Air Conditioners. Technical Data. Pair application EEDEN RXS-J

Size: px
Start display at page:

Download "Air Conditioners. Technical Data. Pair application EEDEN RXS-J"

Transcription

1 Air Conditioners Technical Data Pair application EEDEN RXS-J

2 Air Conditioners Technical Data Pair application EEDEN RXS-J

3 TABLE OF CONTENTS RXS-J 1 Features Specifications Nominal Capacity And Nominal Input Technical Specifications Electrical Specifications Electrical data Electrical Data Capacity tables Cooling/Heating Capacity Tables Dimensional drawings Dimensional Drawings Centre of gravity Centre of Gravity Piping diagrams Piping Diagrams Wiring diagrams Wiring Diagrams - Single Phase Sound data Sound Pressure Spectrum Operation range Operation Range Split - Sky Air Outdoor Unit 1

4 k i ni l p- rp ao t o J i dr - l ti pua Outdoor Unit Pair application RXS-J 1 Features c S U S X OS RP Energy efficient units: up to class A energy labels Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Outdoor units for pair application Energy efficient units: full range A class energy labels Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode. Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency 2 Split - Sky Air Outdoor Unit

5 2 Specifications Outdoor Unit Pair application RXS-J FTXS20J2V1B / RXS20J2V1B FTXS25J2V1B / RXS25J2V1B FTXS35J2V1B / RXS35J2V1B FTXS42J2V1B / RXS42J2V1B FTXS50J2V1B / RXS50J2V1B 2-1 Nominal Capacity And Nominal Input Cooling capacity Min. kw Btu/h 4,400 4,400 4,800 5,800 5,800 kcal/h 1,120 1,120 1,200 1,460 1,460 Nom. kw 2.0 (3) 2.5 (3) 3.5 (3) 4.2 (3) 5.0 (3) Btu/h 6,800 (3) 8,500 (3) 11,900 (3) 14,300 (3) 17,100 (3) kcal/h 1,720 (3) 2,150 (3) 3,010 (3) 3,010 (3) 4,300 (3) Max. kw Btu/h 9,600 10,900 13,600 17,100 18,100 kcal/h 2,410 2,750 3,440 4,300 4,560 Heating capacity Min. kw Btu/h 4,400 4,400 4,800 5,800 5,800 kcal/h 1,120-1,200 1,460 1,460 Nom. kw 2.7 (4) (4) 5.4 (4) 5.8 (4) Btu/h 9,200 (4) 11,600 (4) 13,600 (4) 18,400 (4) 19,800 (4) kcal/h 2,320 (4) - 3,440 (4) 3,440 (4) 4,990 (4) Max. kw Btu/h 14,700 16,000 17,700 20,500 22,200 kcal/h 3,700-4,470 5,160 5,590 Power input Cooling Min. kw Nom. kw Max. kw Heating Min. kw Nom. kw Max. kw EER COP Annual energy consumption kwh Energy label Cooling A A A A A Heating A A A A A Piping connections Liquid OD mm Gas OD mm Drain OD mm Heat insulation Both liquid and gas Both liquid and gas Both liquid and gas Both liquid and gas Both liquid and gas pipes pipes pipes pipes pipes Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 5m 2-2 Technical Specifications RXS25J2V1B RXS42J2V1B RXS20J2V1B RXS35J2V1B RXS50J2V1B Casing Colour Ivory white Ivory white Ivory white Ivory white Ivory white Dimensions Unit Height mm Width mm Depth mm Packed unit Height mm Width mm Depth mm Weight Unit kg Packed unit kg Split - Sky Air Outdoor Unit 3

6 2 Specifications Outdoor Unit Pair application RXS-J 2-2 Technical Specifications RXS25J2V1B RXS42J2V1B RXS20J2V1B RXS35J2V1B RXS50J2V1B Heat exchanger Length mm Rows Quantity Fin pitch mm Stages Quantity Tube type ø7 Hi-XA ø8 Hi-XA ø7 Hi-XA ø7 Hi-XA ø8 Hi-XA Fin Type Waffle louvered fin Waffle louvered fin Waffle louvered fin Waffle louvered fin Waffle louvered fin Treatment Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Anti-corrosion treatment (PE) Fan Type Propeller fan Propeller fan Propeller fan Propeller fan Propeller fan Air flow rate Cooling High m³/min cfm 1,183 1,317 1,278 1,271 1,797 Super m³/min Low cfm 1,155 1,063 1,063 1,080 1,727 Heating High m³/min cfm 999 1,105 1, ,589 Super m³/min Low cfm 1, ,522 Fan motor Model D23H-28 D50R-28 D23H-28 D23H-28 KFD C Output W Speed Cooling High rpm Heating High rpm Sound power level Cooling High dba Sound pressure level Cooling High dba Silent operation dba Heating High dba Silent operation dba Compressor Model 1YC23AEXD 2YC36BXD 1YC23AEXD 1YC23AEXD 2YC36BXD Type Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Hermetically sealed swing compressor Output W 600 1, ,100 Operation range Cooling Ambient Min. ºCDB -10 (0.000) -10 (0.000) -10 (0.000) -10 (0.000) -10 (0.000) Max. ºCDB 46 (0.000) 46 (0.000) 46 (0.000) 46 (0.000) 46 (0.000) Heating Ambient Min. ºCWB Max. ºCWB Refrigerant Type R-410A R-410A R-410A R-410A R-410A Charge kg Refrigerant oil Type FVC50K FVC50K FVC50K FVC50K FVC50K Charged volume l Piping connections Liquid OD mm Gas OD mm Drain Type Hole Hole Hole Hole Hole Level difference IU - OU Max. m Heat insulation Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes Both liquid and gas pipes 2-3 Electrical Specifications RXS25J2V1B RXS42J2V1B RXS20J2V1B RXS35J2V1B RXS50J2V1B Power supply Phase 1~ 1~ 1~ 1~ 1~ Frequency Hz Voltage V Current Nominal running Cooling A 3.0 (1) 2.8 (2) 2.7 (3) 6.0 (1) 5.7 (2) 5.5 (3) 2.5 (1) 2.4 (2) 2.3 (3) 4.3 (1) 4.1 (2) 3.9 (3) 6.7 (1) 6.4 (2) 6.1 (3) current (RLA) Heating A 3.9 (1) 3.8 (2) 3.6 (3) 7.1 (1) 6.8 (2) 6.5 (3) 3.4 (1) 3.3 (2) 3.1 (3) 4.7 (1) 4.5 (2) 4.3 (3) 7.0 (1) 6.7 (2) 6.4 (3) Starting current Cooling A Heating A Wiring connections For power supply Quantity For connection with Quantity indoor Remark Earth wire included Earth wire included Earth wire included Earth wire included Earth wire included Notes (1) 220V, (2) 230V, (3) 240V 4 Split - Sky Air Outdoor Unit

