Application of chlorine dioxide for secondary effluent polishing

Similar documents
Microbial Removal Efficiency of UV in Tehran Shahid Mahallati Wastewater Treatment Plant

A Method to Determine Biodegradable Dissolved Organic Nitrogen in Water ND 58108, USA

UV DISINFECTION OF LOW TRANSMITTANCE PHARMACEUTICAL WASTEWATER

Operation of a small scale MBR system for wastewater reuse

TREATMENT OF HOSPITAL WASTEWATER USING ACTIVATED SLUDGE COMBINED WITH BIOLOGICAL CONTACTOR

Scavenger2000 s Technology

Effects of wastewater stabilization pond effluent on agricultural crops

What is Chlorine Dioxide and Why You Should Learn About It Now?

Unit 6. The current wastewater treatment systems in Gaza Strip

Field experience by water treatment facilities of Chlorine Dioxide & Chlorine Compound Disinfectant, replacing the traditional chlorine treatment

Wastewater treatment objecives

KEYWORDS: Adsorption, Chromium(VI), COD, Tannery Effluent, Banyan Sawdust.

Enhancing Environmental Monitoring Using Total Organic Carbon (TOC)

International Journal of Science, Environment and Technology, Vol. 4, No 5, 2015,

Effects of Environmental Factors on Nitrification Occurrence in Model Drinking Water Distribution Systems. Ng M.Y.

19. Rapid Disinfection Technique Using High- Concentration Ozone for Combined Sewer Overflow

Feasibility Study of Lime Addition Method for Biosolids Stabilization in West Ahwaz Wastewater Treatment Plant

Water sanitation at its best

Prepared by the Operation of Municipal Wastewater Treatment Plants Task Force of the Water Environment Federation

MEMBRANE BIO-REACTOR. Prashanth N 1 1. INTRODUCION

Treatability Study and Reverse Osmosis Pilot Study of Industrial Wastewater at a Wood Products Mill

Water Resources Director: Chris Graybeal

Department of Civil Engineering, IIT Delhi (India) CVL722 (Sem1, ) (Dr. Arun Kumar;

Algae Removal from a Facultative Lagoon System Using Dissolved Air Flotation. J. Patrick Pierce, P.E. Environmental Treatment Systems, Inc.

BEING GOOD STEWARDS: IMPROVING EFFLUENT QUALITY ON A BARRIER ISLAND. 1.0 Executive Summary

Control of Trihalomethanes (THM s) In Wastewater. Philip S. Bober, Operations Superintendent, Wayne Township

3 8 COLIFORM BACTERIA AS INDICATOR ORGANISMS Laboratory tests for disease-producing bacteria, viruses, and protozoa are difficult to perform

Wastewater Treatment. Where does wastewater go when it leaves your house?

Industrial Waste Water Treatment. Unit 5

REGULATION NO. 62 COLORADO DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT WATER QUALITY CONTROL COMMISSION REGULATIONS FOR EFFLUENT LIMITATIONS

QUALITY ASSESSMENT of WATER and WASTEWATER

AL-KAWTHER INDUSTRIES LTD

American Water College 2010

Module 5: Disinfection and Chlorination Answer Key

Voting Card on A Final Project

Complete. Compact. Compliant.

INNOVATIVE TECHNOLOGY TO IMPLEMENT A REUSE WATER PROGRAM. Stefan Haecker*, John Healy** 9311 College Parkway, Suite 1 Fort Myers Florida 33919

Wastewater Treatment Technology and Applications in Industrial Facilities

Water Treatment in Hotels and Resorts

Water Reuse: identifying the optimal solution for the desired water quality. Didier PERRIN Technical & Marketing Director Degremont Asia

A study on the starch and cellulose industries wastewater treatment by biological methods

City of Redlands Wastewater Treatment Plant. Redlands, CA LOCATION: Carollo Engineers; CH2M HILL MBR MANUFACTURER: COMMENTS:

CHEMNIUM NACLO SODIUM HYPOCHLORITE GENERATOR

Tour of Regional Water Reclamation Facility

PERFORMANCE EVALUATION OF 9 MLD SEWAGE TREATMENT PLANT AT GURGAON AND COST EFFECTIVE MEASURES IN TREATMENT PROCESS

Instructions. Disinfectants and Disinfection Byproducts Rule (DBPR) Monitoring Plan Template 6/4/03

