COLIFORM FILTERS. All filters listed on this page are white with black grids, 47 mm diameter, sterile.

Similar documents
MicroFunnel Filter Funnels

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

Microfil Filtration System

Qualitative Filter Papers

Standard Operating Procedure for the Sampling and Analysis of Total Suspended Solids in Great Lakes Waters

SOP-C-109 Determination of Filterable Residue

Filtration. Filter Papers, Microfibre filters, Extraction Thimbles, Micro Filtration, Syringe Filters

LABORATORY FILTER PAPER

Heterotrophic Bacteria

INTERNATIONAL STANDARD

Total Suspended Solids by Gravimetric Determination

Extraction Products Separator Paper 188 Solid Phase Extraction (SPE) 189 Extraction Thimbles 192. Extraction Products

Microfil Filtration System

FILTERS (GLASS FIBER)

2. 47 mm grid marked, white sterile 0.45 micron membranes (Millipore or equivalent) 4. Vacuum pump capable of inches of vacuum

Method 9.2 Drinking water and effluent: bacteria by the membrane filter method

Dry matter content and fibre content

1. Low profile units 2 Normal profile sterilisation filter units 3. Each pack includes 12 glass-fibre prefilters

EXPERIMENT 3 SOLIDS DETERMINATION

Gravimetric Analysis: Determination of % Sulfur in Fertilizer

3.0 DETECTION LIMIT 3.1. See Procedure ALQAP Procedure for the Determination of Uncertainty

Basic Filtration Table of Contents

Laboratory products catalog.

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

Cell Culture Products LABORATORY GLASSWARE

Filter Papers and Membranes Cellulose Filters 4 Glass Microfiber Filters 22 Membrane Filters 65. Filter Papers and Membranes

NYLON SYRINGE FILTERS

Hamilton PRP Polymeric Columns

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

PREFILTERS/DEPTH TYPE M EDIA

LABORATORY FILTRATION CATALOG

Ensure high performance chromatography by using particle free mobile phases and sample solutions

Fines fraction of paper stock by wet screening

SOUTH AFRICAN NATIONAL STANDARD

Total Dissolved Solids by Gravimetric Determination

EZ-Fit Filtration Units Ready-to-use sterilized filtration devices for microbial enumeration

SOP-C-107 Determination of Non Filterable Residue

Settling Column Test Procedures (modified October 2002)

Synchronized solutions for food and beverage testing

Polysep II Filters. Superior filters provide multiple filtration stages in a single compact configuration for critical prefiltration applications

FLUID CLEANLINESS OIL FILTRATION

Advantec MFS. Filtration Products

Built for Better Testing. EZ-Fit Filtration Units: Convenience without compromise. Data Sheet

METHOD 17 - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM STATIONARY SOURCES. NOTE: This method does not include all of the

Coliforms, Total and E. coli

VISCOSITY, INHERENT (One Point)

Environmental Express. Joe Boyd. Solids and BOD Analyses: Pitfalls and Troubleshooting

Stream Ecology Lab Module 4/5 Determining Discharge and Sediment Yield in a Small Stream

Synchronised solutions for cell culture

ENGI Environmental Laboratory. Lab #2. Solids Determination. Faculty of Engineering & Applied Science

Total Dissolved Solids Dried at 180ºC. Total Volatile Dissolved Solids at 550 C

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

SINTERED GLASSWARE Porosity Grades and their General Use

Color, True and Apparent, LR

Company Standard THIS DOCUMENT IS INTENDED TO BE USED BY BOTH EXTERNAL SUPPLIERS AND NIFTYLIFT INTERNAL QUALITY DEPARTMENT.

D.9 Particulate Nitrogen and Particulate Carbon

High Purity Pleated Depth & Membrane Cartridges

Scope and application: For water and wastewater. Turbid samples are filtered during the analysis.

Monitoring the quality of beverages, water and foods...

