DETAILS GUIDE STRATASHIELD STANDARD FLOORING TABLE OF CONTENTS

Similar documents
SCS-01 Termination Detail for Lining at Nose Angle Iron. SCS-02 Termination Detail for Lining at Circular and Trench Flooring Drain

ELS-1 Leading Edge Termination. ELS-2 Termination Detail For Embedded Metals. ELS-3 Sleeved or Non-Sleeved Pipe Penetration

PLS-01 Leading Edge Termination. PLS-02 Termination Detail For Embedded Metals. PLS-03 Sleeved or Non-Sleeved Pipe Penetration

Semstone Construction Details

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS

SECTION TILING

GCP APPLIED TECHNOLOGIES PERM-A-BARRIER VPL 50

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

May 8, 2017 ADDENDUM #1. IFB Resin Floor System For Highway Department Central District Building

FLUID APPLIED WATERPROOFING

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 07 THERMAL AND MOISTURE PROTECTION SECTION JOINT SEALANT AND EXPANSION CONTROL

***************************************************************************************************************

EPOXY TERRAZZO 1 REV. 8/02

SECTION CERAMIC and QUARRY TILE

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

APPLICATION INSTRUCTIONS ECO-FAST 100% SOLIDS DECK COATING SYSTEMS

TILING Lutheran Church of the Holy Spirit

SECTION JOINTING OF EXTERIOR VERTICAL SURFACES CONSTRUCTION STANDARDS

CONSTRUCTION WATERPROOFING HANDBOOK QUESTIONS

SECTION RESILIENT FLOORING

Engine Bay Floors Floor Resurfacing 4000

2. Subfloor Preparation - Removal of Existing Floor Coverings

SECTION SUBSURFACE PREPARATION FOR FLOOR FINISHES

Gensler 2014/06/16 Hertz Global Headquarters ISSUE FOR BUILDING PERMIT Estero, Florida SECTION

SECONDARY CONTAINMENT COATING SPECIFICATION

B. Store products in dry spaces protected from the weather, with ambient temperatures maintained between 50 and 90 deg F (10 and 32 deg C).

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Student Services & Classroom Addition

Product Systems EXTERNAL WATERPROOFING OF BELOW GROUND CONCRETE WALL & SLAB. AQUAFIN-IC CRYSTALLINE WATERPROOFING Schematic sketches

SECTION EPOXY FLOORING SYSTEMS

Desco Granite Flooring Specifications

SECTION TILING PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes: 1. Ceramic tile. 2. Waterproof membrane. 3. Metal edge strips.

STRATASHIELD PROTECTIVE FLOOR & WALL COATINGS BRINGING PERFORMANCE TO THE SURFACE

Construction Standards PAGE

Application Guide for. MasterSeal Roof 3500 (MasterSeal M 820 Membrane)

Atlas Chempruf TM. Coating and Lining Systems

B-1 DIRECT WATERPROOFING APPLICATION TO LAGGING FOLD OVER ARMORCLAY 1000 FOR GRADE LINE TERMINATION VERTICAL GEO-MAT C DRAIN 110 OR 150 FASTENERS

1 PVC or ABS drain with strainer

TECHNICAL BULLETIN TB006

Installation Guide LVP Glue Down

SOUND REDUCER INSTALLATION MANUAL. Manufactured in the U.S.A. by: Ecore. Revised 08/28/2017 Supersedes all previous versions Check website for updates

SECTION EPOXY RESIN FLOORING WITH INTEGRAL COVE BASE

Ultra Wall System. CAD Detail Sets

SECTION EPOXY RESIN FLOORING WITH INTEGRAL COVE BASE

Pacific Polymers Elasto-Deck 5000MR Guide Specification

SECTION EPOXY RESIN FLOORING WITH INTEGRAL COVE BASE

SECTION SELF-ADHERING SHEET WATERPROOFING (PRM / PROTECTED WALL SYSTEM)

1.6 QUALITY ASSURANCE A. Source Limitations for Tile: Obtain tile of each type and color or finish from one source or producer.

