FACT SHEET Standard: Fall Protection

Similar documents
How to Perform a Rooftop Safety Audit

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

WORKING AT HEIGHT PROCEDURE

Effective Date: 14-March Table of Contents

Fall Protection Program For Working on Flat Roofs

DUQUESNE UNIVERSITY SAFETY PROGRAM FOR WORKING AT ELEVATED HEIGHTS

Reliant Holdings Ltd Safety Management System

SECTION PORTABLE RAILING SYSTEM

Scaffolds. OSHA Office of Training & Education 1

Scaffolds. OSHA Office of Training & Education 1

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

Walking and Working Surfaces. Slips and falls on walking surfaces constitute the majority of general industry accidents

BURBANK FIRE DEPARTMENT 311 East Orange Grove Avenue, Burbank CA Fax

In addition to standard plan requirements, all plans submitted for PV installation shall include the following details:

STANDARD PRACTICE INSTRUCTION

Scaffolding Procedures

AN OVERVIEW OF THE NEW MIOSHA WALKING-WORKING SURFACES STANDARD

Building 67 Roof Safety Assessment

Guidelines for Solar Photovoltaic Installation

Guideline for Fire Safety. Elements of Solar. Photovoltaic Systems

Safety Documents > Safety Manual > Scaffolds

DIVISION 07 - THERMAL & MOISTURE PROTECTION

A REAL-WORLD VIEW: IMPLEMENTING NEW OSHA FALL PROTECTION REGULATIONS

CONSTRUCTION ENVIRONMENTAL HEALTH & SAFETY EXHIBIT FALL PREVENTION AND PROTECTION

Management Plan for Walking/Working Surfaces & Fall Protection (29 CFR , 23, 66 App.C; 29 CFR ) ISD #535

Signage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection:

Section X - Miscellaneous

CITY OF LA MESA FIRE DEPARTMENT SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE

Section 32 - Miscellaneous

Section 4 CONVENTIONAL FALL PROTECTION

SECTION GROUND WATER STORAGE TANKS

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

MARBLEHEAD FIRE DEPARTMENT Standard Operating Guideline Draft for Photovoltaic/Solar Installations

SECTION MISCELLANEOUS METALS

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005 SECTION WALKING/WORKING SURFACE AND FALL PROTECTION

WORKING AT ELEVATED PLACES Working on Roofs

Building 39 Roof Safety Assessment

SCAFFOLDING PROCEDURE

SECTION STRUCTURE MOUNT RAILING SYSTEM

SECTION HORIZONTAL FALL PROTECTION RAIL

Scaffolding Safety Procedures

SECTION 20 WALKING-WORKING SURFACES

UNITED INDUSTRIES GROUP INC.

Savard Labor & Marine Staffing, Inc. Fall Prevention Program Rev3/14

Issue no: 10 Date: March Operation and Maintenance Manual Access Technologies Limited All rights reserved. 1 of 20

Excavation Safety Program

LFP ROOFGUARD LIFTSAFE FALL PROTECTION INC. -

SECTION SOUND CONTROL DOORS

Scissor Lift Safety. Supervisor Manual 29 CFR , 451, 452, 454. Page 0

Fall Protection Manual (EHS Program Manual 7.9)

19 Remove Barriers to Solar Energy

Building 17 Roof Safety Assessment. Not Applicable - No fall restraint system. Within handrailed and marked painted areas NA

PART I TB TOOLS #9-11:

E3937. Leader s Guide

Building 18 Roof Safety Assessment

Approved By: R. Keen Date: March 6, 2014 Rev. No Scaffolding Procedure

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

Building 40 Roof Safety Assessment

Elevated Work Safety Meeting

City of Santa Monica. Building and Safety Division. Structural Criteria for Residential Rooftop Solar Energy Installations

SEPARATING PEOPLE FROM HAZARDS. Rooftop Safety Audit

XSPHILOSOPHY: DRIVEN BY INNOVATION

Limited th ave Maple Ridge, BC V4R 2H4 (778) 240-WRAP (9727)