7 3 Electrical data 3-1 Electrical Data RXS20J2V1B Outdoor Unit Pair application RXS-J Representative Unit Combination Power Supply Comp OFM IFM Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA FTXS20J2V1B RXS20J2V1B Max. 50Hz 264V Min. 50Hz 198V RLA is based on the following conditions, temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D055006D Split - Sky Air Outdoor Unit 5

8 3 Electrical data 3-1 Electrical Data Outdoor Unit Pair application RXS-J RXS42J2V1B Representative Unit Combination Power Supply Comp OFM IFM Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA FTXS42J2V1B RXS42J2V1B Max. 50Hz 264V Min. 50Hz 198V RLA is based on the following conditions, temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D059709B 6 Split - Sky Air Outdoor Unit

9 3 Electrical data 3-1 Electrical Data RXS50J2V1B Outdoor Unit Pair application RXS-J Representative Unit Combination Power Supply Comp OFM IFM Unit Outdoor Unit Hz - Volts Voltage Range MCA MFA RHz RLA W FLA W FLA FTXS50J2V1B RXS50J2V1B Max. 50Hz 264V Min. 50Hz 198V FVXS50FV1B RXS50J2V1B Max. 50Hz 264V Min. 50Hz 198V RLA is based on the following conditions, temp. 27 C DB/19.0 C WB. Outdoor temp. 35 C DB. 2. Maximum allowable voltage variation between phases is 2%. 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan Motor IFM : Fan Motor FLA : Full Load Amps (A) W : Fan Motor Rated Output (W) RHz : Rated Operating Frequency (Hz) 3D Split - Sky Air Outdoor Unit 7

10 3 Electrical data 3-1 Electrical Data Outdoor Unit Pair application RXS-J 8 Split - Sky Air Outdoor Unit

11 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FTXS20J2V1B + RXS20J2V1B Cooling 50 Hz 220V-240V AFR 9.4 BF 0.14 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 9.9 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D Split - Sky Air Outdoor Unit 9

12 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FTXS25J2V1B + RXS25J2V1B Cooling 50 Hz 220V-240V AFR 10.8 BF 0.16 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 11.9 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D Split - Sky Air Outdoor Unit

13 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FFQ25B8V1B + RXS25J2V1B Cooling 50 Hz 220V-240V AFR 9 BF 0.24 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 9 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D055487C Split - Sky Air Outdoor Unit 11

14 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FLXS25BAVMB + RXS25J2V1B Cooling 220V-240V 50 Hz AFR 7.6 BF 0.32 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 220V-240V 50 Hz AFR 9.2 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D055037C 12 Split - Sky Air Outdoor Unit

15 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FVXS25FV1B + RXS25J2V1B Cooling 50 Hz 220V-240V AFR 8.2 BF 0.10 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 8.8 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D056491C Split - Sky Air Outdoor Unit 13

16 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FVXS35FV1B + RXS35J2V1B Cooling 50 Hz 220V-240V AFR 8.5 BF 0.11 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 9.4 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D056492C 14 Split - Sky Air Outdoor Unit

17 4 Capacity tables Outdoor Unit Pair application RXS-J 4-1 Cooling/Heating Capacity Tables FBQ35C7VEB + RXS35J2V1B Cooling 50 Hz 220V-240V AFR 11.5 BF 0.15 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 11.5 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 3D055493C 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. Split - Sky Air Outdoor Unit 15

18 4 Capacity tables Outdoor Unit Pair application RXS-J 4-1 Cooling/Heating Capacity Tables FDXS35E7VMB + RXS35J2V1B Cooling 220V-240V 50Hz AFR 8.7 BF 0.17 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 220V-240V 50Hz AFR 8.7 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D055043C 16 Split - Sky Air Outdoor Unit

19 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FFQ35B8V1B + RXS35J2V1B Cooling 50 Hz 220V-240V AFR 10 BF 0.25 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 10 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl owrate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D055489C Split - Sky Air Outdoor Unit 17

20 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FHQ35BVV1B + RXS35J2V1B Cooling 220V-240V 50 Hz AFR 13 BF 0.20 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 220V-240V 50 Hz AFR 13 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D055046C 18 Split - Sky Air Outdoor Unit

21 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FLXS35BAVMB + RXS35J2V1B Cooling 50 Hz 220V-240V AFR 8.6 BF 0.35 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 9.8 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. (1) Corresponding refrigerant piping lenght: 5m (2) Level difference: 0m 2. shows nominal (rated) capacities and power input. 3D055039C Split - Sky Air Outdoor Unit 19

22 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FTXS35J2V1B + RXS35J2V1B Cooling 50 Hz 220V-240V AFR 11.4 BF 0.21 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 12.1 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D070670A 20 Split - Sky Air Outdoor Unit

23 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FTXS42J2V1B + RXS42J2V1B Cooling 50 Hz 220V-240V AFR 11.3 BF 0.14 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 12.2 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D Split - Sky Air Outdoor Unit 21

24 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FDXS50C7VMB + RXS50J2V1B Cooling 50 Hz 220V-240V AFR 12.0 BF 0.11 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 12.0 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables. (Figures out of the tables should not be used for calculation.) 4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D052271D 22 Split - Sky Air Outdoor Unit

25 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FFQ50B8V1B + RXS50J2V1B Cooling 50 Hz 230V AFR 12.0 BF 0.16 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 230V AFR 12.0 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables. (Figures out of the tables should not be used for calculation.) 4. SHC is based on each EWB and EDB. SHC*=SHC correction for other dry bulb. =0.02*AFR(m 3 /min.)*(1-bf)*(db*-edb) Add SHC*TO SHC. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D060463B Split - Sky Air Outdoor Unit 23

26 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FLXS50BAVMB + RXS50J2V1B Cooling 50 Hz V AFR 11.4 BF 0.18 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz V AFR 12.1 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the fi gures in the above tables. (Figures out of the tables should not be used for calculation.) 4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air fl ow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D051896D 24 Split - Sky Air Outdoor Unit

27 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FTXS50J2V1B + RXS50J2V1B Cooling 50 Hz 220V-240V AFR 11.6 BF 0.18 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 12.1 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Ratings shown are net capacities which include a deduction for indoor fan motor heat. 2. shows nominal (rated) capacities and power input. 3. TC, PI and SHC must be calculated by interpolation using the figures in the above tables. (Figures out of the tables should not be used for calculation.) 4. About SHC which are not mentioned on the table, please calculate them with around values in direct proportion. 5. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 5m Level difference: 0m 6. Air flow rate (AFR) and Bypass factor (BF) are tabulated above table. 3D Split - Sky Air Outdoor Unit 25