WEFTEC.06. ** Hatch Mott McDonald Gateway View Plaza, 1600 West Carson Street Pittsburgh, Pennsylvania. *** City of Akron Akron, Ohio

Studying the Wastewater Parameters of Thermal Power Station

operation of continuous and batch reactors. Contrary to what happens in the batch reactor, the substrate (BOD) of the wastewater in the continuous rea

RESTRICTED URBAN REUSE OF KONYA (TURKEY) MUNICIPAL WASTEWATER TREATMENT PLANT EFFLUENTS VIA RECLAIMED WATER DISTRIBUTION SYSTEM

Characterization and assessment of Kullar Domestic Wastewater Treatment Plant wastewaters

Why Choose BacTerminator?

1. Introduction. 2. Scope of the Monitoring. 2.1 Stations and Parameters

Chlorination/Dechlorination: An Environmental Solution

Membrane Bioreactor vs. Extended Aeration Treatment Pilot Study Effluent and Groundwater Quality Presenter Leslie Dumas

Using PAA as an Alternative WWTP Disinfection Method

Membrane BioReactor: Technology for Waste Water Reclamation

APPENDIX R EPA GUIDELINES FOR WATER REUSE SUMMARY TABLES

TREATMENT OF DOMESTIC WASTEWATER USING BIOLOGICAL ACTIVATED SLUDGE METHOD

Treatment of grey water by using rotating Biological contactors unit

Canal water treatment with rapid sand filtration

SECTION 2.0 WASTEWATER TREATMENT PLANT AND DISPOSAL SYSTEM DESCRIPTION

CHAPTER 7 (Part 2) Water Processing

WATER TECH 2009 BANFF, ALBERTA, CANADA

Online Organics Monitoring for Rapid Process Control of Drinking Water and Wastewater Treatment Operations

GREYWATER CHARACTERIZATION IN SAUDI ARABIA. Control #: 117

Groundwater Replenishment with Purified Water Injection Provides Drought Protection & Environmental Benefits

Environmental Management System

Wastewater Treatment Works... The Basics

Civil Engineering Department

DW Module 23: Organic Removal Answer Key

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010

Water Treatment Solutions A - Z

WASTEWATER DEPARTMENT. Bentonville Wastewater Treatment Plant Facts:

TEXTILE INDUSTRY AND ENVIRONMENT. W.J.K.Dushyanthi Ranpatige Research Officer Industrial Technology Institute

Side by Side Piloting of Process Alternatives Yields Direct Performance Comparison

Lecture 7 Water Quality Monitoring: Estimation of fecal indicator bacteria

Total Coliforms and Turbidity Removal of Water in the Continuous Sand Filter

Potential Reuse of Grey water form Mosques for Toilet Flushing and Garden Irrigation in Saudi Arabia

Water Recycling and Reuse

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

Integrated Ozone Enhanced Biofiltration for Water Reuse

Session 311: Effects of TSS on Peracetic Acid Dosing for CSO Events

Chlorine Dioxide Feed System for Pre-Oxidation at an 8 MGD WTP

Chlorine Dioxide Feed System for Pre-Oxidation

UV Disinfection for a Municipal Wastewater Lagoon Effluent No Prior Filtration Needed? Wayne Wong, M.A.Sc., P.Eng., PMP

Phosphorous Removal using Tertiary UF How Low Can You Go? and Other Design Considerations

Zohul Hamza University of Basrah. Civil Engineering, Iraq

Water Governance Benchmarking Criteria

Membrane Bio-Reactors (MBRs) The Future of Wastewater Technology, Science and Economy Aspects

A New Development For (Textile Mill) Wastewater Treatment. Prepared for Publication in The American Dyestuff Reporter June 1988

An assessment of water withdrawal effect on water quality of the downstream river at the Mamloo Dam site using the QUAL2E model

A NEW METHOD FOR EVALUATING PRIMARY CLARIFIERS Alex Ekster and Cristina Pena San Jose/Santa Clara Water Pollution Control Plant City of San Jose

Performance of a Tire Chip Media Constructed Wetland Presented by William Li, PE, Stantec Consulting Inc Geoffrey Holmes, Superintendent, Fisherman

