Level measurement CleverLevel LBFS Point level detection

Size: px
Start display at page:

Download "Level measurement CleverLevel LBFS Point level detection"

Transcription

1 Product highlights Save detection of liquids, bulk-solids and powders Short immersion length Ecellent cleanability Ability for differentiation between foam and liquid Not sensitive to adherent or sticky media Status signaling by bright, blue LED Compact stainless steel housing, sealed up to IP69K Measures media with DC-values >.5 (Dielectric Constant) User benefits One sensor for all applications Less disturbance of process Safe process with less downtime Visual observation of process Long life time even in wash-down areas DECEMBER Technical data Reverse polarity protection Housing Compact design Style Dimension Material Refer to dimensional drawings (page 4 f.) Stainless steel Switching polarity M, 4 pin, polycarbonate M, 4 pin, stainless steel 5 m, 4-wire, PVC Short circuit protection Voltage drop Protection class (IEC 6059) Vibration C C ± 00 μa ma. Off leak current Switching logic Normally open (NO) Normally closed (NC) Sensor performance < 98 % RH, condensing IP67 IP69K (with appropriate cable) IEC GL Test Process connection Repeatability Hysteresis Response time Damping ± mm ± mm 0. s typ. (0.5 ± 0.05 s) s (adjustable) Factory settings Connection variants Mounting position Wetted parts material Refer to dimensional drawings (page 4 f.) Any (top, bottom, side) PEEK Natura AISI 36L (.04) AISI 304 (.430) (optional) Surface roughness wetted parts PNP: (+Vs -.5 V) ± 0.5 V, Rload = 0 kω NPN: (+.5 V) ± 0.5 V, Rload = 0 kω Ra < 0.8 μm Process conditions Process temperature Process pressure Switching range (dielectric constant DC) 0. s Damping Compliance and approvals EMC Immunity EMC Emission Eplosion protection EN 636 EN 636 (installed on a metal tank) ATEX II G E ia IIC T4/T5 ATEX II D E ta IIIC T00 C Da ATEX II 3 G E na II T4/T5 Refer to table (page f.) Refer to table (page f.) < 75 % (DC > ) culus Listed, Class, E36569 Safety Power supply Hygiene Voltage supply range Railway Marine Current consumption (no load) V DC 5 ma typ., 50 ma ma. Note: Refer to table (page 3) EN 5055 Refer to table (page 3) Information on product characteristics may relate to defined product options Data sheet Page / 0 Humidity (IEC ) Yes Storage temperature range ma ma. Current rating Ambient conditions Operating temperature range PNP NPN Cable outlet <s Output signalization Electrical connection Connector variants Power-up time Yes

2 Process conditions Type Process connection Process temperature continuous Tamb < 50 C Process pressure Process temperature ma. temporary t < h Tamb < 50 C Process Process temperature ma. temporary BCID C bar C bar G07 G LBFS-. G / A ISO 8- LBFS-G. G / A ISO 8-, not applicable for mounting with ZPW-7 LBFS-A. G / A DIN 385-E, NBR gasket G5 LBFS-B. G / A DIN 385-E, FKM (Viton ) gasket G5 LBFS-4. G / A hygienic LBFS-K. G / A hygienic, length 8 mm - 5 LBFS-L. G / A hygienic, sliding connection, length 50 mm LBFS-5. G / A ISO 8- for reverse assembly (in-shell thread) T LBFS-. G 3/4 A ISO 8- G0 LBFS-3. G A ISO 8- G LBFS-N. /-4 NPT N0 LBFS-M. /-4 NPT N LBFS-6. 3/4-4 NPT N03 LBFS-7. M8 M LBFS-E. G / A DIN 385-E, FKM (Viton ) gasket G Process connection type,, 3, 4, 6, 7, A, B, G, K, M, N, E Process connection type L (sliding connection) 50 With cooling neck 40 (type G, M, E) No limitation Ambient temperature ( C) Projecting length min. (mm) Without cooling neck Process temperature ( C) Process temperature ma.( C) 60 Ambient temperature ( C) 5 min. Projecting length Data sheet ma. Page / 0