28 4 Capacity tables 4-1 Cooling/Heating Capacity Tables FVXS50FV1B + RXS50J2V1B Cooling 50 Hz 220V-240V AFR 10.7 BF 0.13 Outdoor temperature: ( CDB) EWB EDB C C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50 Hz 220V-240V AFR 11.8 Outdoor temperature: ( CWB) EDB C TC PI TC PI TC PI TC PI TC PI Symbols AFR: Air fl ow rate (m 3 /min.) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heat capacity (kw) PI: Power input (kw) 1. Capacities are based on the following conditions. Corresponding refrigerant piping lenght: 7.5 m Level difference: 0 m 2. shows nominal (rated) capacities and power input. 3D056339B 26 Split - Sky Air Outdoor Unit

29 5 Dimensional drawings 5-1 Dimensional Drawings RXS20-42J2V1B Drain outlet (I.D Ø 15.9 hose for connection) 4-holes for anchor bolts (M8 or M10) Minimum space for air passage Wall height on air outlet side = less than 1200 Handle Brand name label Manufacture s label Liquid stop valve (Ø 6.4CuT) Outdoor air thermistor Wiring inlet Service port In case of removing stop valve cover Gas stop valve (Ø 9.5CuT) 3D055546C RXS50J2V1B Drain outlet (I.D. Ø 15.9 hose for connection) Minimum space for air passage Wall height on air outlet side = less than holes for anchor bolts (M8 or M10) Brand name label Name plate Wiring inlet In case of removing stop valve cover Terminal strip with earth terminal Outdoor air temperature thermistor Liquid stop valve (Ø 6.4CuT) Service port Gas stop valve (Ø 12.7CuT) 3D051657Q Split - Sky Air Outdoor Unit 27

30 6 Centre of gravity 6-1 Centre of Gravity RXS20-35J2V1B Outdoor Unit Pair application RXS-J 4D056351R RXS42J2V1B 4D059009E 28 Split - Sky Air Outdoor Unit

31 6 Centre of gravity 6-1 Centre of Gravity RXS50J2V1B Outdoor Unit Pair application RXS-J the position of foundation bolt 4D051638Q Split - Sky Air Outdoor Unit 29

32 7 Piping diagrams 7-1 Piping Diagrams RXS20J2V1B OUTDOOR UNIT Outdoor Unit Pair application RXS-J 7.0 CuT Heat exchanger Outdoor temperature thermistor 9.5 CuT 7.0 CuT Heat exchanger thermistor 7.0 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve on: heating 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling Heating 3D059587B RXS25-35J2V1B OUTDOOR UNIT 7.0 CuT Heat exchanger Outdoor temperature thermistor 9.5 CuT 7.0 CuT Heat exchanger thermistor 4.8 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve on: heating 4.8 CuT 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling Heating 3D059586G 30 Split - Sky Air Outdoor Unit

33 7 Piping diagrams 7-1 Piping Diagrams RXS42J2V1B OUTDOOR UNIT Outdoor Unit Pair application RXS-J Heat exchanger Outdoor temperature thermistor 12.7 CuT Heat exchanger thermistor 4.8 CuT 6.4 CuT 6.4 CuT Motor operated valve 9.5 CuT Muffl er Propeller fan 9.5 CuT Four way valve on: heating 4.8 CuT 9.5 CuT Muffl er with fi lter Muffl er with fi lter 6.4 CuT Ø 4.0 x ID. 2.0 CuT Muffl er with fi lter Liquid stop valve Field piping (6.4 CuT) Discharge pipe thermistor Compressor Accumulator 9.5 CuT 9.5 CuT Muffl er Gas stop valve Field piping (9.5 CuT) Refrigerant fl ow Cooling Heating 3D059590B RXS50J2V1B OUTDOOR UNIT 12.7 CuT Heat exchanger thermistor Propeller fan Heat exchanger Outdoor air temperature thermistor 4.0 CuT 4.0 CuT Capillary tube CuT 4.0 CuT Capillary tube 2 Capillary tube 3 Capillary tube 4 Muffl er with fi lter 6.4 CuT 6.4 CuT 6.4 CuT Motor operated valve Refrigerant fl ow Cooling Heating 12.7 CuT Filter 12.7 CuT 9.5 CuT 6.4 CuT Muffl er Muffl er Four way valve on: heating 12.7 CuT Muffl er 9.5 CuT 12.7 CuT 6.4 CuT Reciever Liquid stop valve Field piping (6.4 CuT) Field piping Discharge pipe thermistor Compressor Gas stop valve with service port (12.7 CuT) 3D051637S Split - Sky Air Outdoor Unit 31

34 8 Wiring diagrams 8-1 Wiring Diagrams - Single Phase RXS20-35J2V1B FIELD WIRING indoor outdoor C5, C6,C119 : Capacitor DB1, DB2, DB3 : Diode Bridge FU1, FU2, FU3 : Fuse IPM1, IPM2 : Instelligent Power Module L : Live L1 : Coil L1R : Reactor M1C : Compressor Motor M1F : Fan motor MRCW, MR30, MRM10, MRM20 : Magnetic Relay N : Neutral Q1L : Overload Protector PCB1, PCB2, PCB3 : Printed Circuit Board S10, S11, S20, S40, S50, S70, S80, S90, S100, S110, HL3, RXS42J2V1B HN3, X11A, X12A : Connector R1T, R2T, R3T : Thermistor SA1 : Surge Arrester SW1 : Forced operation switch V1, V3, V4 : Varistor X1M : Terminal Strip Y1E : Electronic Expansion Valve Coil Y1R : Reversing solenoide valve coil Z1C, Z2C, Z3C : Ferrite Core : Protective Earth In case of cooling only type BLK : Black BLU : Blue BRN : Brown GRN : Green (outdoor) (discharge) (condenser) ORG : Orange RED : Red WHT : White YLW : Yellow 1. Refer to the nameplate for power requirements. 2. Size: Length 105 x width Refer to purchasing specification AS(Y)303002, unless otherwise specifi ed. 4. This drawing was drawn on CAD system. 3D065704B indoor Power supply outdoor (outdoor) (discharge) (condenser) C74, C75,C94, C95 : Capacitor DB1, DB2, DB3 : Diode Bridge FU1, FU2, FU3 : Fuse IPM1 : Instelligent Power Module L : Live L1 : Coil L1R : Reactor M1C : Compressor Motor M1F : Fan motor MRCW, MRM10, MRM20, MR30 : Magnetic Relay N : Neutral PCB1 : Printed Circuit Board Q1L : Overload Protector FIELD WIRING R1T~R3T : Thermistor SA1 : Surge Arrester Q31 : IGBT V1, V3, V4 : Varistor X1M : Terminal Strip Y1E : Electronic Expansion Valve Coil Z1C, Z2C, Z3C, Z4C : Ferrite Core S20, S40, S70, S80, S90 X11A : Connector : Protective Earth BLK : Black BLU : Blue BRN : Brown GRN : Green ORG : Orange RED : Red WHT : White YLW : Yellow 1. Refer to purchasing specification AS303002, unless otherwise specifi ed. 2. This drawing was drawn on CAD system. 3. The electric wiring diagram label is 3P D059601A 32 Split - Sky Air Outdoor Unit

