OEM WHEEL EQUIPMENT ENTHALPY RECOVERY WHEELS INDOOR AIR QUALITY VENTILATION ENERGY RECOVERY

Similar documents
OEM WHEEL EQUIPMENT ENTHALPY RECOVERY WHEELS INDOOR AIR QUALITY VENTILATION ENERGY RECOVERY

IMPACT OF THE SEMCO ANTI-STICK FACE COATING ON THE COLLECTION AND CLEANING OF ENVIRONMENTAL TOBACCO SMOKE FROM THE WHEEL SURFACE RESEARCH FINDINGS

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

SECTION AIR-TO-AIR ENERGY RECOVERY EQUIPMENT

GATES-HILLMAN CENTERS

Independent Performance Verification of SEMCO s Total Energy Recovery Wheels

A Paradigm Shift in ERV Technology. Paul Ehrlich, PE President Building Intelligence Group PLLC

Next Generation: High Efficiency Energy Recovery Ventilator (ERV) 11/14/11 Dais Analytic Corporation

tˆ Š u ˆ m ˆ œ ˆ Ÿˆ Œ ˆ cˆ Œ Œˆ ˆ Œ Œˆ Ÿˆ Â

COMPARING THE ANTIMICROBIAL ACTIVITY OF THE SEMCO 3A TOTAL ENERGY WHEEL WITH OTHER SELECTED ANTIMICROBIAL SURFACE TREATMENTS RESEARCH FINDINGS

The Case for Energy Recovery in addressing Commercial Building Indoor Air Quality

Valent Packaged Rooftop Units A Fresh Choice for High-Percentage Outdoor Air Designs. Valent is a business of Unison Comfort Technologies.

Airxchange Catalog Contents

When you need more than just Ventilation!

APPLICATIONS Air-to-Air Energy Recovery

Rebel commercial packaged rooftop systems

Rebel commercial packaged rooftop systems

EVALUATION SUBJECT: THE UNICO SYSTEM SMALL- DUCT, HIGH-VELOCITY HEATING AND COOLING SYSTEMS

TDPs provide you with new technical training materials designed to help your contractors, engineers, and designers to effectively design, specify,

HIGH EFFECTIVENESS ENERGY RECOVERY

Mechanical Product Overview

Georgetown University New Science Center

2. The requirements of Sections 502, 503, 504 and 505. In addition, commercial buildings shall comply with either Section 506.2, or

ENGINEERING UPDATE JULY VOLUME 11 THIS PACKAGE INCLUDES A COLLECTION OF ARTICLES FROM VOLUME 11 OF THE JULY 2013 ENGINEERING UPDATE.

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

EXPERIENCE THE AIRXCHANGE ADVANTAGE

Changes to the Minnesota Commercial Energy Code. Presented by: Andy Thielen, PE

South Jefferson High School Huyett Road Charles Town, WV 25414

A Primer on Recovery Efficiency Ratio

Depth: Mechanical Redesign

Rooftops High performance, proven reliability and easy installation

Price High Performance Horizontal Fan Coil Units

Level 1 Modules tdp-101 hvac industry overview tdp-103 concepts of air conditioning tdp-102 abcs of comfort

EES Energy Efficient Systems Rotary Screw Air Compressors kw Horsepower

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

2015 International Mechanical Code Errata (Portions of text and tables not shown are unaffected by the errata)

ENERGY CONSERVATION STRATEGIES FOR HVAC SYSTEMS

Ceiling Radiant Cooling Panels

Price Fan Powered Terminal Units

Mechanical Depth. Redesign and Analysis

Energy Recovery Ventilation & ERV Basics The New Custom Express Tool

Ceiling Radiant Cooling Panels

Voyager kw rooftop units Plug and Play comfort in commercial applications

Energy Recovery Ventilation Equipment

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1.