3 Compliance and approvals Type Process connection BCID LBFS-. G / A ISO 8- G07 LBFS-G. G / A ISO 8- G07 LBFS-A. G / A DIN 385-E, NBR gasket LBFS-B. EN 9/04 EN 0/ EN 3/06 FDA 3-A EHEDG EL-Class I DNV GL G5 G / A DIN 385-E, FKM (Viton ) gasket G5 LBFS-4. G / A hygienic LBFS-K. G / A hygienic, length 8 mm LBFS-L. G / A hygienic, sliding connection, length 50 mm LBFS-5. G / A ISO 8- for reverse assembly (in-shell thread) T0 LBFS-. G 3/4 A ISO 8- G0 LBFS-3. G A ISO 8- G LBFS-N. /-4 NPT N0 LBFS-M. /-4 NPT N0 LBFS-6. 3/4-4 NPT LBFS-7. LBFS-E. Note: Lloyd s Register CCS WHG (overfill, leakage) N03 M8 M G / A DIN 385-E, FKM (Viton ) gasket G5 Information on product characteristics may relate to defined product options The requirements of the respective 3-A Sanitary Standard will be only fulfilled in combination with appropriate mounting accessories. Those are marked with the 3-A logo. ATEX II G E ia IIC T4/T5 ATEX II D E ta IIIC T00 C Da Maimun values (for barrier selection) () Voltage supply range Temperature class Ui: 30 V DC Ii: 00 ma Pi: 0.75 W Internal capacitance Internal inductance Temperature class Ci: 43 nf Li: 0 µh T T4: -40 < Tamb < 85 C T T5: -40 < Tamb < 74 C Protection class of cable accessory The EHEDG certification is only valid in combination with appropriate mounting accessories. Those are marked with the "EHEDG Certified" logo 30 V DC ma. T00 C: -40 < Tamb < 85 C IP67 ATEX II 3 G E na II T4/T5 30 V DC ma. Voltage supply range Temperature class T T4: -40 < Tamb < 85 C T T5: -40 < Tamb < 74 C Data sheet () Recommended barrier: PROFSI3-B500-ALG-LS (please refer to accessories, page 0) Page 3 / 0

4 Field of application is designed for level detection in tanks and dry-run protection of pumps by empty pipe monitoring. It detects liquid, pasty or oily media, but also solid-bulk materials like flour or plastic granulate. The LBFS is capable of media differentiation by distinguishing the specific properties, such as oil, wate, foam and liquid. Reliable performance is assured in any mounting position (from top, bottom or side). Depending on the desired process connection, different mounting options are available. Corresponding mounting aids and adaptors for conventional process connections are available as an accessory. Two parallel switching outputs are available as Normally Open (NO) and Normally Closed (NC) which is defined by PN or NPN polarity when placing the order. in its default configuration covers a major part of potential applications. Where customer-specific configuration is require because of difficult media (e. g. foamy or adhering), the interface pr gramming tool FleProgrammer 0 allows for easy parameterization of the optimum switching points by convenient teach-in functionality. The measured data can be visualized on a PC for further parameter adjustment, for eample time constant of a damping function and inverted switching output logic. Measuring principle An electrode inside the sensor tip builds a capacitor together with the surroundings. The medium with its dielectric constant (DC value) is defining the capacitance value. A resonance circuit is created in combination with a coil in the sensor head. Switching signal tripping is according to the measured resonance frequency and the programmed trigger thresholds. G / A G / G / A Dimensional drawings 4 A/F 66 4 A/F 7 LBFS-G. G / A ISO 8- G / A ISO 8- LBFS-A. LBFS-B. G / A DIN 385-E, NBR / FKM (Viton ) gasket G / A G / A LBFS-. 4 A/F LBFS-4. LBFS-E. G / A hygienic G / A DIN 385-E, FKM (Viton ) gasket, Data sheet Page 4 / 0

