Electrical Conductors

Similar documents
Engineering Data for Copper and Aluminum Conductor Electrical Cables

SERV-RITE Wire and Cable

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

Glossary Of Terms M-1

FEDERAL STANDARD TEST METHODS FOR CABLES AND WIRE, INSULATED

FEDERAL STANDARD TEST METHODS FOR CABLES AND WIRE, INSULATED

DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER, COLUMBUS POST OFFICE BOX 3990 COLUMBUS, OH

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

Industry Application Information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

Introduction to Cathodic Protection

PRODUCT SELECTION GUIDE

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

PI Electrical Equipment - tourse PI 30.2 INSULATION. On completion of this module the student will be able to:

MILITARY SPECIFICATION WIRE, ELECTRICAL, FLUOROPOLYMER - INSULATED COPPER OR COPPER ALLOY

Technical Data. Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE

Heritage Quality Performance

3 MODIFICATIONS TO EXISTING STANDARDS

Will accommodate up to 35 conductors while maintaining separation required to withstand instrumentation voltages

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-21

SECTION GROUNDING AND BONDING

15 kv EPR Insulated, Jacketed, URD Cable

Electrical Machine Design. Chapter.1 PRINCIPLES OF ELECTRICAL MACHINE DESIGN

Your Partner for Custom Interconnectivity Solutions. ISO 9001 AS9100C ISO ISO Qualified

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL

FABRICATED STEEL PIPE AND SPECIALS

*** Supercedes: BECO E and COM , , & ***

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

Article 300: Wiring Methods And Materials

Power Systems 2 ELE3015. Lecture 1: Transmission Lines

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

Standard of Practice - Campus Electrical Distribution System

SMA SERIES COAXIAL CONNECTORS

PERFORMANCE SPECIFICATION SHEET

QUALIFICATION UPDATE. Eric Rasmussen. Quality Cables Since 1854

M16 M20 M25 M207 M51 M100 M200

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CHAPTER LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2011 EDITION

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

WIRING METHODS CHAPTER 38

Science and Health CLASSIFYING MATERIALS INTO CONDUCTORS AND INSULATORS

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

TECHNICAL DATA. A REFERENCE FOR The Electrical Power Industry. www. ElectricalPartManuals. com ANDERSON POWER SYSTEMS, INC.

Proven Capabilities. Features and Benefits. Watlow provides:

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

Amphenol RF- SMA Connector Series

MSME Testing Centre, 65/1, G. S. T. Road, Guindy, Chennai, Tamil Nadu. Discipline Electrical Testing Issue Date

Percon 28 Copper Alloy Conductor Wire

6A-38 Jumper Wire (IJP) (Rank A)

Sections through of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE

A LIGHTWEIGHT SOLUTION FOR SHIELDING AND CONDUCTING

A Marmon Engineered Wire & Cable Company

International Thermocouple and Extension Grade Wire Color Codes

Mining Products. Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items

Mining Products Jacketing and Insulating Tapes Trailing Cable Splice Kits High Voltage Splice and Termination Kits Cable Repair Tape Special Items Fon

SERV-RITE Wire. Product Description Page. Thermocouple and Extension Wire

BLACK EPR INSULATED MEDIUM VOLTAGE CABLES. Ronald F. Frank, Eng. Consultant

PVC Insulating Tape. Electrical Tapes

DETAIL SPECIFICATION WIRE, ELECTRICAL, INSULATED, GENERAL SPECIFICATION FOR

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +90 C, TYPE LS3SWU (INCLUDING VARIATION LS3SWUS)

Amphenol Amphenol Taiwan Corporation Sheet 1 of 8

SPECIFICATION FOR FRLS POWER CABLES

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

Thermocouples and Accessories Product Catalog

Wire and Cable SPEC 44 Wire and Cable

All types of NOMEX are sold in 610mm and 914mm roles (type 411) and in 4mm onwards wide strips.

Insulators and Conductors

ADAPTORS. SMA / SMB / N to SSMB / TNC. Part No. 1A Part No. 1A N PLUG TO TNC PLUG. Part No. 1A Part No.

SECTION GROUNDING AND BONDING

PERFORMANCE SPECIFICATION SHEET

EIU 105 Types of Non-Electrical Insulation Materials

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5

26/35kV Copper XLPE Insulation Electric Cable

Basic Electrical Theory by: Brian H. Hurd. Work

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building

Gage Series Stress Analysis Gages

SECTION HEAT TRACING FOR PLUMBING PIPING

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

New Conduit Specification

solutions HIGH DENSITY CONNECTORS Custom designed Contact arrangements

DETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE, SPECIAL PURPOSE, ELECTRICAL, MULTICONDUCTOR AND SINGLE SHIELDED, GENERAL SPECIFICATION FOR

Una e mpre sa Vi akab l e GLOSSARY.

