Pattern-Design Modified Bitumen Cap Sheets

Similar documents
MINERAL SURFACE CAP SHEET

Product Technical Bulletin SPM-4H-250

Product Technical Bulletin APS-5T

APPLICATION SAFETY TOOLS REQUIRED

REOXTHENE TECHNOLOGY BITULIGHT LINE -5 C WATERPROOFING MEMBRANE WITH REVOLUTIONARY TECHNOLOGY

Section 7 Waterproofing Roofing Standards

REOXTHENE TECHNOLOGY FLEXO-LIGHT SBS PROFESSIONAL LINE RANGE OF PRODUCTS FORMULATED AND DEVELOPED EXPRESSLY FOR ROOFING PROFESSIONALS -20 C

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

ELASTOFLEX SA P ELASTOFLEX SA P mineral

TEST PROCEDURE FOR NAIL-ON UNDERLAYMENT FOR USE IN DISCONTINUOUS ROOF SYSTEMS

ROOFING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR SELF-ADHERED UNDERLAYMENTS FOR USE IN DISCONTINUOUS ROOF SYSTEMS

REOXTHENE TECHNOLOGY EASY LIFT PROFESSIONAL LINE -10 C WATERPROOFING MEMBRANE WITH REVOLUTIONARY TECHNOLOGY WALL-FLOOR JUNCTION MEMBRANE

MECHANICALLY-FASTENED SBS SYSTEM

Polyglass SBS Roof Membranes. Performance You Can Count On

Henry Self-Adhering Roofing Underlayments. self-adhering. roofing underlayments DESIGNED FOR: Shingles. Tile. Metal. Slate

Roofing Material Specifications and Details

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

EVALUATION REPORT Boral Roofing /MonierLifetile 7575 Irvine Center Drive Suite 100 Irvine, CA

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

Firestone Asphalt Roofing Systems

Section Pre-Applied Sheet Membrane Waterproofing

PITTWRAP CW PLUS JACKETING Product Datasheet

CRCA Education Series. Self-Adhering Membrane Roofing Systems for Low Slope Roofs

Euroroof Flat Roofing Membranes

SBS Hot-Mopped & Cold Adhesive Roofing (COMGN289) Updated: 1/17

J&L Building Materials, Inc. Commercial Roofing

High performance solutions in waterproofing

1 inch. 1.5 inch. tamko.com

Mechanical Attachment of Separation Panels Hot Asphalt Attachment of Separation Panels

Sarnavap 5000E SA Vapour Control Layer

ASTM Volume 04.04, June 2017 Roofing and Waterproofing

nimaco

Pol-E-Base Modified Bitumen Roof System

Architectural Roof and Wall Products Guide Specifications

National Master Specification (NMS) Section SECTION INCLUDES.1 Materials and installation for modified bituminous roofing.

Miami-Dade County Certified Waterproofing System

SPECIFICATIONS FOR TENDER # SUPPLY OF EPS INSULATION AND MODIFIED BITUMEN ROOFING FOR WESTERN HEALTH

PITTWRAP HS (HEAT SEAL) JACKETING Product Datasheet

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

J41 Reinforced bitumen membrane roof coverings

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

SECTION ELASTOMERIC MEMBRANE ROOFING

SELF-ADHESIVE MEMBRANES

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

FORMCEAL 3000X WATERPROOFING SYSTEM

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

PRODUCT INFORMATION. 1/ Version #4

PERM-A-BARRIER NPS Detail Membrane

RESIDENTIAL ROOFING PRODUCT GUIDE

Weatherproofing & Sealing Systems

Architectural Roof Products Guide Specifications

SECTION BATTEN SEAM COPPER ROOFING

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

Peel & Seal Self-Stick Roofing Solutions

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

Sample Specification for the application of De Boer Duo HT 4 Slates/F C180 Two-Layer waterproof warm roofing membrane system to concrete.

