditioning

Air Cooled Packaged Air Conditioning Cooling Capacity 11.6kW - 193.0kW Heating Capacity 10.8kW - 213.0kW eco series Packaged Air Conditioning Giving you complete control More than just another air conditioning company. temperzone is dedicated

More information

Series Sump and Sewage Systems

Series Sump and Sewage Systems Series 000 Sump and Sewage Systems file no: 0. date: may 17, 13 supersedes: 0. date: march 29, 13 Series 000 Sump Series 0 & 2 Armstrong offers a complete range of high performance, easily maintained Column

More information

Large University Central Chiller Plant Design Considerations

Large University Central Chiller Plant Design Considerations Carrier Engineering Newsletter Volume 5, Issue 3 Large University Central Chiller Plant Design Considerations Large campus chilled water plants have unique constraints and need careful evaluation for successful

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS SECTION 23 74 13 PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

DVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons

DVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons DVPTC Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons Contents Air Handler Nomenclature...2 Heater Kit Nomenclature...2 Product Specifications...3

More information

50KC Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613

50KC Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons. Product Data C08613 Cooling Only/Electric Heat Packaged Rooftop 14 SEER 3to5NominalTons Product Data C08613 TABLE OF CONTENTS PAGE FEATURES AND BENEFITS... 3 MODEL NUMBER NOMENCLATURE... 4 FACTORY OPTIONS & ACCESSORIES...

More information

VPL-3200B Residential Vertical Platform Lift Technical Specifications

VPL-3200B Residential Vertical Platform Lift Technical Specifications Page 1 of 5 VPL-3200B Residential Vertical Platform Lift Technical Specifications MODEL NUMBER: VPL-3200B Series: Models VPL-3210B, VPL-3212B and VPL-3214B (DC-powered units) U.S. F.D.A. CLASSIFICATION:

More information

trusted innovative expertise

trusted innovative expertise Ingersoll Rand is well into its second century of building our legacy as a trusted global leader by delivering the innovative solutions and expertise our customers require. We continue to advance compressed

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 0 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS MPA, MPB and MLA MULTI-ZONE OUTDOOR UNITS MULTI-ZONE MINI-SPLIT OUTDOOR UNITS (08/0V) -- 079-0 0/0 Supersedes 079-0 Table of Contents

More information

Gerber M Series Site Requirements

Gerber M Series Site Requirements Gerber M Series Site Requirements Preparing for the arrival of your new machine. P rior to the arrival of your Gerber M Series Cutting System there are certain things you can prepare to facilitate a quick

More information

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.) C09248

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.) C09248 Gas Heat/Electric Cooling Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09248 the environmentally sound refrigerant This product has been designed and manufactured

More information

HOBO Plug Load Logger (UX ) Manual

HOBO Plug Load Logger (UX ) Manual HOBO Plug Load Logger (UX120-018) Manual The HOBO Plug Load logger is designed to monitor energy consumption of AC-powered plug in loads. This compact device can be used as a power meter with its built-in

More information

CI/SfB (57.7) 1st edition

CI/SfB (57.7) 1st edition CI/SfB (57.7) 1st edition Vent-Axia Sentinel Multivent Wholehouse Mechanical Extract Ventilation System Ventilation Lo-Carbon Energy saving solutions Sentinel Multivent continuous mechanical extract ventilation,

More information

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies.

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies. Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs Valent is a business of Unison Comfort Technologies. When your HVAC system design calls for high-percentage or 100%

More information

Using the PPM2 Portable Trace Moisture Transmitter

Using the PPM2 Portable Trace Moisture Transmitter APPLICATION NOTE 2016_0106 PPM2 Using the PPM2 Portable Transmitter The Model PPM2 Portable analyzer is a compact, cost effective, analyzer specifically designed to continuously measure low levels of moisture

More information

ACBC Floor Mounted Active Beam

ACBC Floor Mounted Active Beam Floor Mounted Active Beam The Price Floor Mounted Active Beam,, is designed for occupant comfort. It provides high cooling and heating capacities while simultaneously supplying ventilation air from a DOAS

More information

RDI Systems. Scroll Series Refrigeration System. Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models

RDI Systems. Scroll Series Refrigeration System. Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models RDI Systems Scroll Series Refrigeration System Air Cooled Indoor/Outdoor Scroll Condensing Units 3/4 thru 6 Hp Models PC Refrigeration Systems The RDI PC Refrigeration system includes an RDI condensing

More information

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2016 An Integrated Solution for Commercial AC Chillers Using Variable Speed

More information

Air Conditioners. Technical Data. Pair application EEDEN RXS-J

Air Conditioners. Technical Data. Pair application EEDEN RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J Air Conditioners Technical Data Pair application EEDEN11-100 RXS-J TABLE OF CONTENTS RXS-J 1 Features.............................................................

