TABLE OF CONTENTS DETAILS GUIDE STRATASHIELD STANDARD FLOORING TNEMEC COMPANY INCORPORATED 6800 Corporate Drive, Kansas City, MO 64120 1-800-TNEMEC1 www.tnemec.com Published techincal data, instructions, and pricing are subject to change without notice. Contact your Tnemec technical representative for current technical data, instructions, and pricing. Warranty information: The service life of Tnemec s coatings will vary. For warranty, limitation of seller s liability, and product information, please refer to Tnemec s Product Data Sheets at www.tnemec.com or contact your Tnemec Technical Representative. 6/2014 SFS-01 Leading Edge Termination Detail for Self-Leveling and Laminate Flooring Systems SFS-02 Leading Edge Termination Detail for Mortar Flooring Systems SFS-03 Termination Detail for Mortar at Nose Angle Iron at Loading Dock or Building Joint SFS-04 Termination Detail at Nose Angle Iron at Stair Tread or Building Joint SFS-05 Control Joint Treatment Detail with No Potential Movement SFS-06 Control Joint Treatment Detail with Potential Movement SFS-07 Expansion/Isolation Joint Treatment Detail SFS-08 Treatment for Non-Moving Crack Treatment Detail SFS-09 Treatment for Moving Crack Treatment Detail SFS-10 Treatment for Bridging Multiple Non-Moving Hairline Cracks SFS-11 Cant Cove Detail SFS-12 Spoon Cove Detail SFS-13 Rolled Radius Cove SFS-14 Rolled Radius Cove Detail Eliminating Top Edge SFS-15 Cove Detail for Flush Transition FRP SFS-16 Cove Detail for Flush Transition Tile SFS-17 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems without cove SFS-18 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems with cove SFS-19 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems with cove SFS-20 Expansion/Isolation Joint Treatment Detail at Wall/ Floor Interface for Laminate and Mortar Systems with cove SFS-21 Floor Drain Detail without Sealant SFS-22 Floor Drain Detail with Sealant SFS-23 Sleeved or Non-Sleeved Pipe Penetration in Floor Detail
TABLE OF CONTENTS Rolled Radius Cove Detail...SFS-13 Rolled Radius Cove Detail Eliminating Top Edge...SFS-14 Cove Detail for Flush Transition FRP...SFS-15 Cove Detail for Flush Transition Tile...SFS-16 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems without cove...sfs-17 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems with cove...sfs-18 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems with cove...sfs-19 Expansion/Isolation Joint Treatment Detail at Wall/Floor Interface for Laminate and Mortar Systems with cove...sfs-20 Floor Drain Detail without Sealant...SFS-21 Floor Drain Detail with Sealant...SFS-22 Sleeved or Non-Sleeved Pipe Penetration in Floor Detail...SFS-23
STRATASHIELD FLOORING 1/4" WIDE (6.35mm) 1/4" DEEP (6.35mm) SAWCUT TERMINATION 1/4 (6.35mm) DEEP LEADING EDGE TERMINATION DETAIL FOR SELF-LEVELING AND LAMINATE FLOORING S NO. SFS-01
CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MINIMUM 3" (76.2mm) STRATASHIELD FLOORING 1/2" (12.7mm) DEEP SAWCUT SAWCUT TERMINATION 1/2 (12.7mm) DEEP LEADING EDGE TERMINATION DETAIL FOR MORTAR FLOORING S NO. SFS-02
CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MINIMUM 3" (76.2mm) STRATASHIELD FLOORING EMBEDDEDNOSING ANGLE IRON 1/2" (12.7mm) SAWCUT TERMINATION DETAIL FOR MORTAR AT NOSE ANGLE IRON AT LOADING DOCK OR BUILDING JOINT NO. SFS-03
TREAD NOSING STRATASHIELD FLOORING THICKNESS AS SPECIFIED TERMINATION DETAIL AT NOSE ANGLE IRON AT STAIR TREAD OR BUILDING JOINT NO. SFS-4
STRATASHIELD FLOORING FILLER MATERIAL NOTE: USE SERIES 215 OR STRATASHIELD 100% SOLIDS EPOXY MIXED WITH FUMED SILICA, SILICA FLOUR OR FINE AGGREGATE FOR FILLER MATERIAL CONTROL JOINT WITH NO POTENTIAL MOVEMENT NO. SFS-5
STRATASHIELD FLOORING FLEXIBLE JOINT SEALANT 1/2" (12.7mm) DEEP SAWCUT NOTE: FLEXIBLE JOINT SEALANT WIDTH TO DEPTH RATIO SHOWN IS APPROXIMATELY 2:1. DETAIL CAN BE BUILT BY INSTALLING FLOOR OVER JOINT, RESAWCUTTING, AND INSTALLING SEALANT. CONTROL JOINT WITH POTENTIAL MOVEMENT NO. SFS-06
BACKER ROD AND FLEXIBLE JOINT SEALANT STRATASHIELD FLOORING 1/2" (12.7mm) 1/4" (6.35mm) EXISTING EXPANSION/ ISOLATION JOINT MATERIAL NOTE: FLEXIBLE JOINT SEALANT WIDTH TO DEPTH RATIO SHOWN IS APPROXIMATELY 2:1. DETAIL CAN BE BUILT BY INSTALLING FLOOR OVER JOINT, RESAWCUTTING, AND INSTALLING BACKER ROD AND SEALANT. EXPANSION/ISOLATION JOINT TREATMENT DETAIL NO. SFS-07
PATCH WITH FILLER MATERIAL PRIOR TO INSTALLING STRATASHIELD FLOORING STRATASHIELD FLOORING NOTE: USE SERIES 215 OR STRATASHIELD 100% SOLIDS EPOXY MIXED WITH FUMED SILICA OR SILICA FLOUR FOR FILLER MATERIAL. ROUTE OUT CRACK PRIOR TO PATCHING IF CRACK IS LARGER THAN 1/16 (1.58mm). TREATMENT FOR NON-MOVING CRACKS NO. SFS-08
FLEXIBLE JOINT SEALANT ROUTE OUT EXISTING CRACK AND PATCH WITH FILLER MATERIAL PRIOR TO INSTALLING STRATASHIELD FLOORING STRATASHIELD FLOORING NOTE: USE SERIES 215 OR STRATASHIELD 100% SOLIDS EPOXY MIX WITH FUMED SILICA, SILICA FLOUR OR FINE AGGREGATE FOR FILLER MATERIAL FLEXIBLE JOINT SEALANT WIDTH TO DEPTH RATIO SHOWN IS APPROXIMATELY 2:1. DETAIL CAN BE BUILT BY INSTALLING FLOOR OVER CRACK, RESAWCUTTING, AND INSTALLING SEALANT. TREATMENT FOR MOVING CRACKS NO. SFS-09
STRATASHIELD FLOORING SERIES 206 FLEXIBLE UNDERLAYMENT 30-40 MILS HAIRLINE CRACKS NOTE: USE FLEXIBLE UNDERLAYMENT TO BRIDGE HAIRLINE CRACKS IN FLOORS WHERE NO EVIDENCE OF SETTLEMENT OR MOVEMENT AND WHERE FLOOR IS NOT EXPOSED TO DRASTIC THERMAL CHANGE. TREATMENT FOR BRIDGING MULTIPLE NON-MOVING HAIRLINE CRACKS NO. SFS-10
CONCRETE, CMU, WALL BOARD, ETC. 45 DEGREE CANT COVE 1" - 2" HEIGHT (25.4mm - 50.8mm) STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. CANT COVE DETAIL NO. SFS-11
CONCRETE, CMU, WALL BOARD, ETC. SPOON COVE COVE HEIGHT 3/4-1 (19mm-25mm) STRATASHIELD FLOORING EXISTING CONCRETE SUBSTRATE NOTE: USE DRY TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. SPOON COVE DETAIL NO. SFS-12