5 Dimensional drawings 8 7 Ø8 Ø4,6 Ø4,6 Sealing ring Compression ring Screw-in plug LBFS-K. LBFS-L. G / A hygienic, length 8 mm G / A hygienic, sliding connection, length 50 mm A/F 7 A/F LBFS-3. G / A ISO 8- for reverse assembly (in-shell thread) G 3/4 A ISO 8- GA ISO 8- /-4 NPT A/F /4-4 NPT LBFS-. / NPT LBFS A/F 4 GA Ø7 G 3/4 A G / A A/F 7 LBFS-M. LBFS-6. /-4 NPT /-4 NPT 3/4-4 NPT LBFS-N. Data sheet Page 5 / 0

6 Dimensional drawings PVC LBFS-7. M8 M Polycarbonate or stainless steel Polycarbonate, transparent 7 M8 65 TPE AISI 36L LBFS-. LBFS-3. LBFS-. Connector M Cable outlet Electrical connection Terminal assignment 4 3 Connector M 3 4 Cable outlet Brown White Blue Black Function + Vs Normally closed (NC) 0V Normally open (NO) Switching characteristic Switching polarity PNP Normally closed (NC) PNP NPN NPN LED LED Normally open (NO) Switching logic Data sheet Page 6 / 0

7 LBFS Type Level switch Compliance and approvals Standard ATEX II G E ia IIC T4/T5 () ATEX II D E ta IIIC T00 C Da ATEX II 3 G E na II T4/T5 ATEX II G E ia IIC T4/T5 and ATEX II D E ta IIIC T00 C Da () culus Listed, Class, E36569 EAC (TR CU 0/) Electrical connection Connector M, 4 pin, polycarbonate (with LED) Cable outlet 5 m, 4-wire, PVC (3) Connector M, 4 pin, stainless steel (without LED) Process connection (BCID) G / A ISO 8- (G07) G / A ISO 8- (G07) G / A DIN 385 form E, NBR gasket (G5) G / A DIN 385 form E, FKM (Viton ) gasket (G5) G / A DIN 385 form E, FKM (Viton ) gasket, (G5) G / A hygienic () G / A hygienic, length 8 mm () G / A hygienic, sliding connection, length 50 mm () (T0) G / A ISO 8- for reverse assembly (in-shell thread) (4) G 3/4 A ISO 8- (G0) G A ISO 8- (G) /-4 NPT (N0) /-4 NPT (N0) 3/4-4 NPT (N03) M8 (M) Wetted parts material AISI 304 (.430) (available for Process connection,, 3, 5, 6, 7) AISI 36L (.04) Switching polarity PNP NPN -. LBFS A B 3 G A B E 4 K L 5 3 N M 6 7 Configuration Factory setting Customer-specific 0 C () The isolating barrier PROFSI3-B500-ALG-LS is recommended with PNP switching polarity for E ia IIC (please refer to accessories, page 0) (3) Ambient temperature: Bending radius min.: C (if the cable is unmoved) C (if the cable is moved) r 0 mm (4) Including gasket ZPX3-4B0 (glass/aramide fiber with NBR) Data sheet Page 7 / 0

8 Accessories Industrial weld-in sleeves for LBFS-., (BCID: G07) Thick wall tank - AISI 304 (.430) ZPW-7 Thick wall tank - AISI 36L (.04) ZPW-7 Hygienic adapters for LBFS-4., LBFS-K., LBFS-L. (BCID: ) DECEMBER DECEMBER Clamp, DIN 3676 DN 5, DN 40 ISO 85 DN 5, DN 38 ZPH3-33 DIN 3676 DN 50 ISO 85 DN 5 ZPH3-36 DIN 85 DN 5 DN 40 DN 50 ZPH3-3 ZPH3-34 ZPH3- SMS DN 5 ZPH-336 Varivent Type N Varivent Type F ZPH3-34E ZPH3-3F DIN 864--A DN 40 DN 50 ZPH3-4 ZPH3-5 DECEMBER DECEMBER Data sheet Page 8 / 0

