HOSTAFORM C POM Unfilled

Similar documents
HOSTAFORM C 9021 POM Unfilled

HOSTAFORM C POM Unfilled

HOSTAFORM C 9021 GV1/10 POM Glass Reinforced

HOSTAFORM C 9021 GV1/30 POM Glass Reinforced

HOSTAFORM C POM Unfilled

HOSTAFORM C 9021 GV1/30 POM Glass Reinforced

HOSTAFORM C 9021 SW POM Tribological

HOSTAFORM C /9005 POM Unfilled

VANDAR 2100 PBT Unfilled

CELANEX PBT Unfilled

CELANEX 1600A PBT Unfilled

VECTRA A150 LCP Glass Reinforced

HOSTAFORM C 9021 XAP POM Unfilled

FORTRON 6165A6 PPS Mineral / Glass Reinforced

VECTRA A430 LCP Specialty

CELCON M25 POM Unfilled

CELCON M25 POM Unfilled

FORTRON 1140L4 PPS Glass Reinforced

GUR 4120 PE-UHMW Unfilled

VECTRA MT1310 LCP Medical Technology

Bourns Sensors & Controls Division Announces Model 39 Material Change

DuPont Rynite 530 NC010

DuPont Rynite 545 NC010 (Preliminary Data)

DuPont Delrin 100ST NC010

DuPont Delrin 100 BK602

DuPont Delrin 500CL NC010

Property Test Condition Unit Standard typical Value -

DuPont Delrin. Delrin 111P NC010. Product Information. acetal resin. plastics.dupont.com

DuPont Zytel 408 NC010A

DuPont Delrin 100P NC010

Ultrason E 3010 NAT. Created: Source: Copyright M-Base Engineering+Software GmbH.

Property Test Condition Unit Standard typical Value -

Property Test Condition Unit Standard typical Value -

CAMPUS Datasheet. Ultramid B3EG3 - PA6-GF15 BASF

Celcon acetal copolymer Short Term Properties Brochure

Property Test Condition Unit Standard typical Value -

DuPont Delrin 100 NC010

DuPont Crastin S600F10 NC010

DuPont Zytel 70G43L NC010

Riteflex thermoplastic polyester elastomer Short Term Properties Brochure Riteflex

CAMPUS Datasheet. Ultramid A3X2G5 - PA66-GF25 FR BASF

DuPont Delrin 500AL NC010

LEXAN Resin LS2 Europe-Africa-Middle East: COMMERCIAL

DuPont Zytel 70G43L NC010

DuPont Delrin 150 NC010

DuPont Zytel 103HSL NC010

Lexan* Resin 241R Europe-Africa-Middle East: COMMERCIAL

DuPont Zytel 73G30L NC010

DuPont Zytel HTN51G50HSL BK083 (Preliminary Data)

DuPont Hytrel 3078 THERMOPLASTIC POLYESTER ELASTOMER PRODUCT INFORMATION. Product Information

DuPont Zytel 70G33L NC010

Cycoloy* Resin C2950 Europe-Africa-Middle East: COMMERCIAL

DuPont Zytel 101L NC010

VALOX Resin 451E Europe-Africa-Middle East: COMMERCIAL

DuPont Zytel 101F NC010

Makrolon. Product range Typical values

DuPont Delrin 100AL NC010

DuPont Delrin 500P BK602

DuPont Zytel 73G15HSL BK363

A3X2G7. Product Information Ultramid 07/2015 PA66-GF35 FR. BASF SE Ludwigshafen, Germany

Valox* Resin 357X Europe-Africa-Middle East: COMMERCIAL

DuPont Zytel 103HSL NC010

DuPont Hytrel 7246 THERMOPLASTIC POLYESTER ELASTOMER PRODUCT INFORMATION. Product Information

DuPont Minlon 10B40 NC010

Noryl* Resin GFN1630V Europe-Africa-Middle East: COMMERCIAL

DuPont Zytel 70G30L NC010

DuPont Hytrel 4069 THERMOPLASTIC POLYESTER ELASTOMER PRODUCT INFORMATION. Product Information

Valox* Resin 310SE0 Asia Pacific: COMMERCIAL

Grilamid LBV-50H FWA black 9225 EMS-GRIVORY a unit of EMS-CHEMIE AG

Cycoloy* Resin C2800 Europe-Africa-Middle East: COMMERCIAL

DuPont Hytrel DYM350BK

DuPont Zytel 70G35HSLRA4 BK267

DuPont Zytel 103FHS NC010

Noryl* Resin SE1GFN1 Europe-Africa-Middle East: COMMERCIAL

DuPont Hytrel. Hytrel Product Information. thermoplastic polyester elastomer. plastics.dupont.com

