1 KILLARK C Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. Features Completely interchangeable with competative bodies, gaskets, and covers Flat back design provides greater cubic capacity for easier wire pulling and more room for splicing Raintight when used with gasketed covers Stainless steel screws on stamped and cast covers Smooth integral wire bushings Material/Finish uraloy Gray Iron Alloy Tri-coat finish of electrozinc, chromate sealant, and electrostatically applied powder coating. C TYPE CONUIT BOY* C18 1/2 C28 C38 C /4 C58 1-1/2 C68 2 C78 C /16 (43) 1-31/32 (50) 2-3/8 (60) 3-27/32 (98) 5 (127) 5 (127) C Type F10

2 KILLARK S T LO C LB Type LL Type LB Type LL Type LB TYPE CONUIT BOY* LB18 1/2 LB28 LB38 LB /4 LB58 1-1/2 LB68 2 LB78 LB888 LB98 3-1/2 LB (429) 16- (429) 7-13/16 (198) 4-25/32 (121) 7-13/16 (198) 1-5-7/16 (138) 5-7/16 (138) LL TYPE CONUIT BOY* (352) 13- (352) 7- (197) 13- (349) 13- (349) 1- LL18 1/2 LL28 LL38 LL /4 LL58 1-1/2 LL68 2 LL78 LL (56) 4-25/32 (121) (197) F11

3 KILLARK LR Type T Type LR Type T Type LR TYPE CONUIT BOY* LR18 1/2 LR28 LR38 LR /4 LR58 1-1/2 LR68 2 LR78 LR /16 (49) 1-11/16 (43) 1-31/32 (50) 2-3/8 (60) (52) 1- T TYPE CONUIT BOY* 8-7- (199) 1- T18 1/2 T28 T38 T /4 T58 1-1/2 T68 2 T78 T /32 (45) 2 (51) 2- (67) 2-5/16 (59) 5-1/8 (130) 6-11/16 (170) 6-11/16 (170) /16 (271) 10-11/16 (271) F12

4 KILLARK S T LO C TB Type TB Type TB TYPE CONUIT BOY* TB18 1/2 TB28 TB38 TB /4 TB58 1-1/2 TB /16 (75) 5-1/8 (130) 1-15/16 (49) 2-3/16 3- (98) 1- X TYPE CONUIT BOY* 8- (26) 1- X18 1/2 X28 X38 X /4 X58 1-1/2 X68 2 X Type 1-25/32 (45) 2 (51) 2- (67) 3-23/32 (94) 4-1/16 (103) 5-9/32 (134) 6-3/8 (162) 1-8- (26) X Type F13

5 KILLARK Cast Covers IRON COVERS AN GASKETS Cover Gaskets (Neoprene) Stamped Steel Covers Cast Material/Finish uraloy Gray Iron Alloy Tri-coat finish of electrozinc, chromate sealant, and electrostatically applied powder coating 300 Series stainless steel screws Galvanized Steel Natural finish 300 Series stainless steel screws Material/Finish Neoprene. Compression molded. NUMBER CAST IRON COVERS LENGTH WITH HEIGHT 180F 1/2 4-7/32 (107) 3/8 (10) 280F 3/8 (10) 380F 5-19/32 (142) 480F 1-1/4 2-3/16 (56) 580F 1-1/2 7-(200) 680F 2 9-(248) 3-(98) 880F 12-1/4 (311) 5 (127) 880F 12-1/4 (311) 5 (127) 980F 3-1/2 15 (381) 6-1/4 (159) 980F 4 15 (381) 6-1/4 (159) NUMBER STAMPE STEEL COVERS LENGTH WITH HEIGHT 180S 1/2 4-7/32 (107) 5/16 (8) 280S 5/16 (8) 380S 5-19/32 (142) 5/16 (8) 480S 1-1/4 2-3/16 (56) 5/16 (8) 580S 1-1/2 7-(200) 5/16 (8) 680S 2 9-(248) 3-(98) 5/16 (8) 880S 12-1/4 (311) 5 (127) 9/16 (14) 880S 12-1/4 (311) 5 (127) 9/16 (14) 980S 3-1/2 15 (381) 6-1/4 (159) 9/16 (14) 980S 4 15 (381) 6-1/4 (159) 9/16 (14) NUMBER COVER GASKETS LENGTH WITH HEIGHT GASK851N 1/2 4-7/32 (107) 1/8 (3) GASK852N 1/8 (3) GASK853N 5-19/32 (142) 1/8 (3) GASK854N 1-1/4 2-3/16 (56) 1/8 (3) GASK805N 1-1/2 7-(200) 1/8 (3) GASK806N 2 9-(248) 3-(98) 1/8 (3) GASK808N 12-1/4 (311) 5 (127) 1/8 (3) GASK808N 12-1/4 (311) 5 (127) 1/8 (3) GASK809N 3-1/2 15 (381) 6-1/4 (159) 1/8 (3) GASK809N 4 15 (381) 6-1/4 (159) 1/8 (3) NOTE - (2) screws 1/2 through 1-1/4, (4) screws 1-1/2 through 4 F14