9 Accessories Hygienic weld-in sleeves for LBFS-4., LBFS-K., LBFS-L. (BCID: ) Tanks, with leak detection port ZPW3-3 Thin wall tanks ZPW3-3 Tanks, pipes ZPW-34 Pipe with collar DN 5... DN 50 DN DN 50 ZPW-36 ZPW-37 DECEMBER DECEMBER Threaded adapters for LBFS-4., LBFS-K., LBFS-L. (BCID: ) Vibronic level switch replacement EH FTL G 3/4 A VS G 3/4 A EH FTL G A VS G A ZPH-3BA ZPH-3BC ZPH-3CB ZPH-3CD Industrial GA G / A GA ZPI-3B ZPI-3D ZPI-3E Data sheet Page 9 / 0

10 Accessories Spare parts G / A gland nut for LBFS-L. with sliding connection (BCID: ) ZPX-008 Compression ring kit for LBFS-L. with sliding connection (BCID: ) ZPX-006 Gasket for LBFS-5. for reverse assembly (BCID: T0) ZPX3-4B0 FleProgrammer 0 Programming kit for sensor parameterization. The set contains a FleProgrammer, all cables needed, carrying strap and the FleProgrammer software on a CD ATEX isolating barrier for LBFS-., LBFS-4. with PNP switching polarity for E ia IIC PROFSI3-B500-ALG-LS Interfaces For more detailed information please refer to the applicable product data sheet. Data sheet Page 0 / 0

Level measurement CleverLevel LBFS Point level detection

Level measurement CleverLevel LBFS Point level detection Product highlights Save detection of liquids, bulk-solids and powders Short immersion length Ecellent cleanability Ability for differentiation between foam and liquid Not sensitive to adherent or sticky

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request

More information

CombiTemp TCR6 Standard RTD temperature sensor

CombiTemp TCR6 Standard RTD temperature sensor CombiTemp TCR6 Main features Sensor and connection in stainless steel, ISI 316 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

Field case for temperature transmitter Model TIF11

Field case for temperature transmitter Model TIF11 Electrical temperature measurement Field case for temperature transmitter Model TIF11 WIKA data sheet TE 62.02 Applications Plant construction Process engineering General industrial applications Energy

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual Vibranivo Mononivo Series Series VN 4000 MN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos. průmyslová elektronika Capacitive level meters CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and

More information

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Magnetic float switch For vertical installation Model FLS for nuclear power plants Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost

More information

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables Data Sheet 907025 Page 1/12 Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables The hygrothermal transducers measure the relative air humidity and temperature

More information

CAPACITIVE LEVEL METERS CLM 36

CAPACITIVE LEVEL METERS CLM 36 CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by

More information

Capacitive level meter CLM 36

Capacitive level meter CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Variants with rope electrode or with coated electrode for aggressive

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

Differential pressure

Differential pressure Differential pressure 228 Overview Differential pressure 230 VEGADIF 65 232 Chemical seal 236 Oval flange adapter, mounting bracket, cutting ring screwing 238 Valve block 227 Overview Differential pressure

More information

Diaphragm pressure gauge

Diaphragm pressure gauge Diaphragm pressure gauge with switch function, NS 00/60,Type series BE2 Features Diaphragm pressure gauge with switch function High quality case with bajonet ring NS 00/60 per EN 837-3 S, alternative safety

More information

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring Level Measurement and Monitoring FN04 Liquid level sensor with continuous detection Level measurement unaffected by foam formation, conductivity, pressure or temperature Remote indication over very long

More information

PRODUCT RANGE CABLE GLANDS

PRODUCT RANGE CABLE GLANDS PRODUCT RANGE CABLE GLANDS INDUSTRIAL CABLE GLANDS The ideal solution for each application HUMMEL offers a huge range of Cable Glands for industrial applications. High-quality materials and innovative