Proper Selection of a Crossflow Filter

Improving Sampling Techniques for the Analysis of Lead in Groundwater: Determining Optimal Filtration Conditions. Contract Number: SR00-055

BOD/CBOD, TSS ph OPERATOR BASICS. Presented by: Marcy Bolek - Alloway

NC DENR/DWQ WASTEWATER/GROUNDWATER LABORATORY CERTIFICATION

Membrane Solutions is manufacturer

SECTION D.3 CHLOROPHYLL AND PHEOPHYTIN

Analysis of Calcium Carbonate Tablets

Laboratory filtration

Laboratory filtration

SYRINGE FILTERS. New Filter Housing Design. Phenex. Old. New. For HPLC and GC sample and solvent filtration. Improved Performance Benefits:

Critical Environment Products and Services

Milligard Filters. Superior filters for critical prefiltration applications. Benefits. Data Sheet. Data Sheet

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

THE CLEAR ADVANTAGE. INNOVATIVE FILTERS FOR process and potable water

FILTRATION QUANTITATIVE ASHLESS FILTER PAPER QUALITATIVE FILTER PAPER GENERAL PURPOSE FILTER PAPER GLASS MICROFIBER QUARTZ MICROFIBER

DETERMINING MOISTURE CONTENT OF BITUMINOUS MIXTURES

Air monitoring around the world.

Filtration Products. Best Value Guaranteed Product Quality Innovation to Benefit Customers

Analytical Method for aldrin, endrin and dieldrin (Targeted to Agricultural, Animal and Fishery Products)

General Protocol. Solutions.

Blooming prospects. Ways to improve your painting results

Synchronized solutions for quality control

DECLARATION OF COMPLIANCE Ultipor N66 Filter Cartridges

Plastic Storage Bottles Product Selection Guide

METHOD 5A - DETERMINATION OF PARTICULATE MATTER EMISSIONS FROM THE ASPHALT PROCESSING AND ASPHALT ROOFING INDUSTRY

innovating refining defining

innovating refining defining

This is more than providing you with containers This is a relationship. We re here for you. We built it to last. We mean it. Here s your guarantee.

DAIRY WATERS. (Coliform Group and Escherichia coli) [E. coli verification required only on source water] IMS #24

2. Crystallization. A. Background

Fertilizer Urea - Specification

Procedures for Operation of the SPEX 8150 Shatterbox for preparation of powders for analysis

NH3 Sampling Protocol Using The Ogawa Sampler*

Preparation. Sample. Extraction Glassware Liquid/Liquid Extraction SUPELCO

ort No. 925 Proficiency Testin Roun - Total Solids, Total Suspendedd Solids, Dissolved Solids - August 2015

Compressed Air Filters 1/4 and 1/2 Line Size Filters

Water supplied by Marafiq does not meet the process requirements.

2 Chemicals, Apparatus and Unit Operations of Analytical Chemistry

EPK- EasyTest Patch Test Kit Manual

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1122 DETERMINING SULFATE CONTENT IN SOILS. July 17, 2015

Top Tips for Conducting DMR-QA Analyses Waters Corporation 1

Transcription:

COLIFORM FILTERS Which filters do I use for Fecal coliforms, and which do I use for Total coliforms? According to the 22 nd edition of Standard Methods, Procedure 9222B (Total Coliform MF-Procedure) and Procedure 9222D (Fecal Coliform MF-Procedure): Use only those membrane filters that have been found through adequate quality control testing and certification by the manufacturer, to exhibit full retention of the organisms to be cultivated (emphasis added by us). All of the manufacturers for the grid filters listed in this catalog said they have written statements that certify their filters conform to the requirements of Standard Methods. However, the certification does not mention any specific organisms. So apparently, they do not certify their filters specifically for fecal or total coliforms. Numerous telephone calls to each of them have not resulted in clarification of this question. Millipore spokesmen stated that their type HCWG (pore size=0.7 µm, NCL# FM-150) is recommended for fecal coliforms, and that their type HAWG (pore size=0.45 µm, NCL# FM-151) is recommended for total coliforms. This runs contrary to the conventional wisdom of using the 0.45 µm pore size for fecal coliforms, but Millipore has confirmed this on several occasions. We do not have this in writing. The other manufacturers have informed us verbally that their grid filters are acceptable for both fecal and total coliforms, but will not state this in writing. All filters listed on this page are white with black grids, 47 mm diameter, sterile. Following is a list of grid filters which we stock. The main differences are in packaging, and whether pads are included. GRID FILTERS ONLY (NO PADS) Brand Manufacturer # Pore Size Description NCL # Price Pall 66068 0.45 µm FG-680B 154.00/pk of 200 NCL FG-690 0.45 µm FG-690 86.50/pk of 200 NCL FG-690 0.45 µm FG-690B 390.40/cs of 1000 Millipore HCWG047S6 0.70 µm FM-150 75.40/pk of 150 Individually wrapped, Millipore HCWG047S6 0.70 µm FM-150B 274.40/cs of 600 sterile Millipore HAWG047S6 0.45 µm FM-151 66.00/pk of 150 Millipore HAWG047S6 0.45 µm FM-151B 240.10/cs of 600 Advantec A045H047A 0.45 µm FM-454A 46.25/pk of 100 Advantec A045H047W 0.45 µm FM-454B 288.95/cs of 1000 GRID FILTERS WITH PADS Brand Manufacturer # Pore Size Description NCL # Price Whatman 7141-104 0.45 µm 100 individual bags, each containing one filter & one pad FW-999 91.55/pk of 100