Technical Development Program

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6)

OUTDOOR AIR, HEAT WHEELS AND JCPENNEY: A NEW APPROACH TO RETAIL VENTILATION

ENERGY RECOVERY IN MINNESOTA:

IN THIS ISSUE INTRODUCTION BACKGROUND. March 2018 High Humidity in Winter: Analysis for Multi-Family Passive House Projects

RETROFIT SOLUTIONS. For Gas Turbines And Rotating Machinery

Division 23 - HVAC Section Switzerland Beallsville K-12 DEDICATED OUTSIDE AIR HANDLING UNIT WITH DESSICANT WHEEL

Outdoor air treatment units

Nexus Modular Hybrid Cooler BENEFITS

Thesis Proposal. Clemson University Advanced Material Research Laboratory Anderson, SC. David Anderson Mechanical Option. Photo by Fred Martin

An all-in-one system that combines the advantages of Kingspan KoolDuct with the durability of Techna-Duc, and is suitable for indoor and outdoor

SECTION EXHAUST FANS PART 1 GENERAL

Performance Rating of Air-to-Air Exchangers for Energy Recovery Ventilation Equipment

INNOVATIONS IN VENTILATION TECHNOLOGY 21ST ANNUAL INTERNATIONAL AIVC CONFERENCE THE HAGUE, NETHERLANDS, SEPTEMBER 2000

Space Conditioning Systems, Ducts, and Fans (Page 1 of 6))

GUIDE SPECIFICATION: DUCT LINER

High-Performance Schools

EnergyPro Building Energy Analysis. Single-story School Building

Accessories & Options. For Terminal Units

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

Good indoor air quality (IAQ) management has become paramount in the construction industry as study

Calculating the Efficiency of Energy Recovery Ventilation and its Effect on Efficiency and Sizing of Building HVAC Systems

ARMSTRONG DESIGN ENVELOPE FAQ

Energy Recovery Process Cooling Example. Presentation - Overview. Air Change Australia Pty Ltd. Air Change Energy Recovery Range

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

Trane Water-Source Variable Refrigerant Flow

LEED. Leadership in Energy and Environmental Design

Energy Recovery: Rotary Heat Exchanger. Rotary Heat Exchanger (Enthalpy Wheel) Schematics

2-Pipe fan coil terminal units were selected as the parallel system to handle the remaining sensible cooling load.

Below is a brief description of heat/energy-recovery ventilators and other terms as relevant to ENERGY STAR.

1.02 Related Sections A. Section Heating, Ventilation and Air Conditioning (HVAC). C. Section Pneumatic and Electric Control HVAC.

Control Strategies Affected by Changes to 90.1

Price Single Duct Terminal Units

Implementing Demand Controlled Ventilation to Meet ASHRAE Standard By KlasC. Haglid, P.E., R.A., CEM

ROOF TOP SPACE. SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA C

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

BETTER ENVIRONMENT BEST INDOOR AIR QUALITY DUO-CLEAN ERV & HRV CORE.

Large University Central Chiller Plant Design Considerations

SECTION AIR TERMINAL UNITS

Technical Report Three Mechanical Systems Existing Conditions Evaluation

Mechanical Technical Report Three Mechanical Systems Existing Conditions Evaluation

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

MEP's Letter of Assurance

1. ARI 410 Standard for chilled water, hot water and steam coils. 2. ARI 430 Central Station Air Handling Units

SECTION AIR COILS

SECTION COOLING TOWER

Energy Recovery Systems. Greg Drensky Vice President Jacco & Associates

WEST VIRGINIA UNIVERSITY ALUMNI CENTER Morgantown, West Virginia

Terminal. 3 Las Vegas, NV. Technical

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.

How to Reduce Energy Use in Your Labs by Up to 50%

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

IAQ & Energy Impact of Exhaust Air Transfer Ratio

FRP Fans Blow Away the Competition in Corrosive Applications

Evaluating Variable Air Volume (VAV) Packaged Rooftop Systems for Use in High Performance Environments

Transcription:

INDOOR AIR QUALITY VENTILATION ENERGY RECOVERY OEM WHEEL EQUIPMENT ENTHALPY RECOVERY WHEELS

AHRI certified & independently tested wheel performance Highest effectiveness and Recovery Efficiency Ratio (RER) Reliable operation and long life expectancy backed by 30 years of proven product performance SEMCO fluted transfer media which provides true laminar flow and self-cleaning capability ENVIRONMENT ECONOMICAL EXPERTISE Use of the AHRI Certified mark indicates a manufacturer s participation in the certification program. For verification of certification for individual products, go to www.ahrinet.org. 2

