GAS 3050P NDIR FLUE GAS

Similar documents
( ppm ) ( ppm ) ( ppm ) History :46:43

Portable Infrared Flue Gas Analyzer Gasboard 3800P

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

PORTABLE FLUE GAS ANALYZER

Online Infrared Flue Gas Analyzer Gasboard 3000

madur GA21p-EN-v portable gas analyser

EQUIPMENT APPEARANCE. madur. portable gas analyser

Online Gas Analyzer / Monitor

SEMI-CONTINUOUS EMISSION MONITORING SYSTEM

madur portable gas analyser

madur portable gas analyser

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Compact body packed with abundant functions Fuji infrared gas analyzer

Portable combustion and emissions analysers

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

Compact flue gas analyser: testo 300 M-I

COLow COHigh COLow/H 2

COLow COHigh COLow/H 2 NO 2 CO 2 H 2 S SO 2 C X H Y LANCOM 4. Portable Flue Gas Monitoring. comp NO NOx

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

COLow COHigh COLow/H 2

Chemist Industrial emissions analyser

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

Automatic Isokinetic Sampler ST5

testo 335 New measurement engineering for monitoring emissions

UniGas Hand-held combustion gas analyzer with 4 sensors

Fpollutant-free zero air for analytical

Robust flue gas probes for industrial emissions measurements.

EuroFID Total Hydrocarbon Analyzer

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

testo 350. For emission testing and combustion analysis. Portable Emission Analyzer

Reference flue gas analyzer

Designed to meet BS7927, TUV, ISO, Gastec QA Criteria, GOST, Qualigaz, and UNI 10389

EMIOTEST 3114 Gravimetric dust meter set

New Measurement Engineering For Monitoring Emissions In Industry

Fine particle measuring system

Professional flue gas analyzer

ONLINE FLUE GAS ANALYZERS

testo 340 Speed, power & precision in industrial combustion analysis.

testo 445 Additional information at Service instrument for ventilation/air conditioning systems

Flue gas analyzer for industry

Indoor Air Quality Tools

Flue gas analyzer for industry

Professional flue gas analyzer Testo AG LPG

REFERENCE MEASURING INSTRUMENT

Online data sheet MCS100E HW-C CEMS SOLUTIONS

Highly efficient flue gas analyzer

Professional flue gas analyzer

testo 340 Speed, power & precision in industrial combustion analysis.

Analyzer Module Wet Chemiluminescence Detection (WCLD)

Highly efficient flue gas analyser with Bluetooth

GreenLine 8000 GAS ANALYSIS. Portable Industrial Combustion & Emission Analyser O 2 CO 2 CO CO% SO 2 CH X Y NO 2 HS 2

SERVOMEX PRODUCT OVERVIEW

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Highly efficient flue gas analyzer

testo 350 M testo 350 XL

Flue gas analyser MAXILYZER NG Plus

Flue gas analyzer for industry

Flue Gas Analysing System

Highly efficient flue gas analyzer

Multi-function VAC measuring instrument

INFRARED GAS ANALYZER

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

testo 350-S/-XL testo 350 S/XL, flexible flue gas measuring system Additional information at Control unit Analysis box

Rasi 900 series Emission analyser

Portable Emission Analyzer System

Fine particle measuring system

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

Analysis systems. Analysis system for CO, Nox, O2, T. Analysis systems for CO, O2, T multiplexing, OPC

VAC measuring instrument

Flue gas analyzer for industry

GAA330-M Emission monitoring system for marine applications

Comparison Continuous Emission Monitoring Techniques

EXM400. Online Gas Analyser. Specialist Of UV Spectroscopy

Using the PPM2 Portable Trace Moisture Transmitter

RASI 700 CA Combustion Analyser for O2, C0, NO(NOX) and SO2

CH88 In Situ Flue Gas Oxygen Transmitter

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

testo 340 The Ultimate Instrument in Portable Combustion Tuning NEW! testo350.com/340 4-Gas Analyzer (800)

ZP Series of Small, High-sensitivity Infrared Gas Analyzers

Flue gas analyzer for industry

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

Model Product Description and Specifications

Differential pressure measuring instrument

Just a few clicks away from a heating system diagnosis.