ALUMINUM OR MALLEABLE IRON CONDUIT BODIES

ALUMINUM OR MALLEABLE IRON CONDUIT BODIES O SERIES / 5 SERIES ALUMINUM OR MALLEABLE CONDUIT BODIES Suitable for wet locations when used with gasketed Federal Specification W-C-586D/A-A 50563. Suitable for use in hazardous location applications

More information

ALUMINUM OR IRON CONDUIT BODIES

ALUMINUM OR IRON CONDUIT BODIES 7 SERIES ALUMINUM OR CONDUIT BODIES LR Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. Features Intermateability UL Listed

More information

Material/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating

Material/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating 3 LR Type Applications To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. eatures Intermateability UL Listed and CSA Certified interchangeability

More information

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED LB57 1-1/2 LB FM7 CND BD Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category LB57 Appleton/Oz Gedney Conduit Body, Electro Zinc Plated Dichromate Epoxy Powder Coated

More information

Mogul Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Mogul Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC Applications To provide access to large and heavy conductors for pulling, splicing, maintenance and future changes / upgrades Allows connection of straight conduit runs, branch conduit runs and 90 bends.

More information

Service Entrance Cable Fittings

Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.

More information

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry

Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry Expansion & Deflection Fittings SOLUTIONS for the Construction Industry TTINGS FI ST D LO C AF/AF8 SERIES e st d, in M a c h e d, As d in D e s i g n e d, b le the Casted Body with NPT hub size se m Ca

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 2 Insulated EMT Connector (Raintight) (Compression Type) Series 20 EMT Coupling (Raintight) (Compression Type) Series 0 Pipe

More information

(For Vertical Conduit) ENY-2 (Fixture Hanger) (See Page L146) (Drain/Seal for Vertical Conduit)

(For Vertical Conduit) ENY-2 (Fixture Hanger) (See Page L146) (Drain/Seal for Vertical Conduit) EY SERIES ITTINGS SELING ITTINGS 45 ENY ENY with Nipple EY EY with Nipple (or Vertical Conduit) ENY-2 (ixture Hanger) (See Page L146) EYS EYS with Nipple with Nipple (Drain/Seal for Vertical Conduit) Class

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533-RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section includes conduit raceways, and tubing, surface raceways, wireways, outlet boxes, pull and junction boxes, and

More information

Sand Cast Aluminum Form 7 Conduit Bodies

Sand Cast Aluminum Form 7 Conduit Bodies Sand ast luminum Form 7 onduit odies Sand ast luminum Form 7 onduit odies Superior corrosion protection Thomas & etts is pleased to introduce the new line of Sand ast luminum Form 7 onduit odies featuring

More information

Sand Cast Aluminum Form 7 Conduit Bodies

Sand Cast Aluminum Form 7 Conduit Bodies Sand ast luminum Form 7 onduit odies Sand ast luminum Form 7 onduit odies Superior corrosion protection Thomas & etts is pleased to introduce the new line of Sand ast luminum Form 7 onduit odies featuring

More information

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction.

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction. S and ast Hub evice oxes UNILTS for use with Threaded Rigid onduit and IM. ll device boxes have ridge top construction. pplications ccommodate wiring devices such as switches and receptacles. Provide excellent

More information

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 26 05 33 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes conduit and tubing, surface raceways, wireways, outlet boxes, pull and junction boxes, and handholes.

More information

Specifications Electrical Metallic Tubing (EMT)

Specifications Electrical Metallic Tubing (EMT) T& Fittings Specifications Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-000 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Red Dot. Rigid Fittings. Table of Contents

Red Dot. Rigid Fittings. Table of Contents Table of Contents Conduit Unions Hazardous Locations... C2 C3 Conduit Fittings Hazardous Locations... C4 C5 Sealing Fittings Hazardous Locations... C6 C7 Conduit Hubs Raintight for Threaded Rigid Conduits...

