B. Provide fire-rated access doors where indicated or scheduled.

Similar documents
Construction Standards PAGE

A. Access doors and frames are part of an access door and frame allowance.

SECTION ACCESS DOORS AND FRAMES

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

SECTION ACCESS DOORS AND FRAMES

SECTION ACCESS PANELS

1. Include construction details, materials, individual components and profiles, and finishes.

Product Guide Specifications SECTION ACCESS DOORS/PANELS

where high efficiency is the standard

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

HOLLOW METAL DOORS AND FRAMES SECTION HOLLOW METAL DOORS AND FRAMES PART 1 - GENERAL

1. Bullet resistant hollow metal door and frame assemblies tested in accordance with UL 7 52 and in compliance with the following:

Maxam VANMET Access Doors Section ACCESS DOORS AND FRAMES Digicon Information Inc. Page 1

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

SECTION MISCELLANEOUS METALS

B. Related Sections: The following Sections contain requirements that relate to this Section:

SECTION ACCORDION FOLDING PARTITIONS

Access Doors Standard and Custom

B. Shop Drawings: For metal lockers. Include plans, elevations, sections, details, and attachments to other work.

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

e. Cutouts and Holes for Toilet Accessories: Made to template and edge-reinforced.

WHERE HIGH EFFICIENCY IS THE STANDARD

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

WHERE HIGH EFFICIENCY IS THE STANDARD

SECTION PERFORATED METAL. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION METAL STUDENT LOCKERS

PLASTIC LAMINATED FLOOR TO CEILING COMPARTMENTS SECTION FC TOILET PARTITIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION SOLID PLASTIC TOILET PARTITIONS. A. Section Includes: Toilet partitions and urinal screens, complete with hardware.

220 E. General Robinson St. Pittsburgh, PA fax

Construction Standards PAGE

TILEABLE. taccess.com.au ACCESS PANELS (TPM) Trafalgar has the most extensive range of access panels available:

PART 1 GENERAL HOLLOW METAL DOORS AND FRAMES

Direct Service Done Right. Access Doors + Panels Catalog

SECTION HOLLOW METALWORK. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

B. Surface, partition and recessed mounted toilet and bath accessories indicated on the Drawings and Schedules.

SECTION ALUMINUM HANDRAIL SYSTEMS

SOLID PLASTIC TOILET PARTITIONS. A. Section Includes: Toilet partitions and urinal screens, complete with hardware.

SECTION METAL DOORS & FRAMES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Access Doors. Complementary Building Products. Right to site.

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION WALL AND DOOR PROTECTION

HOTEL SPECIFICATION SECTION 08100

SECTION PLASTIC TOILET COMPARTMENTS

A NEW SCHOOL ATHENS BIBLE SCHOOL FOR THE PRESIDENT AND BOARD OF DIRECTORS ATHENS, ALABAMA

PLASTIC LAMINATED COMPARTMENTS SECTION TOILET PARTITIONS

SECTION METAL ATHLETIC LOCKERS

SECTION METAL ATHLETIC LOCKERS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

HDPE SOLID POLYMER-PLASTIC FLOOR TO CEILING COMPARTMENTS SECTION FC WEIS/POLY TOILET PARTITIONS

Soundmaster & Modernfold TECHNICAL DATA

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

SECTION TOILET AND BATH ACCESSORIES ADDENDUM NO.4

SECTION FIBERGLASS REINFORCED POLYESTER (FRP) DOORS AND ALUMINUM FRAMES

A. Minimum Thickness: Minimum thickness of base metal without coatings according to NAAMM-HMMA 803 or SDI A250.8.

SECTION METAL LOCKERS

1. Include plans, elevations, sections, details, and attachments to other work.

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

1. Standard two tier metal lockers and metal base.

SECTION DETAILS (MECHANICALLY ASSEMBLY)

Standard hollow metal doors frames. Minimum Thickness: Minimum thickness of base metal without coatings.

SECTION FOLDING ALUMINUM FRAMED WALL SYSTEM

DIVISION 10 SPECIALTIES SECTION METAL LOCKERS

SECTION GYPSUM BOARD PART 1 - GENERAL

A This Section includes stock, manufactured toilet compartments.

HDPE SOLID POLYMER-PLASTIC FLOOR BRACED COMPARTMENTS SECTION FB WEIS/POLY TOILET PARTITIONS

SECTION HOLLOW METAL DOORS AND FRAMES

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

COVER SHEET ELEVATION SHEET SECTION DETAILS (MECHANICALLY ASSEMBLY) SECTION DETAILS (WELDED ASSEMBLY)

SECTION PERSONNEL DUTY LOCKERS. 1. FPPL Series Police Personnel Duty Lockers, including the following:

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

H D P SOLID PHENOLIC CEILING HUNG COMPARTMENTS SECTION CH TOILET PARTITIONS

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

ACOUSTIC. taccess.com.au. METAL ACCESS PANELS (Rw34M) Trafalgar has the most extensive range of access panels available:

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

SECTION TOILET COMPARTMENTS SPEC WRITER NOTES:

Bullet Resistant Doors P/N BRD_

SECTION METAL EQUIPMENT LOCKERS

SECTION HOLLOW METAL DOORS AND FRAMES. A. Section includes steel doors and frames (hollow metal) indicated and as specified.