More information

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with optional economizer.

Product Data. 48TC Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons. (Unit shown with optional economizer. Gas Heat/Electric Cooling Packaged Rooftop 15 to 27.5 Nominal Tons Product Data (Unit shown with optional economizer.) C09248 Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

Lubricated Rotary Screw Air Compressors. Constant Speed Drives and Variable Speed Drives kw hp

Lubricated Rotary Screw Air Compressors. Constant Speed Drives and Variable Speed Drives kw hp Lubricated Rotary Screw Air Compressors Constant Speed Drives and Variable Speed Drives 18 30 kw 25 40 hp About Sullair For more than 50 years, Sullair has been on the leading edge of compressed air solutions.

More information

Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics

Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics Trane believes the facts and suggestions presented here to be accurate. However, final design and application

More information

SECTION ROTARY SCREW WATER CHILLERS

SECTION ROTARY SCREW WATER CHILLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SUPERSTEAM USG LINE UNFIRED STEAM GENERATOR. Humidification. Sterilization. Pharmaceutical

SUPERSTEAM USG LINE UNFIRED STEAM GENERATOR. Humidification. Sterilization. Pharmaceutical SUPERSTEAM USG LINE UNFIRED STEAM GENERATOR. Humidification. Sterilization. Pharmaceutical Basic USG Package Includes: ASME Code Constructed and National Board Registered Vessel Fiberglass Insulation 20

More information

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

1. Vertical reciprocating conveyor, Hydraulic straddle VRC. PART 1: GENERAL 1.01 Section Includes: 1. Vertical reciprocating conveyor, Hydraulic straddle VRC. a. Machine, controller, platform, structural steel hoist frame. b. Wire mesh enclosure and gates. Related

More information

SECTION HVAC INSTRUMENTATION AND CONTROLS INSTALLATION. (Applicable to IUPUI Only)

SECTION HVAC INSTRUMENTATION AND CONTROLS INSTALLATION. (Applicable to IUPUI Only) SECTION 15957 (Applicable to IUPUI Only) I. GENERAL A. NOTES 1. The University has a pre-purchase agreement (PPA) with Johnson Controls (JCI) and Siemens Building Technologies (SBT). The University will

More information

WATER-COOLED HELICAL ROTARY CHILLER

WATER-COOLED HELICAL ROTARY CHILLER WATER-COOLED HELICAL ROTARY CHILLER 1.0 GENERAL REQUIREMENTS 1.1 Application. This technical specification applies to equipment and materials furnished and installation work performed by the Contractor.

More information

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY) PART 1 GENERAL 1.1 SCOPE 1.1.1 The manufacturer shall furnish a low profile, multi-tray Air Stripper for removal of volatile organic

More information

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES... DIVISION 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN Contents 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION 13 00 60 LIST OF FIGURES... 6 13 00 60 - MEDIUM VOLTAGE VAULT DESIGN 1. General Requirements

More information

Cool Smart Incremental Cost Study: Final Report

Cool Smart Incremental Cost Study: Final Report Cool Smart Cost Study: Final Report July 2015 Prepared for: The Electric and Gas Program Administrators of Massachusetts Part of the Residential Evaluation Program Area This page left blank. Prepared by:

More information

01 Introduction TARGET. Multi Domestic. Commercial. 50, High Efficiency - High Efficiency Operation - Hot water with free of charge (HR)

01 Introduction TARGET. Multi Domestic. Commercial. 50, High Efficiency - High Efficiency Operation - Hot water with free of charge (HR) 01 Introduction TARGET POSITION FEATRE Multi Domestic EHS Mono/Split Low Temperature - Domestic, 50 water EHS High Temperature - Domestic, 80 water All-in-One More Efficient Free of Charge 50 or 80 Water