OEM WHEEL EQUIPMENT THE SEMCO 3A TECHNOLOGY OFFERS A NUMBER OF BENEFITS Independently tested & AHRI certified wheel performance High latent AND sensible heat transfer efficiencies Highest Recovery Efficiency Ratios (RER) available Industry Leading indoor air quality device through minimized desiccant cross contamination Integrated purge section option Wheel independently certified to pass NFPA 90A requirements for flame spread and smoke generation and ASTM E84 fire test method High Enthalpy Performance = Less Pressure Loss, Less Fan Energy, More Energy Savings, Low operating costs Low maintenance wheel media saves time and money with improved performance We offer a wide selection of OEM desiccant wheel products and systems that can increase the performance of a variety of energy recovery products. Our OEM products offer the highest performance, maintain the lowest operating cost and can be installed in a broad range of applications, such as: Schools, universities, dormitories Offices, condominiums, apartments Smoking lounges, casinos Hospitals, nursing homes, day care centers Hotels, motels, department stores Clean rooms, circuit board, chip manufacturing Sports arenas Convention centers, airports, prisons Bus and train maintenance facilities Welding, foundry, casting areas Printing operations All humidity controlled spaces Breweries 3

WHY OUR PRODUCTS MAKE YOUR SYSTEMS BETTER REASON 1: We deliver high total recovery effectiveness with low parasitic pressure loss to minimize the installed heating and cooling capacity, reduce fan motor size while maximizing overall system performance and client energy savings. In our view, the total energy recovery effectiveness must be optimized along with the parasitic pressure loss across the energy recovery wheel media (high RER as defined by AHRI). Recovery wheels with low latent performance require increased cooling capacities, deeper coils and frost more easily during cold weather. Recovery wheels designed to operate with high air pressure losses significantly impact fan brake horsepower requirements which erode much of the energy savings promised by the recovery device and result in lower EER ratings. REASON 2: We enable energy recovery systems to maintain a better and more consistent indoor air quality for building occupants All SEMCO wheels employ desiccant coatings that substantially reduce the amount of desiccant contaminant transfer when compared with other products, such as traditional silica gel wheels. Purge sections required to further limit contaminant transfer are a standard option for all SEMCO wheels. SEMCO recovery wheels employ fluted aluminum media for true laminar flow and require minimal maintenance. They effectively operate with low efficiency filters without impacting the long term performance of the recovery device. Recovery wheels that plug or require MERV 8 filters to protect against plugging negatively impact IAQ as increased internal static pressures diminish system airflows, especially with systems incorporating forward curve fans. Frequent and substantial reduction in the outdoor airflow is not in compliance with design codes and standards. REASON 3: Allows compliance with ASHRAE 90.1 2013 Fan Limitations and Economizer requirements ASHRAE 90.1 2013 places strict limitations on the amount of fan horsepower that can be allocated to an energy recovery system. It also requires the economizer airflow capability to equal 100% of the supply design airflow. The low pressure losses offered by the SEMCO wheels greatly simplifies the challenge of satisfying the fan horsepower limitations and allows substantially more outdoor airflow to be delivered through a given size wheel during economizer mode. REASON 4: Increase the airflow capability and/or the external static pressure capability from an existing ERV Simply upgrading the wheel in an existing ERV with the SEMCO UWC drop-in replacement will immediately provide increased external static pressure capability and/or increased system airflow capacity. In many cases, smaller fan motor sizes can be installed while maintaining the current product airflow capabilities and the cost of electrical service can be reduced. This lowers the manufacturing cost and increasing product performance. REASON 5: Variable speed wheel and controls for optimum performance and avoiding costly electric preheat Backed by 4 decades of experience designing and optimizing recovery wheel controls systems, SEMCO 4