PIPE AND TUBE RAILINGS

SECTION HOLLOW METAL DOORS AND FRAMES

AD CAD Go to for the most current product specification sheets. ACCESS DOORS

1. Seismic Loads: Reference structural drawings.

C A R T E R W A T K I N S A S S O C I A T E S A R C H I T E C T S, I N C.

[PROJECT NAME] [PROJECT NUMBER] [CITY AND STATE]

DIVISION 8 OPENINGS SECTION HOLLOW METAL DOORS AND FRAMES

Spec. Standard: 07/25/ Revision: 01/31/14

Master Specifications for Microcotta November 2017

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION SECURITY PROTECTION PART 1 GENERAL

SECTION GYPSUM BOARD

.1 Underwriters' Laboratories of Canada (ULC)..1 CAN/ULC-S102-M88(R2000), Surface Burning Characteristics of Building Materials and Assemblies.

B. Hollow Metal work for Interior frames, including Glazing Stops.

American Metal Specialties, Inc.

Access Doors. Babcock-Davis Always right there.

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Galvanized System

Transcription:

SECTION 08305 ACCESS DOORS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.02 SUMMARY A. This Section includes access doors for installation in the following types of construction: 1. Gypsum drywall. 2. Masonry. B. Provide fire-rated access doors where indicated or scheduled. C. Building-in of anchors and grouting of frames set in masonry construction is specified in Division 4. D. Roof hatches are specified in Division 7. 1.03 SUBMITTALS A. Product data in form of manufacturer's technical data and installation instructions for each type of access door assembly, including setting drawings, templates, instructions, and directions for installation of anchorage, devices. 1. Include complete schedule, including types, general locations, sizes, wall and ceiling construction details, finishes, latching or locking provisions, and other data pertinent to installation. 1.04 QUALITY ASSURANCE A. Single-Source Responsibility: Obtain access doors for entire project from one source from a single manufacturer.

B. Fire-Resistance Ratings: Wherever a fire-resistance classification is indicated, provide access door assembly with panel door, frame, hinge, and latch from manufacturer listed in Underwriters Laboratories, Inc.'s "Building Materials Directory" for rating shown. 1. Provide UL label on each fire-rated access door. C. Coordination: Furnish inserts and anchoring devices that must be built into other work for installation of access doors. Coordinate delivery with other work to avoid delay. 1.05 PROJECT CONDITIONS A. Verification: Obtain specific locations and sizes for required access doors from trades requiring access to concealed equipment, and indicate on submittal schedule. PART 2 - PRODUCTS 2.01 MANUFACTURERS A. Manufacturers: Subject to compliance with requirements, provide access doors by one of the following: 1. Bar-Co., Inc. 2. J.L. Industries 3. Karp Associates, Inc. 4. Milcor, Inc. 5. Nystrom, Inc. 2.02 MATERIALS AND FABRICATION A. General: Furnish each access door assembly manufactured as an integral unit, complete with all parts, and ready for installation. B. Steel Access Doors and Frames: Fabricate units of continuous welded steel construction unless otherwise indicated. Grind welds smooth and flush with adjacent surfaces. Furnish attachment devices and fasteners of type required to secure access panels to types of support shown. 1. Frames: Fabricate from 16-gage steel.

a. Fabricate frame with exposed flange nominal 1-inch wide around perimeter of frame for units installed in the following construction: 1. Exposed masonry. 2. Ceramic tile finish. b. For gypsum drywall, furnish perforated frames with drywall bead. 2. For installation in masonry construction, furnish frames with adjustable metal masonry anchors. C. Flush Panel Doors (Typical): Fabricate from not less than 14-gage sheet steel, with concealed spring hinges or concealed continuous piano hinge set to open 175 degrees. Finish with manufacturer's factory-applied prime paint. D. Flush Panel Doors (Toilet Rooms): Fabricate from not less than 14-gage stainless steel sheet, with concealed spring hinges or concealed piano hinge set to open 175 degrees. Buff exposed surfaces to #4 satin finish. 1. For fire-rated units, provide manufacturer's standard insulated flush panel/doors, with continuous piano hinge and self-closing mechanism. E. Recessed Panel Doors: Fabricate from not less than 18-gage sheet steel with face of panel formed to provide recess below surface of applied finish. Reinforce panel as required to prevent buckling. Finish with manufacturer's factory-applied prime paint. systems. 1. Furnish recessed panels for concealed installation in drywall F. Locking Devices: Furnish flush, screwdriver-operated cam locks of number required to hold door in flush, smooth plane when closed. PART 3 - EXECUTION 1. Where shown or scheduled, provide one cylinder lock per access door. Furnish 2 keys per lock. Key all locks alike unless otherwise indicated. 2. For recessed panel doors, provide access sleeves for each locking device. Furnish plastic grommets and install in holes cut through finish.

3.01 INSTALLATION A. Comply with manufacturer's instructions for installation of access doors.

B. Coordinate installation with work of other trades. C. Set frames accurately in position and securely attach to supports with face panels plumb or level in relation to adjacent finish surfaces. 3.02 ADJUST AND CLEAN A. Adjust hardware and panels after installation for proper operation. B. Remove and replace panels or frames that are warped, bowed, or otherwise damaged. **END OF SECTION**