More information

maximum mechanical protection

maximum mechanical protection Rigid Metal Conduit maximum mechanical protection REXWAY Rigid Metal Conduit (RMC) is produced to meet the specifications laid out in ANSI C80.1 and UL 6. Manufactured from high strength mild steel strip,

More information

Flush Service Floor Boxes

Flush Service Floor Boxes Flush Service Floor Boxes PRODUCT SPECIFICATION: Flush Service Floor Boxes PART 1: Overview Considerations when writing specifications: Floor boxes are manufactured in various sizes, configurations and

More information

Kruppsconduit. Metal Raceway Product Range

Kruppsconduit. Metal Raceway Product Range Kruppsconduit Metal Raceway Product Range RIGID STEEL CONDUIT Rigid Steel Conduit - (RSC) RSC - Rigid Steel Conduit-this means high in strength, superior in protection, high in safety and durability. It

More information

EXBLT Series for Harsh and Hazardous Environments

EXBLT Series for Harsh and Hazardous Environments EXBLT Series for Harsh and Hazardous Environments OSUR CL HA ES EN KILLARK Z LO C EXBLT SERIES JUNCTION BOXES Predrilled internal mounting pan bosses as standard. Uses same mounting pans as the EXB series

More information

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications Cable Terminators and Sealing Fittings are used on conduit ends and cable ends to effectively seal the cable and conduit. Terminator The Terminator body is deep enough to provide an ample compound chamber

More information

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB Waterpipe Ground Clamps Cat. No. Ground Wire Size Water Pipe Size 2-TB 1/2 in., 3/4 in., 1 or rebar 4-10 3-TB 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, 4 2-1/2 in., 3 in. or 3-1/2 in. #2 WG 5-TB 4 in., 4-1/2

More information

INDEX METALS FERRIC METALS NON-FERRIC METALS WORKING WITH METALS METAL FORMING TECHNIQUES ENVIRONMENTAL IMPACT OF METAL EXTRACTION

INDEX METALS FERRIC METALS NON-FERRIC METALS WORKING WITH METALS METAL FORMING TECHNIQUES ENVIRONMENTAL IMPACT OF METAL EXTRACTION METALS INDEX METALS FERRIC METALS NON-FERRIC METALS WORKING WITH METALS METAL FORMING TECHNIQUES ENVIRONMENTAL IMPACT OF METAL EXTRACTION METALS CHEMICAL ELEMENTS FOUND IN NATURE IN SOLID STATE AT ROOM

More information

Features: Single-Gang Two-Gang Three-Gang Four-Gang Hubless Receptacles. Compliance: CSA Listed. B Index. February Master Index. Cat. No.

Features: Single-Gang Two-Gang Three-Gang Four-Gang Hubless Receptacles. Compliance: CSA Listed. B Index. February Master Index. Cat. No. FS and FD Cast Device Boxes: Malleable Iron, Aluminum B Features: Single-Gang Two-Gang Three-Gang Four-Gang Hubless Receptacles Compliance: CSA Listed B-2 B-3 FS and FD Cast Device Boxes: Index Page Description

More information

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. A. ANSI C Electrical Rigid Steel Conduit, Zinc Coated.

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. A. ANSI C Electrical Rigid Steel Conduit, Zinc Coated. SECTION 26 05 33 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 -GENERAL 1.1 SUMMARY A. Section includes conduit and tubing, surface raceways, wireways, outlet boxes, pull and junction boxes, and handholes.

More information

Design Standard Conduit for Electrical Systems

Design Standard Conduit for Electrical Systems Design Standard Purpose: This design standard has the purpose of creating a consistent application for the installation of conduits throughout the East Side Union High School District, therefore achieving

More information

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side

Steel Square Box, Height 4 Inch; Width 4 Inch; Depth 1-1/2 Inch; Capacity 21 Cu Inch; 17 Knockout(S); Knockout Location (5) Bottom, (12) Side 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Knockout Location Knockout Size 4SSPLDR

More information

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box

(3) 1/2 INCH CONDUIT BOTTOM, (2) 3/4 INCH CONDUIT BOTTOM, (8) 1 INCH CONDUIT SIDES Box 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SD1 4S Box 1"Ko 2-1/8DP Appleton/Oz Gedney Catalog Number 4SD1 Manufacturer Appleton/Oz Gedney Description Steel Square