CONCRETE, CMU, WALL BOARD, ETC. METAL OR PLASTIC COVE STRIP (OPTIONAL) ROLLED RADIUS COVE COVE HEIGHT 4-6 (100mm-150mm) STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. ROLLED RADIUS COVE DETAIL NO. SFS-13
CONCRETE, CMU, WALL BOARD, ETC. SERIES 215 SURFACING EPOXY METAL OR PLASTIC COVE STRIP COVE HEIGHT 4-6 (100mm-150mm) ROLLED RADIUS COVE STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE. ROLLED RADIUS COVE DETAIL ELIMINATING TOP EDGE NO. SFS-14
CONCRETE, CMU, WALL BOARD, ETC. FRP PANEL FRP TRIM STRIP COVE HEIGHT 4-6 (100mm-150mm) ROLLED RADIUS COVE STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE AND BASE. COVE DETAIL FOR FLUSH TRANSITION FRP NO. SFS-15
CONCRETE, CMU, WALL BOARD, ETC. TILE COVE HEIGHT 4-6 (100mm-150mm) ROLLED RADIUS COVE STRATASHIELD FLOORING NOTE: USE DRY MIXED TROWELABLE MORTAR VERSION OF FLOORING MATERIAL TO BUILD COVE AND BASE. COVE DETAIL FOR FLUSH TRANSITION TILE NO. SFS-16
CONCRETE, CMU, WALL BOARD, ETC. BACKER ROD AND FLEXIBLE JOINT SEALANT STRATASHIELD FLOORING EXISTING EXPANSION / ISOLATION EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITHOUT COVE NO. SFS-17
METAL OR PLASTIC COVE STRIP (OPTIONAL) CONCRETE, CMU, WALL BOARD, ETC. *BOND BREAKER SAW CUT AND FILL WITH FLEXIBLE SEALANT STRATASHIELD FLOOR TOPPING EXISTING EXPANSION / ISOLATION POLYETHYLENE BACKER ROD NOTE: *BOND BREAKER - EXCEED RECOAT WINDOW ON PRIMER 201, 222, 237, ETC. OR USE DUCT TAPE EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITH COVE NO. SFS-18
CONCRETE, CMU, WALL BOARD, ETC. METAL OR PLASTIC COVE STRIP (OPTIONAL) STRATASHIELD FLOOR TOPPING SAW CUT AND FILL WITH FLEXIBLE SEALANT EXISTING CONCRETE SUBSTRATE EXISTING EXPANSION / ISOLATION KEY IN WITH STRATASHIELD TOPPING 1/4 (6.35mm) TO 1/2 (12.7mm) DEEP POLYETHYLENE BACKER ROD (OPTIONAL) EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITH COVE NO. SFS-19
CONCRETE, CMU, WALL BOARD, ETC. METAL OR PLASTIC COVE STRIP (OPTIONAL) METAL OR PLASTIC TERMINATION STRIP STRATASHIELD FLOOR TOPPING EXISTING CONCRETE SUBSTRATE EXISTING EXPANSION / ISOLATION KEY IN WITH STRATASHIELD FLOOR TOPPING 1/4 (6.35mm) TO 1/2 (12.7mm) DEEP POLYETHYLENE BACKER ROD (OPTIONAL) EXPANSION/ISOLATION JOINT TREATMENT AT WALL/FLOOR INTERFACE FOR LAMINATE AND MORTAR S WITH COVE NO. SFS-20
CAST-IN-PLACE CIRCULAR FLOOR DRAIN CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MIN. 3" (76.2mm) STRATASHIELD FLOORING FLOOR DRAIN DETAIL WITHOUT SEALANT NO. SFS-21
CAST-IN-PLACE CIRCULAR FLOOR DRAIN CHIP CONCRETE BACK A MINIMUM OF 3 (76.2mm) FOR TRANSITION WITH A 1/2 (12.7mm) DEPTH. MIN. 3" (76.2mm) STRATASHIELD FLOORING FLEXIBLE JOINT SEALANT FLOOR DRAIN DETAIL WITH SEALANT NO. SFS-22
EXISTING PIPE OR SLEEVE 1-2 (25.4mm - 50.5mm) HEIGHT FLEXIBLE JOINT FILLER STRATASHIELD FLOORING BACKER ROD SLEEVED OR NON-SLEEVED PIPE PENETRATION IN FLOOR DETAIL NO. SFS-23