More information

SECTION AUTOMATIC TRANSFER SWITCH

SECTION AUTOMATIC TRANSFER SWITCH SECTION 26 36 23 AUTOMATIC TRANSFER SWITCH PART 1: GENERAL 1.01 SCOPE A. Furnish all labor, materials, equipment and appurtenances, install and test electrically operated, automatic transfer switch (ATS)

More information

l a t i t u d s e r i e s A I R C O N D I T I O N E R S & H E A T P U M P S

l a t i t u d s e r i e s A I R C O N D I T I O N E R S & H E A T P U M P S l a t i t u d e s e r i e s A I R C O N D I T I O N E R S & H E A T P U M P S Life is always better when you have choices. That s what makes your home so unique and cozy. That s also why millions of families

More information

I S O. Eco-Smart Energy Recovery Ventilator

I S O. Eco-Smart Energy Recovery Ventilator I S O I S O 9 0 0 1 1 4 0 0 1 Eco-Smart Energy Recovery Ventilator What s Eco-Smart? Holtop has manufactured heat and energy recovery ventilation products for over 12 years. We pay high attentions on the

More information

INDOOR UNITS FVXS25F FVXS35F FVXS50 F

INDOOR UNITS FVXS25F FVXS35F FVXS50 F Cooling Only INDOOR UNITS FVXS25F FVXS35F FVXS50 F Capacity cooling min~nom~max kw 1.3~2.5~3.0 1.4~3.5~3.8 1.4~5.0~5.6 Power input cooling min~nom~max kw 0.300~0.570~0.920 0.300~1.020~1.250 0.310~1.220~1.880

More information

TYP. SINGLE PLY ROOFING ROOF SHEETING BROAN VENT CAP #10 x 1" GASKETED SMS TYP. 4 SIDES 8" FRAMED CURB HVAC SYSTEMS "BASIS OF DESIGN" ROOF INSULATION R-19 WALL INSULATION R-13 LIGHTING EFFIECNCY PER STANDARDS

More information

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP Service Manual Imperial Series Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP Contents of Service Manual 1. Safety Precautions ------------------------------------------------------------------

More information

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720) CTD Proposal : - Project: Project Location: Cooling Tower Design Conditions and Dimensions: Water Flow Rate (gpm) 0 CTD Model # Hot Water Temp (F) 0 Cell Dimensions (ft) L x W x H Cold Water Temp (F) 0

More information

PT Mount. Multi-purpose Application & Economical. Multi-purpose Application at Low Cost. Round Type Vibration-proof Rubber. Example for Installation

PT Mount. Multi-purpose Application & Economical. Multi-purpose Application at Low Cost. Round Type Vibration-proof Rubber. Example for Installation Round Type Vibration-proof Rubber PT Mount Multi-purpose Application & Economical Wide Load Range Multi-purpose Application at Low Cost Respond widely, if Summarize power A, B, C, Company TOZEN Reasonable!

More information

VARIABLE REFRIGERANT FLOW MULTI-SPLIT AIR-CONDITIONERS AND HEAT PUMPS CERTIFICATION PROGRAM

VARIABLE REFRIGERANT FLOW MULTI-SPLIT AIR-CONDITIONERS AND HEAT PUMPS CERTIFICATION PROGRAM VARIABLE REFRIGERANT FLOW MULTI-SPLIT AIR-CONDITIONERS AND HEAT PUMPS CERTIFICATION PROGRAM VRF OM JANUARY 2018 2111 Wilson Boulevard, Suite 500 Arlington, Virginia 22201 (703) 524-8800 Sponsored and administered

More information

Series V Cooling Tower

Series V Cooling Tower Series V Cooling Tower T A B L E O F C O N T E N T S B95 B97 B99 SERIES V COOLING TOWER BENEFITS CONSTRUCTION DETAILS B101 CUSTOM FEATURES & OPTIONS B109 ENGINEERING DATA B117 STRUCTURAL SUPPORT P R O

More information

AS950 ALL-WEATHER REFRIGERATED SAMPLER

AS950 ALL-WEATHER REFRIGERATED SAMPLER AS950 ALL-WEATHER REFRIGERATED SAMPLER Applications Wastewater Collection systems Industrial pretreatment Environmental monitoring Stormwater Sampling has never been this easy. Hach's AS950 sampler controller