APPENDIX D SURFACE WATER TREATMENT

TREATMENT OF GROUND WATER BY USE OF CHLORINE DIOXIDE, CHLORINE AND MONOCHLORAMINE

CEL212 Environmental Engineering

Lecture 4 Water Quality Monitoring: Collection of water samples & estimation of physical parameters

At the Mercy of the Process Impacts of Nitrogen Removal Performance on WWTP Disinfection

Fundamental Concepts: Overview of Water Quality

Transcription:

International Journal of Environmental Science & Technology Vol. 1, No. 2, pp. 97-1, Summer 4 Application of chlorine dioxide for secondary effluent polishing * F. Vaezi, K. Naddafi, F. Karimi and M. Alimohammadi Department of Environmental Health Engineering, School of Public Health and Institute of Health Research Center, Tehran University of Medical Sciences, Tehran, Iran Abstract There are still many difficulties for developing the projects of using treated effluents. In this study, the efficiency of chlorine deoxide in the process of preparing the effluent of Sahebgharanieh Plant of Tehran for reuse purposes has been determind. Major results are as follows: Total COD reductions resulted from effluent treatment by ClO 2 solutions having concentrations equal to 1/4, 1/2 and 1/1 of COD samples at one hour contact time have been about 42%, 49% and 59% respectively. Total suspended solids were also reduced by treatment with ClO 2 solutions having the certain concentrations mentioned, and the reductions were about 37%,47% and 58% respectively. Besides total and fecal coliforms results indicated that ClO 2 apllied was quite efficient in effluent disinfection. The conclusion is that reasonable reductions would be expected in the amounts of remained major pollutants and so reuse applications for some non-potable purposes may become possible. The acidification of chlorite has been used for ClO 2 generation as it is better suited to small treatment systems. Key words: Wastewater treatment, chlorine dioxide, chemical oxidation, secondary effluent *Corresponding Author, E-mail: for_vaezi@yahoo.com Introduction Chlorine dioxide (ClO 2 ) which was first used in drinking water treatment is an oxidant increasingly of interest for industrial and wastewater treatment (Eckenfelder and Bowers, 1994). It has become a disinfectant alternative to chlorine and ozone because it offers the prospect of disinfection without the production of trihalomethanes and bromates so it is gaining acceptance as a water treatment promise (Otterholm and Jadesjo, ). As an oxidant, ClO 2 is generally considered for reuse strategies, because it is more effective than chlorine in inactivation of most pathogens (Metcalf and Eddy, 3). Besides, its biocidal properties are not influenced by ph and it is a more powerful oxidant than chlorine (Reynolds and Richards, 1996). However, the findings of Stanford group indicate that ClO 2 is only slightly superior to chlorine as a bactericide but it is a much superior virocide. Compared to ozone which is the strogest oxidant of the common disinfecting agents, ClO 2 has the advantages of easier generation in point of use and a longer life of the preservation (White, 1992). Interest in ClO 2 for chemical waste treatment is of more recent origin to reduce and eliminate the environmental problems caused by the discharge of waste streams without inadequate treatment (Eckenfelder and Bowers, 1994). In particular, oxidation offers one of the few methods for removing odor, color and various potentially toxic organic substances, often found in wastewaters (Jackman and Powell, 1991). ClO 2 is equally effective in secondary nonnitrified or nitrified effluents for disinfection purposes and the increased disinfection effectiveness seen in filtered versus nonfiltered wastewaters is not accompanied by any significant change in disinfectant demand (WPCF, 1986). In this article, we discuss the usefulness of ClO 2 as a disinfectant and chemical oxidant for secondary effluent polishing. ClO 2 production and so its use for wastewater treatment has not already been performed in Iran. Materials and Methods Generating chlorine dioxide There are several methods available for ClO 2 generation. For this study, direct acid system has been used because it was well studied for most small treatment systems (White, 1992). This method utilizes the reaction of a strong acid with sodium chlorite (NaClO 2 ). The following reaction which is most accepted for H 2 SO 4 is:

F. Vaezi, et al. ClO 2 + 5 H 2 SO 4 8 ClO 2 + 5 Na 2 SO 4 + 2 HCl + 4 H 2 O Figure 1 is a schematic diagram of the manual small generation system arranged for this study. It was also needed to apply a compressed air supply to transfer the generated ClO 2 gas to the final flask. This flask was put in an ice bath to preserve the strength of the prepared stock solution. Both sulfuric and chloridric acids which were used in the preliminary tests, showed favorable results and the concentration of ClO 2 solutions prepared was enough to use in wastwater treatment. The stock solution was then stored in a glassstoppered dark-colored bottle in a refrigarator. Figure 1: Manual feed equipment arrangment for generating ClO 2 1. aspirator flask 2. gas generating bottle (reaction vessel) 3. collecting bottle containing NaClO 2 solution (14g/l) 4. collecting bottle containing water for gas absorbsion 5. separatory funnel containing % H 2 SO 4 Methods of ClO 2 control As it was already mentioned, ClO 2 gas produced in direct acid system was absorbed in enough distilled water. The ClO 2 concentration thus, prepared can be determined by iodometric method as outlined in Standard Methods (APHA, 1995). However, yield determination can be done only when laboratory apparatus for determination of chlorite and chlorate ions are available, because for calculating ClO 2 yield by the following equation (Aieta and Hernandez, 1984), the concentrations of these ions should have to be known : [ClO 2 ] ClO 2 yield = [ClO 2 ] + [ClO 2 - ] +.88 [ClO 3 - ] Wastewater sample and characteristics The samples were collected from Sahebgharanieh Treatment Plant in Tehran. This Plant which is located in north part of Tehran is an extended aeration system having 2 aeration basins. The wastewater is treated with an average flow of 25 m 3 h -1. Characteristics of secondary effluent samples before and after treatment by ClO 2 solutions, were determined according to the procedures outlined in the Standard Methods. The tests were confined to the determination of total COD, soluble COD, total suspended solids (TSS), total and fecal coliforms which all are considered to be the most important pollutants remained in the secondary effluents of conventional plants which do not practice disinfection. The period of this experimental study was performed in Tehran from January to July 1. In this period, the Sahebgharanieh Plant was often unabled to produce effluent with BOD and TSS of less than mgl -1. Results Figure 2 shows the results of secondary effluent treatment in total COD reduction by ClO 2 in different contact times. In Figure 3, the efficiencies of COD removal by ClO 2 in different phs could be considered in one hour contact time and results of total and dissolved COD reduction by various amounts of ClO 2 solution can be seen in Figure 4. Although the disinfection effect of ClO 2 is a well known phenomena, the efficiency of the treatment in reduction of both total and fecal coliforms was determined. The results of this treatment in 6 minutes contact time with various concentrations of ClO 2 solutions are in Table 1. Finaly, Figure 5 shows the results of TSS removal by various amounts of ClO 2 solutions in one hour contact time. Table 1: Reduction of total and fecal coliforms by ClO 2 treatment of effluent samples mg/l ClO 2 applied * Contact time (min.) Total coliforms (MPN/ml) Fecal coliforms (MPN/ml) 9 C/4 6 <2 <2 C/2 6 2 <2 C 6 <2 <2 8 C/4 6 2 <2 C/2 6 <2 <2 C 6 <2 <2 *C=COD concentration of the effluent sample 98

Application of chlorine dioxide... COD Removal 6 22 42 46 49 51 Total COD removal in min. Total COD removal in 45 min. Total COD removal in 6 min. Figure 2: Total COD removal as a function of injected ClO 2 in different contact times (C= influent COD concentration) 6 COD Removal 28 31 37 35 49 45 47 Total COD removal in ph=7.75 Total COD removal in ph=5. Total COD removal in ph=9. Figure 3: Total COD removal as a function of injected ClO 2 in various ph s of treatment COD Removal 6 37 46 44 51 Total COD removal Dissolved COD removal Figure 4: Total and dissolved COD removal as a function of injected ClO 2 in one hour contact time (C = influent COD concentration) 99