LIQUID METER TYPE FMO

CEM400. Online Gas Analyser. Specialist Of UV Spectroscopy

VAC measuring instrument

VAC measuring instrument

Flue gas analyzer for industry

Flue gas analyzer for industry

New Measurement Engineering For Monitoring Emissions In Industry

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

Just a few clicks away from a heating system

Heated FID OVF Portable THC/TVOC Analyzer

PMx Sequential Samplers Giano & Gemini

testo 350. For emission testing and combustion analysis. Portable Emission Analyzer

Fast-action and userfriendly. exchange by the user on site

Transcription:

Portable gas analyser GAS 3050P NDIR FLUE GAS Industrial flue gas analysis Powerful, robust and transportable on any industrial site, the GAS 3050P NDIR FLUE GAS analyser offers the same performances as a flue gas analysis system for continuous emission measurement (AMS). This analyser implements up to 4 micro-flow NDIR optical benches for CO, CO 2, NO and SO 2 and one galvanic fuel cell for O 2 (paramagnetic detector in option). NO x are obtained by calculation or are measured after NO 2 conversion into NO by an external catalytic converter (optional). Up to 13 simultaneous measures & calculations Gas measures: CO + NO (X) + SO 2 (ppm) + CO 2 % + O 2 % Physical parameters: Tgas + Tamb + Pamb + Pdiff + Vs (m/s) (by external thermocouple/s-type Pitot probe) Calculated parameters: NOx = NO*1.05 (coefficient is configurable by the user) Q (m³/h) (for quantifying the volume of emitted pollutants) Eff (combustion efficiency) α (excess of air) 5 gases : NO (X) - SO 2 - CO - CO 2 - O 2 Accuracy and linearity : conform to EN 15267-3 Reference methods (SRM) : CO (EN 15058 / EPA 10) - NDIR micro-flow O 2 (EN 14789 ) - Paramagnetic (option) SO 2 (EPA 6C) - CO 2 (EPA 3A) - NDIR micro-flow Suitable for long term flue gas measures at industrial combustions sources: Power utilities, refineries, chemical plants, cement industry, blast furnace, heat treatment furnace, waste incinerators, biogas cogeneration, etc. Suitable for compliance testing at: Engines, turbines, boilers, furnaces, etc. SO 2 0107 Infrared Flue Gas Analyzer O 2 11.30 NO 0031 CO 2 14.72 CO 0534 Measure Zero More Settings History 2012-12-26 10:46:43 SO2 NO CO O2 CO2 0107 0031 0534 11.30 14.72 T gas ( C ) Dynamic P ( Pa ) Vs ( m/s ) Gas Flow ( m³/h ) Print 0172 0013 00.00 0000000 Esc T amb ( C ) P amb ( hpa ) Eff α 019.7 100.4 00.00 00.00 Optional accessories Portable gas sampling and pre-treatment unit model GAS 3000P COOLER, with pump, Peltier gas cooler with peristaltic pump, 0.1µm particulate filter, temperature controllers for gas cooler and heated line. Portable industrial heated gas sampling probe (Tgas 600 C) model GAS 3000P PROBE, with heated pipe, removable and washable stainless steel filter and 3 or 5m heated line Combined Pitot/thermocouple probe for measurement of Tgas, Pamb, Pdiff, gas velocity and calculation of gas flow. PT100 probe for Tamb measure Portable NO 2 NO catalytic converter (heated at 410 C), for NOx measurement Calibration kit (set of non-refillable 110L precision gas cylinders & pressure regulator) Maintenance kit (spare parts and consumables)