More information

Procurement Services SVC East Fowler Avenue Tampa, Florida (813)

Procurement Services SVC East Fowler Avenue Tampa, Florida (813) Procurement Services SVC 1073 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481 Web Address: https://www.usf.edu/business-finance/purchasing/public-bids/rfi.aspx October 12, 2018 Invitation to

More information

Raceway and Boxes for Electrical Systems Page 1 of 7

Raceway and Boxes for Electrical Systems Page 1 of 7 Last Update: May 12, 2017 A. Conduits: Page 1 of 7 1. All conductors for each and every electrical system shall be installed in a raceway except communications and A/V systems which shall have stubs to

More information

AMFICO AMERICAN FITTINGS. Use ONE Fitting on ALL Conduits. It s EMT, It s Rigid, It s IMC, It s UL Approved, It s Steel, It s American.

AMFICO AMERICAN FITTINGS. Use ONE Fitting on ALL Conduits. It s EMT, It s Rigid, It s IMC, It s UL Approved, It s Steel, It s American. Use ONE Fitting on ALL Conduits It s EMT, It s Rigid, It s IMC, It s UL Approved, It s Steel, It s American. AMFICO 2 1/2 to 4 EMT, Rigid and IMC UL Listed Dual Rated 1/2-4 Connectors, Couplings, Connectors

More information

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved PART 1 GENERAL 1.01 DESCRIPTION A. Provide all raceways, fittings, and boxes of specified type required for complete project. Install all systems in raceways unless specifically noted otherwise. Provide

More information

Unflanged Junction or Pull Boxes

Unflanged Junction or Pull Boxes UA12 Unflanged Junction or Pull Boxes Cast Iron Box For Surface Mounting - NEMA 4 Type YS Raintight - Watertight - Dust Tight UA12 Use: These boxes are general purpose enclosures listed by Underwriters

More information

Youngstown State University

Youngstown State University SECTION 260533 - RACEWAYS PART 1 - GENERAL SUMMARY A. This section includes raceways for electrical wiring. Types of raceways in this section include the following: 1. Flexible metal conduit 2. Liquid

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, and cabinets for electrical wiring. B. See Division

More information

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS PART 1 - GENERAL 01.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification sections, apply to work of this Section.

More information

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit Ref. CEC Rule 12-1000 Rigid Metal Conduit affords maximum mechanical protection to conductors within the raceway. Rigid metal conduit can

More information

PRODUCT CATALOG STAINLESS STEEL CONDUIT & FITTINGS ALL STAINLESS STEEL ALL IN STOCK

PRODUCT CATALOG STAINLESS STEEL CONDUIT & FITTINGS ALL STAINLESS STEEL ALL IN STOCK PRODUCT CATALOG STAINLESS STEEL CONDUIT & FITTINGS ALL STAINLESS STEEL ALL IN STOCK When Gibson Stainless was founded in 1995, Type 316 SS electrical fittings were very hard to find. Zinc plated, galvanized,

More information

SECTION RACEWAYS AND BOXES

SECTION RACEWAYS AND BOXES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 26 05 33 RACEWAYS AND BOXES A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

LBHF LBHS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K. Ex d IIC U DIP A21

LBHF LBHS ATEX 94/9/EC GOST-R (RTR / RTN) GOST-K. Ex d IIC U DIP A21 OPEN BENDS AND PULLING BOXES Explosion Proof Electrical Equipment Ex Conduit fittings Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts) Classification: Group II - Category 2G 2D

More information

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal conduit B. Flexible metal conduit C. Liquid tight flexible metal conduit D. Electrical metallic tubing E. Non-metallic conduit F. Fittings and conduit bodies

More information

International Tube & Conduit Company Ltd. GALVANIZING EDGE IN TUBE TECHNOLOGY

International Tube & Conduit Company Ltd. GALVANIZING EDGE IN TUBE TECHNOLOGY GALVANIZING EDGE IN TUBE TECHNOLOGY ABOUT THE COMPANY ITCC is a major manufacturer of Steel Conduits, Steel Tubes, Scaffolding and Construction Props, as well as fence materials. It operates a state-of-the-art