Office of the Fire Commissioner Building and Fire Safety Section

Fixed Mounted Guardrails with Bracket Mounts

Santa Monica Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

A. ANSI A10.32, "Personal Fall Protection Used in Construction and Demolition Operations."

Beverly Hills Fire Department SOLAR PHOTOVOLTAIC INSTALLATION GUIDELINE 2008 TABLE OF CONTENTS

RESIDENTIAL ARCHITECTURAL DESIGN (RAD) REVIEW STANDARDS AND PROCESS

Copyright Materials. Building Envelope Consulting and Scientists, LLC 2017

EXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS

Scaffolding Safety. Scaffolding

OCCUPATIONAL HEALTH AND SAFETY ACT SCAFFOLDING REGULATIONS

Streamline Solar Photovoltaic Structural Criteria for Residential Rooftop Solar Energy Installations (Streamline Solar Form 5)

WORKING AT HEIGHT. The company will comply with the Work at Height Regulations 2005, its schedules and Codes of Practice.

Facility Improvements

Building 233 Roof Safety Assessment

OSH5063EP(PRS3607) Workplace and Work Equipment Hazard. Session 9. Working at Height

PRESCRIPTIVE COMPLIANCE METHOD

Structural Criteria for Residential Rooftop Solar Energy Installations

SECTION / STC 52 METAL SOUND CONTROL DOORS

SECTION SUSPENDED MAINTENANCE ANCHORAGE SYSTEM

Structural Criteria for Residential Rooftop Solar Energy Installations

Bleacher Safety Guidelines

Eave Barriers. Railings required by these Orders, except as otherwise provided, shall conform to the following standards:

3T - Through The Trapdoor Method

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

REROOFING ANALYSIS OF K-12 BUILDING. Unified School District 306 Gypsum, Kansas

Tatum Ranch Community Association Guidelines for Installation of Solar Energy Devices

ATTACHMENT 50-1: PERFORMANCE AND MEASUREMENT TABLE

TEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS. Combisafe International AB

Repair Maintenance Hangar Phase II August 2010 SECTION LIGHTNING PROTECTION SYSTEM PART 1 GENERAL

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

Bleacher Safety. (c) Excessive guardrail space: e.g., between the bottom rail and the mid-rail (four inches or less).

SCAFFOLDS Revision No: 3

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 7

UPRR INDUSTRIAL LEAD BRIDGE T-WALL RETAINING WALL SYSTEM 5.0 x 7.5 UNITS DESIGN UNIT 018 WORK PACKAGE 04

INTRODUCTION. Inspection Procedures oinitial Inspection Report. Visual Inspection Physical Sampling (Core and Slit Samples)

DOCK CONSTRUCTION GUIDE

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

Transcription:

ROOFTOP FALL PROTECTION GUIDANCE EH&S acknowledges the varied nature of work on roofs, uncertain frequency of exposure, wide range of potentially hazardous conditions, and the confusion among trades groups, service providers, and building owners and managers on classifying activity and choosing appropriate fall protection alternatives. In order to enhance safe work practices, EH&S is recommending the following guideline on rooftop fall protection: New Construction Flat, Low Sloped Roofs In the design phase for new buildings, identify mechanicals that do not require specific rooftop placement and locate at least 15 feet from the leading edge. If mechanicals are required on the rooftop or above occupied levels, design to house critical equipment within rooftop penthouse enclosures. If mechanicals are required on the rooftop or above occupied levels and cannot be housed within rooftop (penthouse) enclosures, surround equipment with a conforming parapet wall or standard railing. On roofs with mechanicals, rated /fixed anchor point systems may be installed as a supplement to conforming parapet wall or standard railing to provide fall protection for miscellaneous activities (window washing, snow and ice removal, drain cleaning, etc.) On roofs without mechanicals, rated /fixed anchor point systems may be installed providing fall protection for miscellaneous activities (window washing, snow and ice removal, drain cleaning, etc.) Revision Date: 6/1/2015 Page 1 of 6