LVP GLUE DOWN INSTALLATION GUIDE PAGE 1 of 6

Installation Instructions

3. Aesthetic Groove. 5. Window Head (Flush) 6. Window Head (Recessed) 7. Window Jamb Detail (Flush) 8. Window Jamb Detail (Recessed)

ARCHITECTURAL GUIDE SPECIFICATIONS

A. The work of this section includes, but is not limited to, the following:

SECTION RESILIENT SHEET FLOORING

HI-TEK POLYMERS T-Poxy Terrazzo Arch Data

Installation Guide Sto RapidGuard

SECTION CERAMIC TILING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

AQUAFIN-2K/M FLEXIBLE CEMENTITIOUS WATERPROOFING

Shock-Crete. The Ultimate Thermal Shock Resistant Flooring System

HYDRO BAN. Installation instructions for Australia TDS-1003 SUITABLE SUBSTRATES SUBSTRATE CONDITIONS

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Balconies Information. How to waterproof and reduce efflorescence

A. This Section includes traffic coatings for the following applications:

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

CORROSION ENGINEERING SPECIFICATION FOR INSTALLATION

1.2 Reference Standard: NOFMA - National Oak Flooring Manufacturers Association Grading Standards.

METHOD STATEMENT 003 SCYRON-CEMENT SHEETING BALCONY WATERPROOFING FOR DIRECT FIXED TILES

SikaProof Bentonite Plastic DPM overlap - Compacted Backfill Scale 1:5. Detail no: SB01 - Nov 2013

SECTION PAVER TILE

STANDARD INSTALLATION GUIDELINES

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

PROFILES AND TRANSITIONS

SECTION SELF-ADHERING SHEET WATERPROOFING (650 MEMBRANE SYSTEM)

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

RESINOUS FLOORING

DIVISION 9 - FINISHES

ARDEX UI 720 FLEXBONE

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DISTRIBUTION EQUIPMENT

Installation Instructions

Senturion TM I Wall System

***********************************************************************************

Delivery, Storage, and Handling

SECTION CONCRETE TOPPING

ECOsilence. TECHNICAL MANUAL Installation Warranty. Manufactured in the U.S.A. by:

Bush Elem. Addition & Alterations QUARRY TILE SECTION QUARRY TILE PART 1 - GENERAL

SECTION INTERIOR CONCRETE SLAB REPAIRS AND FLOOR JOINT FILLER REPLACEMENT

SECTION FLUID-APPLIED WATERPROOFING

SECTION RESILIENT BASE AND ACCESSORIES

Joint Sealants.

WATERPROOFING OF WET ROOms

Channel Drain Shower Base. Aqua Line pro. Installation Instructions

Broadcast Parking Garage System

MAJESTIC FLOOR MEMBRANE PRODUCT GUIDE

LATICRETE HYDROBAN Waterproof Membrane

Guide Specification Auto-Gard Section Vehicular Traffic Coatings

SECTION RESINOUS FLOORING

Section 710. WATERPROOFING AND PROTECTIVE COVERS

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Transcription:

TABLE OF CONTENTS DETAILS GUIDE STRATASHIELD STANDARD FLOORING TNEMEC COMPANY INCORPORATED 6800 Corporate Drive, Kansas City, MO 64120 1-800-TNEMEC1 www.tnemec.com Published techincal data, instructions, and pricing are subject to change without notice. Contact your Tnemec technical representative for current technical data, instructions, and pricing. Warranty information: The service life of Tnemec s coatings will vary. For warranty, limitation of seller s liability, and product information, please refer to Tnemec s Product Data Sheets at www.tnemec.com or contact your Tnemec Technical Representative. 6/2014 SFS-01 Leading Edge Termination Detail for Self-Leveling and Laminate Flooring Systems SFS-02 Leading Edge Termination Detail for Mortar Flooring Systems SFS-03 Termination Detail for Mortar at Nose Angle Iron at Loading Dock or Building Joint SFS-04 Termination Detail at Nose Angle Iron at Stair Tread or Building Joint SFS-05 Control Joint Treatment Detail with No Potential Movement SFS-06 Control Joint Treatment Detail with Potential Movement SFS-07 Expansion/Isolation Joint Treatment Detail SFS-08 Treatment for Non-Moving Crack Treatment Detail SFS-09 Treatment for Moving Crack Treatment Detail SFS-10 Treatment for Bridging Multiple Non-Moving Hairline Cracks SFS-11 Cant Cove Detail SFS-12 Spoon Cove Detail SFS-13 Rolled Radius Cove SFS-14 Rolled Radius Cove Detail Eliminating Top Edge SFS-15 Cove Detail for Flush Transition FRP SFS-16 Cove Detail for Flush Transition Tile SFS-17 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems without cove SFS-18 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems with cove SFS-19 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems with cove SFS-20 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems with cove SFS-21 Floor Drain Detail without Sealant SFS-22 Floor Drain Detail with Sealant SFS-23 Sleeved or Non-Sleeved Pipe Penetration in Floor Detail

TABLE OF CONTENTS Rolled Radius Cove Detail...SFS-13 Rolled Radius Cove Detail Eliminating Top Edge...SFS-14 Cove Detail for Flush Transition FRP...SFS-15 Cove Detail for Flush Transition Tile...SFS-16 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems without cove...sfs-17 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems with cove...sfs-18 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems with cove...sfs-19 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems with cove...sfs-20 Floor Drain Detail without Sealant...SFS-21 Floor Drain Detail with Sealant...SFS-22 Sleeved or Non-Sleeved Pipe Penetration in Floor Detail...SFS-23