More information

CAPACITIVE LEVEL SENSORS DLS 27

CAPACITIVE LEVEL SENSORS DLS 27 CAPACITIVE LEVEL SENSORS DLS 27 For limit level sensing of liquid, and bulk-solid and powder materials Xi version for usage in explosive areas Direct mounting into various containers, silos, vessels, tanks,

More information

Relative Turbidity Meter ITM-

Relative Turbidity Meter ITM- 1 Product Information ITM- ITM-G Relative Turbidity Meter ITM- Application / Specified Usage Authorizations Media with a turbidity > 2000 NTU / 500 EBC (equal to about 5,5 % of display ITM-2) Application

More information

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

Dual Pressure flexitim* System Bently Nevada* Asset Condition Monitoring

Dual Pressure flexitim* System Bently Nevada* Asset Condition Monitoring Dual Pressure flexitim* System Bently Nevada* Asset Condition Monitoring Description The Dual Pressure flexitim* module interfaces 2 individual pressure transducers to the Trendmaster * 2000 System and

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP) Data sheet Multi Ejector Solution TM for R744 (CO 2 ) - CTM 6 High (HP) Multi Ejector Solution TM, consists of a CTM 6 High valve and an AK-PC 782A controller. This solution makes CO 2 refrigeration systems

More information

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU TUFFy T3 side Mounting level controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact

More information

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP) Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low (LP) Danfoss Multi Ejector Solution TM, consists of a CTM 6 Low valve and an AK-PC 782A controller. This solution makes CO

More information

HS-429 Vibration Trip Manual

HS-429 Vibration Trip Manual HS-429 Vibration Trip Manual CONTENTS 1. SAFETY INSTRUCTIONS ------------------------------------------------------------------------- 2 2. FUNCTIONS AND FEATURES -------------------------------------------------------------------

More information

Turbidity Meter ITM-51

Turbidity Meter ITM-51 SENSORS FOR FOOD ND BIOPHRM. Product Information ITM-51 ITM-51R FOOD Turbidity Meter ITM-51 pplication / Specified Usage uthorizations Turbidity measurement of liquid media for mid to high turbidity range

More information

HSK-INOX Hygienic-Design

HSK-INOX Hygienic-Design HSK-INOX Hygienic-Design Cope with all hygienic requirements Cable Glands for special applications Tested quality: EHEDG certified Enclosures of Hygienic Cable Glands are without corners and edges as well

More information

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K T Premium Panel, protection category IP 69K IP 69 K.6 H H H Optionally with or without keyboard housing Resistant to high-pressure cleaning (protection category IP 69K). The seal lies between two surfaces

More information

Presented By. NicolScales.com Contact Us

Presented By. NicolScales.com Contact Us Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of

More information

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

K-FLEX SOLAR SYSTEM SOLAR SYSTEM K-FLEX SOLAR SYSTEM SOLAR SYSTEM K-FLEX offers a line of products designed specifically for solar heating, renewable energy sources used to produce hot water using solar energy. The product range consists

More information

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features HLX300ExHT The HLX300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240

Flow Assembly for ph and Redox Sensors FlowFit P CPA 240 Technical Information TI 179C/07/en Flow Assembly for ph and Redox Sensors FlowFit P CPA 40 ph flow assembly for demanding processes with high requirements. Sensor holder with three electrode mounting

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-4 FOOD 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR AND BIOPHARMA. Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase

More information

Relative Turbidity Meter ITM-3

Relative Turbidity Meter ITM-3 SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-3 ITM-3G FOOD Relative Turbidity Meter ITM-3 Application / Specified Usage Media with a turbidity > 2000 NTU / 500 EBC (equal to about 5.5 % of display

More information

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application: SI-02 Electromagnetic Flowmeter for General Applications Description: Features / Universally applicable / Separate or compact measuring transmitter / Variety of lining material / DN15 to DN2000 / DIN-

More information

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

Microlectra bv. Capacitive level meter CLM 36

Microlectra bv. Capacitive level meter CLM 36 www.microlectra.nl průmyslová elektronika Capacitive level meter CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs,

More information

TUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS

TUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS TUFFY T3 Side Mounting Level Controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact

More information

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications Technical Datasheet Pressure Switch Models: CS2 & CS4 Key Features Compact and rugged design. Stainless steel weatherproof enclosure IP66 / NEMA 4X Hermetically sealed SPDT or microswitch ATEX / IECEx

More information

Micro Motion LNG Series Meters

Micro Motion LNG Series Meters Product Data Sheet PS-002079, Rev B February 2018 Micro Motion LNG Series Meters Global industry standard for liquefied natural gas metering A complete, dedicated Coriolis meter solution for LNG dispensing

More information

Type Type 2000 Transducers. I/P & E/P Transducers

Type Type 2000 Transducers. I/P & E/P Transducers Type 2000 I/P & E/P Description Principle of Operation The Type 2000 I/P and E/P transducers utilize closed-loop pressure feedback-control for precision pressure output and minimized effects of temperature,

More information

InTrac Series versatile retractable housings: When process safety is crucial! INGOLD Leading Process Analytics

InTrac Series versatile retractable housings: When process safety is crucial! INGOLD Leading Process Analytics INGOLD Leading Process Analytics Enhanced process safety with TRI-LOCK TM Reduction in overall process costs Broad-based electrode / sensor program Flexibility in process adaption InTrac Series versatile

More information

LIQUID METER TYPE FMO

LIQUID METER TYPE FMO LIQUID METER TYPE FMO INNOVATORS IN FLOW TECHNOLOGY FLUX LIQUID METER TYPE FMO OVAL ROTOR DESIGN FLUX liquid meters type FMO are positive displacement flowmeters according to the oval rotor design. They

More information

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / /

MICROSTAT-M. Page 1/7. Data Sheet Type /2160. Type / / 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 Harlow - Essex CM2 2DY, UK Data Sheet 6851 Page 1/7 MICROSTAT-M Particularities Electromechanical temperature

More information

M7100 Pressure Transducer

M7100 Pressure Transducer Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces Medium to high

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 1 Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Authorizations Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase separation

More information

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

SPRING LOADED THERMOCOUPLE CONFIGURATIONS SPRING LOADED THERMOCOUPLE CONFIGURATIONS FOR USE WITH THERMOWELLS II 3G Ex na/nl TCRN/WN/TN S30 S31 S36-1 S36-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration guarantees

More information

POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE

POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE The manufacturer guarantees only English text. Available on our web site: www.isomag.eu INDEX TECHNICAL DATA... 3 OVERALL FEATURES...

More information

Relative Turbidity Meter ITM-51

Relative Turbidity Meter ITM-51 SENSORS FOR FOOD ND BIOPHRM. Product Information ITM-51 ITM-51R FOOD Relative Turbidity Meter ITM-51 pplication / Specified Usage Relative turbidity measurement of liquid media for mid to high turbidity

More information

Standard Parts. Ganter. Highlights Standard Parts in Hygienic Design

Standard Parts. Ganter. Highlights Standard Parts in Hygienic Design Standard Parts. Ganter. Highlights Standard Parts in Standard Parts in Maximum hygiene is a fundamental requirement, not only where food is produced. Hygiene also plays an increasing role in other industrial

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

QGO Oxygen Sensor. Building Technologies HVAC Products

QGO Oxygen Sensor. Building Technologies HVAC Products 7 842 QGO20.000D17 QGO20.000D27 Oxygen Sensor QGO20.000... The QGO20... is an oxygen sensor designed for acquiring the residual oxygen content of flue gases in heat generation plant burning natural gas

More information

M7100 Pressure Transducer

M7100 Pressure Transducer Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces Medium to high

More information

Flow measurement of Liquids and Gases

Flow measurement of Liquids and Gases Flow measurement of Liquids and Gases Metallic construction Operates horizontally or vertically DN 40 to DN 500 Flow rate: - Water: 0.8 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 24000 Nm 3 /h.

