SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF GALVANIZED STEEL BARBED WIRE FOR FENCING ACCORDING ACCORDING TO IS 278:2009 (Fourth Revision)

Similar documents
1.1 All testing apparatus shall be periodically checked and calibrated. Records of such checks/calibration shall be maintained.

2.2 Copies of any records and other connected papers that may be required by the Bureau shall be made available at any time on request.

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF STEEL WIRE ROPES FOR GENERAL ENGINEERING PURPOSES ACCORDING TO IS 2266:2002 (Fourth Revision)

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF MALLIABLE CAST IRON PIPE FITTINGS ACCORDING TO IS: 1879:2010 (Third Revision)

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SELF BALLASTED LAMPS FOR GENERAL LIGHTING SERVICES ACCORDING TO IS 15111(Part 1 & 2):2002

2. TEST RECORDS - All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau.

STI /15392 /1 April, 2009

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

SCHEME OF TESTING AND INSPECTION CERTIFICATION OF PHOSPHORIC ACID, FOOD GRADE ACCORDING TO IS 10508:1983

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SWITCHES FOR DOMESTIC & SIMILAR PURPOSE ACCORDING TO IS 3854:1997

2. TEST RECORDS - All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau.

1.1 All testing apparatus shall be periodically checked and calibrated and records of such checks/calibration shall be maintained.

BUREAU OF INDIAN STANDARDS (CMD II)

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SWITCH-SOCKET-OUTLETS (NON-INTERLOCK TYPE) ACCORDING TO IS 15787:2008

DOC:STI/9573/2 January 2003

2. TEST RECORDS - All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau.

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF TAPER ROLLER BEARINGS ACCORDING TO IS 12102:1987

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III

DOC:STI/3087/4 September 2006

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF ALLUMINIUM ALLOY TUBES FOR IRRIGATION PURPOSES; WELDED TUBES ACCORDING TO IS: 7092 (PART I)-1992

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF GRAIN ORIENTED ELECTRICAL STEEL SHEET AND STRIP ACCORDING TO IS 3024:2006 (Second Revision)

2.2 Copies of any records and other connected papers that may be required by the Bureau shall be made available at any time on request.

1.1 All testing apparatus shall be periodically checked and calibrated. Records of such checks/calibration shall be maintained.

2. Test Records - All records of tests and analysis shall be kept in suitable forms approved by the Bureau.

BUREAU OF INDIAN STANDARDS (Central Marks Department - III) Our Ref : CMD-III/16: Oct 2006

2.1 All records of tests and inspection shall be kept in suitable forms approved by the Bureau.

2. TEST RECORDS - All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau.

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

2.0 TEST RECORDS - All records of tests and inspection shall be kept in suitable forms approved by the Bureau.

DOC: STI/8783(Part 4/Sec1)/1 August 1998

BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT III

SCHEME OF TESTING AND INSPECTION FOR CERIFICATION OF SISAL ROPES PART 1 UNTARRED VARIEITES ACCORDING TO IS 1321(Part 1):2003 (Fourth Revision)

1.1 All testing apparatus shall be periodically checked and calibrated and records of such checks/calibration shall be maintained.

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SILVERED GLASS MIRRORS FOR GENERAL PURPOSES ACCORDING TO IS :

SCHEME OF TESTING AND INSPECTION FOR CERTIFICAATION OF VENEERED DECORATIVE PLYWOOD ACCORDING TO IS 1328:1996 (Third Revision)

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

Doc: STI/1223(Section-2)/5 Oct 2003

2. TEST RECORDS - All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau.

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF RESPIRATORY PROTECTIVE DEVICES FULL FACE MASKS ACCORDING TO IS 14166:1994

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF COPPER SULPHATE ACCORDING TO IS :

1.1 All the testing apparatus shall be periodically checked and calibrated and records of such checks/calibration maintained.

BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III

SPECIFICATION ACCORDING TO IS

CENTRAL MARKS DEPARTMENT III. Our Ref : CMD-III/16: Mar 2007

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SLUICE VALVE FOR WATER WORKS PURPOSES (50 TO 1200 MM SIZE) ACCORDING TO IS 14846:2000

CENTRAL MARKS DEPARTMENT-III. Our Ref.:CMD-III/16:

BUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16:

1.1 All the testing apparatus shall be checked periodically and records of such checks shall be maintained.

2.0 TEST RECORDS- All records of tests and inspection shall be kept in suitable forms approved by the Bureau of Indian Standards.

1.2 All the testing equipment shall be periodically checked and calibrated and records of such checks/ calibration maintained.

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF FLAVOURED MILK ACCORDING TO IS 4709: 1968

(अन भ ग अध क र ) (स ए ड -3)

BUREAU OF INDIAN STANDARDS CMD-II

BUREAU OF INDIAN STANDARDS (CENTRAL MARKS DEPARTMENT-III)

CENTRAL MARKS DEPARTMENT II. Ref: CMD-II/16:

CENTRAL MARKS DEPARTMENT-III

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF TITANIUM DIOXIDE, ANATASE, FOR PAINTS ACCORDING TO IS :

Doc: STI/1166/6 July 2008

1.1 All the testing apparatus shall be periodically checked and calibrated and records of such checks/calibration maintained.

BUREAU OF INDIAN STANDARDS (Central Marks Department III) Our ref: CMD-III/16: November 2007

BUREAU OF INDIAN STANDARDS (Central Marks Department-III) Our Ref : CMD-III/16: October 2008

CMD-II(Legal) CMD-II/16:

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PLASTIC FEEDING BOTTLES ACCORDING TO IS : 1999 (Incorporating Amendment No.

2. Test Record - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

1.1 All the testing apparatus shall be periodically checked and calibrated and records of such checks/calibration maintained.

CENTRAL MARKS DEPARTMENT-II. Our Ref: CMD-II/16: Subject: Information of revised version of Alumino-Ferric as per IS 299.

CENTRAL MARKS DEPARTMENT-II

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF BORAX ACCORDING TO IS 1109:1980

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SHAVING CREAMS ACCORDING TO IS ( Incorporating Amendment No.

2. Test Records - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

2. TEST RECORDS - All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau.

CENTRAL MARKS DEPARTMENT-2. Ref: CMD-2/16:

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF HAND OPERATED STIRRUP-TYPE SPRAYER ACCORDING TO IS 1971:1996 (Fifth Revision)

GUIDELINES FOR IMPLEMENTATION OF IS 13334(PART 1):2014

क न द र य म ह व भ ग भ स द भ- स ए ड -III/16: IS

1.1 All testing apparatus shall be periodically checked and calibrated and records of such checks/calibration shall be maintained.

CENTRAL MARKS DEPARTMENT-3. Our Ref: CMD-3/16: Subject: STI as per IS 13714: 1993 DUNNAGE PALLETS-WAREHOUSING

CENTRAL MARKS DEPARTMENT-II

BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III

2. 0 Test Records - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

CENTRAL MARKS DEPARTMENT (FCT) Ref: CMD-II/16:

(ड चद र ) ञ न क ई (स ए ड -3)

ALUMINIUM CONDUCTORS FOR OVERHEAD TRANSMISSION PURPOSES

CENTRAL MARKS DEPARTMENT (FCT) Ref: CMD-II/16:2933 (Part 1)

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF TOOTH PASTE ACCORDING TO IS 6356: 2001 (Third Revision)

2. 0 Test Records - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF ORDINARY PORTLAND CEMENT, 33 GRADE ACCORDING TO

CENTRAL MARKS DEPARTMENT-2

2. TEST RECORDS: All records of tests and analysis shall be kept in suitable forms approved by the Bureau.

2. Test Record - All records of analysis and tests shall be kept in suitable forms approved by the Bureau of Indian Standards.