STRATASHIELD FLOORING 1/4" WIDE (6.35mm) 1/4" DEEP (6.35mm) SAWCUT TERMINATION 1/4 (6.35mm) DEEP LEADING EDGE TERMINATION DETAIL FOR SELF-LEVELING AND LAMINATE FLOORING S NO. SFS-01

CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MINIMUM 3" (76.2mm) STRATASHIELD FLOORING 1/2" (12.7mm) DEEP SAWCUT SAWCUT TERMINATION 1/2 (12.7mm) DEEP LEADING EDGE TERMINATION DETAIL FOR MORTAR FLOORING S NO. SFS-02

CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MINIMUM 3" (76.2mm) STRATASHIELD FLOORING EMBEDDEDNOSING ANGLE IRON 1/2" (12.7mm) SAWCUT TERMINATION DETAIL FOR MORTAR AT NOSE ANGLE IRON AT LOADING DOCK OR BUILDING JOINT NO. SFS-03

TREAD NOSING STRATASHIELD FLOORING THICKNESS AS SPECIFIED TERMINATION DETAIL AT NOSE ANGLE IRON AT STAIR TREAD OR BUILDING JOINT NO. SFS-4

STRATASHIELD FLOORING FILLER MATERIAL NOTE: USE SERIES 215 OR STRATASHIELD 100% SOLIDS EPOXY MIXED WITH FUMED SILICA, SILICA FLOUR OR FINE AGGREGATE FOR FILLER MATERIAL CONTROL JOINT WITH NO POTENTIAL MOVEMENT NO. SFS-5

STRATASHIELD FLOORING FLEXIBLE JOINT SEALANT 1/2" (12.7mm) DEEP SAWCUT NOTE: FLEXIBLE JOINT SEALANT WIDTH TO DEPTH RATIO SHOWN IS APPROXIMATELY 2:1. DETAIL CAN BE BUILT BY INSTALLING FLOOR OVER JOINT, RESAWCUTTING, AND INSTALLING SEALANT. CONTROL JOINT WITH POTENTIAL MOVEMENT NO. SFS-06

BACKER ROD AND FLEXIBLE JOINT SEALANT STRATASHIELD FLOORING 1/2" (12.7mm) 1/4" (6.35mm) EXISTING EXPANSION/ ISOLATION JOINT MATERIAL NOTE: FLEXIBLE JOINT SEALANT WIDTH TO DEPTH RATIO SHOWN IS APPROXIMATELY 2:1. DETAIL CAN BE BUILT BY INSTALLING FLOOR OVER JOINT, RESAWCUTTING, AND INSTALLING BACKER ROD AND SEALANT. EXPANSION/ISOLATION JOINT TREATMENT DETAIL NO. SFS-07

PATCH WITH FILLER MATERIAL PRIOR TO INSTALLING STRATASHIELD FLOORING STRATASHIELD FLOORING NOTE: USE SERIES 215 OR STRATASHIELD 100% SOLIDS EPOXY MIXED WITH FUMED SILICA OR SILICA FLOUR FOR FILLER MATERIAL. ROUTE OUT CRACK PRIOR TO PATCHING IF CRACK IS LARGER THAN 1/16 (1.58mm). TREATMENT FOR NON-MOVING CRACKS NO. SFS-08

FLEXIBLE JOINT SEALANT ROUTE OUT EXISTING CRACK AND PATCH WITH FILLER MATERIAL PRIOR TO INSTALLING STRATASHIELD FLOORING STRATASHIELD FLOORING NOTE: USE SERIES 215 OR STRATASHIELD 100% SOLIDS EPOXY MIX WITH FUMED SILICA, SILICA FLOUR OR FINE AGGREGATE FOR FILLER MATERIAL FLEXIBLE JOINT SEALANT WIDTH TO DEPTH RATIO SHOWN IS APPROXIMATELY 2:1. DETAIL CAN BE BUILT BY INSTALLING FLOOR OVER CRACK, RESAWCUTTING, AND INSTALLING SEALANT. TREATMENT FOR MOVING CRACKS NO. SFS-09

STRATASHIELD FLOORING SERIES 206 FLEXIBLE UNDERLAYMENT 30-40 MILS HAIRLINE CRACKS NOTE: USE FLEXIBLE UNDERLAYMENT TO BRIDGE HAIRLINE CRACKS IN FLOORS WHERE NO EVIDENCE OF SETTLEMENT OR MOVEMENT AND WHERE FLOOR IS NOT EXPOSED TO DRASTIC THERMAL CHANGE. TREATMENT FOR BRIDGING MULTIPLE NON-MOVING HAIRLINE CRACKS NO. SFS-10

