PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) REV: 4/11

Similar documents
G.R.G. (GLASSFIBRE REINFORCED GYPSUM) (For Interior Systems)

SECTION GLASS FIBER REINFORCED GYPSUM FABRICATIONS

09/07/07 GLASSFIBER REINFORCED GYPSUM (GRG) C. S. I Spec Master Spec Page 1

Showcase Your Space. Not Your Access Panel. Product Features. Shop online at or call

First Class Building Products, Inc.

First Class Building Products, Inc.

Gold Bond BRAND Gypsum Sheathing

***************************************************************** ** NOTE TO SPECIFIER **

FRP Classic TM Cast Stone Fiberglass Fabrications Architectural Specification

Nudo Guide Specification 03/01/2016 FiberScore FRP Wall Panels SECTION FIBERSCORE FIBERGLASS REINFORCED WALL PANELS

PRODUCT SPECIFICATIONS

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Foil Back Gypsum Board

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED

SECTION Fiber Reinforced Stucco 1

Decorative Fiberglass Reinforced Wall Panels

A. Prepare formwork shop drawings using qualified professional engineer. Include detail of fabrication, assembly, and support of formwork.

Phenolic Exterior Wall Cladding

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

ENGINEERING SPECIFICATION PULTRUDED DYNADECK INTERLOCKING FLOORING

SECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

SECTION GYPSUM BOARD

FRP Baffle Wall Standard Specification-Section 11350

FRP Floor Panels Standard Specification

High Flex Gypsum Board

ARCHITECTURAL SPECIFICATION

Marlite Guide Specification 2/24/2017 Surface Systems - MAP375 System SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

Section GYPSUM DRYWALL

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION GYPSUM BOARD ASSEMBLIES

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION EXPANSION CONTROL

ThermalShell Modular Insulated Pre-Cast Panels

A. ASTM C635, Standard Specifications for Metal Suspension Systems. B. ASTM C636, Recommended Practice for Installation of Metal Suspension System

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

SECTION Paper-Composite Countertops PART 1: GENERAL

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Expansion Joint Covers

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION ARCHITECTURAL FIBERGLASS

RAY-CORE Structural Insulated Roof and Wall Panels

SECTION ARCHITECTURAL FIBERGLASS

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. March 16,

SECTION EXPANSION CONTROL

SECTION CEMENTITIOUS SHEATHING

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

SECTION EXPANSION CONTROL

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Framed Decorative Panel Systems

Expansion Joint Covers (079513)

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL

SECTION GYPSUM BOARD

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

A. Stonewood: Solid phenolic panels for interior wall cladding of commercial and institutional buildings.

SECTION GYPSUM BOARD ASSEMBLIES

SECTION FIBER REINFORCED CEMENTITIOUS PANEL CLADDING

Submittal Transmittal

ENGINEERING SPECIFICATION NON-MAGNETIC RAISED FLOOR SYSTEM FOR MRI ROOM APPLICATIONS

SECTION SOUND CONTROL DOORS

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

SECTION GYPSUM BOARD

COMPOSITESIDING

SECTION ACOUSTICAL PLASTER CEILINGS

SECTION GYPSUM BOARD PART 1 - GENERAL

Interior Extreme AR. Gypsum Panels. Gold Bond BRAND

SECTION NON-LOAD BEARING WALL FRAMING. B. Section Furring and Lathing: Lath and furring for interior plaster applications.

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

SECTION GYPSUM BOARD

SECTION ROUGH CARPENTRY. B. AWPA (American Wood Preservers Association) Book of Standards. C. WCLIB (West Coast Lumber Inspection Bureau)

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

Ceiling Tiles C200B - Specification

SECTION ACOUSTICAL PLASTER CEILINGS

ENKASONIC FLOOR UNDERLAYMENT 9110

High Strength LITE Gypsum Board

XP Gypsum Board Regular, Fire-Shield Type X and Fire-Shield Type C

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

SECTION PLATE CONNECTED WOOD TRUSSES

EDON CORPORATION 1160 Easton Rd. Horsham, PA tel. (215) or fax. (215) edon.com

Use it for interior wall and ceiling applications and in areas with limited water exposure.