Existing Buildings - Flat, Low Sloped Roofs with mechanicals not currently protected by standard railing or conforming parapet. Implement administrative controls: Lock all access doors or other points to the roof, and post standard Harvard signs stating that roof access is not allowed unless authorized by the Building Manager. If possible, install standard railings (passive) around the entire perimeter of the roof. If installing standard railings for the entire roof is not possible, then establish warning lines as described above to mark the pathway to and around any work area greater than 15 feet from leading edge and install standard railings around equipment less than 15 feet from the leading edge. Personnel on roof are not permitted to cross the warning line or railings. Fixed anchor point systems may be installed as a supplement to conforming parapet walls or standard railings to fall protection for miscellaneous activities (window washing, snow and ice removal, drain cleaning, etc.) If standard railings or warning lines cannot be installed due to restrictions (historic commission, etc.), then install hardware permitting the use of safety harnesses (active fall protection - anchor points, horizontal lifelines, etc.). Existing Buildings - Flat, Low Sloped Roofs without mechanicals not currently protected by standard railing or conforming parapet. On roofs without mechanicals, rated /fixed anchor point systems may be installed providing fall protection for miscellaneous activities (window washing, snow and ice removal, drain cleaning, etc.) Revision Date: 7/6/2015 Page 2 of 6

Diagrams below demonstrate how different fall protection elements and strategies may be implemented: Warning Line Railing Fixed Ladder Anchor Point DIAGRAM 1 Access door and < 15 feet from leading roof edge Stair DIAGRAM 2 Fixed ladder roof access < 15 feet from leading roof edge; All units > 15 feet from leading roof edge Revision Date: 7/6/2015 Page 3 of 6

DIAGRAM 3 Access hatch All hatches must be protected by guardrail Upright solar panels > 42 inches. Provides adequate fall protection All unrated skylights must be protected by rail or rated screens Upright solar panel bank > 42 inches Hatch Sky light Upright solar panel bank > 42 inches DIAGRAM 4 Access door and < 15 feet from leading roof edge Non-conforming parapet < 36 inches requires rail or anchor points Penthouse Revision Date: 7/6/2015 Page 4 of 6

DIAGRAM 5 Access hatch All hatches must be protected by guardrail Warning line to anchor point Anchor point at 15 feet to leading edge Hatch Critical Point to Remember: Lock all access doors or other points of access to the roof and post standard Harvard fall protection warning signs. If possible, install standard railings (passive fall protection) around the entire perimeter of the roof. If installing standard railings for the entire roof is not possible, establish warning lines to mark the pathway to and around any work area greater than 15 feet from leading edge and install standard railings around equipment less than 15 feet from the leading edge. If standard railings or warning lines cannot be installed due to restrictions (historic commission, etc.), then install hardware permitting the use of safety harnesses (anchor points, horizontal lifelines, etc.). These systems may be installed as a supplement to conforming parapet walls or standard railings for miscellaneous activities Revision Date: 7/6/2015 Page 5 of 6

INSPECTION REQUIREMENTS Rated /Fixed Anchor Point Systems: Systems must be certified before being placed into service/ initial use and shall be detail the rated load capacity and initial certification by the manufacturer; System must be visually inspected by authorized person before use each and cannot be used if any defects are present. System must be inspected by a competent person at intervals specified by the manufacturer/supplier, but not exceeding 12 months; System must be re-certified by or under supervision of registered Professional Engineer (PE) when replacing roof or at periods not to exceed 10 years; All inspections and certifications must be documented in a dedicated log book and retained by the Building Manager. Railings: Railing should be inspected on a periodic basis for signs of deterioration and or damage. Damaged rails are to be clearly marked and promptly repaired. Wooden and speed railing should be inspected annually If you have additional questions please contact your local EH&S Safety Officer. Revision Date: 7/6/2015 Page 6 of 6