OEM WHEEL EQUIPMENT Cooling Energy Savings Heating/Humidifcation Savings Parasitic Fan Energy (less coil loss credit) Net Annual Energy Savings $6,000 offers variable speed wheel options (controls and components) tailored to the needs of the application. Every SEMCO wheel is shipped with an inverter duty gear motor and is proven to deliver superior life in this high torque, low rotational speed application. DDC wheel controls with communications capability, differential enthalpy change-over, temperature control and frost prevention are made available for all wheel products. REASON 6: Safety First Minimizing flame and smoke generation by the recovery wheel media and full compliance with NFPA 90A The SEMCO wheel media has been tested in accordance with ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials or ANSI/ UL 723 and shown to have a flame spread and a smoke generation of 0 and 0, well below the allowable limits of 25 and 50 respectively for all duct-mounted devices complying with NFPA 90A. SEMCO wheel products have also been tested for smoke generation and combustibility in accordance with UL-900, reaching full compliance with results that were well below the criteria allowed. REASON 7: Increased reliability and reduced maintenance All SEMCO wheels employ pillow block (Fusion) or radial deep groove double sealed bearings (UWC), sized for extended operating life. Industrial duty gear motors are employed along with continuous V belt (Fusion) or adjustable link belting (UWC) to ensure a trouble free drive system. The self-cleaning fluted media resists plugging so wheel cleaning is a rarity and the life of the wheel is not reliant upon rigorous filter maintenance. $5,000 $4,000 $3,000 $2,000 $1,000 $0 Wheel Type SEMCO UWC Supply Airflow (cfm) 25 ton RTU Recovery Wheel Pressure Loss Competitive Option* FIGURE 1. Compares UWC wheel with competition with same sensible and latent efficiency but different pressure loss values (.5 vs. 1.1 ). Atlanta weather data, continuous operation, $6.00 gas, $.10 electricity Competitor SEMCO UWC 10,000 10,000.95.43 Supply Fan Horsepower (A) 12.5 hp 10.0 hp Exhaust Fan Horsepower (B) 1.5 bhp 2.5 bhp Total Fan Installed 14.0 hp 12.5 bhp Horsepower (A+B) Horsepower Alliance 12.5 bhp 12.5 bhp ASHRAE 90.1 2013 Compliance Compliant? No Yes FIGURE 2. Example of how the UWC wheel, having the same recovery effectiveness but substantially lower pressure loss can significantly reduce the installed motor horsepower and help reach compliance with ASHRAE 90.1 2013 5

FUSION SERIES PRODUCT DESCRIPTIONS The Fusion Series, with airflow capacities ranging from 1,000 CFM to 70,000 CFM, pre-cools and dehumidifies the outdoor air during the cooling season and preheats and humidifies the outdoor air during the heating season. As a result, the outdoor air quantity can be increased from 5 to 20 cfm per person without increasing energy costs. As importantly, the first cost savings associated with the reduction in chiller and heating/humidification capacity typically pay for the added cost associated with the installation of the total energy recovery equipment. The SEMCO Fusion wheel has been developed to optimize total recovery performance and wheel pressure loss, while minimizing manufacturing cost. The Fusion has been designed for projects where the degree of contaminant transfer is not a major concern and where competitive pricing is considered most important. The Fusion wheel incorporates a proprietary zeolite composite coating and provides a contaminant carryover performance that is superior to that offered by nonmolecular sieve based wheels such as those employing silica gel. Fusion wheels deliver the highest total energy recovery performance and recovery efficiency ratios (RER) of any certified 200 mm deep recovery wheels available. SEMCO Fusion wheels have been specifically developed for OEM manufacturers, and cover applications ranging from 500 cfm to 70,000 cfm in a single wheel cassette. STANDARD PRODUCT FEATURES: Industry s highest recovery performance (AHRI Certified) and Recovery Efficiency Ratios (RER) 200 mm deep transfer media Reduced contaminant carry-over compared to silica gel based energy wheels Structural steel tubing support casing to limit deflection (Size 9 and greater) Extruded aluminum structural hub, spokes and rim system Comprehensive variable speed wheel DDC controls and sensors 6