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

Polycrete Big Block Standard Specification

SECTION (09265) - GYPSUM BOARD SHAFT WALL ASSEMBLIES

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION GYPSUM BOARD ASSEMBLIES

SECTION ACOUSTICAL PLASTER CEILINGS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

AMBICO Limited Section and BLAST RESISTANT STEEL WINDOW FRAME ASSEMBLIES Page 1

PRODUCT SPECIFICATIONS PULTRUDED GRATING AND TREADS SECTION PART 1 GENERAL

SECTION / / BULLET RESISTANT SOUND CONTROL WINDOWS

SECTION STRUCTURAL INSULATED PANELS

Transcription:

Plasterform Inc. 1180 Lakeshore Road East, Mississauga, Ontario Canada L5E 1E9 t 905.891.9500 1.800.268.4534 f 905.891.2232 plasterform.com SECTION 09285 PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) REV: 4/11 1 GENERAL 1.1 SECTION INCLUDES.1 Furnish all materials, labor, equipment and services necessary for the supply and installation of Plasterform GRG components as indicated on the drawings and contract documents, all in compliance with local codes and/or ordinances..2 Work shall include supply of GRG components, installation, and joint treatment. 1.2 RELATED SECTIONS.1 Section 09100 : Metal Support Systems.2 Section 09250 : Gypsum Board.3 Section 09900 : Painting 1.3 INTENT.1 This specification is intended to generally outline the Plasterform GRG requirements, as they pertain to the overall project design. In all cases, the Manufacturer s printed specifications shall govern the work of this section. 1.4 RESPONSIBILITY.1 The Gypsum Board Contractor shall install and tape the work under this section and he will be responsible for co-ordinating the installation with drywall work and other trades. 1.5 SUBMITTALS.1 Submit a minimum of 3-8" x 8" Plasterform GRG flat samples to the Finishing Contractor for paint selection..2 Submit shop drawings for approval showing plans, sections, details, joint treatment, reinforcing, fastening devices and the relation of the Plasterform GRG components to the surrounding construction.

PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) 2 1.6 MOCK-UP.1 Prior to production erect one prototype on-site or at the Plasterform plant, for review by the Architect. 1.7 SUBSTITUTIONS.1 Manufacturers desiring to submit proposals other than Plasterform shall, at least 10 days prior to the bid date, submit to the Architect all descriptive information of the system. These Manufacturers must have a minimum of five years experience with the system and provide photographs and shop drawings of at least three projects similar in detail and scope with names, addresses and phone contacts of the respective Architects and Installation Contractors. Independent test data showing compliance with the specified system and three samples of similar details must also be submitted. 2 PRODUCTS 2.1 MANUFACTURER.1 Plasterform Inc. 1180 Lakeshore Road East Mississauga, Ontario Canada L5E 1E9 Tel: 905.891.9500 or 1.800.268.4534 Fax: 905.891.2232 2.2 MATERIALS.1 Plasterform GRG components shall be prefabricated with high density gypsum, free of resin and asbestos, reinforced with chopped strand fiber..2 Plasterform GRG components shall be reinforced with steel or wood..3 No additives such as retardents, accelerators or polymers are permitted..4 Fabrication will be as per approved shop drawings and will not include assembly. If multiple components are required to complete design criteria as per contract drawings, additional site work under related section, installation or finishing may be required..5 Plasterform GRG components shall be ready to receive primer and paint as specified under Section 09900.

PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) 3 2.3 TOLERANCES (FABRICATION) Dimensional - all directions +/- 1/8" Thickness - skin +/- 1/16" Thickness - total until 1/8" - 3/16" Warpage or Bowing +/- 1/16"/foot Site conditions and normal manufacturing variations may require additional site work to maintain these tolerances. 2.4 PHYSICAL PROPERTIES Shell Thickness 3/16" Weight (depending on reinforcing) 2-3 lbs/sq.ft Density 103-112 lbs/cu.ft Flexural Strength (ASTM C-947-89 MOD.) 4,820 p.s.i. Compressive Strength (ASTM C-472-90 MOD.) 13,800 p.s.i. Modulus of Elasticity - In flexure (ASTM C-947-89 MOD.) 3.38 x 10 6 p.s.i. Tensile Strength (ASTM D-638-94 b MOD.) 1,810 p.s.i. Impact Strength (ASTM D-256 notched) 3.26 ft.lb/ in. of notch Impact Strength (ASTM D-256 unnotched) 8.0 ft.lb/ in 2. Hardness Barcol (ASTM D-2583-93) 54 Fiber Content 5-6% by weight Humidified Deflection (ASTM C-473-95) 1/32 deflection/in. Coefficient of Expansion (ASTM D-696-91) 0.98 x 10-5 in./in./ F Fuel Contribution (ASTM E-136-98a) 0 Flame Spread (ASTM E-84-94) 0, Class A Smoke Index (ASTM E-84-94) 0, Class A Fastener Withdrawal - drywall screw embedded in wood 329 lbs - drywall screw embedded in steel 764 lbs - steel cable embedded in steel insert 1,050 lbs 2.5 INSPECTION The Architect or his representative shall have access to the manufacturing facilities, either prior to contract award or thereafter, to inspect or verify compliance with the above specifications.

PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) 4 3.0 EXECUTION 3.1 PRE-INSTALLATION RESPONSIBILITY.1 Field Measurements: Prior to manufacturing, the Installer will be responsible for obtaining all field dimensions for inclusion on the Manufacturer s shop drawings..2 Co-Ordination: The Installer will be responsible for the co-ordination of the installation with related sections, within the tolerances specified in the respective articles..3 Discrepancies: Prior to installation, the Installer shall check job site dimensions and conditions. Any discrepancies between design and field dimensions shall be brought to the attention of the General Contractor and the Architect. 3.2 DELIVERY, STORAGE, HANDLING AND PROTECTION.1 Transport and handle units in a manner that avoids excessive stresses or damage..2 Components displaying obvious damage must be rejected at site at time of delivery..3 Store the components in a controlled environment weather protected, on level surfaces, with temporary supports as required. Do not stack or lean. 3.3 INSTALLATION.1 Components shall be lifted with suitable devices..2 Components shall be installed plum and true. Shim where necessary..3 Fasten components with self drilling, self tapping bugle head screws through face or back as indicated on shop drawings..4 Where components are suspended, use as a minimum 12 gauge galvanized steel wire and the suspension points indicated on the shop drawings..5 Framing, hangers. etc, as specified for Gypsum Board..6 Butt joints are to be adhered together using Liquid Nail or equivalent. 3.4 JOINT FINISHING, PATCHING AND CONTROL JOINTS.1 Tape, fill and sand all joints and introduce control joints (+/- 35' - 0" O.C) as required under Section 09250 of the Specifications and as outlined in U.S.G. or C.G.C. Gypsum Construction Handbook..2 Patch countersunk fasteners and any damage to match component texture.

PLASTERFORM GLASSFIBER REINFORCED GYPSUM (GRG) 5 3.5 FINISHING.1 Refer to Painting Section of the Specifications..2 The Paint Contractor shall comply with ASTM C 840-79 Specifications. NOTES 1. Plasterform GRG components shall be used for Interior Applications only. 2. Unfinished GRG may exhibit slight imperfections, normally hidden by textured or mat finishes. To obtain satisfactory results with Gloss Finishes, additional filling, sanding, priming and painting may be required. 3. Improper sealing, more than crowning, can cause tape joint read-through after painting. This is due to the difference in porosity between joint compounds and GRG therefore, ensure that the Painting Contractor seals all surfaces properly prior to finishing. REV: 4/11