MEMBRANES SELF-ADHERED. For Commercial And Residential Roofing Systems

EPDM ROOF RESTORATION

SDI-1000 Steel Deck - Insulated

Weatherproofing & Sealing Systems

Self-Adhesive Underlayments for Steep Slope Roof Systems POLYSTICK ROOF UNDERLAYMENTS

NURAPLY 3PT TECHNICAL DATA SHEET

Non-Residential Cool Roof Cost Summary

Design and Construction Standards SECTION MODIFIED BITUMEN ROOFING SYSTEM

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Typical waterproofing using Shelterseal 3000X

GUIDE SPECIFICATIONS SECTION ELASTOMERIC MODIFIED BUILT-UP ROOFING KLB-100 4P I CS ENERGY STAR APPROVED

A. This Section provides information regarding vapor permeable roof underlayment for the exterior roof.

Euroroof +44 (0)

Architectural Roof Products Guide Specifications

FORTIFIED Home High Wind. Bronze New Roof Requirements

Peel & Seal Self-Stick Roofing Solutions

PRODUCT DATA SHEET SARNAFIL S 327 ENERGYSMART ROOF MEMBRANE FELTBACK

Self-Adhered Underlayments for Steep Slope Roof Systems POLYSTICK ROOF UNDERLAYMENTS

FIRESTONE RUBBERGARD EPDM

D. Submit three sheet samples, approximately 8 inches x 10 inches, of base sheet and cap sheet.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Euroroof +44 (0)

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

SECTION 7307 CONCRETE/ CLAY TILE, METAL, SLATE AND ASPHALT COMPOSITION SELF-ADHERED/ PEEL & STICK ROOF UNDERLAYMENT

SECTION 7307 ASPHALT SHINGLE ROOF UNDERLAYMENT

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

SOLAR COATING SYSTEMS ACRYLIC RENOVATION ROOF 4.5. Specification for Built-Up Roofing SUMMARY

Roofing Underlayment Systems

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION Fiber Reinforced Stucco 1

INSTALLATION GUIDELINES PRECON

GUARANTEED ASPHALT LIMITED

MEMBRANES SELF-ADHERED. For Commercial And Residential Roofing Systems

LINE SOLO ALPAL TRAFIC. High performance SBS waterproofing. trusted by professionals

SECTION ASPHALT SHINGLE ROOFING SYSTEMS. Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text".

COLD GOLD TM FLIP BOOK. Roofing System COLD-APPLIED ROOFING SYSTEMS. FLASHING BOARD MEMBRANE CAP BASE COVER INSUL ATION VA PO R RETARDERS

UNDERLAYMENT PRODUCTS

ARCHITECTS & SPECIFIERS : SHINGLES, TILES, & ROOF COVERINGS

Transcription:

Exclusively Manufactured by BITEC, INC. Pattern-Design Modified Bitumen Cap Sheets Mineral Design and the various design patterns are produced under an exclusive manufacturing system covered by registered patents.

Pattern-Design Modified Bitumen Cap Sheets ROOF DESIGNS BY BITEC MINERAL DESIGN represents a premium product with unique mineral color patterns. Now designers, specifiers and property owners have a new instrument at their disposal for decorating roofs. The special membrane designs allow new and, until now, unforeseen possibilities. With MINERAL DESIGN, low slope and pitched roofs may be enhanced by designs of various contrasting colors, while providing excellent waterproofing qualities. MINERAL DESIGN is a new generation of BITEC modified bitumen membrane, that is self-protected with ceramic coated roofing granules. Using colored roofing granules in conjunction with a registered patent for the design application, numerous designs and color combinations are available for aesthetically pleasing roof applications. BITEC produces the MINERAL DESIGN products in both APP (atactic polypropylene) and SBS (styrene butadiene styrene) cap sheets to meet all application method requirements. MINERAL DESIGN is a waterproofing membrane manufactured to the highest quality standards imparted of BITEC, and will serve as a long-lasting waterproofing product, offering design and color to the finished roof. The advanced technical design, with a new composite reinforcement used in the manufacture of MINERAL DESIGN, offers protection from harmful ADVANTAGES New possibilities in roof decoration Excellent dimensional stability Improved elasticity Easy and fast to apply dimensional stability problems. MINERAL DESIGN's triple reinforcement spunbond polyester membrane will not warp or buckle, shrink or wrinkle. For MINERAL DESIGN applications, absolute dimensional stability before and after application is extremely important. For this reason, the membrane has a composite three-layer reinforcement, where the glass fiber is contained between two layers of continuous strand non-woven polyester fabric. Stability is provided by the glass fiber, and the bituminous mass is protected and reinforced by the non-woven polyester fabric. The dimensional stability of MINERAL DESIGN is very similar to that of glass fiber reinforced membranes, while maintaining good elasticity as in non-woven polyester fabrics. MINERAL DESIGN resists problems associated with incorrect storage and handling of rolls, (i.e., where left exposed to sun, or uneven torch-application of membrane, and application onto thermally resistant insulation) causing shrinkage and deformation 1. Upper surface: Mineral-coated polymer bitumen compound 2. First reinforcement layer: Continuous strand spunbond non-woven polyester fabric 3. Second reinforcement layer: Glass fiber 4. Third reinforcement layer: Continuous strand spunbond non-woven polyester fabric 5. Lower surface: Polymer bitumen compound