More information

Supporting bracket. Cooling fins. Internal reflector. Shock-resistant tempered glass. Ex e terminal housing for a quick connection

Supporting bracket. Cooling fins. Internal reflector. Shock-resistant tempered glass. Ex e terminal housing for a quick connection EVL - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps of up to 400W - Saves in energy, maintenance and installation costs - Instant, bright illumination - Suitable for GAS category IIC Supporting

More information

Liquid level switch BW 17

Liquid level switch BW 17 KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han

More information

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier of temperature sensors and component parts for all industrial applications Manufactured

More information

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual P/N 1000006053 Rev E $7%$QDO\WLFV// //& 733 Dairy Rd. Parkton, Md. 21120 www.atbanalytics.com (410) 733-6365 Table of Contents Chapter 1: Getting

More information

Level sensor With reed-chain technology Model FLR

Level sensor With reed-chain technology Model FLR Level measurement Level sensor With reed-chain technology Model FLR KSR data sheet FLR Applications Level measurement for almost all liquid media Chemical, petrochemical, natural gas, off shore, shipbuilding,

More information

Supply Voltage 10-30V DC V AC V DC/ VAC 10-30V DC VAC V DC/ VAC. (Pico-style) V DC/ (Micro-style) 10-30V DC

Supply Voltage 10-30V DC V AC V DC/ VAC 10-30V DC VAC V DC/ VAC. (Pico-style) V DC/ (Micro-style) 10-30V DC Convergent Mode(Sensing =6,Infrared Light) Connection Supply Voltage Output Mode Part Number m or 9m Cable MPC6DCX9C4U (m) MPC6DCX9C4U9 (9m) MPC6DCX9C4UHS (m) MPC6DCX9C4U9HS (9m) (4ms on/off) (wire) MPC6ACX9CU

More information

High Temperature Pressure Sensor

High Temperature Pressure Sensor Pressure High Temperature Pressure Sensor for Gas Turbine- and Thermoacoustics Applications Differential, acceleration compensated, piezoelectric pressure sensor for operation temperatures up to 700 C.

More information

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Pressure Booster System. Hya-Eco VP. Type Series Booklet Pressure Booster System Hya-Eco VP Type Series Booklet Legal information/copyright Type Series Booklet Hya-Eco VP KSB Aktiengesellschaft Frankenthal All rights reserved. Contents provided herein must neither

More information

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures BPG 42 The BPG range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

ALPHAIR PNEUMATIC ACTUATORS 120 Y SERIES X SERIES

ALPHAIR PNEUMATIC ACTUATORS 120 Y SERIES X SERIES ALPHAIR PNEUMATIC ACTUATORS Y SERIES - 18 X SERIES ALPHAIR AP-Y () AND AP-X (18) SERIES pneumatic actuators are made by the best manufacture experience on design, material, machining, assembly. The internal

More information

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting Ed.17.02 Design Type Case diameter in stainless steel for mounting in thermowell or for direct mounting F73 Dim 100 mm or 160 mm Accuracy Class 1,0% DIN EN 13190 Case Glass Stainless steel with bayonet

More information

Bypass Level Indicator / Functional description

Bypass Level Indicator / Functional description Bypass Level Indicator / Functional description Functional description Bypass level indicators form an integral part of the pressure vessel. Via two process connections a standpipe ( bypass ) is mounted

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

Miniature I/P, E/P Transducer

Miniature I/P, E/P Transducer Miniature I/P, E/P Transducer Accurate and economical electronic pressure control The Type 550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional

More information

Bushing diameter 16 mm, 19 mm or 22 mm. Easy to clean metal surface. Very long life expectancy. Ring or dot illumination. ➀ One-piece bushing

Bushing diameter 16 mm, 19 mm or 22 mm. Easy to clean metal surface. Very long life expectancy. Ring or dot illumination. ➀ One-piece bushing Piezo switches Specifications Bushing diameter 6 mm, 9 mm or 22 mm UG40--R3 Sealed to IP68 and IP69K (switches mounted on panel) Easy to clean metal surface Very long life expectancy Ring or dot illumination

More information

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination SLED Painted aluminium body and cover - Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination Tempered glass Ex e terminal board housing for fast connection Mounting

More information

Preparation and Installation of the ENVIRO-SEAL I Rupture Disc

Preparation and Installation of the ENVIRO-SEAL I Rupture Disc Preparation and Installation of the ENVIRO-SEAL I Rupture Disc GEP-6019 Rev. AA 102335 Ref. I.D.: 10711 WARNING USER SHOULD READ AND THOROUGHLY UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING RUPTURE DISC.