35 8 Wiring diagrams 8-1 Wiring Diagrams - Single Phase RXS50J2V1B Power supply To indoor unit sheet metal indoor FIELD WIRING LED outdoor (outdoor) (discharge) (condenser) Z1C~Z5C X1M, X2M Y1E V2, V3, V5, V6, V11 SA2 FU1, FU2, FU3 AC1, AC2 U, V, W, X11A, X12A E1, E2 : Ferrite Core : Terminal Strip : Electronic Expansion Valve Coil : Varistor : Surge Arrester : Fuse HR1, HR2 : Connector MRM10, MRM20 MRC/W : Magnetic Relay R1T~R3T : Thermistor S2~S102 Leda L N SW1 SW4 M1C M1F L1R Q1L PM1 PCB1, 2 Y1R Sheet metal : Connector : Pilot lamp : Live : Neutral : Forced operation on/off SW (SW1) : Localsetting SW (SW4) : Compressor motor : Fan motor : Reactor : Overload protector : Power module : Printed circuit board : Reversing sorenoid valve coil : Terminal strip fi xed plate 1. Refer to purchasing specification AS303002, unless otherwise specifi ed. 2. This drawing was drawn on CAD system. 3. The electric wiring diagram label is 3P D056095D Split - Sky Air Outdoor Unit 33

36 9 Sound data 9-1 Sound Pressure Spectrum RXS20-25J2V1B Cooling Heating Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source 220~240V, 50Hz 4 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Cooling 6 Operation noise differs with operation and ambient conditions. 50Hz Scale V A 46 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source 220~240V, 50Hz 4 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Heating 50Hz Scale V A 47 3D059599B RXS35J2V1B Cooling Heating Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source 220~240V, 50Hz 4 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Cooling 6 Operation noise differs with operation and ambient conditions. 50Hz Scale V A 48 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source 220~240V, 50Hz 4 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Heating 50Hz Scale V A 48 3D059593D 34 Split - Sky Air Outdoor Unit

37 9 Sound data 9-1 Sound Pressure Spectrum RXS42J2V1B Cooling Heating Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source 220~240V, 50Hz 4 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Cooling 6 Operation noise differs with operation and ambient conditions. 50Hz Scale V (H) A 48 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in anechoic room. 3 Operating conditions: Power source 220~240V, 50Hz 4 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Heating 50Hz Scale V (H) A 48 3D059597B RXS50J2V1B Cooling Heating Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band sound pressure level (0 db = bar) Approximate threshold hearing for continuous noise Octave band center frequency - IEC (Hz) Octave band center frequency - IEC (Hz) 1 Over All (db): (B,G,N is already rectified) 2 Measuring place: measure in an echoic room. 3 Operating conditions: Power source 220~240V, 50Hz 4 Location of microphone. JISC9612 The operation noise measuring method is in accordance with JISC Cooling 50 Hz V 6 Operation noise differs with operation and ambient conditions. 50Hz Scale V A 48 1 Over All (db): (B,G,N is already rectified) 2 Operating conditions: Power source 220~240V, 50Hz 3 Heating 50 Hz V 50Hz Scale V A 48 3D059740B Split - Sky Air Outdoor Unit 35

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data O u t d o o r U n i t E E D E N 2-0 0 RX-GV Outdoor Unit RX-GV TABLE OF CONTENTS RX-GV Features............................................................. 2 2 Specifications.......................................................

More information

technical data air conditioning systems RKS-F2V1B Split Sky Air

technical data air conditioning systems RKS-F2V1B Split Sky Air technical data RKS-F2VB air conditioning systems Split Sky Air Split - Sky Air The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe

More information

Air Conditioning. Technical Data EEDEN RXS-L

Air Conditioning. Technical Data EEDEN RXS-L Air Conditioning Technical Data EEDEN15-100 RXS-L TABLE OF CONTENTS RXS-L 1 Features............................................................. 2 2 Specifications.......................................................

More information

Split. Air Conditioning Technical Data RXM-M9

Split. Air Conditioning Technical Data RXM-M9 Split Air Conditioning Technical Data RXM-M9 TABLE OF CONTENTS RXM-M9 1 Features............................................................. 2 2 Specifications.......................................................

More information

Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende Air Conditioners Technical Data Technical Data O u t d o o r u n i t - P a i r a p p l i c a t i o n T E C H N I C A L DATA - O U T D O O R U N I T - PA I R A P P L I C AT I O N O u t d o o r u n i t -

More information

technical data air conditioning systems Outdoor Units RKS-F3V1B RKS-FAV1B

technical data air conditioning systems Outdoor Units RKS-F3V1B RKS-FAV1B technical data Outdoor Units RKS-F3V1B RKS-FAV1B air conditioning systems technical data Outdoor Units RKS-F3V1B RKS-FAV1B air conditioning systems Outdoor Units R-410A RKS-F3V1B_RKS-FAV1B TABLE OF CONTENTS

More information

Heating. Technical Data. Daikin Altherma hybrid heat pump EEDEN EVLQ-CV3

Heating. Technical Data. Daikin Altherma hybrid heat pump EEDEN EVLQ-CV3 Heating Technical Data Daikin Altherma hybrid heat pump EEDEN14-729 EVLQ-CV3 Outdoor Unit EVLQ-CV3 TABLE OF CONTENTS EVLQ-CV3 1 Features............................................................. 2

More information

Air Conditioning. Technical Data. Pair, Twin, Triple, double twin EEDEN15-100B RZQG-L9V1

Air Conditioning. Technical Data. Pair, Twin, Triple, double twin EEDEN15-100B RZQG-L9V1 Air Conditioning Technical Data Pair, Twin, Triple, double twin EEDEN5-00B RZQG-L9V TABLE OF CONTENTS RZQG-L9V Features............................................................. 2 2 Specifications.......................................................