of membranes. MINERAL DESIGN also possesses excellent tear resistance making it suitable for mechanical attachment. MINERAL DESIGN is a special waterproofing product and must be treated as such. It differs greatly from traditional granule-surfaced membranes in that the granule surface provides a distinctive pattern, derived from granule placement on the membrane. As with any material having a pattern repeat, one must take care in applying, storing and handling this product. The exclusive MINERAL DESIGN patterns are manufactured to provide a constant, reliable design after application. MINERAL DESIGN membranes give the finished application a uniform appearance, provided that certain minimal application, storage, and handling techniques are followed. The installer must be aware that there will be a certain amount of waste generated by the pattern repeat, depending on the pattern selected for the project. The installer is solely responsible for determining the amount of material needed to successfully complete the project. APPROVAL CL A SS I F I E D U L R-13231 MEMBER: Membrane for Roofing Systems Classified By Underwriters Laboratories, Inc. As to an external fire exposure only 49S8 HANDLING AND STORAGE Successful application and a good finished appearance depend on careful handling and storage of the MINERAL DESIGN rolls. This is extremely important. All rolls must be stored on original factory pallets having a corrugated pad as a barrier to prevent marking of roll ends and possible distortion of the factory pattern. This corrugated pallet pad comes as a part of our standard factory packaging. Rolls must be stored on end with selvedge edge up, and never be left leaning or laying flat. All product must be stored away from direct sunlight and weather until shortly before use. Never double-stack pallets of Mineral Design. Should pallets of Mineral Design be stored outside, at the job site, the polyethylene shrinkwrap bag should be slit vertically, on all sides, to improve circulation and reduce product stress during warm weather. (Please refer to the BITEC Roofing Material Specifications and Details, Section 1.00 for more information, and the MINERAL DESIGN Technical Bulletin relative to product application and technical information.) Property located in Colorado

Circles and Squares Also available in CS 22-41 #CS 77-22 #CS 68-41 #CS 77-53 #CS 37-77 Rhombus Also available in R 22-41 #R 77-22 #R 68-41 #R 77-53 #R 37-77 Strip Slates #SS 76-71 #SS 53-51 #SS 77-53 #SS 22-41 Tiles #T 22-41 #T 68-41 #T 46-41 #T 76-71

BITUMEN TECHNOLOGY Oval Slates #OS 22-41 #OS 46-41 #OS 76-71 #OS 53-51 Bricks #B 22-77 #B 46-41 #B 22-41 Winding Fantasy #WF 22-41 #WF 77-22 #WF 76-71 Camouflage #C 4950 #C 76-71

Pattern-Design Modified Bitumen Cap Sheets APPLICATION It is essential that the installer be well-trained and fully understand the methods of application for the specific type of MINERAL DESIGN product being installed. Installation of this membrane should be performed only by a professional roofing contractor, well-trained in the methods described herein. BITEC, INC. produces this product within design tolerances, and is not responsible for improper or unsuccessful installation of this product. Each design has a specific pattern repeat, so in order to align the pattern and achieve maximum utilization of the roll, a certain portion of the repeat must be removed. The installer should expect to have a certain percentage of waste on each project. To help approximate the material needed, refer to the table on the right, showing each pattern s repeat length. You may have to remove up to 50% of this figure for alignment, depending upon the project requirement. Also, remember that you must provide a 6" minimum endlap. When cutting the membrane, it is recommended that the applicator use a straight-edge. Side lap alignment is essential to successfully complete the pattern. A 4.0" side lap is provided. Property located in Texas PAT T E R N R E P E AT Circles & Squares... 12.0" Tiles... 13.6" Strip Slates... 8.1" Winding Fantasy... 30.3" Oval Slates... 7.9" Rhombus... 12.0" Bricks... 3.5" Camouflage... 0.0" Proper Application temperature is essential. Regardless of the application method being used, the installer should produce a continuous, uninterrupted flow of bitumen or adhesive from all laps, not to exceed 1/8" to 1/4". Flow beyond this range will give unsightly results distorting the continuity of the pattern. Do not trowel the seams. For slopes greater than 3/4" in 12", blind-nailing the end laps is required to reduce the potential of membrane misalignment. The fastener used will depend on the substrate. Typically, blind nailing 6" to 9" o.c. is acceptable. Property located in Florida