DETAIL SPECIFICATION CABLE, POWER, ELECTRICAL AND CABLE SPECIAL PURPOSE, ELECTRICAL SHIELDED AND UNSHIELDED, GENERAL SPECIFICATION FOR

SECTION WIRES AND CABLES

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

Galvanic and Stray Current Corrosion

SECTION 2: PROBES. Page 2-1

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

International Thermocouple and Extension Grade Wire Color Codes

POLYMERIC ARMOR DESIGN OF AN IMPROVED PROTECTION TO MECHANICAL STRESSES AND FLUIDS FOR OIL GAS AND PETROCHEM (OGP) APPLICATIONS

Transcription:

Electrical Conductors Course No: E02-005 Credit: 2 PDH A. Bhatia Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 info@cedengineering.com

CHAPTER 1 ELECTRICAL CONDUCTORS LEARNING OBJECTIVES ELECTRICAL CONDUCTORS CONDUCTOR SIZES

SQUARE MIL Figure 1-1. Cross-sectional areas of conductors. Q1. State the reason for the establishment of a "unit size" for conductors. Q2. Calculate the diameter in MILS of a conductor that has a diameter of 0.375 inch. Q3. Define a mil-foot. Q4. Define a square mil as it relates to a square conductor. CIRCULAR MIL π π

Figure 1-2. A comparison of circular and square mils. π

Q5. Define a circular mil. Q6. What is the circular mil area of a 19-strand conductor if each strand is 0.004 inch? CIRCULAR-MIL-FOOT Figure 1-3. Circular-mil-foot.

SPECIFIC RESISTANCE OR RESISTIVITY Table 1-1. Specific Resistances of Common Substances

Q7. Define specific resistance. Q8. List the three factors used to calculate resistance of a particular conductor in ohms. WIRE SIZES

Table 1-2. Standard Solid Copper (American Wire Gauge)

Figure 1-4. Wire gauge. Q9. Using table 1-2, determine the resistance of 1,500 feet of AWG 20 wire at 25º C. Q10. When using an American Standard Wire Gauge to determine the size of a wire, where should you place the wire in the gauge to get the correct measurement? STRANDED WIRES AND CABLES

Figure 1-5. Conductors. Figure 1-6. Stranded conductor.

SELECTION OF WIRE SIZE FACTORS GOVERNING THE CURRENT RATING CONDUCTOR SIZE WIRE LOCATION INSULATION

SAFE CURRENT RATINGS Table 1-3. Temperature Ratings and Current-Carrying Capacities (in Amperes) of Some Single Copper Conductors at Ambient Temperatures of 30ºC Q11. List the four factors you should use to select wire for a specified current rating. Q12. What are three types of nonmetallic insulating materials that can be used in a high-temperature environments? Q13. State why it is important for you to consider the ambient (surrounding) temperature of a conductor when selecting wire size. COPPER-VERSUS-ALUMINUM CONDUCTORS

Table 1-4. Comparative Characteristics of Copper and Aluminum Q14. State two advantages of using aluminum wire for carrying electricity over long distances. Q15. State four advantages of copper over aluminum as a conductor. TEMPERATURE COEFFICIENT Q16. Define the temperature coefficient of resistance. Q17. What happens to the resistance of copper when it is heated? CONDUCTOR INSULATION

INSULATION RESISTANCE DIELECTRIC STRENGTH Q18. Compare the resistance of a conductor to that of an insulator. Q19. State two fundamental properties of insulating materials. Q20. Define insulation resistance. Q21. Define dielectric strength. Q22. How is the dielectric strength of an insulator determined? TYPES OF INSULATION Rubber

Figure 1-7. Rubber insulation. CODE-GRADED RUBBER LATEX RUBBER SILICONE Q23. What is the purpose of coating a copper conductor with tin when rubber insulation is used?

Plastics Varnished Cambric Figure 1-8. Varnished cambric insulation.

Extruded Polytetrafluoroethylene WARNING Avoid breathing the vapors from extruded polytetrafluoroethylene insulation when it is heated. Symptoms of overexposure are dizziness or headaches. These symptoms disappear upon exposure to fresh air. Q24. What safety precaution should you take when working with extruded polytetrafluoroethylene insulated wiring? Fluorinated Ethylene Propylene (FEP) Asbestos WARNING Avoid inhalation of asbestos fibers. Asbestos fibers have been found to cause severe lung damage (asbestosis) and cancer of the gastrointestinal tract. Follow Navy safety precautions when working with all asbestos products. Figure 1-9. Asbestos Insulation.