Whatman GLASS FIBER FILTERS WHATMAN GRADE 934-AH GLASS FIBER FILTERS Grade 934-AH is approved by Standard Methods and will work for both Total Suspended Solids and Volatile Solids. Retention size: 1.5 microns. Packs of 100 circles. Diameter (cm) NCL # Price/pk 2.1 F-93421 25.80 2.4 F-93424 25.90 3.2 F-93432 33.35 3.5 F-93435 37.65 3.7 F-93437 37.65 4.25 F-93442 40.85 4.7 F-93447 46.05 5.5 F-93455 47.95 7.0 F-93470 67.75 9.0 F-93490 100.75 11.0 F-93411 113.20 12.5 F-93412 154.80 NCL GRADE 934-AH GLASS FIBER FILTERS 934-AH is a registered trademark of Whatman, Inc. The following Glass Fiber Filters are approved by Standard Methods and will work for both Total Suspended Solids and Volatile Solids. Retention size: 1.5 microns. Packs of 100 circles. 2.1 FN-93421 20.35 2.4 FN-93424 21.00 3.2 FN-93432 26.30 3.7 FN-93437 29.70 4.25 FN-93442 35.55 4.7 FN-93447 39.75 5.5 FN-93455 42.50 7.0 FN-93470 55.95 9.0 FN-93490 75.50 11.0 FN-93411 107.75 12.5 FN-93412 133.80 15.0 FN-93415 170.20 18.5 FN-93418 255.00

GLASS FIBER FILTERS PRE-WASHED, PRE-WEIGHED FILTERS Whatman 934-AH, one of the most widely used filters for Total Suspended Solids analysis, is now available in a time-saving, Ready-To-Use (RTU) format: pre-washed and pre-weighed. Each RTU filter is packaged within an aluminum pan with the filter weight clearly printed on a heat resistant label. The 934-AH RTU meets the requirements under the latest edition of Standard Methods 2540D. 100 per pack. Each pre-treated filter comes in an aluminum pan with the filter weight clearly noted. First, place the 934-AH RTU on the funnel of the vacuum filtration apparatus and seal the filter to the funnel by wetting with a small amount of water. Then, filter your sample. Finally, wash the filter with three aliquots of 10 ml reagent grade water. Remove the filter, return it to the aluminum weigh pan and dry it to constant weight at 103 C to 105 C. To obtain the weight of total suspended solids, subtract the weight of the filter indicated on the pan label from the final weight. 4.25 RTU-93442 109.65 4.7 RTU-93447 91.40 5.5 RTU-93455 101.05 Order Toll Free 1.800.648.7836 www.nclabs.com

GLASS FIBER FILTERS The following Glass Fiber Filters are approved by Standard Methods and will work for Total Suspended Solids. NCL GRADE A-E GLASS MICROFIBER FILTERS Save money on your Grade A-E glass fiber filters by buying NCL brand instead of the other guy s. Guaranteed to be absolutely the same in particle retention, size, and performance. These filters meet the requirements for TSS testing as defined in Standard Methods. Retention size: 1.5 microns; 100 circles/pack. 2.1 AE-21 18.45 2.4 AE-24 18.45 2.5 AE-25 18.45 3.2 AE-32 18.75 3.7 AE-37 19.75 4.25 AE-42 32.35 4.7 AE-47 32.85 5.5 AE-55 33.65 7.0 AE-70 49.40 9.0 AE-90 51.45 10.2 AE-102 68.10 11.0 AE-110 73.95 12.5 AE-125 105.60 PREWASHED FILTERS Many of you have requested these. As you know Standard Methods requires you to wash and dry TSS filters until they are of constant weight. This takes time and time is money. Prewashed filters are vacuum rinsed with 3 aliquots of deionized water. This step removes any loose fibers which could affect the filters constant weight. The filters are then dried at 105 C, cooled and desiccated for 24 hours. For those of you willing to spend the extra money, we offer these as follows. All are grade 934-AH. Retention size: 1.5 microns; packs of 100. 4.7 PWF-47 67.55 9.0 PWF-90 88.00 MILLIPORE GLASS FIBER FILTERS AP40-047-05. Glass fiber filters without binder. Retains structural integrity without weight loss when ignited at 550 C. 47 mm diameter. Packs of 500. FM-147 299.00/pk