More information

120 Series Refrigeration Systems

120 Series Refrigeration Systems 120 Series Refrigeration Systems RDI Systems Air Cooled Indoor/Outdoor Condensing Units Hermetic / Scroll / Semi-Hermetic ½ thru 6 Hp s PC Refrigeration Systems The RDI PC Refrigeration system includes

More information

Available from IPP: 3.2MW Cogeneration Plant. (4x 800KW Reciprocating Natural Gas Generators)

Available from IPP: 3.2MW Cogeneration Plant. (4x 800KW Reciprocating Natural Gas Generators) Available from IPP: 3.2MW Cogeneration Plant (4x 800KW Reciprocating Natural Gas Generators) IPP Plant Dept. Stock No. 600658, Equipment Stock No s 216310 216324 Prepared By: Ross Gale 1 About the Plant:

More information

SECTION LUMINAIRES AND ACCESSORIES

SECTION LUMINAIRES AND ACCESSORIES SECTION 16500 LUMINAIRES AND ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to

More information

B. Shop Drawings: For air terminal units. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For air terminal units. Include plans, elevations, sections, details, and attachments to other work. SECTION 233600 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fan-powered air terminal units. 2. Shutoff, single-duct air terminal units. 1.2 PERFORMANCE REQUIREMENTS A. Structural Performance:

More information

ingersoll rand air compressors rseries compressors

ingersoll rand air compressors rseries compressors Distributors For: Branch Directory: 149 Glasgow Road Wishaw Lanarkshire ML2 7QJ Tel 01698 355711 Fax 01698 359299 Wellheads Road Farburn Industrial Estate Dyce, Aberdeen AB21 7HG Tel 01224 723434 Fax 01224

More information

Attachment 1: RAE Corporation Technical Specification

Attachment 1: RAE Corporation Technical Specification Attachment 1: RAE Corporation Technical Specification RAE Corporation Phone: 918-825-7222, ext. 105 Steve Corbin Quote# XXXX Qty Customer Tag Technical Systems Model Number 1 ACC-4 10A0-162-S General Scope

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

5.2 MW Solar Mobile Power Unit

5.2 MW Solar Mobile Power Unit 5.2 MW Solar Mobile Power Unit Ventilation air intake Ventilation air exhaust Air inlet & silencer Exhaust Silencer Power Control Room & Trailer -13.8 KV switchgear -CO2 fire system -480 VAC MCCC for turbine

More information

Guide Specifications. Landmark Rooftop Units. Packaged Outdoor HVAC Equipment. May 18, 2017

Guide Specifications. Landmark Rooftop Units. Packaged Outdoor HVAC Equipment. May 18, 2017 Packaged Outdoor HVAC Equipment Guide Specifications Landmark Rooftop Units May 18, 2017 Note: This specification specifies Lennox Industries Landmark Rooftop Units. Revise specification section number

More information

Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostatic expansion valves, type T 2 and TE 2 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

MUZ-GE09NAH MUZ-GE09NAH2 MUZ-GE12NAH MUZ-GE12NAH2 MUZ-GE15NAH MUZ-GE15NAH2 MUZ-GE18NAH MUY-GE18NA, - 1 MUY-GE24NA

MUZ-GE09NAH MUZ-GE09NAH2 MUZ-GE12NAH MUZ-GE12NAH2 MUZ-GE15NAH MUZ-GE15NAH2 MUZ-GE18NAH MUY-GE18NA, - 1 MUY-GE24NA SPLIT-TYPE AIR CONDITIONERS Revision F: MUZ-GE//5, MUZ-GE//5NAH and MUY-GE//5 have been added. Please void OBB549 REVISED EDITION-E. OUTDOOR UNIT PARTS CATALOG No. OBB549 REVISED EDITION-F Models MUZ-GENA

More information

Mechanical Product Overview

Mechanical Product Overview Mechanical Product Overview The founding principles of Price have never changed business integrity, first class service, innovation and a commitment to people. PURPOSE BUILT FOR YOUR APPLICATION Whether

More information

PARTS LIST. Marine/Industrial Single Package Cooling Unit 90MA/MF/MU. Design Series One, Beginning Serial Number C96741 & Design Series Two

PARTS LIST. Marine/Industrial Single Package Cooling Unit 90MA/MF/MU. Design Series One, Beginning Serial Number C96741 & Design Series Two Marine/Industrial Single Package Design Series One, Beginning Serial Number C96741 & Design Series Two 62-10404 -01 PARTS LIST Service Parts List SINGLE PACKAGE COOLING UNIT Design Series One, Beginning