More information

Air Conditioning Technical Data RZQG-L9V1

Air Conditioning Technical Data RZQG-L9V1 Air Conditioning Technical Data RZQG-L9V TABLE OF CONTENTS RZQG-L9V Features............................................................. 2 2 Specifications.......................................................

More information

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3 MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 9,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 9,000 BTUH Multiaqua Model

More information

MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3

MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 18,000 BTUH. Rev. 1.3 MHWW-18-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 18,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 18,000 BTUH Multiaqua Model

More information

MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3

MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 12,000 BTUH. Rev. 1.3 MHWW-12-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 12,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 12,000 BTUH Multiaqua Model

More information

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit AUG25AGB-W AUG25ALD-W AUG25RLD-W AUY25AGB-W AUY25ALD-W AUY25RLD-W AUT25ALD-W AUT25RLD-W AUG30AGB-W AUG30ALD-W AUG30RLD-W

More information

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000

More information

Air Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15

Air Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15 ir Cooled Chiller (50Hz) ir Cooled Scroll ir Cooled Screw CC 05/15 ir Cooled Scroll Chiller ir Cooled Scroll Chiller - Product Lineup No Model Heat Compressor Electrical exchanger quantity(pcs) Maximum

More information

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models :

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models : ROOM AIR CONDITIONER AK SERIES (50Hz) Models : AKY9FBSSW AKY9UBSSW CONTENTS SPECIFICATIONS.......................... CIRCUIT DIAGRAM........................ MICROCOMPUTER CONTROL CIRCUIT...... DISASSEMBLY

More information

Non-Ducted Indoor Compressor Type DC Inverter Driven Rotary Rated Cooling Capacity BTUH RLA 10.8

Non-Ducted Indoor Compressor Type DC Inverter Driven Rotary Rated Cooling Capacity BTUH RLA 10.8 Submittal Data: Multi-Room Ductless heat-pump systems 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES

More information

FTXM-K + RXM-L. Product catalogue 2015

FTXM-K + RXM-L. Product catalogue 2015 FTXM-K + RXM-L Product catalogue 2015 Why choose Daikin Our promise is to ensure that your customers can depend on Daikin for the ultimate in comfort. We dedicate ourselves to technological excellence,

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1CO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI18HP230V1CO 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 18,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation

More information

Multi-Room Ductless heat-pump systems Submittal Data: MULTI24HP230V1CO 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date

Multi-Room Ductless heat-pump systems Submittal Data: MULTI24HP230V1CO 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Multi-Room Ductless heat-pump systems Submittal Data: 24,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Reference Approval Construction Unit Designation

More information

MUZ-GE09NAH MUZ-GE09NAH2 MUZ-GE12NAH MUZ-GE12NAH2 MUZ-GE15NAH MUZ-GE15NAH2 MUZ-GE18NAH MUY-GE18NA, - 1 MUY-GE24NA

MUZ-GE09NAH MUZ-GE09NAH2 MUZ-GE12NAH MUZ-GE12NAH2 MUZ-GE15NAH MUZ-GE15NAH2 MUZ-GE18NAH MUY-GE18NA, - 1 MUY-GE24NA SPLIT-TYPE AIR CONDITIONERS Revision F: MUZ-GE//5, MUZ-GE//5NAH and MUY-GE//5 have been added. Please void OBB549 REVISED EDITION-E. OUTDOOR UNIT PARTS CATALOG No. OBB549 REVISED EDITION-F Models MUZ-GENA

More information

Siesta. Sky Air. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Siesta. Sky Air. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration Siesta All Seasons Climate comfort Sky Air Heating Air Conditioning Applied Systems Refrigeration ABOUT DAIKIN Daikin has a worldwide reputation based on 85 years experience in the successful manufacture

More information

Product Catalog. Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz SSP-PRC027-EN. June 2012

Product Catalog. Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz SSP-PRC027-EN. June 2012 Product Catalog Odyssey Split System Heat Pumps R-22 Dry Charge 7½ - 20 Ton, 60 Hz June 2012 SSP-PRC027-EN General Data Table 1. General Data 7½ - 20 Ton Condensing Units 60 Hz 7½ Tons 10 Tons 15 Tons

More information

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow

More information

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Cabinet air leakage less than 2.0% at 1.0 inch H₂O when cooling and heat pump applications.

Cabinet air leakage less than 2.0% at 1.0 inch H₂O when cooling and heat pump applications. AVPEC Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal EEV, ComfortNet and Inverter Compatible to 5 Tons Contents Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

INDOOR UNITS FVXS25F FVXS35F FVXS50 F

INDOOR UNITS FVXS25F FVXS35F FVXS50 F Cooling Only INDOOR UNITS FVXS25F FVXS35F FVXS50 F Capacity cooling min~nom~max kw 1.3~2.5~3.0 1.4~3.5~3.8 1.4~5.0~5.6 Power input cooling min~nom~max kw 0.300~0.570~0.920 0.300~1.020~1.250 0.310~1.220~1.880

More information

CEILING WALL type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

CEILING WALL type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE ROOM AIR CONDITIONER CEILING WALL type Models Indoor unit Outdoor unit RJW-8CC RJW-CC RJW-0CC ROW-8CC ROW-CC ROW-0CC C O N T E N T S SPECIFICATIONS........................................ OUTLINE

More information

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE: ABOUT THE i-chiller RANGE The fully packaged, EcoDesign compliant, air-cooled i-chiller range is designed specifically for reliable and efficient process cooling. The unique evaporator is immersed within

More information

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that. Set Free Modular FSXN Engineering for tomorrow. And the tomorrow after that. 0 03 Introducing a new addition to Hitachi s Set Free range of VRF air conditioning units - enhancing efficiency and user experience

More information

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18.

EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Nominal Btu/hr. Min. Circuit Ampacity 18. ENVIRONMENTALLY SOUND REFRIGERANT H4A3 Product Specifications EFFICIENT 13 SEER 3 PHASE AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 3 THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 3 phase, 60 Hz

More information

01 Introduction TARGET. Multi Domestic. Commercial. 50, High Efficiency - High Efficiency Operation - Hot water with free of charge (HR)

01 Introduction TARGET. Multi Domestic. Commercial. 50, High Efficiency - High Efficiency Operation - Hot water with free of charge (HR) 01 Introduction TARGET POSITION FEATRE Multi Domestic EHS Mono/Split Low Temperature - Domestic, 50 water EHS High Temperature - Domestic, 80 water All-in-One More Efficient Free of Charge 50 or 80 Water

More information

Product Catalog Split System Air Conditioners Odyssey

Product Catalog Split System Air Conditioners Odyssey Product Catalog Split System Air Conditioners Odyssey R-22 Dry Charge CoolingCondenser 7.5, 10, 15 and 20 Tons 60 Hz July 2018 SS-PRC037J-EN Introduction Wide network availability Flexible applications

More information

Air Conditioners 4AC13

Air Conditioners 4AC13 PRODUCT SPECIFICATIONS R-40A Refrigerant 3 SEER.5 to 5 Tons High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity Top discharge directs hot air away

More information

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor

ELFOSpace WALL3. Technical Bulletin. Water terminal unit for indoor installation, wall-mounted CFW RANGE. DC Brushless Motor Technical Bulletin BT16N008GB-04 ELFOSpace WALL Water terminal unit for indoor installation, wall-mounted CFW 00.0 021.0 RANGE DC Brushless Motor High standards of efficiency and low noise New design Electronic

More information

Product Specifications

Product Specifications Product Specifications Models Unit Cooling Capacity kw 0.30~2.63~3.80 0.30~3.51~4.04 Btu/h. 1,023~9,000~12,966 1,023~12,000~13,785 Heating Capacity kw 0.30~3.22~6.50 0.30~3.98~6.50 Btu/h. 1,023~11,000~20,472

More information

Siesta. Sky Air. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Siesta. Sky Air. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration Siesta All Seasons Climate comfort Sky Air Heating Air Conditioning Applied Systems Refrigeration ABOUT DAIKIN Daikin has a worldwide reputation based on 85 years experience in the successful manufacture

More information

Split System Air Conditioner GSC13: 3-5 Tons GSC10: 7½ & 10 Tons

Split System Air Conditioner GSC13: 3-5 Tons GSC10: 7½ & 10 Tons GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons ontents Nomenclature... 2 Product Specifications... 3 Performance Data... 5 Wiring Diagram... 6 Dimensions... 8 Accessories...

More information

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner

Split System. GSC13: 3-5 Tons GSC10: 7½ & 10 Tons. Air Conditioner GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube/aluminum fin coil For

More information

Learn more about Samsung air conditioner at:

Learn more about Samsung air conditioner at: 2014 SAMSUNG New Ducted Air-Conditioner Learn more about Samsung air conditioner at: www.samsung.com/global/business/system-air-conditioner CONTENTS Smart Cooling - Global Top Efficiency - Powerful Cooling

More information

LG Renewable Heating Solutions

LG Renewable Heating Solutions RENEWABLE > SHIFT AWAY FROM FOSSIL FUELS LG Renewable Heating Solutions Products in this brochure contain fluorinated greenhouse gases (R410A) and (R134a) LG Air Conditioning and Energy Solutions UK Energy

More information

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics Condensers & dry coolers ODIN Excellent energy yield & sound characteristics O jççéä=áåçáå~íáçå `çåíéåíë= page Model indication................................. 2 Eurovent.......................................

More information

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS

More information

MULTI SPLIT INVERTER SYSTEMS

MULTI SPLIT INVERTER SYSTEMS MULTI SPLIT INVERTER SYSTEMS Energy Saving For conventional air-conditioning unit, the compressor will be running at the maximum frequency all the time. This requires a lot of energy and subsequently,

More information

PUHZ-HRP71VHA PUHZ-HRP100VHA PUHZ-HRP100YHA PUHZ-HRP125YHA

PUHZ-HRP71VHA PUHZ-HRP100VHA PUHZ-HRP100YHA PUHZ-HRP125YHA SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PARTS CATALOG R0A Outdoor unit [model names] PUHZ-HRP7VHA PUHZ-HRP00VHA PUHZ-HRP00YHA PUHZ-HRP5YHA PUHZ-HRP7VHA PUHZ-HRP00VHA PUHZ-HRP00YHA PUHZ-HRP5YHA [Service

More information

PARTS CATALOG. R410A Outdoor unit [Model Name] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December 2013

PARTS CATALOG. R410A Outdoor unit [Model Name] SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. December 2013 SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS PARTS CATALOG R0A Outdoor unit [Model Name] PUHZ-SHW80VHA PUHZ-SHWVHA PUHZ-SHWYHA PUHZ-SHW0YHA Salt proof model PUHZ-SHW80VHA-BS PUHZ-SHWVHA-BS PUHZ-SHWYHA-BS PUHZ-SHW0YHA-BS

More information

TECHNICAL CATALOGUE SELF-CONTAINED HORIZONTAL UNITS AIR - AIR DC INVERTER

TECHNICAL CATALOGUE SELF-CONTAINED HORIZONTAL UNITS AIR - AIR DC INVERTER TECHNICAL CATALOGUE SELF-CONTAINED HORIZONTAL UNITS AIR - AIR DC INVERTER Models : 1, 741, 1 ACHIA - Cooling only (Compact) CCHIA / ECHIA - Cooling only (Split) ACHIBA - Heat pump (Compact) CCHIBA / ECHIBA

More information

HITACHI Modular Chiller Solutions

HITACHI Modular Chiller Solutions Cooling Capacity 95kW - 1920kW Heating Capacity 92kW - 2384kW HITACHI Modular Chiller Solutions Giving you complete control The benefits of our unique modular design Projects change and develop over time.

More information

Product Data. (Unit shown with optional economizer.)

Product Data. (Unit shown with optional economizer.) COOLING ONLY/ELECTRIC HEAT PACKAGED ROOFTOP UNIT 15 TO 27.5 NOMINAL TONS Product Data (Unit shown with optional economizer.) C09316 Use of the AHRI Certified TM Mark indicates a manufacturer s participation

More information

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units.

Product Catalog. Variable Refrigerant Flow (VRF) System VRF-PRC008C-EN. Air Source Heat Pump and Heat Recovery Outdoor Units. Product Catalog Variable Refrigerant Flow (VRF) System Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH/4TVR0072 0192 4TVH/4TVR0216 0528 Single Unit Modules Multi-Unit Modules January 2016 VRF-PRC008C-EN

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

Free Cooling Technology

Free Cooling Technology Free Technology Utilise low ambient temperatures to save energy and reduce your cooling costs by up to 70% Free for industrial process and air conditioning How Free can save you money Free is a fast and

More information

CPRT SERIES 13 SEER PRODUCT SPECIFICATIONS. Split System Heat Pump. 2 to 5 Ton

CPRT SERIES 13 SEER PRODUCT SPECIFICATIONS. Split System Heat Pump. 2 to 5 Ton CPRT SERIES SEER Split System Heat Pump to Ton The CPRT split system heat pump is designed for ground-level or rooftop mount applications. Standard Features High-efficiency Copeland scroll compressor Louvered

More information

Ductless Heat Pumps OTP Series

Ductless Heat Pumps OTP Series Ductless Heat Pumps OTP Series Ouellet... A source of comfort for over 50 years! Ouellet Canada is recognized as the undisputed North American leader in the design, manufacture, and distribution of electric

More information

Product Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS

Product Data. 38AUZ / 38AUD 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons FEATURES / BENEFITS Z / D 60 Hz Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to20NominalTons Product Data FEATURES / BENEFITS Z07-14 shown C09227 the environmentally sound refrigerant Carrier s air-cooled air

More information

Product Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN.