Last Updated: August, / 5

Lexan* Resin EXL9112 Americas: COMMERCIAL

DuPont Minlon 73M40 NC010

Amodel AS-1133 HS. polyphthalamide. Technical Data Sheet

Makrolon 2205 and 2207

SABIC PC Resin PC0703R Asia Pacific: COMMERCIAL

Ultrason E, S, P (PESU, PSU, PPSU) Product Range

DuPont Hytrel 4068FG (Preliminary Data)

Lexan* Resin 500ECR Americas: COMMERCIAL

Grilon TSG-30/4 EMS-GRIVORY a unit of EMS-CHEMIE AG

A3XZG5. Product Information Ultramid 11/2017 PA66-I GF25 FR(52) BASF SE Ludwigshafen, Germany

FORTRON PPS POLYPHENYLENE SULFIDE (PPS) Short-Term Properties Guide

DuPont Zytel 70G33HS1L BK031

Product range Typical values

Physical Dry Conditioned Unit Test method

LEXAN Resin 121R Asia Pacific: COMMERCIAL

DuPont Zytel 8018HS NC010

DuPont Zytel 70G30HSLR NC010

Noryl* Resin V0150B Europe-Africa-Middle East: COMMERCIAL

Ixef Technical Data. polyarylamide

Lexan* Resin DMX2415 Americas: COMMERCIAL

Grilamid TR 55 EMS-GRIVORY a unit of EMS-CHEMIE AG

DuPont Zytel 70G30HSLR BK099

Commercial: Active Africa & Middle East Asia Pacific Glass Fiber, 50% Filler by Weight Flame Retardant. Physical Typical Value Unit Test method

TECHNYL A 205F. Key Properties. Description. Benefits. Applications. Product Data Sheet. Regional Availability

Transcription:

Description Chemical abbreviation according to ISO 1043-1: POM Molding compound ISO 9988- POM-K, M-GNR, 04-002 POM copolymer Easy flowing Injection molding type like C 13021, but with higher strength, rigidity and hardness over the entire permissible temperature range for HOSTAFORM; good chemical resistance to solvents, fuel and strong alkalis as well as good hydrolysis resistance; high resistance to thermal and oxidative degradation. FFulfils EG-directive 2002/72/EU as well as the recommendation XXXIII for consumer goods of the BgVV, corresponding to FDA-regulation for food contact. UL-registration for all colours and a thickness more than 1.5 mm as UL 94 HB; burning rate ISO 3795 and FMVSS 302 < 75 mm/min for a thickness more than 1 mm. Ranges of applications: For molded parts with higher requirements to strength, rigidity und hardness, ranges of applications with fuel contact. FDA = Food and Drug Administration (USA) BgVV = Bundesinstitut f r gesundheitlichen Verbraucherschutz und Veterin rmedizin UL = Underwriters Laboratories (USA) FMVSS = Federal Motor Vehicle Safety Standard (USA) Physical properties Value Unit Test Standard Density 1410 kg/m³ ISO 1183 Melt volume rate (MVR) 12 cm³/10min ISO 1133 MVR test temperature 190 C ISO 1133 MVR test load 2.16 kg ISO 1133 Mold shrinkage - parallel 2 % ISO 294-4 Mold shrinkage - normal 1.8 % ISO 294-4 Water absorption (23 C-sat) 0.65 % ISO 62 Humidity absorption (23 C/50%RH) 0.2 % ISO 62 Mechanical properties Value Unit Test Standard Tensile modulus (1mm/min) 3050 MPa ISO 527-2/1A Tensile stress at yield (50mm/min) 68 MPa ISO 527-2/1A Tensile strain at yield (50mm/min) 8 % ISO 527-2/1A Nominal strain at break (50mm/min) 20 % ISO 527-2/1A Tensile creep modulus (1h) 2750 MPa ISO 899-1 Tensile creep modulus (1000h) 1450 MPa ISO 899-1 Charpy impact strength @ 23 C 120 kj/m² ISO 179/1eU Charpy impact strength @ -30 C 120 kj/m² ISO 179/1eU Charpy notched impact strength @ 23 C 6.7 kj/m² ISO 179/1eA Charpy notched impact strength @ -30 C 6 kj/m² ISO 179/1eA Page: 1 WWW.C9021.COM