OEM WHEEL EQUIPMENT 3A The SEMCO Fusion 3A wheel has been developed to optimize total recovery performance and wheel pressure loss, while limiting desiccant contaminant carryover in a manner consistent with other 3A molecular sieve wheels. The Fusion 3A has been designed for projects where limiting contaminant transfer is desired but achieving competitive bidding is considered more important. The Fusion 3A incorporates the same high-grade 3A molecular sieve and binding system used to produce the SEMCO True 3Å wheel. However, the Fusion 3A is produced without the use of SEMCO s propriety 27 step process necessary to stabilize the cations and achieve true 3 angstrom behavior. While the Fusion 3A does not limit contaminant carry-over to the degree possible with the SEMCO True 3Å wheel, the cost of manufacturing the product is significantly reduced, allowing us to offer our OEM customers a more competitive, second tier 3A product. APPLICATION LIMITATIONS: Recommended for non-critical applications where limiting contaminant transfer is desired. Non-critical applications can be defined by ASHRAE 62 Class 1 or Class 2 spaces where contamination transfer levels should be limited below 10%. This would include applications where the exhaust air stream contained chemicals with mild odors such as toilet exhaust. The Fusion 3A is available to OEM customers on a job by job basis where SEMCO can evaluate the specific needs of critical applications and ensure a successful project for the OEM, the end user, and SEMCO. SEMCO Fusion 3A Fusion 3A delivers the highest total energy recovery performance and recovery efficiency ratios (RER) of any certified 200 mm recovery wheel available. STANDARD PRODUCT FEATURES: Industry s highest recovery performance (AHRI Certified) and Recovery Efficiency Ratios (RER) 200 mm deep transfer media Reduced contaminant carry-over equal to or better than other competitors wheels marketed as using a 3A molecular sieve (See Figure 3) Anti-corrosion face coating standard Measured Average Contaminant Carry-over Percentage (%) FIGURE 3: Results based upon laboratory testing showing average contaminant carry-over for eight different chemical families. ASHRAE 84 procedures followed, contaminant families chosen by the Georgia Tech Research Institute (GTRI) 7

FUSION SERIES PERFORMANCE DATA & DIMENSIONS PERFORMANCE DATA FOR FUSION AND FUSION 3A WHEELS Velocity fpm Effectiveness % Press. Drop in.wg Air Flow Rate (in cfm) Wheel Size 3 5 9 13 18 24 28 35 43 46 56 70 300 83.80 0.24 840 1,590 2,580 3,930 5,430 7,140 8,490 10,560 12,870 13,920 16,800 21,120 400 81.22 0.33 1,120 2,120 3,440 5,240 7,240 9,520 11,320 14,080 17,160 18,560 22,400 28,160 500 78.64 0.42 1,400 2,650 4,300 6,550 9,050 11,900 14,150 17,600 21,450 23,200 28,000 35,200 600 76.05 0.52 1,680 3,180 5,160 7,860 10,860 14,280 16,980 21,120 25,740 27,840 33,600 42,240 700 73.47 0.62 1,960 3,710 6,020 9,170 12,670 16,660 19,810 24,640 30,030 32,480 39,200 49,280 800 70.89 0.73 2,240 4,420 6,880 10,480 14,480 19,040 22,640 28,160 34,320 37,120 44,800 56,320 900 68.31 0.84 2,520 4,770 7,740 11,790 16,290 21,420 25,470 31,680 38,610 41,760 50,400 63,360 1000 65.73 0.96 2,800 5,300 8,600 13,100 18,100 23,800 28,300 35,200 42,900 46,400 56,000 70,400 1100 63.15 1.09 3,080 5,830 9,460 14,410 19,910 26,180 31,130 38,720 47,190 51,040 61,600 77,440 FUSION AND FUSION 3A WHEEL UNIT DIMENSIONS SIZES 13-70 SIZES 3, 5 AND 9 Mounting Arrangements A, B Mounting Arrangements C, D, E, and F Y A D A E V E B C B D C X Wheel Size Dimensions (inches) A B C D E Net Wt. (lbs.) Flow area / side, ft 2 Nominal cfm Z V Z W 3 39.8 48.8 17.25 19.2 18.4 330 2.8 2,000 5 51.8 58.2 17.25 25.2 24.4 450 5.3 4,000 9 63.8 70.2 17.25 31.2 30.4 600 8.6 7,000 Wheel Size Dimensions (inches) V W X Y Z Net Wt. (lbs.) Flow area/side, ft2 Nominal cfm 13 75.8 18.25 33.8 40.0 36.9 940 13.1 10,500 18 87.8 18.25 39.8 46.0 42.9 1140 18.1 15,500 24 99.8 18.25 45.8 52.0 48.9 1420 23.8 19,000 28 111.8 20.25 49.8 59.0 54.4 2370 28.3 22,500 35 123.8 20.25 55.8 65.0 60.4 2685 35.2 28,000 43 135.8 20.25 61.8 71.0 66.4 3025 42.9 34,000 46 141.0 20.25 64.4 73.6 69.0 3180 46.2 37,000 56 154.0 20.25 70.9 80.1 75.5 3580 56.0 45,000 70 171.5 20.25 79.6 88.9 84.3 4140 70.4 56,000 8