More information

ALPHAIR PNEUMATIC ACTUATORS

ALPHAIR PNEUMATIC ACTUATORS September 201 ALPHAIR PNEUMATIC ACTUATORS 90 - I Series 120 - Y Series 180 - X Series ALPHAIR pneumatic actuators are made by the best manufacture experience on design, material, machining, assembly. The

More information

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE C20 C21 C26-2 C26-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration

More information

SAMSON LIQUID RING VACUUM PUMPS. 33 mbar absolute to 1013 mbar absolute. DATASHEET ME-SERIES DOC1005A

SAMSON LIQUID RING VACUUM PUMPS. 33 mbar absolute to 1013 mbar absolute. DATASHEET ME-SERIES DOC1005A TRUCKS FOOD OFFSHORE FISH PROCESS DATASHEET ME-SERIES DOC1005A ME-SERIES Range: 33 mbar absolute to 1013 mbar absolute. Capacity: From 50 m3/h to 165 m3/h Index Page About SAMSON PUMPS...4 Materials...5

More information

WLC60 Heavy Duty LED Light

WLC60 Heavy Duty LED Light Datasheet Banner's WLC60 Heavy Duty Lights are engineered to withstand harsh environments, making it the first choice for a machine lighting solution. A conservative mechanical design protects against

More information

Transmitters for general requirements SITRANS P DS III

Transmitters for general requirements SITRANS P DS III Siemens AG 0 Technical specifications SITRANS P, DS III Input Measured variable Spans (infinitely adjustable) or nominal measuring range and max. permissible operating pressure Lower measuring limit Measuring

More information

Omnicomm LLS 4 Fuel Level Sensors

Omnicomm LLS 4 Fuel Level Sensors Omnicomm LLS 4 Fuel Level Sensors User Manual 23.03.2018 Contents 3 4 5 5 7 General Specifications Preparation Fuel Tank Preparation Sensor Preparation 8 10 11 Setting Empty/Full Calibration Omnicomm LLS

More information

SPECIFICATION OPTICAL TERMINATION PANEL

SPECIFICATION OPTICAL TERMINATION PANEL SPECIFICATION OPTICAL TERMINATION PANEL Model Spec. No. VSOF-OTP-H VSS-0809-OTP-H-01A/SD Quality Assurance Team Distribution Depts. Manufacturing Division Sales Division Management Division Revision 09.

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The MAG is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. Benefits Wide range of sizes: DN 15 to DN 2000 (½ to 78 ) The flexible design

More information

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors Standards Certification 94/9/EC (ATEX) Directive According to European Standards EN 60079-0 EN 60079-1 EN 61241-0 EN 61241-1 Protection degeree IP66/67

More information

Memosens CPS76D. Technical Information

Memosens CPS76D. Technical Information Technical Information Memosens CPS76D Combination of ph and ORP electrode with Memosens technology For process technology, hygienic and sterile applications Resistent to poisoning reference with ion trap

More information

VSM/55600/N2, Hollow piston rod cylinder Magnetic piston, double acting

VSM/55600/N2, Hollow piston rod cylinder Magnetic piston, double acting VSM/55600/N, Hollow piston rod cylinder > > Ø 5 and 0 mmm > > Ideally suited for vacuum selected liquid transfer applications through the piston rod > > Non-rotating and telescopic piston rod provides

More information

Measuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600

Measuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600 Bypass Level Indicators ATEX or GL Approval measuring monitoring analysing NBK -ATEX,-GL -03, -06, -07, -10 Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart Pressure: max.

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information