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

GENERAL ISOMETRIC LAYOUT

GENERAL ISOMETRIC LAYOUT STRUCTURAL SPECIFICATIONS: 1. FLOODGATE MATERIAL TO BE ALUMINUM AS FOLLOWS: LID - ALUMINUM CONNECTED EXTRUSION - GRADE 6061 MIN. Fᵧ=35 KSI PAN STIFFENERS - 1 2" ALUM FLAT BAR - GRADE 6061 MIN. Fᵧ=35 KSI

More information

FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System

FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System FAST-08 F.A.S.T. Foldable, Adjustable, Stackable, Tool-Less System Product Focus F.A.S.T. System can be installed independent of the floor system. Stackable to create multiple tiers. No tools required

More information

Overview Better by Design

Overview Better by Design Overview Better by Design Ocal-Blue PVC-coated conduit and fittings represent a complete corrosion-protection package for your entire conduit system. This extensive product line includes the largest number

More information

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION SECTION 1101 SIGNALS AND APPURTENANCES PART 1 GENERAL 1.4 SUBMITTALS E. Submit warranty for all supplied material and workmanship for a period of two years from final acceptance. The warranty must state

More information

A. Coordinate arrangement, mounting, and support of electrical equipment:

A. Coordinate arrangement, mounting, and support of electrical equipment: SECTION 260500 -BASIC ELECTRICAL MATERIALS AND METHODS PART 1- GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Electrical equipment coordination and installation. 2. Sleeves for raceways

More information

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit Ref. CEC Rule 12-1000 Rigid Metal Conduit affords maximum mechanical protection to conductors within the raceway. Rigid metal conduit

More information

CHAPTER 11 CONDUITS AND FITTINGS

CHAPTER 11 CONDUITS AND FITTINGS CONDUITS AND FITTINGS CHAPTER 11 CONDUITS AND FITTINGS The standards and requirements for conduits and fittings used for traffic control signal and lighting systems are presented in this chapter. 11.1

More information

DMS CONDUIT EFFECTIVE DATE: APRIL

DMS CONDUIT EFFECTIVE DATE: APRIL DMS - 11030 EFFECTIVE DATE: APRIL 2014 11030.1. Description. This Specification governs the materials, composition, quality, sampling, and testing of electrical conduit. 11030.2. Units of Measurements.

More information

STREET LIGHTING GENERAL INFORMATION

STREET LIGHTING GENERAL INFORMATION SECTION 1102 STREET LIGHTING GENERAL INFORMATION These specifications are for street lighting that is to be dedicated to the public and maintained by the City of Meridian. Such installations require a

More information

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.

More information

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number

4CS12 4CS-1/2 4X1-7/8D Handybox. Features. Dimensions and Weight. Long Description. Catalog Number 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com 4CS12 4CS-1/2 4X1-7/8D Handybox Appleton/Oz Gedney Catalog Number 4CS12 Manufacturer Appleton/Oz

More information

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION ALTERNATING TREAD STEEL STAIRS SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this

More information

Prepared By: Approved By:

Prepared By: Approved By: Page No.: of 3 Issue Date: 06/0/8 Superseded Date: 03/0/6 Fittings, Malleable Iron, ANSI Classes 50 & 300. SCOPE This specification covers /8-inch through 4-inch Class 50 and /4-inch through 3-inch Class

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, cabinets, and track busway for electrical wiring.

More information

SECTION ROLLER GATES

SECTION ROLLER GATES GENERAL SUMMARY A. The Contractor shall provide all labor, materials, equipment, and incidentals required to furnish and install roller gates, complete and operational with all necessary accessories as

More information

I-2 Unions, Sealing Fittings, Flexible Couplings, Elbows, Drain/Breather, Close-Up Plugs: Explosionproof UNILETS for Use with Threaded Metal Conduit

I-2 Unions, Sealing Fittings, Flexible Couplings, Elbows, Drain/Breather, Close-Up Plugs: Explosionproof UNILETS for Use with Threaded Metal Conduit -2 Unions, Sealing Fittings, Flexible Couplings, Elbows, Drain/Breather, Close-Up Plugs: Explosionproof UNLETS for Use with Threaded Metal Conduit Applications: Unions UNY and UNF unions are used for joining

More information

SECTION FLAGPOLES. 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole.