CONCRETE, CMU, WALL BOARD, ETC. 45 DEGREE CANT COVE 1" - 2" HEIGHT (25.4mm - 50.8mm) STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. CANT COVE DETAIL NO. SFS-11

CONCRETE, CMU, WALL BOARD, ETC. SPOON COVE COVE HEIGHT 3/4-1 (19mm-25mm) STRATASHIELD FLOORING EXISTING CONCRETE SUBSTRATE NOTE: USE DRY TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. SPOON COVE DETAIL NO. SFS-12

CONCRETE, CMU, WALL BOARD, ETC. METAL OR PLASTIC COVE STRIP (OPTIONAL) ROLLED RADIUS COVE COVE HEIGHT 4-6 (100mm-150mm) STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. ROLLED RADIUS COVE DETAIL NO. SFS-13

CONCRETE, CMU, WALL BOARD, ETC. SERIES 215 SURFACING EPOXY METAL OR PLASTIC COVE STRIP COVE HEIGHT 4-6 (100mm-150mm) ROLLED RADIUS COVE STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. ROLLED RADIUS COVE DETAIL ELIMINATING TOP EDGE NO. SFS-14

CONCRETE, CMU, WALL BOARD, ETC. FRP PANEL FRP TRIM STRIP COVE HEIGHT 4-6 (100mm-150mm) ROLLED RADIUS COVE STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE AND BASE. COVE DETAIL FOR FLUSH TRANSITION FRP NO. SFS-15

CONCRETE, CMU, WALL BOARD, ETC. TILE COVE HEIGHT 4-6 (100mm-150mm) ROLLED RADIUS COVE STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE AND BASE. COVE DETAIL FOR FLUSH TRANSITION TILE NO. SFS-16

CONCRETE, CMU, WALL BOARD, ETC. BACKER ROD AND FLEXIBLE JOINT SEALANT STRATASHIELD FLOORING EXISTING EXPANSION / ISOLATION EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITHOUT COVE NO. SFS-17

METAL OR PLASTIC COVE STRIP (OPTIONAL) CONCRETE, CMU, WALL BOARD, ETC. *BOND BREAKER SAW CUT AND FILL WITH FLEXIBLE SEALANT STRATASHIELD FLOOR TOPPING EXISTING EXPANSION / ISOLATION POLYETHYLENE BACKER ROD NOTE: *BOND BREAKER - EXCEED RECOAT WINDOW ON PRIMER 201, 222, 237, ETC. OR USE DUCT TAPE EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITH COVE NO. SFS-18

CONCRETE, CMU, WALL BOARD, ETC. METAL OR PLASTIC COVE STRIP (OPTIONAL) STRATASHIELD FLOOR TOPPING SAW CUT AND FILL WITH FLEXIBLE SEALANT EXISTING CONCRETE SUBSTRATE EXISTING EXPANSION / ISOLATION KEY IN WITH STRATASHIELD TOPPING 1/4 (6.35mm) TO 1/2 (12.7mm) DEEP POLYETHYLENE BACKER ROD (OPTIONAL) EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITH COVE NO. SFS-19

CONCRETE, CMU, WALL BOARD, ETC. METAL OR PLASTIC COVE STRIP (OPTIONAL) METAL OR PLASTIC TERMINATION STRIP STRATASHIELD FLOOR TOPPING EXISTING CONCRETE SUBSTRATE EXISTING EXPANSION / ISOLATION KEY IN WITH STRATASHIELD FLOOR TOPPING 1/4 (6.35mm) TO 1/2 (12.7mm) DEEP POLYETHYLENE BACKER ROD (OPTIONAL) EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITH COVE NO. SFS-20

CAST-IN-PLACE CIRCULAR FLOOR DRAIN CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MIN. 3" (76.2mm) STRATASHIELD FLOORING FLOOR DRAIN DETAIL WITHOUT SEALANT NO. SFS-21

CAST-IN-PLACE CIRCULAR FLOOR DRAIN CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MIN. 3" (76.2mm) STRATASHIELD FLOORING FLEXIBLE JOINT SEALANT FLOOR DRAIN DETAIL WITH SEALANT NO. SFS-22

EXISTING PIPE OR SLEEVE 1-2 (25.4mm - 50.5mm) HEIGHT FLEXIBLE JOINT FILLER STRATASHIELD FLOORING BACKER ROD SLEEVED OR NON-SLEEVED PIPE PENETRATION IN FLOOR DETAIL NO. SFS-23