Figure 1-10. Asbestos and varnished cambric insulation. Q25. State the reasons that the Navy is getting away from the use of asbestos insulation. Q26. State what happens to the insulating characteristics of asbestos when it gets wet. Paper

Figure 1-11. Paper-insulated power cables. Q27. What are the most common insulators used for extremely high voltages? Silk and Cotton Figure 1-12. Silk and cotton Insulation. Enamel

Figure 1-13. Enamel Insulation. Q28. What is the common name for enamel-insulated wire? Mineral Insulated Figure 1-14. Two-conductor mineral-insulated (MI) cable. CONDUCTOR PROTECTION

Q29. If a cable is installed where it receives rough treatment, what should be added? NONMETALLIC PROTECTION Fibrous Braid Figure 1-15. Fibrous braid covering. Fibrous Tape

Q30. How many categories of nonmetallic protective coverings are there? Q31. What is the most common type of nonmetallic material used to protect wires and cables? Q32. What are the most common types of fibrous tape? Woven Covers Rubber and Synthetic Coverings Jute and Asphalt Coverings Unspun Felted Cotton Q33. What materials are commonly used as cushions between cable insulation and metallic armor? METALLIC PROTECTION Metallic Sheath

Figure 1-16. Lead-sheathed cable. Metallic Armor Figure 1-17. Metallic armor cable. WIRE-BRAID ARMOR

STEEL TAPE WIRE ARMOR Q34. What are the two types of metallic protection? Q35. What are the three types of lead-sheathed cables? Q36. What are the three examples of metallic armor cable that were discussed? COAXIAL CABLE Figure 1-18. Coaxial cable. SUMMARY Unit Size

Conductor Sizes π Specific Resistance Wire Gauge Selection of Wire Size

Copper-versus-Aluminum Conductors Temperature Coefficient of Resistance Conductor Insulation Insulating Materials Conductor Protection

ANSWERS TO QUESTIONS Q1. THROUGH Q36. A1. To allow comparisons between conductors of different sizes and resistance. A2. 375 mils (move the decimal three places to the right). A3. A circular conductor with a diameter of 1 mil and a length of 1 foot. A4. The cross-sectional area of a square conductor with a side of 1 mil. A5. The cross-sectional area of a circular conductor with a diameter of 1 mil. A6. Circular mil area (CMA) = D 2 (in mils) number of strands0.0004 inch = 4 mils (CMA) = 4 2 19 (strands)(cma) = 16 19 = 304 mils. A7. The resistance of a unit volume of a substance. A8. Length, cross-sectional area, and specific resistance of a unit volume of the substance from which the conductor is made. A9. 1,000 ft = 10.4 ohms1,500 ft = 1.5 0.4 = 15.6 ohms A10. In the parallel walled slot not the circular area. A11. Conductor size, the material it is made of the location of the wire in a circuit, and the type of insulation used. A12. FEP, extruded polytetrafluoroethylene, and silicone rubber. A13. The heat surrounding the conductor is an important part of total conductor heating. A14. It is light and reduces corona. A15. It has higher conductivity, it is more ductile, it has relatively high tensile strength, and it can be easily soldered. A16. The amount of increase in the resistance of a 1-ohm sample of the conductor per degree of temperature rise above 0º C A17. It increases. A18. Conductors have a very low resistance and insulators have a resistance that is so great that, for all practical purposes, they are nonconductors. A19. Insulation resistance and dielectric strength. A20. The resistance to current leakage through the insulation. A21. The ability of the insulation material to withstand potential difference. A22. By raising the voltage on a test sample until it breaks down. A23. To prevent the rubber insulation from deteriorating due to chemical action. A24. Avoid breathing the vapors when the insulation is heated. A25. Breathing asbestos fibers can cause lung disease and/or cancer A26. It will become a conductor. A27. Varnished cambric and oil-impregnated paper. A28. Magnet wire.

A29. Metallic coat. A30. Three. A31. Fibrous Braid. A32. Rubber-filled cloth tape and a combination of cotton cloth and rubber. A33. Jute and Asphalt coverings. A34. Sheath and armor A35. Alloy lead, pure lead, and reinforced lead. A36. Wire braid, steel tape, and wire armor