CONTROLS INFORMATION & FEATURES OEM WHEEL EQUIPMENT Wheel Control Package SEMCO provides a controller, rotation detector board, keypad, and terminal strip mounted in a Nema 1 enclosure. Four point style temperature sensors, the wheel variable frequency drive, and rotation detector pickup ship loose. Factory controls packages include the following components by SEMCO: Wheel gearmotor and VFD I/O Zone 583 Controller BACview5 2 row x 20 column keypad (4) point temperature sensors to be mounted in the outdoor, supply, extract, and exhaust airstreams Rotation detector Control Functionality Supply temperature based variable wheel speed control Wheel condensation control Rotation alarm BACnet MS/TP, ARC156, Modbus or N2 communications Wheel Control Package Upgrades When chosen, this package includes all of the functionality of the Wheel Control Package with the addition of humidity based discharge control and an upgraded wheel control strategy. Includes ALL of the Wheel Control Package with additions or upgrades as follows: I/O Zone 583 Controller upgrade to I/O Flex 6126 Keypad upgrade to BACview6 4 row x 40 column (2) point temperature sensors to be mounted in the supply and exhaust airstreams (2) combination temperature/rh sensors to be mounted in the outdoor and extract airstreams Enthalpy based summer/winter changeover Automatic condensation control setpoint 9

UNITARY WHEEL CASSETTE PRODUCT DESCRIPTIONS The Unitary Wheel Cassette (UWC) recovers both sensible and latent energy, and does so far more effectively than other competitive offerings. You now can have the quality and performance of a SEMCO energy recovery wheel in your existing OEM wheel application. The performance edge is a result of UWC s unique transfer core. The fluted opening design utilizes a sturdy, but lightweight, all-aluminum wheel substrate coated with a fast-acting, corrosion-resistant, proprietary desiccant. The honeycomb matrix s fluted opening design efficiently produces maximum latent and sensible air-toair heat transfer, but generates up to 50-percent less HVAC system static pressure than polymer film wheels. UWC 3A delivers the highest total energy recovery performance and recovery efficiency ratio (RER) of any certified 100 mm recovery wheel available. The UWC series provides the perfect solution to upgrade or replace the plastic disposable wheel in your ERU. These wheels can be found in Aaon, Greenheck, Carrier, ClimateMaster, Lennox, McQuay, and other manufacturers energy recovery units. The UWC provides the perfect solution to the ASHRAE Standard 62, Ventilation for Acceptable Indoor Air Quality. Airflow capacities range from 700 CFM to 15,000 CFM. For applications where limiting contaminant transfer is desired, the UWC 3A can be incorporated. These wheels incorporate a high-grade 3A molecular sieve and binding system used to produce the SEMCO True 3Å wheel but do not achieve true 3 angstrom behavior. UWC 3A is not recommended for critical applications, but specific critical applications can be evaluated by SEMCO before reaching a final conclusion regarding a specific project. 10

OEM WHEEL EQUIPMENT THE UWC PROVIDES THE PERFECT SOLUTION TO UPGRADE OR REPLACE THE PLASTIC DISPOSABLE WHEEL IN YOUR ERU. AHRI Certified Independently tested in accordance with ASHRAE 84 and verified to assure the equipment will perform accurately and consistently. Superior Performance UWC performance is superior to all other air-to-air energy recovery wheels. Compact Design Fast absorption of moisture, giving a high latent efficiency even at high air flow rates. Efficient Very high effectiveness, up to 77%. High sensible and latent efficiencies, with industry-leading transfer of moisture. Meets Smoke & Flame Spread Ratings Wheel independently certified to pass NFPA 90A requirements for flame spread and smoke generation based upon ASTM E84 fire test method. Corrosion Resistance The ceramic coating on the rotor gives extremely high corrosion protection. Unique flute design A unique flute design, coupled with numerous other design innovations, provides for the highest possible heat transfer characteristics while simultaneously reducing pressure loss parameters. Non-oxidized coated media The media is made from aluminum which is evenly coated with a dense layer of corrosion resistant desiccant. This extends the life of the aluminum media substrate and enhances its structural integrity. Low Leakage Seals The UWC is supplied with hybrid brush/barrier perimeter and face contact seals to minimize air leakage and wheel bypass. Light Weight Media Support The media support members (hub, spokes and rims) are aluminum extrusions. This combines strength with precision to form the ideal sealing surface. Ease of Installation The UWC is designed to be direct replacement for the stacked plate, dimpled plastic wheels in most applications and can be easily installed in just a few minutes. Lifetime Performance The UWC is designed and built to provide long and reliable operation for the life of the equipment it s installed in. Use of the AHRI Certified mark indicates a manufacturer s participation in the certification program. For verification of certification for individual products, go to www.ahrinet.org. 11