More information

ASHRAE Chapter Meeting HVAC Noise & Vibration Control Specifications & Best Practices

ASHRAE Chapter Meeting HVAC Noise & Vibration Control Specifications & Best Practices ASHRAE Chapter Meeting HVAC Noise & Vibration Control Specifications & Best Practices Industrial Presented By OEM Architectural Noise & Vibration Control, Inc. 610-863-6300 www.brd-nonoise.com HVAC Marine

More information

MINIMUM SPECIFICATIONS

MINIMUM SPECIFICATIONS MINIMUM SPECIFICATIONS A) GREENHOUSE STRUCTURE: (EDUCATOR) 30 X 96 Galvanized Steel Frame Consisting of: A. Column Post: Allied 2 x 4 Rectangle 6 Spacing B. Bows: Allied 2 x 3 Rectangle 6 Spacing C. Trusses:

More information

SECTION VIBRATION ISOLATION

SECTION VIBRATION ISOLATION SECTION 15240 VIBRATION ISOLATION PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15450 - Plumbing Equipment. 2. 15510 - Piping (HVAC). 3. 15515 Valves, Hangers, and Specialties. 4. 15540 - Pumping

More information

COOLING TECHNOLOGY INSTITUTE

COOLING TECHNOLOGY INSTITUTE PAPER NO: TP08-16 CATEGORY: DRY COOLING COOLING TECHNOLOGY INSTITUTE THE COST OF NOISE ROBERT GIAMMARUTI HUDSON PRODUCTS CORPORATION JESS SEAWELL COMPOSITE COOLING SOLUTIONS, LLC The studies and conclusions

More information

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Rosemount 1154 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10

More information

Filter Media 452 sq. ft. (42 sq. m) Accu-Rated Airflow 900 cfm (425 L/sec.) Sound Level Approximately 77 dba at 5 ft. (1.5 m)

Filter Media 452 sq. ft. (42 sq. m) Accu-Rated Airflow 900 cfm (425 L/sec.) Sound Level Approximately 77 dba at 5 ft. (1.5 m) FILTAIR Capture 5 Issued July 2016 Index No. AY/3.5 Welding Safety and Health Quick Specs Industrial Applications Heavy equipment manufacturing Fabrication Maintenance and repair operations Processes Stick

More information

VENTILATION AIR CONDITIONING AIR CLEANING HEATING

VENTILATION AIR CONDITIONING AIR CLEANING HEATING Heat Recovery Units VENTILATION AIR CONDITIONING AIR CLEANING HEATING Cross flow heat recovery units Applications New Designed for energy saving and indoor air quality control within ventilation systems.

More information

Fiberglass Cooling Towers

Fiberglass Cooling Towers Fiberglass Cooling Towers Available in sizes from 100 to 240 tons. FC Series 700 Fiberglass Cooling Tower Available in sizes from 170 to 240 tons. No other fiberglass cooling tower comes with as many high-quality

More information

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Absorption Chillers TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series Stable Chilled Water Outlet Temperature PID control is applied to maintain constant chilled water outlet temperature. When the cooling

More information

Solar Flat Plate Thermal Collector

Solar Flat Plate Thermal Collector Solar Flat Plate Thermal Collector 1 OBJECTIVE: Performance Study of Solar Flat Plate Thermal Collector Operation with Variation in Mass Flow Rate and Level of Radiation INTRODUCTION: Solar water heater

More information

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m.

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m. Air Source Heat Pumps in the Commercial Market Thursday, February 5, 2015 9:00-10:30 a.m. 1. Commercial Equipment Applications, Benefits, Limitations 2. Case Studies 3. Efficiency Vermont Technical & Financial

More information

medixx Series Installation Guidelines medixx 50 medixx 60 medixx 70 Suitable for the following Siemens MRI Systems, or similar models:

medixx Series Installation Guidelines medixx 50 medixx 60 medixx 70 Suitable for the following Siemens MRI Systems, or similar models: medixx Series Installation Guidelines Suitable for the following Siemens MRI Systems, or similar models: medixx 50: Symphony / Harmony Quantum and Aera (XJ gradient) medixx 60: Avanto, Espree, TaTs, Vero,

More information