स ल न प ए, (द सर स श धन) (स श धन 1 स 6 श "मल)

CENTRAL MARKS DEPARTMENT II. Subject: Implementation of revised Indian Standard Specification for Nitric Acid

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF 53 GRADE ORDINARY PORTLAND CEMENT ACCORDING TO IS:

(अAण प छक यल ) व D. ब (क.म.0व. 2) CENTRAL MARKS DEPARTMENT-2. Our Ref: CMD-2/16:

MARKS DEPARTMENT-III. ROs/BOs may also propose the implementation date in view of revision of Indian

Subject: Implementation of IS 9798:2013 Low Pressure Regulators for use with Liquefied Petroleum Gas (LPG) Specification (Second Revision).

क द य म हर व भ ग-2 CENTRAL MARKS DEPARTMENT -2

BUREAU OF INDIAN STANDARDS (CENTRAL MARKS DEPARTMENT-III) Our Ref: CMD-III/16:1239(Pt 1) 11 Oct 2004

Transcription:

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF GALVANIZED STEEL BARBED WIRE FOR FENCING ACCORDING ACCORDING TO (Fourth Revision) DOC: STI/278/, 1 LABORATORY - A laboratory shall be maintained which shall be suitably equipped and staffed, where tests shall be carried out in accordance with the methods given in the specification. 2 TEST RECORDS All records of tests, inspection and calibration shall be kept in suitable forms approved by the Bureau. 2.1 All testing apparatus/measuring instruments shall be periodically checked and calibrated and records of such checks/calibration shall be maintained. 2.2 Copies of any records and other connected papers that may be required by the Bureau shall be made available at any time on request. 3 It is recommended that, as far as possible. Statistical Quality Control (SQC) methods may be used for controlling the quality during production as envisaged in this scheme (See IS 397 (Part 1) to IS 397 (Part IV). 3.1 In addition, effort should be made to gradually introduce a-quality management System as per IS/ISO 9001. 4 STANDARD MARK - The Standard Mark as given in Column (1) of the first schedule of the licence shall be printed/stamped/stenciled on each reel of galvanized steel barbed, provided always that the barbed in each reel to which this mark is thus applied conforms to every requirement of the specification. 4.1 MARKING - In addition, the following information shall be given on the label applied to each reel: a) Name of the manufacturer or his recognized trade mark, b) Type and designation of the barbed ; c) Diameter of the line and point s; d) Barb-spacing; e) Length and/or mass of reel; and f) Identification in code or otherwise to enable the date and lot of manufacture to be traced back to factory records. g) Licence Number (i.e. CM/L.) 4.2 PACKING - Unless otherwise agreed to between the supplier and the purchaser, the barbed shall be supplied in metal or wooden reels. of barbed shall be wound and fastened completely.. LEVELS OF CONTROL: The tests as indicated in Table 1 and at the levels of control specified therein shall be carried out on the whole production of the factory which is covered by this scheme and appropriate records and charts maintained in accordance with paragraph 2above. All the production which conforms to the Indian Standard and covered by this licence shall be marked with certification mark of the Bureau.

DOC: STI/278/,.1 On the basis of tests, the decision regarding the conformity or otherwise of the product to the various requirements of the specification shall be made as follows..1.1 MANUFACTURE, SIZES AND FREEDOM FROM DEFECTS: A sample from each reel shall be checked for the manufacture, sizes and freedom from defects as per clauses, 7 and 8 of the Indian Standard and the reels found defective shall be rectified..2 In respect of all other clauses of the specification, the factory shall maintain appropriate controls and checks to ensure that their product conforms to the various requirements of the specification. 7 REJECTION: A separate record shall be maintained giving information relating to the rejection of barbed not conforming to the specification and the method of its disposal. Such material shall not be stored together with that conforming to the specification. 8 SAMPLE The licensee shall supply, free of charge the sample required in accordance with the Bureau of Indian standard (certification) Regulations, 1988 as subsequently amended, from the factory or godowns. The Bureau shall pay for the samples taken by it from open market. 9 REPLACEMENT Whenever a compliant is received soon after the goods with standard mark have been purchased and used, and if there is adequate evidence that goods have not been misused defective goods are replaced free of cost by the licensee in case the compliant is proved to be genuine and the warranty period (where applicable) has not expired. The final authority to judge the conformity of the product to the Indian Standard shall be with the Bureau. The firm shall have own complaint investigation system as per IS/ISO 10002. 9.1 In the event of any damage caused by the goods bearing the standard mark or claim being filed by consumers against BIS Standard Mark, and not conforming to the relevant Indian Standard entire liability arising out of such non conforming product shall be of the licensee and BIS shall not in any way be responsible in such cases. 10 STOP MARKING The marking of the product shall be stopped under intimation to the Bureau if at any time there is any difficulty in maintaining the conformity of the product to the specification or the testing equipment goes out of order. The marking may be resumed as soon as the defects are removed under intimation to the Bureau. 10.1 The marking of the product shall be stopped immediately if directed to do so by Bureau for any reason. The marking may then be resumed only after permission by the Bureau. The information regarding resumption of the marking shall also be sent to the Bureau. 11 PRODUCTION DATA The licensee shall send to BIS as per the enclosed proforma -1 to be authenticated by a Chartered Accountant a statement of quantity produced, marked and exported by him and trade value thereof at the end of each operative year of the licence. Table1