Technical specifications of the analyser Measured gases 5-gas configuration : NO / SO 2 / CO / CO 2 / O 2 (other configurations on request) Gas analysis principle NO / SO 2 /CO /CO 2 Non-dispersive Infrared Absorption (NDIR micro-flow) NO X By calculation: NOx = NO*1.05 (setting of coefficient by user) By external catalytic conversion of NO 2 to NO (optional) O 2 Galvanic fuel cell (paramagnetic detector in option) Gas Ranges NO/SO 2 Lowest: 0-500 ppm / Standard: 0-2000 ppm / Highest: 0-9999 ppm (intermediary ranges available) CO Lowest: 0-1000 ppm / Standard: 0-5000 ppm / Highest: 0-9999 ppm CO 2 /O 2 Lowest: 0-5% / Standard: 0-25% Micro-flow NDIR detectors temperature regulation Detector enclosure with temperature regulation at +55 C to provide higher measuring stability and accuracy without effect of ambient temperature variations Measuring mode AUTO mode Factory calibration 5-points for NDIR detectors / 2-points for ECD sensor and PMG detector (option) User calibration mode 2-points (zero & span); possibility to make a low range and a high range calibration Resolution 1 ppm or mg/m³ for NO (x) /CO/SO 2-0.01% for CO 2 /O 2 Accuracy According to EN 15267-3: ± 2% FS for NO, SO 2, CO, CO 2 / ± 0.3% O 2 Repeatability ± 1% of Full Scale value Span Drift ± 1% of Full Scale/day Zero drift (off-set) Negligible, manual zeroing function for off-set re-alignment on pure ambient air Response time (T D + T 90 ) 15 s Warm up time 800 seconds (30 minutes for full performances) The temperature of NDIR gas detector can be controlled on the display of the analyser Display Touch screen LCD colour display Gas units display On 4 to 7 digits: ppm, mg/m³, %, C, Pa, hpa, m/s, m³/h Language software interface English Measured parameters Name Principle Range Resolution Precision T GAS K-Thermocouple 0 to 600 C 0.1 C ± 2 C T AMB Thermistor 0 to 100 C 0.1 C ± 1 C P AMB Pressure transducer 70 to 120kPa 0.01kPa ± 0.5kPa or ± 2%rel P DIFF Pressure transducer -50 to 50hPa 1Pa ± 2Pa or ± 5%rel V S S-type Pitot probe 3-40 m/s 0.1m/s ± 2.5% Calculated parameters α Excess of air number 0-10 0.01 E FF Combustion efficiency 0-99.99% 0.01% Q Gas volume 0-1000000 m³/h 1m³/h ± 2.5% Duct area and shape Setting of duct shape (rectangular or circle) and area (m²) by software Used for the calculation of flue gas volume : Qm³/h = m² (duct area) * V S (m/s) * 3600 Measuring cycle Programmable measuring cycle (in hours) Fuel type selection Choice of 9 pre-programmed fuel types + one user defined fuel type Sample Gas Conditions Nominal flow Nominal 1 L/min; external pump is required, integrated in the portable flue gas pre-treatment unit GAS 3000P COOLER (optional Pressure 2kPa to 50kPa Temperature Max. 50 C Quality Free of dust, water vapour and oil traces Operation conditions T AMB : 0 to 50 C / P AMB : 86 to 108kPa / R H : 5-85% non condensing Communication USB port for the 4GB Memory stick to download data recorded in the internal memory Measuring cycle Settable from 1 hour to 99 hours Logging interval Standard software: Logging interval settable from 1 minute to 99 minutes; Logging rate: 1 sec Memory data recording: automatic calculation and recording of 1 minute average data; max. recording capacity: 15.000 data; data exportation on USB memory stick. Optional software: Logging interval settable from 1 minute to 99 minutes; no calculation of average values; max. recording capacity: 15.000 data; data exportation on USB memory stick. Communication COM port for USB memory stick (4GB) for exportation of recorded data Printer Integrated thermic printer (option), AUTO print cycle programmable by software Mechanical Rough aluminium casing, with shoulder trap Dimensions: L450 x l 350 x h 180 mm / Weight: < 15 kg Power supply 240VAC - 50Hz, power cord included Standard accessories USB memory stick 4GB, ambient temperature probe, inlet/outlet tubing, technical documentation on CD-ROM