Thermal properties Value Unit Test Standard Melting temperature (10 C/min) 170 C ISO 11357-1,-2,-3 DTUL @ 1.8 MPa 107 C ISO 75-1/-2 Vicat softening temperature B50 (50 C/h 50N) 158 C ISO 306 Coeff.of linear therm. expansion (parallel) 1.1 E-4/ C ISO 11359-2 Flammability @1.6mm nom. thickn. HB class UL94 thickness tested (1.6) 1.5 mm UL94 UL recognition (1.6) UL - UL94 Flammability at thickness h HB class UL94 thickness tested (h) 3 mm UL94 UL recognition (h) UL - UL94 Electrical properties Value Unit Test Standard Relative permittivity - 100 Hz 4 - IEC 60250 Relative permittivity - 1 MHz 4 - IEC 60250 Dissipation factor - 100 Hz 20 E-4 IEC 60250 Dissipation factor - 1 MHz 50 E-4 IEC 60250 Volume resistivity 1E12 Ohm*m IEC 60093 Surface resistivity 1E14 Ohm IEC 60093 Electric strength 35 kv/mm IEC 60243-1 Comparative tracking index CTI 600 - IEC 60112 Test specimen production Value Unit Test Standard Processing conditions acc. ISO 9988 - Internal Injection molding melt temperature 205 C ISO 294 Injection molding mold temperature 90 C ISO 294 Injection molding flow front velocity 200 mm/s ISO 294 Injection molding hold pressure 90 MPa ISO 294 Stress-strain Secant modulus-strain Page: 2

Stress-strain (isochronous) Creep modulus-time Typical injection moulding processing conditions Maximum residual moisture content: 0.1500% Processing Temperatures: Cavity Melt Hot Runner Die 4 3 2 1 Feeding Hopper min ( C) 80 190 190 190 190 190 180 170 60 20 max ( C) 120 210 210 210 210 200 190 180 80 30 Processing Pressures: Injection Pressure Holding Pressure Back Pressure min (bar) 600 600 0 max (bar) 1200 1200 40 Page: 3

Injection speed: slow - medium Screw speed: Screw diameter (mm) 25 40 55 Screw speed (rpm) 120 100 70 Pre-drying conditions: It is normally not necessary to dry HOSTAFORM. However, should there be surface moisture (condensate) on the molding compound as a result of incorrect storage, drying is required. A circulating air drying cabinet can be used for this purpose if the granul The product can then be stored in standard conditions until processed. Drying time: 3-4 h Drying temperature: 120-140 C Special information: No special information available. Injection Molding Standard injection moulding machines with three phase (15 to 25 D) plasticating screws will fit. Melt temperature 190-230 C Mould temperature 60-120 C Contact Information Americas Ticona Product Information Service 8040 Dixie Highway Florence, KY 41042 USA Tel.: +1-800-833-4882 Tel.: +1-859-372-3244 Europe Ticona GmbH Information Service Tel.: +49 (0) 180-5842662 (Germany)* +49 (0) 69-30516299 (Europe) Fax: +49 (0) 180-2021202 (Germany & Europe)** *starting 01.01.2007 0,14 /minute + local landline rates **0,06 /Call + local landline rates Customer Service Tel.: +1-800-526-4960 Tel.: +1-859-372-3214 Fax: +1-859-372-3125 Page: 4

General Disclaimer NOTICE TO USERS: Values shown are based on testing of laboratory test specimens and represent data that fall within the standard range of properties for natural material. These values alone do not represent a sufficient basis for any part design and are not intended for use in establishing maximum, minimum, or ranges of values for specification purposes. Colorants or other additives may cause significant variations in data values. Properties of molded parts can be influenced by a wide variety of factors including, but not limited to, material selection, additives, part design, processing conditions and environmental exposure. Any determination of the suitability of a particular material and part design for any use contemplated by the users and the manner of such use is the sole responsibility of the users, who must assure themselves that the material as subsequently processed meets the needs of their particular product or use. To the best of our knowledge, the information contained in this publication is accurate; however, we do not assume any liability whatsoever for the accuracy and completeness of such information. The information contained in this publication should not be construed as a promise or guarantee of specific properties of our products. It is the sole responsibility of the users to investigate whether any existing patents are infringed by the use of the materials mentioned in this publication. Moreover, there is a need to reduce human exposure to many materials to the lowest practical limits in view of possible adverse effects. To the extent that any hazards may have been mentioned in this publication, we neither suggest nor guarantee that such hazards are the only ones that exist. We recommend that persons intending to rely on any recommendation or to use any equipment, processing technique or material mentioned in this publication should satisfy themselves that they can meet all applicable safety and health standards. We strongly recommend that users seek and adhere to the manufacturer s current instructions for handling each material they use, and entrust the handling of such material to adequately trained personnel only. Please call the telephone numbers listed (+49 (0) 69 30516299 for Europe and +1 859-372-3244 for the Americas) for additional technical information. Call Customer Services for the appropriate Materials Safety Data Sheets (MSDS) before attempting to process our products. The products mentioned herein are not intended for use in medical or dental implants. Copyright 2007, Ticona, all rights reserved. (Pub. 23-Mar-2007) Page: 5