It is the installer's responsibility to adhere to all safety precautions associated with application of polymer modified bitumen membranes, implementing and maintaining fall protection requirements and safety regulations. This applies to all low and steep slope applications. Property located in Colorado SPECIFICATIONS: MDA (APP Modified) ROLL SIZE 10 APPROVALS UL (R13231) UL (R13231) 302 F (150 C) 250 F (120 C) REINFORCEMENT Spunbond polyester composite Spunbond polyester composite PENETRATION 40 dmm @ 25 C 40 dmm @ 25 C <1 mm <1 mm COLD FLEXIBILITY (UNI-8202) +5 F (-15 C) -23 F (-30.1 C) WATER TIGHTNESS MD = 100 lbf/in MD = 105 lbf/in XMD = 100 lbf/in XMD = 105 lbf/in MD = 45% MD = 60% XMD = 45% XMD = 60% MD = 40,012 n MD = 56,048 n XMD = 40,012 n XMD = 56,048 n 4 mm 4 mm 107 lbs 107 lbs 97 ft2 97 ft2 107.6 ft2 107.6 ft2 SOFTENING POINT SLIDE (ASTM D-36) (ASTM D5) (UNI-8202) (CGSB 37-GP-56M) DYNAMIC PUNCTURE STATIC PUNCTURE (CGSB 37-GP-56M) TENSILE STRENGTH ELONGATION (CGSB 37-GP-56M) (ASTM D-412) (ASTM D412) LOAD STRAIN PRODUCT (CGSB 37-GP-56M) THICKNESS ROLL WEIGHT, COVERAGE, APPROX. INSTALLED APPROX. TOTAL SURFACE AREA, APPROX. m2 MDS (SBS Modified) 10 m2

M i n e r a l D e s i g n C o l o r s 37 Green 76 Gray 22 Red 68 Buff 41 Brown 53 Black 4950 Buff 46 Brown 71 Gray 77 Gray 65 Buff 51 Black The mineral granule colors shown throughout this brochure are reproduced as a reference only, and as an aid in the selection of contrasting color schemes. Actual product color may vary slightly from those shown. BITEC, INC. assumes no responsibility for any such color variance as shown versus the actual color. The purchaser should view the actual available colors at their local BITEC distributor, or contact their local BITEC representative. Wa r r a n t y I n f o r m at i o n Mineral Design can be installed on all typical roof slopes, both commercial and residential: For commercial applications our standard warranties apply: 10 and 12 Yr. Limited Material Warranties are available for commercial applications: Ten Year Limited Material Warranty Twelve Year Limited Material Warranty Limited Insured Roofing Warranty Our Limited Insured Roofing Warranty is available in coverage periods of 10, 12, 15, and 20 years. This warranty is only available through our network of Authorized Applicators. For residential applications, (i.e., single and multiple family dwellings) our Mineral Design Twenty-five Year Limited Residential Roofing Membrane Warranty is available. This warranty can be obtained by anyone purchasing Mineral Design membranes. However, roof slope must be 3" in 12" to qualify for this warranty. For slopes of less than 3" in 12", our Limited Material Warranty applies. Revision #5, November 2007 Visit our web site at www.bi-tec.com Manufacturers of Advanced Technology Waterproofing Membranes P.O. Box 497 No. 2 Industrial Park Drive Morrilton, Arkansas 72110 Fax (501) 354-3019 Phone 1-800-535-8597