F. Vaezi, et al. Discussion and Conclusion Most small scale ClO 2 generators in industrialized countries use sodium chlorite as the base chemical and sulfuric acid as the chlorite activator (White, 1992). This was the reason of choosing direct acid system for this study. However, some difficulties were experienced and according to the results, the concentrations of ClO 2 solutions prepared in the 4 tests were, 2, 27 and mgl -1, whereas it could be at least 2 mgl -1 (APHA, 1995). The conclusion is that even if there is only a slight deviation in operating conditions of synthesis, the quality of final solution would be affected. This matter should be considered in all treatment plants that would utilize this method for wastewater polishing. The yield could not be reported for ClO 2 generator, because the apparatus needed for determination of the probable chlorite and chlorate produced was not available. In the study of oxidation power of ClO 2 for effluent polishing, 3 contact times of, 45 and 6 minutes were chosen. Also, three concentrations of ClO 2 solutions were used which were as high as the total, half and one forth of the COD concentration of effluent sample under treatment. The best results were belong to the highest amounts of both contact time and ClO 2 concentration i.e., more than 6% removal in COD was achieved by 6 minutes contact to about mgl -1 ClO 2. However, for reducing the remained COD of secondary effluent to less than mgl -1, less ClO 2 concentrations and/or contact times were quite sufficient, for example, 15 mgl -1 ClO 2 in 1 hour contact time or mgl -1 in 45 minutes. But, reducing the contact time to less than 45 minutes is not recommended. According to Figure 4, it could be concluded that most of the considered reductions in COD are belong to dissolved fraction of this parameter. The changes of ph in common range of 5 to 9 have not appreciable effect on the efficiency of organics removal by ClO 2. It seems similar to the accepted fact of independence of disinfecting power of ClO 2 to ph changes. Disinfection power of ClO 2 is a well known phenomena and results of our study also indicate that complying with the standard of less than 2 total and fecal coliforms in ml of effluent would be easily achieved by ClO 2 treatment. Besides, organic and microbiological pollutants, TSS (often specified as turbidity) reduction is also recommended for all reuse applications of secondary effluents. ClO 2 treatment seems to be successful in complying with this standard too, for the reason that the reduction of about 6% of remained TSS is possible in 1 hour contact to ClO 2 in concentration equal to the amount of COD of treated effluent. Assessment of advanced treatment of secondary effluent by ClO 2 shows the considerable effect of this gas in reducing the remained pollutants of these effluents. Moreover ClO 2 has been shown to be effective disinfectant for bacterial indicators at Sahebgharanieh Treatment Plant. Safe production of ClO 2 is possible by direct acid system and required amounts for effluent polishing would be reduced by modifying the performance of treatment plants to have a typic effluent (/ or less for BOD and TSS) at all times and even further by upgrading them to produce effluents with new standard of / for example by employing a filtration step prior to ClO 2 injection. ClO 2 treatment seems to be an acceptable treatment technology to ensure good effluent quality for reuse applications such as agricultural and landscape irrigation and even for all the other urban nonpotable applications, when it is employed for filtered effluents. One final but important point for ClO 2 treatment concerns the required time. Because the data on ClO 2 in the references are limited, it is recommended to perform site specific testing to establish appropriate dosage ranges. However, the contact time for ClO 2 oxidation should be longer than minutes.

Application of chlorine dioxide... 6 58 47 36 TSS Removal TSS Removal References Figure 5: TSS removal as a function of injected ClO 2 in contact time of 1 hour (C = influent COD concentration) Aiet, E. and M. Hernandez, Determination of ClO 2, chlorine, chlorite and chlorate in water. AWWA, 64-69, 1984 APHA, AWWA and WEF, Standard methods for the examination of water and wastewater. 19 th. Ed., Washington DC., 1995 Eckenfelder, W. W., A. R. Bowers and J. A. Roth, Chemical Oxidation, Technomic, 2: 1-3, 1994. Jackman, A. P. and R. L. Powell, Hazardous waste treatment. np: 195-8, 1991 Metcalf and Eddy, Wastewater engineering, treatment and reuse. 4 th. Ed., McGraw Hill, 1258-1261, 3 Otterholm, H. and G. Jadesjo, Chlorine dioxides water treatment promise water. 21-22, Reynolds, T. D. and P. A. Richards, Unit operations and processes in environmental engineering. 2 nd. Ed., PWS Pub., 751-752, 1996 White, G. C., Handbook of chlorination and alternative disinfectants. 3 rd. Ed., Van Nostrand Reinhold, 89-, 1992 WPCF, Wastewater disinfection. MOP-FD-, 65-69, 1986 1

F. Vaezi, et al. 98