The micro-flow NDIR technology Operation principle The micro-flow NDIR detector measures gas concentration based on the principle that each type of gas component shows a unique absorption line spectrum in the infrared region. The instrument consists of an infrared light source, a chopper motor, a measurement cell and a detector filled with a gas mixture containing the reference gas. The infrared light source emits infrared light in all directions. The light emitted forward is transmitted and reflected into the detectors. The infrared light emitted backward is reflected by a reflecting surface and is added to the infrared light emitted forward. Arranged between the infrared light source and measuring cell is a chopper blade which rotates to modulate the infrared light beam at regular frequency. The modulated infrared light beam thus formed passes through the measuring cell filled with a sample gas where the light energy is partially absorbed or attenuated before it reaches the front chamber of the detector. Both the front and rear chambers of the detector are filled with the gas component to be measured. The infrared light energy is partially absorbed in the front chamber and residual light is absorbed in the rear chamber, thereby increasing pressure in both chambers. Since the detector is designed to produce a pressure difference between the front and rear chambers, a micro gas flow is produced through a path connecting these chambers with each other. This micro flow is converted into an AC electrical signal by a mass flow sensor arranged in the path connecting the chambers with each other. The AC signal is amplified and rectified to a DC voltage; after linearization it is applied to the output preamplifier of the display module. The detector shows an output signal with the greatest amplitude when zero gas is flowing in the measuring cell. Amplitude is reduced as the concentration of measured gas component increases NDIR micro-flow detectors Dual-chamber design: Allows for sharp filtering at the target wavelength Provides very good resolution between CO and CO 2 Improves temperature and pressure compensations. Highly reduces the sensitivity to moisture of NO and SO 2 measures. Enables accurate ppm range measurement of CO, NO and SO 2 Reduces off-set drift Reduces interferences: whenever the absorption spectrum of a back-ground gas overlaps the spectrum of the target gas, the pressure rises in the front and rear chambers of the detector cancel each other minimizing any response to the interference gases. Micro-flow NDIR detector is the best choice for industrial flue gas monitoring applications Chopper motors Temperature regulation (+55 C) of NDIR Micro-flow detectors for CO, CO 2, NO and SO 2

Front panel of the gas analyser and interfaces 1 220 VAC plug with POWER ON switch 2 LCD touch screen with backlight function (English software interface for configuration and calibration) 3 In-built thermic printer 4 Gas inlet port 5 Zero air inlet port 6 Gas outlet port 7 Pressure + port 8 Pressure - port 9 Flue gas temperature port 10 Earth connection 11 Ambient temperature port 12 RS232 (reserved use to manufacturer) 13 USB port for USB Memory stick 4GB (to export recorded data from internal memory to USB memory stick) Data are exported as.txt file that can be easily reworked in Excel Table or Graphics using the Microsoft Office suite. Internal view of the gas analyser Electronic Mother board Touch screen Printer (option) Power supply Temperature regulator with power relay Zero-air circuit with air pump, filter and solenoid valve Oxygen galvanic fuel cell