Product Catalog. Variable Refrigerant Flow (VRF) Air Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* VRF-PRC008B-EN. Product Catalog Variable Refrigerant Flow (VRF) ir Source Heat Pump and Heat Recovery Outdoor Units 4TVH*/4TVR* February 2015 VRF-PRC008B-EN Introduction Copyright Trane VRF variable refrigerant systems

More information

Product Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs)

Product Data. 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons FEATURES/BENEFITS. Factory-installed options (FIOPs) 38AUZ Air Cooled Condensing Unit Puronr (R---410A) Refrigerant 6to12.5NominalTons Product Data Carrier s air-cooled air conditioning split systems: S provide a logical solution for commercial needs S have

More information

TECHNICAL & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL No. OC76 REVISED EDITION-C HFC utilized R0A June 00 [Model name] PUMY-P00VHM PUMY-P0VHM PUMY-P00VHMA A PUMY-P0VHMA PUMY-P00VHMA-BS

More information

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H)

TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) TECHNICAL SUPPORT MANUAL Duct Free Split Systems - DFS4(A/H) DFF4(A/H) - indoor and DFC4(A/H) -outdoor DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used

More information

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer.

Product Data. 50TC Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons. (Unit shown with optional economizer. Cooling Only/Electric Heat Packaged Rooftop 15 to 25 Nominal Tons Product Data (Unit shown with optional economizer.) C09262 the environmentally sound refrigerant This product has been designed and manufactured

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortBridge Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortBridge Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortBridge Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

High Efficiency. 7 % on average. EFFICIENCY RATIO WHAT'S IMPROVED? APF: Annual Performance Factor. NS Type

High Efficiency. 7 % on average. EFFICIENCY RATIO WHAT'S IMPROVED? APF: Annual Performance Factor. NS Type EFFICIENCY RATIO APF: Annual Performance Factor APF 6.0 4.5 3.0 5.9 5.5 5.7 5.2 5.1 6.0 5.6 5.5 5.0 4.9 5.4 5.4 5.3 5.5 5.5 5.5 5.2 5.1 High Efficiency of Overall lineup, with APF improved by 7 % on average.

More information

DVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons

DVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons DVPTC Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 2 to 5 Tons Contents Air Handler Nomenclature...2 Heater Kit Nomenclature...2 Product Specifications...3

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible. 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible. 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible Contents 1½ to 5 Tons Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications... 3

More information

New ADVANCED HYPER TROPICAL SPEC WINDOW. A new model realizes the high performance and energy saving which are more suitable for tropical climate.

New ADVANCED HYPER TROPICAL SPEC WINDOW. A new model realizes the high performance and energy saving which are more suitable for tropical climate. DVNCED HYPER TROPICL SPEC new model realizes the high performance and energy saving which are more suitable for tropical climate. New XGS18BTH / PTH / QTH XGS4BTH / PTH / QTH WINDOW High ambient 60 C operation

More information

DAT Commercial ELECTRIC AIR HANDLERS FOR 7½ & 10-TON SPLIT SYSTEMS

DAT Commercial ELECTRIC AIR HANDLERS FOR 7½ & 10-TON SPLIT SYSTEMS DAT Commercial ELECTRIC AIR HANDLERS F 7½ & 0-TON SPLIT SYSTEMS Contents Nomenclature... Product Specifications... Airflow Data... Heating Kit Data...6 Dimensions...7 Wiring Diagrams...8 Standard Features

More information

Product Catalog. VRF Water Source Unit 6to48Tons VRF-PRC017A-EN. November 2014

Product Catalog. VRF Water Source Unit 6to48Tons VRF-PRC017A-EN. November 2014 Product Catalog VRF Water Source Unit 6to48Tons November 2014 VRF-PRC017A-EN Introduction System Features 1,2 Copyright Modules are hybrid systems, shipping as standard heat pump configuration, field convertible

More information

CEILING WALL type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

CEILING WALL type SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SPLIT TYPE ROOM AIR CONDITIONER CEILING WALL type Models Indoor unit Outdoor unit RJW-HB RJW-8CB RJW-8HB RJW-CB RJW-HB RJW-0CB RJW-0HB ROW-HB ROW-8CB ROW-8HB ROW-CB ROW-HB ROW-0CB ROW-0HB C O N T E N T

More information

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit

More information

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

DCG Commercial. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE DG ommercial 7½ - ½ Ton Packaged Gas/ Electric Up to. EER / 80% AUE ooling apacity: 88,000,000 BTU/h Heating apacity (Output): 68,000 BTU/h ontents Nomenclature... Product Specifications... Expanded ooling

More information

4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT

4DHP MULTI-ZONE PRODUCT SPECIFICATIONS OUTDOOR UNITS INDOOR UNITS 4DHP MULTI-ZONE DWM WALL MOUNTED CEILING CASSETTE DUCTED UNIT DHP MULTI-ZONE PRODUCT SPECIFICATIONS UP TO SEER UP TO DUCTLESS HEAT PUMP SYSTEMS UNITS FORM NO. DHPMULTI-00 (0/07) DHP MULTI-ZONE 8K / 0K / 6K / 8K Mid Efficiency (- SEER) Matches with all indoor units

More information

SERVICE MANUAL MUZ-GA50VA - MUZ-GA60VA - MUZ-GA60VA - MUZ-GA60VA - MUZ-GA71VA - MUZ-GA71VA - E2 OUTDOOR UNIT. No. OB389.