DOC: STI/278/, GALVANIZED STEEL BARBED WIRE FOR FENCING ACCORDING TABLEL 1 LEVELS OF CONTROL (Para of the Scheme of Testing and Inspection) Sr. No. Requirement 6 Material Sizes Diameter of line Diameter of point Distance between two barbs No. of lays between two Consecutive barbs TEST DETAILS Clause Test Method Reference IS 280 LEVELS OF CONTROL No. of Lot Size Frequency REMARKS Samples In case consignment is supported by a test certificate Each consignment ensuring conformity to IS 280, no further testing is required. 7 9 Manufacture Mass of completed barbed Freedom from defects 7.1 & 7.2 9 12 Tests 12.1 Tensile test of line 12.1 Three Each consignment or part thereof. 12.1 Tensile test of completed barbed 12.1 12.2 Zinc coating Line Point 12.2.1 12.2.2 8 Chromating 8 12.3 Ductility test 12.3 Every 0 th reel of barbed of one type or part thereof manufactured in a day. Every 2 th reel of barbed & one type or part thereof manufactured in a shift with a minimum of two per shift. If the sample fails, sample from two reels manufactured before and two reels after the non-conforming reel shall be tested. the reels shall be marked if these four samples are found to be satisfactory. Protective chromatic conversion coating may be given on the barbed as per agreement with the purchaser. Table II

DOC: STI/278/, TABLE II LEVELS OF CONTROL Test Results for Galvanized Steel Barbed Wire for Fencing SNo Date of stranding Batch No. Inspection for workmanship and freedom from defects Total Number Number reels accepted rejected inspected Diameter of line Dimensions Test Details Tensile test of line Steel Diameter of point Distance between two barbs Tensile strength Ductility test Coating test Weight Consignm ent Number Voucher number Supplier Test certificate details Batch accepted or rejected Remarks (Mention if retests were conducte d and if so, results)

DOC: STI/278/, PERFORMA - 1 PROFORMA FOR OBTAINING PRODUCTION DETAILS Period covered Name of Licensee CM/L No. Name of Articles (s) Grade/Type/Size/Variety/Class/Rating IS No. 1.1 Brand/Trade/Name(s) of BIS Certification Marked Products 2.0 Total production of the articles(s) Licensed for certification marking 2.1 Total production of the article(s) Conforming to Indian Standard 3.0 Production covered with BIS Certification Mark and its Value a) Quantity b) Value (Rs.) 3.1 Brand Name used on production covered under BIS Certification Mark 3.2 Calculation of marking fee on unit-rate basis; Marking Fee per unit a) Unit b) Quantity covered with BIS Certification Mark c) Marking fee rounded off in whole rupees as obtained by applying unit rates given in (a) on quantity given in (b) Note: Incase a clause is not applicable, suitable remarks may be given against it. 4.0 Quantity not covered with BIS Certification Mark. If any, and the reasons for such non-coverage 4.1 Brand Name under with non certified goods were sold.0 Quantity Exported with BIS Standard Mark and its value.1 Brand Name under which BIS Certified goods are exported 6.0 Authentication by Chartered Accountant