Industrial gas sampling probe model GAS 3000P Probe flange Heated sampling pipe at 180 C Filter Heated hose Gas sampling probe for flue gas temperature 600 C, including: Removable sampling pipe Ø8mm in stainless steel AISI316 Standard insertion length1200 mm (adjustable); other lengths up to 2500mm on request Pipe heating at 180 C with display of the real flue gas temperature on the probe handle Removable and washable end of pipe filter, 5µm, stainless steel, max. flue gas temperature 300 C (600 C in option) Adjustable flange for insertion length adaptation to duct diameter or to fix the sampling probe on an existing flange. Probe weight : ± 3 kg Delivered with 3m heated hose (5m in option), Sample gas tubing OD6/4mm in FEP* Black silk braid wear-resistant protective jacket, OD36mm Adjustable heating temperature from the gas pre-treatment unit (max. 150 C) Power consumption: 80~100W/m. Pneumatic and electrical connectors for connection to the portable pre-treatment unit GAS 3000P COOLER * FEP is a modified PTFE (Teflon) type keeping PTFE properties: excellent heat resistance, chemical stability, dielectric constant, non-gas reactive and good mechanical resistance. The gas sampling probe GAS 3000P PROBE needs to be used with the portable gas sampling and pre-treatment unit GAS 3000P COOLER (the probe is powered by the portable GAS 3000P COOLER unit) 1. Sampling probe 2. High temperature steel pipe 3. Probe handle 4. Socket to heated hose 5. Temperature indication of sampling pipe 6. Power switch On/Off 7. 4-pin connector for 24 VDC power supply 8. Removable stainless steel filter 9. Adjustable flange 10. Flange fixing screw S - Type Pitot probe with thermocouple Delivered with : S-type Pitot probe for dynamic and differential pressure measurement. Thermocouple for flue gas temperature measurement. Material : stainless steel Probe insertion length : 1250 mm. KP factor : 0,85-0,87 2x 3m silicone pressure tubing with connector for connection to P+/P ports of the gas analyser 3m electrical cable for connection of the thermocouple to the Tgas port of the gas analyser

Portable gas pre-treatment unit GAS 3000 P COOLER 11 10 1 2 6 7 Combustion and emission processes usually involve wet and dust loaded gases that need to be pre-treated before being analysed by the flue gas analyser. The portable gas pre-treatment unit model GAS 3000P COOLER is dedicated for use in industrial environment and includes: A rough stainless steel enclosure with handle and rubber feet Peltier gas cooler (70W) with peristaltic pump Particulate filter down to 0.1µm Gas sampling pump (-350mbar @1L/min) with ON/OFF push-button Flow meter with needle valve Digital temperature controllers for heated line and Peltier gas cooler Internal forced ventilation Electrical and pneumatic connections Operational after max. 10 min (for Tamb = 25 C) 5 9 3 10 12 4 8 13 n Description 1 Thermostat cooler, factory setting +4 C 2 Thermostat heated line, Factory setting 150 C 3 Flowmeter 0-1.5L/min 4 Gas OUT 5 Push button for gas sampling pump activation 6 Gas IN (heated line connector) Max. gas inlet temperature: 180 C 7 Electrical connector for heating gas sampling line 8 Drain for continuous removal of condensate 9 Internal forced ventilation 10 Ventilation grids 11 Handle for gas cooler transportation 12 Particulate filter 0.1µm 13 Peltier gas cooler 70W, dew point +4 C ± 0.2 C (up to max. ambient temperature 40 C) 14 Metal plate heat exchanger gas cooler 15 Peristaltic pump 16 Gas sampling pump 1L/min @ 350 mbar suction pressure Non contractual ppictures and technical specifications. Products are subjected to modifications due to the constant evolution of applied technologies - Doc. Issue EN15v1 9 15 14 Portable NOx Converter GAS 3000P HNOX Measure of NO X (= NO + NO 2 ) by the NDIR NO detector after conversion of NO 2 into NO by an external catalytic converter. Well proved and largely diffused technology for the continue measure of NOx in industrial combustion applications (required when NO 2 content is > 5% of NOx). Conversion efficiency 95% * Gas flow rate: nominal 1L/min Converter temperature: adjustable from 390 C to 410 C Temperature regulation accuracy: ±1 C Ambient operating temperature: 5 C ~+50 C IN/OUT gas connectors: OD6mm Power supply: 220VAC 50Hz - 420W Integrated in a IP65 suitcase, weight : ± 6kg (*with new catalyticcartridge, @1L/min and 410 C) 16 G.E.I.T. EUROPE, 3380 Bunsbeek, Belgium, Phone: +32 472 666 465 - Email: sales@geiteurope.com - www.geiteurope.com