SECTION FLAGPOLES. 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole. SECTION 10 75 00 FLAGPOLES SPEC WRITER NOTE: Delete text between // // not applicable to project. Edit remaining text to suit project. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional,

More information

P630 HIGH FLOW GAS REGULATOR

P630 HIGH FLOW GAS REGULATOR P60 HIGH FLOW GAS REGULATOR P60 HIGH FLOW GAS REGULATOR Stainless Steel Internals are Standard Steel Units comply with NACE MR0 Durable Powder Coated Exterior Wide Range of Flow Capacities The P60 is a

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI

CONSULTANT PROCEDURES & DESIGN GUIDELINES Electrical Manholes and Handholes UNIVERSITY OF MISSOURI GENERAL: The scope of this document is to provide instruction for the installation of concrete electric manholes. DESIGN GUIDELINES: 1. Materials for Manhole 1.1. Cast-in-Place or Pre-Cast concrete may

More information

FAST-09. Flextray F.A.S.T. System The Next Generation RF Solution

FAST-09. Flextray F.A.S.T. System The Next Generation RF Solution FAST-09 Flextray F.A.S.T. System The Next Generation RF Solution Product Focus F.A.S.T. System can be installed independent of the floor system. Stackable to create multiple tiers. No tools required for

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 11294 - Stainless Steel Sluice Gates C O N T E N T S PART 1 - GENERAL... 1 1.01 SUMMARY... 1 1.02 REFERENCES... 1 1.03 DEFINITIONS... 1 1.04 DESIGN REQUIREMENTS...

More information

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets. ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. SECTION 260529 - HANGERS AND SUPPORTS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases. 1.2

More information

8461C 4SQ, 1"RSD Rndopnw/Ers CVR

8461C 4SQ, 1RSD Rndopnw/Ers CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 4SQ, 1"RSD Rndopnw/Ers CVR Appleton/Oz Gedney Catalog Number Manufacturer Appleton/Oz Gedney Description Steel Square

More information

Flextray - Accessories

Flextray - Accessories Flextray - 40 Flextray - Protects cable from debris and dust Adds security to cable installation Easy bend-over tabs secure cover to trays Available for 2 (50mm) to 24 (600mm) wide trays Comes in 118 (2997mm)

More information

CONDUITS AND FITTINGS

CONDUITS AND FITTINGS CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit

More information

1. METALS 2. FERRIC METALS 3. NON-FERRIC METALS 4. WORKING WITH METALS 5. METAL FORMING TECHNIQUES 6. ENVIRONMENTAL IMPACT OF METAL EXTRACTION

1. METALS 2. FERRIC METALS 3. NON-FERRIC METALS 4. WORKING WITH METALS 5. METAL FORMING TECHNIQUES 6. ENVIRONMENTAL IMPACT OF METAL EXTRACTION METALS: 1. METALS 2. FERRIC METALS 3. NON-FERRIC METALS 4. WORKING WITH METALS 5. METAL FORMING TECHNIQUES 6. ENVIRONMENTAL IMPACT OF METAL EXTRACTION 1. METALS: Metals are chemical elements found in nature

More information

1511 Series. Consolidated * Valves. Safety Valve

1511 Series. Consolidated * Valves. Safety Valve GE Oil & Gas Technical Specifications 08/2014 Consolidated * Valves 1511 Series Safety Valve Offering proven, high-performance design for low-pressure, steam heating boilers and steam generators, as well

More information

Product Guide Specification

Product Guide Specification ACCESS CABLE TRAYS, Inc 1073 79 th St. S St. Petersburg, FL 33707 PH. 727 341 1111 FX. 727 344 8680 EMAIL. information@accesscabletrays.com Product Guide Specification ********************************************************************************************************************

More information

PRODUCT CATALOG & BUYER S GUIDE

PRODUCT CATALOG & BUYER S GUIDE PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN! Table of Contents Table of Contents Introduction Performance Matters!...4-15 Corrosion Protection...16 Conduit PVC

More information

PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN!

PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN! PVC Coated Rigid Metal Conduit PM-111 PRODUCT CATALOG & BUYER S GUIDE GO FOR THE GREEN! Table of Contents Table of Contents Introduction Performance Matters!...4-15 Corrosion Protection...16 Conduit PVC

More information

Sliding Door Systems

Sliding Door Systems Sliding Door Systems Standard Sliding System Reference Brand: Sapa Building System Plaisance 24 GENERAL DESCRIPTION Sliding window and door system with a frame depth of 50 mm (two rail version), 97mm (three

More information

Pipe. Valves. Fittings. Fasteners. Tube and Tube Fittings. And Much More

Pipe. Valves. Fittings. Fasteners. Tube and Tube Fittings. And Much More Pipe Valves Fittings Fasteners Tube and Tube Fittings And Much More Tubing Sizes Materials 1/16" to 6" Diameter Stainless A269 & A511 Copper Monel Inconel Hastelloy DK Lok Tube Fittings Sizes Products