UNITARY WHEEL CASSETTE PERFORMANCE DATA & DIMENSIONS UWC WHEEL CASSETTE DATA UWCH WHEEL CASSETTE DATA Velocity (SFPM) Effectiveness Sensible Latent Total Pressure Loss (inwg) Velocity (SFPM) Effectiveness Sensible Latent Total Pressure Loss (inwg) 200 75 76 75 0.16 300 73 73 73 0.20 400 72 70 71 0.25 500 70 67 69 0.31 600 68 64 67 0.39 700 66 61 65 0.47 800 64 58 62 0.56 900 62 55 60 0.65 1000 59 52 57 0.74 UWC wheel media employs a larger flute size, resulting in lower pressure loss and performance at the lowest product cost. 200 79 80 79 0.24 300 78 77 78 0.29 400 77 75 76 0.36 500 75 72 74 0.46 600 73 69 72 0.57 700 71 66 70 0.69 800 69 63 67 0.82 900 67 60 65 0.94 1000 65 57 63 1.05 UWCH wheel media employs a smaller flute size, resulting in higher recovery performance at a slightly higher pressure loss and product cost. Velocity (SFPM) UWC OR UWCH MODEL NUMBER 30 36 41 46 52 58 64 68 74 AIRFLOW (SCFM) 200 400 600 820 1,040 1,420 1,840 2,140 2,500 2,960 300 600 900 1,230 1,560 2,130 2,760 3,210 3,750 4,440 400 800 1,200 1,640 2,080 2,840 3,680 4,280 5,000 5,920 500 1,000 1,500 2,050 2,600 3,550 4,600 5,350 6,250 7,400 600 1,200 1,800 2,460 3,120 4,260 5,520 6,420 7,500 8,880 700 1,400 2,100 2,870 3,640 4,970 6,440 7,490 8,750 10,360 800 1,600 2,400 3,280 4,160 5,680 7,360 8,560 10,000 11,840 900 1,800 2,700 3,690 4,680 6,390 8,280 9,630 11,250 13,320 1000 2,000 3,000 4,100 5,200 7,100 9,200 10,700 12,500 14,800 12

UWC & UWCH WHEEL DIMENSIONS A F D C UWC/UWCH wheels are provided with a prewired motor wiring harness including an integrated connector. B E ØG C L H Wheel Dimensions (inches) A B C D E F G H (Notes 1 & 2) UWC Net Weight (lbs) UWCH Net Weight (lbs) 30 34.0 34.0 2.04 15.98 1.31 4.36 30 5.5 105 111 36 39.80 39.80 2.82 18.40 1.31 4.36 36 5.5* 130 138 41 44.00 44.00 3.10 20.50 1.58 4.36 41 5.5* 158 168 46 50.00 50.00 3.10 23.50 1.58 4.36 46 5.5* 177 189 52 56.19 56.19 3.10 26.50 1.58 4.36 52 5.5* 201 216 58 62.42 62.42 3.10 29.70 2.05 4.36 58 7.5* 238 257 64 68.00 68.00 5.00 31.50 2.05 6.07 64 7.5* 247 270 68 72.00 72.00 6.00 33.00 2.05 7.07 68 7.5* 262 288 74 78.00 78.00 6.00 36.00 2.05 7.07 74 7.5* 285 316 * Add 2" to H Dimension for the following applications: Constant Speed - 220V/1PH or 575V/3PH Variable Speed - 460V/3PH or 575V/3PH