SERVICE MANUAL MUZ-GA50VA - MUZ-GA60VA - MUZ-GA60VA - MUZ-GA60VA - MUZ-GA71VA - MUZ-GA71VA - E2 OUTDOOR UNIT. No. OB389. SPLIT-TYPE AIR CONDITIONERS Revision : The fan guard for MUZ-A50VA- E, MUZ-A60VA- E and MUZ-A7VAhas been changed. E Please void OB89 REVISED EDITION-F. OUTDOOR UNIT SERVICE MANUAL Models E MUZ-A50VA -

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump

MIRAI SMI. Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump MIRAI SMI Monobloc heat pump for Heating and Cooling Residential environments with plant management system integrated in the heat pump Air conditioning Technical sheet 20C GB02 Indice Monobloc heat pump

More information

TECHNICAL SUPPORT MANUAL Fan Coils FSM2X, FSM4X

TECHNICAL SUPPORT MANUAL Fan Coils FSM2X, FSM4X Fan Coils FSM2X, FSM4X DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAU- TION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on

More information

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit

More information

WT Model Water-to-Water Heat Pump

WT Model Water-to-Water Heat Pump WT Model Water-to-Water Heat Pump 2 to 6 ton Enhanced WT Model includes wider range of voltages and optional double-wall load side heat exchanger to this two-stage, ultra-efficient unit for best-in-class

More information

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features Series Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV ½ to Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Airflow Data...

More information

Flooded Type Water-Cooled Chillers. R134a

Flooded Type Water-Cooled Chillers. R134a Flooded Type WaterCooled Chillers The HighEfficiency WaterCooled Flooded Chillers The New WaterCooled Flooded chiller with improved efficiency and functionality by incorporating several advanced technology

More information

VRF 50/60Hz V5 E Series

VRF 50/60Hz V5 E Series 1702-1V1701 VRF 50/60Hz V5 E Series Coercial Air Conditioners 2017/2018 VRF 50/60Hz V5 E Series Coercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde,

More information

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany Universal cooler in individual design BASELINE BL 006 BL 1440 Customized refrigeration technology Made in Germany 2 Lahntechnik your system partner for customized refrigeration technology For more than

More information

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants N SERIES Air Cooled Condensing Units - Technical Catalog Featuring Bitzer TM s 404A and 507 Refrigerants 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Standard

More information

VENTILATION AIR CONDITIONING AIR CLEANING HEATING

VENTILATION AIR CONDITIONING AIR CLEANING HEATING Heat Recovery Units VENTILATION AIR CONDITIONING AIR CLEANING HEATING Cross flow heat recovery units Applications New Designed for energy saving and indoor air quality control within ventilation systems.

More information

No. F ISSUED: Apr. 7, 2009 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AWA MODEL

No. F ISSUED: Apr. 7, 2009 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER KMD-201AWA MODEL No. F022-3207 ISSUED: Apr. 7, 2009 REVISED: Nov. 26, 2013 HOSHIZAKI MODULAR CRESCENT CUBER MODEL KMD-201AWA S LIST (GENERAL) U-1 APR. 2009 V-0 JAN. 2010 V-1 FEB. 2010 V-2 JUL. 2010 A-0 JAN. 2011 A-1 APR.

More information

1500G-3000G USER'S MANUAL. Trouble shooting

1500G-3000G USER'S MANUAL. Trouble shooting Trouble shooting Problem Possible reason Solution System is not functioning 1.Controller box set at 0..The pressure of feed water isn't high enough. ( more than 1.5kg/cm ) 1.Make an adjustment..check water-in

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortBridge Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortBridge Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortBridge Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

Air Conditioners 4AC14L

Air Conditioners 4AC14L 4AC4L PRODUCT SPECIFICATIONS R-40A Refrigerant Compressor with internal pressure relief valves and inherent thermal protection High-quality condenser coil with copper tubing and enhanced louvered fin for

More information

Outdoor air treatment units

Outdoor air treatment units Outdoor air treatment units A +++ A ++ A + A B C D ErP Fresh Air Unit The FAU series of outdoor air treatment units, with Lossnay enthalpic energy recovery module, direct expansion coil and integrated

More information

Modular Active Chilled Beams

Modular Active Chilled Beams Modular Active Chilled Beams Presented by: Darren Alexander, P.Eng. Modular Active Chilled Beams Current System Solutions Fan Coil Units - Medium/High energy, medium noise solution. Output = 100-200 w/m

More information

Investigation on effects of piping on heating performance of multi-split variable refrigerant flow system

Investigation on effects of piping on heating performance of multi-split variable refrigerant flow system 12 th IEA Heat Pump Conference, 15 th -18 th May, 2017, Rotterdam Investigation on effects of piping on heating performance of multi-split variable refrigerant flow system Ziai Li Department of Building

More information

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw YKN2open Features High efficiency EER and COP Low noise level All configurations: Cooling only, Cooling + gas, Heating, Heating +

More information

Smardt Water Cooled Chillers

Smardt Water Cooled Chillers Smardt Water Cooled Chillers 60-1140tonR(200-4,000kWr) 1 8 compressors Control cabinet Evaporator Condenser Smardt Air Cooled Chillers 60-430TR (200-1500kWr) 1 4 compressors Condenser with EC-fans Evaporator

More information

Integrated Air Conditioning System

Integrated Air Conditioning System Integrated Air Conditioning System a smart solution for every building Contents TVR System 03 TVR System Advantage 04 TVR System Applications 05 Features - Inverter System 07 Features - Higher Reliability

More information

YKN2open A R C 032 A B

YKN2open A R C 032 A B york air-conditioning products ACTIVA Rooftop ARC-ARG-ARH-ARD A complete range from 17 kw up to 40 kw YKN2open Features High efficiency EER and COP Low noise level EC supply fan All configurations: Cooling

More information

PUHZ-P100VHA1.UK PUHZ-P125VHA1.UK PUHZ-P140VHA1.UK

PUHZ-P100VHA1.UK PUHZ-P125VHA1.UK PUHZ-P140VHA1.UK SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS December 00 No.OC REVISED EDITION-B SERVICE MANUAL R0A Outdoor unit [model names] 00VHA VHA 0VHA [Service Ref.] 00VHA.UK 00VHA.UK VHA.UK VHA.UK 0VHA.UK 0VHA.UK Revision:

More information

Stack Parking Surface Mounted Stackers

Stack Parking Surface Mounted Stackers 1 / 6 Stack Parking Surface Mounted Stackers swiss-park V-2 Comfort The V-2 is designed to park cars of any size thanks to its vertical adjustability. It will accommodate cars as tall as the garage ceiling

More information

MINNESOTA STATE SECTION ADVERTISEMENT FOR BIDS

MINNESOTA STATE SECTION ADVERTISEMENT FOR BIDS MINNESOTA STATE SECTION 00 11 13 ADVERTISEMENT FOR BIDS Sealed Bids for: will be received by: Ridgewater College Commercial Chiller Purchase Ridgewater College Willmar Campus 2101 15 th Ave. N.W Willmar,

More information

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1.

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1. PAGE 1 of 5 1.1. REFERENCE STANDARDS 1.1.1. The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1. 1.1.2. Unit shall be designed to conform to ASHRAE 15. 1.1.3. Unit

More information