More information

Introduction to Cast Junction Boxes

Introduction to Cast Junction Boxes UA2 Introduction to UA2 I Purpose of Enclosure Enclosures are used to protect personnel against accidental contact with enclosed electrical devices or connections and to protect the enclosed devices or

More information

UNIVERSITY OF MISSOURI Electrical Manholes and Handholes 2016 Q1

UNIVERSITY OF MISSOURI Electrical Manholes and Handholes 2016 Q1 GENERAL: The scope of this document is to provide instruction for the design and installation of medium voltage concrete electric manholes and handholes. DESIGN GUIDELINES: 1. Design for Manhole 1.1. The

More information

(800) fax (708) Available From: Allied Tube & Conduit Printed in U.S.A. 7/98 ATC-L

(800) fax (708) Available From: Allied Tube & Conduit Printed in U.S.A. 7/98 ATC-L A2106 Allied Tube tsteel he recycled material A1654 ISO 9002 (800) 882-5543 fax (708) 339-2399 Available From: Allied Tube & Conduit Printed in U.S.A. 7/98 ATC-L-1453-4 ONE What is Gatorshield...and Why

More information

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES

HANDHOLES, PULLING VAULTS AND JUNCTION BOXES Handholes and pulling vaults perform several important functions: Provide drainage for the conduit system so that freezing water does not damage the conduit or wires. Provide a location for bending the

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 22 0548 - PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section. SECTION - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

More information

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY SECTION 280528 - PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Metal conduits, tubing, and fittings. 2. Nonmetallic conduits, tubing, and fittings. 3.

More information

Table of Contents Scope of Design. Scope of Design Materials Dimensions & Weights Orifice Capacities

Table of Contents Scope of Design. Scope of Design Materials Dimensions & Weights Orifice Capacities Scope of Design CONSOLIDATED Type 1511 safety valves are designed for low pressure, steam heating boilers and steam generators as well as air service applications. Table of Contents Scope of Design......................1511.1

More information

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Elastomeric Isolation pads. 2. Elastomeric Isolation mounts. 3. [Freestanding] [Restrained] [Freestanding and restrained]

More information

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

B. Provide a complete conduit system with associated couplings, connectors, and fittings. SECTION 26 05 33 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 260500. B. Provide a complete conduit system with associated couplings, connectors, and fittings. 1.02 RELATED

More information

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION ALTERNATING TREAD STEEL STAIRS SECTION 05 51 33.23 - ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 SCOPE OF WORK Fabricate and install carbon steel or stainless steel alternating tread stair assemblies in accordance with the requirements

More information

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE SECTION 13 34 00 METAL SHADE STRUCTURE PART 1 - GENERAL 1.01 STRUCTURE TYPE A. Structure shall be free standing rigid frame and gable roof with slopes as indicated. Structure shall also include foundation,

More information

SECTION RACEWAYS

SECTION RACEWAYS SECTION 16110 RACEWAYS PART 1 GENERAL 1.1 SYSTEM DESCRIPTION A. Provide a complete raceway system suitable for receiving wire and cable and continuous from outlet to outlet. System shall be complete with

More information

Sleeve 15, 25, and 35 kv, 600-Amp, Deadfront Switchgear, Padvault

Sleeve 15, 25, and 35 kv, 600-Amp, Deadfront Switchgear, Padvault Material Specification Material Specification Standards Engineering Department Date: 13 Jul 12 Date: 13 Jul 12 Page i Material Specification Table of Contents Contents SECTION 1 Scope... 1 2 Applicable

More information

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens. SECTION 102113 TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Solid composite phenolic toilet compartments and urinal screens. 1.02 RELATED SECTIONS

More information

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used.

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used. SECTION 16110 RACEWAYS AND FITTINGS 1.00 RACEWAYS: All wiring shall be in raceways. Raceways shall be run in slabs, walls, above ceilings or exposed as indicated on drawings. Acceptable raceway and their

More information

SECTION SLUICE GATES

SECTION SLUICE GATES SECTION 11100 SLUICE GATES PART 1--GENERAL Fill in the blank with a short description of sluice gate usage, i.e., for isolation of wastewater, or for tank drainage, or for control of water surface. 1.01

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information