Sales/Design Tools Offered to OEM Partners: DLL performance software for integration into the selection software of OEM customers. Stand-alone software for product selection, analysis and sales support which provides: Selection guidance based on airflow Performance data for cooling and heating conditions at any selected conditions Easy energy analysis calculations for various U.S. cities complete with graphical output suitable for providing to the clients or engineers of OEM customers RER calculations Performance schedules for the UWC/UWCH total energy recovery wheels Frost alarm warnings and recommendations is variable wheel frost control is employed Full UWC/UWCH submittal output if desired Numerous certifications and independent test reports on product performance 40 years of application knowledge and expertise UWC / UWCH Product Features: Industry s highest recovery performance (AHRI Certified) and Recovery Efficiency Ratios (RER) 100 mm deep transfer media Reduced contaminant carryover compared to silica gel based energy wheels Structural sheet metal with tubular bearing support Structural aluminum media spoke system with extruded aluminum inner hub Comprehensive variable speed wheel DDC controls and sensors (optional) 14

OEM WHEEL EQUIPMENT PROVIDING SOLUTIONS TO ASHRAE STANDARDS Indoor Air Quality The ASHRAE 62.1-2013 standard identifies the quantity of ventilation required to be delivered to a space to support acceptable indoor air quality within a commercial building. Section 5.9.1 identifies that the acceptable limit to indoor relative humidity in an occupied space be no greater than 65%. However, as identified in field studies (Bayer C. W., S. Crow and J. Fischer. 2000. Causes of Indoor Air Quality Problems in Schools. U.S. Department of Energy Report, Oak Ridge National Laboratory, ORNL/M-6633/ R1.) and plotted against the ASHRAE 55 comfort standard (Fischer J., Bayer C.W., 2003, Report Card on Humidity Control, ASHRAE Journal May, 2003) higher relative humidity does not promote energy savings as thermal comfort in a humid space requires a lower space temperature to satisfy occupants. Ideally the space relative humidity would be kept in a range of 40-60%, with emphasis on the lower half of the range. Section 5.16.2 discusses the re-designation of air classifications. This specifically outlines what types of space air is allowed for recirculation versus direct exhaust to the outdoors. Class 1, Class 2, and Class 3 air (that covers most of the small commercial building market air classifications) allows air to air energy recovery use with defined limits on Class 2 and 3. The limit as per section 5.16.3.2.5 is that recirculated Class 2 air shall not exceed 10% of the outdoor intake flow. Class 3 air is limited to 5% of the outdoor intake flow per section 5.16.3.3.2. This means that energy recovery is approved for use in small commercial buildings as long as their design meets the acceptable limits. Recirculated air does not replace the outdoor air required to comply with ASHRAE 62. If 10% of the exhaust is recirculated, the airflow to the coil must be increased by that amount which results in higher cooling, heating and fan energy use. Limiting recirculation of air and contaminants through the use of a proper purge and desiccant coating avoids the need of moving higher airflows through the dedicated outdoor air system and ductwork. Energy Efficiency ASHRAE Standard 90.1-2013 defines the minimum energy efficiency requirements for the design team with regards to commercial buildings (excluding low rise residential buildings). Section 6.5.6 explains that the use of exhaust air energy recovery must have at least 50% enthalpy recovery effectiveness. This means that the outdoor air supply must be >50% of the difference between the entering outside air and the exhausted (recoverable) air enthalpies. The application of the wheel is further defined by climate zone and outdoor airflow percentage of the total system (outdoor air supply air). Table 6.5.6.1 breaks down the climate regions and tabulates the airflow volumes, making the exhaust air recovery requirements easily identifiable. Nearly 80% of the United States has adopted a version of ASHRAE 90.1 as a state code regulation. Some states have mandated public sector applications to exceed the requirements of 90.1 by 30% or more, giving further justification for energy savings measures to have priority. 15

SEMCO OEM Wheel Equipment Technical Sales BR www.semcohvac.com WE BRING AIR TO LIFE WWW.SEMCOHVAC.COM OEM Wheel Equipment 20160304 SEMCO is a global leader in air management. We specialize in the design and manufacture of a wide range of air climate and air movement solutions. Our collective experience is unrivaled. Our constant aim is to provide systems that precisely deliver the best indoor air quality and performance, as well as maximize energy efficiency. SEMCO A Fläkt Woods Company Corporate Headquarters 1800 East Pointe Drive Columbia, Missouri 65201 USA 573 443 1481 sales.semco@flaktwoods.com To learn more about SEMCO offerings and to contact your nearest representative please visit www.semcohvac.com SEMCO embraces a policy of continuous development and improvement, the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied upon request on receipt of order. SEMCO LLC 2016 All Rights Reserved. SEMCO and the SEMCO logo are registered Trademarks of SEMCO LLC.