GLASS FIBER FILTERS, FILTER PAPER The following Glass Fiber Filters are not mentioned by Standard Methods. OTHER WHATMAN GLASS FIBER FILTERS Listed below are the most popular sizes and grades. Please call if you don t see what you need. Diameter (cm) Type NCL # Price/pk 15.0 2V FF FF-215 74.50/100 18.5 Grade 3 FW-318 59.00/100 2.1 GF/A F-499 33.75/100 3.7 GF/A F-500 38.00/100 4.25 GF/A F-503 40.55/100 4.7 GF/A F-505 44.95/100 5.5 GF/A F-510 47.15/100 9.0 GF/A F-520 85.55/100 4.25 GF/B F-521 81.00/100 4.7 GF/B F-522 104.00/100 9.0 GF/B F-524 48.20/25 11.0 GF/B F-523 54.25/25 Diameter (cm) Type NCL # Price/pk 2.4 GF/C F-526 66.65/100 4.25 GF/C F-532 76.30/100 4.7 GF/C F-533 101.05/100 5.5 GF/C F-534 120.40/100 9.0 GF/C F-536 182.75/100 2.1 GF/D F-539 38.75/100 2.4 GF/D F-540 38.75/100 3.5 GF/D F-542 44.30/100 4.7 GF/D F-545 57.60/100 9.0 GF/D F-550 38.75/25 11.0 GF/D F-551 52.05/25 QUANTITATIVE FILTER PAPER MFS quantitative alpha cotton cellulose, acid washed, rinsed with ultrapure water to neutralize. Ash content 0.01% for fine particulates (<5 µm). 12.5 FM-5C12 32.00/100 18.5 FM-5C18 59.65/100 Order Toll Free 1.800.648.7836 www.nclabs.com

WHATMAN #1: Qualitative, medium to fast speed. Retention size: 11 microns. 7.0 FW-107 10.15 9.0 FW-109 12.70 11.0 FW-111 15.15 12.5 FW-112 15.75 15.0 FW-115 22.70 18.5 FW-118 31.65 24.0 FW-124 50.55 WHATMAN #2: Qualitative, medium speed. Retention size: 8 microns. 7.0 FW-207 13.95 9.0 FW-209 16.50 11.0 FW-211 16.75 12.5 FW-212 20.25 15.0 FW-215 26.50 18.5 FW-218 35.80 WHATMAN #4: Qualitative, fast speed. Retention size: 25 microns. 7.0 FW-407 11.40 9.0 FW-409 13.95 11.0 FW-411 17.70 12.5 FW-412 22.70 15.0 FW-415 29.10 18.5 FW-418 43.00 WHATMAN #5: Slow speed. Retention size: 2.5 microns. 7.0 FW-507 13.50 9.0 FW-509 17.20 11.0 FW-511 22.05 12.5 FW-512 28.20 15.0 FW-515 40.55 FILTER PAPER WHATMAN #40: Ashless, medium speed. Retention size: 8 microns. 7.0 FW-4007 29.10 9.0 FW-4009 40.45 11.0 FW-4011 48.00 12.5 FW-4012 54.35 15.0 FW-4015 72.10 18.5 FW-4018 106.15 24.0 FW-4024 168.60 WHATMAN #41: Ashless, fast speed. Retention size: 25 microns. 7.0 FW-4107 29.05 9.0 FW-4109 38.00 11.0 FW-4111 45.55 12.5 FW-4112 53.15 15.0 FW-4115 72.10 WHATMAN #42: Ashless, slow speed. Retention size: 2.5 microns. 7.0 FW-4207 30.30 9.0 FW-4209 40.40 11.0 FW-4211 49.35 12.5 FW-4212 56.90 15.0 FW-4215 72.10 WHATMAN #541: Hardened, ashless, fast speed. Retention size: 25 microns. 7.0 FW-54107 31.65 9.0 FW-54109 41.70 11.0 FW-54111 47.25 12.5 FW-54112 56.90 15.0 FW-54115 91.00 WHATMAN GRADE 1PS PHASE SEPARATION FILTER PAPER For filtering water-solvent extractions, such as in the Oil & Grease procedure. 11.0 FW-1PS11 55.90 12.5 FW-1PS12 69.25 15.0 FW-1PS15 89.95

FILTER DISPENSER, FILTER FUNNELS EZ-PAK DISPENSER AND MEMBRANES Dispense sterile membranes immediately with contamination-free and hands-free convenience. The EZ-Pak System revolutionized filter handling by combining the benefits of ready-to-use, sterile, individually-packed membranes with a unique dispenser. By simply depressing the dispenser s lever, the sterile membrane is unwrapped from its package for easy access. EZ-100 1449.00/ea EZ-PAK GRIDDED MEMBRANE FILTERS MILLIPORE #EZHAWG474 47 mm diameter, 0.45 µm pore size, 600 filters per pack. EZ-474 350.00/pk DISPOSABLE FILTER FUNNELS WITH RECEIVER BASE Sterile, individually wrapped, 150 ml graduated filter funnel with receiver. Includes 47 mm membrane filter. After filtering the sample, upper section twists off for easy removal of membrane filter. For use in coliform determinations where autoclaving is not an option. Pore Size Membrane NCL # Price/cs 0.2 µm Plain FN-120 555.90/72 0.45 µm Gridded FN-130 555.90/72 DISPOSABLE FILTER FUNNELS Sterile, individually wrapped graduated funnel with 47 mm, 0.45 µm, gridded membrane filter. Each case includes 50 funnels and 6 funnel adapters (for use with NCL# R-777, rubber stopper). After filtering the sample, upper section twists off for easy removal of membrane filter. Funnel Size NCL # Price/cs 100 ml FN-145A 233.60 250 ml FN-145B 259.90 Order Toll Free 1.800.648.7836 www.nclabs.com

FILTER FUNNELS MAGNETIC FILTER FUNNEL Unbreakable polysulfone 300 ml funnel body accommodates 47 mm (4.7 cm) filters. Comes with rubber stopper to fit 1000 or 2000 ml suction flasks, or can be used with a filtration manifold. FG-710 269.00/ea Replacement screen for above KIMBLE GLASS FILTER FUNNEL ASSEMBLY Heavy duty glass microfiltration assemblies. Available in two filter sizes: 47 mm and 90 mm (for larger volumes). For vacuum filtrations. Each assembly consists of a graduated glass funnel, fritted glass support base, anodized aluminum clamp, and silicone stopper. (see picture of assembled product and breakdown showing components A through D) Complete assembly for 47 mm filters. Funnel size: 300 ml FK-937 179.75/ea FG-710C 30.00/ea Complete assembly for 90 mm filters. Funnel size: 1000 ml FK-953 626.40/ea A C B D REPLACEMENT PARTS FOR KIMBLE 300 ML FILTER FUNNEL ASSEMBLY Description NCL # Price/ea glass funnel, 47 mm, 300 ml FK-937A 73.45 glass support base FK-937B 108.65 clamp FK-937C 91.75 silicone stopper with hole FK-937D 21.90 REPLACEMENT PARTS FOR KIMBLE 1000 ML FILTER FUNNEL ASSEMBLY Description NCL # Price/ea glass funnel, 90 mm, 1000 ml FK-953A 176.30 glass support base FK-953B 306.75 clamp FK-953C 139.65 silicone stopper with hole FK-953D 19.90

FILTER FUNNELS MFS GLASS FILTER FUNNEL ASSEMBLY Supplied with stainless steel screen support base, 300 ml graduated funnel, anodized aluminum clamp, and #8 silicone stopper. FS-315 229.95/ea MFS POLYSULFONE FILTER FUNNELS 300 ml graduated polysulfone funnel with recessed filter support to provide sufficient clearance so it will not twist or tear membrane filter. Comes with #8 stopper to fit 1000 ml suction flasks or MFS vacuum manifold. For use with 47 mm filters. Funnel top locks onto base with 1 /4 turn. Probably not as nice as the magnetic version, but a lot cheaper! FS-5010 69.15/ea Order Toll Free 1.800.648.7836 www.nclabs.com